G3VM-351GL

G3VM-351GL

  • 厂商:

    OMRON(欧姆龙)

  • 封装:

    SOP-4

  • 描述:

    1 FORM A(SPSTNO) 负载AC,DC 负载电压350V

  • 数据手册
  • 价格&库存
G3VM-351GL 数据手册
G3VM-351GL MOS FET Relays SOP Current-limiting Relays in 350-V Load Voltage Series. • G3VM-351G with current limiting. • Current limit: 150 to 300 mA RoHS compliant Note: The actual product is marked differently from the image shown here. ■ Application Examples ■ Terminal Arrangement/Internal Connections 4 • Communication equipment 3 Mold pin mark * • Test & Measurement equipment OMRON logo 932 Pin 1 mark 1 Model name LOT.No. 2 Note: The actual product is marked differently from the image shown here. * The indentation in the corner diagonally opposite from the pin 1 mark is from a pin on the mold. ■ List of Models Package type Contact form 1a (SPST-NO) SOP4 Load voltage (peak value) * Terminals Surface-mounting Terminals Model G3VM-351GL 350 V G3VM-351GL (TR) Minimum package quantity Current limit Number per tube Number per tape and reel Available 100 - - 2,500 * The AC peak and DC value are given for the load voltage. ■ Absolute Maximum Ratings (Ta = 25°C) Output Input Item LED forward current Repetitive peak LED forward current LED forward current reduction rate LED reverse voltage Connection temperature Load voltage (AC peak/DC) Continuous load current (AC peak/DC) ON current reduction rate Connection temperature Dielectric strength between I/O (See note 1.) Ambient operating temperature Ambient storage temperature Soldering temperature Symbol IF IFP ∆IF/°C VR TJ VOFF IO ∆IO/°C TJ Rating 50 1 −0.5 5 125 350 120 −1.2 125 Unit mA A mA/°C V °C V mA mA/°C °C VI-O 1500 Vrms Ta Tstg - −40 to +85 −55 to +125 260 °C °C °C Measurement conditions 100 µs pulses, 100 pps Ta ≥ 25°C Ta ≥ 25°C AC for 1 min With no icing or condensation With no icing or condensation 10 s Note: 1. The dielectric strength between the input and output was checked by applying voltage between all pins as a group on the LED side and all pins as a group on the light-receiving side. ■ Electrical Characteristics (Ta = 25°C) Item Symbol Minimum Typical Maximum Unit Measurement conditions Note: 2. Turn-ON and Turn-OFF Times VF 1.0 1.15 1.3 V IF = 10 mA 1 4 Reverse current IR - - 10 µA VR = 5 V 2 3 AC/DC Capacity between terminals CT - 30 - pF V = 0, f = 1 MHz Trigger LED forward current IFT - 1 3 mA IO = 120 mA 1 4 Maximum resistance with output ON RON - 15 35 Ω 3 Current leakage when the relay is open ILEAK - - 1.0 µA 2 VOFF = 350 V Capacity between terminals COFF - 70 - pF V = 0, f = 1 MHz Limit current ILIM 150 - 300 mA IF = 5 mA, VDD = 5 V, t = 5 ms Capacity between I/O terminals CI-O - 0.8 - pF f = 1 MHz, VS = 0 V Insulation resistance between I/O terminals RI-O 1000 - - MΩ VI-O = 500 VDC, ROH ≤ 60 % Turn-ON time tON - 0.3 1.0 ms Turn-OFF time tOFF - 0.1 1.0 ms IF = 5 mA, RL = 200 Ω, VDD = 20 V (See note 2.) Output Input LED forward voltage 1 IF = 5 mA, IO = 120 mA IF Load RL VDD VOUT IF VOUT 10% t ON 90% t OFF G3VM-351GL MOS FET Relays ■ Recommended Operating Conditions Use the G3VM under the following conditions so that the Relay will operate properly. Item Symbol Minimum Typical Maximum Unit Load voltage (AC peak/DC) Operating LED forward current Continuous load current (AC peak/DC) Ambient operating temperature VDD IF IO Ta 5 −20 7.5 - 280 25 100 65 V mA mA °C ■ Engineering Data LED forward current vs. Ambient temperature Continuous load current vs. Ambient temperature IO - Ta 100 80 60 40 20 0 -20 0 20 40 60 80 100 200 160 120 0 20 40 60 80 100 On-state resistance vs. Ambient temperature RON - Ta 30 20 20 40 80 tOFF 100 30 10 3 10 30 100 300 IO = 120 mA t < 1s 4 3 2 1 -20 0 20 40 60 80 100 Ambient temperature Ta (°C) Current leakage vs. Ambient temperature tON, tOFF - Ta ILEAK - Ta 3000 1000 tON 300 100 VOFF = 350 V 30 10 3 100 1 tOFF 30 VDD = 20 V RL = 200 Ω IF = 5 mA tON 1 100 Current leakage ILEAK (nA) 300 1.8 5 Ambient temperature Ta (°C) Turn ON, Turn OFF time tON, tOFF (µs) Ta = 25 °C VDD = 20 V RL = 200 Ω 1000 60 Turn ON, Turn OFF time vs. Ambient temperature tON, tOFF - IF 1.6 0 0 On-state voltage VON (V) 3000 1.4 IFT - Ta IO = 120 mA IF = 5 mA t < 1s 40 1.2 Trigger LED forward current vs. Ambient temperature 50 -20 2 Turn ON, Turn OFF time vs. LED forward current 1 LED forward voltage VF (V) 0 1 -2 0.8 Ambient temperature Ta (°C) -200 Turn ON, Turn OFF time tON, tOFF (µs) 0.6 120 10 -1 3 0.1 0 -100 -2 10 0.3 Trigger LED forward current IFT (mA) 100 30 40 -20 On-state resistance RON (Ω) Continuous load current IO (mA) IO - VON Ta = 25 °C IF = 5 mA Ta = 25 °C 1 Ambient temperature Ta (°C) 200 100 80 0 120 Continuous load current vs. On-state voltage IF - VF 240 LED forward current IF (mA) Continuous load current IO (mA) LED forward current IF (mA) IF - Ta LED forward current vs. LED forward voltage 10 -20 0.3 0.1 0 LED forward current IF (mA) 20 40 60 80 100 Ambient temperature Ta (°C) -20 0 20 40 60 80 100 Ambient temperature Ta (°C) ■ Safety Precautions • Refer to "Common Precautions" for all G3VM models. 2 Appearance/Dimensions SOP4 type ■ Appearance SOP (Small Outline Package) SOP4 Mold pin mark * OMRON logo Pin 1 mark 932 Model name LOT.No. Note: The actual product is marked differently from the image shown here. * The indentation in the corner diagonally opposite from the pin 1 mark is from a pin on the mold. ■ Dimensions (Unit: mm) Surface-mounting Terminals Actual Mounting Pad Dimensions Weight: 0.1 g 4.4±0.25 3.9±0.2 (Recommended Value, TOP VIEW) 2.1 max. 6 to 6.3 0.15 0.4±0.1 0.1±0.1 1.2 0.6±0.3 7.0±0.4 2.54±0.25 Note: The actual product is marked differently from the image shown here. 0.8 2.54 • Application examples provided in this document are for reference only. In actual applications, confirm equipment functions and safety before using the product. • Consult your OMRON representative before using the product under conditions which are not described in the manual or applying the product to nuclear control systems, railroad systems, aviation systems, vehicles, combustion systems, medical equipment, amusement machines, safety equipment, and other systems or equipment that may have a serious influence on lives and property if used improperly. Make sure that the ratings and performance characteristics of the product provide a margin of safety for the system or equipment, and be sure to provide the system or equipment with double safety mechanisms. Note: Do not use this document to operate the Unit. OMRON Corporation ELECTRONIC AND MECHANICAL COMPONENTS COMPANY Contact: www.omron.com/ecb Cat. No. K235-E1-01 0412(0412)(O)
G3VM-351GL 价格&库存

很抱歉,暂时无法提供与“G3VM-351GL”相匹配的价格&库存,您可以联系我们找货

免费人工找货
G3VM-351GL
  •  国内价格 香港价格
  • 1+26.901291+3.48040
  • 5+20.175975+2.61030
  • 25+18.8658425+2.44080
  • 100+17.81774100+2.30520
  • 400+16.59496400+2.14700

库存:0

G3VM-351GL
    •  国内价格 香港价格
    • 1+36.077431+4.66758
    • 5+32.451435+4.19846
    • 10+27.2821110+3.52967
    • 30+23.8386530+3.08417
    • 50+23.1499650+2.99507
    • 100+22.62722100+2.92744
    • 200+22.37000200+2.89416

    库存:100

    G3VM-351GL
      •  国内价格 香港价格
      • 1+36.077431+4.66758
      • 5+32.451435+4.19846
      • 10+27.2821110+3.52967
      • 30+23.8386530+3.08417
      • 50+23.1499650+2.99507
      • 100+22.62722100+2.92744
      • 200+22.37000200+2.89416

      库存:10