G3VM-352J
MOS FET Relays
Two Channels and an 8-pin SOP Package
in 350-V Load Voltage Series.
• Thin Mini Flat Type and Small Outline Package MOS FET Relay with a Height
of 2.1 mm, Incorporating a MOS FET Optically Coupled with an Infrared LED
• Continuous load current of 110 mA.
RoHS compliant
Note: The actual product is marked differently from the
image shown here.
■ Application Examples
■ Terminal Arrangement/Internal
Connections
• Semiconductor test equipment
• Test & Measurement equipment
8
7
6
5
• Communication equipment
OMRON logo
• Data loggers
Pin 1 mark
1
2
3
Model
name
LOT.No.
932
4
Note: The actual product is marked differently from the image shown here.
■ List of Models
Package type Contact form
SOP8
2a
(DPST-NO)
Load voltage
(peak value) *
Terminals
Surface-mounting Terminals
350 V
Model
G3VM-352J
G3VM-352J (TR)
Minimum package quantity
Number per tube Number per tape and reel
50
-
-
2,500
* The AC peak and DC value are given for the load voltage.
■ Absolute Maximum Ratings (Ta = 25°C)
Output
Input
Item
LED forward current
LED forward current reduction rate
LED reverse voltage
Connection temperature
Load voltage (AC peak/DC)
Continuous load current (AC peak/DC)
ON current reduction rate
Dielectric strength between
I/O (See note 1.)
Ambient operating temperature
Ambient storage temperature
Soldering temperature
Symbol
IF
∆IF/°C
VR
TJ
VOFF
IO
∆IO/°C
Rating
50
−0.5
5
125
350
110
−1.1
Unit
mA
mA/°C
V
°C
V
mA
mA/°C
Measurement conditions
Ta ≥ 25°C
VI-O
1500
Vrms
AC for 1 min
Ta
Tstg
-
−40 to +85
−55 to +125
260
°C
°C
°C
Ta ≥ 25°C
With no icing or condensation
With no icing or condensation
10 s
Note: 1. The dielectric strength between the input and
output was checked by applying voltage
between all pins as a group on the LED side and
all pins as a group on the light-receiving side.
■ Electrical Characteristics (Ta = 25°C)
Output
Input
Item
Symbol Minimum Typical Maximum
LED forward voltage
VF
1.0
1.15
1.3
Reverse current
IR
10
Capacity between terminals
CT
30
Trigger LED forward current
IFT
1
3
25
35
Maximum resistance
RON
with output ON
35
50
Current leakage when the relay is open
ILEAK
1.0
Capacity between terminals COFF
30
Capacity between I/O terminals
CI-O
0.8
Insulation resistance between I/O terminals
RI-O
1000
Turn-ON time
tON
0.3
1
Turn-OFF time
tOFF
0.1
1
1
Unit
V
µA
pF
mA
Ω
Ω
µA
pF
pF
MΩ
ms
ms
Measurement conditions
IF = 10 mA
Note: 2. Turn-ON and Turn-OFF Times
VR = 5 V
IF 1 (3)
V = 0, f = 1 MHz
8 (6) RL
VDD
IO = 110 mA
VOUT
2 (4)
7 (5)
IF = 5 mA, IO = 110 mA, t < 1 s
IF = 5 mA, IO = 110 mA
VOFF = 350 V
V = 0, f = 1 MHz
IF
f = 1 MHz, VS = 0 V
VI-O = 500 VDC, ROH ≤ 60 %
90%
VOUT
10%
IF = 5 mA, RL = 200 Ω ,
t ON
t OFF
VDD = 20 V (See note 2.)
G3VM-352J
MOS FET Relays
■ Recommended Operating Conditions
Use the G3VM under the following conditions so that the Relay will operate properly.
Item
Symbol
Minimum
Typical
Maximum
Load voltage (AC peak/DC)
VDD
-
-
280
Unit
V
Operating LED forward current
IF
5
10
25
mA
Continuous load current (AC peak/DC)
IO
-
-
100
mA
Ambient operating temperature
Ta
−20
-
65
°C
■ Engineering Data
LED forward current vs. Ambient
temperature
Continuous load current vs. Ambient
temperature
IO - Ta
80
60
40
20
200
160
120
0
20
40
60
80
100
0
-20
0
20
40
80
100
0.1
120
On-state resistance vs. Ambient
temperature
0.6
IO = 110 mA
IF = 5 mA
t < 1s
40
30
20
1
2
3
Turn ON, Turn OFF time vs. LED
forward current
0
20
40
60
80
100
Turn ON, Turn OFF time vs. Ambient
temperature
300
tOFF
100
30
1000
tON
300
100
10
2
1
0
30
100
300
20
40
60
80
100
Ambient temperature Ta (°C)
Current leakage vs. Ambient
temperature
100
VOFF = 350 V
30
10
3
tOFF
1
30
VDD = 20 V
RL = 200 Ω
IF = 5 mA
0.3
10
10
5
3
ILEAK - Ta
3000
tON
3
4
-20
Current leakage ILEAK (nA)
Turn ON, Turn OFF time tON, tOFF (µs)
VDD = 20 V
RL = 200 Ω
1000
1.8
IO = 110 mA
t < 1s
tON, tOFF - Ta
Ta = 25°C
1.6
5
Ambient temperature Ta (°C)
tON, tOFF - IF
3000
1.4
0
-20
4
On-state voltage VON (V)
1
1.2
IFT - Ta
50
0
-200
0
1
Trigger LED forward current vs.
Ambient temperature
10
1
0.8
LED forward voltage VF (V)
Trigger LED forward current IFT (mA)
-100
Turn ON, Turn OFF time tON, tOFF (µs)
60
Ambient temperature Ta (°C)
On-state resistance RON (Ω)
Continuous load current IO (mA)
0
-2
3
RON - Ta
100
-3
10
0.3
120
Ta = 25°C
IF = 5 mA
-4
30
40
IO - VON
200
Ta = 25°C
1
Ambient temperature Ta (°C)
Continuous load current vs. On-state
voltage
100
80
0
-20
IF - VF
240
LED forward current IF (mA)
100
Continuous load current IO (mA)
LED forward current IF (mA)
IF - Ta
LED forward current vs. LED forward
voltage
0.1
-20
0
LED forward current IF (mA)
20
40
60
80
100
Ambient temperature Ta (°C)
-20
0
20
40
60
80
100
Ambient temperature Ta (°C)
■ Safety Precautions
• Refer to "Common Precautions" for all G3VM models.
2
Appearance/Dimensions
SOP8 type
■ Appearance
SOP (Small Outline Package)
SOP8
OMRON logo
Pin 1 mark
932
Model name
LOT.No.
Note: The actual product is marked differently from the image shown here.
■ SOP8
(Unit: mm)
Surface-mounting Terminals
Actual Mounting Pad
Dimensions
Weight: 0.2 g
(Recommended Value, TOP VIEW)
4.4±0.2
2.1 max.
9.4±0.25
6 to 6.3
1.2
0.15
0.8
2.54±0.25
0.1±0.1
0.4±0.1
0.5±0.3
7.0±0.4
2.54
2.54
Note: The actual product is marked differently from the image shown here.
• Application examples provided in this document are for reference only. In actual applications, confirm equipment functions and safety before using the product.
• Consult your OMRON representative before using the product under conditions which are not described in the manual or applying the product to nuclear control systems, railroad
systems, aviation systems, vehicles, combustion systems, medical equipment, amusement machines, safety equipment, and other systems or equipment that may have a serious
influence on lives and property if used improperly. Make sure that the ratings and performance characteristics of the product provide a margin of safety for the system or
equipment, and be sure to provide the system or equipment with double safety mechanisms.
Note: Do not use this document to operate the Unit.
OMRON Corporation
ELECTRONIC AND MECHANICAL COMPONENTS COMPANY
Contact: www.omron.com/ecb
Cat. No. K167-E1-01
0412(0412)(O)
很抱歉,暂时无法提供与“G3VM-352J(TR)”相匹配的价格&库存,您可以联系我们找货