G3VM-401BY/EY
MOS FET Relays
Analog-switching MOS FET Relays with
a Dielectric Strength of 5 kVAC between
I/O Using Optical Isolation.
• Switches minute analog signals.
• Leakage current of 1 µA max. when output relay is open.
RoHS compliant
Note: The actual product is marked differently from the
image shown here.
■ Application Examples
■ Terminal Arrangement/Internal Connections
• Communication equipment
6
5
4
• Test & Measurement equipment
OMRON logo
Model name
• Industrial equipment
932
Pin 1 mark
1
LOT.NO.
3
2
Note: The actual product is marked differently from the image shown here.
■ List of Models
Package type Contact form
Load voltage
(peak value) *
Terminals
PCB Terminals
DIP6
1a
(SPST-NO)
Model
Minimum package quantity
Number per tube Number per tape and reel
G3VM-401BY
400 V
Surface-mounting Terminals
G3VM-401EY
G3VM-401EY (TR)
50
-
-
1,500
* The AC peak and DC value are given for the load voltage.
■ Absolute Maximum Ratings (Ta = 25°C)
Output
Input
Item
LED forward current
Repetitive peak LED forward current
LED forward current reduction rate
LED reverse voltage
Connection temperature
Load voltage (AC peak/DC)
Connection A
Continuous
Connection B
load current
Connection C
Connection A
ON current
reduction
Connection B
rate
Connection C
Connection temperature
Dielectric strength between I/O (See note 1.)
Ambient operating temperature
Ambient storage temperature
Soldering temperature
Symbol
IF
IFP
∆IF/°C
VR
TJ
VOFF
IO
∆IO/°C
TJ
VI-O
Ta
Tstg
-
Rating
50
1
−0.5
5
125
400
120
120
240
−1.2
−1.2
−2.4
125
5000
−40 to +85
−55 to +125
260
Unit
mA
A
mA/°C
V
°C
V
mA
mA/°C
°C
Vrms
°C
°C
°C
Measurement conditions
100 µs pulses, 100 pps
Ta ≥ 25°C
Note: 1. The dielectric strength between the input and output was
checked by applying voltage between all pins as a group on
the LED side and all pins as a group on the light-receiving side.
Connection Diagram
Connection A
Connection A: AC peak/DC
Connection B and C: DC
Ta ≥ 25°C
AC for 1 min
With no icing or condensation
With no icing or condensation
10 s
Connection B
Connection C
1
6
Load
2
5
3
4
or AC
DC
1
6
2
5
3
4
1
6
2
5
3
4
■ Electrical Characteristics (Ta = 25°C)
Output
Input
Item
Symbol Minimum Typical Maximum
LED forward voltage
VF
1.0
1.15
1.3
Reverse current
IR
10
Capacity between terminals
CT
30
Trigger LED forward current
IFT
3
Connection A
17
35
Maximum
resistance
Connection B
RON
11
20
with output ON Connection C
6
10
Current leakage when the relay is open
ILEAK
1.0
Capacity between terminals COFF
40
Capacity between I/O terminals
CI-O
0.8
Insulation resistance between I/O terminals
RI-O
1000
Turn-ON time
tON
0.3
1.0
Turn-OFF time
tOFF
0.1
1.0
1
Unit
V
µA
pF
mA
Ω
Ω
Ω
µA
pF
pF
MΩ
ms
ms
Measurement conditions
IF = 10 mA
VR = 5 V
Note: 2. Turn-ON and Turn-OFF Times
V = 0, f = 1 MHz
IF 1
6 RL
IO = 120 mA
VDD
VOUT
IF = 5 mA, IO = 120 mA
2
4
IF = 5 mA, IO = 120 mA
IF = 5 mA, IO = 240 mA
VOFF = 400 V
V = 0, f = 1 MHz
IF
f = 1 MHz, VS = 0 V
VI-O = 500 VDC, ROH ≤ 60%
90%
VOUT
10%
IF = 5 mA, RL = 200 Ω,
t ON
t OFF
VDD = 20 V(See note 2.)
Load
DC
Load
DC
G3VM-401BY/EY
MOS FET Relays
■ Recommended Operating Conditions
Use the G3VM under the following conditions so that the Relay will operate properly.
Item
Symbol
Minimum
Typical
Maximum
Load voltage (AC peak/DC)
VDD
-
-
320
Unit
V
Operating LED forward current
IF
5
7.5
25
mA
Continuous load current (AC peak/DC)
IO
-
-
120
mA
Ambient operating temperature
Ta
−20
-
65
°C
■ Engineering Data
Continuous load current vs. Ambient
temperature
80
60
40
300
-20
0
20
40
60
80
100
Connection C
250
200
150
20
0
Connection A and B
50
0.3
-20
0
20
40
60
80
100
On-state resistance vs. Ambient
temperature
0.6
0
IF = 5mA
IO = 120mA
25
20
15
0
1
2
-20
0
20
40
60
80
1.5
1.0
-40
-20
0
tON
10
tON
VDD = 20V, IF = 5mA
100
100
80
100
100
VOFF = 400V
10
1
tOFF
10
10
60
Current leakage vs. Ambient
temperature
Current leakage ILEAK (nA)
Turn ON, Turn OFF time tON, tOFF (µs)
tOFF
40
ILEAK - Ta
1000
RL = 200Ω
20
Ambient temperature Ta (°C)
tON, tOFF - Ta
VDD = 10V, Ta = 25°C
1.8
IO = 120mA
Ambient temperature Ta (°C)
tON, tOFF - IF
RL = 200Ω
1.6
2.0
100
Turn ON, Turn OFF time vs. Ambient
temperature
1000
1.4
0.5
-40
On-state voltage VON (V)
Turn ON, Turn OFF time vs. LED
forward current
1.2
LED forward voltage VF (V)
10
1
1
IFT - Ta
30
-40
100
0.8
Trigger LED forward current vs.
Ambient temperature
-80
Turn ON, Turn OFF time tON, tOFF (µs)
0.1
120
Trigger LED forward current IFT (mA)
40
-1
3
Ambient temperature Ta (°C)
On-state resistance RON (Ω)
Continuous load current IO (mA)
IF = 5mA,
Ta = 25°C
80
-2
10
RON - Ta
IO - VON
-120
Ta = 25°C
30
1
Ambient temperature Ta (°C)
120
100
100
0
120
Continuous load current vs. On-state
voltage
IF - VF
IO - Ta
Continuous load current IO (mA)
LED forward current IF (mA)
IF - Ta
100
LED forward current vs. LED forward
voltage
LED forward current IF (mA)
LED forward current vs. Ambient
temperature
0.1
-40
-20
LED forward current IF (mA)
0
20
40
60
80
100
Ambient temperature Ta (°C)
20
40
60
80
100
Ambient temperature Ta (°C)
■ Safety Precautions
• Refer to "Common Precautions" for all G3VM models.
2
Appearance/Dimensions
DIP6 type
■ Appearance
DIP (Dual Inline Package)
DIP6
OMRON logo
Model name
932
Pin 1 mark
LOT.NO.
Note: The actual product is marked differently from the image shown here.
■ Dimensions
(Unit:mm)
PCB Terminals
Surface-mounting Terminals
Weight: 0.4 g
Weight: 0.4 g
PCB Dimensions (BOTTOM VIEW)
Six, 0.8-dia. holes
2.54
(0.61)
2.54
7.12±0.25
7.12±0.25
6.4±0.25
(0.61)
(1.52)
(1.52)
6.4±0.25
Actual Mounting Pad Dimensions
7.62±0.25
0.8±0.25
7.62±0.25
(Recommended Value, TOP VIEW)
3.65 +0.15
−0.25
0.25 +0.1
−0.05
2.5 min.
1.2±0.15
0.5±0.1
2.54±0.25
3.65 +0.15
−0.25
4.0 +0.25
−0.2
2.54
2.54
1.0 min.
7.85 to 8.80
1.2±0.15
2.54±0.25
Note: The actual product is marked differently from the
image shown here.
1.0 min.
10.0 max.
8.3 to 8.8
1.3
1.5
• Application examples provided in this document are for reference only. In actual applications, confirm equipment functions and safety before using the product.
• Consult your OMRON representative before using the product under conditions which are not described in the manual or applying the product to nuclear control systems, railroad
systems, aviation systems, vehicles, combustion systems, medical equipment, amusement machines, safety equipment, and other systems or equipment that may have a serious
influence on lives and property if used improperly. Make sure that the ratings and performance characteristics of the product provide a margin of safety for the system or
equipment, and be sure to provide the system or equipment with double safety mechanisms.
Note: Do not use this document to operate the Unit.
OMRON Corporation
ELECTRONIC AND MECHANICAL COMPONENTS COMPANY
Contact: www.omron.com/ecb
Cat. No. K220-E1-01
0412(0412)(O)
很抱歉,暂时无法提供与“G3VM-401EY”相匹配的价格&库存,您可以联系我们找货
免费人工找货