G3VM-401H
MOS FET Relays
MOS FET Relays Designed for Switching
Minute Signals and Analog Signals.
• Continuous load current of 120 mA.
RoHS compliant
Note: The actual product is marked differently from the
image shown here.
■ Application Examples
■ Terminal Arrangement/Internal Connections
6
• Communication equipment
5
4
• Test & Measurement equipment
OMRON logo
• Data loggers
Model name
932
Pin 1 mark
• Amusement equipment
1
LOT.No.
3
2
Note: The actual product is marked differently from the image shown here.
■ List of Models
Package type Contact form
SOP6
1a
(SPST-NO)
Load voltage
(peak value) *
Terminals
Surface-mounting Terminals
400 V
Model
Minimum package quantity
Number per tube Number per tape and reel
G3VM-401H
G3VM-401H (TR)
75
-
-
2,500
* The AC peak and DC value are given for the load voltage.
■ Absolute Maximum Ratings (Ta = 25°C)
Output
Input
Item
LED forward current
Repetitive peak LED forward current
LED forward current reduction rate
LED reverse voltage
Connection temperature
Load voltage (AC peak/DC)
Connection A
Continuous
Connection B
load current
Connection C
Connection A
ON current
Connection B
reduction
rate
Connection C
Connection temperature
Dielectric strength between
I/O (See note 1.)
Ambient operating temperature
Ambient storage temperature
Soldering temperature
Symbol
IF
IFP
∆IF/°C
VR
TJ
VOFF
Rating
50
1
−0.5
5
125
400
120
120
240
−1.2
−1.2
−2.4
125
Unit
mA
A
mA/°C
V
°C
V
VI-O
1500
Vrms
Ta
Tstg
-
−40 to +85
−55 to +125
260
°C
°C
°C
IO
∆IO/°C
TJ
Measurement conditions
100 µs pulses, 100 pps
Ta ≥ 25°C
Note: 1. The dielectric strength between the input and output was
checked by applying voltage between all pins as a group on
the LED side and all pins as a group on the light-receiving side.
Connection Diagram
Connection A
mA
mA/°C
Connection A: AC peak/DC
Connection B and C: DC
Ta ≥ 25°C
Connection B
°C
AC for 1 min
With no icing or condensation
With no icing or condensation
10 s
Connection C
1
6
2
5
3
4
1
6
2
5
3
4
1
6
2
5
3
4
■ Electrical Characteristics (Ta = 25°C)
Output
Input
Item
Symbol Minimum Typical Maximum
LED forward voltage
VF
1.0
1.15
1.3
Reverse current
IR
10
Capacity between terminals
CT
30
Trigger LED forward current
IFT
1
3
Connection A
17
35
Maximum
Connection B
RON
11
20
resistance
with output ON Connection C
6
Current leakage when the relay is open
ILEAK
1.0
Capacity between terminals COFF
70
Capacity between I/O terminals
CI-O
0.8
Insulation resistance between I/O terminals
RI-O
1000
Turn-ON time
tON
0.3
1.0
Turn-OFF time
tOFF
0.1
1.0
1
Unit
V
µA
pF
mA
Ω
Ω
Ω
µA
pF
pF
MΩ
ms
ms
Measurement conditions
IF = 10 mA
VR = 5 V
Note: 2. Turn-ON and Turn-OFF Times
V = 0, f = 1 MHz
IF 1
6 RL
IO =120 mA
VDD
VOUT
IF = 5 mA, IO = 120 mA
2
4
IF = 5 mA, IO = 120 mA
IF = 5 mA, IO = 240 mA
VOFF = 400 V
V = 0, f = 1 MHz
IF
f = 1 MHz, Vs = 0 V
VI-O = 500 VDC, ROH ≤ 60 %
90%
VOUT
10%
IF = 5 mA, RL = 200 Ω,
t ON
t OFF
VDD = 20 V (See note 2.)
Load
or AC
DC
Load
DC
Load
DC
G3VM-401H
MOS FET Relays
■ Recommended Operating Conditions
Use the G3VM under the following conditions so that the Relay will operate properly.
Item
Symbol
Minimum
Typical
Maximum
Load voltage (AC peak/DC)
VDD
-
-
320
Unit
V
Operating LED forward current
IF
5
7.5
25
mA
Continuous load current (AC peak/DC)
IO
-
-
120
mA
Ambient operating temperature
Ta
−20
-
65
°C
■ Engineering Data
LED forward current vs. Ambient
temperature
Continuous load current vs. Ambient
temperature
100
80
60
40
IF - VF
LED forward current IF (mA)
IO - Ta
Continuous load current IO (mA)
LED forward current IF (mA)
IF - Ta
LED forward current vs. LED forward
voltage
280
Connection C
240
200
160
Connection A and B
120
50
30
10
5
3
1
0.5
0.3
40
0
0
-20
0
20
40
60
80
100
0.1
-20
120
0
20
40
Ambient temperature Ta (°C)
Continuous load current vs. On-state
voltage
60
80
100
120
0.6
On-state resistance vs. Ambient
temperature
100
0
IO = 120 mA
IF = 5 mA
50
40
30
20
0
1
2
-20
3
0
20
Turn ON, Turn OFF time vs. LED
forward current
tON, tOFF - IF
80
IO = 120 mA
t < 1s
4
3
2
1
0
100
-40
-20
0
20
Turn ON, Turn OFF time tON, tOFF (µs)
500
300
100
tOFF
50
40
60
80
100
Ambient temperature Ta (°C)
Current leakage vs. Ambient
temperature
tON, tOFF - Ta
Ta = 25°C
VDD = 20 V, RL = 200 Ω
tON
60
Turn ON, Turn OFF time vs. Ambient
temperature
2000
1000
40
1.8
5
Ambient temperature Ta (°C)
On-state voltage VON (V)
ILEAK - Ta
Current leakage ILEAK (nA)
0
1.6
IFT - Ta
60
10
-200
1.4
Trigger LED forward current vs.
Ambient temperature
-100
-1
1.2
LED forward voltage VF (V)
Trigger LED forward current IFT (mA)
On-state resistance RON (Ω)
Ta = 25 °C,
Connection A
IF = 5 mA
-2
1
RON - Ta
200
-3
0.8
Ambient temperature Ta (°C)
IO - VON
Continuous load current IO (mA)
Ta = 25°C
80
20
Turn ON, Turn OFF time tON, tOFF (µs)
100
1000
VDD = 20 V, RL = 200 Ω
IF = 5 mA
800
tON
600
400
1000
VOFF = 400 V
500
300
100
50
30
10
5
tOFF
200
3
30
1
3
5
10
30
50
100
LED forward current IF (mA)
1
0
-40
-20
0
20
40
60
80
100
Ambient temperature Ta (°C)
-20
0
20
40
60
80
100
Ambient temperature Ta (°C)
■ Safety Precautions
• Refer to "Common Precautions" for all G3VM models.
2
Appearance/Dimensions
SOP6 type
■ Appearance
SOP (Small Outline Package)
SOP6
OMRON logo
Model name
932
Pin 1 mark
LOT.No.
Note: The actual product is marked differently from the image shown here.
■ Dimensions
(Unit: mm)
Surface-mounting Terminals
Actual Mounting Pad
Dimensions
Weight: 0.13 g
4.4±0.25
(Recommended Value, TOP VIEW)
2.1 max.
6.3±0.25
6 to 6.3
1.2
0.15
0.8
2.54±0.25
0.1±0.1
0.4±0.1
Note: The actual product is marked differently from the image shown here.
0.6±0.3
7.0±0.4
2.54
2.54
• Application examples provided in this document are for reference only. In actual applications, confirm equipment functions and safety before using the product.
• Consult your OMRON representative before using the product under conditions which are not described in the manual or applying the product to nuclear control systems, railroad
systems, aviation systems, vehicles, combustion systems, medical equipment, amusement machines, safety equipment, and other systems or equipment that may have a serious
influence on lives and property if used improperly. Make sure that the ratings and performance characteristics of the product provide a margin of safety for the system or
equipment, and be sure to provide the system or equipment with double safety mechanisms.
Note: Do not use this document to operate the Unit.
OMRON Corporation
ELECTRONIC AND MECHANICAL COMPONENTS COMPANY
Contact: www.omron.com/ecb
Cat. No. K169-E1-01
0412(0412)(O)