G3VM-61HR(TR)

G3VM-61HR(TR)

  • 厂商:

    OMRON(欧姆龙)

  • 封装:

    SOP6

  • 描述:

    RELAY SSR SPST 60V 2.3A 6SOP

  • 数据手册
  • 价格&库存
G3VM-61HR(TR) 数据手册
G3VM-61HR MOS FET Relays Higher power, 2.3-A switching with a 60-V load voltage, SOP package. Low 40-mΩ ON Resistance. • Continuous load current of 2.3 A. (Connection C: 4.6 A) RoHS compliant Note: The actual product is marked differently from the image shown here. ■ Application Examples ■ Terminal Arrangement/Internal Connections 6 5 4 • Communication equipment • Test & Measurement equipment OMRON logo • Data loggers • Industrial equipment 1 Model name 61HR 932 Pin 1 mark LOT.No. 3 2 Note: The actual product is marked differently from the image shown here. ■ List of Models Package type Contact form Load voltage (peak value) * Terminals 1a Surface-mounting Terminals (SPST-NO) * The AC peak and DC value are given for the load voltage. SOP6 60 V Model G3VM-61HR G3VM-61HR (TR) Minimum package quantity Number per tube Number per tape and reel 75 2,500 ■ Absolute Maximum Ratings (Ta = 25°C) Output Input Item LED forward current LED forward current reduction rate LED reverse voltage Connection temperature Load voltage (AC peak/DC) Connection A Continuous Connection B load current Connection C Connection A ON current reduction Connection B rate Connection C Pulse ON current Connection temperature Dielectric strength between I/O (See note 1.) Ambient operating temperature Ambient storage temperature Soldering temperature Symbol IF ∆IF/°C VR TJ VOFF Unit mA mA/°C V °C V Iop TJ Rating 30 −0.3 5 125 60 2.3 2.3 4.6 −30.7 −30.7 −61.3 7 125 VI-O 1500 Vrms Ta Tstg - −40 to +85 −55 to +125 260 °C °C °C IO ∆IO/°C A mA/°C Measurement conditions Ta ≥ 25°C Note: 1. The dielectric strength between the input and output was checked by applying voltage between all pins as a group on the LED side and all pins as a group on the light-receiving side. Connection Diagram Connection A: AC peak/DC Connection B and C: DC Connection A Ta ≥ 50°C Connection B A °C t = 100 ms AC for 1 min With no icing or condensation With no icing or condensation 10 s Connection C 1 6 Load 2 5 3 4 or AC DC 1 6 2 5 3 4 1 6 2 5 3 4 ■ Electrical Characteristics (Ta = 25°C) Output Input Item Symbol Minimum Typical Maximum LED forward voltage VF 1.18 1.33 1.48 Reverse current IR 10 Capacity between terminals CT 70 Trigger LED forward current IFT 0.4 3 Connection A 0.04 0.07 Maximum resistance Connection B RON 0.02 0.04 with output ON Connection C 0.01 Current leakage when the relay is open ILEAK 10 Capacity between terminals Coff 1000 Capacity between I/O terminals CI-O 0.8 Insulation resistance between I/O terminals RI-O 1000 Turn-ON time tON 1.0 5.0 Turn-OFF time tOFF 0.15 1.0 1 Unit V µA pF mA Ω Ω Ω nA pF pF MΩ ms ms Measurement conditions IF = 10 mA VR = 5 V V = 0, f = 1 MHz Note: 2. Turn-ON and Turn-OFF Times IO = 100 mA IF 1 6 RL VDD IF = 5 mA, IO = 2 A, t < 1 s VOUT 2 4 IF = 5 mA, IO = 2 A, t < 1 s IF = 5 mA, IO = 4 A, t < 1 s VOFF = 60 V V = 0, f = 1 MHz IF f = 1 MHz, VS = 0 V VI-O = 500 VDC, ROH ≤ 60 % 90% VOUT 10% IF = 5 mA, RL = 200 Ω, t ON t OFF VDD = 20 V (See note 2.) Load DC Load DC G3VM-61HR MOS FET Relays ■ Recommended Operating Conditions Use the G3VM under the following conditions so that the Relay will operate properly. Item Symbol Minimum Typical Maximum Load voltage (AC peak/DC) VDD - - 60 Unit V Operating LED forward current IF 5 7.5 20 mA Continuous load current (AC peak/DC) IO - - 1.8 A Ambient operating temperature Ta −20 - 65 °C ■ Engineering Data Continuous load current vs. Ambient temperature Continuous load current IO (A) 50 40 30 20 IO - Ta 5 Connection C 4 3 2 Connection A and B Ta = 25°C 10 1 -20 0 20 40 60 80 0 -40 100 0.1 -20 0 20 Ambient temperature Ta (°C) Continuous load current vs. On-state voltage 60 80 100 Ta = 25°C 1 0 -1 0.05 Io = 2.0 A IF = 5 mA, 80 t < 1s, Connection A 60 40 0 -40 0.1 -20 0 On-state voltage VON (V) Turn ON, Turn OFF time vs. LED forward current VDD = 20 V, RL = 200 Ω, tON Ta = 25°C 1 0.1 tOFF 0.01 1 0.1 10 100 LED forward current IF (mA) 1.6 1.8 20 40 60 80 IO = 100 mA t < 1s 1.5 1.0 0.5 0.0 -40 100 -20 0 Ambient temperature Ta (°C) Turn ON, Turn OFF time vs. Ambient temperature Turn ON, Turn OFF time tON, tOFF (ms) tON, tOFF - IF 1.4 2.0 40 60 80 100 Current leakage vs. Load voltage ILEAK - VOFF 10 VDD = 20 V, RL = 200 Ω, 20 Ambient temperature Ta (°C) tON, tOFF - Ta 10 1.2 LED forward voltage VF (V) IFT - Ta 100 20 -2 0 1.0 On-state resistance vs. Ambient temperature Trigger LED forward current vs. Ambient temperature On-state resistance RON (mΩ) IF = 5 mA, Connection A -0.05 0.8 RON - Ta 3 -3 -0.1 0.6 Ambient temperature Ta (°C) IO - VON 2 40 Trigger LED forward current IFT (mA) 0 -40 Continuous load current IO (A) IF - VF 100 1 10 Turn ON, Turn OFF time tON, tOFF (ms) LED forward current vs. LED forward voltage Current leakage ILEAK (nA) LED forward current IF (mA) IF - Ta LED forward current IF (mA) LED forward current vs. Ambient temperature tON IF = 5 mA 1 tOFF 2.0 Ta = 25°C 1.5 1.0 0.1 0.5 0.01 -40 -20 0 20 40 60 80 100 Ambient temperature Ta (°C) 0.0 0 10 20 30 40 50 60 Load voltage (V) Output terminal capacitance vs. Load voltage Output terminal capacitance COFF/COFF (0V) COFF - VOFF 1.2 Ta = 25°C 1 0.8 0.6 0.4 0.2 0 0 10 20 30 40 Load voltage (V) ■ Safety Precautions • Refer to "Common Precautions" for all G3VM models. 2 Appearance/Dimensions SOP6 type ■ Appearance SOP (Small Outline Package) SOP6 OMRON logo Model name 932 Pin 1 mark LOT.No. Note: The actual product is marked differently from the image shown here. ■ Dimensions (Unit: mm) Surface-mounting Terminals Actual Mounting Pad Dimensions Weight: 0.13 g 4.4±0.25 (Recommended Value, TOP VIEW) 2.1 max. 6.3±0.25 6 to 6.3 1.2 0.15 0.8 2.54±0.25 0.1±0.1 0.4±0.1 Note: The actual product is marked differently from the image shown here. 0.6±0.3 7.0±0.4 2.54 2.54 • Application examples provided in this document are for reference only. In actual applications, confirm equipment functions and safety before using the product. • Consult your OMRON representative before using the product under conditions which are not described in the manual or applying the product to nuclear control systems, railroad systems, aviation systems, vehicles, combustion systems, medical equipment, amusement machines, safety equipment, and other systems or equipment that may have a serious influence on lives and property if used improperly. Make sure that the ratings and performance characteristics of the product provide a margin of safety for the system or equipment, and be sure to provide the system or equipment with double safety mechanisms. Note: Do not use this document to operate the Unit. OMRON Corporation ELECTRONIC AND MECHANICAL COMPONENTS COMPANY Contact: www.omron.com/ecb Cat. No. K176-E1-01 0412(0412)(O)
G3VM-61HR(TR) 价格&库存

很抱歉,暂时无法提供与“G3VM-61HR(TR)”相匹配的价格&库存,您可以联系我们找货

免费人工找货