MOS FET Relays
New Relay Incorporating a MOS FET Optically Coupled with an Infrared LED Has a 4-pin SOP Package and 80-V Load Voltage
• Continuous load current of 350 mA. • Dielectric strength of 1,500 Vrms between I/O.
G3VM-81G1
■ Application Examples
• Broadband systems • Measurement devices • Data loggers • Amusement machines Note: The actual product is marked differently from the image shown here.
■ List of Models
Contact form SPST-NO Terminals Surface-mounting terminals Load voltage (peak value) 80 VAC Model G3VM-81G1 G3VM-81G1(TR) Number per stick 100 --Number per tape --2,500
■ Dimensions
Note: All units are in millimeters unless otherwise indicated. G3VM-81G1
4.4±0.25
3.9±0.2
2.1 max. 0.15
Note: The actual product is marked differently from the image shown here.
0.4±0.1 2.54±0.25
0.1±0.1
0.6±0.3 7.0±0.4
Weight: 0.1 g
■ Terminal Arrangement/Internal Connections (Top View)
G3VM-81G1
4 3
1
2
■ Actual Mounting Pad Dimensions (Recommended Value, Top View)
G3VM-81G1
6 to 6.3 1.2
0.8 2.54
62
G3VM-81G1 ■ Absolute Maximum Ratings (Ta = 25°C)
Item Input LED forward current Repetitive peak LED forward current LED forward current reduction rate LED reverse voltage Connection temperature Output Output dielectric strength Continuous load current ON current reduction rate Connection temperature Dielectric strength between input and output (See note 1.) Operating temperature Storage temperature Soldering temperature (10 s) Symbol IF IFP D IF/°C VR Tj VOFF IO D ION/°C Tj VI-O Ta Tstg --Rating 50 1 -0.5 5 125 80 350 -3.5 125 1,500 -40 to +85 Unit mA A mA/°C V °C V mA mA/°C °C Vrms °C °C AC for 1 min With no icing or condensation With no icing or condensation 10 s Ta ³ 25°C 100 ms pulses, 100 pps Ta ³ 25°C Measurement Conditions
G3VM-81G1
Note:
1. The dielectric strength between the input and output was checked by applying voltage between all pins as a group on the LED side and all pins as a group on the light-receiving side.
-55 to +125 °C 260
■ Electrical Characteristics (Ta = 25°C)
Item Input LED forward voltage Reverse current Capacity between terminals Trigger LED forward current Output Maximum resistance with output ON Current leakage when the relay is open Capacity between I/O terminals Insulation resistance Turn-ON time Turn-OFF time Symbol VF IR CT IFT RON ILEAK CI-O RI-O tON tOFF Minimum 1.0 ------------1,000 ----Typical 1.15 --15 1.0 1.0 0.2 0.8 --0.3 0.3 Maximum 1.3 10 --4.0 1.2 1.0 ----0.5 0.5 V mA pF mA W nA pF MW ms ms Unit Measurement conditions IF = 10 mA VR = 5 V V = 0, f = 1 MHz IO = 350 mA IF = 5 mA, IO = 350 mA VOFF = 30 V, Ta = 50°C f = 1 MHz, Vs = 0 V VI-O = 500 VDC, RoH £ 60% IF = 5 mA, RL = 200 W, VDD = 20 V (See note 2.)
VOUT IF
Note:
2. Turn-ON and Turn-OFF Times
IF 1 2 4 3 RL VDD VOUT
10% t ON
90% t OFF
■ Recommended Operating Conditions
Use the G3VM under the following conditions so that the Relay will operate properly.
Item Output dielectric strength Operating LED forward current Continuous load current Operating temperature Symbol VDD IF IO Ta --5 --25 Minimum --------Typical 64 30 350 60 Maximum V mA mA °C Unit
■ Engineering Data
Load Current vs. Ambient Temperature
G3VM-81G1
Load current (mA) 500
■ Safety Precautions
Refer to page 6 for precautions common to all G3VM models.
400
300
200
100
0 −20
0
20
40 60 80 100 Ambient temperature (°C)