G3VM-WL/WFL
MOS FET Relays
Current-limiting Models with 350-V Load
Voltage. Including Models with 2
Outputs.
• Current limit 150 to 300 mA.
RoHS compliant
Note: Note: The actual product is marked differently from
the image shown here.
■ Application Examples
■ Terminal Arrangement/Internal
Connections
• Communication equipment
8
• Test & Measurement equipment
7
6
5
OMRON logo
1
2
3
Model
name
LOT.NO.
932
Pin 1 mark
4
Note: The actual product is marked differently from the image shown here.
■ List of Models
Package type Contact form
Load voltage
(peak value) *
Terminals
Model
PCB Terminals
2a
(DPST-NO)
DIP8
Minimum package quantity
Current limit
Number per tube Number per tape and reel
G3VM-WL
350 V
Surface-mounting
Terminals
G3VM-WFL
Available
G3VM-WFL (TR)
50
-
-
1,500
* The AC peak and DC value are given for the load voltage.
Output
Input
■ Absolute Maximum Ratings (Ta = 25°C)
Item
Symbol
Rating
Unit
LED forward current
IF
50
mA
Repetitive peak LED forward current
IFP
1
A
LED forward current reduction rate
∆IF/°C
−0.5
mA/°C
VR
6
V
Connection temperature
TJ
125
°C
Load voltage (AC peak/DC)
VOFF
350
V
Continuous load current (AC peak/DC)
IO
120
mA
ON current reduction rate
∆IO/°C
−1.2
mA/°C
Connection temperature
TJ
125
°C
VI-O
2500
Vrms
LED reverse voltage
Dielectric strength between
I /O (See note 1.)
Measurement conditions
100 µs pulses, 100 pps
Ta ≥ 25°C
Ta ≥ 25°C
AC for 1 min
Ta
−40 to +85
°C
With no icing or condensation
Ambient storage temperature
Tstg
−55 to +125
°C
With no icing or condensation
Soldering temperature
-
260
°C
10 s
Ambient operating temperature
Note: 1. The dielectric strength between the input and
output was checked by applying voltage
between all pins as a group on the LED side and
all pins as a group on the light-receiving side.
■ Electrical Characteristics (Ta = 25°C)
Item
Symbol Minimum Typical Maximum
1.0
Reverse current
IR
Capacity between terminals
CT
Trigger LED forward current
Maximum resistance with output ON
Measurement conditions
1.3
V
IF = 10 mA
-
-
10
µA
VR = 6 V
-
30
-
pF
V = 0, f = 1 MHz
IFT
-
1
3
mA
IO = 120 mA
RON
-
22
35
Ω
IF = 5 mA, IO = 120 mA
Current leakage when the relay is open
ILEAK
-
-
1.0
µA
VOFF = 350 V
Capacity between terminals
COFF
-
40
-
pF
V = 0, f = 1 MHz
Limit current
ILIM
150
-
300
mA
IF = 5 mA, VDD = 5 V, t = 5 ms
Capacity between I/O terminals
CI-O
-
0.8
-
pF
f = 1 MHz, VS = 0 V
Insulation resistance between I/O terminals
RI-O
1000
-
-
MΩ
VI-O = 500 VDC, ROH ≤ 60%
Turn-ON time
tON
-
-
1.0
ms
IF = 5 mA, RL = 200 Ω,
VDD = 20 V(See note 2.)
Output
VF
Unit
1.15
Input
LED forward voltage
Turn-OFF time
1
tOFF
-
-
1.0
ms
Note: 2. Turn-ON and Turn-OFF Times
IF 1
8
2
7
RL
VDD
VOUT
IF
VOUT
10%
t ON
90%
t OFF
G3VM-WL/WFL
MOS FET Relays
■ Recommended Operating Conditions
Use the G3VM under the following conditions so that the Relay will operate properly.
Item
Symbol
Minimum
Typical
Maximum
VDD
-
-
280
V
Operating LED forward current
IF
5
7.5
25
mA
Continuous load current (AC peak/DC)
IO
-
-
100
mA
Ambient operating
temperature
Ta
−20
-
65
°C
Load voltage (AC peak/DC)
Unit
■ Engineering Data
LED forward current vs. Ambient
temperature
Continuous load current vs. Ambient
temperature
IO - Ta
40
20
IF - VF
150
LED forward current IF (mA)
60
Continuous load current IO (mA)
LED forward current IF (mA)
IF - Ta
LED forward current vs. LED forward
voltage
120
90
60
100
Ta = 25°C
10
1
30
0.1
0
0
-20
0
20
40
60
80
-40
100
0
-20
Ambient temperature Ta (°C)
Continuous load current vs. On-state
voltage
60
80
0.6
100
On-state resistance vs. Ambient
temperature
Ta = 25°C
IF = 5mA
90
60
30
0
-30
1
1.2
1.6
1.8
IFT - Ta
25
IO = 120mA
IF = 5mA
t < 1s
20
1.4
LED forward voltage VF (V)
Trigger LED forward current vs.
Ambient temperature
15
10
-60
-90
5
1.5
IO = 120mA
t < 1s
1.4
1.3
1.2
1.1
1.0
0.9
0.8
0.7
0.6
-120
-150
0.5
0
-1.5 -1.0
-0.5
0
0.5
1.0
1.5
2.0
-40
0
-20
On−state voltage VON (V)
Turn ON, Turn OFF time vs. LED
forward current
20
40
60
80
Turn ON, Turn OFF time vs. Ambient
temperature
tON, tOFF - IF
0
-20
Turn ON, Turn OFF time tON, tOFF (µs)
Ta = 25°C
VDD = 20V
RL = 200Ω
tOFF
100
tON
400
10
100
40
60
80
100
Current leakage vs. Ambient
temperature
ILEAK - Ta
VDD = 20V
RL = 200Ω
IF = 5mA
300
tON
100
VOFF = 350V
10
1
200
tOFF
0.1
100
10
20
Ambient temperature Ta (°C)
tON, tOFF - Ta
1000
1
-40
100
Ambient temperature Ta (°C)
Current leakage ILEAK (nA)
-2.0
Turn ON, Turn OFF time tON, tOFF (µs)
0.8
RON - Ta
On-state resistance RON (Ω)
Continuous load current IO (mA)
40
Ambient temperature Ta (°C)
IO - VON
150
120
20
Trigger LED forward current IFT (mA)
-40
-40
-20
0
LED forward current IF (mA)
20
40
60
80
100
Ambient temperature Ta (°C)
20
40
60
80
100
Ambient temperature Ta (°C)
■ Safety Precautions
• Refer to "Common Precautions" for all G3VM models.
2
Appearance/Dimensions
DIP8 type
■ Appearance
DIP (Dual Inline Package)
DIP8
OMRON logo
Model name
932
Pin 1 mark
LOT.NO.
Note: The actual product is marked differently from the image shown here.
■ Dimensions
(Unit:mm)
PCB Terminals
Surface-mounting Terminals PCB Dimensions (BOTTOM VIEW)
Weight: 0.54 g
Weight: 0.54 g
Eight, 0.8-dia. holes
2.54
(0.61)
2.54
9.66±0.25
9.66±0.25
6.4±0.25
7.62±0.25
Actual Mounting Pad Dimensions
0.8±0.25
7.62±0.25
(Recommended Value, TOP VIEW)
3.65+0.15
–0.25
0.25+0.1
–0.05
2.5 min.
1.2±0.15
0.5±0.1
2.54±0.25
(0.61)
(1.52)
(1.52)
6.4±0.25
7.85 to 8.80
3.65+0.15
−0.25
4.0+0.25
−0.2
1.2±0.15
2.54±0.25
Note: The actual product is marked differently from the
image shown here.
2.54
1.0 min.
1.0 min.
10.0 max.
8.3 to 8.8
1.3
1.5
• Application examples provided in this document are for reference only. In actual applications, confirm equipment functions and safety before using the product.
• Consult your OMRON representative before using the product under conditions which are not described in the manual or applying the product to nuclear control systems, railroad
systems, aviation systems, vehicles, combustion systems, medical equipment, amusement machines, safety equipment, and other systems or equipment that may have a serious
influence on lives and property if used improperly. Make sure that the ratings and performance characteristics of the product provide a margin of safety for the system or
equipment, and be sure to provide the system or equipment with double safety mechanisms.
Note: Do not use this document to operate the Unit.
OMRON Corporation
ELECTRONIC AND MECHANICAL COMPONENTS COMPANY
Contact: www.omron.com/ecb
Cat. No. K234-E1-01
0412(0412)(O)
很抱歉,暂时无法提供与“G3VM-WFL”相匹配的价格&库存,您可以联系我们找货
免费人工找货- 国内价格 香港价格
- 1+47.777721+6.18115
- 10+42.5836610+5.50917
- 25+40.6721225+5.26187
- 50+39.2770050+5.08138