G3VM-WFL

G3VM-WFL

  • 厂商:

    OMRON(欧姆龙)

  • 封装:

    SMD8

  • 描述:

    RELAY SSR DPST-NO 350V 8SMD

  • 数据手册
  • 价格&库存
G3VM-WFL 数据手册
G3VM-WL/WFL MOS FET Relays Current-limiting Models with 350-V Load Voltage. Including Models with 2 Outputs. • Current limit 150 to 300 mA. RoHS compliant Note: Note: The actual product is marked differently from the image shown here. ■ Application Examples ■ Terminal Arrangement/Internal Connections • Communication equipment 8 • Test & Measurement equipment 7 6 5 OMRON logo 1 2 3 Model name LOT.NO. 932 Pin 1 mark 4 Note: The actual product is marked differently from the image shown here. ■ List of Models Package type Contact form Load voltage (peak value) * Terminals Model PCB Terminals 2a (DPST-NO) DIP8 Minimum package quantity Current limit Number per tube Number per tape and reel G3VM-WL 350 V Surface-mounting Terminals G3VM-WFL Available G3VM-WFL (TR) 50 - - 1,500 * The AC peak and DC value are given for the load voltage. Output Input ■ Absolute Maximum Ratings (Ta = 25°C) Item Symbol Rating Unit LED forward current IF 50 mA Repetitive peak LED forward current IFP 1 A LED forward current reduction rate ∆IF/°C −0.5 mA/°C VR 6 V Connection temperature TJ 125 °C Load voltage (AC peak/DC) VOFF 350 V Continuous load current (AC peak/DC) IO 120 mA ON current reduction rate ∆IO/°C −1.2 mA/°C Connection temperature TJ 125 °C VI-O 2500 Vrms LED reverse voltage Dielectric strength between I /O (See note 1.) Measurement conditions 100 µs pulses, 100 pps Ta ≥ 25°C Ta ≥ 25°C AC for 1 min Ta −40 to +85 °C With no icing or condensation Ambient storage temperature Tstg −55 to +125 °C With no icing or condensation Soldering temperature - 260 °C 10 s Ambient operating temperature Note: 1. The dielectric strength between the input and output was checked by applying voltage between all pins as a group on the LED side and all pins as a group on the light-receiving side. ■ Electrical Characteristics (Ta = 25°C) Item Symbol Minimum Typical Maximum 1.0 Reverse current IR Capacity between terminals CT Trigger LED forward current Maximum resistance with output ON Measurement conditions 1.3 V IF = 10 mA - - 10 µA VR = 6 V - 30 - pF V = 0, f = 1 MHz IFT - 1 3 mA IO = 120 mA RON - 22 35 Ω IF = 5 mA, IO = 120 mA Current leakage when the relay is open ILEAK - - 1.0 µA VOFF = 350 V Capacity between terminals COFF - 40 - pF V = 0, f = 1 MHz Limit current ILIM 150 - 300 mA IF = 5 mA, VDD = 5 V, t = 5 ms Capacity between I/O terminals CI-O - 0.8 - pF f = 1 MHz, VS = 0 V Insulation resistance between I/O terminals RI-O 1000 - - MΩ VI-O = 500 VDC, ROH ≤ 60% Turn-ON time tON - - 1.0 ms IF = 5 mA, RL = 200 Ω, VDD = 20 V(See note 2.) Output VF Unit 1.15 Input LED forward voltage Turn-OFF time 1 tOFF - - 1.0 ms Note: 2. Turn-ON and Turn-OFF Times IF 1 8 2 7 RL VDD VOUT IF VOUT 10% t ON 90% t OFF G3VM-WL/WFL MOS FET Relays ■ Recommended Operating Conditions Use the G3VM under the following conditions so that the Relay will operate properly. Item Symbol Minimum Typical Maximum VDD - - 280 V Operating LED forward current IF 5 7.5 25 mA Continuous load current (AC peak/DC) IO - - 100 mA Ambient operating temperature Ta −20 - 65 °C Load voltage (AC peak/DC) Unit ■ Engineering Data LED forward current vs. Ambient temperature Continuous load current vs. Ambient temperature IO - Ta 40 20 IF - VF 150 LED forward current IF (mA) 60 Continuous load current IO (mA) LED forward current IF (mA) IF - Ta LED forward current vs. LED forward voltage 120 90 60 100 Ta = 25°C 10 1 30 0.1 0 0 -20 0 20 40 60 80 -40 100 0 -20 Ambient temperature Ta (°C) Continuous load current vs. On-state voltage 60 80 0.6 100 On-state resistance vs. Ambient temperature Ta = 25°C IF = 5mA 90 60 30 0 -30 1 1.2 1.6 1.8 IFT - Ta 25 IO = 120mA IF = 5mA t < 1s 20 1.4 LED forward voltage VF (V) Trigger LED forward current vs. Ambient temperature 15 10 -60 -90 5 1.5 IO = 120mA t < 1s 1.4 1.3 1.2 1.1 1.0 0.9 0.8 0.7 0.6 -120 -150 0.5 0 -1.5 -1.0 -0.5 0 0.5 1.0 1.5 2.0 -40 0 -20 On−state voltage VON (V) Turn ON, Turn OFF time vs. LED forward current 20 40 60 80 Turn ON, Turn OFF time vs. Ambient temperature tON, tOFF - IF 0 -20 Turn ON, Turn OFF time tON, tOFF (µs) Ta = 25°C VDD = 20V RL = 200Ω tOFF 100 tON 400 10 100 40 60 80 100 Current leakage vs. Ambient temperature ILEAK - Ta VDD = 20V RL = 200Ω IF = 5mA 300 tON 100 VOFF = 350V 10 1 200 tOFF 0.1 100 10 20 Ambient temperature Ta (°C) tON, tOFF - Ta 1000 1 -40 100 Ambient temperature Ta (°C) Current leakage ILEAK (nA) -2.0 Turn ON, Turn OFF time tON, tOFF (µs) 0.8 RON - Ta On-state resistance RON (Ω) Continuous load current IO (mA) 40 Ambient temperature Ta (°C) IO - VON 150 120 20 Trigger LED forward current IFT (mA) -40 -40 -20 0 LED forward current IF (mA) 20 40 60 80 100 Ambient temperature Ta (°C) 20 40 60 80 100 Ambient temperature Ta (°C) ■ Safety Precautions • Refer to "Common Precautions" for all G3VM models. 2 Appearance/Dimensions DIP8 type ■ Appearance DIP (Dual Inline Package) DIP8 OMRON logo Model name 932 Pin 1 mark LOT.NO. Note: The actual product is marked differently from the image shown here. ■ Dimensions (Unit:mm) PCB Terminals Surface-mounting Terminals PCB Dimensions (BOTTOM VIEW) Weight: 0.54 g Weight: 0.54 g Eight, 0.8-dia. holes 2.54 (0.61) 2.54 9.66±0.25 9.66±0.25 6.4±0.25 7.62±0.25 Actual Mounting Pad Dimensions 0.8±0.25 7.62±0.25 (Recommended Value, TOP VIEW) 3.65+0.15 –0.25 0.25+0.1 –0.05 2.5 min. 1.2±0.15 0.5±0.1 2.54±0.25 (0.61) (1.52) (1.52) 6.4±0.25 7.85 to 8.80 3.65+0.15 −0.25 4.0+0.25 −0.2 1.2±0.15 2.54±0.25 Note: The actual product is marked differently from the image shown here. 2.54 1.0 min. 1.0 min. 10.0 max. 8.3 to 8.8 1.3 1.5 • Application examples provided in this document are for reference only. In actual applications, confirm equipment functions and safety before using the product. • Consult your OMRON representative before using the product under conditions which are not described in the manual or applying the product to nuclear control systems, railroad systems, aviation systems, vehicles, combustion systems, medical equipment, amusement machines, safety equipment, and other systems or equipment that may have a serious influence on lives and property if used improperly. Make sure that the ratings and performance characteristics of the product provide a margin of safety for the system or equipment, and be sure to provide the system or equipment with double safety mechanisms. Note: Do not use this document to operate the Unit. OMRON Corporation ELECTRONIC AND MECHANICAL COMPONENTS COMPANY Contact: www.omron.com/ecb Cat. No. K234-E1-01 0412(0412)(O)
G3VM-WFL 价格&库存

很抱歉,暂时无法提供与“G3VM-WFL”相匹配的价格&库存,您可以联系我们找货

免费人工找货
G3VM-WFL
  •  国内价格 香港价格
  • 1+47.777721+6.18115
  • 10+42.5836610+5.50917
  • 25+40.6721225+5.26187
  • 50+39.2770050+5.08138

库存:55