9
PCB Relay
G5S
Compact Single-pole Relay for
Switching Up To 5 A (Normally Open
Contact), Ideal for Fan Control of Air
Conditioners, and Heating Control of
Small Appliances
1 Compact relay with high insulation
between coil and contacts
1 Up to 5A switching on the NO contacts
1 Ensures a withstand impulse voltage of
8,000 V between the coil and contacts
1 Class B coil insulation available
1 Conforms to UL, CSA, and IEC (TÜV)
Ordering Information
Classification
Single
g contact
Enclosure rating
Part number
SPDT
Plastic-sealed
G5S-1 (-CB for Class B)
SPST-NO
Plastic-sealed
G5S-1A (-CB for class B)
Note: When ordering, add the rated coil voltage to the model number.
Example: G5S-1 DC12
Rated coil voltage
3 MODEL NUMBER LEGEND
G5S-PP-P-P-DCP
12 3 4
1. Contact Pole
1: Single pole
5
2. Contact Form
nil = 1 form C
A = 1 form A
3. Insulation class
nil = standard
CB = Class B
4. Enclosure
nil = plastic sealed
v = vented
5. Rated Coil Voltage
5, 9, 12, 18, 24, 48 VDC
G5S
G5S
Specifications
3 COIL RATINGS
Rated voltage
5 VDC
9 VDC
12 VDC
18 VDC
24 VDC
48 VDC
Rated current
80 mA
44.4 mA
33.3 mA
22.2 mA
16.7 mA
8.3 mA
Coil resistance
62.5 Ω
202.5 Ω
360 Ω
810 Ω
1,440 Ω
5,760 Ω
Must operate voltage
75% max. of rated voltage
Must release voltage
5% min. of rated voltage
Max. voltage
150% of rated voltage at 23°C, 110% of rated voltage at 70°C
Power consumption
Approx. 400 mW
Note: Rated current and coil resistance are measured at 23°C with a tolerance of ±10%.
3 CONTACT RATINGS
Load
Resistive load
Inductive load
Rated load
2 A (NO)/2 A (NC) at 277 VAC
5 A (NO)/3 A (NC) at 125 VAC
5 A (NO)/3 A (NC) at 30 VDC
0.5 A at 250 VAC, cosφ=0.4
1 A at 250 VAC, cosφ=0.8
0.8 A at 250 VAC, cosφ=0.9
Contact material
Ag
Rated carry current
5 A (NO)/3 A (NC)
Max. switching voltage
277 VAC, 30 VDC
Max. switching current
5 A (NO)/3 A (NC)
1A
Max. switching capacity
625 VA, 150 W (NO)
375 VA, 90 W (NC)
250 VA
Min. permissible load
10 mA at 5 VDC
Note: P level: λ60=0.1 x 10--6 operation (with an operating frequency of 120 operations/min.)
3 CHARACTERISTICS
Contact resistance (See Note 2.)
100 mΩ max.
Operate time (See Note 3.)
10 ms max.
Release time (See Note 3.)
5 ms max.
Insulation resistance (See Note 4.)
1,000 MΩ min.
Dielectric strength
4,000 VAC, 50/60 Hz for 1 min between coil and contacts
750 VAC, 50/60 Hz for 1 min between contacts of same polarity
Impulse withstand voltage
8 kV (1.2 x 50 µs)
Vibration resistance
Destruction: 10 to 55 Hz, 1.5
1.5-mm
mm double am
amplitude
litude for 2 hours
Malfunction: 10 to 55 Hz, 1.5-mm double amplitude for 5 minutes
Shock resistance
Destruction: 1,000 m/s2 (approx. 100G)
Malfunction: Energized: 100 m/s2 (approximately 10G)
Non-energized: 50 m/s2 (approximately 5G)
(This table continues on the next page.)
2
G5S
G5S
Characteristics Table -- continued from previous page
Mechanical
5,000,000 operations (18,000 operations per hour)
Electrical
200,000 operations: 1 A (NO)/1 A (NC) at 277-VAC resistive load
3 A (NO)/3 A (NC) at 125-VAC resistive load
100,000 operations: 0.8 A (NO)/0.8 A (NC) at 250 VAC, cosφ=0.9
5 A (NO)/3 A (NC) at 30-VDC resistive load
50,000 operations: 2 A (NO)/2 A (NC) at 277-VAC resistive load
5 A (NO)/3 A (NC) at 125-VAC resistive load
Switching
frequency
1,800 operations per hour
Ambient temperature
Operating &
storage
--40°C to 70°C (--40°F to 158°F) with no icing or condensation
--40°C to 85°C (class B) (--40°F to 185°F)
Ambient humidity
Operating &
storage
35% to 85%
Life expectancyy (See
Note 5.))
(
Weight
Note: 1.
2.
3.
4.
5.
Approx. 8.0 g
The data shown above are initial values.
The contact resistance is possible with 1 A applied at 5 VDC using a fall-of-potential method.
The operating time is possible with the rated voltage imposed with no contact bounce at an ambient temperature of 23°C.
The insulation resistance is possible between coil and contacts and between contacts of the same polarity at 500 VDC.
The electrical life data items shown are possible at 23°C.
3 APPROVED STANDARDS
UL508 (File No. E41515)
CSA C22.2 (No. 14) (File No. LR31928)
Model
Coil ratings
Contact ratings
Number of test operations
G5S-1 (-CB)
G5S-1A (-CB)
5--48 VDC
0.8 A, 277 VAC (resistive)
0.5 A, 250 VAC (resistive)
2 A, 120 VAC (resistive)
2 A, 30 VDC (resistive)
5 A, 125 VAC (resistive)
1/10 HP, 125 VAC
5 A, 277 VAC (resistive)
1/6 HP, 277 VAC
0.3 A, 110 VDC (resistive)
5 A, 30 VDC (resistive)
6,000
TÜV (IEC 255, VDE0435 File No. R9650783)
Electrical life tests are performed at 70°C.
Model
Coil ratings
Contact ratings
Number of test operations
G5S-1 (-CB)
G5S-1A (-CB)
5,6,9,12,18,20,24,48
1.5 A, 277 VAC (resistive)
1 A, 250 VAC (resistive)
2 A, 30 VDC (resistive)
30,000
100,000
30,000
1 A, 250 VAC, cosφ=0.8
0.5 A, 250 VAC, cosφ=0.4
1 A, 250 VAC, cosφ=0.8 (NO only)
1 A, 250 VAC, cosφ=0.8 (NC only)
100,000
30,000
200,000
200,000
Note: Pollution Degree 2, Overvoltage Category II, Material Group III
3
G5S
G5S
Engineering Data
3 MAX. SWITCHING CAPACITY
10
10
125-VAC resistive
load (NO)
30-VDC resistive
load (NO)
5
30-VDC resistive
load (NC)
Switching current (A)
Switching current (A)
3
2
1
125-VAC resistive
load (NC)
277-VAC resistive
load (NO/NC)
250-VAC resistive
load (NO/NC)
250-VAC inductive
load (cosφ=0.8)
1
0.5
250-VAC inductive
load (cosφ=0.4)
0
10
0
100
277
0
1,000
10
0
100
277
1,000
Switching voltage (V)
Switching voltage (V)
3 AMBIENT TEMPERATURE VS.
MAXIMUM VOLTAGE
3 LIFE EXPECTANCY
200
10,000
180
Life expectancy (x10 operations)
140
120
110
125 VAC
(NO only)
1,000
3
Maximum voltage (%)
160
100
80
60
40
100
250 VAC
(cosφ=0.9)
10
277 VAC
20
0
--40
--20
0
23
40
60
Ambient temperature (°C)
4
70
80
1
0
1
2
3
4
Switching current (A)
5
6
G5S
G5S
Dimensions
Unit: mm (inch)
3 G5S
SPDT
Terminal Arrangement/
Internal Connections
(Bottom View)
PCB Mounting Holes
(Bottom View)
Tolerance: ±0.1 mm
(See
Note.)
(See
Note.)
Direction marker
(See
Note.)
Five, 1.3±0.1-dia. holes
(No coil polarity)
Note: Values in parentheses are average values.
3 SPST-NO
Terminal Arrangement/
Internal Connections
(Bottom View)
PCB Mounting Holes
(Bottom View)
Tolerance: ±0.1 mm
(See
Note.)
(See
Note.)
(1.08)
(See
Note.)
Direction marker
Four, 1.3±0.1-dia. holes
(No coil polarity)
Note: Values in parentheses are average values.
Precautions
For general precautions on PCB Relays, refer to the precautions provided in General Information of the Relay Product Data Book.
! Caution
Do not touch the terminals of the Relay or the charted part of
the socket when power is supplied to the Relay. Otherwise, an
electric shock may occur.
5
NOTE: DIMENSIONS SHOWN ARE IN MILLIMETERS. To convert millimeters to inches divide by 25.4.
9
OMRON ELECTRONICS, INC.
OMRON CANADA, INC.
One East Commerce Drive
Schaumburg, IL 60173
885 Milner Avenue
Scarborough, Ontario M1B 5V8
1-800-55-OMRON
416-286-6465
Cat. No. GC RLY7
01/00
Specifications subject to change without notice.
Printed in U.S.A.