P.1
Number: G6A-0903024B
Date of Issue: Nov.10.2011
For Reference
OMRON Corporation
OMRON Relay & Devices Corporation
Prepared by
Y.SUGA
Checked by
T.ASO
Authorized by
T.MATSUSHITA
Name: MINI RELAY
Model: G6A-2-H
Item: DC ALL
Registration part number for Customer
Type name:
Type number:
Receipt Stamp(For receipt purpose only)
Handled by
Please accept handling of this specification sheet as for
reference use if no reply received.
Distribution
Copy
Revision Record
Mark Date
Contents
Customer
Sales(
)
DP-720101-2C
Spec No:G6A-0903024B
P. 2
1.Classification
Single stable relay
2.Construction
2.1 Outline dimensions
Drawing No.2479484-3
2.2
Structure drawing
Drawing No.--------
2.3
Contact configuration
DPDT (2c contact)
2.4
Contact structure
Twin crossbar contact
2.5
Contact material
2.6
Protective construction
Face material
Base material
Plastic sealed
3.Standards
3.1 Approved by standard(s)
3.2
Others
4.Ratings
4.1 Coil ratings
(5)
(6)
UL
CSA
File No.
File No.
FCC
Part68
:E41515
:LR31928
See table1
4.2 Contact ratings
(1) Rated load
(2)
(3)
(4)
Au Alloy
Ag
Resistive load 125VAC 0.5A
30VDC 2A
Inductive load 125VAC 0.3A
(p.f.=0.4)
30VDC 1A
(L/R=7ms)
Rated carry current
3A
Maximum rated voltage 250 VAC 220VDC
Maximum rated current
Resistive load AC2A DC2A
Inductive load AC1A
(p.f.=0.4)
DC1A
(L/R=7ms)
Maximum switching capacity
Resistive load AC125VA DC60W
Inductive load AC62.5VA
(p.f.=0.4)
DC30W
(L/R=7ms)
Failure rate(reference value)
DC10mV 10μA
(P level)( λ =0.1×10 /ops.)
5.Characteristics(initial value)
5.1 Contact resistance
50 mΩ MAX.
Measured by the voltage drop method with
DC1V 10mA applied
5.2 Must operate voltage(or set voltage)
See table 1
5.3 Must release voltage(or reset voltage) See table 1
5.4 Operate time (or set time) 5 ms MAX.(at rated voltage)
5.5 Release time (or reset time)3 ms MAX.(at rated voltage)
5.6 Minimum input pulse width
--- ms
(Applicable to latching relay only, at rated voltage)
Spec No:G6A-0903024B
P. 3
5.7 Insulation resistance 500VDC
(1)Between coil terminals and contact terminals
1000 MΩ MIN.
(2)Between non-continuous current-carrying contact terminals
1000 MΩ MIN.
(3)Between contact terminals of the same polarity
1000 MΩ MIN.
(4)Between set coil and reset coil
---- MΩ MIN.
(5)Between current-carrying terminal and exposed non-current currying
metal part.
---- MΩ MIN.
5.8 Dielectric strength(leakage current1mA 50/60Hz for a minute)
(1)Between coil terminals and contact terminals
AC1000 V
(2)Between non-continuous current-carrying terminals
AC1000 V
(3)Between contact terminals of the same polarity
AC750 V
(4)Between set coil and reset coil
AC---- V
(5)Between current-carrying terminal and exposed non-current carrying
metal part.
AC---- V
5.9 Temperature rise
(1) Coil
(2) Contact
5.10 Vibration
(1) Mechanical durability
(2) Malfunction durability
(When energized)
or set status
65℃ MAX.
(by the coil resistance method)at.---℃
Applied voltage of coil:100%
of rated voltage---Hz
Carry current of contact3A
65℃ MAX.
(by the thermometer method)at.---℃
Applied voltage of coil:100%
of rated voltage ---Hz
Carry current of contact3A
Must be free from any abnormality in both
the construction and characteristics after the
relay is subjected to a variable vibration of
2.5mm single amplitude(5mm double amplitude)
at a vibration frequency of 10-55-10 Hz
in each direction for 2 hours.
Contacts must not open for 1ms
or longer after the relay is subjected to a
variable vibration of 1.65mm single amplitude
(3.3mm double amplitude) at a vibration frequency
of 10-55-10 Hz in each direction for 1 cycle.
(When not energized) Contacts must not open for 1ms
or reset status
or longer after the relay is subjected to a
variable vibration of 1.65mm single amplitude
(3.3mm double amplitude) at a vibration frequency
of 10-55-10 Hz in each direction for 1 cycle.
5.11 Shock
(1)Mechanical durability
Must be free from any abnormality in both
the construction and characteristics after the
relay is subjected to a shock of 1000m/s
in each direction 3 times.
Spec No:G6A-0903024B
P. 4
(2)Malfunction durability
(When energized)
or set status
(When not energized)
or reset status
Contacts must not open for1ms
or longer after the relay is subjected to a
shock of 500 m/s in each direction
3times.
Contacts must not open for1ms or
longer after the relay is subjected to a shock
of 500m/s in each direction
3times.
5.12 Terminal strength
Must be free from any abnormality after
a tensile stress of 4.9N is applied to the
terminal in any direction vertical to the
terminal tip for 10 seconds.
Any deformation of the terminal by the load
shall not be regard as a mechanical damage.
5.13 Temperature resistance
(1) Heat resistance
Must be free from any abnormality in both the
construction and characteristics after the
relay is left in a temperature of 85±2℃
for 16 hours and then in room temperature and
humidity for 2 hours.
(2) Cold resistance
Must be free from any abnormality in both the
construction and characteristics after the
relay is left in a temperature of -55±3 ℃
for 72 hours and then in room temperature and
humidity for 2 hours.
5.14 Moisture resistance
Must be free from any abnormality in both the
construction and characteristics after the
relay is left in a humidity of 90 to 95% RH
for 48 hours at a temperature of 40±2℃, and
then in room temperature and humidity for
2 hours.
Insulation resistance, however,
must be 5 MΩ MIN.
5.15 Soldering heat
The product shall be free from any abnormality
in both the construction and characteristics
after the terminals are dipped into molten
solder at 260±5℃ for 10 seconds and
then left in room temperature and humidity for
2 hours or after mounted by the recommended
condition of temperature profiles shown in
item ---.
5.16 Endurance
(1)Mechanical endurance
(2)Electrical endurance
100,000,000 operations MIN.
(under no load at operating frequency of
36,000 operations/hour)
100,000 operations MIN.
(under rated load, at operating frequency of
1,800 operations/hour)
※Unless otherwise specified, the above mentioned item 4 (Ratings) and
5 (Characteristics) values are under the standard conditions of
Ambient temperature 23℃ and Humidity 65%RH.
Spec No:G6A-0903024B
P. 5
6.Storage conditions
(1) Store in locations in normal temperature,humidity and atmosphere
pressure.
(2) Environments
・Store in locations where the product or container is not exposed to
corrosive gas such as hydrogen sulfide gas or salty air.
・Store in locations where no visible dust exists.
・Store in locations where the product is not exposed to the direct ray
of the sun and rain, snow.
Also please do not apply the force to product which may result
in the deformation or a change in quality of the product.
7.Operating conditions
7.1 Ambient temperature
Use the product under the following conditions.
-40 to +70℃
(without freezing or condensation)
7.2 Relative humidity
5 to 85 %RH
7.3 Mounting direction
Free
7.4 Enviroments
(1) Use in locations where the product is not exposed to corrosive gas
such as hydrogen sulfide gas or salty air.
(2) Use in locations where no visible dust exists.
(3) Use in locations where the product is not exposed to the direct ray
of the sun and rain, snow.
Also please do not apply the force to product which may result
in the deformation or a change in quality of the product.
8.Others
8.1 Weight
8.2 Impulse
Between
Between
Between
Approx. 3.5g
withstand voltage
(at10×160μs)
coil and contact
1500V
non-continuous contact
---continuous contact
----
Spec No:G6A-0903024B
P. 6
9.PRECAUTIONS
(1)Following terms are defined as below.
1)Conditions; Use conditions, rating, performance, operating environment,
handling procedure, precautions and/or prohibited use described in this
“product specifications”, documentations or manuals
2)User Application; Application of this product by a customer, including
but not limited to embedding this product into customer’s components,
electronic circuit boards, devices, equipments or systems
3)Fitness; (a)Fitness, (b)performance, (c) no infringement of intellectual
property of third party, (d) compliance with laws and regulations and
(e)conformity to various standards
(2)Note about this specification
1)The product may be discontinued or change its specification without prior
notice, unless the specification is not returned or the product is not
ordered within one year after issue of this specification. Please confirm
current specifications if you return this specification or you place an
order of this product one year after issue of this specification.
2)Rating and performance is tested separately. Combined conditions are not
warranted.
3)Reference data is intended to be used just for reference. Omron does not
warrant that the product can work properly in the range of reference
data.
4)Examples are intended for reference. Omron does not warrant the fitness
in usage of the examples.
5)Omron may, at its discretion, change factors other than rating,
performance, structure, outside dimensions or mounting dimensions.
(3)Note about adoption and use
1)Please use the product in conformance to the conditions, including rating
and performance.
2)Please confirm the fitness and decide whether or not the product is able
to be adopted in User Application.
3)Omron will not warrant any items in (1) 3)(b)~(e) of User Application
nor the fitness.
4)If you use the product in the application below, please ensure
followings; (i) allowance in aspect of rating and performance, (ii)
safety design which can minimize danger of the User Application when the
product does not work properly and (iii) periodical maintenance of the
product and the User Application.
(a)Applications requiring safety, including, without limitation, nuclear
control facilities, combustion facilities, aerospace and aviation
facilities, railroad facilities, elevating facilities, amusement
facilities, medical facilities, safety devices or other applications
which has possibility to influence lives or bodies
(b)Applications requiring high reliability, including, without limitation,
supplying systems of gas, water and electric power and applications
handling right, title, ownership or property, such as payment systems
(c)Applications in a harsh condition or environment, including, without
limitation, outdoor facilities, facilities with potential of chemical
contamination or electromagnetic interference, facilities with vibration
or impact and facilities on continual operation for a long period
(d)Applications under conditions or environment which are not described in
this specification
5)This product is not intended to be used in automotive applications
(including two wheel vehicles). Please do not use this product in the
automotive application.
Spec No:G6A-0903024B
P. 7
(4)Warranty
1)Warranty period; One year after your purchase
2)Warranty; Omron will provide, free of charge, replacements of the same
number of malfunctioning products
3)Exceptions; This warranty does not cover malfunctions caused by any of
the following.
(a)Usage in the manner other than its original purpose
(b)Usage out of the condition
(c)Cause which could not be foreseen by the level of science and technology
at the time of shipment of the product
(d)Cause outside Omron or the product, including force majeure such as
disasters
(5)The warranty described in this“conditions”is a whole and sole liability
for the products. There are no other warranties,expressed or implied.
Omron and distributors are not liable for any damages arisen from or
relating to the products.
(6)Please comply with laws and regulations of security trade control in
relevant countries if you export or provide a nonresident with the
product or technical information.
Spec No:G6A-0903024B
P.8
10.Coil
rating (table 1)
Rated
Rated
Coil
voltage
current
(V)
(m A)
(Ω)
DC 1.5
132.7
11.3
DC 3
66.7
45
DC 4.5
44.6
DC 5
Must
Must
Rated power
Maximum
resistance operate
release
consumption
Voltage
voltage
voltage
(mW)
101
70%max
10%min
40.0
125
of rated
of rated
DC 6
33.3
180
voltage
voltage
DC 9
22.2
405
DC12
16.7
720
DC24
8.3
2880
DC48
4.9
9750
200%
Approx. 200
of rated voltage
(at23℃)
Approx. 235
1: The rated current and coil resistance are measured at a coil temperature
of 23℃ with a tolerance of ±10%
2: Operating characteristics are measured at a coil temperature of 23℃.
3: The maximum coil voltage refers to the maximum value in a varying range
of operating power voltage.
11.Handling precautions
1: Please avoid micro-wave washing not to cause the internal which cause coil wire cutting
and sticking of the contact.
2:Don’
tgi
vet
her
el
aydr
oppi
ngs
hoc
kt
okeepi
ni
t
i
alper
f
or
manc
e.
3: The relay mounted on the PCB may be coated or washed but do not apply silicone coating
or detergent coating silicone, otherwise the silicone coating or detergent may remain on
the surface of the relay.
4: If wash the product after soldered the relay on PCB, please use water-based
solvent or alcohol-based solvent. At that time, please keep the solvent
temp. less than 40 degree C. Do not put the relay in a cold cleaning bath immediately
after soldering.
OMRON
Spec No:G6A-0903024B
P.9
5: In case that load is cut to two and switched in the contact of 2 pole as shown
in the figure below, the 1 and 2 pole-between mechanically becomes MBB(Make Before
Break) because of the timing-gap of the two contacts in switching, and the miss-operation
might be caused (by the short-circuit mode).
+
(short)
Lord
Contacts
-
OMRON