G6A-2-H-DC12

G6A-2-H-DC12

  • 厂商:

    OMRON(欧姆龙)

  • 封装:

    DIP8

  • 描述:

  • 数据手册
  • 价格&库存
G6A-2-H-DC12 数据手册
P.1 Number: G6A-0903024B Date of Issue: Nov.10.2011 For Reference OMRON Corporation OMRON Relay & Devices Corporation Prepared by Y.SUGA Checked by T.ASO Authorized by T.MATSUSHITA Name: MINI RELAY Model: G6A-2-H Item: DC ALL Registration part number for Customer Type name: Type number: Receipt Stamp(For receipt purpose only) Handled by Please accept handling of this specification sheet as for reference use if no reply received. Distribution Copy Revision Record Mark Date Contents Customer Sales( ) DP-720101-2C Spec No:G6A-0903024B P. 2 1.Classification Single stable relay 2.Construction 2.1 Outline dimensions Drawing No.2479484-3 2.2 Structure drawing Drawing No.-------- 2.3 Contact configuration DPDT (2c contact) 2.4 Contact structure Twin crossbar contact 2.5 Contact material 2.6 Protective construction Face material Base material Plastic sealed 3.Standards 3.1 Approved by standard(s) 3.2 Others 4.Ratings 4.1 Coil ratings (5) (6) UL CSA File No. File No. FCC Part68 :E41515 :LR31928 See table1 4.2 Contact ratings (1) Rated load (2) (3) (4) Au Alloy Ag Resistive load 125VAC 0.5A 30VDC 2A Inductive load 125VAC 0.3A (p.f.=0.4) 30VDC 1A (L/R=7ms) Rated carry current 3A Maximum rated voltage 250 VAC 220VDC Maximum rated current Resistive load AC2A DC2A Inductive load AC1A (p.f.=0.4) DC1A (L/R=7ms) Maximum switching capacity Resistive load AC125VA DC60W Inductive load AC62.5VA (p.f.=0.4) DC30W (L/R=7ms) Failure rate(reference value) DC10mV 10μA (P level)( λ =0.1×10 /ops.) 5.Characteristics(initial value) 5.1 Contact resistance 50 mΩ MAX. Measured by the voltage drop method with DC1V 10mA applied 5.2 Must operate voltage(or set voltage) See table 1 5.3 Must release voltage(or reset voltage) See table 1 5.4 Operate time (or set time) 5 ms MAX.(at rated voltage) 5.5 Release time (or reset time)3 ms MAX.(at rated voltage) 5.6 Minimum input pulse width --- ms (Applicable to latching relay only, at rated voltage) Spec No:G6A-0903024B P. 3 5.7 Insulation resistance 500VDC (1)Between coil terminals and contact terminals 1000 MΩ MIN. (2)Between non-continuous current-carrying contact terminals 1000 MΩ MIN. (3)Between contact terminals of the same polarity 1000 MΩ MIN. (4)Between set coil and reset coil ---- MΩ MIN. (5)Between current-carrying terminal and exposed non-current currying metal part. ---- MΩ MIN. 5.8 Dielectric strength(leakage current1mA 50/60Hz for a minute) (1)Between coil terminals and contact terminals AC1000 V (2)Between non-continuous current-carrying terminals AC1000 V (3)Between contact terminals of the same polarity AC750 V (4)Between set coil and reset coil AC---- V (5)Between current-carrying terminal and exposed non-current carrying metal part. AC---- V 5.9 Temperature rise (1) Coil (2) Contact 5.10 Vibration (1) Mechanical durability (2) Malfunction durability (When energized) or set status 65℃ MAX. (by the coil resistance method)at.---℃ Applied voltage of coil:100% of rated voltage---Hz Carry current of contact3A 65℃ MAX. (by the thermometer method)at.---℃ Applied voltage of coil:100% of rated voltage ---Hz Carry current of contact3A Must be free from any abnormality in both the construction and characteristics after the relay is subjected to a variable vibration of 2.5mm single amplitude(5mm double amplitude) at a vibration frequency of 10-55-10 Hz in each direction for 2 hours. Contacts must not open for 1ms or longer after the relay is subjected to a variable vibration of 1.65mm single amplitude (3.3mm double amplitude) at a vibration frequency of 10-55-10 Hz in each direction for 1 cycle. (When not energized) Contacts must not open for 1ms or reset status or longer after the relay is subjected to a variable vibration of 1.65mm single amplitude (3.3mm double amplitude) at a vibration frequency of 10-55-10 Hz in each direction for 1 cycle. 5.11 Shock (1)Mechanical durability Must be free from any abnormality in both the construction and characteristics after the relay is subjected to a shock of 1000m/s in each direction 3 times. Spec No:G6A-0903024B P. 4 (2)Malfunction durability (When energized) or set status (When not energized) or reset status Contacts must not open for1ms or longer after the relay is subjected to a shock of 500 m/s in each direction 3times. Contacts must not open for1ms or longer after the relay is subjected to a shock of 500m/s in each direction 3times. 5.12 Terminal strength Must be free from any abnormality after a tensile stress of 4.9N is applied to the terminal in any direction vertical to the terminal tip for 10 seconds. Any deformation of the terminal by the load shall not be regard as a mechanical damage. 5.13 Temperature resistance (1) Heat resistance Must be free from any abnormality in both the construction and characteristics after the relay is left in a temperature of 85±2℃ for 16 hours and then in room temperature and humidity for 2 hours. (2) Cold resistance Must be free from any abnormality in both the construction and characteristics after the relay is left in a temperature of -55±3 ℃ for 72 hours and then in room temperature and humidity for 2 hours. 5.14 Moisture resistance Must be free from any abnormality in both the construction and characteristics after the relay is left in a humidity of 90 to 95% RH for 48 hours at a temperature of 40±2℃, and then in room temperature and humidity for 2 hours. Insulation resistance, however, must be 5 MΩ MIN. 5.15 Soldering heat The product shall be free from any abnormality in both the construction and characteristics after the terminals are dipped into molten solder at 260±5℃ for 10 seconds and then left in room temperature and humidity for 2 hours or after mounted by the recommended condition of temperature profiles shown in item ---. 5.16 Endurance (1)Mechanical endurance (2)Electrical endurance 100,000,000 operations MIN. (under no load at operating frequency of 36,000 operations/hour) 100,000 operations MIN. (under rated load, at operating frequency of 1,800 operations/hour) ※Unless otherwise specified, the above mentioned item 4 (Ratings) and 5 (Characteristics) values are under the standard conditions of Ambient temperature 23℃ and Humidity 65%RH. Spec No:G6A-0903024B P. 5 6.Storage conditions (1) Store in locations in normal temperature,humidity and atmosphere pressure. (2) Environments ・Store in locations where the product or container is not exposed to corrosive gas such as hydrogen sulfide gas or salty air. ・Store in locations where no visible dust exists. ・Store in locations where the product is not exposed to the direct ray of the sun and rain, snow. Also please do not apply the force to product which may result in the deformation or a change in quality of the product. 7.Operating conditions 7.1 Ambient temperature Use the product under the following conditions. -40 to +70℃ (without freezing or condensation) 7.2 Relative humidity 5 to 85 %RH 7.3 Mounting direction Free 7.4 Enviroments (1) Use in locations where the product is not exposed to corrosive gas such as hydrogen sulfide gas or salty air. (2) Use in locations where no visible dust exists. (3) Use in locations where the product is not exposed to the direct ray of the sun and rain, snow. Also please do not apply the force to product which may result in the deformation or a change in quality of the product. 8.Others 8.1 Weight 8.2 Impulse Between Between Between Approx. 3.5g withstand voltage (at10×160μs) coil and contact 1500V non-continuous contact ---continuous contact ---- Spec No:G6A-0903024B P. 6 9.PRECAUTIONS (1)Following terms are defined as below. 1)Conditions; Use conditions, rating, performance, operating environment, handling procedure, precautions and/or prohibited use described in this “product specifications”, documentations or manuals 2)User Application; Application of this product by a customer, including but not limited to embedding this product into customer’s components, electronic circuit boards, devices, equipments or systems 3)Fitness; (a)Fitness, (b)performance, (c) no infringement of intellectual property of third party, (d) compliance with laws and regulations and (e)conformity to various standards (2)Note about this specification 1)The product may be discontinued or change its specification without prior notice, unless the specification is not returned or the product is not ordered within one year after issue of this specification. Please confirm current specifications if you return this specification or you place an order of this product one year after issue of this specification. 2)Rating and performance is tested separately. Combined conditions are not warranted. 3)Reference data is intended to be used just for reference. Omron does not warrant that the product can work properly in the range of reference data. 4)Examples are intended for reference. Omron does not warrant the fitness in usage of the examples. 5)Omron may, at its discretion, change factors other than rating, performance, structure, outside dimensions or mounting dimensions. (3)Note about adoption and use 1)Please use the product in conformance to the conditions, including rating and performance. 2)Please confirm the fitness and decide whether or not the product is able to be adopted in User Application. 3)Omron will not warrant any items in (1) 3)(b)~(e) of User Application nor the fitness. 4)If you use the product in the application below, please ensure followings; (i) allowance in aspect of rating and performance, (ii) safety design which can minimize danger of the User Application when the product does not work properly and (iii) periodical maintenance of the product and the User Application. (a)Applications requiring safety, including, without limitation, nuclear control facilities, combustion facilities, aerospace and aviation facilities, railroad facilities, elevating facilities, amusement facilities, medical facilities, safety devices or other applications which has possibility to influence lives or bodies (b)Applications requiring high reliability, including, without limitation, supplying systems of gas, water and electric power and applications handling right, title, ownership or property, such as payment systems (c)Applications in a harsh condition or environment, including, without limitation, outdoor facilities, facilities with potential of chemical contamination or electromagnetic interference, facilities with vibration or impact and facilities on continual operation for a long period (d)Applications under conditions or environment which are not described in this specification 5)This product is not intended to be used in automotive applications (including two wheel vehicles). Please do not use this product in the automotive application. Spec No:G6A-0903024B P. 7 (4)Warranty 1)Warranty period; One year after your purchase 2)Warranty; Omron will provide, free of charge, replacements of the same number of malfunctioning products 3)Exceptions; This warranty does not cover malfunctions caused by any of the following. (a)Usage in the manner other than its original purpose (b)Usage out of the condition (c)Cause which could not be foreseen by the level of science and technology at the time of shipment of the product (d)Cause outside Omron or the product, including force majeure such as disasters (5)The warranty described in this“conditions”is a whole and sole liability for the products. There are no other warranties,expressed or implied. Omron and distributors are not liable for any damages arisen from or relating to the products. (6)Please comply with laws and regulations of security trade control in relevant countries if you export or provide a nonresident with the product or technical information. Spec No:G6A-0903024B P.8 10.Coil rating (table 1) Rated Rated Coil voltage current (V) (m A) (Ω) DC 1.5 132.7 11.3 DC 3 66.7 45 DC 4.5 44.6 DC 5 Must Must Rated power Maximum resistance operate release consumption Voltage voltage voltage (mW) 101 70%max 10%min 40.0 125 of rated of rated DC 6 33.3 180 voltage voltage DC 9 22.2 405 DC12 16.7 720 DC24 8.3 2880 DC48 4.9 9750 200% Approx. 200 of rated voltage (at23℃) Approx. 235 1: The rated current and coil resistance are measured at a coil temperature of 23℃ with a tolerance of ±10% 2: Operating characteristics are measured at a coil temperature of 23℃. 3: The maximum coil voltage refers to the maximum value in a varying range of operating power voltage. 11.Handling precautions 1: Please avoid micro-wave washing not to cause the internal which cause coil wire cutting and sticking of the contact. 2:Don’ tgi vet her el aydr oppi ngs hoc kt okeepi ni t i alper f or manc e. 3: The relay mounted on the PCB may be coated or washed but do not apply silicone coating or detergent coating silicone, otherwise the silicone coating or detergent may remain on the surface of the relay. 4: If wash the product after soldered the relay on PCB, please use water-based solvent or alcohol-based solvent. At that time, please keep the solvent temp. less than 40 degree C. Do not put the relay in a cold cleaning bath immediately after soldering. OMRON Spec No:G6A-0903024B P.9 5: In case that load is cut to two and switched in the contact of 2 pole as shown in the figure below, the 1 and 2 pole-between mechanically becomes MBB(Make Before Break) because of the timing-gap of the two contacts in switching, and the miss-operation might be caused (by the short-circuit mode). + (short) Lord Contacts - OMRON
G6A-2-H-DC12 价格&库存

很抱歉,暂时无法提供与“G6A-2-H-DC12”相匹配的价格&库存,您可以联系我们找货

免费人工找货