G6B
PCB Power Relay
High Capacity and High
Dielectric Strength Miniature
Relay with Fully Sealed
Construction in 5 A (8 A)
SPST-NO(1a),
SPST-NO+SPST-NC(1a1b),
DPST-NO(2a),
DPST-NC(2b) Types
• P6B model for connecting sockets are available.
• High insulation with dielectric strength of 3,000VAC
between coil and contacts (impulse withstand voltage of
6 kV).
G
6
B
• Standard model conforms to UL/CSA standards.
• AgSnIn contacts suitable for loads that generate surge voltage (inductive load, capacity load, etc.) are available. (-FD type)
• Ultrasonic cleanable models are available. (-U type)
• Operation indicator & built-in surge absorption diode models are available. (-ND type)
• 2-Pole type available.
• High-reliability models are available.
G6B-1184P-US model (The relay used in Terminal Relay G6B-48BND)
■Application Examples
RoHS Compliant
• Ideal for output applications of control equipments
■Model Number Legend
G6B @ - @ @ @ @ @ -@ - @ -@ - @ -@ - @
1
2
3 4 5
6
7
1. Relay Function
None: Single-side stable
U : Single-winding latching
(G6B@-1114 models only)
K : Double-winding latching
(G6B@-1114 models only)
2. Contact Form
21: SPST-NO + SPST-NC
22: DPST-NO
20: DPST-NC
11: SPST-NO
3. Classification
1: Standard
7: High-capacity
8: Single crossbar
8
9 10 11
4. Enclosure rating
4: Fully sealed
7: Flux protection
5. Terminal Shape
P: Straight PCB terminals
Socket mounting terminals
C: Self-clinching PCB
6. Contact material
None: Standard (Ag-alloy (Cd free))
FD : AgSnIn contact
(Suitable for DC inductive load with
high inrush current)
7. Coil Polarity
None: 5, 6 Terminal (+), 1, 2 Terminal (-)
1 : 5, 6 Terminal (-), 1, 2 Terminal (+)
8. Operation Indicator Diode
Availability
None: Standard
ND : Operation indicator & coil surge
absorption diode
(for -1177 type only)
9. Approved Standards
US: UL/CSA
10. Washability
None: Standard
U : For ultrasonically cleanable
11. Mounting
None: Mounted directly to PCB
P6B : Mounted to Socket
1
G6B
PCB Power Relay
■Ordering Information
● Standard Models (UL, CSA certified)
Number
of poles
Contact material
Relay Function
Contact form
SPST-NO (1a)
(Standard)
Single-side
stable
SPST-NO (1a)
(High-capacity)
SPST-NO (1a)
(High-reliability )
1-pole
Straight PCB
Standard (Ag-alloy (Cd free))
Model
5, 6, 12, 24 VDC
Self-clinching
G6B-1114C-US
PCB
5, 6, 12, 24 VDC
G6B-1114C-FD-US
12, 24 VDC
Straight PCB
5, 6, 12, 24 VDC
G6B-1174P-FD-US
5, 6, 12, 24 VDC
Self-clinching
G6B-1174C-US
PCB
5, 12, 24 VDC
G6B-1174C-FD-US
5, 12, 24 VDC
Straight PCB
5, 12, 24 VDC
Self-clinching
PCB
Straight PCB
G6B-1174P-US
G6B-1184P-US
--G6BU-1114P-US
SPST-NO (1a)
(Standard)
Single-side
stable
SPST-NO (1a)
Straight PCB G6B-1177P-ND-US
(Built-in highcapacity operation Self-clinching G6B-1177C-ND-US
indicator & diode) PCB
DPST-NO (2a)
(Standard)
DPST-NC (2b)
(Standard)
Minimum
Rated coil voltage packing unit
G6B-1114P-FD-US
Double-winding
latching
Single-side
stable
AgSnIn contact
Model
5, 6, 12, 24 VDC
SPST-NO (1a)
(Standard)
SPST-NO (1a)+
SPST-NC (1b)
(Standard)
Rated coil voltage
G6B-1114P-US
Single-winding
latching
G
6
B
2-pole
Terminals
--5, 6, 12, 24 VDC
---
---
---
---
G6BU-1114P-FD-US
12 VDC
Straight PCB
G6BK-1114P-US
5, 6, 12, 24 VDC
G6BK-1114P-FD-US
5, 6, 12, 24 VDC
Self-clinching
G6BK-1114C-US
PCB
5, 6, 12, 24 VDC
G6BK-1114C-FD-US
24 VDC
5, 12, 24 VDC
G6B-1177P-FD-ND-US
5, 12, 24 VDC
5, 12, 24 VDC
G6B-1177C-FD-ND-US 12, 24 VDC
G6B-2114P-US
---
---
5, 6, 12, 24 VDC
G6B-2114P-FD-US
5, 6, 12, 24 VDC
Self-clinching
G6B-2114C-US
PCB
5, 12, 24 VDC
G6B-2114C-FD-US
5, 12 VDC
Straight PCB
G6B-2214P-US
20
pcs/tube
5, 12, 24 VDC
Self-clinching
G6BU-1114C-US
PCB
Straight PCB
100
pcs/tray
5, 6, 12, 24 VDC
G6B-2214P-FD-US
5, 6, 12, 24 VDC
Self-clinching
G6B-2214C-US
PCB
5, 12, 24 VDC
G6B-2214C-FD-US
5, 12, 24 VDC
Straight PCB
G6B-2014P-US
5, 6, 12, 24 VDC
G6B-2014P-FD-US
5, 6, 12, 24 VDC
Self-clinching
G6B-2014C-US
PCB
5, 6, 12, 24 VDC
G6B-2014C-FD-US
12, 24 VDC
100
pcs/tray
Note: AgSnIn contact models are highly welding-resistant, and roughening of contacts due to inrush current and inductive load is lessened.
● Models for Reverse Coil Polarity
Number
of poles
Contact material
Relay Function
Contact form
SPST-NO (1a)
(Standard)
Single-side
stable
SPST-NO (1a)
(High-capacity)
1-pole
2-pole
Single-winding
latching
SPST-NO (1a)
(Standard)
Double-winding
latching
SPST-NO (1a)
(Standard)
Single-side
stable
SPST-NO (1a)+
SPST-NC (1b)
(Standard)
DPST-NO (2a)
(Standard)
Terminals
Straight PCB
Self-clinching
PCB
Straight PCB
Self-clinching
PCB
Straight PCB
Self-clinching
PCB
Straight PCB
Self-clinching
PCB
Straight PCB
Self-clinching
PCB
Straight PCB
Self-clinching
PCB
Standard (Ag-alloy (Cd free))
Model
G6B-1114P-1-US
--G6B-1174P-1-US
--G6BU-1114P-1-US
--G6BK-1114P-1-US
--G6B-2114P-1-US
--G6B-2214P-1-US
---
Rated coil voltage
5, 6, 12, 24 VDC
---
AgSnIn contact
Model
G6B-1114P-FD-1-US
Minimum
Rated coil voltage packing unit
24 VDC
---
---
---
---
---
---
---
---
---
---
---
5, 6, 12, 24 VDC
---
---
---
---
---
5, 12, 24 VDC
--5, 12 VDC
5, 6, 12, 24 VDC
--5, 12, 24 VDC
---
G6B-2114P-FD-1-US
12, 24 VDC
---
---
---
---
---
---
Note: AgSnIn contact models are highly welding-resistant, and roughening of contacts due to inrush current and inductive load is lessened.
2
100
pcs/tray
20
pcs/tube
100
pcs/tray
G6B
PCB Power Relay
● Models for Ultrasonically Cleanable
Number
of poles
1-pole
Contact material
Relay Function
Contact form
Single-side
stable
SPST-NO (1a)
(Standard)
Single-winding
latching
SPST-NO (1a)
(Standard)
Double-winding
latching
SPST-NO (1a)
(Standard)
SPST-NO (1a)+
SPST-NC (1b)
(Standard)
2-pole
Single-side
stable
DPST-NO (2a)
(Standard)
DPST-NC (2b)
(Standard)
Terminals
Straight PCB
Standard (Ag-alloy (Cd free))
Model
Rated coil voltage
G6B-1114P-US-U
5, 6, 12, 24 VDC
AgSnIn contact
Model
G6B-1114P-FD-US-U
Minimum
Rated coil voltage packing unit
6, 12, 24 VDC
Self-clinching
G6B-1114C-US-U
PCB
5, 12, 24 VDC
---
---
Straight PCB
24 VDC
---
---
---
---
---
5, 6, 12, 24 VDC
G6BK-1114P-FD-US-U
Self-clinching
PCB
Straight PCB
G6BU-1114P-US-U
--G6BK-1114P-US-U
Self-clinching
G6BK-1114C-US-U
PCB
24 VDC
Straight PCB
5, 12, 24 VDC
Self-clinching
PCB
Straight PCB
G6B-2114P-US-U
---
G6B-2114P-FD-US-U
---
G6B-2214P-US-U
5, 6, 12, 24 VDC
Self-clinching
G6B-2214C-US-U
PCB
12, 24 VDC
Straight PCB
5, 12, 24 VDC
Self-clinching
PCB
---
G6B-2014P-US-U
---
--G6B-2214P-FD-US-U
--G6B-2014P-FD-US-U
---
---
12, 24 VDC
--5, 12, 24 VDC
100
pcs/tray
--5, 12, 24 VDC
--5, 12, 24 VDC
---
Note: When ordering, add the rated coil voltage to the model number.
Example: G6B-1114P-US DC5
Rated coil voltage
However, the notation of the coil voltage on the product case as well as on the packing will be marked as @@ VDC.
G
6
B
● Connecting Sockets (Sold Separately)
Applicable relay
Model
G6B-1114P(-FD)-US-P6B
G6B-1174P(-FD)-US-P6B
G6B-1177P(-FD)-ND-US-P6B
G6BU-1114P-US-P6B
P6B-04P
G6BK-1114P-US-P6B
P6B-06P
G6B-2114P-US-P6B
G6B-2214P-US-P6B
G6B-2014P-US-P6B
P6B-26P
Removal Tool
P6B-Y1
Hold-down Clips
P6B-C2
Minimum ordering unit
20 pcs
1 pcs
Note 1. G6B-1174P-US-P6B and G6B-1177P-ND-US-P6B are rated for 8 A when mounted on a PCB. However,
when used with the P6B-04P socket models, the allowable current is derated to 5 A.
2. The P6B sockets are designed to be used with G6B-@@@@P(-FD)-US-P6B relays. Only use G6B relays
that include "-P6B" in their model numbers with the sockets. Do not use standard G6B's that omit "-P6B"
from their model numbers with the sockets.
3. The hold-down clips of the P6B-C2 model are not suitable for the G6B-1174P and G6B-1177P models
since they have different heights.
4. Products with UL/CSA certification marks will be supplied for orders of standard models.
3
G6B
PCB Power Relay
■Ratings
● Coil: 1-Pole, Single-side Stable Type (Including models for ultrasonically cleanable)
Item
Rated voltage
Rated current Coil resistance
(mA)
(Ω)
5 VDC
40
125
6 VDC
33.3
180
12 VDC
16.7
720
24 VDC
8.3
2,880
Must operate Must release
voltage (V)
voltage (V)
Max. voltage
Power consumption
(V)
(mW)
% of rated voltage
70% max.
160%
(at 23°C)
10% min.
Approx. 200
● Coil: 2-Pole, Single-side Stable Type (Including models for ultrasonically cleanable)
Item
Rated voltage
Rated current Coil resistance
(mA)
(Ω)
5 VDC
60
6 VDC
50
120
12 VDC
25
480
24 VDC
12.5
Must operate Must release
voltage (V)
voltage (V)
Max. voltage
Power consumption
(V)
(mW)
% of rated voltage
83.3
80% max.
140%
(at 23°C)
10% min.
Approx. 300
1,920
● Coil: Single-winding Latching Type (Including models for ultrasonically cleanable)
Item
Rated
current
(mA)
Rated voltage
G
6
B
Coil
resistance
(Ω)
5 VDC
40
125
6 VDC
33.3
180
12 VDC
16.7
720
24 VDC
8.3
2,880
Must set Must reset Max. voltage
voltage (V) voltage (V)
(V)
% of rated voltage
70% max.
Power consumption
Set coil
(mW)
Reset coil
(mW)
200
200
160%
(at 23°C)
70% max.
● Coil: Double-winding Latching Type (Including models for ultrasonically cleanable)
Rated current (mA)
Item
Rated voltage
Set coil
Must set voltage Must reset voltage Max. voltage
(V)
(V)
(V)
Coil resistance (Ω)
Reset coil
Set coil
Reset coil
5 VDC
56
56
89.2
89.2
6 VDC
46.8
46.8
128.5
128.5
12 VDC
23.3
23.3
515
515
24 VDC
11.7
11.7
2,060
2,060
% of rated voltage
70% max.
130%
(at 23°C)
70% max.
Power consumption
Set coil
(mW)
Reset coil
(mW)
280
280
● Coil: Operation Indicator Model (Flux-resistant type. Do not wash down with water.)
Item
Rated voltage
Rated current Coil resistance
(mA)
(Ω)
43
116
12 VDC
5 VDC
19.7
610
24 VDC
11.3
2,120
Must operate Must release
voltage (V)
voltage (V)
Max. voltage
Power consumption
(V)
(mW)
% of rated voltage
70% max.
10% min.
130%
(at 23°C)
Approx. 200
Approx. 240
Approx. 275
Note 1. The rated current and coil resistance are measured at a coil temperature of 23°C with a tolerance of ±10%.
2. The operating characteristics are measured at a coil temperature of 23°C.
3. The “Max. voltage” is the maximum voltage that can be applied to the relay coil.
● Contacts
Model
Load
Item
G6B-1114P(-FD)(-1)-US
G6BU-1114P(-FD)(-1)-US
G6BK-1114P(-FD)(-1)-US
G6B-1114C(-FD)-US
G6BU-1114C-US
G6BK-1114C(-FD)-US
Resistive load
Inductive load
(cosφ = 0.4; L/R = 7 ms)
Contact type
Contact material
Rated load
Rated carry current
G6B-1174P(-FD)(-1)-US
G6B-1177P(-FD)-ND-US
G6B-1174C(-FD)-US
G6B-1177C(-FD)-ND-US
Resistive load
Inductive load
(cosφ = 0.4; L/R = 7 ms)
Resistive load
Inductive load
(cosφ = 0.4; L/R = 7 ms)
Single crossbar
Single
Au-alloy + Ag (Cd free)
Ag-Alloy (Cd free)
2 A at 250 VAC
2 A at 30 VDC
8 A (5 A)
0.5 A at 250 VAC 5 A (3 A) at 250 VAC 1.5 A (1.5 A) at 250 VAC
0.5 A at 30 VDC 5 A (3 A) at 30 VDC 1.5 A (1.5 A) at 30 VDC
2A
5 A (5 A)
2A
5 A (5 A)
380 VAC, 125 VDC
5 A (5 A)
8 A (5 A)
Note 1. The values in the parentheses ( ) are for -FD models only.
2. Use the -FD type for inductive load and switching load which contact roughening is small.
4
Inductive load
(cosφ = 0.4; L/R = 7 ms)
Single
Max. switching voltage
Max. switching current
Resistive load
Ag-Alloy (Cd free)
5 A (3 A) at 250 VAC 2 A (2 A) at 250 VAC 8 A (5 A) at 250 VAC 2 A (2 A) at 250 VAC
5 A (3 A) at 30 VDC 2 A (2 A) at 30 VDC 8 A (5 A) at 30 VDC 2 A (2 A) at 30 VDC
5 A (5 A)
G6B-1184P-US
G6B-2114P(-FD)(-1)-US
G6B-2214P(-FD)(-1)-US
G6B-2014P(-FD)-US
G6B-2114C(-FD)-US
G6B-2214C(-FD)-US
G6B-2014C(-FD)-US
G6B
PCB Power Relay
■Characteristics
G6B-1114P(-FD)(-1)-US
G6B-1174P(-FD)(-1)-US
Model
G6B-1114C(-FD)-US
G6B-1174C(-FD)-US
Item
Classification
G6BU-1114P(-FD)(-1)-US
G6BU-1114C-US
G6BK-1114P(-FD)(-1)-US
G6BK-1114C(-FD)-US
G6B-1177P(-FD)-ND-US
G6B-1177C(-FD)-ND-US
G6B-1184P-US
G6B-2114P(-FD)(-1)-US
G6B-2214P(-FD)(-1)-US
G6B-2014P(-FD)(-1)-US
G6B-2114C(-FD)-US
G6B-2214C(-FD)-US
G6B-2014C(-FD)-US
Single-winding
Double-winding
Built-in operation indicator
Single-side stable
Single-side stable
latching
latching
& surge absorption diode
30 mΩ max.
50 mΩ max.
30 mΩ max.
10 ms max.
10 ms max.
−
15 ms (at 23°C)
−
−
15 ms (at 23°C)
−
1,000 MΩ min.
2,000 VAC,
3,000 VAC, 50/60 Hz for 1 min
3,000 VAC, 50/60 Hz for 1 min
50/60 Hz for 1 min
Single-side stable
Contact resistance *1
Operate (set) time
Release (reset) time
Min. set pulse width
Min. reset pulse width
Insulation resistance *2
Between coil and
contacts
Between contacts
Dielectric of the same polarity
strength
Between contacts
of different polarity
Between set and
−
reset coils
Impulse withstand voltage
6 kV 1.2 × 50 μs
(between coil and contacts)
Destruction
Vibration
resistance Malfunction
Destruction
Shock
resistance Malfunction
100 m/s2
Mechanical
Durability
Electrical
Failure rate (P level)
(reference value) *3
Ambient operating temperature
Ambient operating humidity
Weight
Approx. 3.5 to 4.6 g
1,000 VAC, 50/60 Hz for 1 min
2,000 VAC,
50/60 Hz for 1 min
−
250 VAC,
50/60 Hz for 1 min
4.5 kV 1.2 × 50 μs
−
6 kV 1.2 × 50 μs
−
6 kV 1.2 × 50 μs
10 to 55 to 10 Hz, 0.75 mm single amplitude (1.5 mm double amplitude)
10 to 55 to 10 Hz, 0.75 mm single amplitude (1.5 mm double amplitude)
1,000 m/s2
300 m/s2
100 m/s2
50,000,000 operations min. (at 18,000 operations/hr)
100,000 operation min. (at 1,800 operations/hr under rated load)
10 mA at 5 VDC
Approx. 3.5 g
-25°C to 70°C (with no icing or condensation)
5% to 85%
Approx. 3.7 g
Approx. 5.4 g
G
6
B
1 mA at 1 VDC
10 mA at 5 VDC
Approx. 3.5 g
Approx. 4.5 g
Note 1. The values here are initial values.
2. The G6B-1177P(-FD)-ND model is flux-resistant. Do not wash it down with water.
*1. The contact resistance was measured with 1 A at 5 VDC using a voltage-drop method.
*2. Measurement conditions: The insulation resistance was measured with a 500 VDC megohmmeter at the same locations as the dielectric strength was
measured.(Except the location between set/reset coil)
*3. This value was measured at a switching frequency of 120 operations/min.
5
G6B
PCB Power Relay
■Engineering Data
20
AC resistive load
5
3
2
50
30
AC resistive load
10
8
5
AC
inductive
load
cosφ = 0.4
DC inductive load
(L/R = 7 ms)
1
100
3
2
DC resistive load
0.5
0.3
0.1
0.1
3
5
10
20 30
100
300 500
3
5
10
30 50 100
Durability (x104 operations)
Durability (x104 operations)
300
G6B-1174P-FD-US
250 VAC/30 VDC resistive load
100
G6B-1174P-US
250 VAC/30 VDC
resistive load
50
30
AC inductive load
(cosφ = 0.4)
AC resistive
load
AC
resistive
load
DC resistive load
DC inductive load
(L/R = 7 ms)
380
0
1,000
3
5
10
30 50 100
Switching voltage (V)
1,000
G6B-2114P(-FD)-US
500 G6B-2214P(-FD)-US
300 G6B-2014P(-FD)-US
250 VAC/30 VDC inductive load
(cosφ = 0.4, L/R = 7 ms)
100
G6B-2114P-US
G6B-2214P-US
G6B-2014P-US
250 VAC/30 VDC resistive load
50
30
300 500 1,000
Switching voltage (V)
● Ambient Temperature vs.
Maximum Coil Voltage
G6B-1114P-US
G6B-2114P-US
G6B-1174P-US
G6B-2214P-US
G6B-1174P-FD-US
G6B-2014P-US
G6B-2114P(-FD)-US
G6B-2214P(-FD)-US
G6B-2014P(-FD)-US
G6B-1114P-US
250 VAC/30 VDC resistive load
500
10
0.1
0
1,000
200
180
G6B-1114P-US
G6B-1174P-US
G6B-1174P-FD-US
160
140
130
120
10
110
10
5 G6B-1114P-US
G6B-1174P-FD-US
3 G6B-1174P-US
250 VAC/30 VDC inductive load
(cosφ = 0.4, L/R = 7 ms)
1
0
1
2
3
4
5
6
G6B-2114P-FD-US
G6B-2214P-FD-US
G6B-2014P-FD-US
250 VAC resistive load
5
3
80
1
7
G6B-2114P-US
G6B-2214P-US
G6B-2014P-US
100
Higher
capacity
8
9
10
60
0
1 1.5 2
3
4
5
Switching current (A)
6
7
8
9
10
0
20 23 30
40
50
60
70
80
90
Ambient temperature (°C)
Switching current (A)
Note: The maximum coil voltage refers to the
maxi-mum value in a varying range of
operating power voltage, not a continuous
voltage.
2.54 mm
max.
X
min.
Sample
60
De-energized
max.
40
Sample
X
min.
20
Energized
−20
0
20
40
60
80
Ambient temperature (°C)
6
Change rate on the
basis of initial value (%)
Must operate voltage
Must release voltage
80
0
−40
G6B-1114P-US
Must operate voltage
Must release voltage
Must operate voltage
Must release voltage
+1.0
Initial stage
Test
Change rate on the
basis of initial value (%)
Sample:
G6B-1114P-US
Number of Relays: 5 pcs
G6B-1114P-US
Change rate on the
basis of initial value (%)
100
● Mutual Magnetic Interference
+0.5
2.54 mm
0
−0.5
−1.0
+1.0
Average value
Sample
De-energized
Initial stage
Test
+0.5
Sample
0
−0.5
−1.0
Average value
Energized
Initial stage
+1.0
Test
+0.5
0
−0.5
−1.0
Average value
Initial stage
Change rate on the
basis of initial value (%)
● Ambient Temperature vs. Must
Operate and Must Release Voltage
G6B-1114P-US
Must-operate/must-release voltage (%)
G
6
B
G6B-2114P-FD-US
G6B-2214P-FD-US
G6B-2014P-FD-US
0.3
Switching voltage (V)
● Durability
G6B-1114P-US
G6B-1174P-US
G6B-1174P-FD-US
30
0.5
DC inductive load
Maximum coil voltage (%)
0
50
3
2
1.5
1
AC
inductive
load
1
0.3
0.2
100
5
DC resistive load
0.5
Switching current (A)
40
10
G6B-2114P-US
G6B-2214P-US
G6B-2014P-US
G6B-1174P-US
Switching current (A)
Switching current (A)
● Maximum Switching Current
G6B-1114P-US
G6B-1174P-FD-US
+1.0
Test
+0.5
0
−0.5
−1.0
Average value
G6B
PCB Power Relay
● Shock Malfunction
Y
1,000
Y
Energized
Y
Energized
Reset
1,000
Set
300
X
400
X
1,000
Z
100
200
Z
1,000
700
600
200
100
400
X'
300
Z'
X
1,000
Z
1,000
300
1,000
Z'
1,000
X'
1,000
Z'
1,000
X'
300
Unit: m/s2
1,000
Y'
Y'
Y'
1,000
Y'
Unit: m/s2
Sample: G6B-1174P-US
G6B-1174P-FD-US
Test Conditions: Shock is applied in ±X, ±Y,
and ±Z directions three times each with without
energizing the Relays
Shock direction
X
X'
to check the number of
Y
malfunctions.
Z
Requirement: None
Z'
malfuction 100 m/s2
Sample: G6B-1114P-US
Number of Relays: 12 pcs
Test Conditions: Shock is applied in ±X, ±Y,
and ±Z directions three times each with without
energizing the Relays
Shock direction
X
X'
to check the number of
Y
malfunctions.
Z
Requirement: None
Z'
malfuction 100 m/s2
Y'
(Coil)
Unit: m/s2
Sample: G6BK-1114P-US
Number of Relays: 12 pcs
Test Conditions: The value at which
malfunction occurred was measured after
applying shock to the
Shock direction
X
X'
test piece 3 times each
Y
in 6 directions along 3
Z
axes.
Z'
Standard value:
300 m/s2
Y'
(Coil)
(Coil)
Sample: G6B-1114P-US
G6B-1174P-FD-US
Number of Relays: 10 pcs
30 Test: the variation of operating voltage is measured
based on cold start at 23°C, during which rated
voltage is applied to the coil with rated
20 contact current (5A), and left for 1
hour each under different
ambient
temperatures.
120% applied
10
40
Sample: G6B-1174P-US
Test: the variation of operating voltage is measured
30 based on cold start at 23°C, during which rated
voltage is applied to the coil with rated contact
current (8A), and left for 1 hour
each under different ambient
20 temperatures.
120% applied
110% applied
10
110% applied
0
−20
0
20
40
60
120% applied
0
−10
−10
−20
−50
80 100
−40
−20
0
20
40
60
−20
−50
80 100
110% applied
100% applied
−40
−20
0
20
Ambient temperature (°C)
Ambient temperature (°C)
G
6
B
10
0
100% applied
−40
40 Sample: G6B-2114P-US
G6B-2214P-US
G6B-2014P-US
30 Test: the variation of operating voltage is
measured based on coil cold start at 23°C, during
which rated voltage is applied to the coil with rated
20 contact current (5A), and left
for 1 hour each under different
ambient temperatures.
100% applied
−10
−20
−50
Rate of variability (%)
40
Rate of variability (%)
Rate of variability (%)
● Hot Start
40
60
80 100
Ambient temperature (°C)
■Dimensions
(Unit: mm)
1-pole Single-side Stable Models (SPST-NO(1a))
Straight PCB
G6B-1114P(-FD)(-1)-US
10 max.
G6B-1184P-US
10 max.
(9.8)*
(9.8)* 0.3
3.5
0.85 0.9
0.5
0.9
PCB Mounting Holes
(BOTTOM VIEW)
Tolerance: ±0.1 mm
0.5
20 max.
(19.9)*
2.54
* Average value
Dimensions in pointed brackets < > are for the
Relay mounted to Socket.
Terminal Arrangement/
Internal Connections
(BOTTOM VIEW)
Four, 1.1-dia. holes
2.54
(1.2)
1
3
Self-clinching PCB
G6B-1114C(-FD)-US
4
6
10.16
10 max.
(9.8)*
10 max.
(9.8)* 0.3
(1.1)
(1.0)
3.2
7.62
Note: Check carefully the coil
polarity of the Relay. Polarity in
the parenthesis is the models for
reverse coil polarity.
Note: Orientation marks are indicated as follows:
3.5
0.85 0.9
0.5
(0.8)
0.5
0.9
20 max.
(19.9)*
* Average value
7
G6B
PCB Power Relay
1-pole Single-side Stable Models (SPST-NO(1a))
Straight PCB
G6B-1174P(-FD)(-1)-US
10 max.
(9.9)*
12.5 max.
(12.45)* 0.65
3.5
PCB Mounting Holes
(BOTTOM VIEW)
Tolerance: ±0.1 mm
0.85 0.9
0.45
0.9
Terminal Arrangement/
Internal Connections
(BOTTOM VIEW)
0.5
20.2 max.
(20.0)*
2.54
Four, 1.1-dia. holes
* Average value
Dimensions in pointed brackets < > are for the
Relay mounted to Socket.
2.54
(1.2)
1
3
Self-clinching PCB
G6B-1174C(-FD)-US
4
6
10 max.
(9.9)*
10.16
7.62
(1.2)
12.5 max.
(12.45)* 0.65
(1.0)
3.2
Note: Check carefully the coil
polarity of the Relay. Polarity in
the parenthesis is the models for
reverse coil polarity.
Note: Orientation marks are indicated as follows:
3.5
0.85 0.9
0.45
(0.8)
0.5
0.9
20.2 max.
(20.0)*
* Average value
1-pole Single-winding Latching Model (SPST-NO(1a))
G Straight PCB
6 G6BU-1114P(-1)-US
B
10 max.
(9.8)*
10 max.
(9.8)* 0.3
3.5
PCB Mounting Holes
(BOTTOM VIEW)
Tolerance: ±0.1 mm
0.85 0.9
0.5
0.5
0.9
20 max.
(19.9)*
Terminal Arrangement/
Internal Connections
(BOTTOM VIEW)
2.54
* Average value
Dimensions in pointed brackets < > are for the
Relay mounted to Socket.
Four, 1.1-dia. holes
2.54
(1.2)
1
3
S R
4
6
Self-clinching PCB
G6BU-1114C-US
10 max.
(9.8)*
10.16
7.62
(1.1)
10 max.
(9.8)* 0.3
(1.0)
Note: Orientation marks are indicated as follows:
3.2
3.5
0.85 0.9
0.5
(0.8)
0.5
0.9
20 max.
(19.9)*
* Average value
1-pole Double-winding Latching Model (SPST-NO(1a))
Straight PCB
G6BK-1114P(-FD)(-1)-US
10 max.
(9.8)*
10 max.
(9.8)* 0.3
PCB Mounting Holes
(BOTTOM VIEW)
Tolerance: ±0.1 mm
3.5
0.85
0.85
0.5
0.9
Note: Check carefully the coil
polarity of the Relay. Polarity in
the parenthesis is the models
for reverse coil polarity.
S: Set coil
R: Reset coil
0.9
0.5
2.54
20 max.
(19.9)*
Terminal Arrangement/
Internal Connections
(BOTTOM VIEW)
Six, 1.1-dia. holes
* Average value
2.54
Dimensions in pointed brackets < > are for the
Relay mounted to Socket.
(1.2)
1
6
Self-clinching PCB
G6BK-1114C(-FD)-US
10 max.
(9.8)*
2.54
7.62
7.62
(1.1)
10 max.
(9.8)* 0.3
(1.0)
0.85
0.5
8
0.85
0.9
20 max.
(19.9)*
0.9
R
3
(0.8)
0.5
* Average value
4
5
Note: Check carefully the coil
polarity of the Relay. Polarity in
the parenthesis is the models
for reverse coil polarity.
S: Set coil
R: Reset coil
Note: Orientation marks are indicated as follows:
3.2
3.5
2
S
G6B
PCB Power Relay
1-pole Single-side stable Models (SPST-NO (1a)) (Built-in high capacity operation indicator & surge absorption diode)
Straight PCB
20.2 max.
0.45
G6B-1177P(-FD)-ND-US
(20)*
3.7
1.7
10 max.
(9.9)*
1.6
LED
0.3
15 max.
(14.8)*
0.65
3.5
Terminal Arrangement/
Internal Connections
(BOTTOM VIEW)
PCB Mounting Holes
(BOTTOM VIEW)
Tolerance: ±0.1 mm
0.85 0.9
10.16
0.9
0.5
Four, 1.1-dia. holes
2.54
7.62
7.62
* Average value
Dimensions in pointed brackets < > are for the
Relay mounted to Socket.
Self-clinching PCB
G6B-1177C(-FD)-ND-US
1
3
2.54
4
7.62
6
(1.2)
0.45
20.2 max.
(20)*
(1.11)
10.16
3.7
Note: The G6B-1177P-ND-US model has a flux-resistant
construction. Do not wash it down with water. Pay
attention to the polarity of the coil since the LED and
surge absorption diode are built-in.
1.7
10 max.
(9.9)*
1.6
7.62
Note: Check carefully the
coil polarity of the Relay.
G
6
B
LED
0.3
15 max.
(14.8)*
0.65
(1.0)
3.2
3.5
0.85 0.9
10.16
(0.8)
0.5
0.9
7.62
7.62
* Average value
2-poles Single-side stable Models (SPST-NO (1a) + SPST-NC (1b), DPST-NO (2a), DPST-NC(2b))
Straight PCB
20 max.
(19.9)*
G6B-2114P(-FD)(-1)-US
G6B-2214P(-FD)(-1)-US
11 max.
(10.9)*
G6B-2014P(-FD)-US
PCB Mounting Holes
(BOTTOM VIEW)
Tolerance: ±0.1 mm
Terminal Arrangement/
Internal Connections
(BOTTOM VIEW)
11 max.
(10.9)*
Six, 1.1-dia. holes
2.54
3.5
G6B-2114
0.9
10.16
0.4
2.54
7.62
7.62
1
3
4
8
6
5
7.62
* Average value
Dimensions in pointed brackets < > are for the
Relay mounted to Socket.
(1.7)
(1.11)
Self-clinching PCB
G6B-2114C(-FD)-US
G6B-2214C(-FD)-US
G6B-2014C(-FD)-US
20 max.
(19.9)*
10.16
7.62
G6B-2014
1
3
4
8
6
5
11 max.
(10.9)*
G6B-2214
11 max.
(10.9)*
(1.0)
3.2
3.5
7.62
3
4
8
6
5
Note: Check carefully the coil
polarity of the Relay. Polarity in
the parenthesis is the models
for reverse coil polarity.
(0.8)
0.3
0.8
10.16
1
7.62
* Average value
9
G6B
PCB Power Relay
■Connecting Sockets Dimensions
Socket for 1-pole Single-winding Latching Model and
Single-side Stable Model
23.2 max.
P6B-04P
PCB Mounting Holes
(BOTTOM VIEW)
Tolerance: ±0.1 mm
(23)*
10 max.
(9.9)*
Four, 1.1-dia. holes
2.54
3.1
2.54
(1.2)
10.1 max.
(10)* 7
(2.71)
3.5
0.8
10.16
10.16
7.62
0.4
7.62
7.62
* Average value
Socket for 1-pole Double-winding Latching Model
P6B-06P
23.2 max.
PCB Mounting Holes
(BOTTOM VIEW)
Tolerance: ±0.1 mm
(23)*
10 max.
(9.9)*
3.1
Six, 1.1-dia. holes
2.54
2.54
G
6
B
(1.2)
10.1 max.
(10)* 7
3.5
(2.71)
0.8
2.54
7.62
7.62
7.62
7.62
2.54
0.4
7.62
* Average value
Socket for Double-pole Single-side Stable
P6B-26P
PCB Mounting Holes
(BOTTOM VIEW)
Tolerance: ±0.1 mm
23.2 max.
(23)*
11 max.
(10.8)*
3.1
Six, 1.1-dia. holes
2.54
2.54
10.1 max.
(10)* 7
(1.6)
3.5
0.8
10.16
7.62
0.4
(2.61)
10.16
7.62
7.62
* Average value
■Removal Tool
■Hold-down Clips
■Related Products
P6B-Y1
P6B-C2
The G6B-4 Terminal Relay series with
4-point output is also available.
For details, contact your OMRON sales
representative.
10
G6B
PCB Power Relay
■Approved Standards
• The approval rating values for overseas standards are different from the performance values determined individually. Confirm the
values before use.
UL Recognized:
(File No. E41643)
Contact
Coil ratings
form
Model
Contact ratings
5 A, 250 VAC (General Use) 80°C
G6B-1114P(-FD)(-1)-US
G6B-1114C(-FD)-US
1
3 to 24
VDC
5 A, 30 VDC (Resistive) 80°C
1/8HP, 250 VAC 80°C
1/6HP, 250 VAC 80°C
G6B-1174P(-FD)(-1)-US
G6B-1174C(-FD)-US
1
3 to 24
VDC
8 A, 277 VAC (General Use) 80°C
G6B-1184P-US
1
3 to 24
VDC
2 A, 250 VAC (General Use) 80°C
G6B-2114P(-FD)(-1)-US
G6B-2214P(-FD)(-1)-US
G6B-2014P(-FD)-US
G6B-2114C(-FD)-US
G6B-2214C(-FD)-US
G6B-2014C(-FD)-US
CSA Certified:
6,000
1,000
30,000
8 A, 30 VDC (Resistive) 80°C
2 A, 30 VDC (Resistive) 80°C
5 A, 250 VAC (General Use) 80°C
2
Number of test
operations
6,000
3 to 24
VDC
5 A, 30 VDC (Resistive) 80°C
(File No. LR31928)
Model
Contact
Coil ratings
form
Contact ratings
5 A, 250 VAC (General Use) 80°C
G6B-1114P(-FD)(-1)-US
G6B-1114C(-FD)-US
1
3 to 24
VDC
G6B-1174P(-FD)(-1)-US
G6B-1174C(-FD)-US
1
3 to 24
VDC
G6B-2114P(-FD)(-1)-US
G6B-2214P(-FD)(-1)-US
G6B-2014P(-FD)-US
G6B-2114C(-FD)-US
G6B-2214C(-FD)-US
G6B-2014C(-FD)-US
2
3 to 24
VDC
G
6
B
6,000
1/6HP, 250 VAC 80°C
1,000
360 W, 120 VAC tungsten 80°C
6,000
8 A, 277 VAC (General Use) 80°C
30,000
8 A, 30 VDC (Resistive) 80°C
5 A, 250 VAC (General Use) 80°C
6,000
5 A, 30 VDC (Resistive) 80°C
EN/IEC, TÜV Certified:
Model
5 A, 30 VDC (Resistive) 80°C
Number of test
operations
(Registration No. R50158246)
Contact
Coil ratings
form
Contact ratings
Number of test
operations
5 A, 250 VAC (cosφ = 1) at 70°C
G6B-1114P(-1)-US
G6B-1114C-US
1
5, 6, 12, 24
VDC
2 A, 250 VAC(cosφ = 0.4) at 70°C
5 A, 30 VDC (L/R = 0 ms) at 70°C
8 A, 250 VAC (cosφ = 1) at 70°C
G6B-1174P(-1)-US
G6B-1174C-US
1
5, 6, 12, 24
VDC
2 A, 250 VAC (cosφ = 0.4) at 70°C
8 A, 30 VDC (L/R = 0 ms) at 70°C
G6B-2114P(-1)-US
G6B-2214P(-1)-US
G6B-2014P-US
G6B-2114C-US
G6B-2214C-US
G6B-2014C-US
2
G6B-1114P-FD(-1)-US
G6B-1114C-FD-US
1
5, 6, 12, 24
VDC
G6B-1174P-FD(-1)-US
G6B-1174C-FD-US
1
5, 6, 12, 24
VDC
20,000
5 A, 250 VAC (cosφ = 1) at 70°C
5, 6, 12, 24
VDC
1.5 A, 250 VAC (cosφ = 0.4) at 70°C
5 A, 30 VDC (L/R = 0 ms) at 70°C
3 A, 250 VAC (cosφ = 1) at 70°C
3 A, 30 VDC (L/R = 0 ms) at 70°C
5 A, 250 VAC (cosφ = 1) at 70°C
2 A, 250 VAC (cosφ = 0.4) at 70°C
5 A, 30 VDC (L/R = 0 ms) at 70°C
G6B-2114P-FD(-1)-US
G6B-2214P-FD(-1)-US
G6B-2014P-FD-US
G6B-2114C-FD-US
G6B-2214C-FD-US
G6B-2014C-FD-US
10,000
1.5 A, 250 VAC (cosφ = 0.4) at 70°C
2
5, 6, 12, 24
VDC
3 A, 30 VDC (L/R = 0 ms) at 70°C
11
G6B
PCB Power Relay
■Precautions
● Please refer to “PCB Relays Common Precautions” for correct use.
Correct Use
● Mounting
• When installing more than two Relays
side by side on a PCB, keep the gaps
as shown below.
It may cause a malfunction if heat is
not dissipated smoothly from the
Relay.
● Inhibit Circuit of the
G6B-1177P(-FD)-ND-US Model
• Do not use under conditions in which a
surge is included in the power supply,
such as when an inductive load is
connected in parallel to the coil. Doing
so will cause damage to the installed
(or built-in) coil surge absorbing diode.
Pitch:
2.54 mm × 2 min.
between terminals
Inductive
load
L
G6B
Coil
● Other precautions
• The P6B model has a flux-resistant
construction. Do not wash it down with
water.
• Perform wiring of No.1 and No. 2 of
the X terminal as COM for doublewinding latching as shown below. The
operation stability improves by doing
this.
Coil surge
absorption
diode
Pitch: 2.54 mm × 2 min.
between terminals
• No specified mounting direction.
● Mounting Height of Sockets and
Precautions
G
6
B
*17 mm max.
7 mm max.
* 19.5 mm max. for
G6B-1174P-FD-US,
G6B-1174P-US models
and 22 mm max. for
G6B-1177P-FD-ND-US,
G6B-1177P-ND-US models.
• Hold-down clips (for mounting and
removal) are also available.(For P6BC2 model) However, it is not suitable
for G6B-1174P and G6B-1177P
models.
• Removal tool is also available.
(For P6B-Y1 model) However, it is not
suitable for G6B-1177P model.
● Using SPDT contact of the
SPST-NO+SPST-NC Relay
• Do not construct a circuit so that
overcurrent and burning occur if the
NO, NC and SPDT contacts are
short-circuited with the
SPST-NO+SPST-NC Relay.Arcing
may generate short-circuiting between
contacts if there is short-circuiting
because of conversion to the MBB
contact caused by asynchronous
operation of the NO and NC contacts,
the interval between the NO and NC
contacts is small, or a large current is
left open.
6
5
S
R
1
2
COM
• Check carefully the coil polarity (+ and -)
of the Relay G6B-1177P(-FD)-ND-US.
Do not reverse the polarity when
connecting. Otherwise the built-in coil
surge absorption diode may be
damaged.
• This Relay is a Power Relay which is
suitable for power load switching. Do
not use the G6B for signal purposes
such as micro load switching under 10
mA.
• Application examples provided in this document are for reference only. In actual applications, confirm equipment functions and safety before using the product.
• Consult your OMRON representative before using the product under conditions which are not described in the manual or applying the product to nuclear control systems, railroad
systems, aviation systems, vehicles, combustion systems, medical equipment, amusement machines, safety equipment, and other systems or equipment that may have a serious
influence on lives and property if used improperly. Make sure that the ratings and performance characteristics of the product provide a margin of safety for the system or
equipment, and be sure to provide the system or equipment with double safety mechanisms.
Note: Do not use this document to operate the Unit.
OMRON Corporation
Electronic and Mechanical Components Company
12
Contact: www.omron.com/ecb
Cat. No. K021-E1-16
0118(0207)(O)