0
登录后你可以
  • 下载海量资料
  • 学习在线课程
  • 观看技术视频
  • 写文章/发帖/加入社区
创作中心
发布
  • 发文章

  • 发资料

  • 发帖

  • 提问

  • 发视频

创作活动
G6D-1A-DC5

G6D-1A-DC5

  • 厂商:

    OMRON(欧姆龙)

  • 封装:

    -

  • 描述:

    General Purpose Relay SPST-NO (1 Form A) 5VDC Coil Through Hole

  • 数据手册
  • 价格&库存
G6D-1A-DC5 数据手册
Power PCB Relay G6D Reduced board space ideal for highdensity mounting (45% smaller than the surface area of G6B) ■ Slim package: measures 6.5 W x 17.5 L x 12.5 H mm (0.26 x 0.69 x 0.49 in) ■ Switches loads up to 5 A, 250 VAC/ 30 VDC ■ Fully sealed construction allows automatic soldering and cleaning ■ Long service life: up to 300,000 operations with a 2 A, 250 VAC/30 VDC load ■ Rated for D150 pilot duty by UL, CSA ■ Optional mounting socket simplifies relay installation and servicing of finished equipment ■ Ordering Information To Order: Select the part number and add the desired coil voltage rating, (e.g., G6D-1A-DC12). Type Standard Contact form SPST-NO Terminal PCB Construction Fully sealed Part number G6D-1A ■ ACCESSORIES Connecting Socket Description PCB mount socket for G6D relay Part number P6D-04P Specifications ■ CONTACT DATA Load Rated load Contact material Carry current Max. operating voltage Max. operating current Max. switching capacity Min. permissible load Resistive load (p.f. = 1) 5 A at 250 VAC, 30 VDC Ag alloy 5A 250 VAC, 30 VDC 5A 1,250 VA, 150 W 10 mA at 5 VDC Inductive load (p.f. = 0.40, L/R = 7 ms) 2 A at 250 VAC, 30 VDC 500 VA, 60 W G6D G6D ■ COIL DATA Rated voltage (VDC) Rated current (mA) Coil resistance (Ω) Pick-up voltage 5 12 24 40 16.7 8.3 125 720 2,880 70% max. Dropout voltage Maximum voltage Power consumption (mW) 10% min. 130% at 70°C (158°F) Approx. 200 % of rated voltage Note: 1. The rated current and coil resistance are measured at a coil temperature of 23°C (73°F) with a tolerance of ±10%. 2. Operating characteristics are measured at a coil temperature of 23°C (73°F). 3. The pick-up voltage is 75% or less of rated voltage if the relay is mounted upside down. ■ CHARACTERISTICS Contact resistance Operate time Release time Bounce time Operating frequency Insulation resistance Dielectric strength Operate Mechanical Electrical Surge withstand voltage Vibration Mechanical durability Malfunction durability Shock Mechanical durability Malfunction durability Ambient temperature Operating Humidity Life expectancy Mechanical Electrical Weight 100 mΩ max. 10 ms max. (mean value: approx. 4.30 ms) 10 ms max. (mean value: approx. 5.50 ms) Mean value: approx. 1.20 ms 18,000 operations/hour 1,800 operations/hour (under rated load) 1,000 MΩ min. (at 500 VDC) 3,000 VAC, 50/60 Hz for 1 minute between coil and contacts 750 VAC, 50/60 Hz for 1 minute between contacts of the same polarity 6,000 V, 1.20 x 50 µs between coil and contacts 10 to 55 Hz, 1.50 mm (0.06 in) double amplitude for 2 hours 10 to 55 Hz, 1.50 mm (0.06 in) double amplitude for 5 minutes 1,000 m/s2 (approx. 100 G) 100 m/s2 (approx. 10 G) -25° to 70°C (-13° to 158°F) 45% to 85% RH 20 million operations min. (at operating frequency of 18,000 operations/hour) See “Characteristic Data” Approx. 3 g (0.10 oz) Note: Data shown are of initial value. ■ CHARACTERISTIC DATA Ambient temperature vs. maximum voltage Maximum voltage (%) Switching current (A) Switching voltage (V) 2 Life expectancy Life expectancy (x103 operations) Maximum switching capacity Switching current (A) Ambient temperature (°C) G6D G6D Dimensions Unit: mm (inch) ■ RELAYS G6D-1A Terminal arrangement/ Internal connections (Bottom view) Mounting holes (Bottom view) Tolerance: ± 0.1 (0.04) ■ SOCKET P6D-04P Mounting holes (Bottom view) Tolerance: ± 0.1 (0.04) 3 G6D G6D ■ APPROVALS UL (File No. E41515)/CSA (File No. LR31928) Type G6D-1A Contact form SPST-NO Coil ratings 5 to 24 VDC Contact ratings 5 A, 250 VAC (Resistive) 5 A, 30 VDC (Resistive) 1/10 HP, 120 VAC D150 Pilot Duty Note: 1. The rated values approved by each of the safety standards (e.g., UL, CSA, TUV) may be different from the performance characteristics individually defined in this catalog. 2. In the interest of product improvement, specifications are subject to change. Precautions ■ SPACING BETWEEN RELAYS ■ SOCKET MOUNTING More than two relays can be closely mounted right side up as shown in the illustration below. When mounting the relay, insert it into the socket as vertically as possible so that the relay terminals contact securely with the contact pins on the socket. The P6D-04P socket is flux-resistant. Do not wash the socket with water. Remove the relay from the socket before soldering the socket to a PC board. Mounting height More than two relays can be closely mounted upside down as shown in the illustration below. Note: The space between each relay required for heat radiation may vary with operating conditions. NOTE: DIMENSIONS ARE SHOWN IN MILLIMETERS. To convert millimeters to inches divide by 25.4. OMRON ELECTRONICS, INC. OMRON CANADA, INC. One East Commerce Drive Schaumburg, IL 60173 885 Milner Avenue Scarborough, Ontario M1B 5V8 1-800-55-OMRON 416-286-6465 Cat. No. GC RLY7 4 01/00 Specifications subject to change without notice. Printed in the U.S.A.
G6D-1A-DC5 价格&库存

很抱歉,暂时无法提供与“G6D-1A-DC5”相匹配的价格&库存,您可以联系我们找货

免费人工找货