G6D1AASI5DC

G6D1AASI5DC

  • 厂商:

    OMRON(欧姆龙)

  • 封装:

    -

  • 描述:

    G6D1AASI5DC

  • 数据手册
  • 价格&库存
G6D1AASI5DC 数据手册
G6D PCB Power Relay Slim, Miniature Relay, Capable of Relaying Programmable Controller and Temperature Controller Outputs • Reduced board space, ideal for high-density mounting (45%. (6.5 mm (W) × 17.5 mm (L) × 12.5 mm (H)) • Small, yet switches 5 A at 250 VAC/30 VDC. • Allows 300,000 operations with a 2A load at 250 VAC or 30 VDC. RoHS Compliant ■Model Number Legend ■Application Examples G6D- @ @- @- @ —— — — • Ideal for output applications of control equipments. 1 2 3 4 1. Number of Poles 1: 1-pole 3. Contact Material ASI: Silver alloy (cadmium-free) 2. Contact Form A: SPST-NO (1a) ■Characteristics 4. Contact surface AP: Au plated ■Ordering Information Enclosure rating Contact form Terminal shape Model Rated coil voltage Minimun packing unit 5 VDC 12 VDC 24 VDC 12 VDC 24 VDC 25 pcs/tube G6D-1A-ASI Fully sealed SPST-NO (1a) PCB terminals G6D-1A-ASI-AP Note. When ordering, add the rated coil voltage to the model number. Example: G6D-1A-ASI DC5 Rated coil voltage However, the notation of the coil voltage on the product case as well as on the packing will be marked as @@ VDC. ●Connecting Socket Applicable relay G6D-1A-ASI Model P6D-04P Minimun packing unit 25 pcs ■Ratings ●Coil Item Rated voltage 5 VDC 12 VDC 24 VDC Rated current (mA) Coil resistance (Ω) 40 16.7 8.3 125 720 2,880 Must operate Must release Max. voltage voltage voltage (V) (V) (V) % of rated voltage 70% max.* 10% min. 160% (at 23 C) Power consumption (mW) Approx. 200 Note 1. The rated current and coil resistance are measured at a coil temperature of 23°C with a tolerance of ±10%. Note 2. The operating characteristics are measured at a coil temperature of 23°C. Note 3. The “Max. voltage” is the maximum voltage that can be applied to the relay coil. * The must operate voltage is 75% or less of the rated voltage if the relay is mounted upside down. ●Contacts Item Contact Type Load Contact material Rated load Rated carry current Max. switching voltage Max. switching current G 6 D Resistive load Single Ag-Alloy (Cd free) (Ag-alloy (Cd free) and Au plated)* 5 A at 250 VAC 5 A at 30 VDC 5A 250 VAC, 30 VDC 5A * The content indicated in parentheses ( ) are for the G6D-1A-ASI-AP Contact resistance *1 Operate time Release time Insulation resistance *2 Between coil and contacts Dielectric Between strength contacts of the same polarity Impulse withstand voltage (between coil and contacts) 100 mΩ max. 10 ms max. 5 ms max. 1,000 MΩ min. 3,000 VAC, 50/60 Hz for 1 min 750 VAC, 50/60 Hz for 1 min 6 kV (1.2 x 50 μs) 10 to 55 to 10 Hz, 0.75 mm single amplitude (1.5 mm double amplitude) Vibration resistance 10 to 55 to 10 Hz, 0.75 mm Malfunction single amplitude (1.5 mm double amplitude) Destruction 1,000 m/s2 Shock resistance Malfunction 100 m/s2 20,000,000 operations min. Mechanical (at 18,000 operations/hr) 70,000 operations min. (5 A at 250 VAC, resistive load) 70,000 operations min. (5 A at 30 VDC, resistive Durability load) Electrical 300,000 operations min. (2 A at 250 VAC, resistive load) 300,000 operations min. (2 A at 30 VDC, resistive load) (at 1,800 operations/hr) Failure rate (P level) 10 mA at 5 VDC (reference value *3) (1 mA at 5 VDC) *4 Ambient operating -25 C to 70 C (with no icing temperature or condensation) Ambient operating humidity 5% to 85% Weight Approx. 3 g Destruction Note. The data given above are initial values. *1. Measurement conditions: 5 VDC, 1 A, voltage drop method. *2. Measurement conditions: The insulation resistance was measured with a 500 VDC megohmmeter at the same locations as the dielectric strength was measured. *3. This value was measured at a switching frequency of 120 operations/min. *4. The values indicated in parentheses ( ) are for the G6D-1A-ASI-AP. 1 G6D PCB Power Relay ■Engineering Data ●Durability 30 10 AC resistive load 5 3 ●Ambient Temperature vs. Maximum Coil Voltage 500 Maximum coil voltage (%) 50 Durability (x104 operations) Switching current (A) ●Maximum Switching Capacity 300 100 250 VAC/30 VDC resistive load 50 30 200 180 160 140 DC resistive load 1 120 AC inductive load cosφ=0.4 DC inductive load 0.5 10 100 5 250 VAC/30 VDC inductive load (cosφ=0.4/ L/R=7 ms) 3 0.3 80 0.1 0 3 5 10 30 100 0 250 500 1,000 1 2 3 4 5 6 7 8 9 60 10 0 23 30 40 50 Switching current (A) Switching voltage (V) 60 70 80 90 Ambient temperature (°C) Note. The maximum coil voltage is the maximum voltage that can be applied to the relay coil. G 6 D Must operate and must release voltage (ratio of rated voltage) (%) ●Ambient Temperature vs. Must Operate and Must Release Voltages G6D-1A-ASI (-AP) 100 ●Shock Malfunction G6D-1A-ASI (-AP) Y Sample: G6D-1A-ASI Number of Relays: 5 pcs Must Operating voltage Must Recovery voltage 80 600 X Z 400 max. 200 X 60 1,000 800 min. 206 40 Z' max. X min. 20 X' Shock direction X X' De-energized Y 0 -40 Z Z' Unit: m/s2 Energized Y' Y' -20 0 20 40 60 80 Coil terminals Sample: G6D-1A-ASI 24 VDC Number of Relays: 5 pcs Test conditions: Impose a shock in the ±X, ±Y, and ±Z directions three times each with the Relay energized to check the shock values that cause the Relay to malfunction. Ambient temperature (°C) ■Dimensions PCB Mounting Holes (Bottom View) G6D-1A-ASI (-AP) 0.5 Terminal Arrangement/ Internal Connections (Bottom View) 6.5 max. (6.4)* 17.5 max. (17.3)* 2.54 Four, 1.1-dia. (0.71) 12.5 max. (12.4)* 5.08 3.5 0.5 2.54 0.8 7.62 5.08 (1.13) (No coil polarity) 5.08 10.16 Note: Orientation marks are indicated as follows: * Average value Socket P6D-04P 13 0.3 5.08 5 1 2.54 PCB Mounting Holes (Bottom View) 19.7 max. (19.5)* 6.9 max. (6.7)* 2.54 Four, 1.1-dia. (0.86) 10.8 6±0.1 2.54 5.08 3.6 0.3 0.65 2.54 7.62 5.08 * Average value 2 (2.18) 10.16 5.08 7 G6D PCB Power Relay ■Approved Standards ●The rated values approved by each of the safety standards may be different from the performance characteristics individually defined in this datasheet. UL Recognized (File No. E41515) Model Number of poles Coil ratings G6D-1A-ASI (-AP) 1 5 to 24 VDC CSA Certified Contact ratings Number of test operations 5 A, 250 VAC 40°C 5 A, 30 VDC 40°C 6,000 (File No. LR31928) Model Number of poles Coil ratings G6D-1A-ASI (-AP) 1 5 to 24 VDC EN/TÜV Certified Contact ratings Number of test operations 5 A, 250 VAC (Resistive) 40°C 5 A, 30 VDC (Resistive) 40°C 6,000 (Registration No. R50167084) Model Number of poles Coil ratings G6D-1A-ASI (-AP) 1 5, 12, 24 VDC Contact ratings Number of test operations 5 A, 250 VAC (cosφ=1.0) 70°C 5 A, 30 VDC (0 ms) 40°C 70,000 ■Precautions ●Please refer to “PCB Relays Common Precautions” for correct use. Correct Use ●Mounting • More than two relays can be closely mounted right side up as shown in the following illustration. Upper side 6.5 mm Current flow: 5 A max. G 6 D ●Socket Mounting Height 18.5 mm max. Upper side 1.12 mm 7.62 mm in the upside-down direction Current flow: 2 A max. Note. The space between each relay required for heat radiation may vary with operating conditions. Contact your OMRON representative for details. ●Mounting to a P6D • The P6D is flux-resistive. Do not wash the P6D with water. • Dismount the relay from the socket before soldering the socket to a PCB. • Use Surge Killer Diode when switching a DC inductive load in micro load (about 10 to 100 mA). (Carbon deposition may decrease the contact reliability.) 3 G6D PCB Power Relay G 6 D · Application examples provided in this document are for reference only. In actual applications, confirm equipment functions and safety before using the product. · Consult your OMRON representative before using the product under conditions which are not described in the manual or applying the product to nuclear control systems, railroad systems, aviation systems, vehicles, combustion systems, medical equipment, amusement machines, safety equipment, and other systems or equipment that may have a serious influence on lives and property if used improperly. Make sure that the ratings and performance characteristics of the product provide a margin of safety for the system or equipment, and be sure to provide the system or equipment with double safety mechanisms. Note: Do not use this document to operate the Unit. OMRON Corporation Electronic and Mechanical Components Company 4 Contact: www.omron.com/ecb Cat. No. K127-E1-04 0316(0207)(O)
G6D1AASI5DC 价格&库存

很抱歉,暂时无法提供与“G6D1AASI5DC”相匹配的价格&库存,您可以联系我们找货

免费人工找货