G6RN-1-DC5

G6RN-1-DC5

  • 厂商:

    OMRON(欧姆龙)

  • 封装:

    -

  • 描述:

    G6RN-1-DC5

  • 数据手册
  • 价格&库存
G6RN-1-DC5 数据手册
G6RN PCB Power Relay Miniature Power Relay for Switching 8 A • Low-profile height of 15 mm (approx. 60% the height of the Omron G2R model). • Capable of switching with 8 A at 250 VAC despite its small size. • High sensitivity with 220mW power consumption. • Offers high insulation with insulation distance of 8 mm and impulse withstand voltage of 10kV between coil and contacts. • Satisfies ambient operating temperature requirement of 85°C. • Standard model conforms to VDE standards. RoHS Compliant ■Model Number Legend ■Application Examples G 6 R N -@ @ —— • Control equipments 1 2 1. Number of Poles 1: 1-pole 2. Contact Form None: SPDT (1c) A: SPST-NO (1a) ■Ordering Information Classification Enclosure rating Standard Fully sealed Contact form SPST-NO (1a) SPDT (1c) Terminal shape PCB terminals Model G6RN-1A G6RN-1 Rated coil voltage 5, 6, 12 VDC 24 VDC 5, 6, 12 VDC 24 VDC Minimun packing unit 20 pcs/tube Note. When ordering, add the rated coil voltage to the model number. Example: G6RN-1A DC5 Rated coil voltage However, the notation of the coil voltage on the product case will be marked as @@VDC. ●Coil Rated voltage 5 VDC 6 VDC 12 VDC 24 VDC Contact resistance *1 Operate time Release time Insulation resistance *2 Between coil and contacts Dielectric Between strength contacts of the same polarity Impulse withstand voltage (between coil and contacts) Between Insulation coil and distance contacts 100 mΩ max. 15 ms max. 5 ms max. 1,000 MΩ min. 4,000 VAC, 50/60 Hz for 1 min 1,000 VAC, 50/60 Hz for 1 min 10,000 V (1.2 x 50 μs) Clearance: 8 mm, Creepage: 8 mm 10 to 55 to 10 Hz, 0.75 mm single amplitude (1.5 mm double amplitude) Vibration 10 to 55 to 10 Hz resistance NO: 0.75 mm single amplitude Malfunction (1.5 mm double amplitude) NC: 0.4 mm single amplitude (0.8 mm double amplitude) Destruction 1,000 m/s2 Shock NO: 100 m/s2 resistance Malfunction NC:: 50 m/s2 10,000,000 operations min. Mechanical (at 36,000 operations/hr) 50,000 operations min. (8 A at 250 VAC, resistive load) Durability 50,000 operations min. Electrical *3 (5 A at 30 VDC, resistive load) (at 360 operations/hr under rated load) Failure rate (P level) 10 mA at 5 VDC (reference value) *4 Ambient operating -40°C to 85°C (with no icing or temperature condensation) Ambient operating 5% to 85% humidity Weight Approx. 9 g Destruction ■Ratings Item G 6 R N ■Characteristics Rated current (mA) Coil resistance (Ω) 43.9 36.6 18.3 9.2 114 164 655 2,620 Must operate Must release Max. voltage voltage voltage (V) (V) (V) % of rated voltage 70% max. 10% min. 150% (at 23°C) Power consumption (mW) Approx. 220 Note 1. The rated current and coil resistance are measured at a coil temperature of 23°C with a tolerance of ±10%. *2. The operating characteristics are measured at a coil temperature of 23°C. *3. The “Max. voltage” is the maximum voltage that can be applied to the relay coil. ●Contacts Load Resistive load Item Contact type Single Ag-Alloy + gold plating Contact material (Cd free) 8 A at 250 VAC Rated load 5 A at 30 VDC Rated carry 8A current Max. switching 250 VAC, 30 VDC voltage Max. switching 8A current Note. The data given above are initial values. *1. Measurement conditions: 5 VDC, 1 A, voltage drop method. *2. Measurement conditions: The insulation resistance was measured with a 500 VDC megohmmeter at the same locations as the dielectric strength was measured. *3. Test conditions: With diode *4. This value was measured at a switching frequency of 120 operations/min. 1 G6RN PCB Power Relay ■Engineering Data 50 30 DC resistive load AC resistive load 10 8 5 3 ●Ambient Temperature vs. Maximum Coil Voltage 100 Maximum coil voltage (%) ●Durability Durability (x 104 operations) Switching current (A) ●Maximum Switching Capacity 250 VAC resistive load 30 VDC resistive load 50 30 10 200 180 160 150 140 130 120 1 5 0.5 3 110 100 0.3 80 0.1 0 3 5 10 30 50 100 1 250 500 0 2 4 6 Switching Voltage (V) Operate/Release voltage (percentage of rated value) (%) G 6 R N 80 Y 1,000 X 1,000 Z 1,000 60 contact B 88.2 40 -20 0 20 40 60 80 60 70 Sample: G6RN-1 24 VDC Number of Relays: 5 pcs Test conditions: The value at which malfunction occurred was measured after applying shock to the test piece 3 times each in 6 directions along 3 axes. Standard value: 100m/s2 at contact A, 50m/s2 at contact B 1,000 X' 1,000 Z' max. X min. 1,000 Y' 0 -40 50 Unit: m/s2 Y Shock direction X X' Z Z' 100 Y' Ambient Temperature (°C) ■Dimensions PCB Mounting Holes (Bottom View) G6RN-1 Terminal Arrangement/ Internal Connections (Bottom View) 10±0.5 28.5±0.5 Five, 1.3-dia. holes (1.19) 15±0.5 3.5 0.5 19 (1.19) 19±0.1 G6RN-1A PCB Mounting Holes (Bottom View) 4 3 (No coil polarity) Four, 1.3-dia. holes (1.19) 3.5 5.1 1 2 7.62±0.1 0.5 (1.19) 7.62 19±0.1 (1.6) 2 2 Terminal Arrangement/ Internal Connections (Bottom View) 10±0.5 15±0.5 19 5 (1.5) 3.2±0.1 3.2±0.1 (1.6) 3.2 28.5±0.5 1 7.62±0.1 7.62 3.2 80 90 100 Note. The maximum coil voltage refers to the maximum value in a varying range of operating power voltage, not a continuous voltage. contact A max. X min. 20 40 Ambient Temperature (°C) ●Shock Malfunction G6RN-1 Must operate voltage Must release voltage Sample: G6RN-1 12 VDC Number of Relays: 5 pcs 0 -40 20 23 30 10 Switching Current (A) ●Ambient Temperature vs. Maximum Coil Voltage 100 8 5.1±0.1 (2.8) 5 (No coil polarity) 3 G6RN PCB Power Relay ■Approved Standards ●The rated values approved by each of the safety standards may be different from the performance characteristics individually defined in this catalog. UL Recognized (File No. E41515) CSA Certified (File No. 31928) Model Number of poles Coil ratings 1 5 to 24 VDC G6RN-1 EN/TÜV Certified Model Number of test operations 8 A, 250 VAC 85°C 8 A, 30 VDC 85°C 6,000 (Certificate No. 6135) Number of poles Coil ratings 1 5, 6, 12, 24 VDC G6RN-1 G6RN-1A Contact ratings Contact ratings Approved switching operations 8 A, 250 VAC (Resistive) 85°C 10,000 Creepage distance 8 mm Clearance distance 8 mm Insulation material group IIIa Rated Insulation voltage 250 V Pollution degree 2 Rated voltage system 250 V Overvoltage category III Tracking Index of relay base PTI 250 V min. (housing parts) Flammability class according to UL94 V-0 Ball pressure test (IEC 60695-10-2) 160°C G 6 R N ■Precautions ●Please refer to “PCB Relays Common Precautions” for correct use. • Application examples provided in this document are for reference only. In actual applications, confirm equipment functions and safety before using the product. • Consult your OMRON representative before using the product under conditions which are not described in the manual or applying the product to nuclear control systems, railroad systems, aviation systems, vehicles, combustion systems, medical equipment, amusement machines, safety equipment, and other systems or equipment that may have a serious influence on lives and property if used improperly. Make sure that the ratings and performance characteristics of the product provide a margin of safety for the system or equipment, and be sure to provide the system or equipment with double safety mechanisms. Note: Do not use this document to operate the Unit. OMRON Corporation Electronic and Mechanical Components Company Contact: www.omron.com/ecb Cat. No. J182-E1-04 1116(0207)(O) 3
G6RN-1-DC5 价格&库存

很抱歉,暂时无法提供与“G6RN-1-DC5”相匹配的价格&库存,您可以联系我们找货

免费人工找货