G70V-SOC16P-1-C4

G70V-SOC16P-1-C4

  • 厂商:

    OMRON(欧姆龙)

  • 封装:

  • 描述:

    RLYTERMBLK OUTPT PNP COM 4TERM

  • 数据手册
  • 价格&库存
G70V-SOC16P-1-C4 数据手册
New Product I/O Relay Terminal G70V I/O Relay Terminals with 16 Points and Push-In Plus terminal blocks to Downsize Control Panels and Save Labor • I/O Relay Terminals with 16 points to mount G2RV Slim I/O Relays. • Push-In Plus terminal blocks are used to save wiring work in comparison with traditional screw terminals. (Wiring time is reduced by 60%* in comparison with traditional screw terminals.) • Work is reduced ever further with one-step cable connection For the most recent information on models that have been to the PLC. certified for safety standards, refer to your OMRON website. • Diode provided for coil surge absorption. • Operation indicators for immediate recognition of I/O signal status. • Accepts G3RV Slim I/O SSRs. • Greatly reduce wiring work and maximize space efficiency with new models that provide internal connections between I/O terminals. (input models: 16 point/common, output models: 4 points/common) • DIN Track or screw mounting. * According to OMRON actual measurement data from November 2015. Refer to Safety Precautions on page 17. Model Number Legend G70V - @ @ @ 16 P - @- @ (1) (2) (3) (4) (5) (6) (7) (1) Mountable Relays S: Relays Z: Sockets (2) Input/Output Classification I: For input O: For output (3) I/O Specification C: Contacts (Applicable when (2) is O (for output) (relay output).) D: DC (Applicable when (2) is I (for input) (coil for input).) M: AC/DC (Applicable when (1) is Z (Sockets).) (4) Number of I/O Points 16: 16 points (5) Terminal Type P: Push-In Plus terminal blocks (6) Common Line on Connector Side Blank: NPN 1: PNP (7) Common Line on Terminal Block Side Blank: No internal connections C4: Every 4 points internally connected at terminal block bottom row C4-D: Every 4 points internally connected at terminal block middle row C16: 16 points internally connected (For Input NPN) PLC (For Input PNP) G70V (+) PLC G70V )+( − Common )−( (−) (For Output NPN) + Common (For Output PNP) PLC G70V PLC (+) NPN transistor X + (−) G70V (+) − X Common PNP transistor Common X X (−) 1 G70V Ordering Information I/O Relay Terminals Terminals Classification Common Line Terminal Block Side Points No internal connections Input *1 16 points internally connected Push-In Plus terminal blocks 16 No internal connections Output *2 Every 4 points internally connected at terminal block bottom row Connector Side NPN (– common) PNP (+ common) NPN (– common) PNP (+ common) NPN (+ common) PNP (– common) NPN (+ common) PNP (– common) Rated voltage Model 24 VDC G70V-SID16P G70V-SID16P-1 G70V-SID16P-C16 G70V-SID16P-1-C16 G70V-SOC16P G70V-SOC16P-1 G70V-SOC16P-C4 G70V-SOC16P-1-C4 *1. Mountable Relays: G2RV-1-S-AP-G DC21V. *2. Mountable Relays: G2RV-1-S-G DC21V. I/O Terminal Sockets Applicable I/O Relay Terminal Common Line Classification G70V-SID16P G70V-SID16P-1 G70V-SID16P-C16 G70V-SID16P-1-C16 G70V-SOC16P G70V-SOC16P-1 G70V-SOC16P-C4 G70V-SOC16P-1-C4 Terminal Block Side Connector Side No internal connections Input 16 points internally connected No internal connections Every 4 points internally connected at terminal block bottom row Output Every 4 points internally connected at terminal block middle row --- * NPN (– common) PNP (+ common) NPN (– common) PNP (+ common) NPN (+ common) PNP (– common) NPN (+ common) PNP (– common) NPN (+ common) PNP (– common) Model G70V-ZID16P G70V-ZID16P-1 G70V-ZID16P-C16 G70V-ZID16P-1-C16 G70V-ZOM16P G70V-ZOM16P-1 G70V-ZOM16P-C4 G70V-ZOM16P-1-C4 G70V-ZOM16P-C4-D G70V-ZOM16P-1-C4-D Note: Relays are not mounted to the G70V-ZID/ZOM16P(-1) I/O Terminal Sockets. Combine the I/O Terminal Sockets with Slim I/O Relays or Slim I/O SSRs. * The G70V-ZOM16P(-1)-C4-D does not come with SSRs. Use Slim I/O SSRs (for DC: G3RV-D03SL). Options (Order Separately) Mountable Relays Applicable I/O Relay Terminal Classification G70V-SID16P(-1)(-C16) G70V-ZID16P(-1)(-C16) Type Slim I/O Relays *1 Input Slim I/O Relays G70V-SOC16P(-1)(-C4) G70V-ZOM16P(-1)(-C4) Output G70V-ZOM16P(-1)-C4-D *3 Output Model Slim I/O SSRs Slim I/O SSRs G2RV-1-S-AP-G DC21 No Latching Lever *2 Latching Lever Zero cross function For AC No zero cross function For DC For DC G2RV-1-S-G DC21 G2RV-1-SI-G DC21 G3RV-202S DC24 G3RV-202SL DC24 G3RV-D03SL DC24 G3RV-D03SL DC24 Note: To use Slim I/O SSRs, either remove the Slim I/O Relays to mount them or order a I/O Terminal Sockets and I/O SSRs separately and combine them. *1. G2RV-1-S-AP-G Slim I/O Relays are mounted to G70V-SID16P(-1)(-C16) I/O Relay Terminals as a standard feature. *2. G2RV-1-S-G Slim I/O Relays are mounted to G70V-SOC16P(-1)(-C4) I/O Relay Terminals as a standard feature. *3. The G70V-ZOM16P(-1)-C4-D does not come with SSRs. Use Slim I/O SSRs (for DC: G3RV-D03SL). When ordering, designate the rated voltage. Cables for I/O Relay Terminals XW2Z-R • Cable with Loose Wire and Crimp Terminals: • Cable with Loose Wires: • Cable with connectors • Fujitsu connectors (1:1): (1:2): (1:3): XW2Z-RY@C XW2Z-RA@C XW2Z-R@C XW2Z-RI@C-@ XW2Z-RO@C-@ XW2Z-R@C-@-@ • MIL connectors (1:2): Refer to Connecting Cables on page 19 for details. Labels Appearance 2 (1:1): Model Minimum order (sheet) (quantity per sheet) XW5Z-P2.5LB2 5 (1 sheet / 72 pieces) XW2Z-RI@C XW2Z-RO@C XW2Z-RI@-@-D@ XW2Z-RM@-@-D@ XW2Z-RO@-@-D1 G70V Accessories for DIN Track Mounting Appearance Name Minimum order (quantity) Model 1m PFP-100N 0.5 m PFP-50N DIN Tracks 1 PFP-M * End Plate 10 PFP-S * Spacer * These products must be ordered in sets of 10. Option Mounting Example Mounting to DIN Track Label Enlarged view DIN Track PFP-100N (1 m) PFP-50N (50 cm) End Plate PFP-M Specifications Coil Ratings (Common to Input/Output per Relay) Item Must Must Maximum Power operate of release of rated voltage of rated consumption rated voltage voltage voltage (mW) 13.3 1575 80% max. 10% min. 110% Approx. 280 The rated current and coil resistance are measured at a coil temperature of 23°C with a tolerance of ±15% for coil resistance. The operating characteristics are measured at a coil temperature of 23°C. The value for maximum voltage is the maximum value within the allowable voltage fluctuation range for the relay coil’s operating power supply. Continuous operation at this voltage is not within product specifications. The rated current includes the current for the indicators on the I/O Relay Terminal. Rated voltage (V) 24 VDC Note: 1. 2. 3. 4. Rated current (mA) Coil resistance (Ω) Contact Ratings (G2RV-1-S-G I/O Relay) Classification Item For input Resistive load (cosφ=1) Resistive load (cosφ=1) Inductive load (cosφ=0.4 L/R=7 ms) 2.5 A at 250 VAC 2 A at 30 VDC 6 A at 250 VAC 6 A at 30 VDC Rated carry current 6 A/point, 10 A/common Max. switching voltage 250 VAC, 125 VDC Max. switching current 6 A/point, 10 A/common 1,500 VA 500 VA Maximum switching capacity --180 W 60 W Error rate (reference value) * 1 mA at 100 mVDC 10 mA at 5 VDC NO contacts: 70,000 operations min. Electrical endurance 5,000,000 operations min. NC contacts: 50,000 operations min. Mechanical endurance 5,000,000 operations min. 5,000,000 operations min. * The above values are for a switching frequency of 120 operations/min. Rated load 50 mA at 30 VAC 50 mA at 36 VDC 50 mA 30 VAC, 36 VDC 50 mA For output 3 G70V Characteristics Model Item G70V-SID16P(-1)(-C16) (Input, DC coil) SPST-NO × 16 Ag alloy + Au plating 150 mΩ max. 20 ms max. 40 ms max. 18,000 operations/h G70V-SOC16P(-1)(-C4) (output, DC coil) Contact form Contact material Contact resistance *1 Must Operate time *2 Release time *2 Max. Mechanical limit switching At rated load 1,800 operations/h (under rated load) frequency Insulation resistance 100 MΩ min. Dielectric strength Between coil and contacts: 2,500 VAC for 1 min Vibration resistance 100 m/s2 Shock resistance 100 m/s2, 3 times each in 6 directions along 3 axes Noise immunity Noise level: 1.5 kV; pulse width: 100 ns to 1 μs Ambient operating −40 to 55°C (with no icing or condensation) temperature Ambient operating humidity 35% to 85% Power supply Green LED color I/O Yellow Weight Approx. 350 g Note: The above values are initial values. *1. Measurement: 1 A at 5 VDC. *2. Ambient temperature: 23°C. SPDT × 16 Ag alloy Approx. 370 g Approved Standards The rated values for safety standard certification are not the same as individually defined performance values. Always check the specifications before use. UL standard certification (File No. E95399) Type I/O Relay Terminal I/O Terminal Sockets Model G70V-SID16P(-1) G70V-SID16P(-1)-C16 G70V-SOC16P(-1) G70V-SOC16P(-1)-C4 G70V-ZID16P(-1) G70V-ZID16P(-1)-C16 G70V-ZOM16P(-1) G70V-ZOM16P(-1)-C4 G70V-ZOM16P(-1)-C4-D Ratings Standard number Category Listed/Recognized Contact ratings 24V DC Listed 24V DC USL: UL 61010-1-12 CNL: UL 61010-2-201 250V AC / 30V DC Resistive 4A at 40°C NRAQ, NRAQ7 24V DC Recognized 250V AC / 30V DC Resistive 4A at 40°C Note: 1. USL refers to certification in the US, and CNL refers to certification in Canada. 2. cULus certification has been obtained in Canada. (CAN/CSA-C22.2 No. 61010-2-201) TÜV Rheinland certification (Certification No. R50327604) Type Model G70V-SID16P(-1) G70V-SID16P(-1)-C16 Ratings Standard number Operating coil 24V DC 0.05A L/R=0ms G70V-SOC16P(-1) I/O Relay Terminal 24V DC EN 61810-1 24V DC G70V-SOC16P(-1)-C4 G70V-ZID16P(-1) G70V-ZID16P(-1)-C16 single load: 250V AC 6A cos(phi)=1 16 loads: 250V AC 3A cos(phi)=1 16 loads: 30V DC 3A L/R=0ms 16 loads: 250V AC 5A cos(phi)=1 (Ta=+25°C) 16 loads: 30V DC 5A L/R=0ms (Ta=+25°C) 250V AC / 30V DC 16 loads: 5A (Ta=+25°C) 16 loads: 3A (Ta=+55°C) 1 load: 6A Resistive load total max. 10A common line 24V DC 0.05A L/R=0ms G70V-ZOM16P(-1) I/O Terminal Sockets Contact ratings 24V DC EN 61810-1 G70V-ZOM16P(-1)-C4 G70V-ZOM16P(-1)-C4-D 24V DC single load: 250V AC 6A cos(phi)=1 16 loads: 250V AC 3A cos(phi)=1 16 loads: 30V DC 3A L/R=0ms 16 loads: 250V AC 5A cos(phi)=1 (Ta=+25°C) 16 loads: 30V DC 5A L/R=0ms (Ta=+25°C) 250V AC / 30V DC 16 loads: 5A (Ta=+25°C) 16 loads: 3A (Ta=+55°C) 1 load: 6A Resistive load total max. 10A common line CE Marking Compliance Model G70V EMC Directive Not applicable Low Voltage Directive ❍ Machinery Directive Not applicable Note: 1. The Safety Category refers to the maximum applicable category selected when constructing control system safety components. The category does not apply to individual components. 2. Details and other information on conformity levels are issued as part of the "EU Declaration of Conformity." Please contact your OMRON representative for more information. 4 G70V Engineering Data (Reference Value) Operations (× 103) Endurance Curve (NO Contacts) G70V-SOC16P(-1)(-C4) 1000 30 VDC resistive load 250 VAC resistive load 100 30 VDC inductive load 250 VAC inductive load 10 0 2 4 6 Switched current (A) Note: These data are actual measured values that were sampled from the production line and prepared in graph format, and are for reference purposes only. A relay is manufactured by mass production, and as a basic rule must be used with allowance made for a certain amount of deviation. Load Current vs. Ambient Temperature G3RV-202S DC24 G70V-SOC16P(-1)(-C4) G3RV-D03 DC24 (A) Single Relay 6 16 points ON 5 (A) Load Current (A) Load Current (A) Load Current (A) G3RV-202SL DC24 3 4 (A) 3 Single Relay Single Relay 2 2 3 16 points ON 16 points ON 2 1 1 1 0.5 0.2 0 -40 -20 0 0 -40 20 25 40 55 60 Ambient Temperature -20 0 20 25 40 55 60 Ambient Temperature 0 -40 -20 0 20 40 55 60 Ambient Temperature Inrush Current Resistance: Non-repetitive The following graphs show the maximum inrush currents that can be withstood for non-repetitive operation. For repetitive operation, the figures should be reduced by half. G3RV-D03 DC24 Inrush current (A. Peak) Inrush current (A. Peak) G3RV-202S DC24 G3RV-202SL DC24 40 35 30 25 40 35 30 25 20 20 15 15 10 10 5 5 0 10 30 50 100 300 500 1,000 3,000 5,000 Energized time (ms) 0 10 30 50 100 300 500 1,000 3,000 5,000 Energized time (ms) 5 G70V Internal Circuits G70V-SID16P (NPN input/– common) 10 Connector Pin Configuration Top View 20 Relay No. 1 2 3 4 5 6 7 8 + − 1 11 2 12 3 13 4 14 5 15 6 16 7 17 8 18 9 19 10 20 9 10 11 12 13 14 15 16 + − Connector pin No. 1 2 3 4 5 6 7 8 11 12 13 14 15 16 17 18 9 19 X Input relays G2RV-1-S-AP-G X V V X V G G G Push-in power supply terminals X X X X X X X X X X X X X X V V V V V V V V V V V V V V V G G G G G G G G G G G G G G G Push-in I/O terminals mark Connector pin No. Note: Pin numbers are indicated for convenience. The ▲ mark can be used to determine orientation. Terminal name Description V (push-in power supply terminals) Unit power supply terminals (24 VDC) G (push-in power supply terminals) V (push-in I/O terminals) Relay-drive coil terminals (24 VDC) G (push-in I/O terminals) G70V-SID16P-1 (PNP input/+ common) Connector Pin Configuration Top View 10 20 Relay No. 1 2 3 4 5 6 7 8 − + 1 11 2 12 3 13 4 14 5 15 6 16 7 17 8 18 9 19 10 20 9 10 11 12 13 14 15 16 − + mark Connector pin No. Connector pin No. 1 2 3 4 5 6 7 8 11 12 13 14 15 16 17 18 9 19 X Input relays G2RV-1-S-AP-G X V V X V G G G Push-in power supply terminals X X X X X X X X X X X X V V V V V V V V V V V V V V V G G G G G G G G G G G G G G Terminal name G (push-in power supply terminals) V (push-in I/O terminals) G (push-in I/O terminals) 6 X G Note: Pin numbers are indicated for convenience. The ▲ mark can be used to determine orientation. V (push-in power supply terminals) X Description Unit power supply terminals (24 VDC) Relay-drive coil terminals (24 VDC) Push-in I/O terminals G70V G70V-SID16P-C16 (NPN input/– common) Connector Pin Configuration Top View 10 20 Relay No. 1 2 3 4 5 6 7 8 + − 1 11 2 12 3 13 4 14 5 15 6 16 7 17 8 18 9 19 10 20 9 10 11 12 13 14 15 16 + − Connector pin No. 1 2 3 4 5 6 7 8 11 12 13 14 15 16 17 18 9 19 X V mark Connector pin No. X V G G Push-in power supply terminals X X X X X X X X X X X X X X Input relays X G2RV-1-S-AP-G V V V V V V V V V V V V V V V V G G G G G G G G G G G G G G G G Push-in I/O terminals Note: Pin numbers are indicated for convenience. The ▲ mark can be used to determine orientation. Terminal name Description V (push-in power supply terminals) Unit power supply terminals (24 VDC) G (push-in power supply terminals) V (push-in I/O terminals) Relay-drive coil terminals (24 VDC) G (push-in I/O terminals) G70V-SID16P-1-C16 (PNP input/+ common) Connector Pin Configuration Top View 10 20 Relay No. 1 2 3 4 5 6 7 8 − + 1 11 2 12 3 13 4 14 5 15 6 16 7 17 8 18 9 19 10 20 9 10 11 12 13 14 15 16 − + Connector pin No. mark Connector pin No. 1 2 3 4 5 6 7 8 11 12 13 14 15 16 17 18 9 19 X V V G G Push-in power supply terminals X X X X X X X X X X X X X X X Input relays X G2RV-1-S-AP-G V V V V V V V V V V V V V V V V G G G G G G G G G G G G G G G G Push-in I/O terminals Note: Pin numbers are indicated for convenience. The ▲ mark can be used to determine orientation. Terminal name V (push-in power supply terminals) G (push-in power supply terminals) V (push-in I/O terminals) G (push-in I/O terminals) Description Unit power supply terminals (24 VDC) Relay-drive coil terminals (24 VDC) 7 G70V G70V-SOC16P (NPN output/+ common) Note: A controller with an NPN transistor, common output can be connected to the G70V-SOC16P. Connector Pin Configuration Top View X Output relays G2RV-1-S-G Relay No. 1 2 3 4 5 6 7 8 − + 1 11 2 12 3 13 4 14 5 15 6 16 7 17 8 18 9 19 10 20 9 10 11 12 13 14 15 16 − + Connector pin No. mark Connector pin No. 1 2 3 4 5 6 7 8 11 12 13 14 15 16 17 18 10 20 9 19 12 22 32 42 52 62 72 82 12 22 32 42 52 62 72 82 V V 14 24 34 44 54 64 74 84 14 24 34 44 54 64 74 84 G G 11 21 31 41 51 61 71 81 11 21 31 41 51 61 71 81 Note: Pin numbers are indicated for convenience. The ▲ mark can be used to determine orientation. Terminal name Description V (push-in power supply terminals) Unit power supply terminals (24 VDC) G (push-in power supply terminals) 11 to 81 (push-in I/O terminal common terminals) 12 to 82 (push-in I/O terminal NC terminals) Relay contact terminals 14 to 84 (push-in I/O terminal NO terminals) G70V-SOC16P-1 (PNP output/- common) Note: A controller with a PNP transistor, + common output can be connected to the G70V-SOC16P-1. Connector Pin Configuration Top View X Output relays G2RV-1-S-G Relay No. 1 2 3 4 5 6 7 8 − + 1 11 2 12 3 13 4 14 5 15 6 16 7 17 8 18 9 19 10 20 9 10 11 12 13 14 15 16 − + mark Connector pin No. Connector pin No. 1 2 3 4 5 6 7 8 11 12 13 14 15 16 17 18 10 20 9 19 V V G G 12 14 11 22 24 21 32 34 31 42 44 41 52 54 51 62 64 61 72 74 71 82 84 81 12 14 11 22 24 21 Note: Pin numbers are indicated for convenience. The ▲ mark can be used to determine orientation. Terminal name V (push-in power supply terminals) G (push-in power supply terminals) Description Unit power supply terminals (24 VDC) 11 to 81 (push-in I/O terminal common terminals) 12 to 82 (push-in I/O terminal NC terminals) 14 to 84 (push-in I/O terminal NO terminals) 8 Relay contact terminals 32 34 31 42 44 41 52 54 51 62 64 61 72 74 71 82 84 81 G70V G70V-SOC16P-C4 (NPN output/+ common) Note: A controller with an NPN transistor, common output can be connected to the G70V-SOC16P-C4. Connector Pin Configuration Top View X Output relays G2RV-1-S-G Relay No. 1 2 3 4 5 6 7 8 − + 1 11 2 12 3 13 4 14 5 15 6 16 7 17 8 18 9 19 10 20 9 10 11 12 13 14 15 16 − + Connector pin No. mark Connector pin No. 1 2 3 4 5 6 7 8 11 12 13 14 15 16 17 18 10 20 9 19 12 22 32 42 52 62 72 82 12 22 32 42 52 62 72 82 V V 14 24 34 44 54 64 74 84 14 24 34 44 54 64 74 84 G G 11 21 31 41 51 61 71 81 11 21 31 41 51 61 71 81 Note: Pin numbers are indicated for convenience. The ▲ mark can be used to determine orientation. Terminal name Description V (push-in power supply terminals) Unit power supply terminals (24 VDC) G (push-in power supply terminals) 11 to 81 (push-in I/O terminal common terminals) 12 to 82 (push-in I/O terminal NC terminals) Relay contact terminals 14 to 84 (push-in I/O terminal NO terminals) G70V-SOC16P-1-C4 (PNP output/- common) Note: A controller with a PNP transistor, + common output can be connected to the G70V-SOC16P-1-C4. Connector Pin Configuration Top View X Output relays G2RV-1-S-G Relay No. 1 2 3 4 5 6 7 8 − + 1 11 2 12 3 13 4 14 5 15 6 16 7 17 8 18 9 19 10 20 9 10 11 12 13 14 15 16 − + mark Connector pin No. Connector pin No. 1 2 3 4 5 6 7 8 11 12 13 14 15 16 17 18 10 20 9 19 12 22 32 42 52 62 72 82 12 22 32 42 52 62 72 82 V V 14 24 34 44 54 64 74 84 14 24 34 44 54 64 74 84 G G 11 21 31 41 51 61 71 81 11 21 31 41 51 61 71 81 Note: Pin numbers are indicated for convenience. The ▲ mark can be used to determine orientation. Terminal name V (push-in power supply terminals) G (push-in power supply terminals) Description Unit power supply terminals (24 VDC) 11 to 81 (push-in I/O terminal common terminals) 12 to 82 (push-in I/O terminal NC terminals) Relay contact terminals 14 to 84 (push-in I/O terminal NO terminals) 9 G70V G70V-ZOM16P-C4-D (NPN output/- common) Note: A controller with an NPN transistor, common output can be connected to the G70V-ZOM16P-C4-D. Connector Pin Configuration Top View X Output Relays* G3RV-D03SL (Relays sold separately.) Relay No. 1 2 3 4 5 6 7 8 − + 1 11 2 12 3 13 4 14 5 15 6 16 7 17 8 18 9 19 10 20 9 10 11 12 13 14 15 16 − + Connector pin No. mark Connector pin No. 1 2 3 4 5 6 7 8 11 12 13 14 15 16 17 18 10 20 9 19 V V G G 12 22 32 42 52 62 72 82 12 22 32 42 52 62 72 82 14 24 34 44 54 64 74 84 14 24 34 44 54 64 74 84 11 21 31 41 51 61 71 81 11 21 31 41 51 61 71 81 Note: Pin numbers are indicated for convenience. The ▲ mark can be used to determine orientation. Terminal name Description V (push-in power supply terminals) Unit power supply terminals (24 VDC) G (push-in power supply terminals) 11 to 81 (push-in I/O terminal SSR output terminal +) 12 to 82 (push-in I/O terminal Open terminal) SSR contact terminals 14 to 84 (push-in I/O terminal SSR output terminal -) * The G70V-ZOM16P-C4-D does not come with SSRs. Use Slim I/O SSRs (for DC: G3RV-D03SL). G70V-ZOM16P-1-C4-D (PNP output/- common) Note: A controller with an PNP transistor, common output can be connected to the G70V-ZOM16P-1-C4-D. Connector Pin Configuration Top View X Output Relays* G3RV-D03SL (Relays sold separately.) Relay No. 1 2 3 4 5 6 7 8 − + 1 11 2 12 3 13 4 14 5 15 6 16 7 17 8 18 9 19 10 20 9 10 11 12 13 14 15 16 − + mark Connector pin No. Connector pin No. 1 2 3 4 5 6 7 8 11 12 13 14 15 16 17 18 10 20 9 19 V V G G 12 22 32 42 52 62 72 82 12 22 32 42 52 62 72 82 14 24 34 44 54 64 74 84 14 24 34 44 54 64 74 84 11 21 31 41 51 61 71 81 11 21 31 41 51 61 71 81 Note: Pin numbers are indicated for convenience. The ▲ mark can be used to determine orientation. Terminal name V (push-in power supply terminals) G (push-in power supply terminals) Description Unit power supply terminals (24 VDC) 11 to 81 (push-in I/O terminal SSR output terminal +) 12 to 82 (push-in I/O terminal Open terminal) SSR contact terminals 14 to 84 (push-in I/O terminal SSR output terminal -) * The G70V-ZOM16P-1-C4-D does not come with SSRs. Use Slim I/O SSRs (for DC: G3RV-D03SL). 10 G70V Dimensions (Unit: mm) Main unit I/O Relay Terminals and I/O Terminal Sockets For Inputs G70V-SID16P G70V-SID16P-1 G70V-ZID16P G70V-ZID16P-1 G70V-SID16P-C16 G70V-SID16P-1-C16 G70V-ZID16P-C16 G70V-ZID16P-1-C16 143 max. 4.35 4.2-dia. hole (M4 screw) 4.35 Relay 90 max. 35.2 7.5 4.35 10.26 4.1 5 4.35 4.2-dia. hole (M4 screw) 18.3 16.7 20.2 29.9 56 max. Note: 1. Relays are not mounted to the G70V-ZID16P(-1)(-C16) I/O Terminal Sockets. The dimensions are for when Relays are not mounted. 2. Specified mounting torque: 0.59 to 0.98 N·m. For Outputs G70V-SOC16P G70V-SOC16P-1 G70V-ZOM16P G70V-ZOM16P-1 G70V-SOC16P-C4 G70V-SOC16P-1-C4 G70V-ZOM16P-C4 G70V-ZOM16P-1-C4 G70V-ZOM16P-C4-D G70V-ZOM16P-1-C4-D 143 max. 4.35 4.2-dia. hole (M4 screw) 4.35 Relay 90 max. 35.2 7.8 7.8 4.35 10.26 4.1 4.35 4.2-dia. hole (M4 screw) 5 20.2 16.7 18.24 29.9 56 max. Note: 1. Relays are not mounted to the G70V-ZOM16P(-1)(-C4)(-D) I/O Terminal Sockets. The dimensions are for when Relays are not mounted. 2. Specified mounting torque: 0.59 to 0.98 N·m. 11 G70V Options (Order Separately) Mountable Relays Slim I/O Relays Models without latching lever G2RV-1-S-G G2RV-1-S-AP-G 5.2 max. 30.5 max. Terminal Arrangement/ Internal Connection Diagram (TOP VIEW) 33 max. 16.2 1.8 0.5 (Input circuit) 14 11 12 A1 A2 2.4 3.5 5.04 5.04 22 3 Slim I/O Relays Models with latching lever (test switch) G2RV-1-SI-G 5.2 max. 30.5 max. Terminal Arrangement/ Internal Connection Diagram (TOP VIEW) (Input circuit) 36 max. 14 11 12 16.2 1.8 0.5 2.4 3.5 5.04 5.04 22 12 3 A1 A2 G70V Slim I/O SSRs G3RV-D03SL G3RV-202S G3RV-202SL Terminal Arrangement/ Internal Connection Diagram (TOP VIEW) G3RV-D03SL (input circuit) Input 30.5 max. Load 33 max. 15.8 14 1.8 3.5 13 G3RV-202S(L) (input circuit) 2.4 22 Input 3 5.04 A1 A2 5.2 max. Load 14 13 A1 A2 Parts for Rail Mounting DIN Track PFP-100N PFP-50N 7.3±0.15 4.5 35±0.3 15 25 10 25 25 1,000 (500)* End Plate PFP-M 10 25 15 (5)* 27±0.15 1 *The dimensions given in parentheses () are for the PFP-50N. 10 6.2 50 Eight M4 pan head screws 1.8 1 35.5 35.3 1.8 11.5 10 M4 spring washers Spacer PFP-S 1.3 4.8 16 12 5 34.8 44.3 16.5 13 G70V Terminal Arrangement/Internal Connection For Inputs G70V-SID16P G70V-SID16P-1 • Supply a power supply that meets the voltage specifications for both the Relays and I/O Relay Terminal to the V and G terminals. Make sure that the polarity is correct. The V terminals are positive and the G terminals are negative. • Supply the rated voltage (24 VDC) of the Controller’s input circuit to the power supply input terminals (V and G). Use a power supply with low noise. Power supply terminal block Communications connector Input Relays (G2RV-1-S-AP-G) Operation indicator (yellow) V V G G V DIN Track mounting hooks I/O Terminal Blocks V V V V V V V V G G G G G G G G V V V V V V V 24 VDC G G G G G G G G 24 VDC For Outputs G70V-SOC16P G70V-SOC16P-1 Power supply terminal block Operation indicator (yellow) Communications connector Output Relays (G2RV-1-S-G) • Supply a power supply that meets the voltage specifications for both the Relays and I/O Relay Terminal to the V and G terminals. Make sure that the polarity is correct. The V terminals are positive and the G terminals are negative. • The terminals (11 to 81, 12 to 82, and 14 to 84) are contact outputs. Supply a suitable power supply for the loads. • The power supply input terminals (V and G) supply power to both drive the Relays and to operate the Controller’s output transistors. Align the voltage specifications of the Controller and the I/O Relay Terminal. DIN Track mounting hooks I/O Terminal Blocks L0 L1 L2 L3 L4 L5 L6 L7 L8 L9 L10 L11 L12 L13 L14 L15 12 22 32 42 52 62 72 82 12 22 32 42 52 62 72 82 V 14 24 34 44 54 64 74 84 14 24 34 44 54 64 74 84 G G 11 21 31 41 51 61 71 81 11 21 31 41 51 61 71 81 AC (DC power supply is also possible.) V 24 VDC 14 G70V For Inputs G70V-SID16P-C16 G70V-SID16P-1-C16 • Supply a power supply that meets the voltage specifications for both the Relays and I/O Relay Terminal to the V and G terminals. Make sure that the polarity is correct. The V terminals are positive and the G terminals are negative. • Supply the rated voltage (24 VDC) of the Controller’s input circuit to the power supply input terminals (V and G). Use a power supply with low noise. Power supply terminal block Communications connector Input Relays (G2RV-1-S-AP-G) Operation indicator (yellow) DIN Track mounting hooks I/O Terminal Blocks G70V-SID16P-C16 V V V G G V V V V V V V G G G G G G G G V V V V V G70V-SID16P-1-C16 V V V 24 VDC G G G G G G G G V V G G V V V V V V V V G G G G G G G G V V V V V V V V 24 VDC G G G G G G G G 24 VDC 24 VDC For Outputs G70V-SOC16P-C4 G70V-SOC16P-1-C4 Power supply terminal block Operation indicator (yellow) Communications connector Output Relays (G2RV-1-S-G) • Supply a power supply that meets the voltage specifications for both the Relays and I/O Relay Terminal to the V and G terminals. Make sure that the polarity is correct. The V terminals are positive and the G terminals are negative. • The terminals (11 to 81, 12 to 82, and 14 to 84) are contact outputs. Supply a suitable power supply for the loads. • The power supply input terminals (V and G) supply power to both drive the Relays and to operate the Controller’s output transistors. Align the voltage specifications of the Controller and the I/O Relay Terminal. DIN Track mounting hooks I/O Terminal Blocks L0 L1 L2 L3 L4 L5 L6 L7 L8 L9 L10 L11 L12 L13 L14 L15 12 22 32 42 52 62 72 82 12 22 32 42 52 62 72 82 V 14 24 34 44 54 64 74 84 14 24 34 44 54 64 74 84 G G 11 21 31 41 51 61 71 81 11 21 31 41 51 61 71 81 AC (DC power supply is also possible.) V 24 VDC 15 G70V For Outputs G70V-ZOM16P-C4-D G70V-ZOM16P-1-C4-D Power supply terminal block Operation indicator (yellow) Communications connector Output Relays* G3RV-D03SL (Relays sold separately.) • Supply a power supply that meets the voltage specifications for both the Relays and I/O Relay Terminal to the V and G terminals. Make sure that the polarity is correct. The V terminals are positive and the G terminals are negative. • The terminals (11 to 81 and 14 to 84) are contact outputs. Supply a suitable power supply for the loads. Make sure that polarity of the output terminal is correct. • The power supply input terminals (V and G) supply power to both drive the Relays and to operate the Controller’s output transistors. Align the voltage specifications of the Controller and the I/O Relay Terminal. DIN Track mounting hooks I/O Terminal Blocks 12 22 32 42 52 62 72 82 12 22 32 42 52 62 72 82 V 14 24 34 44 54 64 74 84 14 24 34 44 54 64 74 84 G G 11 21 31 41 51 61 71 81 11 21 31 41 51 61 71 81 L0 L1 L2 L3 L4 L5 L6 L7 L8 L9 L10 L11 L12 L13 L14 L15 V 24 VDC 16 DC * The G70V-ZOM16P(-1)-C4-D does not come with SSRs. Use Slim I/O SSRs (for DC: G3RV-D03SL). G70V Safety Precautions Be sure to read The Safety Precautions for All I/O Relay Terminals in the website at the following URL: http://www.ia.omron.com/product/cautions/46/243/index.html. Warning Indications Precautions for Safe Use Supplementary comments on what to do or avoid doing, to use the product safely. Precautions for Correct Use Supplementary comments on what to do or avoid doing, to prevent failure to operate, malfunction, or undesirable effects on product performance. Precautions for Safe Use Transportation • Do not transport the I/O Relay Terminal under the following locations. Doing so may occasionally result in damage, malfunction, or deterioration of performance characteristics. • Locations subject to water or oil • Locations subject to high temperature or high humidity • Locations subject to condensation due to rapid changes in temperature Operating and Storage Environments • Do not use or store the I/O Relay Terminal in the following locations. Doing so may result in damage, malfunction, or deterioration of performance characteristics. • Locations subject to rainwater or water splashes • Locations subject to exposure to water, oil, or chemicals • Locations subject to high temperature or high humidity • Locations subject to ambient storage temperatures outside the range −40 to 65°C • Locations subject to ambient operating temperatures outside the range −40 to 55°C • Locations subject to relative humidity outside the range 35% to 85% or locations in which condensation may occur due to rapid changes in temperature • Locations subject to corrosive gases or inflammable gases • Locations subject to dust, salts, or iron, or locations where there is salt damage • Locations subject to direct sunlight • Locations subject to shock or vibration Installation and Mounting • Mount the I/O Relay Terminal in the specified direction. Otherwise excessive heat generated by the I/O Relay Terminal may occasionally cause burning. • Mount the I/O Relay Terminal firmly to a DIN Track. Otherwise, the I/O Relay Terminal may fall off. • Do not handle the I/O Relay Terminal with oily or dusty (especially iron dust) hands. • Make sure that there is no excessive ambient temperature rise due to the heat generation of the I/O Relay Terminal. If the I/O Relay Terminal is mounted inside a panel, install a fan so that the interior of the panel is fully ventilated. Push-In Plus Terminal Blocks • Do not wire anything to the release holes. • Do not tilt or twist a flat-blade screwdriver while it is inserted into a release hole on the terminal block. The terminal block may be damaged. • Insert a flat-blade screwdriver into the release holes at an angle. The terminal block may be damaged if you insert the screwdriver straight in. • Do not allow the flat-blade screwdriver to fall out while it is inserted into a release hole. • Do not bend a wire past its natural bending radius or pull on it with excessive force. Doing so may cause the wire disconnection. • Do not insert more than one wire into each terminal insertion hole. • To prevent wire materials from smoking or igniting, confirm wire ratings and use the wiring materials given in the following table. Stripping length (Ferrules not used) Recommended wire gauge 0.25 to 1.5mm2/AWG24 to 16 8 mm • Refer to the following table for wire sizes for external I/O devices according to the current flow. AWG24 to AWG20 Maximum current flow: 6 A AWG18 to AWG16 Maximum current flow: 10 A Application • Select a load within the rated values. Not doing so may result in malfunction, failure, or burning. • The I/O Relay Terminal may occasionally rupture if short-circuit current flows. As protection against accidents due to shortcircuiting, be sure to install protective devices, such as fuses and no-fuse breakers, on the power supply side. • Use a power supply within the rated frequencies. Otherwise, malfunction, failure, or burning may occasionally occur. • Minor electric shock may occasionally occur. Always turn OFF the power supply before performing wiring. Precautions for Correct Use • Do not drop the I/O Relay Terminal or subject it to abnormal vibration or shock during transportation or mounting. Doing so may result in deterioration of performance, malfunction, or failure. • Do not transport an I/O Relay Terminal when it is not packaged. Damage or failure may occur. • Use a power supply with low noise. Push-In Plus Terminal Blocks 1. Connecting Wires to the Push-In Plus Terminal Block Part Names of the Terminal Block Release hole Terminal (Insertion) hole Installation and Wiring • Use wires that are suited to the load current and voltage. Otherwise, excessive heat generated by the wires may cause burning or may cause the wire covering to melt, possibly leading to electric shock. • Do not use wires with a damaged outer covering. Otherwise, it may result in electric shock or ground leakage. • Do not wire any wiring in the same duct or conduit as power or high-tension lines. Otherwise, inductive noise may damage the I/O Relay Terminal or cause it to malfunction. • Do not apply a voltage or current that exceeds the rating to any terminal. Doing so may result in failure or burning. Connecting Wires with Ferrules and Solid Wires Insert the solid wire or ferrule straight into the terminal block until the end strikes the terminal block. Release hole Terminal (Insertion) hole Ferrules and solid wires • If a wire is difficult to connect because it is too thin, use a flat-blade screwdriver in the same way as when connecting stranded wire. 17 G70V Connecting Stranded Wires Use the following procedure to connect the wires to the terminal block. 1. Hold a flat-blade screwdriver at an angle and insert it into the release hole. The angle should be between 10° and 15°. If the flat-blade screwdriver is inserted correctly, you will feel the spring in the release hole. 2. With the flat-blade screwdriver still inserted into the release hole, insert the wire into the terminal hole until it strikes the terminal block. 3. Remove the flat-blade screwdriver from the release hole. Flat-blade screwdriver 3 1 3 3. Recommended Ferrules and Crimp Tools Recommended ferrules Applicable wire Stripping Ferrule length Conductor [mm] length (Ferrules (mm2) (AWG) (mm) used) 0.25 10 to 15° 0.5 Stranded Wires Checking Connections • After the insertion, pull gently on the wire to make sure that it will not come off and the wire is securely fastened to the terminal block. • If you use a ferrule with a conductor length of 10 mm, part of the conductor may be visible after the ferrule is inserted into the terminal block, but the product insulation distance will still be satisfied. 2. Removing Wires from the Push-In Plus Terminal Block Use the following procedure to remove wires from the terminal block. The same method is used to remove stranded wires, solid wires, and ferrules. 1. Hold a flat-blade screwdriver at an angle and insert it into the release hole. 2. With the flat-blade screwdriver still inserted into the release hole, remove the wire from the terminal insertion hole. 3. Remove the flat-blade screwdriver from the release hole. 1 8 10 AI0,25-8 10 12 AI0,25-10 Weidmuller product H0.25/12 Wago product 216-301 8 10 AI0,34-8 10 12 AI0,34-10 --H0.34/12 --216-302 22 --- --- 8 10 AI0,5-8 H0.5/14 216-201 10 12 AI0,5-10 H0.5/16 216-241 8 10 AI0,75-8 H0.75/14 216-202 20 2 2 Phoenix Contact product 24 0.34 1 Recommended ferrules 0.75 18 12 AI0,75-10 H0.75/16 216-242 8 10 AI1-8 H1.0/14 216-203 10 12 AI1-10 H1.0/16 216-243 8 10 AI1,5-8 H1.5/14 216-204 10 12 AI1,5-10 H1.5/16 216-244 10 1/1.25 18/17 1.25/1.5 17/16 Recommended crimp tool CRIMPFOX6 CRIMPFOX6T-F PZ6 roto CRIMPFOX10S Variocrimp4 Note: 1. Make sure that the outer diameter of the wire coating is smaller than the inner diameter of the insulation sleeve of the recommended ferrule. 2. Make sure that the ferrule processing dimensions conform to the following figures. 8 to 10 mm Flat-blade screwdriver 3 3 1 10 to 15° 2 2 Wire 2.6 mm max. 1.9 mm max. Recommended Flat-blade Screwdriver Use a flat-blade screwdriver to connect and remove wires. Use the following flat-blade screwdriver. The following table shows manufacturers and models as of 2015/Dec. Side Front 2.5 mm dia. 0.4 mm 2.5 mm Model Manufacturer ESD 0,40×2,5 Wera SZS 0,4×2,5 SZF 0-0,4×2,5 * Phoenix Contact 0.4×2.5×75 302 Wiha AEF.2,5×75 Facom 210-719 Wago SDI 0.4×2.5×75 Weidmuller * OMRON's exclusive purchase model XW4Z-00B is available to order as SZF 0-0,4 × 2,5 (manufactured by Phoenix Contact). 18 G70V Connecting Cables Refer to the datasheet for the XW2Z-R Cables for I/O Relay Terminals (Cat. No. G126). Type Name Cables with Loose Wires and Crimp Terminals I/O Classification Appearance Cable length L (mm) B side A side Device end I/O Relay Terminal 16 I/O points XW2Z-RYC Various devices L 300 Cables with Loose Wires Models 1,000 XW2Z-RY100C 1,500 XW2Z-RY150C 2,000 XW2Z-RY200C 3,000 XW2Z-RY300C 5,000 XW2Z-RY500C 2,000 XW2Z-RA200C 5,000 XW2Z-RA500C 1,000 XW2Z-R100C 1,500 XW2Z-R150C 2,000 XW2Z-R200C 3,000 XW2Z-R300C 16 I/O points XW2Z-RAC L 300 Fujitsu connectors (24 pins) Cables with Connectors (1:1) 16 I/O points XW2Z-RC L 5,000 (A) 32 input points Cables with Connectors (1:2) Fujitsu connectors (40 pins) (120) XW2Z-RIC- XW2Z-ROC- 32 output points (B) Straight length (without bends) (A) (B) Fujitsu connectors (56 pins) Cables with Connectors (1:3) 48 I/O points (120) XW2Z-R500C (A) 1,000 (B) 750 XW2Z-RI100C-75 (A) 1,500 (B) 1,250 XW2Z-RI150C-125 (A) 2,000 (B) 1,750 XW2Z-RI200C-175 (A) 3,000 (B) 2,750 XW2Z-RI300C-275 (A) 5,000 (B) 4,750 XW2Z-RI500C-475 (A) 1,000 (B) 750 XW2Z-RO100C-75 (A) 1,500 (B) 1,250 XW2Z-RO150C-125 (A) 2,000 (B) 1,750 XW2Z-RO200C-175 (A) 3,000 (B) 2,750 XW2Z-RO300C-275 (A) 5,000 (B) 4,750 XW2Z-RO500C-475 (A) 1,500 (B) 1,250 (C) 1,000 XW2Z-R150C-125-100 (A) 2,000 (B) 1,750 (C) 1,500 XW2Z-R200C-175-150 (A) 3,000 (B) 2,750 (C) 2,500 XW2Z-R300C-275-250 (270) XW2Z-RC-- (C) Straight length (without bends) Cables with Connectors (1:1) MIL connectors (20 pins) 16 I/O points XW2Z-RIC XW2Z-ROC 250 XW2Z-RI25C 500 XW2Z-RI50C 250 XW2Z-RO25C 500 XW2Z-RO50C L 19 G70V Type Name I/O Classification Appearance B side A side Device end Cables with Connectors (1:2) MIL connectors (40 pins) I/O Relay Terminal 32 I/O points XW2Z-RO--D1, XW2Z-RI--D1, XW2Z-RI--D2, XW2Z-RM--D1 *1, XW2Z-RM--D2 *1 Cable length L (mm) (A) (120) (B) Straight length (without bends) 16 inputs and 16 outputs (32 I/O points) (A) 32 input points Mitsubishi Electric PLCs with 32-point connectors (1:2) *2 Mitsubishi Electric PLC Connecting Cables (120) XW2Z-RIC--MN XW2Z-ROC--MN 32 output points (B) 250 XW2Z-RO50-25-D1 (A) 750 (B) 500 XW2Z-RO75-50-D1 (A) 1,000 (B) 750 XW2Z-RO100-75-D1 (A) 1,500 (B) 1,250 XW2Z-RO150-125-D1 (A) 2,000 (B) 1,750 XW2Z-RO200-175-D1 (A) 3,000 (B) 2,750 XW2Z-RO300-275-D1 (A) 5,000 (B) 4,750 XW2Z-RO500-475-D1 (A) 500 (B) 250 XW2Z-RI50-25-D1 (A) 750 (B) 500 XW2Z-RI75-50-D1 (A) 1,000 (B) 750 XW2Z-RI100-75-D1 (A) 1,500 (B) 1,250 XW2Z-RI150-125-D1 (A) 2,000 (B) 1,750 XW2Z-RI200-175-D1 (A) 3,000 (B) 2,750 XW2Z-RI300-275-D1 (A) 5,000 (B) 4,750 XW2Z-RI500-475-D1 (A) 500 (B) 250 XW2Z-RI50-25-D2 (A) 750 (B) 500 XW2Z-RI75-50-D2 (A) 500 (B) 250 XW2Z-RM50-25-D1 (A) 750 (B) 500 XW2Z-RM75-50-D1 (A) 500 (B) 250 XW2Z-RM50-25-D2 (A) 750 (B) 500 XW2Z-RM75-50-D2 (A) 1,000 (B) 750 XW2Z-RI100C-75-MN (A) 1,500 (B) 1,250 XW2Z-RI150C-125-MN (A) 2,000 (B) 1,750 XW2Z-RI200C-175-MN (A) 3,000 (B) 2,750 XW2Z-RI300C-275-MN (A) 1,000 (B) 750 XW2Z-RO100C-75-MN (A) 1,500 (B) 1,250 XW2Z-RO150C-125-MN (A) 2,000 (B) 1,750 XW2Z-RO200C-175-MN (B) Straight length (without bends) (A) 3,000 (A) 32 input points Schneider Electric PLCs with 32-point connectors (1:2) Applicable models: For inputs: 140 DDI 353 00 For outputs: 140 DDO 353 00 (120) 32 output points (B) Straight length (without bends) Schneider Electric PLC Connecting Cables XW2Z-R@C-SCH-@ Schneider Electric PLCs with 16-point connectors (1:1) Applicable models: For inputs: BMX DDI 1602 For outputs: BMX DDO 1602 Models (A) 500 16 input points (B) 2,750 XW2Z-RO300C-275-MN 500 XW2Z-R050C-SCH-A 1,000 XW2Z-R100C-SCH-A 2,000 XW2Z-R200C-SCH-A 3,000 XW2Z-R300C-SCH-A 5,000 XW2Z-R500C-SCH-A 500 XW2Z-R050C-SCH-B 1,000 XW2Z-R100C-SCH-B 2,000 XW2Z-R200C-SCH-B 3,000 XW2Z-R300C-SCH-B 5,000 XW2Z-R500C-SCH-B 500 XW2Z-R050C-SCH-C 1,000 XW2Z-R100C-SCH-C 2,000 XW2Z-R200C-SCH-C 3,000 XW2Z-R300C-SCH-C 5,000 XW2Z-R500C-SCH-C 500 XW2Z-R050C-SCH-D 1,000 XW2Z-R100C-SCH-D 2,000 XW2Z-R200C-SCH-D 3,000 XW2Z-R300C-SCH-D 5,000 XW2Z-R500C-SCH-D L 16 output points Note: Contact for a cable length other than the above. Cables that can be connected to the QX81, QX81-S2, and QY81P have not been prepared. *1. These cables are used to connect to slave products for DeviceNet and other networks. *2. For details on models that can be used, refer to List of Combinations with the Mitsubishi PLC MELSEC-L Series, MELSEC-Q Series, and MELSEC iQ-R Series on page 26. 20 G70V Type Name I/O Classification Appearance Siemens PLCs with 32-point connectors (1:2) 500 XW2Z-R050C-SIM-A 1,000 XW2Z-R100C-SIM-A I/O Relay Terminal 2,000 XW2Z-R200C-SIM-A 3,000 XW2Z-R300C-SIM-A 5,000 XW2Z-R500C-SIM-A 500 XW2Z-R050C-SIM-B 1,000 XW2Z-R100C-SIM-B 2,000 XW2Z-R200C-SIM-B 3,000 XW2Z-R300C-SIM-B (A) Applicable models: For inputs: 6ES7 321-1BL00-0AA0 For outputs: 6ES7 322-1BL00-0AA0 Siemens PLCs with 16-point connectors (1:1) Applicable models: For inputs: 6ES7 321-1BH02-0AA0 Siemens PLCs with 32-point connectors (1:2) Applicable models: For inputs: 6ES7 421-1BL-0AA0 For outputs: 6ES7 422-1BL-0AA0 Device end (120) 32 output points Siemens PLC Connecting Cables (B) Straight length (without bends) 16 input points XW2Z-R@C-SIM-@ L (A) 32 input points (120) 32 output points Models B side A side 32 input points Cable length L (mm) (B) Straight length (without bends) 5,000 XW2Z-R500C-SIM-B 500 XW2Z-R050C-SIM-C 1,000 XW2Z-R100C-SIM-C 2,000 XW2Z-R200C-SIM-C 3,000 XW2Z-R300C-SIM-C 5,000 XW2Z-R500C-SIM-C 500 XW2Z-R050C-SIM-D 1,000 XW2Z-R100C-SIM-D 2,000 XW2Z-R200C-SIM-D 3,000 XW2Z-R300C-SIM-D 5,000 XW2Z-R500C-SIM-D 500 XW2Z-R050C-SIM-E 1,000 XW2Z-R100C-SIM-E 2,000 XW2Z-R200C-SIM-E 3,000 XW2Z-R300C-SIM-E 5,000 XW2Z-R500C-SIM-E Note: 1. Refer to Combinations of Connections starting on the next page. 2. For connector pin diagrams and cable colors, refer to the wiring diagrams starting on page 4 of XW2Z-R Cables for I/O Relay Terminals (Cat. No. G126). 21 G70V Combinations of Connections Refer to the next page for details on the combinations of cables and connection devices [OMRON PLC I/O Units NX Series, CJ Series, CS Series], [Mitsubishi PLC I/O Units MELSEC-L Series, MELSEC-Q Series, MELSEC iQ-R Series]. For combinations with other products, refer to I/O Relay Terminals and Connected Devices (Cat. No. J217) or to the datasheets for related products. Connection Patterns Pattern Configuration Connecting Cable I/O Relay Terminals A I/O Relay Terminals I/O Relay Terminals B Connecting Cable I/O Relay Terminals I/O Relay Terminals D Connecting Cable E I/O Relay Terminals I/O Relay Terminals Connecting Cable Connecting Cable F I/O Relay Terminals 22 G70V List of Combinations with the OMRON PLC NX Series NX I/O Units I/O capacity Model External connectors Polarity XW2Z-R Cables Conne ction Model *1 pattern Specifications G70V I/O Relay Terminals Quantity required Model Quantity required G70V-SID16P(-1)(-C16) 1 G70V-SID16P(-1)(-C16) 2 G70V-SID16P(-1)(-C16) 2 Specifications Input Units 16 inputs NX-ID5142-5 1 MIL connector NPN or PNP NX-ID6142-5 1 MIL connector NPN or PNP NX-ID6142-6 1 Fujitsu connector NPN or PNP 32 inputs F 1:1 A 1:2 F 1:1 XW2Z-RO@C 1 XW2Z-RO@-@-D1 1 XW2Z-RI@C-@ 1 XW2Z-RO@C 1 NPN outputs G70V-SOC16P(-C4) 1 XW2Z-RO@C 1 PNP outputs G70V-SOC16P-1(-C4) 1 XW2Z-RO@-@-D1 1 NPN outputs G70V-SOC16P(-C4) 2 --- --- PNP outputs --- --- XW2Z-RO@C-@ 1 NPN outputs G70V-SOC16P(-C4) 2 Inputs *2 G70V-SID16P(-1)(-C16) 1 XW2Z-R@C 2 NPN outputs G70V-SOC16P(-C4) 1 XW2Z-RO@C 1 Inputs *2 G70V-SID16P(-1)(-C16) 1 XW2Z-RO@C 1 NPN outputs G70V-SOC16P(-C4) 1 XW2Z-RO@C 1 Inputs *2 G70V-SID16P(-1)(-C16) 1 XW2Z-RI@C 1 PNP outputs G70V-SOC16P-1(-C4) 1 Inputs *2 Output Units 16 outputs 32 outputs NX-OD5121-5 1 MIL connector NPN NX-OD5256-5 1 MIL connector PNP NX-OD6121-5 1 MIL connector NPN NX-OD6256-5 1 MIL connector PNP NX-OD6121-6 1 Fujitsu connector NPN A 1:2 Mixed I/O Units 16 inputs and 16 outputs 2 Fujitsu connectors NX-MD6121-6 (1 for 16 inputs and 1 for 16 outputs) Outputs: NPN Inputs: NPN or PNP 2 MIL connectors NX-MD6121-5 (1 for 16 inputs and 1 for 16 outputs) Outputs: NPN Inputs: NPN or PNP 2 MIL connectors NX-MD6256-5 (1 for 16 inputs and 1 for 16 outputs) Outputs: PNP Inputs: NPN or PNP E 1:1 *1. The box @ is replaced by the cable length. *2. Either NPN inputs or PNP inputs can be used. 23 G70V List of Combinations with the OMRON PLC CJ Series CJ1W I/O Units I/O capacity Model External connectors *1 Polarity Conne ction pattern XW2Z-R Cables Specifications Model *2 G70V I/O Relay Terminals Quantity required Model Quantity required G70V-SID16P(-1)(-C16) 2 G70V-SID16P(-1)(-C16) 4 NPN outputs G70V-SOC16P(-C4) 2 Specifications DC Input Units 1 Fujitsu connector NPN 32 inputs CJ1W-ID232 CJ1W-ID231 1 MIL connector NPN XW2Z-RI@C-@ 1 XW2Z-RO@-@-D1 CJ1W-ID233 1 MIL connector NPN 1 XW2Z-RO@-@-D1 1 CJ1W-ID261 2 Fujitsu connectors (2, 32-point connectors) NPN XW2Z-RI@C-@ 2 CJ1W-ID262 2 MIL connectors (2, 32-point connectors) NPN XW2Z-RO@-@-D1 2 CJ1W-OD231 1 Fujitsu connector Sinking (NPN) XW2Z-RO@C-@ 1 CJ1W-OD233 1 MIL connector Sinking (NPN) XW2Z-RO@-@-D1 1 CJ1W-OD232 1 MIL connector Sourcing (PNP) XW2Z-RO@-@-D1 1 PNP outputs G70V-SOC16P-1(-C4) 2 CJ1W-OD234 1 MIL connector Sinking (NPN) XW2Z-RO@-@-D1 1 NPN outputs G70V-SOC16P(-C4) 2 CJ1W-OD261 2 Fujitsu connectors (2, 32-point connectors) Sinking (NPN) XW2Z-RO@C-@ 2 NPN outputs G70V-SOC16P(-C4) 4 CJ1W-OD262 2 MIL connectors (2, 32-point connectors) Sourcing (PNP) XW2Z-RO@-@-D1 2 PNP outputs G70V-SOC16P-1(-C4) 4 CJ1W-OD263 2 MIL connectors (2, 32-point connectors) Sinking (NPN) XW2Z-RO@-@-D1 2 NPN outputs G70V-SOC16P(-C4) 4 Inputs *3 G70V-SID16P(-1)(-C16) 1 XW2Z-R@C 2 NPN outputs G70V-SOC16P(-C4) 1 64 inputs A 1:2 Inputs *3 B Transistor Output Units 32 outputs 64 outputs A 1:2 B DC Input/Transistor Output Units 16 inputs and 16 outputs 32 inputs and 32 outputs CJ1W-MD231 2 Fujitsu connectors (1 for 16 inputs and 1 for 16 outputs) Sinking (NPN) CJ1W-MD233 2 MIL connectors (1 for 16 inputs and 1 for 16 outputs) Sinking (NPN) CJ1W-MD232 2 MIL connectors (1 for 16 inputs and 1 for 16 outputs) Sourcing (PNP) CJ1W-MD261 2 Fujitsu connectors (1 for 32 inputs and 1 for 32 outputs) Sinking (NPN) 2 MIL connectors (1 for 32 inputs and 1 for 32 outputs) Sinking (NPN) CJ1W-MD263 E B 1:1 1:2 *1. For details on the types of connectors, refer to pages 19 and 20. *2. The box @ is replaced by the cable length. *3. Either NPN inputs or PNP inputs can be used. 24 XW2Z-RO@C 1 Inputs *3 G70V-SID16P(-1)(-C16) 1 XW2Z-RO@C 1 NPN outputs G70V-SOC16P(-C4) 1 XW2Z-RO@C 1 Inputs *3 G70V-SID16P(-1)(-C16) 1 XW2Z-RI@C 1 PNP outputs G70V-SOC16P-1(-C4) 1 XW2Z-RI@C-@ 1 Inputs *3 G70V-SID16P(-1)(-C16) 2 XW2Z-RO@C-@ 1 NPN outputs G70V-SOC16P(-C4) 2 XW2Z-RO@-@-D1 1 Inputs *3 G70V-SID16P(-1)(-C16) 2 XW2Z-RO@-@-D1 1 NPN outputs G70V-SOC16P(-C4) 2 G70V List of Combinations with the OMRON PLC CS Series CJ1W I/O Units I/O capacity Model External connectors *1 Polarity Conne ction pattern NPN A XW2Z-R Cables Specifications G70V I/O Relay Terminals Model *2 Quantity required Model Quantity required XW2Z-RI@C-@ 1 G70V-SID16P(-1)(-C16) 2 XW2Z-RI@C-@ 2 G70V-SID16P(-1)(-C16) 4 XW2Z-R@C-@-@ 2 G70V-SID16P(-1)(-C16) 6 XW2Z-RO@C-@ 1 NPN outputs G70V-SOC16P(-C4) 2 XW2Z-RO@C-@ 1 PNP outputs G70V-SOC16P-1(-C4) 2 XW2Z-RO@C-@ 2 NPN outputs G70V-SOC16P(-C4) 4 XW2Z-RO@C-@ 2 PNP outputs G70V-SOC16P-1(-C4) 4 XW2Z-R@C-@-@ 2 NPN outputs G70V-SOC16P(-C4) 6 XW2Z-RI@C-@ 1 Inputs *3 G70V-SID16P(-1)(-C16) 2 XW2Z-RO@C-@ 1 NPN outputs G70V-SOC16P(-C4) 2 XW2Z-RI@C-@ 1 Inputs *3 G70V-SID16P(-1)(-C16) 2 XW2Z-RO@C-@ 1 PNP outputs G70V-SOC16P-1(-C4) 2 Inputs *3 G70V-SID16P(-1)(-C16) 3 NPN outputs G70V-SOC16P(-C4) 3 Inputs *3 G70V-SID16P(-1)(-C16) 3 Specifications DC Input Units 32 inputs CS1W-ID231 1 Fujitsu connector 64 inputs CS1W-ID261 2 Fujitsu connectors (2, 32-point connectors) NPN B 96 inputs CS1W-ID291 2 Fujitsu connectors (2, 48-point connectors) NPN D 1:2 1:3 Inputs *3 Transistor Output Units 32 outputs 64 outputs 96 outputs CS1W-OD231 1 Fujitsu connector CS1W-OD232 1 Fujitsu connector Sinking (NPN) Sourcing (PNP) 2 Fujitsu connectors (2, 32-point connectors) Sinking (NPN) CS1W-OD262 2 Fujitsu connectors (2, 32-point connectors) Sourcing (PNP) CS1W-OD291 2 Fujitsu connectors (2, 48-point connectors) Sinking (NPN) CS1W-OD261 A 1:2 B D 1:3 DC Input/Transistor Output Units 32 inputs and 32 outputs 48 inputs and 48 outputs CS1WMD261 2 Fujitsu connectors (1 for 32 inputs and 1 for 32 outputs) CS1WMD262 2 Fujitsu connectors (1 for 32 inputs and 1 for 32 outputs) CS1WMD291 2 Fujitsu connectors (1 for 48 inputs and 1 for 48 outputs) CS1WMD292 2 Fujitsu connectors (1 for 48 inputs and 1 for 48 outputs) Sinking (NPN) B 1:2 Sourcing (PNP) Sinking (NPN) D 1:3 Sourcing (PNP) XW2Z-R@C-@-@ 2 XW2Z-R@C-@-@ 1 --- *1. For details on the types of connectors, refer to pages 19 and 20. *2. The box @ is replaced by the cable length. *3. Either NPN inputs or PNP inputs can be used. Refer to the manuals for the connected PLC for the connections to I/O Units for OMRON PLCs. Series Model Man. No. Manual Name CS1 CS1G-CPUH, CS1H-CPUH W339 Programmable Controllers Operation Manual CJ1 CJ1H-CPUH-R, CJ1G/H-CPUH, CJ1GCPUP, CJ1M-CPU, CJ1G-CPU W393 CJ Series Programmable Controllers Operation Manual CJ2 CJ2H-CPU6-EIP, CJ2H-CPU6, CJ2M-CPU W472 CJ-series CJ2 CPU Unit Hardware User’s Manual NJ NJ501- W500 NJ-series CPU Unit Hardware User's Manual NX NX-ID, NX-IA, NX-OD, NX-OC, NX-MD W521 NX-series Digital I/O Units User’s Manual 25 G70V List of Combinations with the Mitsubishi PLC MELSEC-L Series, MELSEC-Q Series, and MELSEC iQ-R Series PLC I/O Unit I/O capacity Model External connectors Conne ction pattern XW2Z-R Cables G70V I/O Relay Terminals Quantity required Specifications XW2Z-RI@@@ -@@MN 1 Inputs *2 G70V-SID16P(-1)(-C16) 2 XW2Z-RI@@@ -@@MN 2 Inputs *2 G70V-SID16P(-1)(-C16) 4 XW2Z-RO@@@ -@@MN 1 NPN outputs G70V-SOC16P(-C4) 2 XW2Z-RO@@@ -@@MN 1 PNP outputs G70V-SOC16P-1(-C4) 2 XW2Z-RO@@@ -@@MN 2 NPN outputs G70V-SOC16P(-C4) 4 PNP XW2Z-RO@@@ -@@MN 2 PNP outputs G70V-SOC16P-1(-C4) 4 NPN or PNP XW2Z-RI@@@ -@@MN 1 Inputs *2 G70V-SID16P(-1)(-C16) 2 NPN XW2Z-RO@@@ -@@MN 1 NPN outputs G70V-SOC16P(-C4) 2 NPN or PNP XW2Z-RI@@@ -@@MN 1 Inputs *2 G70V-SID16P(-1)(-C16) 2 NPN XW2Z-RO@@@ -@@MN 1 NPN outputs G70V-SOC16P(-C4) 2 NPN or PNP XW2Z-RI@@@ -@@MN 1 Inputs *2 G70V-SID16P(-1)(-C16) 2 NPN XW2Z-RO@@@ -@@MN 1 NPN outputs G70V-SOC16P(-C4) 2 NPN or PNP XW2Z-RI@@@ -@@MN 1 Inputs *2 G70V-SID16P(-1)(-C16) 2 NPN XW2Z-RO@@@ -@@MN 1 NPN outputs G70V-SOC16P(-C4) 2 NPN or PNP XW2Z-RI@@@ -@@MN 1 Inputs *2 G70V-SID16P(-1)(-C16) 2 PNP XW2Z-RO@@@ -@@MN 1 PNP outputs G70V-SOC16P-1(-C4) 2 Polarity Specifications Model *1 Model Quantity required Input Units LX41C4 32 inputs QX41/QX41-S1/ QX41-S2 QX71 1 Fujitsu connector RX41C4 NPN or PNP LX42C4 QX42/QX42-S1 64 inputs QX82/QX82-S1 A 2 Fujitsu connectors 1:2 B RX42C4 Output Units LY41NT1P QY41P QY71 32 outputs 1 Fujitsu connector NPN RY41NT2P A LY41PT1P RY41PT1P 1 Fujitsu connector PNP RY41PT2H 1:2 LY42NT1P RY42NT2P 64 outputs 2 Fujitsu connectors NPN QY42P B LY42PT1P RY42PT1P 2 Fujitsu connectors QY82P Mixed I/O Units RH42C4NT2P (Input side) RH42C4NT2P (Output side) QH42P (Input side) QH42P (Output side) 32 inputs and 32 outputs QX41Y41P (Input side) QX41Y41P (Output side) LH42C4NT1P (Input side) LH42C4NT1P (Output side) LH42C4PT1P (Input side) LH42C4PT1P (Output side) 2 Fujitsu connectors 2 Fujitsu connectors 2 Fujitsu connectors 2 Fujitsu connectors 2 Fujitsu connectors B 1:2 Note: Cables that can be connected to the QX81, QX81-S2, and QY81P have not been prepared. *1. The box @ is replaced by the cable length. For details on the types, refer to page 20. *2. Either NPN inputs or PNP inputs can be used. 26 Terms and Conditions Agreement Read and understand this catalog. Please read and understand this catalog before purchasing the products. Please consult your OMRON representative if you have any questions or comments. Warranties. (a) Exclusive Warranty. Omron’s exclusive warranty is that the Products will be free from defects in materials and workmanship for a period of twelve months from the date of sale by Omron (or such other period expressed in writing by Omron). Omron disclaims all other warranties, express or implied. (b) Limitations. OMRON MAKES NO WARRANTY OR REPRESENTATION, EXPRESS OR IMPLIED, ABOUT NON-INFRINGEMENT, MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE OF THE PRODUCTS. BUYER ACKNOWLEDGES THAT IT ALONE HAS DETERMINED THAT THE PRODUCTS WILL SUITABLY MEET THE REQUIREMENTS OF THEIR INTENDED USE. Omron further disclaims all warranties and responsibility of any type for claims or expenses based on infringement by the Products or otherwise of any intellectual property right. (c) Buyer Remedy. Omron’s sole obligation hereunder shall be, at Omron’s election, to (i) replace (in the form originally shipped with Buyer responsible for labor charges for removal or replacement thereof) the non-complying Product, (ii) repair the non-complying Product, or (iii) repay or credit Buyer an amount equal to the purchase price of the non-complying Product; provided that in no event shall Omron be responsible for warranty, repair, indemnity or any other claims or expenses regarding the Products unless Omron’s analysis confirms that the Products were properly handled, stored, installed and maintained and not subject to contamination, abuse, misuse or inappropriate modification. Return of any Products by Buyer must be approved in writing by Omron before shipment. Omron Companies shall not be liable for the suitability or unsuitability or the results from the use of Products in combination with any electrical or electronic components, circuits, system assemblies or any other materials or substances or environments. Any advice, recommendations or information given orally or in writing, are not to be construed as an amendment or addition to the above warranty. See http://www.omron.com/global/ or contact your Omron representative for published information. Limitation on Liability; Etc. OMRON COMPANIES SHALL NOT BE LIABLE FOR SPECIAL, INDIRECT, INCIDENTAL, OR CONSEQUENTIAL DAMAGES, LOSS OF PROFITS OR PRODUCTION OR COMMERCIAL LOSS IN ANY WAY CONNECTED WITH THE PRODUCTS, WHETHER SUCH CLAIM IS BASED IN CONTRACT, WARRANTY, NEGLIGENCE OR STRICT LIABILITY. Further, in no event shall liability of Omron Companies exceed the individual price of the Product on which liability is asserted. Suitability of Use. Omron Companies shall not be responsible for conformity with any standards, codes or regulations which apply to the combination of the Product in the Buyer’s application or use of the Product. At Buyer’s request, Omron will provide applicable third party certification documents identifying ratings and limitations of use which apply to the Product. This information by itself is not sufficient for a complete determination of the suitability of the Product in combination with the end product, machine, system, or other application or use. Buyer shall be solely responsible for determining appropriateness of the particular Product with respect to Buyer’s application, product or system. Buyer shall take application responsibility in all cases. NEVER USE THE PRODUCT FOR AN APPLICATION INVOLVING SERIOUS RISK TO LIFE OR PROPERTY OR IN LARGE QUANTITIES WITHOUT ENSURING THAT THE SYSTEM AS A WHOLE HAS BEEN DESIGNED TO ADDRESS THE RISKS, AND THAT THE OMRON PRODUCT(S) IS PROPERLY RATED AND INSTALLED FOR THE INTENDED USE WITHIN THE OVERALL EQUIPMENT OR SYSTEM. Programmable Products. Omron Companies shall not be responsible for the user’s programming of a programmable Product, or any consequence thereof. Performance Data. Data presented in Omron Company websites, catalogs and other materials is provided as a guide for the user in determining suitability and does not constitute a warranty. It may represent the result of Omron’s test conditions, and the user must correlate it to actual application requirements. Actual performance is subject to the Omron’s Warranty and Limitations of Liability. Change in Specifications. Product specifications and accessories may be changed at any time based on improvements and other reasons. It is our practice to change part numbers when published ratings or features are changed, or when significant construction changes are made. However, some specifications of the Product may be changed without any notice. When in doubt, special part numbers may be assigned to fix or establish key specifications for your application. Please consult with your Omron’s representative at any time to confirm actual specifications of purchased Product. Errors and Omissions. Information presented by Omron Companies has been checked and is believed to be accurate; however, no responsibility is assumed for clerical, typographical or proofreading errors or omissions. OMRON Corporation Industrial Automation Company Authorized Distributor: Kyoto, JAPAN Contact: www.ia.omron.com Regional Headquarters OMRON EUROPE B.V. Wegalaan 67-69, 2132 JD Hoofddorp The Netherlands Tel: (31)2356-81-300/Fax: (31)2356-81-388 OMRON ELECTRONICS LLC 2895 Greenspoint Parkway, Suite 200 Hoffman Estates, IL 60169 U.S.A. Tel: (1) 847-843-7900/Fax: (1) 847-843-7787 OMRON ASIA PACIFIC PTE. LTD. No. 438A Alexandra Road # 05-05/08 (Lobby 2), Alexandra Technopark, Singapore 119967 Tel: (65) 6835-3011/Fax: (65) 6835-2711 OMRON (CHINA) CO., LTD. Room 2211, Bank of China Tower, 200 Yin Cheng Zhong Road, PuDong New Area, Shanghai, 200120, China Tel: (86) 21-5037-2222/Fax: (86) 21-5037-2200 © OMRON Corporation 2016-2018 All Rights Reserved. In the interest of product improvement, specifications are subject to change without notice. CSM_2_9_1119 Cat. No. J215-E1-03 0318(0316)
G70V-SOC16P-1-C4 价格&库存

很抱歉,暂时无法提供与“G70V-SOC16P-1-C4”相匹配的价格&库存,您可以联系我们找货

免费人工找货
G70V-SOC16P-1-C4
  •  国内价格 香港价格
  • 1+7255.884341+943.46479

库存:0