9
SYSMAC Transistor Remote Module
G72C
Terminal Block and Transmission
Capability in One Module
1 Two-conductor cable communications
available using Omron Wired Remote
I/O Master Modules (C200H-RM201
and C500-RM201)
1 Can share transmission lines with
G72C-V Remote Terminal Blocks
1 187.5 kbps communication speed with
maximum 200 m transmission distance
1 Isolated transmission lines ensure
èò
excellent noise immunity
1 Easily mounts to DIN rail track or with
screws for panel mounting
Ordering Information
Classification
For input
Internal I/O circuit common
NPN (+ common)
PNP (-- common)
For output
I/O points
16 points per
module
d l
Rated voltage
24 VDC
Part number
G72C-ID16 DC24V
G72C-ID16-1 DC24V
NPN (-- common)
G72C-OD16 DC24V
PNP (-- common)
G72C-OD16-1 DC24V
Specifications
3 RATINGS
G72C-ID16-1 Input
Rated input voltage
24 VDC
Input current
9.7 mA/point
ON delay time
1.5 ms max.
OFF delay time
1.5 ms max.
Number of circuits
16 points (8 points/common)
ON voltage
15 VDC max.
OFF voltage
5.6 VDC max.
Insulation method
Photocoupler
Input indication
LEDs (green)
G72C
G72C
G72C-OD16-1 Output
Rated input voltage
24 VDC
Rated output current
0.3 A/point
Residual voltage
1.2 V max.
Leakage current
100 µA max.
Number of circuits
16 points (8 points/common)
Insulation method
Photocoupler
Input indication
LEDs (green)
3 CHARACTERISTICS
Communication system
Two-conductor, half duplex
Synchronization method
Asynchronous
Transmission speed (baud rate)
187.5 kbps (transmission time: 2 ms max. per G72C)
Transmission distance
200 m (total length)
Transmission path
Two-conductor cable (VCTF 0.75 x DPDT recommended)
Interface
RS-485
Operating voltage range
24 VDC +10%/ --15%
Current consumption (See Note)
24 VDC: 200 mA max.
RUN output
SPST-NO contact output (closed during operation)
Contact capacity: 100,000 operations at 2 A, 250 VAC (cosφ = 1)
Diagnostics
Transmission error check (BCC plus inverted two-transmission verification check),
CPU error monitor
20 MΩ min. at 250 VDC
Insulation resistance
Dielectric strength
2,000 VAC, 50/60 Hz for 1 min between RUN output circuit and other terminals
500 VAC, 50/60 Hz for 1 min for other terminals
Noise immunity
Noise level: 1.5 kV; pulse width: 100 ns to 1 Ps
Vibration resistance
10 to 55 Hz, 0.75--mm double amplitude for 2 hrs each in X, Y, and Z directions (both mounted
and not mounted to DIN track)
Shock resistance
Ambient temperature
50G, 3 times each in X, Y, and Z directions
Operating: 0°C to 55°C (32°F to 131°F)
Storage: --20°C to 65°C (--4°F to 149°F)
Ambient humidity
Operating: 35% to 85%
Mounting strength
No damage when 5 kgf (4.9 N) pull load was applied for 1 s in all directions
(except for 1 kgf (0.9 N) in direction of rail)
Terminal strength
No abnormality when 5 kgf (4.9 N) pull load was applied for 1 s in all directions
Weight
Approx. 380 g
Approvals
UL recognized, File No. E41515; CSA certified, File No. LD31928 for G72C-ID16, G72C-OD16
Note: Consumption when all 16 points are ON. Excludes external current for Remote Input Terminal and external load current for Remote Output Terminal. Maximum current consumption for both input and output when all points are OFF will be 40 mA at 24 VDC.
2
G72C
G72C
Nomenclature
Transmission
Power
Path Terminals Terminals
Indicates Remote Terminal for input.
(Out indicates Remote Terminal for output.)
Label
Indicators
Power &
Transmission
Error
I/O LEDs
I/O Terminals
RUN Output
Indicates negative side terminal
Rail Hook
3 INDICATOR OPERATION
POWER
T/R ERR
Display
Meaning
Lit
Lit when power is supplied and the unit is operating.
Not lit
Not lit when power supply is abnormal.
Flashing
Flashes during normal data transmission.
Lit
Lit during standby and transmission error.
Not lit
Not lit during CPU (watchdog timer) error.
3
G72C
G72C
Operation
3 SETTING
Output HOLD/STOP Mode
Word Settings
Terminator Setting
OFF
ON
Not terminator
(termination resistance
OFF)
Terminator
(termination resistance
ON)
The terminator setting also sets the termination
resistance. Be sure to set only one terminator
per Remote I/O Master Unit and be sure it is
the Unit farthest from the Master (Factory-set
to OFF.)
Set word numbers in order backwards from 31.
(Factory set to 31.)
Output HOLD/STOP Mode
(for Remote Output Interface only)
Pin 6
HOLD
STOP
OUT channel status is held during a slave transmission error.
All OUT channel bits go OFF for a slave transmission error.
(See Note)
Note: A slave transmission error results if no data or abnormal data is sent from the Master Unit. (Factory-set to STOP mode.)
Word Settings
Word
Pin
1
2
3
4
5
0
OFF
OFF
OFF
OFF
OFF
1
ON
OFF
OFF
OFF
OFF
2
OFF
ON
OFF
OFF
OFF
3
ON
ON
OFF
OFF
OFF
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
28
OFF
OFF
ON
ON
ON
29
ON
OFF
ON
ON
ON
30
OFF
ON
ON
ON
ON
31
ON
ON
ON
ON
ON
4
G72C
G72C
3 SYSTEM CONFIGURATION
CPU Rack
Two-conductor
cable
Wired Remote I/O Master Module (C500-RM201 or C200H-RM201)
Two-conductor cable
G71 Remote
Interface
G7TC I/O Block
G72C Remote Terminal
Dimensions
Unit: mm (inch)
182 (7.17) max.
170±0.2
Two, 5 dia. holes (for M4 screws)
85
(3.35)
max.
75±0.2
35.3±0.2
M3.5
8
10
35 max.
45 (1.77)
max.
5
G72C
G72C
Installation
3 INTERNAL CIRCUITS
G72C-ID16 for Input
G72C-OD16 for Output
Relay contacts
A
B
Relay contacts
A
B
A0
B0 (+)
A0
B1 (--)
Photocoupler
B2 (+)
--1
Fuse
+2
B0 (+)
4.3 kΩ
A1
DC/DC
converter
B3 (--)
--3
G72C-ID16-1 for Input
Internal circuit
+0
Photocoupler
RUN
output
Power supply Transmission path
Internal circuit
Power supply Transmission path
Photocoupler
RUN
output
+0
B1 (--)
Photocoupler
B2 (+)
4.3 kΩ
--1
A1
Fuse
+2
DC/DC
converter
B3 (--)
--3
G72C-OD16-1 for Output
A
B
PHC
A
B
B0 (+)
A0
B1 (--)
B2 (+)
PHC
--1
A1
+2
B3 (--)
DC/DC
converter
--3
Internal circuit
+0
A0
Power supply Transmission path
Internal circuit
Power supply Transmission path
PHC
B0 (+)
+0
B1 (--)
PHC
B2 (+)
--1
A1
+2
DC/DC
converter
B3 (--)
--3
3 TERMINAL ARRANGEMENT
Transmission path
+
--
0
1
Power supply
+
A
A0
B
Black marks
6
A1
B0
A2
B1
A3
B2
A4
B3
A5
B4
A6 A7 A8
B5
-2
3
A9 A10 A11 A12 A13 A14 A15
B6 B7 B8
B9 B10 B11 B12 B13 B14 B15
Note: Positive power terminal no. 2 at the upper-right part is internally connected to the B0, B2, B4, B6, B8, B10, B12, and B14 I/O
terminals at the lower part, and negative power terminal no. 3
at the upper-right part is internally connected to the B1, B3, B5,
B7, B9, B11, B13, and B15 I/O terminals at the lower part and
have black marks.
G72C
G72C
3 CONNECTION WITH I/O DEVICES
(Repeater terminal block for sensor/load power wiring is not required.)
Proximity sensor
Photoelectric sensor
For Input
Sensor 1
Sensor 2
A1
+
B0
A2
--
Sensor 1
IN
+
B1
A0
B2
A1
+
B0
Sensor 2
Sensor 1
--
A2
+
B1
IN
B2
White
A0
B;acl
IN
Black
+
B2
Red
White
Black
B1
Red
White
Black
B0
A2
Two-wire Connection
G72C-ID16-1
Black
--
White
A1
Black
+
White
A0
Two-wire Connection
G72C-ID16
White
Three-wire Connection
Sensor 2
For Output
G72C-OD16
A0
+
B0
L1
A1
G72C-OD16-1
-B1
L2
A2
+
OUT
A0
+
B0
B2
L1
A1
-B1
A2
+
OUT
B2
L2
7
G72C
G72C
Precautions
3 PROPER APPLICATION
Each node can consist of either a G72C Remote Terminal or a
G71 Remote Interface and G7TC I/O Block pair.
Each Remote I/O Subsystem connected to a Master Module can
contain up to 32 nodes.
Never connect or disconnect a G71 Remote Interface without first
turning off the power. Failure to turn off the power can result in
operational errors.
Be sure to supply the correct power to each Remote Module and
combine only compatible units.
I/O specifications are provided in the following. Proper
combinations can be checked with label colors.
The G71 Remote Output Interface corresponds to NPN
(-- common). Use the NPN-output G7TC Models (+ common)
when connecting.
Always confirm that all G71 and G72C Units have been turned on
before turning providing power to the Master.
All Remote Modules are available as 24 VDC Input or 24 VDC
Output models.
G71 Remote Interface
Item
Model
Label color
G7TC I/O Block
Model
G72C Remote Terminal
Label display
(color)
Model
Label color
Input
G71-IC16
Red
G7TC-IA16
G7TC-ID16
IA16 (red)
G72C-ID16
Red
Output
G71-OD16
Yellow
G7TC-OC16
G7TC-OC08
OS16/OS08 (yellow)
G72C-OD16
Yellow
Note: Do not connect a G71 Remote Interface to a G7TC-OC16-1 I/O Block, which is a PNP model (-- common); they are incompatible.
Connections
Correct Example
Incorrect Example 1
Incorrect Example 2
Always wire in order from the Master,
connecting positive to positive and negative to negative, without branching.
The wiring below is incorrect
because positive has been
connected to negative.
The wiring below is incorrect because
a branch has been created.
Remote I/O
Master
C500-RM201
C200H-RM201
8
G71 Remote
Interface
G72C Remote
Terminal
G71 Remote
Interface
G72C Remote
Terminal
Remote I/O
Master
C500-RM201
C200H-RM201
G71 Remote
Interface
G72C Remote
Terminal
Remote I/O
Master
C500-RM201
C200H-RM201
G71 Remote
Interface
G72C Remote
Terminal
G71 Remote
Interface
G72C Remote
Terminal
G72C
G72C
NOTE: DIMENSIONS SHOWN ARE IN MILLIMETERS. To convert millimeters to inches divide by 25.4.
9
OMRON ELECTRONICS, INC.
OMRON CANADA, INC.
One East Commerce Drive
Schaumburg, IL 60173
885 Milner Avenue
Scarborough, Ontario M1B 5V8
1-800-55-OMRON
416-286-6465
Cat. No. GC RIO-1
04/00
Specifications subject to change without notice.
Printed in U.S.A.