G7L
Power Relay
A High-capacity,
High-dielectric-strength Relay
Compatible with Momentary
Voltage Drops
• No contact chattering for momentary voltage drops up to 50% of
rated voltage.
• Wide-range AC-activated coil that handles 100 to 120 or 200 to
240 VAC at either 50 or 60 Hz.
• Miniature size for maximum switching power, particularly for
inductive loads.
• Flame-resistance materials (UL94V-0-qualifying) used for all
insulation material.
• Quick-connect, screw, and PCB terminals, and DIN track
mounting available.
• Conforms to UL, CSA, TUV and meets IEC950.
• Safety design with contact gap of 3 mm.
Note. Accessories: E-bracket, Adapter, Front-connecting socket
and Cover sold separately.
G
7
L
RoHS Compliant
■Application Examples
■Model Number Legend
G 7 L -@ @ -@ @ @
—— ———
1 2
3 4 5
1. Number of Poles
1: 1 pole
2: 2 poles
2. Contact Form
A: @PST-NO
3. Terminal Shape
T: Quick connect
terminals (#250)
B: Screw terminals
P: PCB terminals
4. Mounting Construction
Blank: E-bracket
UB : Upper bracket
5. Special Functions
J : With test button
■Model Configuration
Terminal
Classification
E-bracket
mounting
(E-bracket is
sold separately)
Upper bracket
mounting
−
With test
button
−
With test
button
PCB mounting
−
Contact form
SPST-NO
DPST-NO
SPST-NO
DPST-NO
SPST-NO
DPST-NO
SPST-NO
DPST-NO
SPST-NO
DPST-NO
Quick-connect
terminals
G7L-1A-T
G7L-2A-T
G7L-1A-TJ
G7L-2A-TJ
G7L-1A-TUB
G7L-2A-TUB
G7L-1A-TUBJ
G7L-2A-TUBJ
−
−
Screw terminals
G7L-1A-B
G7L-2A-B
G7L-1A-BJ
G7L-2A-BJ
G7L-1A-BUB
G7L-2A-BUB
G7L-1A-BUBJ
G7L-2A-BUBJ
−
−
PCB terminals
Compressors for air conditioners
and heater switching controllers.
Switching controllers for power tools
or motors.
Power controllers for water heaters.
Power controllers for dryers.
Lamp controls, motor drivers, and
power supply switching in copy
machines, facsimile machines, and
other office equipment.
Lighting controllers.
Power controllers for packers or
food processing equipment.
Magnetron control in microwaves.
Power controllers for Uninterruptible
Power Supply (UPS)
−
−
−
−
−
−
−
−
G7L-1A-P
G7L-2A-P
■List of E-bracket Mounting Models
Mounting E-brackets
Terminal
Quickconnect
terminals
Screw
terminals
Contact
form
SPST-NO
DPST-NO
SPST-NO
DPST-NO
Model
G7L-1A-T
G7L-1A-TJ
G7L-2A-T
G7L-2A-TJ
G7L-1A-B
G7L-1A-BJ
G7L-2A-B
G7L-2A-BJ
Test button
−
With test button
−
With test button
−
With test button
−
With test button
DIN Track
Mounting
Adapter
Front-connecting
Socket
−
−
−
−
Note. Accessories: E-bracket (R99-07), Adapter (P7LF-D),
Front-connecting socket (P7LF-06) and Cover
(P7LF-C) sold separately.
1
G7L
Power Relay
■Ordering Information
E-bracket/Adapter/Socket Mounting
E-bracket/Adapter/Socket Mounting (with test button)
Quick-connect Terminal
Number
of poles
Model
1 pole
G7L-1A-T
2 poles
G7L-2A-T
Quick-connect Terminal
Rated coil voltage
Minimum
packing unit
AC: 12, 24, 100/120, 200/240
DC: 6, 12, 24, 48, 100
AC: 12, 24, 50, 100/120, 200/240
DC: 6, 12, 24, 48, 100
1 pole
G7L-1A-TUB
2 poles
G
7
L
G7L-2A-TUB
1 pole
G7L-1A-TJ
2 poles
G7L-2A-TJ
Rated coil voltage
AC: 24, 100/120, 200/240
DC: 12, 24, 48, 100
AC: 24, 100/120, 200/240
Quick-connect Terminal
Rated coil voltage
Minimum
packing unit
AC: 12, 24, 100/120, 200/240
DC: 6, 12, 24, 48, 100
AC: 12, 24, 50, 100/120, 200/240
Number
of poles
Model
1 pole
G7L-1A-TUBJ
Rated coil voltage
20 pcs./tray
2 poles
DC: 6, 12, 24, 48, 100
G7L-2A-TUBJ
DC: 6, 12, 24, 48, 100
AC: 12, 24, 50, 100/120, 200/240
Screw Terminal
1 pole
G7L-1A-B
2 poles
G7L-2A-B
Minimum
packing unit
AC: 12, 24, 100/120, 200/240
DC: 6, 12, 24, 48, 100
AC: 12, 24, 100/120, 200/240
Number
of poles
Model
1 pole
G7L-1A-BJ
Rated coil voltage
20 pcs./tray
2 poles
DC: 12, 24, 48, 100
G7L-2A-BJ
DC: 12, 24
AC: 24, 100/120, 200/240
Upper Bracket Mounting (with test button)
Screw Terminal
1 pole
G7L-1A-BUB
2 poles
G7L-2A-BUB
Rated coil voltage
Minimum
packing unit
AC: 24, 100/120, 200/240
DC: 6, 12, 24, 48, 100
AC: 12, 24, 50, 100/120, 200/240
Model
DC: 6, 12, 24, 48, 100
1 pole
G7L-1A-P
2 poles
G7L-2A-P
Rated coil voltage
Minimum
packing unit
AC: 100/120, 200/240
DC: 12, 24, 48, 100
AC: 24, 100/120, 200/240
20 pcs./tray
DC: 6, 12, 24, 48, 100
Name
Model
Minimum
packing unit
PFP-100N
Adaptor Surface
Connection Socket
DIN Track
PFP-50N
PFP-100N2
End plate
PFP-M
Spacer
PFP-S
1 pole
G7L-1A-BUBJ
2 poles
G7L-2A-BUBJ
Rated coil voltage
Minimum
packing unit
AC: 24, 100/120, 200/240
DC: 6, 12, 24, 48
AC: 24, 100/120, 200/240
20 pcs./tray
DC: 6, 12, 24, 48, 100
Note 1. When ordering, add the rated coil voltage to the model number.
Example: G7L-1A-T AC12
Rated coil voltage
However, the notation of the coil voltage on the product case as well as
on the packing will be marked as @@ VDC.
Note 2. Refer to the precautions on PCB Relays provided in General
Information of the Relay Product Data Book, and "w -@-3" for coil
characteristics of AC operation.
E-bracket/Adaptor/Socket/Cover
DIN Track Mounting Accessories
Applicable products
Model
20 pcs./tray
PCB Mounting
Number
of poles
Number
of poles
20 pcs./tray
DC: 12, 24, 48, 100
Screw Terminal
Model
Minimum
packing unit
AC: 12, 24, 100/120, 200/240
Upper Bracket Mounting
Number
of poles
20 pcs./tray
DC: 6, 12, 24, 48, 100
E-bracket/Adapter Mounting (with test button)
Rated coil voltage
Minimum
packing unit
AC: 24, 100/120, 200/240
Screw Terminal
Model
20 pcs./tray
DC: 6, 12, 24, 48, 100
E-bracket/Adapter Mounting
Number
of poles
Minimum
packing unit
Upper Bracket Mounting (with test button)
Quick-connect Terminal
Model
Model
20 pcs./tray
Upper Bracket Mounting
Number
of poles
Number
of poles
10 pcs.
Note. Order the models above in increments of the minimum quantity packaged.
Applicable Relay
models
G7L-1A-T
G7L-1A-TJ
G7L-1A-B
G7L-1A-BJ
G7L-2A-T
G7L-2A-TJ
G7L-2A-B
G7L-2A-BJ
Name
Model
Minimum
packing unit
E-bracket
R99-07
10 pcs.
Adapter
P7LF-D
1 pcs.
G7L-1A-T
G7L-1A-TJ
G7L-2A-T
G7L-2A-TJ
Front-connecting
Socket
P7LF-06
1 pcs.
G7L-1A-B
G7L-1A-BJ
G7L-1A-BUB
G7L-1A-BUBJ
G7L-2A-B
G7L-2A-BJ
G7L-2A-BUB
G7L-2A-BUBJ
Cover
P7LF-C
1 pcs.
Note. Order the models above in increments of the minimum quantity packaged.
2
G7L
Power Relay
■Ratings
■Characteristics
Coil
Item
Rated voltage
12 VAC
24 VAC
50 VAC
100 to 120 VAC
200 to 240 VAC
6 VDC
12 VDC
24 VDC
48 VDC
100 VDC
Rated
current
(mA)
Coil inductance (H)
Coil
resistance
(Ω)
142
71
34
17.0 to 20.4
8.5 to 10.2
317
158
79
40
19
Max.
Must operate Must release
permissible
Power
voltage
voltage
voltage consumption
(VA-W)
On the basis of rated voltage
Armature
ON
18.9
75
303
1220
5260
Armature
OFF
0.09
0.37
1.42
6.1
21.3
0.21
0.88
3.54
15.3
60.0
75% max.
15% min.
110%
75 V max.
150 V max.
18 V min.
36 V min.
132 V
264 V
75% max.
15% min.
110%
Approx. 1.7
to 2.5
Approx. 1.9
Contact resistance *1
Operate time *2
Release time *3
Max.
Mechanical
operating
frequency Rated load
50 mΩ max.
30 ms max.
30 ms max.
Insulation resistance *3
Between coil and
contacts
Between contacts
Dielectric
of same polarity
strength
Between contacts
of different polarity
(DPST-NO model)
1,000 MΩ min
4,000 VAC min., 50/60 Hz
for 1 min
1,800 operations/hr
1,800 operations/hr
10,000 V between coil and
contact *4
10 to 55 to 10 Hz, 0.75 mm
single amplitude
(1.5 mm double amplitude)
10 to 55 to 10 Hz, 0.75 mm
single amplitude
(1.5 mm double amplitude)
1,000 m/s2
100 m/s2
1,000,000 operations min.
(at 1,800 operations/hr)
100,000 operations min.
(at 1,800 operations/hr
under rated load)
Impulse withstand voltage
Note 1. The rated current and coil resistance are measured at a coil temperature of 23°C with tolerances of
+15%/-20% for AC rated current and ±15% for DC coil resistance.
2. The inductances shown above are reference values.
3. Performance characteristic data are measured at a coil temperature of 23°C.
4. The maximum allowable coil voltage refers to the maximum value in a varying range of operating power
voltage, measured at ambient temperature 23°C.
5. The "to" (for example "100 to 120") represents the range of rated voltages.
Vibration
resistance
Shock
resistance
Destruction
Malfunction
Destruction
Malfunction
Mechanical
Contacts
Contact Form
G7L-1A-T@
G7L-1A-B@
load
Item
Contact type
Contact material
Rated load
Rated carry current
Max. switching
voltage
Max. switching
current
Resistive
load
G7L-2A-T@
G7L-2A-B@
Inductive load
(cosφ = 0.4)
Inductive
load
(cosφ = 0.4)
Resistive
load
G7L-1A-P
G7L-2A-P
Resistive
load
Double break
Ag alloy
25 A at 220 VAC
25 A
30 A at 220 VAC 25 A at 220 VAC
30 A
Endurance
Inductive
load
(cosφ = 0.4)
20 A at 220 VAC
20 A
250 VAC
30 A
25 A
2,000 VAC, 50/60 Hz for
1 min
Electrical *5
Failure rate (P level)
(reference value *6)
100 mA at 5 VDC
Weight
Approx. 90 g:
Quick-connect terminal
models
Approx. 100 g:
PCB terminal models
Approx. 120 g:
Screw terminal models
G
7
L
Note. The values given above are initial values.
*1.
Measurement conditions: 5 VDC, 1 A, voltage drop
method.
*2.
Measurement conditions: Rated operating voltage applied,
not including contact bounce.
Ambient temperature: 23°C
*3.
Measurement conditions: The insulation resistance was
measured with a 500-VDC megohmmeter at the same
locations as the dielectric strength was measured.
*4.
JEC-212 (1981) Standard Impulse Wave Type (1.2×50μs).
*5.
Ambient temperature: 23°C
*6.
This value was measured at a switching frequency of 60
operations/min.
20 A
Note. When using B-series (screw) products, since the screw diameter of the contact terminal is M4, be careful
that the contact current should be 20 A or less according to JET standard (electrical appliance and material
control law of Japan).
Ambient operating temperature
Ambient operating humidity
-25°C to 60°C
(with no icing or
condensation)
5% to 85%
■Engineering Data
AC resistive load
50
30
20
AC inductive load
(cosφ = 0.4)
100
AC resistive load
AC inductive load
(cosφ = 0.4)
50
30
20
Ambient Temperature vs. Operate
and Release Voltage
G7L-1A VAC (60 Hz)
50
AC resistive load
AC inductive load
(cosφ = 0.4)
30
20
10
10
10
7
7
7
5
5
5
Operate and Release voltages (%)
100
G7L-1A-P
G7L-2A-P
Maximum Switching Power
Switching current (A)
G7L-2A-T (TJ) (TUB) (TUBJ)
G7L-2A-B (BJ) (BUB) (BUBJ)
Maximum Switching Power
Switching current (A)
Switching current (A)
G7L-1A-T (TJ) (TUB) (TUBJ)
G7L-1A-B (BJ) (BUB) (BUBJ)
Maximum Switching Power
100
Operate voltage
Release voltage
80
60
40
3
3
3
20
1
50 70 100
30
300 500 1,000
1
10
30
50 70 100
Switching voltage (V)
Endurance
Endurance (x 104 operations)
Endurance (x 104 operations)
Endurance
500
300
100
300 500 1,000
220 VAC resistive load
70
50
30
220 VAC
inductive load
(cosφ = 0.4)
300
100
220 VAC resistive load
70
50
220 VAC
inductive load
(cosφ = 0.4)
5
10
15
20
25
30
Switching current (A)
0
-40
300 500
5
10
15
20
25
30
Switching current (A)
0
20
300
100
70
50
220 VAC resistive load
220 VAC
inductive load
(cosφ = 0.4)
0
5
40
60
80
Ambient temperature (°C)
G7L-1A VDC
500
7
5
0
-20
Switching voltage (V)
10
7
5
0
50 70 100
30
10
7
5
30
Endurance
500
30
10
10
Ambient temperature (°C)
Endurance (x 104 operations)
10
Operate and Release voltages (%)
1
10
100
Operate voltage
Release voltage
80
60
40
20
15
20
25
30
Switching current (A)
0
-40
-20
0
20
40
60
80
Ambient temperature (°C)
3
G7L
Power Relay
80
N=5
Shock Malfunction
G7L-2A-T (TUB) 100 to 120 VAC
G7L-1A VDC
Coil Temperature Rise (°C)
Coil Temperature Rise (°C)
Ambient Temperature vs.
Coil Temperature Rise
G7L-1A 120 VAC (50 Hz)
30 A
15 A
0A
60
40
80
N=5
Y
30 A
15 A
0A
400
50
60
0
300
X
40
0
30
0
200
20
0
10
40
0
10
20
40
Test method: The value at which
malfunction occurred
was measured after
applying shock to the
test piece 3 times
Z'
each in 6 directions
0
50
along 3 axes.
Standard:
100m/s2
20
100
100
200
40
20
30
0
0
10
0
0
30
0
0
100
0
0
20
N=5
500
X
300
200
0
50
Z
400
300
500
X'
Y
X'
Z
Z'
400
0
-40
-20
0
20
40
60
0
-40
80
-20
0
20
Ambient temperature (°C)
40
60
80
500
Ambient temperature (°C)
Momentary Voltage Drop Test
G7L-2A-T (TUB) 100 to 120 VAC
Test Circuit
Wave resulted from test
Y'
Shock direction
Y'
Number of Relays
Voltage distribution of wave e which
chattering does not occur.
ON
Without chattering
Ch1
(contact)
Unit: (m/s2)
OFF
8
n=10
6
4
Rated
Ch2 voltage
(coil)
Ch1
G
7
L
e
2
Ch2
0
20
40
60
80
100
On the basis of rated voltage (%)
20
35
N=5
30
Operate time
Release time
15
25
10
20
5
15
0
Top
A
Bottom (Standard)
A'
B
B'
(Note)
C
0
C'
Release voltage
N=5
70
Operate voltage
60
50
Top
A
A'
B
B'
C
(Note)
0
C'
Top
A
A'
Bottom(Standard)
Mounting direction
50
N=5
40
30
Release voltage
20
10
40
Bottom(Standard)
Mounting direction
80
On the basis of rated voltage (%)
N=5
On the basis of rated voltage (%)
25
Time (ms)
Time (ms)
Characteristic variation resulted from different mounting directions
G7L-2A-T (TUB) 100 to 120 VAC
Operate time
Release time
Operate voltage
B
B'
(Note)
C
0
C'
Top
A
Bottom(Standard)
Mounting direction
A'
B
B'
C
(Note)
C'
Mounting direction
(Note.)The mounting direction A’ deteriorates switching performance.
60
Operate voltage
50
40
30
N=5
80
60
40
Release voltage
20
70
Operate
voltage
N=5
60
50
40
30
Contact resistance
Contact resistance (mΩ)
100
N=5
On the basis of rated voltage (%)
70
Operate and Release voltages
N=5
Contact resistance
Contact resistance (mΩ)
On the basis of rated voltage (%)
Actual Load Endurance Test
G7L-2A 100 to 200 VAC
Operate and Release voltages
N=5
50
N=5
40
30
20
Release
voltage
20
20
10
10
10
0
0.5 0.7 1
3
5
7
10
30
50
Switching operations (×104 operations)
0
0.5 0.7 1
3
5
7
10
30
50
0
0.05 0.07 0.1
Switching operations (×104 operations)
Load conditions
• 1 φ 220 VAC
0.3
0.5
1
3
5
Switching operations (×104 operations)
0
0.05 0.07 0.1
0.3
0.5
1
3
Load conditions
• 1 φ 220 VAC
70 A cosφ = 0.4
54 A cosφ = 0.79
(Compressor Lock Test)
20 A cosφ = 0.4
0.2s
1s
4
1s
• Applied coil voltage: 100% of rated
voltage
0.5s
10s
5
Switching operations (×104 operations)
• Applied coil voltage: 100% of rated
voltage
G7L
Power Relay
Operate voltage
60
50
40
50
N=5
40
30
Release voltage
30
20
20
70
N=5
Operate voltage
60
Contact resistance
Contact resistance (mΩ)
N=5
On the basis of rated voltage (%)
70
Operate and Release voltages
N=5
Contact resistance
Contact resistance (mΩ)
On the basis of rated voltage (%)
G7L-2A 100 to 200 VAC
Operate and Release voltages
N=5
50
40
50
N=5
40
30
Release voltage
30
20
20
10
10
10
10
0
0.5 0.7 1
3
5
10
30
0
0.5 0.7 1
50
Switching operations (×102 operations)
3
5
10
30
0
0.5 0.7 1
50
3
Switching operations (×102 operations)
5
10
30
0
0.5 0.7 1
50
Switching operations (×102 operations)
Load conditions
• 1 φ 220 VAC
3
5
10
30
50
Switching operations (×102 operations)
Load conditions
• 1 φ 220 VAC
70 A cosφ = 0.4
20 A cosφ = 0.4
25 A cosφ = 1
2s
• Applied coil voltage: 75% of rated
voltage
8s
• Applied coil voltage: 75% of rated
voltage
0.2s
2s
8s
■Dimensions
● E-bracket Mounting
Quick-connect Terminals
G
7
L
Note. E-brackets are sold separately.
G7L-1A-T
Terminal Arrangement/
Internal Connections
(Top View)
52.5 max.
6.35
50.5 max.
33.5 max.
0.8
11
0
53 max.
1
4
6
(No coil polarity)
Note. Refer to page 12 for the coil internal
connection diagram
G7L-2A-T
6.35
52.5 max.
50.5 max.
33.5 max.
0.8
11
0
2
53 max.
1
4
6
8
(No coil polarity)
Note. Refer to page 12 for the coil internal
connection diagram
G7L-1A-TJ
(with Test Button)
6.35
52.5 max.
50.5 max.
33.5 max.
Mounting Holes
Two, 4.5-dia. hole or
M4 tapped holes
2
0.8
Test
button
11
40±0.1
0
1
4
53 max.
6
(No coil polarity)
Note. Refer to page 12 for the coil internal
connection diagram
G7L-2A-TJ
(with Test Button)
6.35
52.5 max.
50.5 max.
33.5 max.
2
0.8
11
Test
button
53 max.
0
2
1
4
6
8
(No coil polarity)
Note. Refer to page 12 for the coil internal
connection diagram
5
G7L
Power Relay
● Adapter Mounting
Quick-connect Terminals
Note 1. The DIN Track Mounting Adapter and DIN tracks are sold separately.
2. The DIN Track Mounting Adapter can be track-mounted or screw-mounted.
G7L-1A-T
Terminal Arrangement/
Internal Connections
(Top View)
P7LF-D
PFP-@N
G7L
0
1
51.5 max.
4
55.5 max.
63 max.
5
66.5 max.
G7L-2A-T
6
(No coil polarity)
Note. Refer to page 12 for the coil internal
connection diagram
P7LF-D
PFP-@N
G7L
0
1
51.5 max.
2
4
6
8
Mounting Holes
63 max.
55.5 max.
5
66.5 max.
G G7L-1A-TJ
7 (with Test Button)
L
(No coil polarity)
Note. Refer to page 12 for the coil internal
connection diagram
40±0.1
P7LF-D
PFP-@N
Two, M4 or 4.5-dia.
holes
G7L
0
1
51.5 max.
4
2
Test button
63 max.
55.5 max.
5
66.5 max.
G7L-2A-TJ
(with Test Button)
6
(No coil polarity)
Note. Refer to page 12 for the coil internal
connection diagram
P7LF-D
PFP-@N
G7L
0
1
51.5 max.
2
2
55.5 max.
Test button
63 max.
5
66.5 max.
● Front-connecting Socket Mounting
Quick-connect Terminals
6
8
(No coil polarity)
Note. Refer to page 12 for the coil internal
connection diagram
Note 1. The Front-connecting Socket and DIN tracks are sold separately.
2. The Front-connecting Socket can be track-mounted or screw-mounted.
G7L-1A-T
PFP-@N
4
2-M3.5 × 6 (coil side)
Terminal Arrangement/
Internal Connections
(Top View)
P7LF-06
G7L
0
1
51.5 max.
4
55.5 max.
61.5 max.
65 max.
4-M4 × 8 (contact side)
G7L-2A-T
PFP-@N
2-M3.5 × 6 (coil side)
5
Mounting Holes
6
(No coil polarity)
Note. Refer to page 12 for the coil internal
connection diagram
40±0.1
P7LF-06
G7L
0
1
51.5 max.
2
55.5 max.
4-M4 × 8 (contact side)
6
61.5 max.
65 max.
Two, M4 or 4.5-dia.
holes
5
4
6
8
(No coil polarity)
Note. Refer to page 12 for the coil internal
connection diagram
G7L
Power Relay
G7L-1A-TJ
(with Test Button)
2-M3.5 × 6 (coil side)
PFP-@N
Terminal Arrangement/
Internal Connections
(Top View)
P7LF-06
G7L
0
1
51.5 max.
4
2
55.5 max.
Test button
61.5 max.
G7L-2A-TJ
(with Test Button)
PFP-@N
2-M3.5 × 6 (coil side)
5
65 max.
4-M4 × 8 (contact side)
6
Mounting Holes
(No coil polarity)
Note. Refer to page 12 for the coil internal
connection diagram
Two, M4 or 4.5-dia.
holes
40±0.1
P7LF-06
G7L
0
1
51.5 max.
2
2
Test button
61.5 max.
55.5 max.
4-M4 × 8 (contact side)
5
65 max.
4
6
8
(No coil polarity)
Note. Refer to page 12 for the coil internal
connection diagram
● Upper Bracket Mounting
Quick-connect Terminals
G7L-1A-TUB
G
7
L
68.5 max.
Terminal Arrangement/
Internal Connections
(Top View)
60
6.35
50.5 max.
33.5 max.
0.8
11
0
1
47 max.
4
(No coil polarity)
Note. Refer to page 12 for the coil internal
connection diagram
4.5
G7L-2A-TUB
6
68.5 max.
60
6.35
50.5 max.
33.5 max.
0.8
11
0
47 max.
2
4
6
8
(No coil polarity)
Note. Refer to page 12 for the coil internal
connection diagram
2.5
4.5
G7L-1A-TUBJ
(with Test Button)
1
Mounting Holes
Two, 4.5-dia. hole or
M4 tapped holes
68.5 max.
60
6.35
50.5 max.
33.5 max.
60±0.2
2
0.8
11
Test
button
0
47 max.
4
6
(No coil polarity)
Note. Refer to page 12 for the coil internal
connection diagram
2.5
4.5
G7L-2A-TUBJ
(with Test Button)
1
68.5 max.
60
6.35
50.5 max.
33.5 max.
2
0.8
Test
button
11
47 max.
2.5
4.5
0
2
1
4
6
8
(No coil polarity)
Note. Refer to page 12 for the coil internal
connection diagram
7
G7L
Power Relay
● E-bracket Mounting
Screw Terminals
Note. E-brackets are sold separately.
G7L-1A-B
2-M3.5 × 6
(coil side)
52.5 max.
50.5 max.
34.5 max.
Terminal Arrangement/
Internal Connections
(Top View)
2-M4 × 8
(contact side)
0
1
55 max.
4
6
(No coil polarity)
Note. Refer to page 12 for the coil internal
connection diagram
G7L-2A-B
52.5 max.
2-M3.5 × 6
(coil side)
50.5 max.
34.5 max.
4-M4 × 8
(contact side)
0
1
55 max.
2
4
6
Mounting Holes
8
(No coil polarity)
Note. Refer to page 12 for the coil internal
connection diagram
G7L-1A-BJ
(with Test Button)
G
7
L
2-M3.5 × 6
(coil side)
52.5 max.
50.5 max.
34.5 max.
2-M4 × 8
2 (contact side)
Two, 4.5-dia. hole or
M4 tapped holes
40±0.1
Test
button
0
1
55 max.
4
6
(No coil polarity)
Note. Refer to page 12 for the coil internal
connection diagram
G7L-2A-BJ
(with Test Button)
2-M3.5 × 6
(coil side)
52.5 max.
50.5 max.
34.5 max.
4-M4 × 8
2 (contact side)
Test
button
0
1
55 max.
2
4
6
8
(No coil polarity)
Note. Refer to page 12 for the coil internal
connection diagram
● Adapter Mounting
Screw Terminals
Note 1. The DIN Track Mounting Adapter and DIN tracks are sold separately.
2. The DIN Track Mounting Adapter can be track-mounted or screw-mounted.
G7L-1A-B
PFP-@N
Terminal Arrangement/
Internal Connections
(Top View)
P7LF-D
2-M3.5 × 6 (coil side)
G7L
0
1
51.5 max.
4
6
Mounting Holes
55.5 max.
2-M4 × 8 (contact side)
G7L-2A-B
PFP-@N
2-M3.5 × 6 (coil side)
65.5 max.
5
69 max.
(No coil polarity)
Note. Refer to page 12 for the coil
internal connection diagram
40±0.1
P7LF-D
G7L
0
1
51.5 max.
2
55.5 max.
4-M4 × 8 (contact side)
8
65.5 max.
69 max.
Two, M4 or 4.5-dia.
holes
5
4
6
8
(No coil polarity)
Note. Refer to page 12 for the coil
internal connection diagram
G7L
G7L-1A-BJ
(with Test Button)
Power Relay
PFP-@N
Terminal Arrangement/
Internal Connections
(Top View)
P7LF-D
2-M3.5 × 6 (coil side)
G7L
0
1
51.5 max.
4
2
55.5 max.
65.5 max.
2-M4 × 8 (contact side)
G7L-2A-BJ
(with Test Button)
Test button
5
69 max.
6
Mounting Holes
(No coil polarity)
Note. Refer to page 12 for the coil internal
connection diagram
Two, M4 or 4.5-dia.
holes
40±0.1
PFP-@N
2-M3.5 × 6 (coil side)
P7LF-D
G7L
0
1
51.5 max.
2
2
55.5 max.
Test button
65.5 max.
4-M4 × 8 (contact side)
5
69 max.
4
6
8
(No coil polarity)
Note. Refer to page 12 for the coil internal
connection diagram
● Upper Bracket Mounting
Screw Terminals
G7L-1A-BUB
2-M3.5 × 6
(coil side)
Terminal Arrangement/
Internal Connections
(Top View)
60
50.5 max.
2-M4 × 8
(contact side)
34.5 max.
0
49 max.
1
4
2.5
G7L-2A-BUB
6
(No coil polarity)
Note. Refer to page 12 for the coil internal
connection diagram
4.5
68.5 max.
2-M3.5 × 6
(coil side)
60
50.5 max.
4-M4 × 8
(contact side)
34.5 max.
0
49 max.
2.5
1
Mounting Holes
2
4
6
8
(No coil polarity)
Note. Refer to page 12 for the coil internal
connection diagram
4.5
G7L-1A-BUBJ
(with Test Button)
G
7
L
68.5 max.
Two, 4.5-dia. hole or
M4 tapped holes
68.5 max.
2-M3.5 × 6
(coil side)
60
50.5 max.
34.5 max.
2
60±0.2
2-M4 × 8
(contact side)
Test
button
0
49 max.
1
4
2.5
4.5
G7L-2A-BUBJ
(with Test Button)
6
(No coil polarity)
Note. Refer to page 12 for the coil internal
connection diagram
68.5 max.
2-M3.5 × 6
(coil side)
60
50.5 max.
34.5 max.
2
4-M4 × 8
(contact side)
Test
button
0
1
49 max.
2
2.5
4.5
4
6
8
(No coil polarity)
Note. Refer to page 12 for the coil internal
connection diagram
9
G7L
Power Relay
● PCB Mounting
PCB Terminals
G7L-1A-P
2.8
PCB Mounting Holes
(Bottom View)
Tolerance: ±0.1 mm
Terminal Arrangement/
Internal Connections
(Bottom View)
35.5 max.
52.5 max.
0.8
6
36.8
0
1
3.2
47 max.
41 max.
(8.4)
4
6
1.2
(No coil polarity)
Note. Refer to page 12 for the coil internal
connection diagram
G7L-2A-P
2.8
52.5 max.
0.8
6
17.7
(8.9)
4-1.2 × 3.2 square hole
PCB Mounting Holes
(Bottom View)
Tolerance: ±0.1 mm
Terminal Arrangement/
Internal Connections
(Bottom View)
35.5 max.
14.4
36.8
0
1
47 max.
41 max.
(8.4)
2
4
6
8
(No coil polarity)
Note. Refer to page 12 for the coil internal
connection diagram
G
7
L
● E-bracket
R99-07 (E KANAGU)
FOR G7L
3.2
1.2
14.4
17.7
(8.9)
6-1.2 × 3.2 square hole
40
Mounting Holes
Two, 4.5-dia. hole
26
24
Two, M4 or 4.5-dia.
holes
17.8
40
10
46
3
24
19.7
7
5
30
5
4.4
50
● Adapter
P7LF-D
Mounting Holes
51.5 max.
Two, M4 or 4.5-dia.
holes
40±0.1
40±0.1
14.5
● Front-connecting
Socket
P7LF-06
2-M3.5 × 6 (coil side)
5
35.2 max.
55.5 max.
8±0.05
Mounting Holes
51.5 max.
Two, M4 or 4.5-dia.
holes
40±0.1
4-M4 × 8
(contact side)
9.2±0.05
25
5
46 max.
40±0.1
55.5 max.
● Cover
P7LF-C
34.5 max.
50.5 max.
1
6 max.
10
Put the P7LF-C cover onto the terminals in order to protect the
user from electric shock.
G7L
Power Relay
Approved Standards
A variety of Safety Standard approved products for standard models.
EN/IEC, TÜV Certified
UL Recognized
(File No. E41643)
Model
G7L-1A-T@
G7L-1A-B@
G7L-1A-P
G7L-2A-T@
G7L-2A-B@
G7L-2A-P
Coil ratings
12 to 240 VAC
6 to 220 VDC
CSA certified
Model
G7L-1A-P
30 A, 277 VAC (RES) 40°C
1.5 kW, 120 VAC (T) 40°C
1.5 HP, 120 VAC 40°C
3 HP 277 VAC 40°C
20 FLA/120 LRA, 120 VAC 40°C
17 FLA/102 LRA, 277 VAC 40°C
TV-10, 120 VAC 40°C
Model
Contact ratings
6, 12, 24, 48,
100, 110, 200,
220 VDC
12, 24, 50,
100 to 120,
200 to 240
VAC
SPST-NO (1a)
30 A, 250 VAC ~ (cosφ = 1) 60°C
25 A, 250 VAC ~ (cosφ = 0.4) 60°C
30 A, 120 VAC ~ (cosφ = 0.4) 60°C
DPST-NO (2a)
25 A, 277 VAC ~ (cosφ = 1) 60°C
25 A, 277 VAC ~ (cosφ = 0.4) 60°C
SPST-NO (1a)
25 A, 240 VAC ~ (cosφ = 1) 60°C
25 A, 240 VAC ~ (cosφ = 0.4) 60°C
25 A, 277 VAC ~ (cosφ = 1) 60°C
25 A, 277 VAC ~ (cosφ = 0.4) 60°C
DPST-NO (2a)
25 A, 240 VAC ~ (cosφ = 1) 60°C
25 A, 240 VAC ~ (cosφ = 0.4) 60°C
25 A, 277 VAC ~ (cosφ = 1) 60°C
25 A, 277 VAC ~ (cosφ = 0.4) 60°C
SPST-NO (1a)
20 A, 240 VAC ~ (cosφ = 1) 60°C
20 A, 240 VAC ~ (cosφ = 0.4) 60°C
25 A, 277 VAC ~ (cosφ = 1) 60°C
25 A, 277 VAC ~ (cosφ = 0.4) 60°C
DPST-NO (2a)
20 A, 240 VAC ~ (cosφ = 1) 60°C
20 A, 240 VAC ~ (cosφ = 0.4) 60°C
25 A, 277 VAC ~ (cosφ = 1) 60°C
25 A, 277 VAC ~ (cosφ = 0.4) 60°C
G7L-1A-B@
30,000
25,000
Coil ratings
12 to 240 VAC
6 to 220 VDC
12 to 240 VAC
6 to 220 VDC
Contact ratings
2.4 kW, 120 VAC (T) 40°C
1.5 HP, 120 VAC (T) 40°C
3 HP 277 VAC 40°C
20.5 FLA/105 LRA, 120 VAC 85°C
TV-10, 120 VAC 40°C
30 A, 277 VAC (RES) 40°C
2.4 kW, 120 VAC (T) 40°C
1.5 HP, 120 VAC 40°C
3 HP 277 VAC 40°C
20.5 FLA/105 LRA, 120 VAC 85°C
TV-10, 120 VAC 40°C
Number of test
operations
6,000
G7L-2A-B@
G7L-1A-T@
1,000
100,000
25,000
100,000
6,000
1,000
G7L-2A-T@
G7L-1A-P
100,000
25,000
●Reference
UL Approved Type ....................................................
UL508 Industrial Control Devices
UL1950 Information processing equipment
(Including office equipment)
CSA Approved Type ..................................................
CSA C22.2 No.1, 14
Industrial Control Devices
CSA C22.2 No.950 Information processing equipment
(Including office equipment)
TÜV EN/IEC Standard Approved Type......................
EN61810-1 Relay
G7L-2A-P
(Certificate No. R50059083)
Coil ratings
(File No. LR31928)
G7L-1A-T@
G7L-1A-B@
G7L-2A-T@
G7L-2A-B@
G7L-2A-P
Contact ratings
Number of test
operations
100,000
6,000
1,000
100,000
Approved
switching
operations
50,000
50,000
50,000
50,000
50,000
G
7
L
50,000
11
G7L
Power Relay
■Precautions
● Please refer to “PCB Relays Common Precautions” for general precautions.
Correct Use
● Installation
• Although there are not specific limits
on the installation site, it should be as
dry and dust-free as possible.
• Using in an atmosphere of high
temperature, high humidity and
corrosive gas may deteriorate its
performance characteristic caused by
condensation or corrosive products,
resulting in failure or burn damage of
the Relay.
• PCB Terminal-equipped Relays weigh
approximately 100 g.
Be sure that the PCB is strong enough
to support them. We recommend
dual-side through-hole PCBs to
reduce solder cracking from heat
stress.
• Relays with test buttons must be
mounted facing down.
G
Be careful not to touch the test button
7
accidentally. Doing so may turn ON
L
the contact.
• Be sure to use the test button for test
purposes only (with test-button
models). The test button is used for
Relay circuit tests, such as circuit
continuity tests. Do not attempt to
switch the load with the test button.
● Micro Loads
• The G7L is used for switching power
loads, such as motor, transformer,
solenoid, lamp, and heater loads. Do
not use the G7L for switching micro
loads, such as signals.
● Soldering PCB Terminals
• Do not perform automatic soldering
but solder manually.
• Solder with the following conditions:
Soldering iron temperature (max.)
380°C, Soldering time within 10
seconds.
• Do not wash down the entire Relay
because it does not have an airtight
construction.
● Connecting
• Refer to the following table when
connecting a wire with a crimpstyle
terminal to the G7L.
Screw terminals
Front-connecting
Socket
8
8
5.8
5
Coil
M3.5
6.5
5.3
•
M3.5
M4
M4
5.5
6.5
Contact
9.2
5.5
7
9.2
• Allow suitable slack on leads when
wiring, and do not apply excessive
force to the terminals.
• Tightening torque
Coil:
0.78 to 1.18 N . m
Contact: 0.98 to 1.37 N . m
•
•
Type
Housing
#250 terminals
(width: 6.35 mm)
Receptacle terminals
XT3W-S441-12
XT3W-S442-12
XT3W-S443-12
Note. The current should be 25 A when using receptacle terminals.
XT3B-1S white
● Reference Data
• The ratio of rated voltage between 100
to 120 VAC are values measured on
the basis of 100 VAC.
● Operating Coil
(Coil internal connections diagram)
• DC Coil
0
1
• AC Coil
0
1
• If a transistor drives the G7L check the
leakage current, and connect a
bleeder resistor if necessary.
• The AC coil is provided with a built-in
full-wave rectifier. If a triac, such as an
SSR, drives the G7L, the G7L may not
release. Be sure to perform a trial
operation with the G7L and the triac
before applying them to actual use.
12
•
When connecting with screws, if the
screws are not sufficiently tightened,
the lead wire can become detached
and may lead to abnormal heating or
fire caused by faulty contact.
Mounting Torque
0.98N . m
Tighten with two M4 screws when
mounting.
(Top bracket type)
Do not apply excessive force when
mounting or dismounting the Faston
receptacle.Insert and remove
terminals carefully one at a time. Do
not insert terminals at an angle, or
insert/remove multiple terminals at the
same time.
Do not connect to the terminals by
soldering
Refer to the following table for
recommendations of connectors
made by OMRON.
● DIN Track Mounting Adapter and
Front-connecting Socket
(DIN Track Mounting)
• The DIN Track Mounting Adapter and
Front-connecting Socket can be
mounted on the G7L with just one
hand and dismounted with ease by
using a screwdriver.
• To support the G7L mounted on a DIN
Track Mounting Adapter or
Front-connecting Socket, use the
PFP-M End Plate. Put the End Plate
onto the DIN Track Mounting Adapter
or Front-connecting Socket so that the
surface mark of the End Plate faces
upwards. Then tighten the screw of
the End Plate securely with a
screwdriver.
(Screw Mounting)
• Screw-mount the DIN Track Mounting
Adapter or Front-connecting Socket
securely after opening screw mounting
holes on them.
• When cutting or opening holes on the
panel after the Front-connecting
Socket is mounted, take proper
measures so that the cutting chips will
not fall onto the Relay terminals. When
cutting or opening holes on the upper
part of the panel, mask the
Front-connecting Socket properly with
a cover.
G7L
Power Relay
G
7
L
• Application examples provided in this document are for reference only. In actual applications, confirm equipment functions and safety before using the product.
• Consult your OMRON representative before using the product under conditions which are not described in the manual or applying the product to nuclear control systems, railroad
systems, aviation systems, vehicles, combustion systems, medical equipment, amusement machines, safety equipment, and other systems or equipment that may have a serious
influence on lives and property if used improperly. Make sure that the ratings and performance characteristics of the product provide a margin of safety for the system or
equipment, and be sure to provide the system or equipment with double safety mechanisms.
Note: Do not use this document to operate the Unit.
OMRON Corporation
Electronic and Mechanical Components Company
Contact: www.omron.com/ecb
Cat. No. J055-E1-15
0519(0207)(O)
13