0
登录后你可以
  • 下载海量资料
  • 学习在线课程
  • 观看技术视频
  • 写文章/发帖/加入社区
会员中心
创作中心
发布
  • 发文章

  • 发资料

  • 发帖

  • 提问

  • 发视频

创作活动
G7L-2A-P-PV-DC24

G7L-2A-P-PV-DC24

  • 厂商:

    OMRON(欧姆龙)

  • 封装:

    -

  • 描述:

    RELAYGENPURPOSEDPST30A24V

  • 数据手册
  • 价格&库存
G7L-2A-P-PV-DC24 数据手册
G7L-PV PCB Power Relay Two-pole Power Relay That Is Ideal for Inverters in Photovoltaic Power Systems • High switching capacity with contact rating of 30 A at 280 VAC (AC7a class). • Power consumption reduced by lowering voltage applied to coil after rated voltage is applied (low power consumption of approx. 320 mW when voltage applied to coil is reduced to 37.5%.). • Ambient operating temperature of up to 85°C. • Contact gap of 3.0 mm for safety. • UL and VDE class F certification for coil insulation. RoHS Compliant ■Model Number Legend 1. Contact Configuration 2A: DPST-NO G7L-2A-P-PV 1 2 3 2. Terminal Shape P: PCB terminals G 7 L P V 3. Relay Application PV: Photovoltaic power systems - ■Ordering Information ●PCB Terminals Number of poles 2 poles Model Rated coil voltage (V) G7L-2A-P-PV 12, 24 VDC Minimum order (Relays) 20 Relays/tray Note 1. When ordering, add the rated coil voltage to the model number. Example: G7L-2A-P-PV DC12 Rated coil voltage However, the notation of the coil voltage on the product case as well as on the packing will be marked as @@ VDC. ■Application Examples ●Grid Connection Control of Inverters for Photovoltaic Power Systems ■Ratings ●Coil Rated voltage (V) Rated current (mA) Coil resistance (Ω) Must-operate voltage Must-release voltage Maximum permissible voltage Power consumption Percentage of rated voltage DC 12 191.7 63 DC 24 95.8 250 75% max. 10% min. 110% Approx. 2.3 W Note 1. The rated current and coil resistance were measured at a coil temperature of 23°C with tolerances of ±15%. Note 2. Performance characteristics are measured at a coil temperature of 23°C. Note 3. The maximum permissible voltage is the maximum value of the fluctuation range for the Relay coil operating power supply and was measured at an ambient temperature of 23°C. ●Contacts Model Item G7L-2A-P-PV Load Resistive load Contact structure Double break Contact material Ag alloy Rated load 30 A at 280 VAC Rated carry current 30 A Maximum contact voltage 280 VAC Maximum contact current 30 A Inductive load (cosφ = 0.8) 1 G7L-PV PCB Power Relay ■Characteristics Contact resistance (See note 2.) 100 mΩ max. Operate time (See note 3.) 30 ms max. Release time (See note 3.) Maximum operating frequency 30 ms max. Mechanical 1,800 operations/h Rated load 360 operations/h Insulation resistance (See note 4.) Dielectric strength 1,000 MΩ min. Between coil and contacts 4,000 VAC, 50/60 Hz for 1 min Between contacts of the same polarity 2,000 VAC, 50/60 Hz for 1 min Between contacts of different polarity 2,000 VAC, 50/60 Hz for 1 min Impulse withstand voltage (See note 5.) Destruction Vibration resistance Shock resistance Endurance 10 to 55 to 10 Hz, 0.75-mm single amplitude (1.5-mm double amplitude) Malfunction 10 to 55 to 10 Hz, 0.75-mm single amplitude (1.5-mm double amplitude) Destruction 1,000 m/s2 Malfunction 100 m/s2 Mechanical 1,000,000 operations min. (at 1,800 operations/h) Electrical (See note 6.) 30,000 operations min. (at 360 operations/h under rated load, ON for 1 s and OFF for 9 s) Ambient operating temperature −25 to 85°C (with no icing or condensation) Ambient operating humidity 5% to 85% Failure rate (P level)(reference value) (See note 7.) 100 mA at 5 VDC Weight Approx. 100 g Note 1. The values given above are initial values. Note 2. Measurement conditions: 1 A at 5 VDC using the voltage drop method. Note 3. Measurement conditions: At rated operating voltage, not including contact bounce. Ambient temperature: 23°C Note 4. Measurement conditions: The insulation resistance was measured with a 500-VDC megohmmeter at the same places as those used for measuring the dielectric strength. Note 5. JEC-212 (1981) Standard Impulse Wave Type (1.2 × 50 μs). Note 6. Ambient temperature: 23°C Note 7. This value was measured at a switching frequency of 60 operations per minute. ■Approved Standards UL Recognized UL508, Model (File No. E41643) Coil G7L-2A-P-PV 12 VDC or 24 VDC Contact ratings 30 A 280 VAC (0.8 PF) 65°C ■Engineering Data ●Maximum Switching Power Contact current (A) - G 7 L P V 10,000 V between coil and contacts 100 AC resistive load AC inductive load (cosφ = 0.8) 50 30 20 10 7 5 3 1 10 30 50 70 100 300 500 1,000 Contact voltage (V) 2 EN/IEC and VDE Certified Number of test operations 30,000 operations Model G7L-2A-P-PV Coil 12 VDC or 24 VDC (Certificate No. 1530) Contact ratings 30 A 280 VAC (cosφ=0.8) 85°C Number of test operations 30,000 operations G7L-PV PCB Power Relay ■Dimensions (Unit: mm) G7L-2A-P-PV 2.8 52.5 max. Terminal Arrangement/Internal Connections (Bottom View) 35.5 max. 0.8 6 PCB Mounting Holes (Bottom View) Tolerance: ±0.1 mm 36.8 41 max. 47 max. 0 3.2 1 (8.4) 2 4 6 8 1.2 14.4 (The coil has no polarity.) 17.7 (8.9) Six, 1.2 × 3.2 rectangular holes ■Precautions • Refer to Safety Precautions for All PCB Relays for general precautions. Correct Use ● Installation ● Coil Voltage Reduction (Holding Voltage) after Relay Operation • If the coil voltage is reduced to the holding voltage after Relay operation, first apply the rated voltage to the coil for at least 100 ms. • A voltage of at least 37.5% of the rated voltage is required for the coil holding voltage. Do not allow voltage fluctuations to cause the coil holding voltage to fall below this level. • If you use the Relay at the holding voltage, install a diode in parallel with the coil. The G7L-PV has no coil polarity. Connect the diode so that the polarity is the opposite of the applied coil voltage. Diode Selection ● Micro Loads • The G7L-PV is a Power Relay that is suitable for grid connection switching applications for inverters in photovoltaic power systems. Do not use the G7L-PV to switch minute loads, such as signals. ● Soldering PCB Terminals • Do not perform automatic soldering. Always solder the terminals manually. • Solder with the following conditions: Soldering iron temperature (max.) 380°C, Soldering time within 10 seconds. • The G7L-PV is not sealed. Do not wash the G7L-PV with water or detergent. G7L • Dielectric strength = VRM × Rated voltage × 2 • Forward current = IF ≥ Rated current ● PCB Mounting Interval (at Rated Coil Voltage) • If you mount more than one G7L-PV, maintain the mounting intervals that are given in the following figures. • If the Relays are used with the coil voltage at the holding voltage (37.5%) at an ambient temperature of 85°C, side-byside mounting (0 mm) is possible. Relay Mounting Direction Ambient operating temperature of 85°C: 30 mm min. Ambient operating temperature of 70°C: 0 mm min. Relay Mounting Direction Ambient operating temperature of 85°C: 40 mm min. Ambient operating temperature of 70°C: 0 mm min. 3 G 7 L P V - • Install the Relays in locations that are as dry as possible and have as little dust, dirt, and harmful gas as possible. • Using the a Relay under high temperature, high humidity, or harmful gas may deteriorate its performance characteristics due to condensation or corrosive materials, resulting in failure or burn damage to the Relay. • The Relay weight approx. 100 g. Be sure that the PCB is strong enough to support it. We recommend dual-side through-hole PCBs to reduce solder cracking from heat stress. • Install the Relay so that the surface with the markings faces up. (The coil terminals will be at the top and the contact terminals will be at the bottom.) G7L-PV PCB Power Relay - G 7 L P V • Application examples provided in this document are for reference only. In actual applications, confirm equipment functions and safety before using the product. • Consult your OMRON representative before using the product under conditions which are not described in the manual or applying the product to nuclear control systems, railroad systems, aviation systems, vehicles, combustion systems, medical equipment, amusement machines, safety equipment, and other systems or equipment that may have a serious influence on lives and property if used improperly. Make sure that the ratings and performance characteristics of the product provide a margin of safety for the system or equipment, and be sure to provide the system or equipment with double safety mechanisms. Note: Do not use this document to operate the Unit. OMRON Corporation Electronic and Mechanical Components Company 4 Contact: www.omron.com/ecb Cat. No. J202-E1-05 0917(1014)(O)
G7L-2A-P-PV-DC24 价格&库存

很抱歉,暂时无法提供与“G7L-2A-P-PV-DC24”相匹配的价格&库存,您可以联系我们找货

免费人工找货