Founded in 1933, JAPAN
Star-delta Timer
Order Code
H3DT-G
24 to 240 VAC/DC
Dimensions (Unit: mm)
Terminal Arrangement
*
17.5
100
90
86
90
Front
5
Side view
*
Technical criteria
Rated supply voltage
Input method
Power Reset (Minimum power-OFF time)
Control Output
Accuracy of operating time
Setting error
Operating Temperature
Operating Humidity
IP
24 to 240 VAC/DC, 50/60 Hz
None
0.1 s
5 A at 250 VAC with resistive load (cosφ = 1),
5 A at 30 VDC with resistive load,
0.15 A max. at 125 VDC with resistive load,
0.1A max. at 125 VDC with L/R of 7 ms.
Minimum applicable load:10 mA at 5 VDC.
±1% of FS max.
±10% of FS ±0.05 s max.
−20 to 60°C
25% to 85%
IP30 (Terminal block: IP20)
For the most recent information on models that have been certified for safety standards, refer to your OMRON website.
Nomenclature
1
2
3
1
2
3
4
5
4
5
Operation/power indicator
Star operation indicator
Delta operation indicator
Main dial
Star-delta transfer time switch
Time range
Time range setting
Star set time (t1) range
Star-Delta transfer time (t2)
t1x1
1 to 12 s
t1x10
10 to 120 s
Select from 0.05, 0.1, 0.25, or 0.5 s.
Timing Chart
Accessories
Front Cover
Y92A-D1A
Contact: www.ia.omron.com
© OMRON Corporation 2019 All Rights Reserved.
In the interest of product improvement,
specifications are subject to change without notice.
Cat. No. L198-E1-01
1019
很抱歉,暂时无法提供与“H3DT-GAC/DC24-240”相匹配的价格&库存,您可以联系我们找货