0
登录后你可以
  • 下载海量资料
  • 学习在线课程
  • 观看技术视频
  • 写文章/发帖/加入社区
创作中心
发布
  • 发文章

  • 发资料

  • 发帖

  • 提问

  • 发视频

创作活动
H3DT-L2AC/DC24-240

H3DT-L2AC/DC24-240

  • 厂商:

    OMRON(欧姆龙)

  • 封装:

    -

  • 描述:

    EX8MDDPDTACDC24-240VPSHIN

  • 数据手册
  • 价格&库存
H3DT-L2AC/DC24-240 数据手册
Founded in 1933, JAPAN Multi-range, Multi-mode Timer Order Code H3DT-L2 24 to 240 VAC/DC Dimensions (Unit: mm) Terminal Arrangement 17.5 100 90 86 90 Front 5 Side view Technical criteria Rated supply voltage Operating mode Input method Minimum input signal width Power Reset (Minimum power-OFF time) Control Output Accuracy of operating time Setting error Operating Temperature Operating Humidity IP 24 to 240 VAC/DC, 50/60 Hz A, B, B2, C, E, G, J, J2 Voltage input 50 ms (start input) 0.1 s 5 A at 250 VAC with resistive load (cosφ = 1), 5 A at 30 VDC with resistive load, 0.15 A max. at 125 VDC with resistive load, 0.1A max. at 125 VDC with L/R of 7 ms. Minimum applicable load:10 mA at 5 VDC. ±1% of FS max. (±1% ±10 ms max. at 1.2-s range) ±10% of FS ±0.05 s max. −20 to 60°C 25% to 85% IP30 (Terminal block: IP20) For the most recent information on models that have been certified for safety standards, refer to your OMRON website. Nomenclature 1 2 3 5 1 2 3 4 5 6 6 4 INIT/TIME switch for relay R2 Operation/power indicator Output indicator Operating mode switch Time range switch Main dial Time range Time range setting Set time range Scale numbers 0.1 s 0.1 to 1.2 s 1s 1 to 12 s 10 s 10 to 120 s 1 min 1 to 12 min 10 min 10 to 120 min 12 1h 1 to 12 h 10 h 10 to 120 h 100 h 100 to 1,200 h Timing Chart A: ON Delay E: Interval * The start input is ignored while the Timer is in operation. B: Flicker OFF Start G: Signal ON/OFF Delay * The start input is ignored while the Timer is in operation. B2: Flicker ON Start * The start input is ignored while the Timer is in operation. C: Signal ON/OFF Delay * The start input is valid while the Timer is in operation. * The start input is valid while the Timer is in operation. J: One-shot Output (Signal Start) * The start input is valid while the Timer is in operation. J2: One-shot Output (Power ON Start) * The start input is valid while the Timer is in operation. Note: Refer to the official Datasheet, how to use Gate input. Accessories Front Cover Y92A-D1A Contact: www.ia.omron.com © OMRON Corporation 2019 All Rights Reserved. In the interest of product improvement, specifications are subject to change without notice. Cat. No. L193-E1-01 1019
H3DT-L2AC/DC24-240 价格&库存

很抱歉,暂时无法提供与“H3DT-L2AC/DC24-240”相匹配的价格&库存,您可以联系我们找货

免费人工找货