Multifunction Digital Timer
H5BR
Easy-to-Use Timer with Batch Counting
in 72 x 72 mm DIN Size Unit
■ Nine field-selectable output
modes accommodate a wide
variety of applications
■ All parameters set by scrollthrough menus accessed from
the front panel
■ Field-selectable time ranges from
0.001 second to 9999 hours
■ High-visibility alphanumeric LCD
display has 12 mm high characters
and built-in backlight
■ Batch counting function records
the number of completed cycles
■ Contact and solid-state outputs
available simultaneously
■ Precision control possible to
0.001 second
■ Four levels of key protection provided
■ Selectable elapsed time (UP)
and time remaining (DOWN) display
Ordering Information
■ TIMERS
Timing functions
Contact type
Terminal form
Supply voltage
Part number
9 selectable, including ON-delay, repeat cycle, OFF-delay, and one-shot
One SPDT relay and two NPN open collector transistor outputs
16 terminal screws on rear of case
100 to 240 VAC, 50/60 Hz
24 VAC, 50/60 Hz and 12 to 24 VDC
H5BR-B-AC100-240
H5BR-B-AC24/DC12-24
■ ACCESSORIES
Description
Soft cover with two mounting clips for front panel protection
Shock prevention terminal cover protects wiring connections
NEMA 4 waterproof cover
Part number
Y92A-72F1
Y92A-72T
Y92A-72N
H5BR
H5BR
■ RANGE AND OPERATION MODE SELECTION
Range selection
-.---s
--.--s
---.-s
----s
- - min - - s
- - - . - min
- - - - min
- - hr - - min
- - - . - hr
- - - - hr
Time unit
0.001 second
0.01 second
0.1 second
1 second
1 second
0.1 minute
1 minute
1 minute
0.1 hour
1 hour
Maximum setting
9.999 seconds
99.99 seconds
999.9 seconds
9999 seconds
99 minutes 59 seconds
999.9 minutes
9999 minutes
99 hours 59 minutes
999.9 hours
9999 hours
Mode
A
A-1
A-2
A-3
B
B-1
D
E
F
Operation
ON-delay
Sustained start signal ON-delay
Power ON-delay
Power ON-delay/non-power
resettable
Repeat cycle
Repeat cycle/non-power
resettable
OFF-delay
One-shot
Cumulative signal ON-delay
Output type
Sustained or
one-shot*
Sustained
*One-shot output can be set from 0.1 to 99.9 s.
Specifications
Part number
Supply voltage
H5BR-B-AC100-240
100 to 240 VAC, 50/60 Hz
Operating voltage
Power
consumption
85% to 110% of rated voltage
Approximately 8 VA at 50 Hz, 240 VAC
Approximately 5 W at 24 VDC
Start, reset, gate, batch count reset, and key protect
No-voltage input
1 kΩ max. (Approx. 2 mA when 0Ω)
2 V max. in ON state
100 kΩ minimum
1 ms or 20 ms selectable for reset and signal
20 ms for gate and batch count reset
No-voltage input
1 kΩ max. (Approx. 2 mA when 0Ω)
1 V max. in ON state
100 kΩ minimum
1 second
SPDT relay output or NPN open collector transistor output
—
5 A, 250 VAC resistive load (p.f. = 1)
10 mA, 5 VDC
100 mA, 30 VDC
2 V max., 1 V typical
Transistor output (NPN open collector)
±0.01%, ±0.05 second max.
±0.005%, ±0.03 second max. (rate for set value)
—
Power reset (A, A-1, A-2, B, D and E modes)
External, manual, automatic resets (may be internal depending on A-1, B, B-1, D and E
operation modes)
0.5 second minimum (A, A-1, A-2, B, D and E modes)
4-digit LCD alphanumeric display with backlighting
12 mm (0.47 in) H present value, 8 mm (0.31 in) H set value
Retains preset values for 10 years at 20° C (68° F)
Plastic case
Panel
Screw terminals
270 g (9.6 oz)
Inputs
AC
DC
Types available
Signal, Type
reset,
ON impedance
gate,
Residual voltage
batch
count
OFF impedance
reset
Pulse width
Key
protect
Control
output
Type
Relay
Solidstate
Batch output
Repeat accuracy
Type
ON impedance
Residual voltage
OFF impedance
Response time
Time limit
Instantaneous
Max. load
Min. load
Max. load
Residual voltage
Power start
Signal start
Setting error
Resetting system
Resetting time
Indicators
Memory function
Materials
Mounting
Connections
Weight
Power reset
2
H5BR-B-AC24/DC12-24
24 VAC, 50/60 Hz and 12 to 24 VDC
(permissible ripple: 20% max.)
H5BR
H5BR
SPECIFICATIONS continued
Approvals
Operating ambient temperature
Humidity
Vibration Mechanical durability
Malfunction durability
Shock
Mechanical durability
Malfunction durability
Variation due to voltage change
Variation due to temperature change
Insulation resistance
Dielectric strength
Service life
(SPDT relay)
Mechanical
Electrical
UL/ CSA/SEV/CE (EMC)
-10° to 55°C (14° to 131°F) with no icing
35% to 85% RH
10 to 55 Hz with 0.75 mm (0.03 in) single amplitude in 3 directions
10 to 55 Hz with 0.5 mm (0.02 in) single amplitude in 3 directions
30 G each in three directions
10 G each in three directions
Included in "Repeat accuracy" specification
Included in "Repeat accuracy" specification
100 MΩ min. at 500 VDC between current-carrying terminal and exposed non-currentcarrying metal parts, and between non-continuous contacts.
2,000 VAC, 50/60 Hz for 1 minute between current-carrying terminal and exposed
non-current-carrying metal parts for 100 to 240 VAC type
1,000 VAC for both 24 VAC and 12 to 24 VDC types
10 million operations minimum
100,000 operations minimum at 5 A, 240 VAC, resistive load (p.f. = 1)
Timing Charts
■ OPERATION MODES
Output mode A: Signal ON delay 1 (Timer resets when power comes on.)
Timing begins at the leading edge of
the start signal. The control output will
be energized when the present value
equals the preset time. The output will
be sustained until a reset signal is
applied, until power is interrupted, or
for a programmable one-shot time
period.
Power
Start signal
Gate
Reset
Control output
Set value
Timing
UP
0
diagram
Set value
DOWN 0
Output mode A1: Signal ON delay 2 (Timer resets when power comes on.)
Timing begins at the leading edge of the
start signal. The control output will be
energized if the start signal is sustained
for an amount of time equal to the preset
time. The output will be sustained until
the start signal is interrupted, until a reset
signal is applied, until power is
interrupted, or for a programmable oneshot time period.
Power
Start signal
Gate
Reset
Control output
Set value
UP
0
Timing
Set value
diagram
DOWN 0
One-shot
One-shot output can be set from 0.1 s to 99.9 s.
Sustained output
3
H5BR
H5BR
Output mode A-2: Power ON delay 1 (Timer resets when power comes on.)
Timing begins when power is applied.
Start signals act as a gate input,
causing the present value to hold. The
control output will be energized when
the present value equals the preset
time. The output will be sustained until
a reset signal is applied, until power is
interrupted, or for a programmable
one-shot time period.
Power
Start signal
Gate
Reset
Timing
diagram
Control output
Set value
UP
0
Set value
DOWN 0
Output mode A-3: Power ON delay 2 (Timer does not reset when power comes on.)
Timing begins when power is applied.
Start signals act as a gate input, causing
the present value to hold. The control
output will be energized when the
present value equals the preset time.
The output will be sustained until a reset
signal is applied or for a programmable
one-shot time period. If power to the unit
is interrupted, the control output will be
de-energized. The output will reenergize once power is restored.
Power
Start signal
Gate
Reset
Timing
diagram
Control output
Set value
UP
0
Set value
DOWN 0
Output mode B: Repeat cycle 1 (Timer resets when power comes on.)
The OFF/ON cycle is initiated at the
leading edge of the start signal. The
output relay will be OFF for the preset
time, then ON for the preset time. The
cycle will be repeated until a reset input
is applied or power is interrupted.
Power
Start signal
Gate
Reset
Timing
diagram
Control output
Set value
UP
0
Set value
DOWN 0
The OFF/ON cycle is initiated at the
leading edge of the start signal. The
control output will be OFF for the first
cycle. In subsequent cycles the output
will be ON for the programmable oneshot time period, then OFF for the
remainder of the preset time. The cycle
will be repeated until a reset input is
applied or power is interrupted.
Power
Start signal
Gate
Reset
Timing
diagram
Control output
Set value
UP
0
Set value
DOWN 0
One-shot
Sustained output
One-shot output can be set from 0.1 s to 99.9 s.
a = one-shot time before power interruption
t-a = remaining one-shot time after power interruption
4
H5BR
H5BR
Output mode B-1: Repeat cycle 2 (Timer does not reset when power comes on.)
The OFF/ON cycle is initiated at the
leading edge of the start signal. The
output relay will be OFF for the preset
time, then ON for the preset time. The
cycle will be repeated until a reset input
is applied. If power to the unit is
interrupted, the present value will hold.
The cycle will continue from that point
once power is restored.
Power
Start signal
Gate
Reset
Timing
diagram
Control output
Set value
UP
0
Set value
DOWN 0
The OFF/ON cycle is initiated at the
leading edge of the start signal. The
control output will be OFF for the first
cycle. In subsequent cycles the output
will be ON for the programmable oneshot time period, then OFF for the
remainder of the preset time. The cycle
will be repeated until a reset input is
applied. If power to the unit is
interrupted, the present value will hold.
The cycle will continue from that point
once power is restored.
Power
Start signal
Gate
Reset
Timing
diagram
Control output
Set value
UP
0
Set value
DOWN 0
Output mode D: Signal OFF delay (Timer resets when power comes on.)
The control output is energized at the
leading edge of the start signal. Timing
begins at the trailing edge of the start
signal. The control output is deenergized when the present value equals
the preset time.
Power
Start signal
Gate
Reset
Timing
diagram
Control output
Set value
UP
0
Set value
DOWN 0
Output mode E: Interval (Timer resets when power comes on.)
Timing begins on the leading edge of the
start signal. The control output is only
energized during timing. The timer is
reset when power is interrupted or a
reset signal is applied.
Power
Start signal
Gate
Reset
Timing
diagram
Control output
Set value
UP
0
Set value
DOWN 0
One-shot
Sustained output
One-shot output can be set from 0.1 s to 99.9 s.
a = one-shot time before power interruption
t-a = remaining one-shot time after power interruption
5
H5BR
H5BR
Output mode F: Cumulative (Timer does not reset when power comes on.)
Timing begins on the leading edge of the
start signal. The control output is
energized when the cumulative elapsed
time of the start signal is equal to the
preset time. The output is sustained until
power is interrupted or a reset signal is
applied.
Power
Start signal
Gate
Reset
Timing
diagram
Control output
Set value
UP
0
Set value
DOWN 0
■ BATCH COUNTER OPERATION
The batch count output holds until reset
by the batch count reset. The present
value of the batch count advances
continuously.
Batch count reset
Batch count set
value
Batch count
present value 0
Batch output
1. The batch count present value remains
at 0 while the batch count reset is ON.
2. When the batch count set value is 0,
the batch count will proceed, but there
will be no output.
3. When the batch count present value
exceeds 9999, it returns to 0.
4. The batch count present value and
output are not affected by the RESET
key or reset input.
5. When power is interrupted and the
batch count output is ON, the output
will be ON when power returns.
6. When a batch count set value greater
than the present value is changed to a
set value less than the present value,
the output will go ON.
7. If, after the output has gone ON, the set
value is changed to a set value that is
greater than the present value, the
output will remain ON.
8. When utilizing latching outputs in the
repeat cycle modes (B and B1), the
number of completed timing is double
the number of outputs. To control the
number of outputs, set the batch count
set value at double the desired number
of outputs.
Dimensions
Unit: mm (inch)
■ TIMER
6
(0.24)
72
(2.83)
100
(3.94)
M3.5 terminal screw,
effective length: 6 mm (0.24)
67.6
(2.66)
72
(2.83)
6
H5BR
H5BR
■ PANEL MOUNTING H5BR TIMERS
A pair of panel mounting adapters is included with the timer. The adapters are installed in the slots on the right and left sides of the case,
as shown below.
6
(0.24)
100 min.
(3.94)
Panel Cutouts
100
(3.94)
7 + panel thickness
+0.7
-0
68
(2.68)
Panel cutouts shown at right
conform to DIN 43700.
68 +0.7
-0
(2.68)
82 min.
(3.23)
■ ACCESSORIES
Y92A-72F1 Soft plastic cover
Two mounting clips help the soft plastic cover Y92A-72F1 fit
snugly over the front of the timer to protect against dirt and
water. Timer settings can be changed when the cover is on.
The cover is intended for use in areas where unusual service
conditions do not exist.
Y92A-72T Terminal cover
The terminal cover protects wiring connections.
69
(2.72)
75.8
(2.98)
69
(2.72)
75.8
(2.98)
Connections
■ TERMINAL ARRANGEMENT
H5BR-B
AUX POWER
12 VDC
80 mA max.
GATE
Note: Do not connect unused terminals.
SIGNAL
100 mA max.
30 VDC
RESET
BATCH
0V
BATCH RST
5A
250 VAC
KEY/P
TIMED
SOURCE
TIMED
100 mA max.
30 VDC
7
H5BR
H5BR
■ INPUTS
The inputs of the H5BR are no-voltage (short circuit or open) inputs.
Contact Input
No-contact Input
(NPN Transistor)
No-contact Input
+V
Sensor
Timer
Timer
Timer
Start signal,
reset, etc.
Start signal,
reset, etc.
12 VDC
Start signal,
reset, etc.
Input use 0 V
Input use 0 V
Input use 0 V
High: contact ON
High: transistor ON
1. High level
Transistor ON
No-contact
Residual voltage: 2 V max.
input
Impedance when ON:
1 kΩ max.
2. Low level
Transistor OFF
Impedance when OFF:
100 kΩ min.
Contact
Use contacts which can
input
adequately switch 2 mA
at 5 V.
Voltage supply
DC-
DC+
12 VDC, 80 mA
8
12
Input terminal numbers (no voltage)
Start
10
Gate
11
High: transistor ON
Terminal Numbers on Power Supply
for External Equipment
No-voltage Input Signal Levels
Reset
9
(30 V max.)
Sensor
Power supply terminals
Batch
reset
Key
protect
15
16
COM
8
AC
(common),
DC–
AC
(hot),
DC+
1
2
Contact
COM
3
Output terminal numbers
Solid-state
Timed
Batch
NO NC
COM Load COM Load
4
5
6
7
13
14
Operation
■ NOMENCLATURE
Reset
indicator
Gate
indicator
Key protection
indicator
Signal
input
indicator
Control
output
indicator
Batch output
indicator
Power
indicator
PW SG RST GT
OUT
BATCH
Elapsed time indicator
Indicates the fraction of the unit that has
elapsed. Displayed for timing ranges of
9999 min. or greater.
Present value
Character height: 12 mm (0.47 in)
Nonsignificant zeros suppressed
Set value
Character height: 8 mm (0.31 in)
Value in set function mode
Mode
indicator
4
Reset
key
Timing
indicator
2
3
1
MODE
BATCH
Mode
key
Batch
key
8
Increment
keys (1–4)
DISPLAY
Display
key
H5BR
H5BR
■ KEY OPERATIONS
Key name
Increment keys (1-4)
Display key
Batch key
Mode key
Reset key
Operation
Used to change the corresponding digit of the set value. Used to change data in the set mode.
Switches to the present value display.
Switches to the batch display.
Switches from run mode to set mode. Changes items in the set mode.
Resets timing and outputs.
■ FACTORY SETTINGS
The following table shows the timer settings when it is shipped. Change the settings as necessary to suit the system before
operation. Settings and the display receive power from the internal battery and are, therefore, unaffected by external power
interruptions. With the initial settings, there will be no output even if the power supply is connected. External inputs and outputs
cannot be used without a power supply.
Model
Time range
Present value
Presets
Batch present count
Batch preset
UP/DOWN mode
Output mode
Output time
Input signal time
Key protect level
H5BR-B (Standard)
- -.- -s
0.00 s
0.00 s
0
0
UP
A: Signal ON-delay (1)
Hold
20 ms
KP-1
■ INPUT/OUTPUT FUNCTIONS
Inputs
Start signal
Reset
Gate
Batch count reset
Key protect
Outputs
Control output (OUT)
Batch output
Stops timing in A-2 and A-3 (power ON-delay) modes. Starts timing in other modes.
Resets present value (to zero in UP mode, to preset in DOWN mode).
Control inputs are not accepted while reset input is ON.
Reset indicator lit while reset input is ON.
Inhibits timer operation.
Resets batch count to zero and batch output turns OFF on leading edge.
Batch count signals are not accepted while batch count reset is ON.
Makes keys inoperative according to key protect level; four levels available.
Key protected indicator lit while key protect input is ON.
Effective when protect terminals are shorted.
Effective if power supply is turned off.
Outputs made according to designated output mode when corresponding preset is reached.
Outputs made when batch count equals the preset number of batches.
Batch output remains ON until batch count reset goes ON.
When the number of batches is set to zero, batch counting is performed, but batch outputs
are not made.
■ BATCH COUNTER APPLICATION
Counting the Number of Bottles Filled
DISPLAY
Fill time = 3.5 seconds
Batch preset = 500
BATCH
9
H5BR
H5BR
■ OPERATIONAL OVERVIEW
Refer to the Setting Item Table below for details on the operation of specific modes.
Run mode
Press the
BATCH key
Present value,
set value
Note: 1. Set values are changed using
the increment keys (1 to 4).
2. The large arrow indicates the
parameter displayed first when the mode
is changed with the MODE or DISPLAY key.
Batch count value,
set value
Press the
DISPLAY key
Press the
MODE key
Press the
DISPLAY key
Setting mode
Press the
MODE key
Timing range
Press the
MODE key
UP/DOWN mode
Press the
MODE key
Output mode
Press the
MODE key
Press the
MODE key
Key protect
Input signal time
level
Output time
■ SETTING ITEM TABLE
Mode
Run mode
Setting mode
Setting item
Set value
Description
Compared to the present value.
Determines the timing of the control
output according to the output mode.
Setting procedure
Sequence when changing a digit using the
increment keys (1 to 4).
Batch count set
value
Turns ON the batch output when
the preset number of cycles have been
completed.
Sequence when changing a digit using the
increment keys (1 to 4).
Time range
Determines the timing range.
UP/DOWN mode
Selects the display that shows elapsed
time (UP) or time remaining (DOWN).
Change the timing range with the increment
keys (1 to 4).
Select UP/DOWN with the increment keys
(1 to 4).
Output mode
Determines the control output type.
(Refer to the Operation Modes Timing
Charts on pages 18 to 21.)
Sequence when changing the mode using the
increment keys (1 to 4).
Output time
Determines the duration of the control
output. Will be displayed when the
output mode is A, A-1, A-2, A-3, B,
or B-1. Will not be displayed in
output modes D, E, or F.
Use keys 1 to 3 to change the value.
Key 1 adjusts the first digit (0.1 digit).
Key 2 adjusts the second digit (1 digit).
Key 3 adjusts the third digit (10 digit).
Key 4 selects either hold output or one-shot output.
Input signal time
Changes the duration of the control
and reset input signals.
Change the duration with increment keys
(1 to 4).
Key protect level
Locks certain keys to prevent accidental Sequence when changing the key protect
operation. The key protection level,
level using the increment keys (1 to 4).
kP-1 to kP-4, determines which keys are
locked when the key protection input
is ON. The locked keys are crossed
out in the diagram at right.
Note:
1. Changes made in setting mode become effective when run mode is entered.
2. The time range setting appears first when setting mode is entered.
10
H5BR
H5BR
■ EXAMPLES
Run Mode
Changing the Set Value
To change the set value from 3 hr 5 min to 4 hr 5 min, press
the 3 key so that the number 4 appears in the hour's place.
• Pressing keys 1 through 4 increments the corresponding
column by 1.
• The columns can be changed in any order, but the output will
be turned ON if the set value is less than the present value.
• Nonsignificant zeros are suppressed on the set value display.
Note: Read Changing Set Values in the Precautions section
before changing the timer set value during operation.
Changing the Batch Count Set Value
1. Press the BATCH key to switch from the present value
display to the batch count display.
2. Change the set value when the timer is set to the batch
count display.
• Nonsignificant zeros are normally suppressed on the batch
count set value display.
• Press the DISPLAY key to switch back from the batch
count display to the present value display.
Setting Mode
Changing Settings in the Set Mode
1. Press the MODE key to switch from run mode to set mode.
• The timer will continue operation according to existing
settings when switched from run mode to set mode during
operation.
2. Press the MODE key to scroll successively through the items
that can be set.
• The MODE key will be locked if the key protection function
is enabled.
• Settings changed in the set mode do not take effect until
run mode is entered. Because the operating conditions will
change once this occurs, always use the RESET key or a
reset input to reset operation.
11
H5BR
H5BR
3. To change the selected item,
• Press the MODE key until the desired item appears.
• Change the item setting by pressing keys 1 through 4.
(Press the DISPLAY key to switch back from set mode to
run mode.)
Precautions
■ EXTERNAL POWER SUPPLY
• The capacity of the external power supply is 80 mA at 12
VDC. When using a 24 VAC/12 to 24 VDC power supply,
reduce the load with the power supply voltage, as shown in
the following diagram (DC power supplies only).
• Be sure that the capacity of the external power supply is
adequate, because the power supply may not provide a
surge current sufficient to start the timer due to the switching
regulator contained in the timer's internal circuitry.
■ INPUT AND OUTPUT
• Do not use external sources to increase the voltage of input
signals (control signal, reset, gate, and key protection).
• Be sure that the load of the control output (contact, transistor)
is less than the maximum values indicated in the
specifications. If the output load exceeds the recommended
value, the life span of the contact output type will be
shortened dramatically, and the transistor of the transistor
output type will be damaged.
• The transistor output is opto-isolated from the internal
circuitry, so either NPN or PNP transistors can be used.
■ SELF-DIAGNOSTIC FUNCTION
• The following displays will appear if an error occurs. The
present value and output enter the same status as after
pressing the RESET key.
■ POWER SUPPLIES
• If power is interrupted for less than 10 ms, operation will
continue normally. If power is interrupted for 10 to 500 ms,
operation will be inconsistent, and timing may stop or reset,
depending on the mode.
Display
Error
CPU
• Connect the power supply voltage through a relay or switch
in such a way that the voltage reaches a fixed value
immediately.
Memory
• Depending on switching frequency, current surges may
degrade relay contacts; relays with a capacity greater than
10 A are recommended.
12
Output
status
OFF
Correction
Set
Press
RESET
key
(batch
count to 0)
No
change
Set at the
factory
H5BR
H5BR
■ CHANGING SET VALUES
■ OTHER
• The timer set value can be changed while the timer is
operating, so a high value can be set temporarily to
inactivate the timer, or a low value can be set to activate the
timer more quickly. If the set value is changed accidentally
during operation, the timed output might be activated.
Therefore, turn the key protection input ON unless the set
value is being changed.
• When the timer is installed in a control box and tests are
conducted which may damage the timer's internal circuitry
(for example, a test measuring the maximum voltage
difference between the control circuit and metal
components), remove the timer from the control box or short
circuit the terminals.
• To avoid changing the output when changing the set value, it
is recommended to begin changing the set value by entering
a large number in the higher digit.
CAUTION
This product contains a lithium battery. Lithium batteries
explode if incinerated. Dispose of the digital timer as a noncombustible item.
■ OPERATING ENVIRONMENT
• When using the timer in an area with much electrical noise,
separate the timer, wiring, and the equipment which
generates the input signals as far as possible from the noise
sources. It is also recommended to shield the input signal
wiring to prevent electrical interference.
• Organic solvents (such as paint thinner), as well as very
acidic or basic solutions, might damage the outer casing of
the timer.
NOTE: DIMENSIONS ARE SHOWN IN MILLIMETERS. To convert millimeters to inches divide by 25.4.
OMRON ELECTRONICS LLC
OMRON ON-LINE
OMRON CANADA, INC.
One East Commerce Drive
Schaumburg, IL 60173
Global - http://www.omron.com
USA - http://www.omron.com/oei
Canada - http://www.omron.com/oci
885 Milner Avenue
Scarborough, Ontario M1B 5V8
1-800-55-OMRON
Cat. No. GC TMCN1
3/02
Specifications subject to change without notice.
13
416-286-6465
Printed in the U.S.A.