Digital Timer
H5CN
Please read and understand this catalog before purchasing the products. Please consult your OMRON representative if your have any questions or comments. Refer to Warranty and Application Considerations
(page 16), and Safety Precautions (page 13).
Miniature DIN-sized (48 x 48 mm) Quartz
Timer with Abundant Series Versions
• Series version cover a wide range of rated times; 9.999 s,
99.99 s, 999.9 s, 99 min 59 s, and 99 hrs 59 min.
• Selection of elapsed time indication, remaining time indication,
contact output, and solid-state output types to suit requirements.
• Power supply freely selectable within a range of 100 to
240 VAC, as well as 12 to 48 VDC.
• Models with a memory backup function against power failure
available.
Model Number Structure
■ Model Number Legend
Note: This model number legend includes combinations that are not available. Before ordering, please check the List of Models on page 2 for availability.
H5CN- @@N@@
1 2 3 4 5
1. Display
X: UP display (increments from 0 to the set time)
Y: DOWN display (decrements from the set time to 0)
2. Rated time
Z: 0.001 to 9.999 s
A: 0.001 to 99.99 s
B: 0.1 to 999.9 s
C:1 s to 99 min 59 s
D:1 min to 99 h 59 min
3. Output mode
N: N mode (Power ON-delay)
4. Backup power supply function for memory protection
None: Not provided
M:
Provided
5. Output type
None: Contact output (SPDT)
S:
Solid-state output
Digital Timer
H5CN
1
Ordering Information
■ List of Models
Display type
UP display timer (increments form DOWN display timer (decre0 to the set time)
ments form the set time to 0)
UP display timer (increments from 0
to the set time)
Output type
Contact output (SPDT)
Solid-state output
Pin type
11-pin
Backup power supply function for
memory protection
Not provided
Uses external
battery (lithium).
(See notes 2 and
3.)
Supply voltage
100 to 240 VAC
100 to 240 VAC, 12 to 48 VDC
Rated time
0.001 to 9.999 s
---
---
---
H5CN-XZNS
0.001 to 99.99 s
H5CN-XANM
H5CN-XAN
H5CN-YAN
H5CN-XANS
0.1 to 999.9 s
H5CN-XBNM
H5CN-XBN
H5CN-YBN
---
1 s to 99 min 59 s
H5CN-XCNM
H5CN-XCN
H5CN-YCN
---
1 min to 99 h 59 min
H5CN-XDNM
H5CN-XDN
H5CN-YDN
---
8-pin
12 to 48 VDC
Note: 1. Specify both the model number and supply voltage when ordering.
Example: H5CN-XAN 12 to 48 VDC
Supply voltage
2. The Y92S-20 Backup Battery (sold separately) provides power backup for memory protection during power failures for approximately
5 years (at 20°C). Always connect a battery to the H5CN-X@NM. For details on connection methods, refer to page 5.
3. The H5CN-X@NM does not support power resetting.
■ Accessories (Order Separately)
Name
Flush Mounting Adapter
Models
Y92F-30
Backup Battery
Y92S-20
Track Mounting/Front
Connecting Socket
8-pin
P2CF-08
11-pin
P2CF-11
Back Connecting Socket
8-pin
P3G-08
11-pin
P3GA-11
Hard Cover
Y92A-48B
Protective Cover
Mounting Track
Soft Cover
Y92A-48D
50 cm (I) ´ 7.3 mm (t)
PFP-50N
1 m (I) ´ 7.3 mm (t)
PFP-100N
1 m (I) ´ 16 mm (t)
PFP-100N2
End Plate
PFP-M
Spacer
PFP-S
2
Digital Timer H5CN
Specifications
■ Ratings
Item
Rated supply voltage
Contact output
Solid-state output
100 to 240 VAC (50/60 Hz), 12 to 48 VDC (permissible rip- 12 to 48 VDC (permissible ripple: 20% max.)
ple: 20% max.) (see note)
Operating voltage range 85% to 110% of rated supply voltage
Power consumption
Approx. 12 VA at 240 VAC, 50 Hz
Approx. 2.5 W at 48 VDC
Approx. 2.5 W at 48 VDC
Mounting method
Surface mounting or flush mounting
Display
7-segment LEDs (8-mm-high characters), UP indicator
Input method
Contact open and short-circuit input
Resetting system and
gate input
Reset by power-OFF (not provided for models with backup power for memory protection):
min. power OFF time: 0.5 s
External reset or gate (common to contact and solid-state inputs): min. reset input signal width: 0.02 s;
residual voltage: 2 V max.
Output mode
N mode (Power ON-delay)
Control outputs
SPDT: 3 A at 250 VAC, resistive load (cosf = 1)
Ambient temperature
Operating:–10°C to 55°C (with no icing or condensation)
Storage:–25°C to 65°C (with no icing or condensation)
Ambient humidity
Operating: 35% to 85%
Case color
Light gray (Munsell 5Y7/1)
Open-collector transistor ON/OFF input
Open collector: 100 mA max. at 30 VDC max.
Note: Models with memory backup function are not available for this range of DC supply voltages.
■ Characteristics
Accuracy of operating time
±0.01% ±0.05 s max. (see note 1), ±0.005% ±0.03 s max. (see note 2) (see note 3)
Setting error
Influence of voltage
Influence of temperature
Insulation resistance
100 MW min. (at 500 VDC) (between current-carrying terminal and exposed non-current carrying
metal parts, between power supply circuit and control output circuit)
Dielectric strength
2,000 VAC, 50/60 Hz for 1 min (between current-carrying terminal and exposed non-current-carrying
metal parts, between power supply circuit and control output circuit)
Impulse withstand voltage
6 kV (between power supply terminal)
6 kV (between current-carrying terminal and exposed non-current carrying metal parts)
Noise immunity
Square-wave noise by noise simulator
AC: ±2 kV (between power supply terminals)
DC: ±480 V (between power supply terminals), ±500 V (between input terminals)
Static immunity
Malfunction: 8 kV
Vibration resistance
Destruction:10 to 55 Hz with 0.75-mm single amplitude each in 3 directions for 2 hours each
Malfunction:10 to 55 Hz with 0.5-mm single amplitude each in 3 directions for 10 minutes each
Shock resistance
Destruction:300 m/s2 3 times each in 6 directions
Malfunction:100 m/s2 3 times each in 6 directions
Life expectancy
Mechanical:10,000,000 operations min.
Electrical:100,000 operations min. (3 A at 250 VAC, resistive load)
Approved standards
UL508, CSA C22.2 No. 14
Weight
Approx. 200 g
Note: 1. When timer operation is started by power application.
2. When timer operation is started after a reset input has been applied.
3. These values represent the total accuracy of the timer including the repeat accuracy, setting error, and variation due to voltage and temperature changes. Note that they also comprise errors due to the rise time of the power source and the operating times of the internal
and output circuits.
Digital Timer
H5CN
3
Number of switching operations (×104 times)
■ Life-test Curve (Reference Values)
1,000
700
500
300
100
70
50
30 VDC cosφ =1
30
250 VAC cosφ =1
10
7
5
0
250 VAC cosφ =0.4
1
30 VDC L/R = 7 ms
2
3
4
Load current (A)
A maximum current of 0.15A can be switched at 125 VDC (cosf = 1)
Maximum current of 0.1 A can be switched if L/R is 7 ms. In both
cases, a life of 100,000 operations can be expected. The minimum
applicable load is 10 mA at 5 VDC (failure level: P reference value).
4
Digital Timer H5CN
Connections
■ Block Diagram
H5CN-@@N (without Backup Power for Memory Protection)
Using an AC Power Supply (Contact Outputs)
One-shot timer
circuit
Thumbwheel
switch
Clock
Initial clear
circuit
Quartzcrystal
oscillator
Microcomputertype custom LSI
Timer circuit
Reset input
Filter
7-segment
indicator
Output
circuit
Gate input
Filter
Filter
UP display
Note: 1. If the reset input is short-circuited (between terminals A and C), immediately
the count circuit is reset to 0 and the control output relay is reset to OFF. The timer starts as soon as the reset input is
opened (between terminals A and C).
2. If the gate input is short-circuited (between terminals A and D), the count circuit stops immediately. The timer then
restarts as soon as the gate input is
opened (between terminals A and D).
Constantvoltage
circuit
Rectifier
circuit
Using a DC Power Supply (Solid-state Outputs)
Note: The following block diagram shows the differences for the equivalent section indicated by “a” in the above block diagram.
Reset input
Filter
Filter
Gate input
Note: Terminals A and B are internally short-circuited.
Filter
Constantvoltage
circuit
Power
supply
circuit
Digital Timer
H5CN
5
H5CN-X@NM (with Backup Power for Memory Protection)
Note: Be sure to install a Backup Battery (sold separately).
One-shot timer
circuit
Thumbwheel
switch
Clock
Power failure
detection
circuit
Quartzcrystal
oscillator
Microcomputertype custom LSI
Timer circuit
Gate input
Filter
Filter
7-segment
indicator
Output
circuit
Reset input
Filter
UP indicator lit
Constantvoltage
circuit
External
battery
Rectifier
circuit
6
Digital Timer H5CN
Note: 1. If the reset input is short-circuited (between terminals C and G), immediately
the count circuit is initialized and the control output relay is reset to OFF. The timer
starts as soon as the reset input is opened
(between terminals C and G).
2. If the gate input is short-circuited (between terminals C and E), the count circuit stops immediately. The timer then
restarts as soon as the gate input is
opened (between terminals C and E).
Installation
■ Connections
1. Battery Connection (H5CN-X@NM
Only)
Connecting of Load Circuit
Load 1 connected in series with NO contact (between terminals F
and H) is normally open, and the load circuit voltage will be applied
after the lapse of the set time. The load circuit voltage is normally
applied to load 2 connected in series with NC contact (between terminals E and H), which will be open after the lapse of the set time.
Load 2
Model with Backup
Power for Memory
Protection
External
battery 3 V
Connect the Y92S-20 Backup Battery between terminals A and D,
making sure the polarities are correct.
Load 1
Load circuit voltage
(250 VAC, 30 VDC max.)
Note: The maximum load current is 3 A (resistive load).
2. Power Supply Connection
Solid-state Output Type
Model without Backup Power for Memory
Protection
Internal Circuit of Control Output
Terminals F and H are an open collector output. A diode is internally connected between terminals E and F to absorb counterelectromotive force that occurs when an inductive load is connected.
Connect the timer so that the required supply voltage can be applied
across terminals B and G. (Make sure that the polarity of the DC
power supply is correct.)
AC Power Supply
DC Power Supply
Connection of Load Circuit
Voltage is applied to the load after the set time has lapsed.
12 to 48 VDC
100 to 240 VAC
Model with Backup Power for Memory
Protection (H5CN-X@NM)
Load
Load voltage
(30 VDC max.)
Connect the timer so that the required supply voltage can be applied
across terminals B and J.
Note: The maximum load current is 100 mA.
Model with Backup Power for Memory
Protection (H5CN-X@NM)
External
battery
Contact Output Type
100 to 240 VAC
Internal Circuit of Control Output Contacts
Terminal H, I, and K are for control output contacts.
3. Connection of Load Circuit (Control
Output)
Model without Backup Power for Memory
Protection
External
battery
Contact Output Type
Internal Circuit of Control Output
Contacts
Terminals E, F, and H are for control output contacts.
Digital Timer
H5CN
7
Connection of Load Circuit
Load 1 connected in series with NO contact (between terminals I
and K) is normally open, and the load circuit voltage will be applied
to it after the lapse of the set time. The load circuit voltage is normally
applied to load 2 connected in series with NC contact (between terminals H and K), which will be open after the lapse of the set time.
Load 2
Load 1
External
battery
Load circuit
voltage
(250 VAC,
30 VDC max.)
Note: The maximum load current is 3 A (resistive load).
4. Connection of Reset Input
Connection of the reset input contact or an open collector transistor
between terminals A and C (between terminals C and G for models with backup power for memory protection) permits the timer to
reset when contact is made or the transistor turns ON. Use of a highreliability gold-plated contact is recommended for the reset input. For
the reset input transistor, select the one satisfying the following electrical ratings:
VCEO = 20 V min.
IC = 50 mA min.
ICEO (leakage current) = 0.5 m A max.
VCE(sat) (residual voltage) = 2 V max.
Model without Backup Power for Memory
Protection
Reset input
contact
(Timer resets
when contact is
made.)
5. Connection of Gate Input
Connection of the gate input contact or an open collector transistor
between terminals A and D (between terminals C and E for models with backup power for memory protection) permits the timer to
stop operation while contact is made or the transistor turns ON. Use
of a high-reliability gold-plated contact is recommended for the gate
input. For the gate input transistor, select the one satisfying the following electrical ratings:
VCEO = 20 V min.
IC = 50 mA min.
ICEO (leakage current) = 0.1 mA max.
VCE(sat) (residual voltage) = 2 V max.
Use a gate input contact with a short bounce time because the contact bounce time causes an error in the operate time of the timer for a
period equalling the bounce time.
Model without Backup Power for Memory
Protection
Gate input contact
(Timer stops when
contact is made.)
Gate input transistor
(Timer stops when
transistor is ON.)
Model with Backup Power for Memory
Protection (H5CN-X@NM)
Gate input contact
(Timer stops when
contact is made.)
Reset input
transistor
(Timer resets
when transistor
is ON.)
External
battery
Model with Backup Power for Memory
Protection (H5CN-X@NM)
Gate input transistor
(Timer stops when
transistor is ON.)
External
battery
Reset input
contact
(Timer resets
when contact is
made.)
External
battery
Reset input
transistor
(Timer resets
when transistor
is ON.)
External
battery
8
Digital Timer H5CN
6. Battery Connections when Using
Backup Power for Memory Protection
Always connect a battery when using models with backup power for
memory protection (H5CN-X@NM). Any 3-V battery can be used, but
the backup time will depend on the capacity of the battery.
When using the Unit for the first time after purchase, apply power
and reset the Unit once before using it. When power is turned ON for
the first time, outputs may be produced at the same time, so do not
connect the output terminals.
When connecting the battery using a Socket (P2CF-11 or P3GA-11),
check the terminal numbers on the Socket and connect the positive
side of the battery to terminal D and the negative side to terminal A.
Operation
■ Timing Chart
Digital Display
UP Display
DOWN Display
Time up
Power ON
Gate input
Setting value
Setting value
Digital display
No digital
display
Reset input
Gate input
Digital display
0
0
Power supply
Power supply
Control output
Control output
Time up indication
Time up indication
Time up
No digital
display
Power ON
Reset input
Digital Timer
H5CN
9
Dimensions
Note: All units are in millimeters unless otherwise indicated.
■ Dimensions without Flush Mounting Adapter
H5CN-X@N/-Y@N/-X@NS (Flush Mounting/Surface Mounting Models)
44.8 × 44.8
▲
8 pins
H5CN-X@NM (Flush Mounting/Surface Mounting Models)
44.8 × 44.8
▲
11 pins
■ Dimensions with Flush Mounting Adapter
H5CN-X@N/-Y@N/-X@NS (Adapter Ordered Separately)
Panel
Y92F-30 (order separately)
Flush Mounting Adapter
P3G-08 (order separately)
Back Connecting Socket
Panel Cutout
The standard panel cutout is as below.
(Panel cutout conforms to DIN 43700.)
45 +0.6
−0
+0.6
45 −0
Gang-mounting of more than 2 units
(horizontally)
95.1
+0.6
45 −0
H5CN-X@NM (Adapter Ordered Separately)
Panel
Y92F-30 (order separately)
Flush Mounting Adapter
P3GA-11 (order separately)
Back Connecting Socket
■ Dimensions with Front Connecting Socket
H5CN
-X@N,Y@N,
X@NS
P2CF-08
H5CN
-X@NM
P2CF-11
Note: These dimensions vary with the kind of DIN track (reference value).
10
Digital Timer H5CN
N
Note: 1. Panel thickness: 1 to 5 mm
2. When gang-mounting the Unit, the
orientation of the Adapter must be
changed depending on whether
Units are mounted horizontally or
vertically.
3. No cover:
N = (48n − 2.5) +1/−0
With hard cover:
N = {48n − 2.5 + (n − 1) x 3} +1/−0
■ Accessories (Order Separately)
Note: All units are in millimeters unless otherwise indicated.
Track Mounting/Front Connecting Socket
P2CF-08
Eight,
M3.5 x 7.5 sems
4.5
3
7.8
Terminal Arrangement/
Internal Connections
(Top View)
Surface Mounting Holes
Two, 4.5 dia. or two, M4
70 max.
35.4
Two, 4.5 dia.
holes
40±0.2
4
50 max.
20.3 max.
Track Mounting/Front Connecting Socket
P2CF-11
Eleven,
M3.5 x 7.5 sems
7.8
3
4.5
Terminal Arrangement/
Internal Connections
(Top View)
Surface Mounting Holes
Two, 4.5 dia. or two, M4
70 max.
35.4
40±0.2
Two, 4.5 dia.
holes
4
50 max.
31.2 max.
Back Connecting Socket
P3G-08
Terminal Arrangement/
Internal Connections
(Bottom View)
27 dia.
45
45
4.9
17
Terminal Arrangement/
Internal Connections
(Bottom View)
P3GA-11
27 dia.
45
25.6
45
4.5
16.3
6.2
Digital Timer
H5CN
11
Backup Battery
Y92S-20
22.5 dia.
Red lead wire (0.18 × 12 conductors)
L=120 mm
Note: Always connect a battery to models with
backup power for memory protection
(H5CN-@M).
4.5 dia. hole
Hard Cover
Y92A-48B (See note 2.)
Soft Cover
Y92A-48D (See note 1.)
Note: 1. The soft protective cover allows the set value to be set by
depressing the thumbwheel switches through it. It may be,
however, difficult to make setting changes of the Timer
with the Y92A-48D Protective Cover attached, which must
be taken into consideration before using the Y92A-48D
Protective Cover.
2. The hard protective cover prevents the set value from being altered due to accidental contact with the push type
thumbwheel switch.
Flush Mounting Adapter
Y92F-30
Mounting Track
PFP-100N, PFP-50N
PFP-100N2
16
7.3±0.15
4.5
4.5
15 25
25
10
25
1,000 (500)
(See note.)
10
35±0.3
27±0.15
35±0.3
25 *
15
1
25
25 15
25
25
10
1,000
27
24
1
10
Note: The values shown in parentheses are for the PFP-50N.
End Plate
PFP-M
Spacer
PFP-S
10
6.2
16
12
5
1.8
1
50
1.8
11.5
34.8
44.3
1.3
10 M4 x 8
pan head
screw
12
35.5 35.3
Digital Timer H5CN
4.8
16.5
29.2
1.5
Safety Precautions
Setting of Operating Time
!WARNING
The Y92S-20 Backup Battery used for the H5CN-X@NM is a lithium
battery (non-explosion-proof). Do not short-circuit the positive and
negative sides of the battery, recharge or disassemble the battery,
deform the battery under pressure, or dispose of the battery in fire.
Doing so may occasionally cause the battery to burst, ignite, or leak.
Use only the specified battery. Otherwise, the battery may leak or
burst, occasionally causing damage to the equipment or minor injury.
■ Precautions for Correct Use
Battery Connections when Using
Backup Power for Memory Protection
Always connect a battery when using models with backup power for
memory protection. Any 3-V battery can be used, but the backup
time will depend on the capacity of the battery. When using the Unit
for the first time after purchase, apply power and reset the Unit once
before using it. When power is turned ON for the first time, outputs
may be produced at the same time, so do not connect the output
terminals.
If a power interruption continues for 10 minutes or more when a
battery is not connected, the count value and displays may be
meaningless, and outputs may be produced unpredictably even if the
power supply recovers. If this happens, apply power to the reset input
once before using the Unit further. (The Unit can be used after
turning ON the reset input, regardless of whether a battery is
connected or not.)
Regular battery replacement (every 4 to 5 years) is recommended.
The life of the battery depends on the frequency of power failures.
Time Setting Range
Setting range
Models
0.001 to 9.999 s
H5CN-@Z@
0.01 to 99.99 s
H5CN-@A@
0.1 to 999.9 s
H5CN-@B@
1 s to 99 min 59 s
H5CN-@C@
1 min to 99 h 59 min
H5CN-@D@
1. The H5CN Timer is capable of reading the input data at any time
during normal operation. This means that the set time can be
changed during power application. This feature sets back the
output from the timer by temporarily setting the longer time or
quickens the output by setting the shorter time. During normal
operation, the set time may be accidentally changed by touching
a thumbwheel switch. To prevent this possibility, use the optional
Y92A-48@ Protective Cover.
2. When the set time is all zeroes (e.g., 000.0 s or 00 h 00 min),
there will be a momentary control output upon power application,
which can be used to check normal output. When changing the
set time during normal operation, pay special attention not to alter
the set value to this all zeroes.
3. When changing the set time while power is being supplied, an
inadequate push of the thumbwheel switches will display two
numbers in one digital display window, causing the operating time
to drift widely. Therefore, press the thumb-wheel switches surely.
Take particular care when the other three digits are all zeroes,
because the improper setting of the fourth switch to create four
zeroes will cause an instantaneous output.
Undesirable Setting
min
Y92S-20 or
equivalent 3-V battery
hours
sec
min
Changing unwanted
settings
Connection Methods
Conceivable
operating time
Y92S-20
To terminal No. 1
To terminal No. 4
P2CF-11
00h00min
(Instant output)
4. Take particular care with the H5CN-@Z@, which is capable of
setting in 1/1000th of a second because there is an error of
between 0.03 to 0.05 ms. (Repeat accuracy is 1 to 2 ms.)
Operation Examples
Y92S-20
To terminal No. 1
To terminal No. 4
5 min 30 s
• During Incremental Operation
If the set value is changed to a value higher than the currently
displayed present value, the timer will time out for the new set
value.
• During Decremental Operation
When the set value changes, the difference between the new set
value and old set value will be added or subtracted from the
present value.
Example:
P3GA-11
Old set value
200 s
New set value
->
Present value
(before changing setting)
160 s
100 s
Present set value
(after changing setting)
->
60 s
Digital Timer
H5CN
13
Power Supply
Leave the power supply OFF for at least 0.5 s before turning it back
ON (power supply reset).
Inputs and Outputs
• Do not apply voltage externally to input terminals A, C, and D.
• When using contacts for the reset input and gate input, use goldplated contacts with good contact reliability. Use gate input
contacts with short contact bounce (chattering).
Operation during Power Failures
• When Units without backup power for memory protection are used,
the timer status during momentary power failures is as shown in the
following diagrams.
A. Power Failure of 0.01 s Max.
m−2 m−1
m
m+1 m+2
Power failure
*Restarts from status before power failure.
B. Power Failure of 0.5 s Min.
m−2 m−1
m
1
2
3
Power failure
*Restarts from initial status after power reset.
C. Power Failure of 0.01 to 0.5 s Max.
m−2 m−1
m
1
m
m+1 m+2
2
3
Power failure
*Either A or B are undefined.
• Units with backup power for memory protection will restart from the
status before the power failure as shown in example A, regardless
of the length of time of the power failure.
14
Digital Timer H5CN
Warranty and Application Considerations
Warranty and Limitations of Liability
WARRANTY
OMRON's exclusive warranty is that the products are free from defects in materials and workmanship for a period of one year (or
other period if specified) from date of sale by OMRON.
OMRON MAKES NO WARRANTY OR REPRESENTATION, EXPRESS OR IMPLIED, REGARDING NON-INFRINGEMENT,
MERCHANTABILITY, OR FITNESS FOR PARTICULAR PURPOSE OF THE PRODUCTS. ANY BUYER OR USER
ACKNOWLEDGES THAT THE BUYER OR USER ALONE HAS DETERMINED THAT THE PRODUCTS WILL SUITABLY MEET
THE REQUIREMENTS OF THEIR INTENDED USE. OMRON DISCLAIMS ALL OTHER WARRANTIES, EXPRESS OR
IMPLIED.
LIMITATIONS OF LIABILITY
OMRON SHALL NOT BE RESPONSIBLE FOR SPECIAL, INDIRECT, OR CONSEQUENTIAL DAMAGES, LOSS OF PROFITS,
OR COMMERCIAL LOSS IN ANY WAY CONNECTED WITH THE PRODUCTS, WHETHER SUCH CLAIM IS BASED ON
CONTRACT, WARRANTY, NEGLIGENCE, OR STRICT LIABILITY.
In no event shall the responsibility of OMRON for any act exceed the individual price of the product on which liability is asserted.
IN NO EVENT SHALL OMRON BE RESPONSIBLE FOR WARRANTY, REPAIR, OR OTHER CLAIMS REGARDING THE
PRODUCTS UNLESS OMRON'S ANALYSIS CONFIRMS THAT THE PRODUCTS WERE PROPERLY HANDLED, STORED,
INSTALLED, AND MAINTAINED AND NOT SUBJECT TO CONTAMINATION, ABUSE, MISUSE, OR INAPPROPRIATE
MODIFICATION OR REPAIR.
Application Considerations
SUITABILITY FOR USE
OMRON shall not be responsible for conformity with any standards, codes, or regulations that apply to the combination of
products in the customer's application or use of the products.
Take all necessary steps to determine the suitability of the product for the systems, machines, and equipment with which it will
be used.
Know and observe all prohibitions of use applicable to this product.
NEVER USE THE PRODUCTS FOR AN APPLICATION INVOLVING SERIOUS RISK TO LIFE OR PROPERTY WITHOUT
ENSURING THAT THE SYSTEM AS A WHOLE HAS BEEN DESIGNED TO ADDRESS THE RISKS, AND THAT THE OMRON
PRODUCTS ARE PROPERLY RATED AND INSTALLED FOR THE INTENDED USE WITHIN THE OVERALL EQUIPMENT OR
SYSTEM.
Disclaimers
CHANGE IN SPECIFICATIONS
Product specifications and accessories may be changed at any time based on improvements and other reasons. Consult with
your OMRON representative at any time to confirm actual specifications of purchased product.
DIMENSIONS AND WEIGHTS
Dimensions and weights are nominal and are not to be used for manufacturing purposes, even when tolerances are shown.
ALL DIMENSIONS SHOWN ARE IN MILLIMETERS.
To convert millimeters into inches, multiply by 0.03937. To convert grams into ounces, multiply by 0.03527.
Cat. No. L052-E1-10
In the interest of product improvement, specifications are subject to change without notice.
OMRON Corporation
Industrial Automation Company
Industrial Devices and Components Division H.Q.
Industrial Control Components Department
Shiokoji Horikawa, Shimogyo-ku,
Kyoto, 600-8530 Japan
Tel: (81)75-344-7119/Fax: (81)75-344-7149
16
Printed in Japan
1203-0.5C (0696) (M)