0
登录后你可以
  • 下载海量资料
  • 学习在线课程
  • 观看技术视频
  • 写文章/发帖/加入社区
创作中心
发布
  • 发文章

  • 发资料

  • 发帖

  • 提问

  • 发视频

创作活动
H7CX-A4D

H7CX-A4D

  • 厂商:

    OMRON(欧姆龙)

  • 封装:

  • 描述:

    H7CX-A4D - Multifunction Preset Counter - Omron Electronics LLC

  • 数据手册
  • 价格&库存
H7CX-A4D 数据手册
Multifunction Preset Counter H7CX • Highly visible display with backlit negative transmissive LCD. • Programmable PV color to visually alert when output status changes (screw terminal block models). • Intuitive setting enabled using ergonomic up/down digit keys (4digit models) and DIP switch. • Configurable as 1-stage counter, 2-stage counter, total and preset counter, batch counter, dual counter, or tachometer. (Configurability varies with model.) • PNP/NPN switchable input. • Finger-safe terminals (screw terminal block models). • Meets a variety of mounting requirements: Screw terminal block models, and pin-style terminal models. • NEMA4/IP66 compliance. • Six-language instruction manual. Counters Contents Model Number Structure.............................................................. C-88 Ordering Information.................................................................... C-88 Specifications............................................................................... C-89 Connections................................................................................. C-93 Nomenclature .............................................................................. C-98 Dimensions .................................................................................. C-99 Precautions.................................................................................. C-103 Operating Procedures.................................................................. C-106 Setting Procedure Guide ....................................................... C-106 Operating Procedures (Counter Function) ............................ C-107 Operating Procedures (Tachometer Function) ...................... C-118 Operation in Configuration Selection Mode........................... C-124 Additional Information .................................................................. C-125 Multifunction Preset Counter H7CX C-87 Model Number Structure I Model Number Legend H7CX-A@@@@@@ 12 345 6 1. External connection None: Screw terminals 11: 11-pin socket 2. No. of digits None: 6 digits 4: 4 digits 3. Stage setting None: 1-stage setting U: Factory-set to 1-stage setting W: Factory-set to 2-stage setting 4. Output type None: Contact output or contact and transistor in combination S: Transistor output 5. Supply voltage/external power supply None: 100 to 240 VAC at 50/60 Hz with 12 VDC power supply D: 12 to 24 VDC without external power supply D1: 12 to 24 VDC or 24 VAC at 50/60 Hz with 12 VDC power supply 6. Case color None: Black G: Light gray (Munsell 5Y7/1): Produced upon request. Ordering Information I List of Models Supported configurations • 1-stage counter • 1-stage counter with total counter • 1-stage counter • 2-stage counter • 1-stage counter with total counter • 1-stage counter with batch counter • Dual counter (addition/subtraction) • Tachometer Screw terminal 1-stage 6 digits H7CX-A11@ 12 VDC Contact output 100 to 240 VAC 12 to 24 VDC/ 24 VAC Contact and transistor output Transistor output 100 to 240 VAC 12 to 24 VDC/ 24 VAC 100 to 240 VAC 12 to 24 VDC/ 24 VAC None Contact output Transistor output 12 to 24 VDC H7CX-A11 H7CX-A11D1 ----H7CX-A11S H7CX-A11SD1 ----4 digits H7CX-A114@ H7CX-A114 H7CX-A114D1 ----H7CX-A114S ------6 digits H7CX-A@ H7CX-A ------H7CX-AS --H7CX-AD H7CX-ASD 4 digits H7CX-A4@ H7CX-A4 ------H7CX-A4S --H7CX-A4D H7CX-A4SD ----H7CX-AU H7CX-AUD1 --H7CX-AUSD1 ----1-stage (See note.) 6 digits H7CX-AU@ 6 digits H7CX-AW@ H7CX-AW H7CX-AWD1 ----H7CX-AWS H7CX-AWSD1 --H7CX-AWSD ------------H7CX-A4WSD 2-stage 4 digits H7CX-A4W@ H7CX-A4W • 1-stage counter • 2-stage counter • 1-stage counter with total counter • 1-stage counter with batch counter • Dual counter (addition only) Sensor power supply Output type Supply voltage 11-pin socket Note: Can be used as a 2-stage counter. In this case, each output can be flexibly allocated to either stage 1 or 2. I Accessories (Order Separately) Name Flush Mounting Adapter (See note 1.) Waterproof Packing (See note 1.) Track Mounting/Front Connecting Socket Back Connecting Socket Hard Cover Soft Cover Mounting Track 50 cm (l) × 7.3 mm (t) 1 m (l) × 7.3 mm (t) 1 m (l) × 16 mm (t) End Plate Spacer 11-pin 11-pin, finger-safe type 11-pin 11-pin, finger-safe type Y92F-30 Y92S-29 P2CF-11 P2CF-11-E P3GA-11 P3GA-11 with Y92A-48G (See note 2.) Y92A-48 Y92A-48F1 PFP-50N PFP-100N PFP-100N2 PFP-M PFP-S Models Note: 1. Supplied with screw-terminal models (i.e., excluding H7CX-A11@/-A114@ models). 2. Y92A-48G is a finger-safe terminal cover attached to the P3GA-11 Socket. C-88 Multifunction Preset Counter H7CX Specifications I Ratings Item Classification Supported configurations Rated supply voltage (See note 1.) Power consumption H7CX-A4@ Preset counter 1-stage counter, 1-stage counter with total counter (selectable) 100 to 240 VAC (50/60 Hz), 12 to 24 VDC 100 to 240 VAC (50/60 Hz) 24 VAC (50/60 Hz)/12 to 24 VDC H7CX-A@ H7CX-A114@ H7CX-A11@ Operating voltage range 85% to 110% of rated supply voltage (90% to 110% at 12 VDC) Approx. 9.2 VA at 264 VAC Approx. 7.2 VA at 26.4 VAC Approx. 3.7 W at 12 VDC Flush mounting Screw terminals 0.5 N·m max. 7-segment, negative transmissive LCD; PV SV Digits 11.5-mm-high characters, red or 9-mm-high characters, red or green (programmable) green (programmable) 6-mm-high characters, green 4 digits (−999 to 9,999) SV range: 0 to 9,999 6 digits (−99,999 to 999,999) SV range: −99,999 to 999,999 (See note 2.) or 0 to 999,999 4 digits (−999 to 9,999) SV range: 0 to 9,999 6 digits (−99,999 to 999,999) SV range: −99,999 to 999,999 (See note 2.) or 0 to 999,999 11.5-mm-high characters, red 9-mm-high characters, red Flush mounting, surface mounting, or DIN track mounting 11-pin socket --- Mounting method External connections Terminal screw tightening torque Display Max. counting speed Input modes Input signals Input method 30 Hz or 5 kHz (selectable, ON/OFF ratio 1:1), common setting for CP1 and CP2 Increment, decrement, command, individual, and quadrature CP1, CP2, reset, and total reset No-voltage input/voltage input (switchable) No-voltage input ON impedance: 1 kΩ max. (Leakage current: 5 to 20 mA at 0 Ω) ON residual voltage: 3 V max. OFF impedance: 100 kΩ min. Voltage input High (logic) level: 4.5 to 30 VDC Low (logic) level: 0 to 2 VDC (Input resistance: approx. 4.7 kΩ) Minimum reset input signal width: 1 or 20 ms (selectable), common setting for all inputs External, manual, and automatic reset (internal according to C, R, P and Q mode operation) , N, F, C, R, K-1, P Q, A , 0.01 to 99.99 s Contact type: SPDT Transistor type: 1 transistor Contact output: 3 A at 250 VAC/30 VDC, resistive load (cosφ=1) Minimum applied load: 10 mA at 5 VDC (failure level: P reference value) , Transistor output: NPN open collector, 100 mA at 30 VDC Residual voltage: 1.5 VDC max. (approx. 1 V) Leakage current: 0.1 mA max. NEMA B300 Pilot Duty, 1/4 HP 3-A resistive load at 120 VAC, 1/3 HP 3-A resistive load at 240 VAC 12 VDC (±10%), 100 mA (except for H7CX-A@D models) Refer to Precautions for details. Yes Yes (0.001 to 9.999) Yes (rightmost 3 digits) 250 ms max. (Control output is turned OFF and no input is accepted during sensor waiting time.) EEPROM (overwrites: 100,000 times min.) that can store data for 10 years min. Operating: Storage: 25% to 85% Black (N1.5), light gray (Munsell 5Y7/1, produced upon request) Waterproof packing, flush mounting adapter None −10 to 55°C (−10 to 50°C if counters are mounted side by side) (with no icing or condensation) −25 to 65°C (with no icing or condensation) Yes (0.001 to 99.999) Yes (0.001 to 9.999) Yes (0.001 to 99.999) N, F, C, R, K-1, P Q, A, , K-2, D, L N, F, C, R, K-1, P Q, A , N, F, C, R, K-1, P Q, A, , K-2, D, L Reset input Reset system Output modes One-shot output time Output type Control output External power supply Key protection Prescaling function Decimal point adjustment Sensor waiting time Memory backup Ambient temperature Ambient humidity Case color Attachments Note: 1. Permissible ripple: 20% (p-p) max. 2. Only when the following modes are selected. Input mode: command, individual, or quadrature; output mode: K-2, D, or L Multifunction Preset Counter H7CX C-89 Counters I Ratings (contd.) Item Classification Supported configurations H7CX-A4W@ Preset counter H7CX-AW@ Preset counter/tachometer H7CX-AU@ 1-stage counter, 2-stage counter, 1-stage 1-stage counter, 2-stage counter, 1-stage counter with total counter, 1-stage counter with batch counter with total counter, 1-stage counter counter, dual counter (addition/subtraction), tachometer (selectable) with batch counter, dual counter (addition only) (selectable) 100 to 240 VAC (50/60 Hz), 12 to 24 VDC 100 to 240 VAC (50/60 Hz), 24 VAC (50/60 Hz)/12 to 24 VDC, 12 to 24 VDC 100 to 240 VAC (50/60 Hz), 24 VAC (50/60 Hz)/12 to 24 VDC Rated supply voltage (See note 1.) Operating voltage range Power consumption 85% to 110% of rated supply voltage (90% to 110% at 12 VDC) Approx. 9.2 VA at 264 VAC Approx. 7.2 VA at 26.4 VAC Approx. 3.7 W at 12 VDC Flush mounting Screw terminals 0.5 N·m max. 7-segment, negative transmissive LCD PV SV 11.5-mm-high characters, red or green (programmable) 6-mm-high characters, green 4 digits (−999 to 9,999) SV range: 0 to 9,999 CP1, CP2, reset 1, and reset 2 No-voltage input/voltage input (switchable) No-voltage input ON impedance: 1 kΩ max. (Leakage current: 5 to 20 mA at 0 Ω) ON residual voltage: 3 V max. OFF impedance: 100 kΩ min. Voltage input High (logic) level: 4.5 to 30 VDC Low (logic) level: 0 to 2 VDC (Input resistance: approx. 4.7 kΩ) 6 digits (−99,999 to 999,999 or 0 to 999,999 when using as Tachometer) SV range: −99,999 to 999,999 (See note 2.) or 0 to 999,999 9-mm-high characters, red or green (programmable) Mounting method External connections Terminal screw tightening torque Display Digits Input signals Input method Counter Max. counting speed Input mode Reset input Reset system Output modes One-shot output time 30 Hz or 5 kHz (selectable, ON/OFF ratio 1:1), common setting for CP1 and CP2 Increment, decrement, command, individual, and quadrature Minimum reset input signal width: 1 or 20 ms (selectable), common setting for all inputs External, manual, and automatic reset (internal according to C, R, P and Q mode operation) , N, F, C, R, K-1, P Q, A , 0.01 to 99.99 s ----------------Periodic measurement (Sampling period: 200 ms) 30 Hz or 10 kHz (selectable) 30 Hz: 0.01 to 30.00 Hz 10 kHz: 0.01 Hz to 10 kHz ±0.1% FS ±1 digit max. (at 23 ±5°C) HI-LO, AREA, HI-HI, LO-LO 0.1 to 99.9 s 0.0 to 99.9 s OFF/2/4/8 times H7CX-AU/-AUD1: SPDT and 1 transistor H7CX-AUSD1: 2 transistors (Output allocation possible) N, F, C, R, K-1, P Q, A, K-2, D, L, H , Tachometer Pulse measurement method Max. counting speed Measuring ranges Measuring accuracy Output modes Auto-zero time Startup time Average processing Output type H7CX-A4W/-AW/-AWD1: SPDT (OUT2) and SPST-NO (OUT1) H7CX-A4WSD/-AWS/-AWSD/-AWSD1: 2 transistors Contact output: 3 A at 250 VAC/30 VDC, resistive load (cosφ=1) Minimum applied load: 10 mA at 5 VDC (failure level: P reference value) , Transistor output: NPN open collector, 100 mA at 30 VDC Residual voltage: 1.5 VDC max. (approx. 1 V) Leakage current: 0.1 mA max. Control output NEMA B300 Pilot Duty, 1/4 HP 3-A resistive load at 120 VAC, 1/3 HP 3-A resistive load at 240 VAC External power supply Key protection Prescaling function Decimal point adjustment Sensor waiting time Memory backup Ambient temperature Ambient humidity Case color Attachments 12 VDC (±10%) 100 mA (except for H7CX-A@D models) Refer to Precautions for details. Yes Yes (0.001 to 9.999) Yes (rightmost 3 digits) 250 ms max. (Control output is turned OFF and no input is accepted during sensor waiting time.) EEPROM (overwrites: 100,000 times min.) that can store data for 10 years min. Operating: Storage: 25% to 85% Black (N1.5), light gray (Munsell 5Y7/1, produced upon request) Waterproof packing, flush mounting adapt- Waterproof packing, flush mounting adapter, labels for counter/tachometer DIP switch settings er −10 to 55°C (−10 to 50°C if counters are mounted side by side) (with no icing or condensation) −25 to 65°C (with no icing or condensation) Yes (0.001 to 99.999) Note: 1. Permissible ripple: 20% (p-p) max. 2. Only when the following modes are selected. - Input mode: command, individual, or quadrature; output mode: K-2, D, L, or H - Dual count calculating mode: SUB; output mode: K-2, D, L, or H in dual counter operation C-90 Multifunction Preset Counter H7CX I Characteristics item Insulation resistance Dielectric strength H7CX 100 MΩ min. (at 500 VDC) between current-carrying terminal and exposed non-current-carrying metal parts, and between non-continuous contacts 2,000 VAC, 50/60 Hz for 1 min between current-carrying metal parts and non-current-carrying metal parts 2,000 VAC (for 100 to 240 VAC), 50/60 Hz for 1 min between power supply and input circuit (1,000 VAC for 24 VAC/ 12 to 24 VDC) 1,000 VAC (for H7CX-@SD/-@SD1), 50/60 Hz for 1 min between control output, power supply, and input circuit (2,000 VAC for models other than H7CX-@SD/-@SD1) 1,000 VAC, 50/60 Hz for 1 min between non-continuous contacts 3 kV (between power terminals) for 100 to 240 VAC, 1 kV for 24 VAC/12 to 24 VDC and 12 to 24 VDC 4.5 kV (between current-carrying terminal and exposed non-current-carrying metal parts) for 100 to 240 VAC, 1.5 kV for 24 VAC/12 to 24 VDC and 12 to 24 VDC ±1.5 kV (between power terminals) for 100 to 240 VAC and 24 VAC/12 to 24 VDC, ±480 V for 12 to 24 VDC ±600 V (between input terminals) Square-wave noise by noise simulator (pulse width: 100 ns/1 µs, 1-ns rise) Destruction: 15 kV Malfunction: 8 kV Destruction: 10 to 55 Hz with 0.75-mm single amplitude, four cycles each in three directions (8 minutes per cycle) Malfunction: 10 to 55 Hz with 0.35-mm single amplitude, four cycles each in three directions (8 minutes per cycle) Destruction: 294 m/s2 each in three directions Malfunction: 98 m/s2 each in three directions Mechanical: 10,000,000 operations min. Electrical: 100,000 operations min. (3 A at 250 VAC, resistive load) See Life-test Curve on page 92. UL508/Listing, CSA C22.2 No. 14, conforms to EN61010-1 (Pollution degree 2/overvoltage category II) Conforms to VDE0106/P100 (finger protection). (EMI) Emission Enclosure: Emission AC mains: (EMS) Immunity ESD: EN61326 EN55011 Group 1 class A EN55011 Group 1 class A EN61326 EN61000-4-2: 4 kV contact discharge (level 2) 8 kV air discharge (level 3) Immunity RF-interference: EN61000-4-3: 10 V/m (Amplitude-modulated, 80 MHz to 1 GHz) (level 3); 10 V/m (Pulse-modulated, 900 MHz ±5 MHz) (level 3) Immunity Conducted Disturbance: EN61000-4-6: 10 V (0.15 to 80 MHz) (level 3) Immunity Burst: EN61000-4-4: 2 kV power-line (level 3); 1 kV I/O signal-line (level 4) Immunity Surge: EN61000-4-5: 1 kV line to lines (power and output lines) (level 2); 2 kV line to ground (power and output lines) (level 3) Immunity Voltage Dip/Interruption EN61000-4-11: 0.5 cycle, 100% (rated voltage) Panel surface: IP66 and NEMA Type 4 (indoors) (See note 2.) Approx. 140 g Impulse withstand voltage Noise immunity Static immunity Vibration resistance Shock resistance Life expectancy Approved safety standards (See note 1.) EMC Degree of protection Weight Note: 1. To meet UL listing requirements with the H7CX-A11@ models, an OMRON P2CF-11-@ or P3GA-11 Socket must be mounted on the H7CX. Otherwise, H7CX-A11@ models are considered to meet UL508 recognition requirements. 2. A waterproof packing is necessary to ensure IP66 waterproofing between the H7CX and installation panel. Multifunction Preset Counter H7CX C-91 Counters I Life-test Curve (Reference Values) Resistive Load 1,000 Inductive Load 1,000 No. of operations (×103) No. of operations (×103) 700 500 700 500 300 300 30 VDC (L/R=7 ms) 30 VDC (cosφ=1) 100 70 50 0 250 VAC (cosφ=1) 100 70 50 250 VAC cosφ=0.4 1 2 3 4 0 1 2 3 4 Load current (A) Reference: A current of 0.15 A max. can be switched at 125 VDC (cosφ=1) and current of 0.1 A max. can be switched if L/R=7 ms. In both cases, a life of 100,000 operations can be expected. The minimum applicable load is 10 mA at 5 VDC (failure level: P). Load current (A) I Inrush Current (Reference Values) Model H7CX-A11/-AW H7CX-AD Voltage 100 to 240 VAC 12 to 24 VDC Applied voltage Inrush current (peak value) 264 VAC 26.4 VDC 5.8 A 10.4 A 6.0 A Time 0.7 ms 1.2 ms 1.2 ms H7CX-A11D1/-AWD1 24 VAC/12 to 24 VDC 26.4 VAC C-92 Multifunction Preset Counter H7CX Connections I Block Diagram Output circuit (Basic insulation) Input circuit Internal control circuit (Basic insulation) Power supply circuit Display circuit Key switch circuit Note: All models except for H7CX-@D (models with 12 to 24-VDC power supplies) have basic insulation. I I/O Functions Using as a Counter Inputs CP1, CP2 • In general (except for dual counter mode) Reads counting signals Increment, decrement, command, individual, and quadrature inputs accepted. • When used as a dual counter Reads CP1 count signals with CP1 input and CP2 count signals with CP2 input. Increment signals can be input. • In general (except for dual counter mode) Resets present value and outputs (OUT2 when using the batch counter). (See note 1.) Counting cannot be performed during reset/reset 1 input. The reset indicator is lit during reset input. • When used as a dual counter Resets the CP1 present value (to 0). Counting for CP1 input cannot be performed during reset 1 input. The reset indicator is lit during reset 1 input. • When used as a 1-stage/2-stage counter Does not operate (Not used). • When used as a total and preset counter Resets the total count value. Holds the total count value at 0 during total reset input. • When used as a batch counter Resets the batch count value and batch output (OUT1). Holds the batch count value at 0 during reset 2 input. • When used as a dual counter Resets the CP2 present value. Counting for CP2 input cannot be performed during reset 2 input. Outputs take place according to designated output mode when corresponding preset is reached. Reset or Reset 1 Total Reset or Reset 2 (See note 2.) Outputs OUT1, OUT2 Note: 1. In increment mode or increment/decrement mode, the present value returns to 0; in decrement mode, the present value returns to the set value with 1-stage models, and returns to set value 2 with 2-stage models. 2. The reset indicator will not be lit when the total reset or reset 2 input is ON. Using as a Tachometer Inputs CP1, CP2 Reset 1, Reset 2 Outputs OUT1, OUT2 Reads counting signals. (CP2 input is not used.) Holds the measurement value and outputs. (Reset 2 input is not used.) The reset indicator is lit during hold. Outputs signals according to the specified output mode when a set value is reached. Multifunction Preset Counter H7CX C-93 Counters (See note.) I Terminal Arrangement Confirm that the power supply meets specifications before use. H7CX-A/-A4 1-stage Contact Output Total reset Reset CP2 CP1 H7CX-AD/-A4D 1-stage Contact Output Total reset 10 Unused Reset CP2 8 Unused 0V 6 Unused 0V (−) Sensor, etc. 6 7 8 Unused 9 10 Unused 7 (+) 12 VDC 11 External power supply 12 13 11 12 CP1 9 4 OUT 13 1 2 3 4 OUT 5 1 (−) 2 (+) 3 5 Note: Terminals 1 and 6 are connected internally. H7CX-AS/-A4S 1-stage Transistor Output Total reset Reset CP2 CP1 H7CX-ASD/-A4SD 1-stage Transistor Output Total reset 10 Unused Reset CP2 8 Unused 0V 6 Unused 0V (−) Sensor, etc. 6 7 8 Unused 9 10 Unused 7 (+) 12 VDC 11 External power supply 12 13 11 12 CP1 9 4 OUT 13 1 2 3 4 OUT 5 1 (−) 2 (+) 3 5 Note: Terminals 1 and 6 are connected internally. H7CX-A11/-A114/-A11D1/-A114D1 1-stage Contact Output Reset CP1 CP2 Total reset H7CX-A11S/-A114S/-A11SD1 1-stage Transistor Output Reset CP1 Internal circuit 567 4 0V 8 9 10 3 2 1 11 CP2 Total reset Internal circuit 567 4 0V 8 9 10 3 2 1 11 (−) Sensor, etc. (−) Sensor, etc. (+) 12 VDC (+) OUT (−) (+) 12 VDC External power supply External power supply OUT (−) (+) Note: Do not connect unused terminals as relay terminals. C-94 Multifunction Preset Counter H7CX H7CX-AW/-A4W/-AWD1 2-stage Contact Output Reset 1 Reset 2 CP2 CP1 H7CX-AWS/-AWSD1 2-stage Transistor Output Reset 1 Reset 2 10 CP2 8 0V (−) Sensor, etc. 0V 7 8 9 10 (−) Sensor, etc. 12 VDC 6 6 7 External power supply 11 12 13 OUT1 External power supply 11 12 13 OUT1 1 2 3 4 OUT2 5 1 2 3 4 OUT2 5 (−) (+) (−) (+) H7CX-AWSD/-A4WSD 2-stage Transistor Output Reset 1 Reset 2 CP2 CP1 H7CX-AUSD1 1 or 2-stage Transistor Output Reset 1 Reset 2 CP2 CP1 0V 0V 6 Unused 7 8 9 10 (−) Sensor, etc. 6 7 8 9 10 (+) 12 13 OUT1 12 VDC 11 11 External power supply 12 13 OUT1 or 2 1 (−) 2 (+) 3 4 OUT2 5 1 2 3 4 5 OUT 1 or 2 (−) (+) Note: 1. Terminals 1 and 6 are connected internally. 2. Do not connect unused terminals as relay terminals. Note: Each output can be flexibly allocated to either stage 1 or 2 in function selection mode. H7CX-AU/-AUD1 1-stage Contact, 1-stage Transistor Output Reset 1 Reset 2 CP2 CP1 0V (−) Sensor, etc. 6 7 8 9 10 (+) 12 VDC External power supply 11 12 13 OUT1 or 2 1 2 3 4 5 OUT 1 or 2 (−) (+) Note: Each output can be flexibly allocated to either stage 1 or 2 by setting in function selection mode. Multifunction Preset Counter H7CX C-95 Counters (+) 12 VDC (+) CP1 9 I Input Circuits CP1, CP2, Reset/Reset 1, and Total Reset/Reset 2 Input +14 V 1 kΩ IN Internal circuit Note: The circuit shown above is for no-voltage input (NPN input). I Input Connections The inputs of the H7CX are no-voltage (short-circuit or open) inputs or voltage inputs. No-voltage Inputs (NPN Inputs) Open Collector PLC or sensor Total reset/reset 2 input Voltage Output Sensor Contact Input Reset/reset 1 input Reset/reset 1 input Reset/reset 1 input 0V 0V 0V CP2 input CP1 input H7CX-A@ H7CX-A11@ Input 6 3 7 7 8 5 9 6 10 4 H7CX-A@ H7CX-A11@ 6 3 7 7 8 5 9 6 10 4 H7CX-A@ H7CX-A11@ 6 3 7 7 8 5 9 6 10 4 Operates when the transistor turns ON. Operates when the transistor turns ON. Operates when the contact turns ON. No-voltage Input Signal Levels No-contact input Short-circuit level Transistor ON Residual voltage: 3 V max. Impedance when ON: 1 KΩ max. (The leakage current is 5 to 20 mA when the impedance is 0 Ω.) Open level Transistor OFF Impedance when OFF: 100 KΩ min. Contact input Use contact which can adequately switch 5 mA at 10 V. Maximum applicable voltage: 30 VDC max. DC Two-wire Sensor 0V Reset/reset 1 input H7CX-A@ H7CX-A11@ 6 3 7 7 8 5 9 6 10 4 Operates when the transistor turns ON. Applicable Two-wire Sensor Leakage current:1.5 mA max. Switching capacity:5 mA min. Residual voltage:3 VDC max. Operating voltage:10 VDC C-96 Multifunction Preset Counter H7CX Total reset/reset 2 input CP2 input CP1 input Input Total reset/reset 2 input Total reset/reset 2 input CP2 input CP1 input CP2 input CP1 input Input Input Voltage Inputs (PNP Inputs) No-contact Input (NPN Transistor) Sensor No-contact Input (PNP Transistor) Sensor Contact Input Total reset/reset 2 input Total reset/reset 2 input Reset/reset 1 input Reset/reset 1 input Reset/reset 1 input CP2 input CP2 input CP1 input CP1 input CP2 input H7CX-A@ H7CX-A11@ 6 3 7 7 8 5 9 6 10 4 H7CX-A@ H7CX-A11@ 6 3 7 7 8 5 9 6 10 4 H7CX-A@ H7CX-A11@ 6 3 7 7 8 5 9 6 CP1 input Input Input Input 10 4 Operates when the transistor turns OFF. Operates when the transistor turns ON. Operates when the contact turns ON. Voltage Input Signal Levels High level (Input ON): Low level (Input OFF): Maximum applicable voltage: Input resistance: 4.5 to 30 VDC 0 to 2 VDC 30 VDC max. Approx. 4.7 kΩ Multifunction Preset Counter H7CX C-97 Counters 0V 0V 0V Total reset/reset 2 input Nomenclature Indicators A Reset Indicator (Orange) Lit when the reset input (1) or reset key is ON. B Key Protection Indicator (Orange) C Control Output Indicator (Orange) OUT: One stage OUT1, OUT2: Two stages D Total Count Indicator Lit when the total count value is displayed. E Batch Indicator Lit when the batch count value is displayed. F Set Value 1, 2 Stage Indicator G Present Value (Main Display) Character height: 11.5 mm (6-digit: 9mm) H Set Value (Sub-display) Character height: 6 mm 1 2 3 4 5 6 9 Operation Keys 7 8 11 12 10 Front view of 4-digit model I Mode Key Used to switch mode and setting items. J Reset Key The operation of the reset function depends on the configuration selected as shown in the table below. K Up Keys: 1 to 4 (6-digit models: 1 to 6) L Down Keys: 1 to 4 Switches M Key Protect Switch 1 2 3 4 5 6 9 (Factory setting) OFF ON 7 8 N DIP Switch 11 10 Front view of 6-digit model 13 14 Reset Operation by Reset Key Configuration 1-stage/2-stage counter Reset operation Resets the present value and outputs. Total and preset • Resets the present value and outputs. counter • When the total count value is displayed, resets the present value, the total count value, and outputs. Batch counter • Resets the present value and OUT2. • When the batch count value is displayed, resets the present value, the batch count value, and outputs. Resets the CP1 present value, CP2 present value, dual count value, and outputs. Maintains the measured value and outputs (hold function). Dual counter Tachometer C-98 Multifunction Preset Counter H7CX Dimensions Note: All units are in millimeters unless otherwise indicated. I Counter (without Flush Mounting Adapter) Screw-terminal Models with External Power Supplies (Flush Mounting) Counters 6 100 44.8×44.8 • H7CX-A • H7CX-AS • H7CX-A4 • H7CX-A4S • H7CX-AW • H7CX-AWS • H7CX-A4W • H7CX-AWD1 • H7CX-AWSD1 • H7CX-AU • H7CX-AUD1 • H7CX-AUSD1 48×48 Note: M3.5 terminal screw (effective length: 6 mm) Screw-terminal Models without External Power Supplies (Flush Mounting) • H7CX-AD • H7CX-ASD • H7CX-A4D • H7CX-A4SD • H7CX-AWSD • H7CX-AWSD 48×48 6 64 44.8×44.8 Note: M3.5 terminal screw (effective length: 6 mm) 11-pin Socket Models (Flush Mounting/Surface Mounting) • H7CX-A11 • H7CX-A11S • H7CX-A11D1 • H7CX-A11SD1 • H7CX-A114 • H7CX-A114S • H7CX-A114D1 48×48 6 72.5 14.4 44.8×44.8 Multifunction Preset Counter H7CX C-99 I Dimensions with Flush Mounting Adapter Screw-terminal Models with External Power Supplies (Provided with Adapter and Waterproof Packing) • H7CX-A • H7CX-AS • H7CX-A4 • H7CX-A4S • H7CX-AW • H7CX-AWS • H7CX-A4W • H7CX-AWD1 • H7CX-AWSD1 • H7CX-AU • H7CX-AUD1 • H7CX-AUSD1 Panel Cutouts Panel cutouts are as shown below. (according to DIN43700). Y92S-29 (provided) Waterproof Packing Panel Y92F-30 (provided) Flush Mounting Adapter 60 min. 45+0.6 −0 45+0.6 −0 60 min. 15 min. 58 (51) 48 7.5 98.5 Screw-terminal Models without External Power Supplies (Provided with Adapter and Waterproof Packing) • H7CX-AD • H7CX-ASD • H7CX-A4D • H7CX-A4SD • H7CX-AWSD • H7CX-A4WSD Y92S-29 (provided) Waterproof Packing Panel Y92F-30 (provided) Flush Mounting Adapter Note: 1. The mounting panel thickness should be 1 to 5 mm. 2. To allow easier operability, it is recommended that Adapters are mounted so that the gap between sides with hooks is at least 15 mm (i.e., so that the panel cutout interval is at least 60 mm). 3. It is possible to mount counters side by side, but only in the direction without the hooks. If they are mounted side-by-side, water-resistant specifications cannot be ensured. 58 (51) n side by side mounting A 48 7.5 62.5 A = (48n − 2.5)+1 0 With Y92A-48F1 attached. A = {48n−2.5 + (n−1) x 4}+1 0 With Y92A-48 attached. A = (51n−5.5)+1 0 11-pin Socket Models (Adapter and Waterproof Packing Ordered Separately) • H7CX-A11 • H7CX-A11S • H7CX-A11D1 • H7CX-A11SD1 • H7CX-A114 • H7CX-A114S • H7CX-A114D1 Y92S-29 (order separately) Waterproof Packing Panel Y92F-30 (order separately) Flush Mounting Adapter 58 (51) P3GA-11 (order separately) Back Connecting Socket 48 7.5 98.7 I Dimensions with Front Connecting Socket H7CX -A11@ 112 109.7 P2CF-11 Note: These dimensions vary with the kind of DIN track (reference value). C-100 Multifunction Preset Counter H7CX I Accessories (Order Separately) Note: All units are in millimeters unless otherwise indicated. Track Mounting/Front Connecting Socket P2CF-11 Eleven, M3.5 x 7.5 sems 7.8 3 4.5 70 max. Two, 4.5-dia. holes 4 50 max. 31.2 max. 35.4 Terminal Arrangement/ Internal Connections (Top View) Surface Mounting Holes Two, 4.5 dia. or two, M4 40±0.2 Note: Track mounting is also possible. P2CF-11-E (Finger Safe Terminal Type) Conforming to VDE0106/P100 Eleven, M3.5 x 7.5 sems 7.8 5 3 70 max. 1.2 Two, 4.5-dia. holes 4 40±0.2 50 max. 30 31.2 max. 35.4 4.5 Back Connecting Socket P3GA-11 27 dia. Terminal Arrangement/ Internal Connections (Bottom View) 25.6 45 45 4.5 16.3 6.2 Note: Finger protection can be ensured by using in combination with the Y92A-48G Terminal Cover. Finger Safe Terminal Cover Conforming to VDE0106/P100 Y92A-48G (Attachment for P3GA-11 Socket) 34 Twelve, 6.4-dia. holes 47.7 x 47.7 48 x 48 16.5 24.6 27.6 47.4 Multifunction Preset Counter H7CX C-101 Counters Hard Cover Y92A-48 Soft Cover Y92A-48F1 Note: 1. Depending on the operating environment, the condition of the Soft Cover may deteriorate, and it may shrink or become harder. Therefore, it is recommended that the Soft Cover is replaced regularly. 2. The H7CX’s panel surface is water-resistive (conforming to IP66) and so even if drops of water penetrate the gaps between the keys, there will be no adverse effect on internal circuits. If, however, there is a possibility of oil being present on the operator’s hands, use the Soft Cover. The Soft Cover ensures protection equivalent to IP54F against oil. Do not, however, use the H7CX in locations where it would come in direct contact with oil. Flush Mounting Adapter (provided with screw-terminal models) Y92F-30 Waterproof Packing (provided with screw-terminal models) Y92S-29 Mounting Track PFP-100N, PFP-50N PFP-100N2 7.3±0.15 4.5 35±0.3 15 25 10 25 25 * 25 1,000 (500) 10 (see note) 27±0.15 1 16 4.5 35±0.3 15 25 10 25 1,000 25 10 25 15 27 24 1 29.2 1.5 Note: The values shown in parentheses are for the PFP-50N. End Plate PFP-M 10 6.2 1.8 Spacer PFP-S 5 16 12 1 50 1.8 35.5 35.3 44.3 34.8 11.5 10 M4 x 8 pan head screw 1.3 4.8 16.5 C-102 Multifunction Preset Counter H7CX Precautions !Caution Do not use the product in locations subject to flammable or explosive gases. Doing so may result in explosion. The service life of the output relays depends on the switching capacity and switching conditions. Consider the actual application conditions and use the product within the rated load and electrical service life. Using the product beyond its service life may result in contact deposition or burning. Do not disassemble, repair, or modify the product. Doing so may result in electric shock, fire, or malfunction. Do not allow metal objects or conductive wires to enter the product. Doing so may result in electric shock, fire, or malfunction. + I Transistor Output The transistor output of the H7CX is isolated from the internal circuitry by a photocoupler, so the transistor output can be used as both NPN and PNP output. Counters NPN output PNP output Load Load + Power for load Power for load I External Power Supply The capacity of the external power supply is 100 mA at 12 V. When using a 24 VAC/12 to 24 VDC power supply, reduce the load with the power supply voltage, as shown in the following diagram (DC power supplies only). The diode connected to the collector of the output transistor is used to absorb inverted voltage that is generated when an inductive load is connected to the H7CX. Counter (DC v ltage Load current (mA) 100 ppl only) + Inductive load Power for load I Changing the Set Values When changing the set value during operation, because the H7CX uses a constant read-in system, output will turn ON if the set value is equal to the present value. I Operation with a Set Value and Present Value of 0 20 10.8 15 If the set value and present value are both 0, output will turn ON. Output will turn OFF during reset. C) Power pply vol age I Power Supplies When turning the power ON and OFF, input signal reception is possible, unstable, or impossible as shown in the diagram below. Power supply ON OFF 200 ms 0 to 90 ms 5 ms I Using the Prescaling Function Observe the following points when setting a prescale value. • Set the set value to a value less than {Maximum countable value − Prescale value}. Example: If the prescale value is 1.25 and the counting range is 0.000 to 999.999, set the set value to a value less than 998.749 (= 999.999 − 1.25). 0 to 1 s Impossible Unstable Input Impossible Possible Unstable • If the set value is set to a value greater than this, output will not turn ON. Note: Output will turn ON, however, if a present value overflow occurs (FFFFFF or FFFF). • Setting the prescale value incorrectly may result in incorrect counting operation. Be sure to set the prescale value correctly. Turn the power ON and OFF using a relay with a rated capacity of 10 A minimum to prevent contact deterioration due to inrush current caused by turning the power ON and OFF. Apply the power supply voltage through a relay or switch in such a way that the voltage reaches a fixed value immediately, otherwise they may not be reset or a counter error may result. Be sure that the capacity of the power supply is large enough, otherwise the counter may not start due to inrush current (reference value: approx. 10 A, 1.2 ms at 26.4 VAC) that may flow for an instant when the counter is turned ON. Make sure that the fluctuation of the supply voltage is within the permissible range. Make sure that the voltage applied is within the specified range, otherwise the internal elements of the counter may be damaged. I DIP Switch Setting Ensure that the power is turned OFF before changing DIP switch settings. Changing DIP switch settings with the power turned ON may result in electric shock due to contact with terminals subject to high voltages. I Power Failure Backup All data is stored in the EEPROM when there is power failure. The EEPROM can be overwritten more than 100,000 times. EEPROM is overwritten when the power is turned OFF or when settings are changed. Multifunction Preset Counter H7CX C-103 I Self-diagnostic Function The following displays will appear if an error occurs. Main display Sub-display Error Present value underflow (See note 3.) Output status No change Correction method Either press the reset key or turn ON reset input. Set value after reset No change No change -----(----) (See notes 1 and 2.) No change ffffff (ffff) (See notes 1 and 2.) e1 e2 e2 Not lit Not lit sum Present value overflow (See note 4.) No change Either press the reset key or turn ON reset input. (See note 5.) No change CPU Memory error (RAM) Memory error (EEP) (See note 6.) OFF OFF OFF Either press the reset key or reset the No change power supply. Reset the power supply. No change Reset to the factory settings using the 0 reset key. Note: 1. 2. 3. 4. The display for 4-digit models is given in parentheses. Display flashes (1-second cycles). Occurs when the present value or the total count value goes below −99,999 (−999 with 4-digit models). Occurs when the present value (or measurement value) reaches 999,999 (9,999 with 4-digit models) under the following conditions: • The output mode is K-2, D, L, or H. • The H7CX is set for dual counter or tachometer operation. 5. Except when the H7CX is set for tachometer operation. 6. Includes the case where the EEPROM has reached its overwrite lifetime. I Response Delay Time When Resetting (Transistor Output) The following table shows the delay from when the reset signal is input until the output is turned OFF. (Reference values) I Wiring Wiring input lines in the same conduit as power lines or other highvoltage lines may result in malfunction due to noise. Wire the input lines separately, away from lines carrying high-voltages. In addition, make the input wiring as short as possible and use shield lines or metal wiring conduits. Pay attention to terminal polarity to ensure correct wiring. Minimum reset signal width 1 ms 20 ms Output delay time 0.8 to 1.2 ms 15 to 25 ms I Mounting Tighten the two mounting screws on the Adaptor. Tighten them alternately, a little at a time, so as to keep them at an equal tightness. The H7CX’s panel surface is water-resistive (conforming to NEMA 4 and IP66). In order to prevent the internal circuit from water penetration through the space between the timer and operating panel, attach a waterproof packing between the timer and installation panel and secure the waterproof packing with the Y92F-30 Flush-mounting Adapter. 0.5 to 1 mm I Output Delay Time The following table shows the delay from when the present value passes the set value until the output is produced. Actual measurements in N and K-2 modes. Control output type Maximum counting speed Contact output Transistor output 30 Hz 5 kHz 30 Hz 5 kHz (Reference values) Output delay time 16.5 to 24.0 ms 3.7 to 5.6 ms 12.0 to 20.0 ms 0.2 to 0.55 ms It is recommended that the space between the screw head and the adapter should be 0.5 to 1 mm. Note: The above times may vary slightly depending on the mode or operating conditions. I Maximum Counting Speed for Batch Counter The maximum counting speed for batch counter operation is 5 kHz. The batch counter counts the number of times the count reaches the set value. C-104 Multifunction Preset Counter H7CX I Operating Environment • Use the product within the ratings specified for submerging in water and exposure to oil. • Do not use the product in locations subject to vibrations or shocks. Using the product in such locations over a long period may result in damage due to stress. • Do not use the product in locations subject to dust, corrosive gases, or direct sunlight. • Separate the input signal devices, input signal cables, and the product from the source of noise or high-tension cables producing noise. • Separate the product from the source of static electricity when using the product in an environment where a large amount of static electricity is produced (e.g., forming compounds, powders, or fluid materials being transported by pipe). • Organic solvents (such as paint thinner), as well as very acidic or basic solutions might damage the outer casing of the H7CX. • Use the product within the ratings specified for temperature and humidity. • Do not use the product in locations where condensation may occur due to high humidity or where temperature changes are severe. • Store at the specified temperature. If the H7CX has been stored at a temperature of less than -10°C, allow the H7CX to stand at room temperature for at least 3 hours before use. • Leaving the H7CX with outputs ON at a high temperature for a long time may hasten the degradation of internal parts (such as electrolytic capacitors). Therefore, use the product in combination with relays and avoid leaving the product as long as more than 1 month with the output turned ON. X2/b T/a X1/a X1/a T X1 X X2 Auxiliary relay (e.g., MY Relay) • The load current must be within the rated current. I Insulation • Specifications call for basic insulation between the power supply and input terminals, between the power supply and output terminals, and between the input and output terminals. (The H7CX-A@D is not insulated between the power supply and input terminals.) • Input and output terminals are connected to devices without exposed charged parts. • Input and output terminals are connected to devices with basic insulation that is suitable for the maximum operating voltage. Multifunction Preset Counter H7CX C-105 Counters Operating Procedures I Setting Procedure Guide Setting for Counter Operation (1-stage/2-stage Counter, Total and Preset Counter, Batch Counter, Dual Counter) When Using Basic Settings Only Basic Settings • • • • • • Counting speed (30 Hz, 5 kHz) Input mode (UP, DOWN) Output mode (N, F, C, K-1) One-shot output time (0.5 s, 0.05 s)(See note 2.) Reset input signal width (20 ms, 1 ms) NPN/PNP input mode (NPN, PNP) The settings can be performed easily with the DIP switch. ➡ For details on the setting methods, refer to page 21. 1 ON 2 3 4 5 6 7 8 OFF When Using Settings Other than the Above All the functions can be set with the operation keys. ➡ For details on the setting methods, refer to page 22. Other Settings • Input mode (UP/DOWN A, UP/DOWN B, UP/DOWN C) • Output mode (R, P, Q, A, K-2, D, L, H) • One-shot output time (except for 0.5 s and 0.05 s) (See note 2.) When Using Advanced Functions Settings for advanced functions other than the basic settings above can be performed with the operation keys. ➡ For details on the setting methods, refer to page 22. • • • • • • • Advanced Functions Dual count calculating mode Output 1 time (for 2-stage counter) Decimal point position Prescale value Display color Output allocation Key protect level Note: 1. At the time of delivery, the H7CX is set to the 1-stage counter (2-stage counter for H7CX-AW@/-A4W@ models) configuration. 2. Set to output 2 time when using as a 2-stage counter or batch counter. Setting for Tachometer Operation When Using Basic Settings Only Basic Settings • • • • Counting speed (30 Hz, 10 kHz) Output mode (HI-LO, AREA, HI-HI, LO-LO) Average processing (OFF, 2, 4, 8 times) NPN/PNP input mode (NPN, PNP) The settings can be performed easily with the DIP switch. ➡ For details on the setting methods, refer to page 33. 1 ON 2 3 4 5 6 7 8 OFF When Using Advanced Functions Settings for advanced functions other than the basic settings above can be performed with the operation keys. ➡ For details on the setting methods, refer to page 34. Advanced Functions • • • • • • • Decimal point position Prescale value Auto-zero time Startup time Display color Output allocation Key protect level Note: At the time of delivery, the H7CX is set to the 2-stage counter (1-stage counter for H7CX-AU@ models) configuration. C-106 Multifunction Preset Counter H7CX I Operating Procedures (Counter Function) Settings for Basic Operations Settings for basic functions can be performed with just the DIP switch. Be sure to set pin 1 to ON. 1 ON 2 3 4 5 6 7 8 OFF Note: All of the pins are factory-set to OFF. Item 1 2 3 4 5 6 7 8 One-shot output time (See note.) Reset input signal width NPN/PNP input mode 0.5 s DIP switch settings enable/disable Counting speed Input mode Output mode OFF Disabled 30 Hz ON Enabled 5 kHz UP (increment) DOWN (decrement) Refer to the table on the right. 0.05 s 1 ms PNP Pin 4 OFF ON OFF 20 ms NPN ON Pin 5 OFF OFF ON ON N F C K-1 Output mode Note: Set to one-shot output 2 time when using as a 2-stage counter or batch counter. Easy Confirmation of Switch Settings Using Indicators The ON/OFF status of the DIP switch pins can be confirmed using the front display. For details, refer to page 124. Note: 1. Be sure to set pin 1 of the DIP switch to ON. If it is set to OFF, the DIP switch settings will not be enabled. 2. Changes to DIP switch settings are enabled when the power is turned ON. 3. When setting input modes, output modes, or output times that cannot be set with the DIP switch, all of the settings have to be made using the operation keys. For details on the setting methods, refer to page 108. When making settings using the operation keys, be sure to set pin 1 of the DIP switch to OFF. Switching to Total and Preset Counter, Batch Counter, and Dual Counter Operation (See note.) The H7CX is factory-set to the 1-stage counter (2-stage counter for H7CX-AW@/A4W@ models) configuration. To change to a different configuration, use the procedure shown on the right. For details, refer to page 39. Note: This includes changing to the 2stage counter (or 1-stage counter) configuration. Power ON Configuration selection mode Run mode Hold down for 1 s min. (See note.) MODE + 1 Note: The MODE key must be pressed before the Select the configuration using the and keys ( 1 key. key with 6-digit models). (1-stage counter) (2-stage (Total and counter) preset counter) (Batch counter) (Dual counter) (Tachometer) Note: The configurations that can be selected vary with the model. Advanced-Function Settings After making DIP switch settings for basic operations, advanced functions (see note) can be added using the operation keys. For details, refer to page 22. Note: Advanced functions consist of the dual count calculating mode, output 1 time (for 2-stage counter), decimal point position,prescale value, display color, output allocation, and key protect level. Multifunction Preset Counter H7CX (Counter Function) C-107 Counters Settings for All Functions Note: At the time of delivery, the H7CX is set to the 1-stage counter (2-stage counter for H7CX-AW@/-A4W@ models) configuration. When using as a 2-stage (or 1-stage) counter, total and preset counter, batch counter, or dual counter, switch to the configuration using the procedure given on page 124. Settings that cannot be performed with the DIP switch are performed with the operation keys. Power ON For details on operations in run mode, refer to page 25. Run mode Note: 1. If the mode is switched to the function setting mode during operation, operation will continue. 2. Changes made to settings in function setting mode are enabled for the first time when the mode is changed to run mode. Also, when settings are changed, the counter is reset (present value initialized and output turned OFF) on returning to run mode. See note 1. 3 s min. See note 2. 3 s min. The characters displayed in reverse video are the default settings. When performing settings with operation keys only, set pin1 of the DIP switch to OFF (factory setting). If pin 1 of the DIP switch is set to ON, the setting items indicated by will not be displayed. Set each setting item using the r r keys. ( r key only for 6-digit models) Note 3: See note 3. Input mode See note 4. (UP) See note 4. (DOWN) (UP/DOWN A) (UP/DOWN B) (UP/DOWN C) When using as a dual counter: Dual count calculating mode Note 4: Displayed for output modes other than K-2, D, L, and H only. Output mode See note 5. See note 5.See note 5.See note 5. See note. (Addition) (Subtraction) Note: Displayed for output modes other than K-2, D, L, and H only. (N) (F) (C) (R) (K-1) (P) (Q) (A) (K-2) (D) (L) (H) See note 6. One-shot output time Note: 5. Display only when the input mode is UP/DOWN A, B, or C with 6-digit models (with H7CX-AU@/-AW@ models only for H). Note 6: When using as a 2-stage counter: Oneshot (0.01s) (0.50s) (99.99s) output 2 time Note: Displayed only when the output mode is C, R, K-1, P, Q, A, or K-2. Oneshot (Outputs held) (0.01s) (99.99s) output If the output time is 0.00, hold is 1 time When using as a batch counter: Function setting mode (0.01s) (0.50s) (99.99s) Note: Displayed only when the output mode is C, R, K-1, P, Q, A, or K-2. Counting speed (30Hz) (5kHz) displayed. Note 1: Displayed for output modes other than D, L, and H. Note 2: HOLD cannot be set when the output mode is K-2. Reset input signal width (20ms) (1ms) Oneshot output 2 time (0.01s) (0.50s) (99.99s) Note: Displayed only when the output mode is C, R, K-1, P, Q, A, or K-2. Decimal point position See note 7. No decimal point Prescale value See note 7. One digit after decimal point Two digits after decimal point Three digits after decimal point (0.001) ∼ (1.000) ∼ (99.999) [9.999] Note 7: The displays for 4-digit models are shown inside parentheses. NPN/PNP input mode (NPN input) Display color (PNP input) (Red) (Green) (Red-green) (Green-red) Note: Displayed for terminal-block models (except H7CX-A11@) only. Output allocation Note: Displayed for H7CX-AU@ models only. Key protect level (KP-1) (KP-2) (KP-3) (KP-4) (KP-5) C-108 Multifunction Preset Counter H7CX (Counter Function) Explanation of Functions Input Mode (cntm) (Setting possible using DIP switch.) Set increment mode (UP), decrement mode (DOWN), or one of the increment/decrement modes (UP/DOWN A, UP/DOWN B, or UP/ DOWN C) as the input mode. Input modes other than UP or DOWN modes cannot be set using the DIP switch and so use the operation keys if other modes are required. (For details on the operation of the input modes, refer to Input Modes and Present Value on page 112.) Prescale Value (pscl) Pulses input to the counter are converted according to the specified prescale value. (Setting range: 0.001 to 99.999 for 6-digit models and 0.001 to 9.999 for 4-digit models.) Example: To display the feed distance for systems that output 25 pulses for a feed length of 0.5 m in the form @@.@@ m: 2. Set the prescale value to 0.02 (0.5÷25). 0.5 m Dual Count Calculating Mode (calm) When using as a dual counter, select either ADD (addition) or SUB (subtraction) as the calculation method for the dual count value. SUB mode can be used only when K-2, D, L, or H is selected as the output mode with 6-digit models. ADD: SUB: Dual count value = CP1 PV + CP2 PV Dual count value = CP1 PV − CP2 PV Output Mode (outm) (Setting possible using DIP switch.) 25 pulses Set the way that control output for the present value is output. The possible settings are N, F, C, R, K-1, P Q, A, K-2, D, L, and H. Output , modes other than N, F, C, or K-1 cannot be set using the DIP switch and so use the operation keys if other modes are required. The output modes that can be set vary with the model. (For details on the operation of the output modes, refer to Input/Output Mode Settings on page 113.) Encoder NPN/PNP Input Mode (imod) Select either NPN input (no-voltage input) or PNP input (voltage input) as the input format. The same setting is used for all external inputs. For details on input connections, refer to Input Connection on page 96. One-shot Output Time (otim) (Setting possible using DIP switch.) Set the one-shot output time (0.01 to 99.99 s) for control output. One-shot output can be used only when C, R, K-1, P Q, A, or K-2 is , selected as the output mode. Output times other than 0.5 s or 0.05 s cannot be set with the DIP switch and so use the operation keys if other settings are required. Display Color (colr) Set the color used for the present value. Output OFF (See note.) red Red (fixed) Green (fixed) Red Green Green Red grn r-g g-r Output ON (See note.) One-shot Output 2 Time (otm2) (Setting possible using DIP switch.) When using as a 2-stage counter or batch counter, set the one-shot output time (0.01 to 99.99 s) for control output (OUT2). One-shot output can be used only when C, R, K-1, P Q, A, or K-2 is selected as , the output mode. Output times other than 0.5 s or 0.05 s cannot be set with the DIP switch and so use the operation keys if other settings are required. Note: When using as a 2-stage counter, this is the status of output 2. Output Allocation (otst) When using H7CX-AU@ models as a 2-stage counter, the output can be flexibly allocated to either stage 1 or 2. Transistor output can be allocated to SV1 and contact output for SV2 or vice verse, as in the following table. One-shot Output 1 Time (otm1) When using as a 2-stage counter, set the one-shot output time (0.01 to 99.99 s) for control output (OUT1). One-shot output can be used only when D, L, or H is selected as the output mode. If the output time is set to 0.00, hold is displayed, and outputs are held. HOLD cannot be set when the output mode is K-2. H7CX-AU/-AUD1 OUT1 off Transistor (12-13) Contact (3, 4, 5) on OUT2 Contact (3, 4, 5) Transistor (12-13) Counting Speed (cnts) (Setting possible using DIP switch.) Set the maximum counting speed (30 Hz/5 kHz) for CP1 and CP2 inputs together. If contacts are used for input signals, set the counting speed to 30 Hz. Processing to eliminate chattering is performed for this setting. H7CX-AUSD1 OUT1 off on Transistor (12-13) Transistor with diode (3, 4, 5) OUT2 Transistor with diode (3, 4, 5) Transistor (12-13) Reset Input Signal Width (iflt) (Setting possible using DIP switch.) Set the reset input signal width (20 ms/1 ms) for reset/reset 1 and total reset/reset 2 inputs together. If contacts are used for input signals, set the counting speed to 20 ms. Processing to eliminate chattering is performed for this setting. Decimal Point Position (dp) Decide the decimal point position for the present value, CP1/CP2 present values, set value (SV1, SV2), total count value, and dual count set value. Multifunction Preset Counter H7CX (Counter Function) C-109 Counters 1. Set the decimal point position to 2 decimal places. Key Protect Level (kypt) Set the key protect level. When the key-protect switch in set to ON, it is possible to prevent setting errors by prohibiting the use of certain operation keys by specifying the key protect level (KP-1 to KP-5). The key protect indicator is lit while the key-protect switch is set to ON. Confirm the ON/OFF status of the keyprotect switch after the H7CX is mounted to the panel. (See note) OFF ON Note: Factory-set to OFF Key protect indicator Level Meaning Changing mode (See note.) Details Switching display in run mode Yes Yes Reset key Up/down key (Up key for 6-digit models) Yes KP-1 (default setting) No KP-2 No Yes No Yes KP-3 No Yes Yes No KP-4 No Yes No No KP-5 No No No No Note: Changing mode to configuration selection mode ( MODE + 1 1 s min.) or function setting mode ( MODE 3 s min.). C-110 Multifunction Preset Counter H7CX (Counter Function) Operation in Run Mode Set values for each digit as required using the and keys. ( key only for 6-digit models.) 1-stage Counter Present value Set value Present Value Shows the present count value. Set Value (Set Value 1, Set Value 2) Set the set value. When the present value reaches the set value, signals are output according to the specified output mode. Counters 2-stage Counter Present value Set value 1 Present value Set value 2 Total and Preset Counter Present value Set value Present Value/Set Value Same as 1-stage counter. Total Count Value Shows the present total count value. Total count value Batch Counter Present Value/Set Value Same as 1-stage counter. Present value Set value Batch Count Value Shows the number of times the count has been completed for the present value. Batch Count Set Value Set the batch count set value. When the batch count value reaches the batch count set value, batch output (OUT1) turns ON. Batch count value Batch count set value Dual Counter Dual Count Value Shows the sum of the CP1 present value and CP2 present value when the dual count calculating mode is ADD and shows the value obtained by subtracting the CP2 present value from the CP1 present value when the dual count calculating mode is SUB. Dual Count Set Value Set the dual count set value. When the dual count value reaches the dual count set value, signals are output according to the specified output mode. CP1/CP2 Present Value Show the present count values for CP1 and CP2 present values respectively. Dual count value Dual count set value CP1 present value CP2 present value Multifunction Preset Counter H7CX (Counter Function) C-111 Input Modes and Present Value UP (Increment) Mode DOWN (Decrement) Mode CP1: Count input; CP2: Prohibit (gate) input H CP1 L A Prohibit A CP1: Count input; CP2: Prohibit (gate) input H CP1 L A A H CP2 L 5 H CP2 L n n−1 n−2 Prohibit Present value 2 1 0 0 4 3 Present value n−3 n−4 n−5 0 a must be greater than the minimum signal width. (See note 2.) CP1: Prohibit (gate) input; CP2: Count input H CP1 L H CP2 L 5 A A a must be greater than the minimum signal width. (See note 2.) CP1: Prohibit (gate) input; CP2: Present value H CP1 L A A Prohibit CP2 H L n n−1 Prohibit Present value 2 1 4 3 n−2 Present value n−3 n−4 n−5 0 a must be greater than the minimum signal width. (See note 2.) UP/DOWN A Command Input Mode H CP1 L A A 0 0 a must be greater than the minimum signal width. (See note 2.) Note: 1. If the configuration selection is set to dual counter, CP1 and CP2 input will operate in the same way as the count input (CP1) of UP (increment) mode. 2. a must be greater than the minimum signal width and b must be at least 1/2 the minimum signal width. If they are less, a count error of ±1 may occur. Minimum signal width: 16.7 ms (when maximum counting speed = 30 Hz) 100 µs (when maximum counting speed = 5 kHz) 3. The meaning of the H and L symbols in the tables is explained below. Input method Symbol H L No-voltage input (NPN input) Short-circuit Open Voltage input (PNP input) 4.5 to 30 VDC 0 to 2 VDC H CP2 L 3 2 1 0 0 2 1 2 3 Prese nt val ue a must be greater than the minimum signal width. (See note 2.) UP/DOWN B Individual Input Mode H CP1 L H CP2 L 3 2 1 0 0 2 1 1 2 3 Present value UP/DOWN C Quadrature Input Mode H CP1 L H L 3 3 2 1 2 BBBB CP2 Present value 1 0 2 0 b must be at least 1/2 the minimum signal width. (See note 2.) C-112 Multifunction Preset Counter H7CX (Counter Function) Input/Output Mode Settings Operation for 1-stage models is the same as that for OUT2. When using a 2-stage model as a 1-stage counter, total and preset counter, or dual counter, OUT1 and OUT2 turn ON and OFF simultaneously. Input mode UP Output mode setting N Reset/ reset 1 999999 Set value 2 Set value 1 One-shot output from OUT1 (The one-shot output time can be set in the range 0.01 to 99.99s.) Self-holding output Self-holding output One-shot output from OUT2 DOWN UP/DOWN A, B, C Operation after count completion Counters The outputs and present value display are held until reset/reset 1 is input. 0 OUT1 OUT2 F Reset/ reset 1 999999 Set value 2 Set value 1 The present value display continues to increase/decrease. The outputs are held until reset/reset 1 is input. 0 OUT1 OUT2 C Reset/ reset 1 999999 Set value 2 Set value 1 0 OUT1 OUT2 As soon as the count reaches SV, the present value display returns to the reset start status. The present value display does not show the present value upon count-up. The outputs repeat one-shot operation. OUT1 self-holding output turns OFF after the OUT2 one-shot output time.The OUT1 oneshot output time is independent of OUT2. The present value display returns to the reset start status after the one-shot output time. The outputs repeat one-shot operation. OUT1 self-holding output turns OFF after the OUT2 one-shot output time.The OUT1 oneshot output time is independent of OUT2. R Reset/ reset 1 999999 Set value 2 Set value 1 0 OUT1 OUT2 Note: 1. 2. 3. 4. 5. The full scale (FS) for H7CX 4-digit models is 9999. When the present value reaches 999999, it returns to 0. Counting cannot be performed during reset/reset 1 input. If reset/reset 1 is input while one-shot output is ON, one-shot output turns OFF. If there is power failure while output is ON, output will turn ON again when the power supply has recovered. For one-shot output, output will turn ON again for the duration of the output time setting once the power supply has recovered. 6. Do not use the counter function in applications where the count may be completed (again) while one-shot output is ON. Multifunction Preset Counter H7CX (Counter Function) C-113 Input mode UP Output mode setting K-1 Reset/ reset 1 999999 Set value 2 Set value 1 DOWN UP/DOWN A, B, C Operation after count completion The present value display continues to increase/decrease. OUT1 self-holding output turns OFF after the OUT2 one-shot output time.The OUT1 one-shot output time is independent of OUT2. The present value display does not change during the one-shot output time period, but the actual count returns to the reset start status. The outputs return to the one-shot start state and repeat oneshot operation. OUT1 self-holding output turns OFF after the OUT2 one-shot output time. The OUT1 one-shot output time is independent of OUT2. The present value continues to increase/ decrease for the oneshot output time, but returns to the reset start status after the one-shot output time has elapsed. The outputs repeat one-shot operation. OUT1 self-holding output turns OFF after the OUT2 one-shot output time. The OUT1 one-shot output time is independent of OUT2. The present value display and OUT1 selfholding output is held until reset/reset 1 is input. OUT1 and OUT2 are independent. 0 OUT1 OUT2 P Reset/ reset 1 999999 Set value 2 Set value 1 0 OUT1 OUT2 Q Reset/ reset 1 999999 Set value 2 Set value 1 0 OUT1 OUT2 A Reset/ reset 1 999999 Set value 2 Set value 1 0 OUT1 OUT2 Note: 1. 2. 3. 4. 5. The full scale (FS) for H7CX 4-digit models is 9999. When the present value reaches 999999, it returns to 0. Counting cannot be performed during reset/reset 1 input. If reset/reset 1 is input while one-shot output is ON, one-shot output turns OFF. If there is power failure while output is ON, output will turn ON again when the power supply has recovered. For one-shot output, output will turn ON again for the duration of the output time setting once the power supply has recovered. 6. Do not use the counter function in applications where the count may be completed (again) while one-shot output is ON. C-114 Multifunction Preset Counter H7CX (Counter Function) (The one-shot output time can be set in the range 0.01 to 99.99s.) Self-holding Instantaneous One-shot output (equals) output output Input mode UP/DOWN A, B, C Output mode setting K-2 Reset/ reset 1 Operation after count completion The display continues to increase/decrease until the overflow or underflow value is reached. One-shot output only. 999999 Set value 2 Set value 1 0 −99999 OUT1 OUT2 D Reset/ reset 1 999999 Set value 2 Set value 1 0 −99999 The display continues to increase/decrease until the overflow or underflow value is reached. The outputs are ON while the count is equal. OUT1 OUT2 L Reset/ reset 1 999999 Set value 2 Set value 1 0 −99999 The display continues to increase/decrease until the overflow or underflow value is reached. OUT1 is held while the present value is less than or equal to set value 1. OUT2 is held while the present value is greater than or equal to set value 2. OUT1 OUT2 H Reset/ reset 1 999999 Set value 2 Set value 1 0 −99999 OUT1 OUT2 The display continues to increase/decrease until the overflow or underflow value is reached. OUT1 is held while the present value is greater than or equal to set value 1. OUT2 is held while the present value is greater than or equal to set value 2. Note: H mode is available only when using a 6-digit model as a 2stage counter. Note: 1. Counting cannot be performed during reset/reset 1 input. 2. If reset/reset 1 is input while one-shot output is ON, one-shot output turns OFF. 3. If there is power failure while output is ON, output will turn ON again when the power supply has recovered. For one-shot output, output will turn ON again for the duration of the output time setting once the power supply has recovered. 4. Do not use the counter function in applications where the count may be completed (again) while one-shot output is ON. Multifunction Preset Counter H7CX (Counter Function) C-115 Counters Total and Preset Counter Operation The H7CX has a total counter, separate from the 1-stage preset counter, for counting the total accumulated value. Reset/reset 1 Total reset/reset 2 Present value 0 999999 Total count value 0 Note: The full scale (FS) for H7CX 4-digit models is 9999. • The total counter continues to count the total accumulated value when the present value is reset using reset/reset 1 input (reset key). • The total count value is reset when the total reset/reset 2 input is turned ON. If the reset key is pressed while the total count value is displayed, the total count value is reset. The present value is also reset at this time. • The counting range of the total counter is −99,999 to 999,999 (−999 to 9,999). The total count value returns to 0 when it reaches the full scale limit. Batch Counter Operation The H7CX has a batch counter, separate from the 1-stage preset counter, for counting the number of times the count has been completed. Reset 1 Reset 2 (batch counter reset) Set value Present value 0 OUT2 Batch count set value Batch count value 0 • The batch counter continues after count completion. • Batch output is held until batch counter reset is input. • When the batch counter reset input is turned ON, the batch count value is reset, and batch output turns OFF. • If the reset key is pressed while the batch count value is displayed, the batch count value is reset and batch output turns OFF. The present value is also reset at this time. OUT1 (batch output) Note: The above is for when the output mode is C. Note: 1. 2. 3. 4. 5. 6. The batch count value is held at 0 during batch counter reset input. If the batch count set value is 0, batch count will be performed but there will be no batch output. The batch count value returns to 0 when it reaches 999,999 (9,999 for 4-digit models). Once batch input has been turned ON, it will return to the ON state after power interruptions. If the batch count set value is changed from a value that is greater than the batch count value to one that is less, batch output will turn ON. After batch output turns ON, the ON state will be held even if the batch count set value is changed to a value greater than the batch count value. C-116 Multifunction Preset Counter H7CX (Counter Function) Dual Counter Operation Using the dual counter allows the count from 2 inputs to be added or subtracted and the result displayed. It is possible to specify a set value for which output turns ON when the set value matches the added or subtracted result. OUT1 and OUT2 turn ON and OFF simultaneously. Dual Count Calculating Mode = ADD Dual count value = CP1 PV + CP2 PV Reset 1 (CP1 reset) Reset 2 (CP2 reset) Dual count set value Dual count value 0 Dual Count Calculating Mode = SUB Dual count value = CP1 PV − CP2 PV Reset 1 (CP1 reset) Reset 2 (CP2 reset) Dual count value Dual count set value 0 CP1 present value CP1 present value 0 0 CP2 present value 0 CP2 present value 0 • The operation after count completion for the dual counter value is determined by the output mode. • The CP1 present value is reset when reset 1 input is turned ON and the CP2 present value is reset when reset 2 input is turned ON. • If the reset key is pressed while the dual count value, CP1 present value, or CP2 present value is displayed, all of the present values are reset and outputs turn OFF. At this time, counting is not possible for CP1 or CP2 inputs. OUT1, 2 OUT1, 2 Note: The above is for when the output mode is N. Note: The above is for when the output mode is K-2. SUB mode can be used only when K-2, D, L, or H is selected as the output mode with 6-digit models. Note: 1. Counting is not possible for CP1 during reset 1 input. CP2 will not be affected. The dual count value will be calculated based on a CP1 present value of 0. 2. Counting is not possible for CP2 during reset 2 input. CP1 will not be affected. The dual count value will be calculated based on a CP2 present value of 0. 3. The counting range for the dual count value is −99,999 to 999,999 (−999 to 9,999 for 4-digit models). The counting ranges for the CP1 present value and CP2 present value are 0 to 999,999 (0 to 9,999 for 4-digit models). If a present value exceeds 999,999 (9,999 for 4digit models), FFFFFF (FFFF for 4-digit models) will be displayed to indicate an overflow, and all counting will stop. Reset Function List Function Screen displayed in run mode Reset/reset 1 Total reset/reset 2 Reset key 1-stage/2-stage counter Present value/ set value (1, 2) Total and preset counter Present value/ set value Total count value Batch counter Present value/ set value Dual counter CP1 present value/CP2 present value Batch count Dual count value/batch value/dual count set value count set value Present value Present value and output reset. and output reset. No effect. Present value and output reset. Only the CP1 present value is reset. Only the total count value is reset. Batch count value and batch output Only the CP2 present value is rereset. set. CP1 present value, CP2 present Present value Present value Present value, Present value Present value, and output reset. and output reset. total count value, and output reset. batch count val- value, dual count value, and output reset. and output reset. ue, output and batch output reset. Multifunction Preset Counter H7CX (Counter Function) C-117 Counters I Operating Procedures (Tachometer Function) Switching from Counter to Tachometer The H7CX is factory-set to the 2-stage counter (1-stage counter for H7CX-AU@ models) configuration. To switch to the tachometer configuration, use the procedure shown on the right. For details, refer to page 39. Power ON Configuration selection mode Run mode MODE + Hold down for 1 1 s min. (See note.) Switch to 2cnt to taco (tachometer operation) using the key. Note: The MODE key must be pressed before the 1 key. Settings for Basic Operations Settings for basic functions can be performed with just the DIP switch. Be sure to set pin 1 to ON. 1 2 3 4 5 6 7 8 ON OFF Note: All of the pins are factory-set to OFF. Item 1 DIP switch settings enable/ disable OFF Disabled ON Enabled Pin 3 OFF ON 10 kHz OFF ON Pin 4 OFF OFF ON ON Tachometer output mode Upper and lower limit Area Upper limit Lower limit 2 3 4 5 6 7 8 Counting speed 30 Hz Tachometer out- Refer to the table on the right. put mode Average processing --Refer to the table on the right. ----PNP Pin 5 OFF ON OFF ON Pin 6 OFF OFF ON ON Average processing OFF (no average processing) 2 times 4 times 8 times NPN/PNP input NPN mode Easy Confirmation of Switch Settings Using Indicators The ON/OFF status of the DIP switch pins can be confirmed using the front display. For details, refer to page 124. Note: 1. Be sure to set pin 1 of the DIP switch to ON. If it is set to OFF, the DIP switch settings will not be enabled. 2. Changes to DIP switch settings are enabled when the power is turned ON. Advanced-Function Settings After making DIP switch settings for basic operations, advanced-functions (see note) can be added using the operation keys. For details, refer to page 34. Note: Advanced functions consist of decimal point position, prescale value, auto-zero time, startup time, display color, output allocation, and key protect level. C-118 Multifunction Preset Counter H7CX (Tachometer Function) Settings for Advanced Functions Note: When using as a tachometer, switch to the tachometer configuration using the procedure given on page 124. Settings that cannot be performed with the DIP switch are performed with the operation keys. Power ON Note: 1. If the mode is switched to the function setting mode during operation, operation will continue.tion, operation will continue. 2. Changes made to settings in function setting mode are enabled for the first time when the mode is changed to run mode. Also, whensettings are changed, the counter is reset (measured values initial-ized and output turned OFF) on returning to run mode. For details on operations in run mode, refer to page 37. Run mode (See note 1.) 3s min. (See note 2.) The characters displayed in reverse video are the initial values. 3s min. When performing settings with operation keys only, set pin1 of the DIP switch to OFF (factory setting). If pin 1 of the DIP switch is set to ON, the setting items indicated by will not be displayed. Set each setting item using the Tachometer output mode (HI-LO) (AREA) (HI-HI) keys. (LO-LO) Counting speed (30Hz) (10kHz) Decimal point position (No decimal point) (One digit after decimal point) (Two digits after decimal point) (Three digits after decimal point) Prescale value Function setting mode (0.001) ∼ (1.000) ∼ (99.999) Average processing (No average processing) (Average of 2 measurements) (Average of 4 measurements) (Average of 8 measurements) Auto-zero time (0.1s) ∼ ∼ (99.9s) Startup time (0.0s) (99.9s) NPN/PNP input mode (NPN input) Display color (Red) (PNP input) (Green) (Red-green) (Green-red) Output allocation Note: Displayed for H7CX-AU@ models Key protect level (KP-1) (KP-2) (KP-3) (KP-4) (KP-5) Multifunction Preset Counter H7CX (Tachometer Function) C-119 Counters Explanation of Functions Tachometer Output Mode (totm) (Setting possible using DIP switch.) Set the output method for control output based on the OUT1/OUT2 set value. Upper and lower limit (HI-LO), area (AREA), upper limit (HI-HI), and lower limit (LO-LO) can be set. (For details on the operation of the output modes, refer to Output Mode Settings on page 123.) Auto-zero Time (aut=) It is possible to set the H7CX so that if there is no pulse for a certain time the display is force-set to 0. This time is called the auto-zero time. Set the auto-zero time to a time slightly longer than the estimated interval between input pulses and within the setting range (0.1 to 99.9 s). It will not be possible to make accurate measurements if the auto-zero time is set to a time shorter than the input pulse cycle. Setting a time that is too long may also result in problems, such as a time-lag between rotation stopping and the alarm turning ON. Counting Speed (cnts) (Setting possible using DIP switch.) Set the maximum counting speed (30 Hz/10 kHz) for CP1 input. If contacts are used for input signals, set the counting speed to 30 Hz. Processing to eliminate chattering is performed for this setting. Startup Time (stmr) In order to prevent undesired output resulting from unstable input immediately after the power supply is turned ON, it is possible to prohibit measurement for a set time (0.0 to 99.9 s), the startup time. It can also be used to stop measurement and disable output until the rotating body reaches the normal rate of rotation, after the power supply to the H7CX and rotating body are turned ON at the same time. Display Startup time Decimal Point Position (dp) Decide the decimal point position for the measurement value, OUT1 set value, and OUT2 set value. Prescale Value (pscl) It is possible to display the rate of rotation or the speed of a device or machine to which the H7CX is mounted by converting input pulses to a desired unit. If this prescaling function is not used, the input frequency (Hz) will be displayed. The relationship between display and input is determined by the following equation. Set the prescale value according to the unit to be displayed. Displayed value = f × a f: Input pulse frequency (number of pulses in 1 second) a: Prescale value 1. Displaying Rotation Rate Display unit rpm rps N: Number of pulses per revolution Example:In order to display the rate of rotation for a machine that outputs 5 pulses per revolution in the form @@.@ rpm: 1. Set the decimal point position to 1 decimal place. 2. Using the formula, set the prescale value to 1/N × 60 = 60/5 = 12. 2. Displaying Speed Display unit m/min m/s Prescale value (a) πd × 1/N × 60 πd × 1/N 1/N Prescale value (a) 1/N × 60 Comparison value (lower limit) Time Power supply Output (lower limit) NPN/PNP Input Mode (imod) Select either NPN input (no-voltage input) or PNP input (voltage input) as the input format. The same setting is used for all external inputs. For details on input connections, refer to The circuit shown above is for no-voltage input (NPN input). on page 96. Display Color (colr) Set the color used for the measurement value. Setting Control output OFF Red (fixed) Green (fixed) Measured value displayed in green when either control output 1 or control output 2 is ON. Control output ON red grn r-g Measured value displayed (See note in red when both control outputs 1 and 2 are OFF. 1.) N: Number of pulses per revolution d: Diameter of rotating body (m) πd: Circumference (m) Measured value displayed Measured value displayed (See note in green when both control in red when either control outputs 1 and 2 are OFF. output 1 or control output 2 2.) is ON. g-r d:Diameter of rotating body Note: 1. If the tachometer output mode is set to AREA, however, the measured value is displayed in red when control output 1 is OFF and in green when control output 1 is ON. 2. If the tachometer output mode is set to AREA, however, the measured value is displayed in green when control output 1 is OFF and in red when control output 1 is ON. Average Processing (aug) (Setting possible using DIP switch.) Flickering display and output chattering can be prevented using average processing (simple averaging). Average processing can be set to one of four levels: no average processing, 2 times (i.e., the average of 2 measurement values), 4 times, or 8 times. The measurement cycle will be equal to the sampling cycle (200 ms) multiplied by the average processing setting (i.e., the number of times). Average processing enables fluctuating input signals to be displayed stably. Set the optimum number of times for the application. C-120 Multifunction Preset Counter H7CX (Tachometer Function) Output Allocation (otst) When using H7CX-AU@ models as 2-stage counter, each output can be flexibly allocated to either stage 1 or 2. Transistor output placed for SV1 and contact output for SV2 or vice verse, as in the following table. H7CX-AU/-AUD1 OUT1 OUT2 Counters Details Changing mode (See note.) KP-1 (default setting) No Switching display during operation Yes Yes Reset key Up/down key (Up key for 6-digit models) Yes Yes No Yes Yes Yes No Yes No No No No No 1 off on Transistor (12-13) Contact (3, 4, 5) Contact (3, 4, 5) Transistor (12-13) H7CX-AUSD1 OUT1 OUT2 Transistor with diode (3, 4, 5) Transistor (12-13) off on Transistor (12-13) Transistor with diode (3, 4, 5) Key Protect Level (kypt) Set the key protect level. When the key-protect switch in set to ON, it is possible to prevent setting errors by prohibiting the use of certain operation keys by specifying the key protect level (KP-1 to KP-5). The key protect indicator is lit while the key-protect switch is set to ON. Confirm the ON/OFF status of the keyprotect switch after the H7CX is mounted to the panel. (See note) OFF ON Note: Factory-set to OFF Key protect indicator Level Meaning KP-2 No KP-3 No KP-4 No KP-5 No Note: Changing mode to configuration selection mode ( MODE + 1 s min.) or function setting mode ( MODE 3 s min.). Multifunction Preset Counter H7CX (Tachometer Function) C-121 Operation in Run Mode Set values for each digit as required using the key. Measurement value Measurement Value Displays the currently measured value. OUT1/OUT2 Set Value Set OUT1 set value and OUT2 set value. The measurement value is compared to OUT1 set value and OUT2 set value and output is made according to the selected output mode. Measurement value OUT1 set value Measurement value OUT2 set value C-122 Multifunction Preset Counter H7CX (Tachometer Function) Output Mode Settings Output mode setting Upper and lower limit (HI-LO) (Upper-limit) OUT2 set value Measurement value (Lower-limit) OUT1 set value OUT1 OUT2 ON condition for OUT1: measurement value ≤ OUT1 set value ON condition for OUT2: measurement value ≥ OUT2 set value Area (AREA) OUT2 set value Measurement value OUT1 set value OUT1 OUT2 Condition OUT1 set value ≤ OUT2 set value OUT1 set value > OUT2 set value OUT2 set value ≤ measurement value ≤ OUT1 set value measurement value < OUT2 set value or measurement value > OUT1 set value OUT1 set value ≤ measurement value ≤ OUT2 set ON condition value for OUT1 measurement value < OUT1 set value ON condition or for OUT2 measurement value > OUT2 set value Upper limit (HI-HI) (Upper-limit) OUT2 set value Measurement value (Upper-limit) OUT1 set value OUT1 OUT2 ON condition for OUT1: Measurement value ≥ OUT1 set value ON condition for OUT2: Measurement value ≥ OUT2 set value Lower limit (LO-LO) (Lower-limit) OUT2 set value Measurement value (Lower-limit) OUT1 set value OUT1 OUT2 ON condition for OUT1: Measurement value ≤ OUT1 set value ON condition for OUT2: Measurement value ≤ OUT2 set value Multifunction Preset Counter H7CX (Tachometer Function) C-123 Counters I Operation in Configuration Selection Mode Select which H7CX configuration is used (i.e., 1-stage counter, 2-stage counter, total and preset counter, batch counter, dual counter, or tachometer) in configuration selection mode. The H7CX is also equipped with a DIP switch monitor function, a convenient function that enables the settings of the DIP switch pins to be confirmed using the front display. Counting stopped Counting possible Power ON 1 Run Mode 1 To change the mode to configuration selection mode, press the 1 Key for 1 s min. with the key held down. The mode will not change if the 1 key is pressed first. (See note 2.) + 1 (See note 1.) 1 s min. Select the configuration using the keys. ( key only for 6digit models) The H7CX is factory-set to the 1-stage counter configuration (2-stage counter configuration with H7CX-AW@/-A4W@ models). Configuration Selection Mode Configuration selection (1-stage counter) (2-stage counter) (Total and preset counter) (Batch counter) (Dual counter) (Tachometer) The configuration that can be selected depend on the model. DIP switch monitor The status of the DIP switch pins (1 to 8) can be confirmed using the keys. Note: This display is possible only if DIP switch pin 1 (DIP switch settings) is set to ON (i.e., enabled). Example 1 2 3 4 5 6 7 8 ON OFF Indicates that DIP switch pin 8 is ON. Indicates that DIP switch pin 7 is OFF. Indicates that DIP switch pin 6 is ON. Indicates that DIP switch pin 5 is OFF. Indicates that DIP switch pin 4 is ON. Indicates that DIP switch pin 3 is OFF. Indicates that DIP switch pin 2 is ON. Indicates that DIP switch pin 1 is ON. Note: 1. When the mode is changed to configuration selection mode, the present value is reset, outputs turns OFF, and counting (measuring) stops. 2. Setting changes made in configuration selection mode are enabled when the mode is changed to run mode. If the configuration is changed, the set value (or set value 1 and set value 2), OUT1 set value or OUT2 set value are initialized. C-124 Multifunction Preset Counter H7CX Additional Information I Using the Operation Keys Counter Operation Power ON + 1 Counting stopped Counting possible 1 s min. Configuration selection mode + Configuration selection Present value, set value DIP switch monitor 3 s min. Run mode Function setting mode 3 s min. Input mode 1 1 s min. 1-stage counter Dual count calculating mode 2-stage counter Output mode Present value, set value 1 One-shot output time Present value, set value 2 One-shot output 2 time Total and preset counter Present value, set value One-shot output 1 time Counting speed Total count value Reset input signal width Decimal point position Batch counter Prescale value Present value, set value NPN/PNP input mode Batch count value, batch count set value Display color Output allocation Dual counter Key protect level Dual count value, dual count set value CP1 present value, CP2 present value and keys ( key only with 6-digit models). Note: 1. Perform settings using the 2. The above flowcharts outline the procedures for all models. For more details on each model, refer to page 107. Multifunction Preset Counter H7CX C-125 Counters Tachometer Operation Power ON + 1 Counting stopped Counting possible 1 s min. Configuration selection mode + Configuration selection 3 s min. Run mode Function setting mode 3 s min. Measurement value Measurement value, OUT1 set value 1 Tachometer output mode 1 s min. DIP switch monitor Counting speed Measurement value, OUT2 set value Decimal point position Prescale value Average processing Auto-zero time Startup time NPN/PNP input mode Display color Output allocation Key protect level Note: 1. All setting changes are performed using the 2. For details, refer to page 118. key. C-126 Multifunction Preset Counter H7CX I Lists of Settings Fill in your set values in the set value column of the following tables and utilize the tables for quick reference. Configuration Selection Mode Parameter name Configuration selection DIP switch monitor Parameter func dip Setting range 1cnt/2cnt/tcnt/bcnt/dcnt/taco (See note 1.) on/off Default value 1cnt (See note 2.) off ------Counters Set value --Set value --Set value --Set value --Unit Set value Note: 1. The setting range varies with the model. 2. The default value for H7CX-AW@/-A4W@ models is 2cnt. Settings for Counter Operation Run Mode • 1-stage Counter Parameter name Present value, set value Present value Set value Parameter ----Setting range -99999 to 999999 (-999 to 9999) 0 to 999999 (0 to 9999) (For conditions other than those described in note 1.) -99999 to 999999 (-999 to 9999) (See note 1.) • 2-stage Counter Parameter name Present value, set value 1 Present value Set value 1 Parameter ----Setting range -99999 to 999999 (-999 to 9999) 0 to 999999 (0 to 9999) (For conditions other than those described in note 1.) -99999 to 999999 (-999 to 9999) (See note 1.) Present value, set value 2 Present value Set value 2 -----99999 to 999999 (-999 to 9999) 0 to 999999 (0 to 9999) (For conditions other than those described in note 1.) -99999 to 999999 (-999 to 9999) (See note 1.) • Total and Preset Counter Parameter name Present value, set value Present value Set value Parameter ----Setting range -99999 to 999999 (-999 to 9999) 0 to 999999 (0 to 9999) (For conditions other than those described in note 1.) -99999 to 999999 (-999 to 9999) (See note 1.) Total count value • Batch Counter Parameter name Present value, set value Present value Set value Parameter ----Setting range -99999 to 999999 (-999 to 9999) 0 to 999999 (0 to 9999) (For conditions other than those described in note 1.) -99999 to 999999 (-999 to 9999) (See note 1.) Batch count Batch count value, batch value count set value Batch count set value ----0 to 999999 (0 to 9999) 0 to 999999 (0 to 9999) 0 0 ------Default value 0 0 ----Unit ---99999 to 999999 (-999 to 9999) 0 ----Default value 0 0 ----Unit Default value 0 0 0 0 0 0 ----------Unit Default value 0 0 ---Unit Multifunction Preset Counter H7CX C-127 • Dual Counter Parameter name Parameter Setting range -99999 to 999999 (-999 to 9999) Default value 0 ----Unit --Set value Dual count Dual count value --value, dual count Dual count set --set value value 0 to 999999 (0 to 9999) (For conditions other 0 than those described in note 2.) -99999 to 999999 (-999 to 9999) (See note 2.) CP1 present value, CP2 present value CP1 present value CP2 present value ----- 0 to 999999 (0 to 9999) 0 to 999999 (0 to 9999) 0 0 ----- ----- Note: 1. The input mode is increment/decrement mode and the output mode is K-2, D, L, or H. 2. The dual count calculating mode is subtraction mode and the output mode is K-2, D, L, or H. Function Setting Mode Parameter name Input mode Dual count calculating mode Output mode One-shot output time One-shot output 2 time One-shot output 1 time Counting speed Reset input signal width Decimal point position Prescale value NPN/PNP input mode Display color Output allocation Key protect level Parameter cntm caln outm otim otm2 otm1 cnts iflt dp pscl imod colr otst kypt Setting range up/down/ud-a/ud-b/ud-c (See note 1.) add/sub (See note 1.) n/f/c/r/k-1/p/q/a/k-2/d/l/h (See note 2.) 0.01 to 99.99 0.01 to 99.99 hold/0.01 to 99.99 (See note 3.) 30h=/skh= 20ms/1ms ------/-----.-/----.--/---.--(----/---.-/--.--/-.---) 0.001 to 99.999 (0.001 to 9.999) npn/pnp red/grn/r-g/g-r off/on kp-1/kp-2/kp-3/kp-4/kp-5 Default value up add n 0.50 0.50 hold 30h= 20ms -----(----) 1.000 npn red off kp-1 ----------------s s s ----Unit Set value Note: 1. The setting range varies with the output mode. 2. The setting range varies with the model and the input mode. 3. HOLD cannot be set when the output mode is K-2. C-128 Multifunction Preset Counter H7CX Settings for Tachometer Operation Run Mode Parameter name Measurement value Measurement value, OUT1 set value Measurement value, OUT2 set value Measurement value OUT1 set value Measurement value OUT2 set value ----------Parameter Setting range 0 to 999999 0 to 999999 0 to 999999 0 to 999999 0 to 999999 0 0 0 0 0 Default value ------------Unit ----Counters Set value Set value Function Setting Mode Parameter name Tachometer output mode Counting speed Prescale value Average processing Auto-zero time Startup time Display color Output allocation Key protect level Parameter totm cnts pscl aUg aut= stmr colr otst kypt hold/area/hihi/lolo 30h=/10kh= ------/-----.-/----.--/---.--0.001 to 99.999 off/2/4/8 0.1 to 99.9 0.0 to 99.9 npn/pnp red/grn/r-g/g-r off/on kp-1/kp-2/kp-3/kp-4/kp-5 Setting range Default value hilo 30h= -----1.000 off 99.9 0.0 npn red off kp-1 ------------s s ------Unit Decimal point position dp NPN/PNP input mode imod Multifunction Preset Counter H7CX C-129
H7CX-A4D 价格&库存

很抱歉,暂时无法提供与“H7CX-A4D”相匹配的价格&库存,您可以联系我们找货

免费人工找货