0
登录后你可以
  • 下载海量资料
  • 学习在线课程
  • 观看技术视频
  • 写文章/发帖/加入社区
会员中心
创作中心
发布
  • 发文章

  • 发资料

  • 发帖

  • 提问

  • 发视频

创作活动
H7ECNV

H7ECNV

  • 厂商:

    OMRON(欧姆龙)

  • 封装:

  • 描述:

    Self-Powered Totalizer

  • 数据手册
  • 价格&库存
H7ECNV 数据手册
Self-powered Totalizer Compact Economical Totalizer with High Visibility Available with Backlit LCD Display • Large display with 8.6-mm character height. • Includes new models with backlight for improved visibility in dimly lit places. (Requires 24-VDC power supply.) • Black and light-gray cases now available. • PNP/NPN universal DC voltage input types now available. • Battery is replaceable for Totalizer reuse and conservation of the environment. • Key-protect switch to prevent faulty reset key operation. • Dual operation mode. • Front face compatible with NEMA4/IP66. • Short body, all models have a depth of 48.5 mm. • Finger protection terminal block conforms to VDE0106 Part100. • Conforms to UL, CSA, and CE marking. Conforms to EN61010-1 (pollution degree 2/overvoltage category III.) • Conforms to EMC standards and EN61326, thus allowing use in residential, commercial and light- and heavy-industry environments. • Six-language instruction manual provided. • PCB-mounting models available. (Requires 3-V power supply.) ■ Broad Line-up of the H7E Series RC H7E H7EC Total Counter • 8-digit H7ET Time Counter • 999999.9h/ 3999d23.9h • 999h59min59s/ 9999h59.9min H7ER Tachometer H7E@-N@P PCB-mounting Counter • 1,000 s-1 with 1 pulse/rev. encoder • 1,000.0 s-1 with 10 pulse/rev. encoder • Total Counter (8-digit) • Time Counter (999999.9h) • 1,000 min-1 with 60 pulse/rev. encoder • 10,000 min-1 with 60 pulse/rev. encoder • 1,000.0 min-1 with 600 pulse/rev. encoder Contents Self-powered Totalizers H7EC..................................................................................................................... H7ET ..................................................................................................................... H7ER..................................................................................................................... H7E@-N@P ........................................................................................................... C-9 C-17 C-25 C-31 Common to All Totalizers Accessories ........................................................................................................... C-35 Precautions ........................................................................................................... C-37 Self-powered Totalizer H7E C-7 Counters H7E C-8 Self-powered Totalizer H7E Self-powered Total Counter H7EC Counters • Eight-digits, counting range 0 to 99999999. • Dual input speed: 30 Hz ←→ 1 kHz (except for AC/DC multivoltage input models) Model Number Structure ■ Model Number Legend H7EC - N 1 2 3 1. Count Input None: No-voltage input V: PNP/NPN universal DC voltage input FV: AC/DC multi-voltage input 2. Case Color None: Light gray B: Black 3. Display None: 7-segment LCD without backlight H: 7-segment LCD with backlight Ordering Information ■ Total Counters Count input Max. counting speed Display Model Light-gray body PNP/NPN universal DC voltage input 30 Hz ←→ 1 kHz (switchable) AC/DC multi-voltage input 20 Hz No-voltage 30 Hz ←→ 1 kHz (switchable) Black body 7-segment LCD with backlight H7EC-NV-H H7EC-NV-BH 7-segment LCD H7EC-NV H7EC-NV-B 7-segment LCD H7EC-NFV H7EC-NFV-B 7-segment LCD H7EC-N H7EC-N-B ■ Accessories (Order Separately) Lithium Battery Y92S-36 Wire-wrap Terminal (set of two Terminals) Y92S-37 Compact Flush Mounting Bracket (See note.) Y92F-35 Flush Mounting Adapter 26 mm × 45.3 mm Y92F-75 27.5 mm × 52.5 mm Y92F-76 24.8 mm × 48.8 mm Y92F-77B Note: The New H7E models are supplied with a Y92F-34 Mounting Bracket. Self-powered Total Counter H7EC C-9 Specifications ■ General Item H7EC-NV-@ H7EC-NV-@H Operating mode Up type Mounting method Flush mounting H7EC-NFV-@ H7EC-N-@ External connections Screw terminals, optional Wire-wrap Terminals (see note 1) Reset External/Manual reset Number of digits 8 Count input PNP/NPN universal DC voltage in- AC/DC multi-voltage input put Display 7-segment LCD with or without backlight, zero suppression (character height: 8.6 mm) (see note 2) Max. counting speed 30 Hz/1 kHz Case color Light gray or black (-B models) Attachment Waterproof packing, flush mounting bracket Approved standard UL863, CSA C22.2 No.14, Lloyds Conforms to EN61010-1/IEC61010-1 (Pollution degree2/overvoltage category III) Conforms to VDE0106/P100 No-voltage input 20 Hz 30 Hz/1 kHz Note: 1. Separately ordered Wire-wrap Terminals (Y92S-37) are required. 2. Only PNP/NPN universal DC voltage input models (-H models) have a backlight. ■ Ratings Item H7EC-NV-@ H7EC-NV-@H H7EC-NFV-@ Supply voltage Backlight model: 24 VDC (0.3 W max.) (only for backlight) No-backlight model: Not required (powered by built-in battery) Not required (powered by built-in battery) Count input High (logic) level: 4.5 to 30 VDC Low (logic) level: 0 to 2 VDC (Input impedance: Approx. 4.7 kΩ) High (logic) level: 24 to 240 VAC/VDC, 50/60 Hz Low (logic) level: 0 to 2.4 VAC/VDC, 50/ 60 Hz Reset input No voltage input Maximum short-circuit impedance: 10 kΩ max. Short-circuit residual voltage: 0.5 V max. Minimum open impedance: 750 kΩ min. Max. counting speed (see note) 30 Hz or 1 KHz (Switchable with switch) 20 Hz Minimum signal width 20 Hz: 25 ms 30 Hz: 16.7 ms 1 KHz: 0.5 ms Reset system External reset and manual reset: Minimum signal width of 20 ms Terminal screw tightening torque 0.98 N·m max. Ambient tempera- Operating: -10°C to 55°C (with no condensation or icing) ture Storage: -25°C to 65°C (with no condensation or icing) Ambient humidity Operating 25% to 85% Note: ON/OFF ratio 1:1 C-10 Self-powered Total Counter H7EC H7EC-N-@ No voltage input Maximum short-circuit impedance: 10 kΩ max. Short-circuit residual voltage: 0.5 V max. Minimum open impedance: 750 kΩ min. 30 Hz or 1 KHz (Switchable with switch) ■ Characteristics H7EC-NV-@ H7EC-NV-@H H7EC-NFV-@ H7EC-N-@ Insulation resistance 100 MΩ min. (at 500 VDC) between current-carrying metal parts and exposed non-current-carrying metal parts, and between the backlight power supply terminal and count input terminals/reset terminals for backlight models 100 MΩ min. (at 500 VDC) between 100 MΩ min. (at 500 VDC) between current-carrying metal parts and excurrent-carrying metal parts and exposed non-current-carrying metal parts posed non-current-carrying metal parts and between count input terminals and reset terminals Dielectric strength 1,000 VAC, 50/60 Hz for 1 min between current-carrying metal parts and exposed non-current-carrying metal parts and between the backlight power supply terminal and count input terminals/ reset terminals for backlight models 3,700 VAC, 50/60 Hz for 1 min between 1,000 VAC, 50/60 Hz for 1 min between current-carrying metal parts and excurrent-carrying metal parts and exposed non-current-carrying metal parts posed non-current-carrying metal parts 2,200 VAC, 50/60 Hz for 1 min between reset terminals and exposed non-current-carrying metal parts and between count input terminals and reset terminals Impulse withstand voltage 4.5 kV between current-carrying termi- 4.5 kV between current-carrying termi- 4.5 kV between current-carrying terminal and exposed non-current-carrying nal and exposed non-current-carrying nal and exposed non-current-carrying metal parts metal parts metal parts 3 kV between input terminals and reset terminals Noise immunity Square-wave noise generated by noise simulator (pulse width: 100 ns/1 µs, 1-ns rise) ±600 V (Between count input terminals/ ±1.5 kV (Between count input termiBetween reset terminals) nals) ±480 V (Between the backlight power ±500 V (Between reset terminals) supply terminals for backlight models) Static immunity ±500 V (Between count input terminals/ Between reset terminals) ±8 kV (malfunction) Vibration resistance Malfunction: 0.15-mm single amplitude at 10 to 55 Hz for 10 min each in 3 directions Destruction: 0.375-mm single amplitude at 10 to 55 Hz for 2 hrs each in 3 directions Shock resistance Malfunction: 200 m/s2 3 times each in 6 directions Destruction: 300 m/s2 3 times each in 6 directions EMC (EMI) Emission Enclosure: (EMS) Immunity ESD: EN61326 EN55011 Group 1 class B EN61326 EN61000-4-2: 4 kV contact discharge (level 2) 8 kV air discharge (level 3) Immunity RF-interference from AM Radio Waves: EN61000-4-3: 10 V/m (80 MHz to 1 GHz) (level 3) Immunity RF-interference from Pulse-modulated Radio Waves: EN61000-4-3: 10 V/m (900 MHz ± 5 MHz) (level 3) Immunity Conducted Disturbance: EN61000-4-6: 10 V (0.15 to 80 MHz) (level 3) Immunity Burst: EN61000-4-4: 2 kV power line (level 3) 2 kV I/O signal line (level 4) Degree of protection Front panel: IP66, NEMA4 Terminal block: IP20 Weight (see note) No-backlight model: Approx. 60 g Backlight model: Approx. 65 g Approx. 60 g Approx. 60 g Note: Weight includes waterproof packing and flush mounting bracket. ■ Reference Value Item Battery life Value Note 7 years min. with continuous input at 25°C The battery life is calculated according to the conditions in the left column and (lithium battery) therefore is not a guaranteed value. Use these value as reference for maintenance or replacement. Self-powered Total Counter H7EC C-11 Counters Item Connections ■ Terminal Arrangement Bottom view: View of the Total Counter rotated horizontally 180° Backlight Model No-backlight Model Backlight 24 VDC Count input Count input Reset input Reset input ■ Connections H7EC Total Counter PNP/NPN Universal DC Voltage Input Model With Backlight 1. Contact Input (Input by a Relay or Switch Contact) Relay Backlight 24 VDC Relay 2. Solid-state Input Open collector of a PNP transistor Input Input or Switch Backlight 24 VDC* Open collector of a PNP transistor Reset Reset or Switch or Open collector of an NPN transistor or Open collector of an NPN transistor Note: 1. Terminals 2 and 4 (input circuit and reset circuit) are functionally isolated. 2. Select input transistors according to the following: Dielectric strength of the collector ≥ 50 V Leakage current < 100 µA Note: *Recommended Power supply; eg. OMRON S8VS C-12 Self-powered Total Counter H7EC PNP/NPN Universal DC Voltage Input Model Without Backlight No-voltage Input Model 1. Contact Input (Input by a Relay or Switch Contact) 1. Contact Input (Input by a Relay or Switch Contact) Relay Relay Relay Relay Input Input Reset Reset or Switch Counters Terminals 2 and 4 are internally connected. or Switch or Switch or Switch Note: Use Relays and Switches that have high contact reliability because the current flowing from terminals 1 or 3 is small. It is recommended that OMRON's G3TAIA/ID be used as the SSR. 2. Solid-state Input Open collector of a PNP transistor Open collector of a PNP transistor Input 2. Solid-state Input (Open Collector Input of an NPN Transistor) Reset Open collector of an NPN transistor Input or Open collector of an NPN transistor Reset Terminals 2 and 4 are internally connected. or Open collector of an NPN transistor Note: 1. Terminals 2 and 4 (input circuit and reset circuit) are functionally isolated. 2. Select input transistors according to the following: Dielectric strength of the collector ≥ 50 V Leakage current < 100 µA Open collector of an NPN transistor or Switch Note: 1. Residual voltage in the output section of Proximity Sensors or Photoelectric Sensors becomes less than 0.5 V because the current flowing from terminals 1 or 3 is small thus allowing easy connection. 2. Select input transistors according to the following: Dielectric strength of the collector ≥ 50 V Leakage current < 1 µA AC/DC Multi-voltage Input Model Relay Input or Switch Reset Relay or Switch or Open collector of an NPN transistor Note: Select input transistors according to the following: Dielectric strength of the collector ≥ 50 V Leakage current < 1 µA Self-powered Total Counter H7EC C-13 Operation ■ Operating Modes H7EC Total Counter Incrementing Operation (Up) Reset Count input Full-scale (Full-scale −1) Counting display values Nomenclature Front view H7EC Key-protect Switch The Reset Key is not operable while the key-protect switch is set to ON. Counting speed switch For all models except for H7EC-NFV-@. If the counting speed setting is changed, the present value will not be held and so press the Reset Key on the front panel. Setting (see note) Counting speed Front panel Concave side Concave side 30 Hz (default setting) 1 kHz Terminal block Note: Perform switch setting before mounting to a control panel. C-14 Self-powered Total Counter H7EC Reset Key Reset the count value. Not operable under key-protect. Setting (see note) Bottom view Key-protect Front panel Concave side OFF (default setting) Concave side ON Terminal block Dimensions Note: All units are in millimeters unless otherwise indicated. H7EC-N Counters M3.5 terminal screw Panel Cutout Separate mounting 40 min. 45+0.5 0 22.2+0.5 0 Dimensions with Flush Mounting Bracket Dense mounting +1.0 (48 Units − 2.5) 0 22.2+0.5 0 Waterproofing is not possible for dense mounting • When mounting, insert the Counter into the cutout, insert the adapter from the back and push in the Counter while making the gap between the front panel and the cutout panel as small as possible. Use screws to secure the Counter. If waterproofing is desired, insert the waterproof packing. • When several Counters are installed, ensure that the ambient temperature will not exceed specifications. • The appropriate thickness of the panel is 1 to 5 mm. Note: A Compact Flush Mounting Bracket (Y92F-35) can also be used. Refer to Accessories for details. Self-powered Total Counter H7EC C-15 C-16 Self-powered Total Counter H7EC Self-powered Time Counter H7ET Counters • Seven digits, time range 0 to 3999d23.9h. • Dual time range: 999999.9 ←→ 3999d23.9h or 999h59m59s ←→ 9999h59.9m Model Number Structure ■ Model Number Legend H7ET - N 1 2 3 4 1. Count Input None: No-voltage input V: PNP/NPN universal DC voltage input FV: AC/DC multi-voltage input 3. Case Color None: Light gray B: Black 4. Display None: 7-segment LCD without backlight H: 7-segment LCD with backlight 2. Time Range None: 999999.9h/3999d23.9h 1: 999h59m59s/9999h59.9m Ordering Information ■ Time Counters Timer input Display Time range 999999.9h ←→ 3999d23.9h (switchable) Light-gray body PNP/NPN universal DC volt- 7-segment LCD with backage input light H7ET-NV-H Black body H7ET-NV-BH 999h59min59s ←→ 9999h59.9min (switchable) Light-gray body H7ET-NV1-H Black body H7ET-NV1-BH 7-segment LCD H7ET-NV H7ET-NV-B H7ET-NV1 H7ET-NV1-B AC/DC multi-voltage input 7-segment LCD H7ET-NFV H7ET-NFV-B H7ET-NFV1 H7ET-NFV1-B No-voltage input 7-segment LCD H7ET-N H7ET-N-B H7ET-N1 H7ET-N1-B ■ Accessories (Order Separately) Lithium Battery Y92S-36 Wire-wrap Terminal (set of two terminals) Y92S-37 Compact Flush Mounting Bracket (See note.) Y92F-35 Flush Mounting Adapter 26 mm × 45.3 mm Y92F-75 27.5 mm × 52.5 mm Y92F-76 24.8 mm × 48.8 mm Y92F-77B Note: The New H7E models are supplied with a Y92F-34 Mounting Bracket. Self-powered Time Counter H7ET C-17 Specifications ■ General Item H7ET-NV-@ H7ET-NV-@H H7ET-NFV-@ H7ET-N-@ H7ET-NV1-@ H7ET-NV1-@H H7ET-NFV1-@ H7ET-N1-@ Operating mode Accumulating Mounting method Flush mounting External connections Screw terminals Reset External/Manual reset Display 7-segment LCD with or without backlight, zero suppression (character height: 8.6 mm) (see note 1) Number of digits 7 Time range 0.0h to 999999.9h ←→ 0.0h to 3999d23.9h (switchable with switch) 0s to 999h59min59s ←→ 0.0min to 9999h59.9min (switchable with switch) Timer input PNP/NPN univer- AC/DC multi-voltsal DC voltage in- age input put PNP/NPN univer- AC/DC multi-voltsal DC voltage in- age input put Case color Light gray or black (-B models) Attachment Waterproof packing, flush mounting bracket, time unit labels (see note 2) Approved standard UL863, CSA C22.2 No.14, Lloyds Conforms to EN61010-1/IEC61010-1 (pollution degree2/overvoltage category III) Conforms to VDE0106/P100 No-voltage input No-voltage input Note: 1. Only PNP/NPN universal DC voltage input models (-H models) have a backlight. 2. “-hours”, “-d-h”, “-h-m”, and “-h-m-s” labels are included. ■ Ratings Item H7ET-NV@-@ H7ET-NV@-@H H7ET-NFV@-@ H7ET-N@-@ Supply voltage Backlight model: 24 VDC (0.3 W max.) Not required (powered by built-in battery) (for backlight) No-backlight model: Not required (powered by built-in battery) Timer input High (logic) level: 4.5 to 30 VDC Low (logic) level: 0 to 2 VDC (Input impedance: Approx. 4.7 kΩ) Reset input High (logic) level: 24 to 240 VAC/VDC, 50/60 Hz Low (logic) level: 0 to 2.4 VAC/VDC, 50/ 60 Hz No voltage input Maximum short-circuit impedance: 10 kΩ max. Short-circuit residual voltage: 0.5 V max. Minimum open impedance: 750 kΩ min. Minimum pulse width 1s Reset system External reset and manual reset: Minimum signal width of 20 ms Terminal screw tightening torque 0.98 N·m max. Ambient tempera- Operating: -10°C to 55°C (with no condensation or icing) ture Storage: -25°C to 65°C (with no condensation or icing) Ambient humidity C-18 Operating: 25% to 85% Self-powered Time Counter H7ET No voltage input Maximum short-circuit impedance: 10 kΩ max. Short-circuit residual voltage: 0.5 V max. Minimum open impedance: 750 kΩ min. ■ Characteristics H7ET-NV@-@ H7ET-NV@-H@ H7ET-NFV@-@ H7ET-N@-@ Time accuracy ±100 ppm (25°C) Insulation resistance 100 MΩ min. (at 500 VDC) between current-carrying metal parts and exposed non-current-carrying metal parts, and between the backlight power supply and timer input terminals/reset terminals for backlight models 100 MΩ min. (at 500 VDC) between current-carrying metal parts and exposed non-current-carrying metal parts and between timer input terminals and reset terminals 100 MΩ min. (at 500 VDC) between current-carrying metal parts and exposed non-current-carrying metal parts Dielectric strength 1,000 VAC, 50/60 Hz for 1 min between current-carrying metal parts and exposed non-current-carrying metal parts and between the backlight power supply and timer input terminals/reset terminals for backlight models 3,700 VAC, 50/60 Hz for 1 min between timer input terminals and exposed noncurrent-carrying metal parts 2,200 VAC, 50/60 Hz for 1 min between reset terminals and exposed non-current-carrying metal parts and between timer input terminals and reset terminals 1,000 VAC, 50/60 Hz for 1 min between current-carrying metal parts and exposed non-current-carrying metal parts Impulse withstand voltage 4.5 kV between current-carrying termi- 4.5 kV between current-carrying termi- 4.5 kV between current-carrying terminal and exposed non-current-carrying nal and exposed non-current-carrying nal and exposed non-current-carrying metal parts metal parts metal parts 3 kV between timer input terminals and reset terminals Square-wave noise generated by noise simulator (pulse width: 100 ns/1 µs, 1-ns rise) Noise immunity ±600 V (Between timer input terminals/ ±1.5 kV (Between timer input termiBetween reset terminals) nals) ±480 V (Between the backlight power ±500 V (Between reset terminals) supply terminals for backlight models) ±500 V (Between timer input terminals/ Between reset terminals) Static immunity ±8 kV (malfunction) Vibration resistance Malfunction: 0.15-mm single amplitude at 10 to 55 Hz for 10 min each in 3 directions Destruction: 0.375-mm single amplitude at 10 to 55 Hz for 2 hrs each in 3 directions Shock resistance Malfunction: 200 m/s2 3 times each in 6 directions Destruction: 300 m/s2 3 times each in 6 directions EMC (EMI) Emission Enclosure: (EMS) Immunity ESD: Degree of protection Front panel: IP66, NEMA4 with waterproof packing Terminal block: IP20 Weight (see note) No-backlight model: Approx. 60 g Backlight model: Approx. 65 g EN61326 EN55011 Group 1 class B EN61326 EN61000-4-2: 4 kV contact discharge (level 2) 8 kV air discharge (level 3) Immunity RF-interference from AM Radio Waves: EN61000-4-3: 10 V/m (80 MHz to 1 GHz) (level 3) Immunity RF-interference from Pulse-modulated Radio Waves: EN61000-4-3: 10 V/m (900 MHz ± 5 MHz) (level 3) Immunity Conducted Disturbance: EN61000-4-6: 10 V (0.15 to 80 MHz) (level 3) Immunity Burst: EN61000-4-4: 2 kV power line (level 3) 2 kV I/O signal line (level 4) Approx. 60 g Approx. 60 g Note: Weight includes waterproof packing and flush mounting bracket. ■ Reference Value Item Battery life Value 10 years min. with continuous input at 25°C (lithium battery) Note The battery life is calculated according to the conditions in the left column and therefore is not a guaranteed value. Use these value as reference for maintenance or replacement. Self-powered Time Counter H7ET C-19 Counters Item Connections ■ Terminal Arrangement Bottom view: View of the Time Counter rotated horizontally 180° Backlight Model No-backlight Model Backlight 24 VDC Timer input Timer input Reset input Reset input ■ Connections H7ET Time Counter PNP/NPN Universal DC Voltage Input Model With Backlight 1. Contact Input (Input by a Relay or Switch Contact) Relay Relay 2. Solid-state Input Open collector of a PNP transistor Backlight 24 VDC Input Input or Switch Open collector of a Backlight PNP transistor 24 VDC* Reset Reset or Switch or Open collector of an NPN transistor or Open collector of an NPN transistor Note: 1. Terminals 2 and 4 (input circuit and reset circuit) are functionally isolated. 2. Select input transistors according to the following: Dielectric strength of the collector ≥ 50 V Leakage current < 1 µA Note: *Recommended power supply; eg. OMRON S8VS C-20 Self-powered Time Counter H7ET PNP/NPN Universal DC Voltage Input Model Without Backlight No-voltage Input Model 1. Contact Input (Input by a Relay or Switch Contact) Relay 1. Contact Input (Input by a Relay or Switch Contact) Relay Relay Input Input Relay Reset Reset or Switch or Switch Counters Terminals 2 and 4 are internally connected. or Switch or Switch 2. Solid-state Input Open collector of a PNP transistor Open collector of a PNP transistor Input Note: Use Relays and Switches that have high contact reliability because the current flowing from terminals 1 or 3 is as small as approx. 10 µA. It is recommended that OMRON's G3TA-IA/ID be used as the SSR. 2. Solid-state Input (Open Collector Input of an NPN Transistor) Reset Open collector of an NPN transistor Input or Open collector of an NPN transistor or Open collector of an NPN transistor Note: 1. Terminals 2 and 4 (input circuit and reset circuit) are functionally isolated. 2. Select input transistors according to the following: Dielectric strength of the collector ≥ 50 V Leakage current < 1 µA Reset Terminals 2 and 4 are internally connected. Open collector of an NPN transistor or Switch Note: 1. Residual voltage in the output section of Proximity Sensors or Photoelectric Sensors becomes less than 0.5 V because the current flowing from terminals 1 or 3 is as small as approx. 10 µA, thus allowing easy connection. 2. Select input transistors according to the following: Dielectric strength of the collector ≥ 50 V Leakage current < 1 µA AC/DC Multi-voltage Input Model Relay Input or Switch Reset Relay or Switch or Open collector of an NPN transistor Self-powered Time Counter H7ET C-21 Operation ■ Operating Modes H7ET Time Counter Incrementing Operation (Up) Reset Timer input Internal clock timer value Full-scale (Full-scale −0.1 (1)) Timer display values Nomenclature Front view H7ET Time-range switch If the time-range setting is changed, the present value will not be held and so press the Reset Key on the front panel. Reset Key Reset the count value. Not operable under key-protect. Key-protect Switch The Reset Key is not operable while the key-protect switch is set to ON. Setting (see note) Key-protect Front panel Setting (see note) Time range H7ET-N@@-@@ H7ET-N@@1-@@ 0.0h to 3999d23.9h 0s to 999h59min59s (default setting) Bottom view Concave side OFF (default setting) Concave side ON Front panel Concave side Terminal block Concave side 0.0h to 999999.9h (default setting) 0.0min to 9999h59.9min Terminal block Note: Perform switch setting before mounting to a control panel. C-22 Self-powered Time Counter H7ET Dimensions Note: All units are in millimeters unless otherwise indicated. Counters H7ET-N Panel Cutout Separate mounting 40 min. 45+0.5 0 Dimensions with Flush Mounting Bracket 22.2+0.5 0 Dense mounting +1.0 (48 Units − 2.5) 0 22.2+0.5 0 Waterproofing is not possible for dense mounting • When mounting, insert the Counter into the cutout, insert the adapter from the back and push in the Counter while making the gap between the front panel and the cutout panel as small as possible. Use screws to secure the Counter. If waterproofing is desired, insert the waterproof packing. • When several Counters are installed, ensure that the ambient temperature will not exceed specifications. • The appropriate thickness of the panel is 1 to 5 mm. Note: A Compact Flush Mounting Bracket (Y92F-35) can also be used. Refer to Accessories for details. Self-powered Time Counter H7ET C-23 C-24 Self-powered Time Counter H7ET Self-powered Tachometer H7ER Counters • Revolutions displayed up to five digits. • Dual revolution display according to encoder resolution used; 1000 s-1/1000 min-1 or 1000.0 s-1 /1000.0 min-1 • Switchable dual revolution display type available (-NV1 models); extended up to 10000 min-1 Model Number Structure ■ Model Number Legend H7ER - N 1 2 3 4 1. Count Input None: No-voltage input V: PNP/NPN universal DC voltage input 2. Number of Digits None: 4 digits 1: 5 digits 3. Case Color None: Light gray B: Black 4. Display None: 7-segment LCD without backlight H: 7-segment LCD with backlight Ordering Information ■ Tachometers Count input Display Max. revolutions displayed (applicable encoder resolution) 1000 s-1 (1 pulse/rev.), 1000 min-1 (60 pulse/rev.) Light-gray body PNP/NPN universal 7-segment LCD DC voltage input with backlight No-voltage input 1000.0 s-1 (10 pulse/rev.), 1000.0 min-1 (600 pulse/rev.) ←→ 10000 min-1 (60 pulse/rev.) (switchable) Black body Light-gray body Black body H7ER-NV-H H7ER-NV-BH H7ER-NV1-H H7ER-NV1-BH 7-segment LCD H7ER-NV H7ER-NV-B H7ER-NV1 H7ER-NV1-B 7-segment LCD H7ER-N H7ER-N-B --- --- ■ Accessories (Order Separately) Lithium Battery Y92S-36 Wire-wrap Terminal (Set of two Terminals) Y92S-37 Compact Flush Mounting Bracket (See note.) Y92F-35 Flush Mounting Adapter 26 mm × 45.3 mm Y92F-75 27.5 mm × 52.5 mm Y92F-76 24.8 mm × 48.8 mm Y92F-77B Note: The New H7E models are supplied with a Y92F-34 Mounting Bracket. Self-powered Tachometer H7ER C-25 Specifications ■ General Item H7ER-NV-@ H7ER-NV-@H H7ER-N-@ H7ER-NV1-@ H7ER-NV1-@H Operating mode Up type Mounting method Flush mounting External connections Screw terminals, Wire-wrap Terminals (see note 3) Display 7-segment LCD with or without backlight, zero suppression (character height: 8.6 mm) (see note 4) Number of digits 4 Count input PNP/NPN universal DC voltage input Max. counting speed 1 kHz 10 kHz Max. revolutions displayed (see note 5) 1,000 s-1 (When encoder resolution of 1 pulse/rev is used.) 1,000 min-1 (When encoder resolution of 60 pulse/rev is used.) 1,000.0 s-1 (When encoder resolution of 10 pulse/rev is used.) 1,000.0 min-1 (When encoder resolution of 600 pulse/ rev is used.) ←→ 10,000 min-1 (When encoder resolution of 60 pulse/rev is used.) (Switchable with switch) 5 No-voltage input PNP/NPN universal DC voltage input Attachment Waterproof packing, flush mounting bracket, revolution unit labels (see note 5) Approved standard UL863, CSA C22.2 No.14, Lloyds Conforms to EN61010-1/IEC61010-1 (Pollution degree2/overvoltage category III) Conforms to VDE0106/P100 Note: 1. 2. 3. 4. 5. Reset is not available. When there is no input, the display will be 0.0 or 0. Separately ordered Wire-wrap Terminals (Y92S-37) are required. Only PNP/NPN Universal DC voltage input models have a backlight. “rpm”, “rps”, “s-1” and “min-1” labels are included. ■ Ratings Item H7ER-NV@-@ H7ER-NV@-@H H7ER-N-@ Supply voltage Backlight model: 24 VDC (0.3 W max.) (for backlight Not required (powered by built-in battery) lit) No-backlight model: Not required (powered by builtin battery) Count input High (logic) level: 4.5 to 30 VDC Low (logic) level: 0 to 2 VDC (Input impedance: Approx. 4.7 kΩ) No voltage input Maximum short-circuit impedance: 10 kΩ max. Short-circuit residual voltage: 0.5 V max. Minimum open impedance: 750 kΩ min. Max. counting speed 4-digit models:1 kHz 5-digit models:10 kHz 1 kHz Minimum signal width 10 kHz: 0.05 ms 1 kHz: 0.5 ms Terminal screw tightening torque 0.98 N·m max. Ambient temperature Operating: -10°C to 55°C (with no condensation or icing) Storage: -25°C to 65°C (with no condensation or icing) Ambient humidity Operating: 25% to 85% C-26 Self-powered Tachometer H7ER ■ Characteristics H7ER-NV@-@ H7ER-NV@-@H H7ER-N-@ Insulation resistance 100 MΩ min. (at 500 VDC) between current-carrying 100 MΩ min. (at 500 VDC) between current-carrying metal parts and exposed non-current-carrying metal metal parts and exposed non-current-carrying metal parts, and between the backlight power supply and parts count input terminals/reset terminals for backlight models Dielectric strength 1,000 VAC, 50/60 Hz for 1 min between current-car- 1,000 VAC, 50/60 Hz for 1 min between current-carrying metal parts and exposed non-current-carrying rying metal parts and exposed non-current-carrying metal parts and between the backlight power supply metal parts and count input terminals/reset terminals for backlight models Impulse withstand voltage 4.5 kV between current-carrying terminal and exposed non-current-carrying metal parts Noise immunity Square-wave noise generated by noise simulator (pulse width: 100 ns/1 µs, 1-ns rise) ±600 V (Between count input terminals) ±480 V (Between the backlight power supply terminals for backlight models) ±500 V (Between count input terminals) Static immunity ±8 kV (malfunction) Vibration resistance Malfunction: 0.15-mm single amplitude at 10 to 55 Hz for 10 min each in 3 directions Destruction: 0.375-mm single amplitude at 10 to 55 Hz for 2 hrs each in 3 directions Shock resistance Malfunction: 200 m/s2 3 times each in 6 directions Destruction: 300 m/s2 3 times each in 6 directions EMC (EMI) Emission Enclosure: (EMS) Immunity ESD: Degree of protection Front panel: IP66, NEMA4 with waterproof packing Terminal block: IP20 Weight (see note) No-backlight model:Approx. 60 g Backlight model: Approx. 65 g EN61326 EN55011 Group 1 class B EN61326 EN61000-4-2: 4 kV contact discharge (level 2) 8 kV air discharge (level 3) Immunity RF-interference from AM Radio Waves: EN61000-4-3: 10 V/m (80 MHz to 1 GHz) (level 3) Immunity RF-interference from Pulse-modulated Radio Waves: EN61000-4-3: 10 V/m (900 MHz ± 5 MHz) (level 3) Immunity Conducted Disturbance: EN61000-4-6: 10 V (0.15 to 80 MHz) (level 3) Immunity Burst: EN61000-4-4: 2 kV power line (level 3) 2 kV I/O signal line (level 4) Note: Weight includes waterproof packing and flush mounting bracket. ■ Reference Value Item Battery life Value Note 7 years min. with continuous input at 25°C The battery life is calculated according to the conditions in the left column and (lithium battery) therefore is not a guaranteed value. Use these value as reference for maintenance or replacement. Self-powered Tachometer H7ER C-27 Counters Item Connections ■ Terminal Arrangement Bottom view: View of the Tachometer rotated horizontally 180° Backlight Model No-backlight Model Backlight 24 VDC Pulse input Pulse input ■ Connections H7ER Tachometer Note: Select input transistors according to the following: Dielectric strength of the collector ≥ 50 V Leakage current < 100 µA (1 µA for no-voltage input model) PNP/NPN Universal DC Voltage Input Models With Backlight No-voltage Input Model Transistor Input Transistor Input (Open Collector of an NPN Transistor) Open collector of or an NPN transistor Open collector of an NPN transistor Open collector of an PNP transistor Backlight 24 VDC* Input *Recommended power supply; eg. OMRON S8VS PNP/NPN Universal DC Voltage Input Models Without Backlight Transistor Input Open collector of or an NPN transistor Open collector of an PNP transistor Input C-28 Self-powered Tachometer H7ER Input Operation ■ Operating Modes H7ER Tachometer Counters Incrementing Operation Within Unit Time (Up) Count period Count period 0.25 s (1 s) (1 s) Internal gate Display refreshed Counter reset Refresh Internal count value Number display Previous count value display Display refreshed every 1.25 s Display refreshed every 1.25 s Nomenclature Front view H7ER Not used Counting speed switch For H7ER-NV1-@@ Bottom view Counting Speed Switch Settings and Unit Label Application Model Counting speed switch setting (see note) Max. revolutions displayed Applicable encoder resolution Applicable unit label 10000 min-1 (default setting) 60 pulse/rev. "min-1" or "rpm" 1000.0 min-1 600 pulse/rev. "min-1" or "rpm" 1000.0 s-1 10 pulse/rev. "s-1" or "rps" 1000 min-1 60 pulse/rev. "min-1" or "rpm" 1000 s-1 1 pulse/rev. "s-1" or "rps" Front panel H7ER-NV1-@@ Concave side Concave side Terminal block H7ER-N-@ H7ER-NV-@@ No setting is required Note: Perform switch setting before mounting to a control panel. Self-powered Tachometer H7ER C-29 Dimensions Note: All units are in millimeters unless otherwise indicated. H7ER-N Panel Cutout Separate mounting 40 min. 45+0.5 0 22.2+0.5 0 Dimensions with Flush Mounting Bracket Dense mounting +1.0 (48 Units − 2.5) 0 22.2+0.5 0 Waterproofing is not possible for dense mounting • When mounting, insert the Counter into the cutout, insert the adapter from the back and push in the Counter while making the gap between the front panel and the cutout panel as small as possible. Use screws to secure the Counter. If waterproofing is desired, insert the waterproof packing. • When several Counters are installed, ensure that the ambient temperature will not exceed specifications. • The appropriate thickness of the panel is 1 to 5 mm. Note: A Compact Flush Mounting Bracket (Y92F-35) can also be used. Refer to Accessories for details. C-30 Self-powered Tachometer H7ER PCB-mounting Counters H7E@-N@P Counters • Dedicated for use on PCB. • Total Counters and Time Counter available. Model Number Structure ■ Model Number Legend H7E -N 1 P 2 1. Function C: Total Counter T: Time Counter 2. Max. Counting Speed for H7EC Models None: 1 kHz L: 30 Hz Ordering Information ■ PC Board-use Counters Count input Display Total counter Time counter Max. counting speed 1 kHz No-voltage input 7-segment LCD H7EC-NP 30 Hz H7EC-NLP H7ET-NP ■ Accessory (Order Separately) Connecting Socket (28-pin) XR2A-2801-N PCB-mounting Counters H7E@-N@P C-31 Specifications ■ General Item Total Counter H7EC-NP Time Counter H7EC-NLP Operating mode Up type Mounting method Direct mounting on PC Board or mounting on 28-pin socket Reset External reset, Power-OFF reset Number of digits 8 Time range --- Max. counting speed 1 kHz Count/Timer input No-voltage input Display 7-segment LCD (character height: 8.6 mm) Case color Transparent Approved standard UL863, CSA C22.2 No.14 H7ET-NP 7 0.0h to 999999.9h 30 Hz --- ■ Ratings Item H7EC-NP H7EC-NLP Supply voltage 3 VDC (2.7 to 3.3 VDC) Count/Timer input No voltage input Maximum short-circuit impedance: 10 kΩ max. Short-circuit residual voltage: 0.5 V max. Minimum open impedance: 750 kΩ min. Reset input H7ET-NP Max. counting speed (see note) 1 kHz: Minimum signal width of 0.5 ms 30 Hz: Minimum signal width of 16.7 ms --- Minimum signal input width --- 1s Reset system External reset: Minimum signal width of 20 ms Power-OFF reset: Minimum power OFF time of 500 ms Ambient temperature Operating: -10°C to 55°C (with no condensation or icing) Storage: -25°C to 65°C (with no condensation or icing) Ambient humidity Operating: 25% to 85% Note: ON/OFF ratio 1:1 ■ Characteristics Item H7EC-NP H7EC-NLP H7ET-NP ±100 ppm (25°C) Time accuracy --- Noise immunity Square-wave noise generated by noise simulator (pulse width: 100 ns/1 µs, 1-ns rise) ±500 V (Between count or timer input terminals/Between reset terminals) Static immunity ±8 kV (malfunction) Vibration resistance Malfunction:0.15-mm single amplitude at 10 to 55 Hz for 10 min each in 3 directions Destruction:0.375-mm single amplitude at 10 to 55 Hz for 2 hrs each in 3 directions Shock resistance Malfunction:200 m/s2 3 times each in 6 directions Destruction:300 m/s2 3 times each in 6 directions EMC (EMI) Emission Enclosure: (EMS) Immunity ESD: EN61326 EN55011 Group 1 class B EN61326 EN61000-4-2: 4-kV contact discharge (level 2) 8-kV air discharge (level 3) Immunity RF-interference from AM Radio Waves: EN61000-4-3: 10 V/m (80 MHz to 1 GHz) (level 3) Immunity RF-interference from Pulse-modulated Radio Waves: EN61000-4-3: 10 V/m (900 MHz ± 5 MHz) (level 3) Immunity Conducted Disturbance (see note):EN61000-4-6: 10 V (0.15 to 80 MHz) (level 3) Immunity Burst (see note): EN61000-4-4: 2-kV I/O signal line (level 4) Weight Approx. 20 g Note: The power supply terminals of the H7E@-N@P are considered as 3-VDC control terminals. C-32 PCB-mounting Counters H7E@-N@P Connections ■ Terminal Arrangement Reset input 3-VDC external power supply H7ET-NP Reset input Count input Timer input Counters 3-VDC external power supply H7EC-N@P ■ Connections Power Supply and Battery Connections C is a film capacitor, of about 0.1 µF, and is intended to absorb noise induced by the power lines. Battery Connections 3-V battery Keep the wiring between the H7E@-N@P and R2 or C as short as possible (within 50 mm). H7E@-N@P Backup Circuit for Protection Against Power Failure When designing a circuit, keep the power wiring connections shorter than 50 mm. Refer to the connection diagram above for the proper wiring polarity. H7E@-N@P The life expectancy of a battery power supply can be calculated by the following formula: 3-V battery t = A/lc Where, t: Life expectancy of battery (h) A: Battery capacity (mAh) lc: H7E@-N@P current consumption (mA) Backup circuit Use a diode (D) having a forward voltage as small as possible (0.1 V max. at IF of 20 µA). Example: Battery life when using a 3-V lithium battery with a capacity of 1,200 mAh for the H7E@-N@P. t = 1,200 [mAh]/20 × 10-3 [mA] = 60,000 hours (approx. 6.8 years) The battery capacity varies depending on the type of battery used; oxidized silver, mercury, or lithium battery. Determine the ratio of R1 to R2 in accordance with the forward voltage of the diode to be used. Be aware that when the power supplied to the H7E@-N@P has dropped to less than the voltage of the backup circuit, the battery will discharge. To protect the circuit against a momentary power failure, an aluminum electrolyte capacitor can be used in place of a battery, as shown below: Voltage Division of Power Supply Circuit H7E@-N@P When necessary, the voltage from the battery may be divided by resistances: Backup circuit H7E@-N@P When a capacitor is used, its backup time can be calculated by the following formula: t = C (V1 - V2) / Ic When doing so, however, ensure that the following equation balances: E (V) × R2 / (R1 + R2) = 3 V R E Where, t: Backup time (s) C: Capacitance (µF) V1: Supply voltage before power failure (V) V2: Minimum operating voltage of H7E@-N@P (V) Ic: H7E@-N@P current consumption (µA) R1 2 kΩ 9.1 kΩ 33 kΩ Example: Backup time by an aluminum electrolytic capacitor of 100 µF. (Minimum operating voltage of H7E@-N@P is 2.6 V.) R2 3 kΩ 3 kΩ 4.7 kΩ t = 100 µF × (3-2.6 V)/20 µA = 100 × 0.40/20 = 2.0 seconds 5V 12 V 24 V Allow a current high enough to flow through R1 so that the H7E@N@P receives sufficient current. PCB-mounting Counters H7E@-N@P C-33 Note that the above calculation provides an approximate value, which varies depending on the environment under which the Counter is used and also on the type of capacitors used. Provide some allowance in selecting capacitors. Solid State Input Keep the wiring between the H7E@-N@P and R2 or C as short as possible (within 50 mm). H7E@-N@P Open-collector Transistor Input Input Connections Input Connection Contact Input Reset input Count/Timer input TTL or C-MOS IC Input Relay Relay H7E@-N@P Reset input TTL or C-MOS IC H7E@-N@P TTL or C-MOS IC Count/Timer input Or Reset input Or Count/Timer input Use a transistor for input that satisfies the following conditions: Collector breakdown voltage ≥ 50 V Leakage current < 1 µA Use a diode (D) having a forward voltage as small as possible (0.1 V max. at IF of 20 µA). When the H7EC-NP is used, relay chattering may be counted. Use the H7EC-NLP, one of the low-speed input models. Operation ■ Operating Modes H7EC Total Counter H7ET Time Counter Incrementing Operation (Up) Incrementing Operation (Up) Reset Reset Count input Timer input Full-scale (Full-scale −1) Internal clock timer value Full-scale (Full-scale −0.1 Counting display values Timer display values Dimensions Note: All units are in millimeters unless otherwise indicated. Flush Mounting H7EC-N@P DIP Terminal PCB Processing Dimensions (Soldering Surface) Section occupied by the Counter DIP terminal x 8 Eight, 0.8 dia. Base 17.3 max. Flush Mounting H7ET-NP 43 C-34 PCB-mounting Counters H7E@-N@P Note: Processing dimensions are for 28-pin IC socket. Accessories (Order Separately) (Common) ■ New H7E (Except for PCB-mounting Counter) The New H7E models are supplied with a mounting bracket (Y92F-34) and nut. Additionally, the Y92F-75/-76/-77B Flush Mounting Adapters shown here allow the New H7E models to be fitted to existing panel cutouts. Y92F-35 Compact Flush Mounting Bracket Single mounting 47.6 2.4 18.6 Dense 4 − × Counters Panel Cutout ounting +1.0 0 26 +0.5 0 22.2 30 min. RST 22.2 +0.5 0 +0.5 0 45 Degree of protection (front): IP40 (not waterproof) The Y92F-76 adapter can be used. The DIP switch of the H7E@-N can be operated in mounted condition. Vibration resistance and shock resistant are the same level as the H7E@-N series. • The minimum mounting interval is 30 mm. Note: An interval of 40 mm is recommended for easier wiring. • Do not allow the ambient temperature of the H7E@-N to exceed the specifications (55°C). • Mounting is possible onto panels with a thickness of 1 to 5 mm. Y92F-75 Flush Mounting Adapter for 26 × 45.3 Rectangular Cutout Use mounting bracket supplied with the Counter Two 3.5 dia. mounting holes Panel Cutout Two, M3 26 31 24.2 22.2 26 4 45.2 48.2 63 72 (Color: light gray) 45.3 63 Y92F-76 Flush Mounting Adapter for 27.5 × 52.5 Rectangular Cutout Panel Cutout Two 4.5 dia. countersunk holes Two, M4 50 38 24.2 22.2 38 27.5 RST (Color: light gray) Use the Y92F-76 together with the Y92F-35 Compact Flush Mounting Bracket. 52.5 4 45.2 48.2 60 Y92F-77B Flush Mounting Adapter for 24.8 × 48.8 Rectangular Cutout Use mounting bracket supplied with the Counter Panel cutout 24.8 28.8 24.2 22.2 (Color: light gray) 45.2 48.2 53.8 Self-powered Totalizer 4 48.8 Note: The mounting panel thickness should be between 1 and 5 mm. New H7E (Common) C-35 Y92S-37 Wire-wrap Terminal (Set of Two Terminals) 44.8 Wire-wrap terminal (1 × 1 mm) 22 24 2 48 When using the Wire-wrap Terminal, be sure to use the correct wires and peripheral devices. (The correct wires, bits and sleeves are shown in the table on the right.) Y92S-36 Lithium Battery (3 V) Wire Wrapped state 2-A 2-B Normal AWG24 1-A 1-B Normal AWG26 3-A 1-B Normal 24.5 dia. ■ PCB-mounting Counters XR2A-2801-N 28-pin Socket Note: When using the Socket, use the PCB processing dimensions previously provided. Self-powered Totalizer New Sleeve 17.1 AWG22 7.7 C-36 Bit 48.5 5 H7E (Common) Precautions (Common) ■ New H7E (Except for PCB-mounting Counter) !Caution !Caution If a voltage other than the rated one is applied, internal elements may be damaged. Do not use the Counter in the following places: • Locations subject to direct sunlight. • Locations subject to corrosive gases. • Locations subject to dust. Do not use any battery other than the specified one (Y92S-36). Using another battery may cause liquid leakage or breakage, resulting in malfunction or injury. Before Use Reset Input and Count/Timer Input • An insulation sheet has been inserted to maintain the quality of the Totalizer in the event of a long period without use. Be sure to remove this sheet before attempting to use the product. Remove the insulation sheet and press the Reset Key on the front panel of the Counter. (With the H7ER-N,-NV(-H),-NV1(-H), models, “0” or “0.0” will be displayed after 1 s.) • The H7E operates using its built-in Battery. If the H7E is connected to a device that has +V and OUT terminals that are connected with a diode as shown in the circuit diagram, the circuit indicated by the arrow 1 or 2 will be formed when the device is turned OFF. As a result, the H7E may be reset or count by one. It is recommended that such devices not be connected to the H7E. Devices Insulation Sheet Internal circuit H7E@-N Count/Timer input or reset input Reset Key • Switch settings on the Counter must be performed before mounting it to a control panel. • Do not use the Counter in the following locations: • Locations subject to severe changes in temperature. • If an excessive voltage is applied to the count/timer input or reset input terminals, the internal elements may be damaged. Ensure that the following voltages are not exceeded: • PNP/NPN universal voltage input model: 30 VDC • Locations subject to condensation as the result of high humidity. • AC/DC voltage input model: At count/timer input: 240 VAC (peak voltage: 338V) 240 VDC At reset input: No voltage can be applied. (No-voltage input) • No-voltage input model: No voltage can be applied. Mounting Precautions for Flush Mounting Although the operating section is watertight (conforming to NEMA4, IP66), rubber packing is provided to avoid water leakage through the gap between the Counter and panel cutout. Unless this rubber packing is tightly squeezed on, water may permeate inside the panel. Therefore, be sure to tighten the screws for fixing the Y92F-34 Flush Mounting Bracket. (Excessive tightening may also deform the rubber packing.) Screw for the Flush Mounting Bracket The wider side must face the panel. • Avoid wiring close to high-tension or large-current lines. • Do not remove the outer case when voltage is being applied to the power supply terminals or the input terminals. • The input for the H7E@-NFV-@ is a high-impedance circuit and so influence from an induced voltage may result in malfunction. Therefore, when the input signal wiring is longer than 10 m (line capacitance of 120 pF/m, at room temperature), it is recommended that a CR filter or a bleeder resistor is connected. Y92F-34 Adapter Panel Self-powered Totalizer New H7E (Common) C-37 Counters !WARNING This product has a built-in lithium battery. Do not short-circuit the + and − terminals, charge, disassemble, deform, or expose the battery to fire. The battery may explode (break), catch fire, or cause liquid leakage. Count Input, Timer Input or Reset Input to More than One H7E Counter at a Time AC/DC Multi-voltage Input Models • When connecting count/timer input from an SSR to the Counter that operates with AC/DC voltage input, use OMRON’s G3TA-IA/ID SSR (for DC) whose leakage current is 0.1 mA max. or connect a bleeder resistor in parallel to the input circuit of the Counter. • PNP/NPN Universal DC Voltage Input or Leakage current: 0.1 mA max. or or or *Bleeder resistor The voltage between terminals 1 and 2 must be 1.5 V maximum when the SSR is OFF. Backlight Power Supply • To reduce variation in the brightness of the backlight when using more than one H7E with a backlight, use the same power supply for all the backlights. or Note: H (Reset ON) level must be 4.5 V minimum. 4.7 (kΩ)/N + V 4.7 (kΩ)/N + R • No-voltage Input H= • When connecting the DC power supply for the backlights, be sure to connect the polarities correctly. or Note: 1. The leakage current of the transistor used for input must be less than 1 µA. 2. The forward voltage of the diode must be as low as possible (i.e., 0.1 V maximum with an IF of 20 µA) so that the voltage between terminals 3 and 4 will be 0.5 V when the reset input is ON. Input and Power Supply No-voltage Input Models • Do not impose voltage on the Counter if the Counter is a model that operates with no-voltage input, otherwise the internal circuit of the Counter may be damaged. Do not connect any single input signal in parallel to Counter models operating with no-voltage input and those operating with voltage input, otherwise the Counters may malfunction. • When connecting a sensor to the Counter that operates with novoltage input, make sure that the sensor has open collector output. Input Verification with the H7ET Time Counter (When the time range is not set to 0s to 999h59min59s) The decimal point of the LCD blinks every other second while an input signal is being applied. If the decimal point is not blinking, the input signal is not being received correctly. Check the input signal connections. Unit Label for Time Counter and Tachometer A unit label has been packed with the Counter. Use in accordance with the application. Sensor Battery Replacement Remove the wiring when replacing the Battery. Do not come in contact with any item to which high voltage is being applied. Doing so may result in electric shock. • When connecting an open collector input from a transistor to the Counter that operates with no-voltage input, make sure that the leakage current of the transistor is 1 µA maximum. Before changing the Battery, the person should ensure that they are not carrying any static electric charge. No-voltage Input and PNP/NPN Universal DC Voltage Input Models 1. Using the tool, pry open the lift-tab on the case. (1) 2. Pull the body out of its outer case. (2) 3. Lift the Battery up by the edge and remove it. (3) When removing the Battery, do not come in contact with the display area or any internal parts. 4. Wipe the back of the new Battery before inserting it. 5. Ensure that the + and - terminals are correctly oriented. 6. After replacing the Battery, re-insert the body into its case. (4) Check that the case is securely held in by the lift-tab. • The operation of the Counter may be affected if the capacitance of input lines exceeds 500 pF (about 10 m, with parallel wires of 2 x 2 mm). Keep all wires as short as possible. When using shielded wire, line capacitance may occur. C-38 Self-powered Totalizer New Procedure for replacing the Battery (refer to the diagrams below): H7E (Common) 7. Press the Reset Key before use (not necessary for H7ER-N,-NV,NV1). (5) The count or timer input, reset input, and backlight power supply terminals of the no-voltage input or PNP/NPN universal DC voltage input models (H7E@-N,-N1, H7E@-NV(-H),-NV1(-H)) are not isolated. (2) A SELV power supply conforming to Appendix H of IEC61010-1 should be used for the count or timer input, reset input and backlight power supply terminals. A SELV power supply is a power supply for which the input and output have double or reinforced insulation, and for which the output voltage is 30 Vrms with 42.4 V peak or 60 VDC max. (Only the H7E@-NV@-H has a backlight.) Recommended 24VDC power supply; eg. OMRON S8VS. (1) Battery (3) The terminals for count or timer input and reset input for AC/DC multi-voltage input models have basic insulation. Connect the reset input terminals to a device that does not have exposed current-carrying parts and has basic insulation for 240 VAC. (4) Others If the indicator keeps flickering or is OFF, the internal battery may be close to the end of its service life. In such a case, it is suggested that the battery be replaced. (5) ■ PCB-mounting Counter Power Supply Battery Replacement • Use the power supply within the applicable range indicated by the following waveform, while considering the ripple and voltage fluctuations of the circuit power source. To prevent unwanted reset when replacing the battery, connect the new battery before disconnecting the old one. Otherwise, the voltage supplied to the counter circuit drops, causing the present count value to reset. 3.6 V Voltage When designing the circuit board, providing two extra terminals for battery connection will make the switch must simpler. See the schematic diagram below: 2.6 V • The H7E@-N@P changes its mode as shown below depending on the applied supply voltage. LCD (V) 3.6 3 Approx. 2.6 Approx. 2.2 Internal circuit operation Beyond supply voltage Looks darker Looks normal H7E@-N@P Normal operation Flashes Normal operation No display No operation Applicable range Wiring polarity must be carefully observed, in order to prevent permanent damage to the Counters. Exercise caution when inserting the Counter in the socket, to prevent reversed polarity. Battery life guideline 0 Self-powered Totalizer New H7E (Common) C-39 Counters Tool (1) EN/IEC Standards Inputs PC Board (Bad Example) Do not route the wiring of the count, timer, or reset inputs in the vicinity of, or in parallel to the wiring of high-voltage or inductive load circuits (such as motors and relays). Also, keep the wiring as short as possible. PC Board (Good Example) H7E@-N@P Large-currentconsuming components Placed far away from the power supply. Large-currentconsuming components Wired in parallel with large-currentcarrying components. H7E@-N@P Bypass capacitor H7E@-N@P Power supply Be careful not to apply voltages exceeding the following values to the count, timer, or reset terminals, otherwise the internal circuit may be damaged. Bypass capacitor Power supply When using the Counter in an environment where the Counter is subject to frequent occurrences of vibration or shock, or when mounting the Counter facing downwards or sideways, it is suggested that the Counter be directly soldered to a PCB instead of using sockets. To Conform to EN/IEC Standards No-voltage input: 3 VDC Since the Counter is not flux-tight, do not use flux when soldering. Input terminals have no insulation from power supply terminals. The power supply terminals must be supplied from a SELV source in accordance with IEC61010-1 Annex H. SELV (separated extra-low voltage) source is a power supply having double or reinforced insulation between the primary and the secondary circuit and having output voltage of 30 V rms max. and 42.4 V peak max. or 60 VDC max. Avoid automatic and dip soldering. Manually solder the Counter onto a PC board, and avoid cleaning as much as possible. Cleaning When mounting the Counter on a PC board with components which consume higher current than the H7E@-N@P, observe the following precautions. To prevent damage, the exterior of the Counter must not be exposed to organic solvents (3.g. paint thinner or benzine), strong alkalis, or strong acids. 1. Minimize the wiring (less than 50 mm) from the H7E@-N@P to the power supply section. 2. Avoid placing the H7E@-N@P power, timer, counter, or reset input circuit in parallel with circuits that consume large currents, particularly on the positive side. Others General Information The terminals are solder-plated. Finish soldering the terminals within 5 seconds, at a solder iron tip temperature of 250°C ± 10°. • No user-serviceable parts. • Return to OMRON for all repairs. ALL DIMENSIONS SHOWN ARE IN MILLIMETERS. To convert millimeters into inches, multiply by 0.03937. To convert grams into ounces, multiply by 0.03527. Cat. No. M064-E1-03 C-40 In the interest of product improvement, specifications are subject to change without notice. Self-powered Totalizer New H7E (Common)
H7ECNV 价格&库存

很抱歉,暂时无法提供与“H7ECNV”相匹配的价格&库存,您可以联系我们找货

免费人工找货