H7ETNV1B

H7ETNV1B

  • 厂商:

    OMRON(欧姆龙)

  • 封装:

  • 描述:

    Self-Powered Time Counter, Subminiature Time Counters With Enhanced Appearance And Features

  • 数据手册
  • 价格&库存
H7ETNV1B 数据手册
R Self-Powered Time Counter H7ET Subminiature Time Counters With Enhanced Appearance and Features Large display with 8.6 mm (0.338 in) height Available with backlit LCD PNP/NPN DC voltage input available Seven digits, time range 0 to 3999d23.9h Key-protect switch to prevent front resetting Selectable time range: 999999.9h or 3999d23.9h and 999h59m59s or 9999h59.9m H NEMA 4/IP66 front H Replaceable battery H New black case H H H H H H Ordering Information J TIME COUNTERS Time range Count input p Display p y 999999.9h or 3999d23.9h (selectable) 999h59m59s or 9999h59.9m (selectable) PNP/NPN universal DC voltage g input p 7-segment LCD with backlight H7ET-NV-BH H7ET-NV1-BH 7-segment LCD H7ET-NV-B H7ET-NV1-B AC/DC multi-voltage input 7-segment LCD H7ET-NFV-B H7ET-NFV1-B No-voltage input 7-segment LCD H7ET-N-B H7ET-N1-B J MODEL NUMBER LEGEND H7ET - N 1 2 3 4 1. Count Input None: No-voltage input V: PNP/NPN universal DC voltage input FV: AC/DC multi-voltage input 3. Case Color B: Black 2. Time Range None: 999999.9h/3999d23.9h 1: 999h59m59s/9999h59.9m 4. Display None: 7-segment LCD without backlight H: 7-segment LCD with backlight J ACCESSORIES (ORDER SEPARATELY) Item Part number Replacement battery Y92S-36 Wire-wrap terminal (set of two terminals) Panel-mounting g adapter p Y92S-37 26 mm × 45 mm Y92F-75 24.8 mm × 48.8 mm Y92F-77B 1 H7ET H7ET Specifications J GENERAL Item H7ET-NV-B H7ET-NV-BH Operating mode UP type Mounting method Panel mounting External connections Screw terminals, optional wire-wrap terminals (See Note 3.) Reset External/Manual reset Display 7-segment LCD with or without backlight (character height: 8.6 mm) (See Note 1.) Number of digits 7 Time range 0.0h to 999999.9h or 0.0h to 3999d23.9h (switchable with switch) 0s to 999h59m59s or 0.0m to 9999h59.9m (switchable with switch) Count input PNP/NPN universal DC voltage input PNP/NPN universal DC voltage input Case color Black Attachment Waterproof gasket, panel-mounting bracket, time unit labels (See Note 2.) Approved standard UL508, CSA C22.2 No.14, Lloyds Conforms to EN61010-1/IEC61010-1 (pollution degree2/overvoltage category III) Conforms to VDE0106/P100 Note: H7ET-NFV-B AC/DC multi-voltage input H7ET-N-B No-voltage input H7ET-NV1-B H7ET-NV1-BH H7ET-NFV1-B AC/DC multi-voltage input H7ET-N1-B No-voltage input 1. Only PNP/NPN universal DC voltage input models (-H models) are available with a backlight. 2. “-hours,” “-d-h,” “-h-m,” and “-h-m-s” labels are included. 3. Wire-wrap terminals (Y92S--37) can be ordered separately. J RATINGS Item H7ET-NVj-B, H7ET-NVj-BH H7ET-NFVj-B Supply voltage Backlight model: 24 VDC (for backlight) No-backlight model: Not required (powered by battery) Not required (powered by battery) Count input High (logic) level: 4.5 to 30 VDC Low (logic) level: 0 to 2 VDC (Input impedance: Approx. 4.7 kΩ) High (logic) level: 24 to 240 VAC/ VDC, 50/60 Hz Low (logic) level: 0 to 2.4 VAC/ VDC, 50/60 Hz Reset input No voltage input Maximum short-circuit impedance: 10 kΩ max. Short-circuit residual voltage: 0.5 V max. Minimum open impedance: 750 kΩ min. Minimum pulse width 1s Reset system External reset and manual reset: minimum signal width of 20 ms Terminal screw tightening torque 0.98 N S m max. Ambient temperature Operating: --10°C to 55°C (14°F to 131°F) with no condensation or icing Storage: --25°C to 65°C (--13°F to 149°F) with no condensation or icing Ambient humidity Operating: 25% to 85% 2 H7ET-Nj-B No voltage input Maximum short-circuit impedance: 10 kΩ max. Short-circuit residual voltage: g 0.5 V max. Minimum open impedance: 750 kΩ min. H7ET H7ET J CHARACTERISTICS Item H7ET-NVj-j H7ET-NVj-Hj H7ET-NFVj-j H7ET-Nj-j Time accuracy ±100 ppm (25°C) Insulation resistance 100 MΩ min. (at 500 VDC) between current-carrying metal parts and exposed non-current-carrying metal parts, and between the backlight power supply and count input terminals/reset terminals for backlight models 100 MΩ min. (at 500 VDC) between current-carrying metal parts and exposed non-current-carrying metal parts and between count input terminals and reset terminals 100 MΩ min. (at 500 VDC) between current-carrying metal parts and exposed non-current-carrying metal parts Dielectric strength 1,000 VAC, 50/60 Hz for 1 min between current-carrying metal parts and exposed non-current-carrying metal parts and between the backlight power supply and count input terminals/reset terminals for backlight models 3,700 VAC, 50/60 Hz for 1 min between count input terminals and exposed non-current-carrying metal parts 2,200 VAC, 50/60 Hz for 1 min between reset terminals and exposed non-current-carrying metal parts and between count input terminals and reset terminals 1,000 VAC, 50/60 Hz for 1 min between current-carrying metal parts and exposed non-current-carrying metal parts Impulse withstand voltage 4.5 kV between current-carrying terminal and exposed non-current-carrying metal parts 4.5 kV between current-carrying terminal and exposed non-current-carrying metal parts 3 kV between input terminals and reset terminals 4.5 kV between current-carrying terminal and exposed non-current-carrying metal parts Noise immunity Between input terminals: ±600 V in normal mode, ±1.5 kV in command mode For backlight power supply (backlight model): ±480 V in normal mode, ±1.5 kV in command mode Between count input terminals: ±1.5 kV in normal mode, ±1.5 kV in command mode Between reset input terminals: ±500 V in normal mode, ±1.5 kV in command mode ±500 V in normal mode, ±1.5 kV in command mode Static immunity ±8 kV (malfunction) Vibration resistance Malfunction: 0.15-mm single amplitude at 10 to 55 Hz for 10 min each in 3 directions Destruction: 0.375-mm single amplitude at 10 to 55 Hz for 2 hrs each in 3 directions Shock resistance Malfunction: 200 m/s2 {approx. 20G} 3 times each in 6 directions Destruction: 300 m/s2 {approx. 30G} 3 times each in 6 directions Battery life 10 years min. with continuous input at 25°C (lithium battery) EMC (EMI) Emission Enclosure: (EMS) Immunity ESD: Enclosure rating Front panel: Terminal block: Weight (see note) Non-backlight model: Approx. 60 g Backlight model: Approx. 65 g Note: EN50081-1 EN55022 class B EN50082-2 EN61000-4-2: 4-kV contact discharge (level 2) 8-kV air discharge (level 3) Immunity RF-interference from AM Radio Waves: ENV50140: 10 V/m (80 MHz to 1 GHz) (level 3) Immunity RF-interference from Pulse-modulated Radio Waves: ENV50204: 20 V/m (900 MHz ± 5 MHz) (level 3) Immunity Conducted Disturbance: ENV50141: 10 V (0.15 to 80 MHz ) (level 3) Immunity Burst: EN61000-4-4: 2-kV power line (level 3) 2-kV I/O signal line (level 4) IP66, NEMA4 with waterproof packing IP20 Approx. 60 g Weight includes waterproof gasket and panel-mounting bracket. 3 Approx. 60 g H7ET H7ET Nomenclature J TIME COUNTER Front view Reset Key Reset the count value. Not operable under key-protect. Key-protect Switch Time-range switch If the switch setting is changed, press the Reset Key on the front panel. Setting (see note) Key-protect Front panel Setting (see note) OFF (default setting) Time range H7ET-Njj-jj H7ET-Njj1-jj 0.0h to 3999d23.9h (default setting) 0s to 999h59m59s (default setting) Bottom view Front panel ON Terminal block 0.0h to 999999.9h 0.0m to 9999h59.9m Terminal block Note: Perform switch setting before mounting to a control panel. Operation J OPERATING MODES H7ET Time Counter Incrementing Operation (Up) Reset Timer input Internal clock timer value Full-scale (Full-scale --0.1 (1)) Timer display values 4 H7ET H7ET Dimensions Unit: mm (inch) J H7ET-N 44.8 (1.76) Panel Cutout Separate mounting 60 min. 24 (0.94) 22 (0.87) 48 (1.89) 60 min. 48.5 (1.91) 45 +0.5 0 22.2 +0.5 0 Joint mounting Dimensions with Panel-Mounting Bracket (48 ¢Units - 2.5) +10 0 22.2 +0.5 0 44.8 Waterproofing is not possible for joint mounting 37 (1.46) 35 24 (1.38) Installation J TERMINAL ARRANGEMENT Bottom view: View of the Time Counter rotated horizontally 180° Backlight Model Non-backlight Model Backlight 24 VDC Timer input Reset input Timer input Reset input 5 • When mounting, insert the Counter into the cutout. Insert the adapter from the back and push in the Counter while making the gap between the front panel and the cutout panel as small as possible. Use screws to secure the Counter. If waterproofing is desired, insert the waterproof gasket. • When several Counters are installed, ensure that the ambient temperature will not exceed specifications. • The appropriate thickness of the panel is 1 to 5 mm. H7ET H7ET Connections J PNP/NPN UNIVERSAL DC VOLTAGE INPUT MODEL WITH BACKLIGHT 1. Contact Input (Input by a Relay or Switch Contact) Relay 2. Solid-state Input Open collector of a PNP transistor Relay Backlight 24 VDC Input or Switch Input Reset Backlight 24 VDC Open collector of a PNP transistor Reset or Switch or Open collector of an NPN transistor Note: 6 or Open collector of an NPN transistor 1. Terminals 2 and 4 (input circuit and reset circuit) are functionally isolated. 2. Select input transistors according to the following: Dielectric strength of the collector ≧ 50 V Leakage current < 1 µA H7ET H7ET J PNP/NPN UNIVERSAL DC VOLTAGE INPUT MODEL WITHOUT BACKLIGHT J NO-VOLTAGE INPUT MODEL 1. Contact Input (Input by a Relay or Switch Contact) Relay 1. Contact Input (Input by a Relay or Switch Contact) Relay Input Relay Reset Relay Reset or Switch or Switch or Switch 2. Solid-state Input Open collector of a PNP transistor Terminals 2 and 4 are internally connected. or Switch Note: Use Relays and Switches that have high contact reliability because the current flowing from terminals 1 or 3 is as small as approx. 10 µA. OMRON’s G3TA-IA/ID is recommended as the SSR. Open collector of a PNP transistor Input Input Reset 2. Solid-state Input (Open Collector Input of an NPN Transistor) Open collector of an NPN transistor Input or Open collector of an NPN transistor Reset Open collector of an NPN transistor or Open collector of an NPN transistor Terminals 2 and 4 are internally connected. or Switch Note: 1. Residual voltage in the output section of Proximity Sensors or Photoelectric Sensors becomes less than 0.5 V because the current flowing from terminals 1 or 3 is as small as approx. 10 µA, allowing easy connection. 2. Select input transistors according to the following: Dielectric strength of the collector ≧ 50 V Leakage current < 1 µA Note: 1. Terminals 2 and 4 (input circuit and reset circuit) are functionally isolated. 2. Select input transistors according to the following: Dielectric strength of the collector ≧ 50 V Leakage current < 1 µA J AC/DC MULTI-VOLTAGE INPUT MODEL Relay Input or Switch Reset Relay or Switch or Open collector of an NPN transistor 7 H7ET H7ET Accessories (Order Separately) An H7ET is supplied with a mounting bracket and nut. In addition, the panel-mounting adapters shown here allow the H7ET to be fitted to existing panel cutouts. J Y92F-75 PANEL-MOUNTING ADAPTER FOR 26 ¢ 45 RECTANGULAR CUTOUT Must be used with mounting bracket supplied with the Counter Panel cutout Two 3.5 dia. mounting holes Two M3 31 24.2 22.2 (1.22) 26 (1.02) 26 4 45.2 48.2 63 72 (2.83) 45 63 (2.48) J Y92F-77B PANEL-MOUNTING ADAPTER FOR 24.8 ¢ 48.8 RECTANGULAR CUTOUT Must be used with mounting bracket supplied with the Counter Panel cutout 28.8 24.2 22.2 (1.13) 24.8 (0.98) 45.2 48.2 53.8 (2.12) 48.8 (1.92) 4 Y92S-37 Wire-Wrap Terminal (Set of Two Terminals) 44.8 (1.76) Wire-wrap terminal (1 × 1 mm) 24 (0.94) 22 48 (1.89) The wire-wrap terminals have a cross sectional dimension of 1x1 mm. Select one of three guages of wire from the table at right. Also listed in the table is the appropriate wiring hardware. 2 Wire 8 48.5 5 65.6 (2.58) Bit Sleeve 17.1 Wrapped state AWG22 2-A 2-B Normal AWG24 1-A 1-B Normal AWG26 1-B 1-B Normal H7ET H7ET J Y92S-36 REPLACEMENT (LITHIUM) BATTERY (3 V) 24.5 dia. 7.7 Precautions ! WARNING J BEFORE USE This product has a built-in lithium battery. Do not short-circuit the + and -- terminals, charge, disassemble, deform, or expose the battery to fire. The battery may explode (break), catch fire, or cause liquid leakage. An insulation sheet has been inserted to maintain the quality of the Totalizer in the event of a long period without use. Be sure to remove this sheet before attempting to use the product. Remove the insulation sheet and press the Reset Key on the front panel of the Counter. (With the H7ET-N,-NV(-H),-NV1(-H), models, “0” or “0.0” will be displayed after 1 s.) ! Caution Do not use any battery other than the specified one (Y92S-36). Using another battery may cause liquid leakage or breakage, resulting in malfunction or injury. Insulation Sheet ! Caution If a voltage other than the rated one is applied, internal elements may be damaged. Do not use the Counter in the following places: • • • Reset Key Locations subject to direct sunlight. Switch settings on the Counter must be performed before mounting it to a control panel. Locations subject to corrosive gases. Locations subject to dust. Do not use the Counter in locations subject to: SSevere changes in temperature. SCondensation as the result of high temperatures. J MOUNTING PRECAUTIONS FOR PANEL- MOUNTING Although the operating section is watertight (conforming to NEMA 4, IP66), a rubber gasket is provided to avoid water leakage through the gap between the Counter and panel cutout. Unless this rubber gasket is tightly squeezed on, water may permeate inside the panel. For this reason, be sure to tighten the screws for fixing the panel-mounting bracket. Screw for the Panel-Mounting Bracket The wider side must face the panel. Panel 9 Adapter Adapter screw section 0.5 to 1 mm Tighten the screw until the distance is within the range shown above. H7ET H7ET J INPUT AND POWER SUPPLY The H7ET operates using a Battery. If the H7ET is connected to a device that has +V and OUT terminals that are connected with a diode as shown in the circuit diagram, the circuit indicated by the arrow 1 or 2 will be formed when the device is turned OFF. As a result, the H7ET may be reset or count by one. Such devices should not be connected to the H7ER. Do not apply voltage on the Counter if the Counter is a model that operates with no-voltage input, or the internal circuit of the Counter may be damaged. Do not connect any single input signal in parallel to Counter models operating with no-voltage input and those operating with voltage input, to avoid malfunction. Internal circuit J RESET INPUT AND COUNT INPUT When connecting a sensor to the Counter that operates with no-voltage input, make sure that the sensor has open collector output. Count input or reset input Sensor If an excessive voltage is applied to the count or reset input terminals, the internal elements may be damaged. Ensure that the following voltages are not exceeded: SPNP/NPN universal voltage input model: 30 VDC SAC/DC voltage input model: At count input: 240 VAC (peak voltage: 338V) 240 VDC At reset input: 3 VDC (no-voltage input) No-voltage input model: 3 VDC The operation of the Counter may be affected if the line voltage of the power supply exceeds 500 pF (about 10 m, with parallel wires of 2 x 2 mm). Keep all wires as short as possible. When using shielded wire, stray capacitance may occur. Do not remove the outer case when voltage is being applied to the power supply terminals or to the input terminals. When connecting an open collector input from a transistor to the Counter that operates with no-voltage input, make sure that the leakage current of the transistor is 5 µA maximum. The input for the H7Ej-NFV-j is a high-impedance circuit so influence from an induced voltage may result in malfunction. When the input signal wiring is longer than 10 m (stray capacitance of 120 pF/m, at room temperature), a CR filter or a bleeder resistor should be connected. When connecting count input from an SSR to the Counter that operates with AC/DC voltage input, use OMRON’s G3TA-IA or G3TA-ID SSR. Otherwise, make sure that the leakage current of the SSR is 0.1 mA maximum or connect a bleeder resistor in parallel to the input circuit of the Counter. or J COUNT INPUT OR RESET INPUT TO MORE THAN ONE H7ET COUNTER AT A TIME Leakage current: 0.1 mA max. or or PNP/NPN Universal DC Voltage Input *Bleeder resistor The voltage between terminals 1 and 2 must be 1.5 V maximum when the SSR is OFF. J BACKLIGHT POWER SUPPLY or To reduce variation in the brightness of the backlight when using more than one H7ET with a backlight, use the same power supply for all the backlights. or Note: H (Reset ON) level must be 4.5 V minimum. 4.7 (kΩ)/N + V H= 4.7 (kΩ)/N + R When connecting the DC power supply for the backlights, be sure to connect the polarities correctly. No-voltage Input J INPUT VERIFICATION WITH THE H7ET TIME COUNTER or The decimal point of the LCD blinks every other second while an input signal is being applied. If the decimal point is not blinking, the input signal is not being received correctly. Check the input signal connections. Note: 1. The leakage current of the transistor used for input must be less than 1 µA. 2. The forward voltage of the diode must be as low as possible (i.e., 0.1 V maximum with an IF of 20 µA) so the voltage between terminals 3 and 4 will be 0.5 V when the reset input is ON. 10 H7ET H7ET J UNIT LABEL FOR TIME COUNTER AND TACHOMETER J EN/IEC STANDARDS The counter input, reset input, and backlight power supply terminals of the no-voltage input or PNP/NPN universal DC voltage input models (H7Ej-N,-N1, H7Ej-NV(-H),-NV1(-H)) are not isolated. A unit label has been packed with the Counter. Use in accordance with the application. A SELV power supply conforming to Appendix H of IEC61010-1 should be used for the counter input, reset input and backlight power supply terminals. A SELV power supply is a power supply for which the input and output have double or reinforced insulation, and for which the output voltage is 30 Vrems with 42.4 V peak or 60 VDC max. (Only the H7Ej-NVj-H has a backlight.) J BATTERY REPLACEMENT The terminals for counter input and reset input for AC/DC multi-voltage input models have basic insulation. Remove the wiring when replacing the Battery. Do not come in contact with any item to which high voltage is being applied. Doing so may result in electric shock. Connect the reset input terminals to a device that does not have exposed current-carrying parts and has basic insulation for 240 VAC. Before changing the Battery, be sure that you are not carrying any static electric charge. Procedure for replacing the Battery (refer to the diagrams below): 1. Using the tool, pry open the lift-tab on the case. (1) 2. Pull the body out of its outer case. (2) 3. Lift the Battery up by the edge and remove it. (3) When removing the Battery, do not come in contact with the display area or any internal parts. 4. Wipe the back of the new Battery before inserting it. 5. Ensure that the + and -- terminals are correctly oriented. 6. After replacing the Battery, re-insert the body into its case. (4) Check that the case is securely held in by the lift-tab. 7. Press the Reset Key before use (not necessary for H7ET-N,-NV,-NV1). (5) When the internal Battery nears expiration, the display may flicker. (1) (2) Tool (1) (3) (4) (5) 11 H7ET H7ET NOTE: DIMENSIONS SHOWN ARE IN MILLIMETERS. To convert millimeters to inches divide by 25.4. R OMRON ELECTRONICS LLC OMRON ON--LINE OMRON CANADA, INC. 1-800-55-OMRON Global -- http://www.omron.com USA -- http://www.omron.com/oei Canada -- http://www.omron.com/oci 416-286-6465 One East Commerce Drive Schaumburg, IL 60173 Cat. No. GC TMCN1 3/02 Specifications subject to change without notice. 12 885 Milner Avenue Scarborough, Ontario M1B 5V8 Printed in U.S.A.
H7ETNV1B 价格&库存

很抱歉,暂时无法提供与“H7ETNV1B”相匹配的价格&库存,您可以联系我们找货

免费人工找货