JUSP-NS500
PROFIBUS-DP unit
PROFIBUS-DP connectivity with positioning
functionality.
• Connects directly to the Sigma-II series drive
• Simplifies distributed control and information
management
• No programming languages are required.
• Various positioning functions including point-topoint mode (with multi-step speed positioning available) and station number mode (indexing function)
• All parameters are set and maintained by a
PLC or PC.
• Up to 126 servos can be connected to the
PROFIBUS-DP network
System configuration
Cable connection
Sigma-II
series
Servo Drive
SERVOPACK
SGDH200V
Ver.
CJ1 series
PROFIBUS-DP
master
CHARGE
POWER
JUSP-NS500
PROFIBUS-DP
NS500
6
CN3
(CN11) Computer connecting cable
(CN10)
CN1
(CN6) PROFIBUS-DP network
(CN4) External I/O or fully-closed encoder signal
CN2
PROFIBUS-DP
SERVOPACK
SGDH200V
Ver.
CHARGE
POWER
CN3
Sigma-II
series
Servo Drive
NS500
6
JUSP-NS500
PROFIBUS-DP
unit
CN1
Limit switches
contact sensors
CN2
SERVOPACK
NS500
SERVOPACK
SGDH-
SERVOPACK
NS500
CHARGE
POWER
6
CHARGE
POWER
200V
Ver.
200V
Ver.
6
CHARGE
POWER
CN3
CN3
CN3
CN1
CN1
CN1
CN2
CN2
NS500
SGDH-
SGDH200V
Ver.
CN2
6
Sigma-II series
Linear Motor
Sigma-II series
Servo Motor
PROFIBUS-DP unit
105
Y203-EN2-02-Katalog.book Seite 106 Mittwoch, 24. Mai 2006 2:22 14
Specifications
JUSP-NS500
- PROFIBUS-DP interface unit
Item
Type
Applicable servo drive
Installation method
Basic
specifications
PROFIBUS-DP
communications
Command format
Position control
functions
Input signals
Output signals
Internal functions
Details
JUSP-NS500
All SGDH-@@@E models
Mounted on the SGDH servo drive side: CN10.
Power supply method
Supplied from the servo drive control power supply.
Power consumption
1.3 W
Baud rate setting
The baud rate is automatically set by the master between 9.6 kbps and 12 Mbps.
Station address setting
Select the address from 0 to 7D (0 to 125) using the rotary switches.
Operation specifications
Positioning using PROFIBUS-DP communications
Reference input
PROFIBUS-DP communications
Commands: motion commands (position, speed), parameter read/write
Acceleration/deceleration method
Linear first/second-step, asymmetric, exponential, S-curve
Fully-closed control
Possible
Fixed allocation to SERVOPACK CN1 Forward/reverse run prohibited, zero point return deceleration LS, zero point signal,
connector
external positioning signal
NS500 unit
Emergency stop signal
Servo alarm, brake interlock, servo ready, positioning completion
Servo drive CN1 connector∗
NS500 unit
P1, P2 (area signals)
Position data latch function
Position data latching is possible using phase C, zero point signals, and external signals.
Protection
Parameters damage, parameter setting errors, communications errors, etc.
LED indicators
ERR:
Module error
COMM: Communications status
Note: *The allocation of the output signals for brake interlock, servo ready, or positioning completion can be changed using parameter settings.
Transmission specifications
Item
Communication format
Transmission speed (kbps)
Transmission distance (m)
Transmission media
Number of stations
Specifications
Conforms to PROFIBUS-DP
9.6
19.2
93.75
187.5
1200
1000
STP cable
32 stations (can be extended to 126 stations using repeater.)
500
400
1500
200
12000
100
Cable
Item
Cable type impedance
Capacity
Loop resistance
Wire gage
Conductor area
Specifications
Shielded twisted-pair wire type A 135 to 165 Ω
< 30 pf/m
110 Ω/km
0.64 mm
> 0.34 mm2
Connector
9-pin D-sub connectors are used.
106
Motion controllers
Y203-EN2-02-Katalog.book Seite 107 Mittwoch, 24. Mai 2006 2:22 14
Nomenclature
Ground wire
Connected to ground on the servo drive
Rotary switch (x1, x10)
For node address setting
RS-232C connector (CN11)
For setup tool
LED (COMM)
Communication status LED for PROFIBUS-DP
LED (ERR)
Module error status LED
Connector for PROFIBUS-DP communication (CN6)
Connector for external signals (CN4)
For connecting external I/O signals or fully-closed
encoder signals
Dimensions
JUSP-NS500 - PROFIBUS-DP interface unit
Units: mm
Approx. weight: 0.2 kg
(24)
(100)
FG terminal
M4
Connector
to SERVOPACK
6
8
5
7
NS500
0 1
2
4
8
9
9
0 1
2
5
6
7
3
CN11
X
10
X
1
3
4
D
R
C
N
11
142
CN6
Name
plate
CN4
20
PROFIBUS-DP unit
133
107
Y203-EN2-02-Katalog.book Seite 108 Mittwoch, 24. Mai 2006 2:22 14
Installation
Standard connections
Servo drive
type SGDH
(For servo drive connection,
see Sigma-II chapter)
PXD/TXD-P
PXD/TXD-N
VP
DGND
PROFIBUS-DP
communication
3
8
6
5
CN 6
PROFIBUS-DP I/F Unit
Type JUSP-NS500
Fully-closed encoder
for speed/position
detection
CN 4
1, 2, 3
16
17
18
19
14
15
PG0V
PA
/PA
PB
/PB
PC
/PC
+ 24VIN
CN 4 3.3 kΩ
24 VDC
50mA or more
NS500 Side
PG
E-STOP
External
power supply
DC 5 to 12 V
P1 + 12
P
P1 13
P2 + 10
P
P2 20
Backup battery*1
2.8 to 4.5 V
+
-
BAT (+)
P
BAT (-)
+24VIN
+
Not Used
+24 V
Zero point return
deceleration LS
with /DEC ON
Forward run prohibit
with P-OT OFF
21
0V
CN 1
37
22
47
38
39
1
-
Reverse run prohibit
with N-OT OFF
External positioning
signal
41
P-OT
42
N-OT
43
25
26
27
28
WXT
29
44
30
Not Used
45
31
32
Not Used
P represents twisted-pair wires.
46
represents shield.
AL 02
3.3 kΩ
40
/DEC
AL 01
FG
Alarm code output
Maximum operating voltage 30 VDC
Maximum output current 20 mADC
AL 03
SG
/COIN +
Positioning completed
(ON when positioning is completed)
/COIN /BK +
BK output*2
(ON when brake is released)
/BK /NEAR +
/NEAR ALM +
ALM -
Positioning near output
(ON when near)
Servo alarm output
(OFF with an alarm)
Photocoupler output
Maximum operating voltage 30 VDC
Maximum output current 50 mADC
Connect shield to connector shell.
*1 Connect when using an absolute encoder and when the battery is not connected to CN8.
*2 Set the signal assignment with the user constants.
Note: Connect the ground cable of the field bus I/F unit to the ground connector of the servo drive.
108
Motion controllers
Y203-EN2-02-Katalog.book Seite 109 Mittwoch, 24. Mai 2006 2:22 14
Ordering information
System configuration
Sigma-II series
Servo Drive
JUSP-NS500
PROFIBUS-DP unit
SERVOPACK
NS500
SGDH200V
Ver.
(CN10)
CHARGE
POWER
(CN11)
Computer connecting cable
(CN6)
PROFIBUS-DP Network
(CN4)
External I/O or fully-closed encoder signal
NS
Tool
Personal
computer
6
CN3
CN1
CN2
Sigma-II series
Servo motor
PROFIBUS-DP interface unit
Name
PROFIBUS_DP interface unit with point-to-point
positioning functionality
Model
JUSP-NS500
Serial cable (for CN11)
Name
Computer connecting cable
2m
Model
R88A-CCW002P4
Connectors
Name
Connector for CN4. For connecting external I/O signals or fully-closed encoder signals
Model
R88A-CNU01R or
DE9406973
Computer software
Name
NS tool
GSD file
Model
MOTION TOOLS CD
Servo system
Note: Refer to the servo systems section for more information
PROFIBUS-DP unit
109
Y203-EN2-02-Katalog.book Seite 110 Mittwoch, 24. Mai 2006 2:22 14
ALL DIMENSIONS SHOWN ARE IN MILLIMETERS.
To convert millimeters into inches, multiply by 0.03937. To convert grams into ounces, multiply by 0.03527.
Cat. No. I12E-EN-02
110
In the interest of product improvement, specifications are subject to change without notice.
Motion controllers