LY4-AC12

LY4-AC12

  • 厂商:

    OMRON(欧姆龙)

  • 封装:

    -

  • 描述:

    RELAY GEN PURPOSE 4PDT 10A 12V

  • 详情介绍
  • 数据手册
  • 价格&库存
LY4-AC12 数据手册
Bi-power Relays LY CSM_LY_DS_E_4_9 Power-switching Compact General-purpose Relays • The standard models include models that are compliant with the UL, CSA, and SEV safety standards and with the Electrical Appliances and Material Safety Act. • Equipped with an arc barrier for arc interruption. • Withstand voltages up to 2,000 V. • New built-in diode and built-in CR circuit models have joined the series. • The lineup also includes models that are compliant with the LR and VDE safety standards. • Single-pole and double-pole models have AC4 ratings and DC2 ratings (operating coil ratings: 100/110 VAC, 110/120 VAC, 200/220 VAC, 220/240 VAC, and 100/ 110 VDC). • Three-pole and four-pole models have AC4 ratings and DC2 ratings (operating coil ratings: 100/110 VAC, 200/220 VAC and 100/110 VDC). Refer to the standards certifications and compliance section of your OMRON website for the latest information on certified models. Refer to the Common Relay Precautions. Model Number Structure Relays with Plug-in Terminals Relays with PCB Terminals Case-surface mounting Structure Classification Number of poles *LY1 **LY1N *LY1-0 *LY1F *LY2 **LY2N *LY2-0 *LY2F **LY2Z **LY2ZN **LY2Z-0 **LY2ZF 3 *LY3 **LY3N *LY3-0 *LY3F 4 *LY4 **LY4N *LY4-0 *LY4F 1 **LY1-D **LY1N-D2 --- --- **LY2-D **LY2N-D2 --- --- **LY2Z-D **LY2ZN-D2 --- --- 3 **LY3-D **LY3N-D2 --- --- 4 **LY4-D **LY4N-D2 --- --- 1 --- --- **LY2-CR **LY2N-CR **LY2Z-CR **LY2ZN-CR 1 Standard models Compliance with Electrical Appliances and Material Safety Act Models with diode for coil surge absorption (DC coil specification only) Models with CR circuits for coil surge absorption (AC coil specification only) With operation indicators 2 2 2 Bifurcated Bifurcated Bifurcated Note: 1. Cells with a diagonal line cannot be manufactured. Ask your OMRON representative for details on manufacturing products for cells containing “---” in the above table. 2. If #187 tab terminals are required, use the LY1F-T2 or LY2F-T2 (single-pole or double-pole models only). 3. Refer to page 17 for information on plug-in terminal and socket combinations. 4. Items with an asterisk (*) in the table are certified for UL, CSA, and SEV. This is indicated with a certification mark on the products. 5. Items with two asterisks (**) in the table are certified for UL and CSA. This is indicated with a certification mark on the products. 6. All models in the table are certified for IEC (TÜV). 7. The models with plug-in terminals (single-pole, double-pole, and 4-pole) were combined with the PTF-E for the EC Declaration of Conformity. These products display the CE Marking. 1 LY Ordering Information When your order, specify the rated voltage. Relays Models with Plug-in Terminals Number of poles Classification Model Standard models Models with built-in operation indicators Models with single Models with built-in contacts diodes Models with built-in diodes and operation indicators LY1 LY1N LY1-D 1 pole Rated voltage (V) 12, 24, 100/110, 110/120, or 200/220 VAC 12, 24, 48, or 100/110 VDC 12, 24, 100/110, 110/120, or 200/220 VAC 12, 24, or 100/110 VDC 12, 24, 48, or 100/110 VDC Model LY2 LY2N LY2-D LY1ND2 12, 24, or 48 VDC LY2N-D2 Models with built-in CR circuits --- --- LY2-CR Models with built-in CR circuits and operation indicators --- --- LY2N-CR --- --- Standard models Models with built-in operation indicators Bifurcated contacts Models with built-in diodes Models with built-in diodes and operation indicators Models with built-in CR circuits Models with built-in CR circuits and operation indicators LY2Z 2 poles Rated voltage (V) 12, 24, 100/110,110/ 120, 200/220, or220/240 VAC 12, 24, 48, or 100/110 VDC 12, 24, 100/110,110/ 120, 200/220, or 220/240 VAC 12, 24, 48, or 100/110 VDC 12, 24, 48, or 100/110 VDC Model LY3 3 poles Rated voltage (V) 12, 24, 100/110, or 200/220 VAC Model LY4 12, 24, 48, or 100/110 VDC LY3N LY3-D 12, 24, 48, or 100/110 VDC LY3ND2 100/110, 110/120, 200/220, or 220/240 VAC 100/110, 110/120, 200/220, or 220/240 VAC 100/110 or200/220 VAC 12, 24, 48, or 100/ 110 VDC 100/110, 110/120, 200/220, or 220/240 VAC 12 or 24 VDC 12, 24, 100/110, or 200/220 VAC 12, 24, 48, or 100/110 VDC 12, 24, 48, or 100/110 VDC 12, 24, or 100/110 VDC 4 poles Rated voltage (V) 12, 24, 100/110, or 200/220 VAC 12, 24, 48, or 100/110 VDC LY4N LY4-D LY4ND2 12, 24, 100/110, or 200/220 VAC 12, 24, 48, or 100/110 VDC 12, 24, 48, or 100/110 VDC 12, 24, 48, or 100/110 VDC --- --- --- --- --- --- --- --- --- --- --- --- --- --- --- --- --- --- --- --- --- --- --- --- --- --- --- --- --- --- --- --- LY2Z-D 12, 24, or 48 VDC --- --- --- --- --- --- LY2ZND2 12, 24, or 100/110 VDC --- --- --- --- --- --- LY2Z-CR 100/110 VAC --- --- --- --- --- --- LY2ZNCR 100, 110, 110/1 20, or 200/220 VAC --- --- --- --- LY2ZN Relays with PCB Terminals Number of poles Classification Model Models with single contacts LY1-0 1 pole Rated voltage (V) 24,100/110, 110/120, or 200/220 VAC Model LY2-0 12 or 24 VDC Bifurcated contacts --- --- LY2Z-0 2 poles Rated voltage (V) 12, 24, 100/110, 110/120, 200/ 220, or 220/240 VAC 12, 24, 48 or 100/110 VDC 100/110 VAC 24, 48, or 100/110 VDC Model LY3-0 3 poles Rated voltage (V) 24, 100/110, or 200/220 VAC Model LY4-0 12, 24, 48, or 100/110 VDC 4 poles Rated voltage (V) 24, 100/110, or 200/ 220 VAC 12, 24, 48, or 100/110 VDC --- --- --- --- Model 3 poles Rated voltage (V) Model --- Case-surface Mounting Number of poles Classification Models with single contacts Bifurcated contacts Model LY1F --- 1 pole Rated voltage (V) 24, 100/110, 110/120, 200/220, or 220/240 VAC 6, 12, 24, or 100/110 VDC --- Model LY2F LY2ZF 2 poles Rated voltage (V) 12, 24, 100/110, 110/ 120, 200/220, or 220/240 VAC 12, 24, 48, or 100/110 VDC 24, 100/110, or 200/220 VAC LY3F 12, 24, 100/110, or 200/220 VAC LY4F --- 12, 24, 100/110, or 200/220 VAC 12, 24, or 100/110 VDC 12, 24, or 100/110 VDC --- 4 poles Rated voltage (V) --- --- 12 or 24 VDC 2 LY Accessories (Order Separately) Connection Sockets Connecting method Mounting method Number of poles Model PTF-08-PU PTF-08-PU-L 1 or 2 Front-mounting Sockets (PTF-@-PU, PTF@A) Track or screw mounting PTF08A PTF08A-E *1 3 PTF11A PTF-14-PU-L 4 PTF14A PTF14A-E *1 Solder terminals Back-mounting Sockets (PT@) Wrapping terminals Relays with PCB Terminals 1 or 2 PT08 *2 3 PT11 *2 4 PT14 *2 1 or 2 PT08QN 3 PT11QN 4 PT14QN 1 or 2 PT08-0 3 PT11-0 4 PT14-0 *1. The PTF@A-E Relays have finger protection. Round terminals cannot be used. Use forked terminals. *2. When ordering PT08, PT11, or PT14 sockets, please note that the minimum order quantity is 10 and orders are accepted in multiples of the minimum order. Relay Hold-down Clips Application Used with Socket mounting plate Used with Socket Item Approx. 3 For models with built-in CR circuits Approx. 2.5 Appearance Model Minimum order (quantity) * PYC-A1 PYC-P PYC-S Y92H-3 PYC-1 100 100 10 10 10 * Orders are accepted in multiples of the minimum order. Socket Mounting Plates Applicable sockets PT08 PT08QN PT11 PT11QN PT14 PT14QN Number of sockets Model 1 PYP-1 *1 18 PYP-18 *2 36 PYP-36 *2 1 PTP-1-3 12 PTP-12 1 PTP-1 10 PTP-10 *1. When ordering PYP-1, please note that the minimum order quantity is 10 and orders are accepted in multiples of the minimum order. *2. PYP-18 and PYP-36 can be cut to any required length. 3 LY Ratings and Specifications Ratings Standard Models with Built-in Operation Indicators Operating Coil, Single-pole and Double-pole Models Item Rated voltage (V) DC 50 Hz 60Hz Coil resistance (Ω) Coil inductance (H) Armature OFF Must-operate voltage (V) Armature ON 12 106.5 91 46 0.17 0.33 24 53.8 46 180 0.69 1.3 25.7 22 788 3.22 5.66 100/110 11.7/12.9 10/11 3,750 14.54 24.6 110/120 9.9/10.8 8.4/9.2 4,430 19.2 32.1 50 AC Rated current (mA) 200/220 6.2/6.8 5.3/5.8 12,950 54.75 94.07 220/240 4.8/5.3 4.2/4.6 18,790 83.5 136.4 0.33 6 150 40 0.16 12 75 160 0.73 1.37 24 36.9 650 3.2 5.72 18.5 2,600 10.6 21.0 9.1/10 11,000 45.6 86.2 Rated current (mA) Armature OFF 48 100/110 Must-release voltage (V) Maximum voltage (V) Power consumption (VA, W) Approx. 1.0 to 1.2 (at 60 Hz) 30% min.*2 110% of rated voltage 80% max.*1 10% min.*2 Approx. 0.9 to 1.1 (at 60 Hz) Approx. 0.9 3 poles Item AC DC Coil inductance (H) 50 Hz 60Hz Coil resistance (Ω) 12 159 134 24 0.12 0.21 24 80 67 100 0.44 0.79 100/110 14.1/16 12.4/13.7 2,300 10.5 18.5 200/220 9.0/10.0 7.7/8.5 8,650 34.8 59.5 Rated voltage (V) Must-operate voltage (V) Armature ON 12 112 107 0.45 0.98 24 58.6 410 1.89 3.87 48 28.2 1,700 8.53 13.9 12.7/13 8,500 29.6 54.3 Rated current (mA) Coil resistance (Ω) Armature OFF 100/110 Must-release voltage (V) Maximum voltage (V) 30% min.*2 110% of rated voltage 80% max.*1 10% min.*2 Power consumption (VA, W) Approx. 1.6 to 2.0 (at 60 Hz) Approx. 1.4 4 poles Item Rated voltage (V) AC DC Coil inductance (H) Must-operate voltage (V) Armature ON 50 Hz 60Hz 12 199 170 20 0.1 0.17 24 93.6 80 78 0.38 0.67 100/110 22.5/25.5 19/21.8 1,800 10.5 17.3 200/220 11.5/13.1 9.8/11.2 6,700 33.1 57.9 12 120 100 0.39 0.84 24 69 350 1.41 2.91 48 30 1,600 6.39 13.6 15/15.9 6,900 32.0 63.7 100/110 Must-release voltage (V) Maximum voltage (V) 30% min.*2 110% of rated voltage 80% max.*1 10% min.*2 Power consumption (VA, W) Approx. 1.95 to 2.5 (at 60 Hz) Approx. 1.5 Note: 1. The rated current and coil resistance are measured at a coil temperature of 23°C with tolerances of +15%/–20% for the AC rated current and ±15% for the DC coil resistance. 2. The AC coil resistance and inductance values are reference values only. (at 60 Hz). 3. Operating characteristics were measured at a coil temperature of 23°C. 4. The maximum voltage capacity was measured at an ambient temperature of 23°C. *1. There is variation between products, but actual values are 80% max. To ensure operation, apply at least 80% of the rated value (at a coil temperature of +23° C). *2. The actual values are 30% min. for AC and 10% min. for DC. To ensure release, use a value that is lower than the specified value. 4 LY Refer to List of Certified Models for a list of models that are certified for safety standards and the Electrical Appliances and Material Safety Act. Classification Item Load 1 pole Inductive load (cos φ = 0.4, L/R = 7 ms) Resistive load Contact type Contact materials 15 A at 110 VAC 15 A at 24 VDC Rated load Rated carry current Maximum contact voltage Maximum contact current 15 A Single Ag alloy 10 A at 110 VAC 10 A at 24 VDC 10 A at 110 VAC 7 A at 24 VDC 15 A 250 VAC 125 VDC 15 A 7.5 A at 110 VAC 5 A at 24 VDC 10 A 10 A Single-pole, double-pole models (models with built-in operation indicators, models with built-in diodes, and models with built-in CR circuits), 3-pole and 4-pole models Single-pole and double-pole models (standard models and bifurcated contact models) Ambient operating temperature Ambient operating humidity Bifurcated contacts Inductive load (cos φ = 0.4, L/R = 7 ms) Bifurcated Ag 5 A at 110 VAC 4 A at 110 VAC 5 A at 24 VDC 4 A at 24 VDC 7A 250 VAC 125 VDC 7A 7A Resistive load 10 A 250 VAC 125 VDC Type Item Double-, 3-, and 4-pole models Inductive load (cos φ = 0.4, L/R = 7 ms) Resistive load −25 to 55°C (with no icing or condensation)*1 −25 to +40°C (with no icing or condensation)*2 5% to 85% Note: 1. Some models in the LY1 and LY2 Series have an upper temperature limit of +40°C. This limitation is due to the diode junction temperature and the elements used. 2. Refer to Ambient Temperature vs. Coil Temperature Rise in Engineering Data on page 8 to 9 for information on operation in temperature conditions that are not described here. 3. When you apply a minimum of 10 A of current to an LY1 when it is used in combination with the PTF-08-PU, PTF-08-PU-L, PTF08A, PTF08A-E, or PT08, connect each of the following terminal pairs: (1) to (2), (3) to (4), and (5) to (6). *1. If the carry current is 4 A or less, the usable ambient temperature range is −25 to 70° C. *2. If the flowing current is 4 A or less, the usable ambient temperature range is -25 to 55° C. Characteristics Type Item *1 Contact resistance Operating time*2 Release time*2 Maximum Mechanical operating Rated load frequency Insulation resistance*3 Between coil and contacts Between contacts of Dielectric different polarity strength Between contacts of the same polarity Destruction Vibration resistance Malfunction Destruction Shock resistance Malfunction Mechanical Endurance Electrical*4 Failure rate P value (reference value)*5 Weight Standard models, models with built-in operation indicators, models with built-in CR circuits, and models with built-in diodes 50 mΩ max. 25 ms max. 25 ms max. 18,000 operations/h Bifurcated contacts Note: The values at the left are initial values. *1. Measurement conditions: 1 A at 5 VDC using the voltage drop method *2. Measurement conditions: With rated operating power applied, not including contact bounce. Ambient temperature condition: 23° C *3. Measurement conditions: For 500 VDC applied to the same location as for dielectric strength measurement. *4. Ambient temperature condition: 23° C *5. This value was measured at a switching frequency of 120 operations per minute. 1,800 operations/h 100 MΩ min. 2,000 VAC at 50/60 Hz for 1 min. 1,000 VAC at 50/60 Hz for 1 min. 10 to 55 to 10 Hz, 0.5-mm single amplitude (1.0-mm double amplitude) 10 to 55 to 10 Hz, 0.5-mm single amplitude (1.0-mm double amplitude) 1,000 m/s2 200 m/s2 AC: 50,000,000 operations min. (switching frequency: 18,000 DC: 100,000,000 operations min. operations/h) 1-, 3-, 4-pole: 200,000 operations min. 2-pole: 500,000 operations min. 2-pole: 500,000 operations min. (rated load, operating frequency: 1,800 (rated load, operating frequency: 1,800 operations/h) operations/h) 100 mA at 5 VDC 10mA at 5 VDC 1-pole and 2-pole: 40 g, 3-pole: Approx. 50 g, 4-pole: Approx. 70 g Endurance Under Real Loads (Reference Only) Item Load type AC motor AC lamp Capacitor (2,000 µF) AC solenoid LY1, 100 VAC LY2, 100 VAC Electrical life (×10,000 operations min.) Conditions 400 W, 100 VAC singlephase with 35-A inrush ON for 10 s, current, 7-A current OFF for 50 s flow 5 200 W, 100 VAC singlephase with 25-A inrush current, 5-A current flow ON for 10 s, OFF for 50 s 300 W, 100 VAC with 51-A inrush current, 3A current flow 10 300 W, 100 VAC with 51-A inrush current, 3A current flow ON for 5 s, OFF for 55 s Conditions 500 W, 100 VAC with 78-A inrush current, 5A current flow 24 VDC with 50-A inrush current, 1-A current flow 50 VA with 2.5-A inrush current, 0.25-A current flow 100 VA with 5-A inrush current, 0.5-A current flow Operating frequency ON for 5 s, OFF for 55 s 2.5 ON for 1 s, OFF for 6 s 10 150 ON for 1 s, OFF for 2 s 80 24 VDC with 50-A inrush current, 1-A current flow 24 VDC with 20-A inrush current, 1-A current flow 50 VA with 2.5-A inrush current, 0.25-A current flow 100 VA with 5-A inrush current, 0.5-A current flow Operating frequency LY4, 100 VAC Electrical life (×10,000 operations min.) 20 Conditions 200 W, 200 VAC threephase with 5-A inrush current, 1-A current flow 750 W, 200 VAC threephase with 18-A inrush current, 3.5-A current flow Operating frequency Electrical life (×10,000 operations min.) 50 ON for 10 s, OFF for 50 s 7 8 300 W, 100 VAC with 51-A inrush current, 3A current flow ON for 5 s, OFF for 55 s 5 1 24 VDC with 50-A inrush current, 1-A current flow ON for 1 s, OFF for 15 s 0.5 15 24 VDC with 20-A inrush current, 1-A current flow ON for 1 s, OFF for 2 s 20 100 50 VA with 2.5-A inrush current, 0.25-A current flow ON for 1 s, OFF for 15 s ON for 1 s, OFF for 2 s 50 100 VA with 5-A inrush current, 0.5-A current flow 100 ON for 1 s, OFF for 2 s 50 5 LY Details on Safety-standard-certified Models, LY@ • Standard models are certified for the UL, CSA, and SEV safety standards. • Refer to Model Number Structure on page 1 for a list of applicable models. • The rated values for safety standard certification are not the same as individually defined performance values. Always check the specifications before use. UL-certified Models (File No. E41643) Model Coil ratings Number of poles Contact ratings 15A, 120VAC (General use) 15A, 240VAC (General use) 15A, 30VDC (Resistive) 6 to 240VAC 6 to 125VDC 1 1/2HP, 120VAC 8.5FLA, 30LRA, 120VAC CSA-certified Models (File No. LR31928) Certified number of operations Model Coil ratings Number of poles 15A, 120VAC (General use) 100,000 operations 15A, 240VAC (General use) 6,000 operations 15A, 30VDC (Resistive) 6 to 240VAC 6 to 125VDC 100,000 operations 1 100,000 operations TV-5, 120VAC 25,000 operations 6,000 operations 470VA, Pilot duty, 120VAC 6,000 operations 15A, 120VAC (General use) 100,000 operations 15A, 120VAC (General use) 12A, 240VAC (General use) 7A, 250VAC (General use) 6,000 operations 100,000 operations 1/3HP, 240VAC 1,000 operations 5FLA, 50LRA, 50VDC TV-3, 120VAC 345VA, Pilot duty, 120-240VAC B300/R300 LY 6 to 240VAC 6 to 125VDC 2 1/2HP, 120VAC 100,000 operations 1/3HP, 240VAC 1,000 operations 8.5FLA, 30LRA, 120VAC 100,000 operations 5FLA, 50LRA, 50VDC 25,000 operations TV-3, 120VAC 345VA, Pilot duty, 120-240VAC 6,000 operations B300/R300 Pilot duty 10A, 240VAC (General use) (Same polarity) 10A, 30VDC (General use) (Same polarity) 6,000 operations 15A, 30VDC (Resistive) 5A, 38VDC (Resistive) 1/2HP, 120VAC 8.5FLA, 30LRA, 120VAC 3 4 6,000 operations 25,000 operations 5A, 38VDC (Resistive) 6 to 240VAC 6 to 125VDC 100,000 operations 470VA, Pilot duty, 120VAC 15A, 30VDC (Resistive) 2 Certified number of operations TV-5, 120VAC 7A, 250VAC (General use) LY 1/2HP, 120VAC 8.5FLA, 30LRA, 120VAC 12A, 240VAC (General use) 6 to 240VAC 6 to 125VDC Contact ratings 10A, 240VAC (General use) (Same polarity) 10A, 30VDC (Resistive) (Same polarity) 6,000 operations 2A, 40VDC (Resistive) (Same polarity) 6 to 240VAC 6 to 125VDC 1/2HP, 240VAC 1,000 operations 0.6A, 100VDC (Resistive) (Same polarity) 6,000 operations 3 4 100,000 operations 25,000 operations 6,000 operations 6,000 operations 1/8HP, 240VAC (Same polarity) 1/2HP, 240VAC (Same polarity) 1,000 operations 1/3HP, 240VAC (Same polarity) 2A, 40VDC (Resistive) 0.6A, 100VDC (Resistive) 6,000 operations TÜV-certified Models (File No. R50030064, EN 61810-1) Model Coil ratings Number of poles Contact ratings Certified number of operations 15 A, 110 VDC resistive load 10 A, 110 VAC inductive load 1 10 A, 250 VAC resistive load 7A, 250 VAC inductive load 10 A, 30 VDC resistive load 7 A, 30 VDC inductive load LY@ 10 A, 110 VAC resistive load 6 to 240 VAC 6 to 110 VDC 200,000 operations 7.5A, 110 VAC inductive load 2 7A, 250 VAC resistive load 4 A, 250 VAC inductive load 7 A, 30 VDC resistive load 4 A, 30 VDC inductive load 3 4 10 A, 110 VAC resistive load 7.5A, 110 VAC inductive load 100,000 operations 6 LY • When ordering a model that is certified for VDE or Lloyd’s Register (LR) standards, always specify “VDE-certified Model” or “LR Standard-certified Model” with your order. All standard models comply with the Electrical Appliances and Material Safety Act. VDE Certification (Certificate No. 6359, EN 61810-1) Model Coil ratings Number of poles Certified number of operations Contact ratings 10 A, 220 VAC resistive load 1 6, 12, 24, 50, 110, or 220 VAC 6, 12, 24, 48, or 110 VDC LY@-VD Model LY@ 7 A, 220 VAC inductive load 10 A, 28 VDC resistive load 7 A, 28 VDC inductive load Coil ratings 6 to 240 VAC 6 to 120 VDC Number of poles Contact ratings 1 15 A at 200 VAC 2 3 4 10A at 200 VAC 200,000 operations 7 A, 220 VAC resistive load 2 Compliance with Electrical Appliances and Material Safety Act, LY@ 4 A, 220 VAC inductive load 7 A, 28 VDC resistive load 4 A, 28 VDC inductive load LR-certified Models (File No. 00/10047) Model Number of poles Coil ratings 6 to 240 VAC 6 to 110 VDC LY@ Contact ratings 2 7.5 A, 230 VAC inductive load 4 5 A, 24 VDC inductive load Details on Safety-standard-certified Models, Sockets UL-certified Models (File No. E87929) Model Ratings Standard number PTF-08-PU 10A 250V PTF-14-PU 10A 250V (Same polarity) PTF08A(-E) PT08 15A 250V PTF11A PTF14A(-E) PT11 PT14 10A 250V UL508 Category Listed/Recognized SWIV2 Recognized CSA-certified Models (File No. LR31928) Model Ratings Standard number PTF-08-PU 10A 250V PTF-14-PU 10A 250V (Same polarity) PTF08A(-E) 15A 240V AC PTF11A PTF14A(-E) 10A 240V AC CSA C22.2 (No.14) Class number 3211 07 CE Marking Compliance Model PTF08A(-E) PTF14A(-E) Note: 1. 2. EMC Directive Low Voltage Directive Machinery Directive Not applicable ❍ Not applicable Safety Category 1 CE compliance is achieved when used with a relay (LY). The Safety Category refers to the maximum applicable category selected when constructing control system safety components. The category does not apply to individual components. TÜV Rheinland certification Model Ratings PTF-08-PU 10A 250V *1 PTF-14-PU 10A 250V *2 Standard number EN 61984 Certification number R50327595 *1. Ratings are for an ambient temperature of 55°C. At an ambient temperature of 70°C, the value is 7A. *2. Ratings are for an ambient temperature of 40°C. At an ambient temperature of 70°C, the value is 7A. 7 LY Engineering Data Engineering Data Maximum Switching Capacity 15 10 5 Life: 200,000 operations AC inductive load (cos φ = 0.4) 1 LY3 and LY4 AC resistive load 10 5 AC inductive load (cos φ = 0.4) 1 DC inductive load (L/R = 7 ms) Life: 500,000 operations Contact current (A) LY2 AC resistive load Contact current (A) Contact current (A) LY1 DC resistive load 0.1 0.1 50 DC inductive load (L/R = 7 ms) DC resistive load 0.1 10 AC inductive load (cos φ = 0.4) 0.5 DC resistive load 0 5 Life: 200,000 operations 5 1 DC inductive load (L/R = 7 ms) 0.5 0.5 AC resistive load 10 100 500 1,000 0 5 10 50 100 500 Contact voltage (V) 0 5 1,000 10 50 100 500 1,000 Contact voltage (V) Contact voltage (V) Endurance Curve AC resistive load 10 AC inductive load (cos φ = 0.4) 5 DC resistive load 1 0.5 DC inductive load (L/R = 7 ms) LY2 Number of operations (×104 operations) LY1 Number of operations (×104 operations) Contact current (A) LY2Z 1,000 110 VAC resistive load 500 24 VDC resistive load 100 50 1,000 24 VDC resistive load 500 110 VAC resistive load 100 50 110 VAC inductive load (cos φ = 0.4) 24 VDC inductive load (L/R = 7 ms) 0.1 Life: 500,000 operations 0 5 10 50 24 VDC 110 VAC inductive load inductive load (cos φ = 0.4) (L/R = 7 ms) 10 100 500 1,000 0 2 4 6 8 10 12 Contact voltage (V) 10 0 14 16 18 20 Switching current (A) 2 4 6 8 10 12 14 16 18 20 Switching current (A) Ambient Temperature vs. Mustoperate and Must-release Voltage 1,000 24 VDC resistive load 500 110 VAC resistive load 100 110 VAC inductive load (cos φ = 0.4) 50 LY2 100/110 VAC at 50Hz Must-operate/must-release voltage (%) LY2Z Number of operations (×104 operations) Number of operations (×104 operations) LY3 and LY4 1,000 24 VDC resistive load 110 VAC resistive load 110 VAC inductive load (cos φ = 0.4) 500 100 50 24 VDC inductive load (L/R = 7 ms) 24 VDC inductive load (L/R = 7 ms) 10 0 2 4 6 8 100 Number of Relays: 5 Must-operate voltage Must-release voltage (average value) 80 60 40 20 10 10 12 0 14 16 18 20 Switching current (A) 2 4 6 8 10 0 −40 −20 0 20 Switching current (A) 40 60 80 Ambient temperature (°C) Ambient Temperature vs. Coil Temperature Rise Must-operate voltage Must-release voltage Number of Relays: 5 (average value) 80 60 120 Rating: 100% applied 110 Rated power consumption: 1 W 100 90 80 70 60 50 40 LY1 100/110 VAC at 50Hz Maximum operating temperature (120° C) 15 A 10 A Coil temperature rise (°C) 100 LY1 24 VDC Coil temperature rise (°C) Must-operate/must-release voltage (%) LY2 24 VDC 120 90 80 70 50 40 40 No contact current 20 30 30 20 20 −40 −20 0 20 40 60 80 Ambient temperature (°C) 0 Maximum operating temperature (120° C) 15 A 10 A 7A 5A 3A No contact current 10 10 0 Rated power consumption: 1 VA 100 60 7A 5A 3A Rating: 100% applied 110 10 20 30 40 50 60 70 80 Ambient temperature (°C) 0 10 20 30 40 50 60 70 80 Ambient temperature (°C) 8 LY Rating: 100% applied Rated power consumption: 1 W 110 100 Maximum operating temperature (120° C) 90 80 10 A 70 120 Rating: 100% applied Rated power consumption: 1.0 VA 110 100 Maximum operating temperature (120° C) 90 80 70 10 A 7A 5A 3A 7A 50 50 5A 3A 40 40 100 90 Maximum operating temperature (120° C) 10 A 80 70 50 7A 5A 3A 40 20 10 10 20 30 40 LY3 100/110 VAC at 50Hz Rating: 100% applied Rated power consumption: 1.6 VA 100 10 A 90 10 10 20 30 40 50 60 70 80 Ambient temperature (°C) LY4 24 VDC 120 110 30 20 0 50 60 70 80 Ambient temperature (°C) Maximum operating temperature (120° C) 80 Coil temperature rise (°C) 10 No contact current Rating: 100% applied Rated power consumption: 1.5 W 110 100 7A 70 7A 60 5A 60 5A 50 3A 50 3A No contact current Maximum operating temperature (120° C) 10 A 80 70 40 90 70 60 50 40 No contact current 30 20 10 10 40 50 60 70 80 50 60 70 80 Ambient temperature (°C) Maximum operating temperature (120° C) 10 A 80 20 30 40 Rating: 100% applied Rated power consumption: 1.95 VA 110 30 20 30 100 20 10 20 120 30 0 10 LY4 100/110 VAC at 50Hz 120 90 0 Coil temperature rise (°C) 30 No contact current 0 Coil temperature rise (°C) Rating: 100% applied Rated power consumption: 1.4 VA 110 No contact current 20 40 120 60 60 60 30 LY3 24 VDC Coil temperature rise (°C) LY2 100/110 VAC at 50Hz 120 Coil temperature rise (°C) Coil temperature rise (°C) LY2 24 VDC 7A 5A 3A No contact current 10 10 0 20 30 40 Ambient temperature (°C) 50 60 70 80 Ambient temperature (°C) 0 10 20 30 40 50 60 70 80 Ambient temperature (°C) Models with built-in diodes The diode absorbs surge from the coil. With Diode Without Diode ON OFF ON OFF 140 V A 24 VDC Di To digital memory A 24 VDC A’ To digital memory A’ Note: 1. Make sure that the polarity is correct. 2. The release time will increase, but the 25-ms specification for standard models is satisfied. 3. Diode characteristics: Reversed dielectric strength: 1,000 V Forward current: 1 A Models with Built-in CR Circuits With CR Without CR 282 V 2.5 msec ms 282 V 80 V 9.4 ms 4.12 ms 600 V A 200 AC C = 0.033 μF R = 120 Ω A’ 200 AC A To digital memory scope A’ 9 LY Malfunctioning Shock LY2 100/110 VAC Y 560 N = 20 Measurement: Shock was applied 2 times each in 6 directions along 3 axes with the Relay energized and not energized to check the shock values that cause the Relay to malfunction. Criteria: Non-energized: 200 m/s2 , Energized: 200 m/s2 Energized Not energized 440 X 720 500 520 Z 370 Shock direction 350 450 520 700 Z' X X' X' Y Z 500 Y' Unit: m/s2 600 Z' Y' Dimensions (Unit: mm) Relays Solder terminals LY1 LY1N LY1-D LY1N-D2 Terminal Arrangement/Internal Connections (Bottom View) LY1 LY1N-D 0.5 Eight, 2-dia. holes 28 max. (The coil has no polarity.) 5 36 max. (Check the coil polarity when wiring and wire all connections correctly.) 21.5 max. 3 6.4 LY1N DC Models Note: 1. For the DC models, check the coil polarity when wiring and wire all connections correctly. 2. The indicator is red for AC and green for DC. 3. The operation indicator indicates the energization of the coil and does not represent contact operation. LY2 LY2Z LY2N LY2ZN LY2-D LY2Z-D LY2N-D2 LY2ZN-D2 LY1N-D2 AC Models Check the coil polarity when wiring and wire all connections correctly. (The coil has no polarity.) Check the coil polarity when wiring and wire all connections correctly. Terminal Arrangement/Internal Connections (Bottom View) LY2(Z) LY2(Z)-D (The coil has no polarity.) Check the coil polarity when wiring and wire all connections correctly. 0.5 Eight, 3-dia. holes 36 max. 3 6.4 LY2(Z)N 28 max. DC Models 5 AC Models LY2(Z)N-D2 21.5 max. Note: 1. For the DC models, check the coil polarity when wiring and wire all connections correctly. 2. The indicator is red for AC and green for DC. 3. The operation indicator indicates the energization of the coil and does not represent contact operation. Check the coil polarity when wiring and wire all connections correctly. (The coil has no polarity.) Check the coil polarity when wiring and wire all connections correctly. 10 LY LY3 LY3N LY3-D LY3N-D2 LY3 Terminal Arrangement/Internal Connections (Bottom View) LY3-D 0.5 28 max. (The coil has no polarity.) 5 36.5 max. 3 6.4 Check the coil polarity when wiring and wire all connections correctly. 31.5 max. Eleven, 3-dia. holes LY3N-D2 LY3N DC Models AC Models Check the coil polarity when wiring and wire all connections correctly. Check the coil polarity when wiring and wire all connections correctly. (The coil has no polarity.) Note: 1. For the DC models, check the coil polarity when wiring and wire all connections correctly. 2. The indicator is red for AC and green for DC. 3. The operation indicator indicates the energization of the coil and does not represent contact operation. LY4 LY4N LY4-D LY4N-D2 Terminal Arrangement/Internal Connections (Bottom View) LY4 LY4-D 0.5 28 max. (The coil has no polarity.) 5 36 max. 3 6.4 Check the coil polarity when wiring and wire all connections correctly. 41.5 max. Fourteen, 3-dia. holes LY4N-D2 LY4N DC Models AC Models Check the coil polarity when wiring and wire all connections correctly. Check the coil polarity when wiring and wire all connections correctly. (The coil has no polarity.) Note: 1. For the DC models, check the coil polarity when wiring and wire all connections correctly. 2. The indicator is red for AC and green for DC. 3. The operation indicator indicates the energization of the coil and does not represent contact operation. LY2-CR LY2Z-CR LY2N-CR LY2ZN-CR Terminal Arrangement/Internal Connections (Bottom View) LY2(Z)-CR LY2(Z)N-CR 0.5 Eight, 3-dia. holes* 28 max. 5 3 53 max. CR element C = 0.033 μF R = 120 Ω 21.5 max. 6.4 *These dimensions are for the LY2N-CR. (The coil has no polarity.) 11 LY Relays with PCB Terminals LY1-0, LY3-0, LY2-0, and LY4-0 PCB Processing Dimensions (Bottom View) 1 pole 2 poles 3 poles 4 poles 28 max. 21.5 max. 36 max. Five, 2.5-dia. holes Note: The figures and dimensions depicted here are for the LY2-0. The dimension with an asterisk (*) is 6.4 for the LY1-0. Eight, 2.5-dia. holes Eleven, 2.5-dia. holes Fourteen, 2.5-dia. h Note: 1. The dimensional tolerance is 0.1 mm. 2. There are exposed parts (conductive parts) on the LY1-0 other than the terminals. Be careful when using this Relay on a double-sided PCBs. Terminal Arrangement/Internal Connections (Bottom View) LY1-0 LY2-0 LY3-0 LY4-0 2 3 6 7 8 (The coil has no polarity.) Case-surface mounting LY1F LY2F Mounting Hole Dimensions 22.5 max. Terminal Arrangement/Internal Connections (Bottom View) LY1F LY2F 44 max. 29 max. Two, 3.5-dia. holes or two M3 screw holes Eight, 2-dia. holes* 35.5 max. (The coil has no polarity.) Note: The dimensional tolerance is ±0.1 mm. Note: The figures and dimensions depicted here are for the LY1F. The LY2F is also conforms to these measurements. LY3F Mounting Hole Dimensions 32 max. Terminal Arrangement/Internal Connections (Bottom View) LY3F 28.5 max. 44 max. Two, 3.5 dia. holes or two M3 screw holes Eleven, 3-dia. holes (The coil has no polarity.) 36 max. LY4F Mounting Hole Dimensions 41.5 max. Terminal Arrangement/Internal Connections (Bottom View) LY4F Three, 3.5 dia. holes or two M3 screw holes 28 max. Fourteen, 3-dia. holes 44 max. (The coil has no polarity.) 35.5 max. 12 LY Connection Sockets Terminal Arrangement/ Internal Connections Dimensions PTF-08-PU(-L) Mounting Hole Dimensions Two, M3 screw hole or two, 3.5 dia. hole 66.2 48.2 45 36.3 27.6 3.9 (4.2) 21 (6) 24 (4) 14 (5) 11 (3) 22 (2) 12 (1) 108 90 35.3 (8) A2 27.4 Release lever * (4.2) 24.8 27.6 28.1 30.3 * The PTF-08-PU-L Sockets do not have release levers. PTF08A Two, 4.5 × 6 mounting holes (7) A1 (Top View) Note: The numbers in parentheses are traditionally used terminal numbers. (Top View) Note: Pull out the hooks to mount the Relay with screws. 3.4 7±0.2 8-M3.5×8 78.5 max. 35.4 Two, 4.5 dia. or M4 mounting holes 2 1 8 30 max. 28.5 max. 4 3 PTF08A-E (Finger Protection Structure) Two, 4.5 × 6 mounting holes 68±0.3 3.4 8-M3.5×8 6 5 8 7 (Top View) 19±0.2 (Top View) 78.5 max. 35.5 Note: Track mounting is also possible. 8 28.5 max. 33 max. PTF11A Two, 4.5 × 6 mounting holes Two, 4.5 × 6 mounting holes 3.4 7±0.2 11-M3.5×8 3 2 1 6 5 4 68±0.3 35.4 78.5 max. 9 8 7 11 37 max. 8 30 max. 10 (Top View) 27.5±0.2 (Top View) Note: Track mounting is also possible. 13 LY Terminal Arrangement/ Internal Connections Dimensions Mounting Hole Dimensions PTF-14-PU-L 41 48.2 45 36.3 43.4 31 (12) (11) 44 (8) 27.6 3.9 42 (4) (4.2) 34 (7) 32 (3) 21 Two, M3 screw hole or two, 3.5 dia. hole 11 (9) (10) 24 14 (6) 22 (5) 12 (2) (1) 27.4 108 90 35.3 (14) A2 (13) A1 (Top View) (4.2) Note: The numbers in parentheses are traditionally used terminal numbers. 27.6 28.1 30.3 PTF14A Two, 4.5 × 6 mounting holes (Top View) Note: Pull out the hooks to mount the Relay with screws. 3.4 7±0.2 14-M3.5×8 78.5 max. 35.4 Two, 4.5 dia. or M4 mounting holes 4 3 2 1 45.5 max. 8 30 max. 8 7 6 5 PTF14A-E (Finger Protection Structure) Two, 4.5 × 6 mounting holes 68±0.3 3.4 7±0.2 12 11 10 9 14-M3.5×8 14 13 (Top View) 36±0.2 (Top View) 78.5 max. 35.5 Note: Track mounting is also possible. 45.5 max. 8 33 max. Note: If you use the PTF-08-PU, PTF-08-PU-L, PTF08A, PTF08A-E, or PT08 with an LY1 Relay, connect the following terminal pairs: 1-2, 3-4, and 5-6 (for usage at 10 A or higher). 14 LY Terminal Arrangement/ Internal Connections Dimensions PT08 Mounting hole and PCB dimensions PT08QN 5 1.5×1.0 0.3 25.5 29.5 1.0 max. max. 25.5 29.5 max. max. 2.7 2.7 24 max. 20.5 max. 2 9 2.5 20 1.5 35 max. 25.8±0.2 21.4+0.2 0 2 24 max. 1 2 3 4 5 6 Eight, 1.7-dia × 3.5 oblong holes PT08-0 2 0.3 *Maintain a sufficient distance from the pattern when using double-sided PCBs. • The structure does not resist flux. Manual soldering is recommended for this product. 7 15.6 10 8 (Bottom View) 5.35 4.6 6.45 29.5 max. 2 1 5* 6.5 6.5 4.3 3 22 max. Eight, 2.5-dia. holes (±0.1 tolerance) 18 max. PT11 12.45 PT11QN 0.3 1.5×1.0 5 1.5 30.6 32 max. Eleven, 1.7-dia × 3.5 holes 31±0.2 32 30.6 max. 2.7 9 2.5 20 2.7 1.2 1.0 26.4 1.2 35 max. 26.6+0.3 0 29.5 max. 26.4 10 7 4 1 8 5 2 11 9 6 3 29.5 max. 20.5 max. PT11-0 * 0.3 Maintain a sufficient distance from the pattern when using double-sided PCBs. • The structure does not resist flux. Manual soldering is recommended for this product. (Bottom View) 12.45 6.45 4.6 Eleven, 2.5-dia. holes 5.2 10 21.4 2 5* 10 32 max. 5.8 2.7 4.3 18 max. PT14 6.2 6.2 5.65 (±0.1 tolerance) 29.5 max. PT14QN 0.3 1.5×1.0 5 Fourteen, 1.7-dia × 3.5 holes 42.5 max. 1.5 42.5 max. 2.7 9 2.5 1.0 20 35 max. 26.5 max. 29.5 max. 2.7 20.5 max. 26.5 max. 29.5 max. PT14-0 *Maintain 0.3 41±0.2 a sufficient distance from the pattern when using double-sided PCBs. • The structure does not resist flux. Manual soldering is recommended for this product. 26.6+0.3 0 13 9 5 1 10 6 2 11 7 3 14 12 8 12.45 4.6 6.45 4 5.1 5.8 (Bottom View) 10 31.4 2 2.7 4.3 10 42.5 max. 5* 10 Fourteen, 2.5-dia. holes 6.4 6.4 17.5 max. 26.5 max. 29.5 max. 5.45 (±0.1 tolerance) Note: Use a panel with a thickness of 1 to 2 mm when mounting a Socket on it. 15 LY Hold-down Clips PYC-A1 PYC-P Approx. 0.54 g (per clip) One Set (2 Clips) PYC-S Approx. 1.4 g Y92H-3 Approx. 1.8 g PYC-1 Approx. 0.7 g (per clip) One Set (2 Clips) Approx. 6 g Approx. 5 9.4 Approx. 5 8 5 Approx. 29 28 28 Approx. 3 2.5 53 36.3 52 58.2 38.5 4.5 4.5 1.2 4.5 4.5 1.2 Socket Mounting Plates (t = 1.6) OMRON can provide Socket Mounting Plate for convenient Socket installation. Please use these Plates as required. PYP-1 PYP-18 PYP-36 492 21.6 72, oval holes 492 17×27.4 = 465.8±0.6 13.1 4.5 Two, 3.4-dia. holes 3.4 21.6 27.4×17 = 465.8±0.6 ±0.15 13.1 27.4 4.5 3.4 R1.7 21.4 +0.2 0 72, oval holes R1.7 5.1 5.1 42 39.7±0.2 5.1 42±0.1 49 49 86.4 39.7±0.2 28 21.6 17×27.4 = 465.8±0.6 13.1 17×27.4 = 465.8±0.6 21.6 27.4×17 = 465.8±0.6 PTP-1-3 PTP-12 49 42±0.1 7.7 13 48, oval holes 11×39.4 = 433.4±0.6 7.7 42±0.1 49 R5 42±0.1 49 3.4 Four, 3.4-dia. holes R2.25 4.5 11×39.4 = 433.4±0.6 11×39.4 = 433.4±0.6 12, square holes 29.3 492 PTP-1 PTP-10 59 Four, 3.4-dia. holes 7.4 R5 40, oval holes 9×49.4 = 444.6±0.6 7.7 7.7 42±0.1 49 42±0.1 49 R1.7 52±0.1 1.1 3.4 4.5 9×49.4 = 444.6±0.6 9×49.4 = 444.6±0.6 7.4 23.7 492 16 LY Connection Socket and Hold-down Clip Application Table Item Applicable Relay • • • • • Standard models: LY@ Bifurcated contact models: LY@Z Models with built-in operation indicators: LY@N Models with built-in diodes: LY@-D(2) Models with built-in CR circuits: LY@-CR Number of poles PTF-08PU 1 or 2 Front-mounting Sockets Back-mounting Sockets Track or screw mounting Solder terminals, wrapping terminals, or PCB terminals PTF-08PTF-14PTF08A PTF11A PTF14A PU-L PU-L *  Applicable Hold-down Clips  Applicable PT08(QN) PT11(QN) PT14(QN) Hold-down PT08-0 PT11-0 PT14-0 Clips  3   PYC-A1 4  2  PYC-P   Y92H-3   PYC-1 * A Release Lever is provided as a standard feature. The hold-down clips are unnecessary. Mounting Height with Sockets Front-mounting Sockets Back-mounting Sockets LY 66.2 64.1 28.1 (3.9) PTF-@-PU Note: 1. The PTF@A can be mounted on a track or with screws. 2. The measurements in parentheses are for the LY@-CR (built-in CR circuit). Safety Precautions Refer to the Common Relay Precautions for precautions that apply to all Relays. Precautions for Correct Use • Use two M3 screws to attach case-surface-mounted models (LY1F, LY2F, LY3F, and LY4F) and tighten the screws securely. (Normal tightening torque: 0.98 N·m) • For Relays with Tab Terminals, select a wire diameter for the lead wires that connect to the faston receptacle terminals that is within the allowed range for the load current. • Do not impose excessive external force on the Relay when inserting the Relay to the faston receptacle or pulling the Relay out from the faston receptacle. Do not attempt to insert a terminal diagonally or insert or pull out more than one terminal at the same time. • LY Single-contact Relays are for power switching applications. Do not use the LY Series for switching minute loads of 100 mA or less, such as signals. About the Built-in Diode and CR Elements The diode or CR element that are built into the Relay are designed to absorb the reverse voltage from the Relay coil. If a large surge in voltage is applied to the diode or CR element from an external source, the element will be destroyed. If there is the possibility of large voltage surges that could be applied to the elements from an external source, take any necessary surge absorption measures. Applying 10 A or More When Using an LY1 with the Following Sockets When you use an LY1 in combination with the PTF-08-PU, PTF-08PU-L, PTF08A, PTF08A-E, or PT08, connect each of the following terminal pairs: (1) to (2), (3) to (4), and (5) to (6). Relay Replacement To replace the Relay, turn OFF the power supply to the load and Relay coil sides to prevent unintended operation and possible electrical shock. Attaching and Removing Relay Hold-down Clips When you attach a Hold-down Clip to or remove it from a Socket, wear gloves or take other measures to prevent injuring your fingers on the Hold-down Clip. 17 OMRON AUTOMATION AMERICAS HEADQUARTERS • Chicago, IL USA • 847.843.7900 • 800.556.6766 • automation.omron.com OMRON CANADA, INC. • HEAD OFFICE Toronto, ON, Canada • 416.286.6465 • 866.986.6766 • automation.omron.com OMRON ELETRÔNICA DO BRASIL LTDA • HEAD OFFICE São Paulo, SP, Brasil • 55.11.2101.6300 • www.omron.com.br OMRON ELECTRONICS DE MEXICO • HEAD OFFICE Ciudad de México • 52.55.5901.4300 • 01.800.386.6766 • mela@omron.com OMRON ARGENTINA • SALES OFFICE Buenos Aires, Argentina • +54.11.4521.8630 • +54.11.4523.8483 mela@omron.com OMRON ELECTRONICS DE MEXICO • SALES OFFICE San Pedro Garza García, N.L. • 81.12.53.7392 • 01.800.386.6766 • mela@omron. com OTHER OMRON LATIN AMERICA SALES +54.11.4521.8630 • +54.11.4523.8483 • mela@omron.com OMRON ELECTRONICS DE MEXICO • SALES OFFICE Eugenio Garza Sada,León, Gto • 01.800.386.6766 • mela@omron.com Controllers & I/O • Machine Automation Controllers (MAC) • Motion Controllers • Programmable Logic Controllers (PLC) • Temperature Controllers • Remote I/O Authorized Distributor: Robotics • Industrial Robots • Mobile Robots Operator Interfaces • Human Machine Interface (HMI) Motion & Drives • Machine Automation Controllers (MAC) • Motion Controllers • Servo Systems • Frequency Inverters Vision, Measurement & Identification • Vision Sensors & Systems • Measurement Sensors • Auto Identification Systems Sensing • Photoelectric Sensors • Fiber-Optic Sensors • Proximity Sensors • Rotary Encoders • Ultrasonic Sensors Safety • Safety Light Curtains • Safety Laser Scanners • Programmable Safety Systems • Safety Mats and Edges • Safety Door Switches • Emergency Stop Devices • Safety Switches & Operator Controls • Safety Monitoring/Force-guided Relays Control Components • Power Supplies • Timers • Counters • Programmable Relays • Digital Panel Meters • Monitoring Products Switches & Relays • Limit Switches • Pushbutton Switches • Electromechanical Relays • Solid State Relays Software • Programming & Configuration • Runtime RL174-E-01 Note: Specifications are subject to change. © 2019 Omron. All Rights Reserved. Printed on recycled paper. Printed in U.S.A.
LY4-AC12
物料型号: - 该文档描述了多种型号的“Bi-power Relays LY”,包括符合UL、CSA和SEV安全标准以及电气设备和材料安全法的型号。 - 型号结构包括带插拔端子的继电器、带PCB端子的继电器、表面贴装继电器等。

器件简介: - 这些是通用的功率切换继电器,具有紧凑的尺寸。 - 它们配备了用于电弧中断的弧障,并能承受高达2000V的电压。 - 新增了内置二极管和内置CR电路的型号。

引脚分配: - 文档提供了详细的型号分类和结构,包括单极和多极继电器的端子分配和接线图。

参数特性: - 包括工作线圈电压、额定电流、线圈电阻、线圈电感、必须操作电压、必须释放电压、最大电压和功耗等。

功能详解: - 继电器具备多种功能,如内置操作指示器、内置二极管用于线圈浪涌吸收、内置CR电路等。

应用信息: - 继电器适用于多种应用场景,包括但不限于电机驱动、照明控制、电容充放电等。

封装信息: - 提供了继电器的尺寸、安装孔尺寸、端子排列和内部连接的详细信息。
LY4-AC12 价格&库存

很抱歉,暂时无法提供与“LY4-AC12”相匹配的价格&库存,您可以联系我们找货

免费人工找货
LY4-AC12
  •  国内价格 香港价格
  • 1+153.921971+19.09395
  • 10+134.4504210+16.67852
  • 25+127.4083925+15.80496
  • 50+122.3260650+15.17449
  • 100+117.44765100+14.56933
  • 250+111.29417250+13.80599
  • 500+106.85454500+13.25526

库存:20