M30-PHWS 数据手册
E2K-X E2K-X Capacitive Prox E2K-X Threaded, Cylindrical Sensor Detects Metallic and Non-metallic Objects ■ Permits non-contact detection of metallic and non-metallic objects such as glass, wood, water, oil and plastic ■ Allows indirect detection of materials inside non-metallic containers ■ Built-in amplifier accepts a wide range of supply voltages and switches up to 200 mA ■ LED indicator and fixed sensitivity for simple installation Ordering Information ■ 3-WIRE DC SENSORS Size Type Nominal detecting distance Part NPN-NO number NPN-NC PNP-NO PNP-NC M12 Unshielded 4 mm (0.16 in) E2K-X4ME1 E2K-X4ME2 E2K-X4MF1 E2K-X4MF2 M18 M30 8 mm (0.32 in) E2K-X8ME1 E2K-X8ME2 E2K-X8MF1 E2K-X8MF2 15 mm (0.59 in) E2K-X15ME1 E2K-X15ME2 E2K-X15MF1 E2K-X15MF2 M12 Unshielded 4 mm (0.16 in) E2K-X4MY1 E2K-X4MY2 M18 M30 8 mm (0.32 in) E2K-X8MY1 E2K-X8MY2 15 mm (0.59 in) E2K-X15MY1 E2K-X15MY2 ■ 2-WIRE AC SENSORS Size Type Nominal detecting distance Part SCR-NO number SCR-NC ■ ACCESSORIES Description Mounting brackets for standard size sensors Part number Y92E-B12 Y92E-B18 Y92E-B30 Fits M12 size sensors Fits M18 size sensors Fits M30 size sensors 2 E2K-X E2K-X ■ REPLACEMENT PARTS Description Mounting hardware includes one pair of plastic nuts Part number M12-PHWS M18-PHWS M30-PHWS Fits M12 size sensors (supplied with each sensor) Fits M18 size sensors (supplied with each sensor) Fits M30 size sensors (supplied with each sensor) Specifications ■ 3-WIRE DC SENSORS Part number Sensor type Body Size Type Supply voltage Current consumption E2K-X4M❑❑ Capacitive M12 Unshielded 10 to 30 VDC 8 mA at 12 VDC 15 mA at 24 VDC E2K-X8M❑❑ E2K-X15M❑❑ M18 M30 Detectable object type Sensitivity Effective maximum detecting distance (with standard target) Metallic and non-metallic objects Fixed 4 mm 8 mm (0.16 in) (0.32 in) Standard target size (grounded mild steel, L x W x H) 50 x 50 x 1 mm (2.0 x 2.0 x 0.04 in) Differential travel Control output DC solidstate 20% max. of effective maximum detecting distance Type Max. load Max. on-state voltage drop Response frequency Circuit Output shortprotection circuit DC power supply reverse polarity NPN-NO open collector with pull-up (E2K-X❑❑ME1) NPN-NC open collector with pull-up (E2K-X❑❑ME2) PNP-NO open collector with pull-down (E2K-X❑❑MF1) PNP-NC open collector with pull-down (E2K-X❑❑MF2) 200 mA 1 VDC 100 Hz Not provided Provided Weld field immunity RFI immunity Not provided Not provided Target Present (red LED) Housing Sensing face Cable sheath ABS ABS Polyethylene Two metal lock washers and Two metal lock washers and M12 nuts included. Bracket M18 nuts included. Bracket Y92E-B12 optional. Y92E-M18 optional. Three-conductor cable, 2 m (6.56 ft) length Approx. 65 g (2.3 oz.) Approx. 145 g (5.1 oz.) — 1, 4, 12, 13 IP66 — — –25° to 70°C (–13° to 158°F) 10 to 55 Hz, 1.5 mm (0.06 in) double amplitude Approx. 50 G’s Indicators Materials 15 mm (0.59 in) Mounting Connections Weight with cable Enclosure UL ratings NEMA IEC 144 Approvals UL CSA Ambient operating temperature Vibration Shock 3 Two metal lock washers and M30 nuts included. Bracket Y92E-M30 optional. Approx. 205 g (7.2 oz.) –10° to 55°C (14° to 131°F) E2K-X E2K-X ■ 2-WIRE AC SENSORS Part number Sensor type Body Supply voltage Current consumption Detectable object type Sensitivity Effective maximum detecting distance (with standard target) E2K-X4MY❑ E2K-X8MY❑ Capacitive M12 M18 Unshielded 90 to 250 VAC, 50/60 Hz 2.2 mA at 200 VAC Metallic and non-metallic objects Fixed 4 mm 8 mm (0.16 in) (0.32 in) Standard target size (grounded mild steel, L x W x H) 50 x 50 x 1 mm (2.0 x 2.0 x 0.04 in) Differential travel 20% max. of effective detecting distance Control output AC solidstate Size Type Type 200 mA See “Leakage Current Characteristics” graph in Engineering Data section See “Residual Load Voltage Characteristics” graph in Engineering Data section 10 Hz Not provided Materials ABS ABS Polyethylene Two metal lock washers and M12 nuts included. Bracket Y92E-B12 optional. Mounting Connections Weight with cable Enclosure UL ratings NEMA IEC 144 Approvals UL CSA Ambient operating temperature Vibration Shock M30 15 mm (0.59 in) SCR-NO (E2K-X❑❑Y1) SCR-NC (E2K-X❑❑Y2) Max. load Max. off-state leakage current Max. on-state voltage drop Response frequency Circuit Output shortprotection circuit Weld field immunity RFI immunity Indicators Housing Sensing face Cable sheath E2K-X15MY❑ Not provided Not provided Output Operation (red LED) Two metal lock washers and M18 nuts included. Bracket Y92E-B18 optional. Two-connector cable, 2 m (6.56 ft) length Approx. 65 g (2.3 oz.) Approx. 145 g (5.1 oz.) — 1, 4, 12, 13 IP66 Recognized, File Number E76675 Certified, File Number LR45951 –25° to 70°C (–13° to 158°F) 10 to 55 Hz, 1.5 mm (0.06 in) double amplitude Approx. 50 G's 4 Two metal lock washers and M30 nuts included. Bracket Y92E-B30 optional. Approx. 205 g (7.2 oz.) –10° to 55°C (14° to 131°F) E2K-X E2K-X Operation ■ OUTPUT DIAGRAMS AND TIMING CHARTS DC Switching Types E2K-X❑ME❑ NPN E2K-X❑MF❑ PNP The dotted line shows a transistor circuit load. Brown (Red) +V Black Load (White) 4.7 K Ω Prox. switch main circuit The dotted line shows a transistor circuit load. Brown (Red) +V 2.2 Ω Prox. switch main circuit Output Tr 2.2 Ω Black (White) Tr Output Load Blue (Black) 4.7 K Ω Blue (Black) 0V 0V 200 mA max. source current. 200 mA max. source current. Note: IEC colors are shown in parentheses. E2K-X❑ME1 NO Target Target Present Absent Load (between black and white) Operates Releases Operates Releases H L Logic (between white and red) H L H L ON OFF Operation indicator (LED) ON OFF ON OFF Present Absent Operates Releases Operates Releases Logic (between white and black) H L Operation indicator (LED) ON OFF AC Switching Types E2K-X❑MY❑ White (Black) Load Prox. switch main circuit Black (Blue) E2K-X❑MY1 NO Target Load Operation indicator (LED) E2K-X❑MF2 NC Present Absent Present Absent Load (between red and white) E2K-X❑MF1 NO E2K-X❑ME2 NC E2K-X❑MY2 NC Present Absent Present Absent Operates Releases Operates Releases ON OFF ON OFF 5 E2K-X E2K-X Engineering Data Operating Range E2K-X❑M❑❑ 18 16 E2K-X15M 14 X 12 Y 10 Standard target: Grounded metal plate 50x50x1mm 8 E2K-X8M 6 4 E2K-X4M 2 0 –25 –20 25 –15 –10 –5 0 5 10 15 20 E2K-X4M detecting head E2K-X8M detecting head E2K-X15M detecting head Detecting Distance vs. Size and Material of Target E2K-X8M❑❑ 5 E2K-X15M❑❑ 25 10 Ungrounded metal t3 X 2 X ❑ 3 ❑ 1 t3 t3 Grounded metal 4 Detecting distance X (mm) Detecting distance X (mm) X 8 6 ❑ Grounded metal Detecting distance X (mm) E2K-X4M❑❑ Ungrounded metal 4 Glass 20 Grounded metal 15 Ungrounded metal 10 Glass Phenolic resin 5 2 Acrylic resin Phenolic resin Glass Acrylic resin Phenolic resin 0 10 20 30 40 50 Size of target (mm) 60 70 0 10 20 30 40 50 Size of target (mm) 60 70 0 10 20 30 40 50 Size of target (mm) 60 70 Detecting Distance vs. Thickness and Material of Target E2K-X4M❑❑ E2K-X8M❑❑ E2K-X15M❑❑ 5 10 25 4 8 20 3 50❑ Ungrounded metal 2 Glass 1 5 10 15 20 Thickness of target t (mm) Grounded metal 50❑ 6 Ungrounded metal Glass 4 Phenolic resin Ungrounded metal 15 X t 50❑ Glass 10 Phenolic resin Acrylic resin 5 2 Phenolic resin 0 t X Detecting distance X (mm) Grounded metal t X Detecting distance X (mm) Detecting distance X (mm) Grounded metal Acrylic resin 25 0 5 10 15 Thickness of target t (mm) 6 20 25 0 5 10 15 20 Thickness of target t (mm) 25 E2K-X E2K-X Residual Load Voltage Characteristics AC switching types 100 VAC 200 VAC 120 240 200 100 Residual output voltage ON Load voltage VL (V) Load voltage VL (V) Residual output voltage ON 160 80 VL VL 120 60 100 VAC 40 200 VAC 80 40 20 Residual load voltage Residual load voltage OFF OFF 0 3 5 10 30 50 Load current (mA) 100 200 0 3 5 10 30 50 Load current (mA) 100 200 Note: When the current rating of the load is less than 10 mA, false operation may occur. This is normal, and the problem can be cured by installing a bleeder resistor in parallel with the load. Use the formulas given here to calculate the power rating and value of the resistor. Leakage Current Characteristics AC switching types E2K-X❑MY❑ Leakage current (mA) 2.0 1.5 Protective resistor (OFF state) AC power supply (50/60Hz) 1.0 0 100 200 Supply voltage (V) 300 7 R < Vs (kΩ) = 10 – i 2 P > Vs (mW) R P : Power rating of bleeder resistor i : Load current (mA) Vs : Supply voltage (V) E2K-X E2K-X Dimensions ■ SENSORS Unit: mm E2K-X4M❑❑ E2K-X8M❑❑ 80 (3.05) 17 (0.67) across flats 2,000 (78.74) 60 (2.36) 20 (0.79) 4 4 (0.16) Cable: 4 mm OD 2 m (6.56 ft) length 2,000 (78.74) 60 (2.36) 20 (0.79) Indicator M12 x 1 Two–clamping nuts Two–toothed washers 12.5 (0.49) dia. 80 (3.05) 24 (0.94) across flats 4 4 (0.16) Indicator M18 x 1 Two–clamping nuts Two–toothed washers 18.5 (0.73) dia. Cable: 6 mm OD 2 m (6.56 ft) length E2K-X15M❑❑ 80 (3.05) 36 (1.42) across flats 2,000 (78.74) 60 (2.36) 10 (0.39) 5 (0.20) 5 Indicator M30 x 1.5 Two–clamping nuts Two–toothed washers 30.5 (1.20) dia. Cable: 6 mm OD 2 m (6.56 ft) length ■ OPTIONAL MOUNTING BRACKETS F A Part number B Y92E-B12 Y92E-B18 Y92E-B30 Drawing dimensions A B C 24 ± 0.2 12.5 max. 20 32 ± 0.2 17 max. 30 45 ± 0.2 17 max. 50 D 12 dia. 18 dia. 30 dia. E 37 max. 37 max. 60 max. F M4 x 25 bolt M5 x 32 bolt M5 x 50 bolt Applicable sensor models E2K-X4M❑❑ E2K-X8M❑❑ E2K-X15M❑❑ C D E Precautions ■ TIGHTENING FORCE Part number E2K-X4M❑❑ E2K-X8M❑❑ E2K-X15M❑❑ Do not exceed the torque listed in the table at right when tightening the mounting nuts. 8 Maximum torque kg-cm in-lbs 8 7 20 17 20 17 E2K-X E2K-X ■ EFFECTS OF SURROUNDING METAL When mounting the proximity sensor in or near a metallic panel, be sure to provide a minimum distance as shown in the tables below. This prevents the sensor from being affected by metallic objects other than the target. When Mounting Directly to Metal Panel or Object Drawing dimension d (dia.) D m n Sensor model E2K-X4M❑❑ 20 mm (0.79 in) 50 mm (1.97 in) 20 mm (0.79 in) 8 mm (0.32 in) 60 mm (2.36 in) E2K-X8M❑❑ 20 mm (0.79 in) 50 mm (1.97 in) 20 mm (0.79 in) 12 mm (0.47 in) 60 mm (2.36 in) E2K-X15M❑❑ 10 mm (0.39 in) 50 mm (1.97 in) 10 mm (0.39 in) 25 mm (0.98 in) 60 mm (2.36 in) m n ød D To ground Metal When Using Optional Mounting Brackets G Drawing dimension G H Sensor model E2K-X4M❑❑ 20 mm (0.79 in) 30 mm (1.18 in) E2K-X8M❑❑ 20 mm (0.79 in) 30 mm (1.18 in) E2K-X15M❑❑ 10 mm (0.39 in) 30 mm (1.18 in) H ■ MUTUAL INTERFERENCE To prevent mutual interference between two sensors, be sure to space the two sensors at a distance greater than that shown in the table below. Drawing dimension A B Sensor model E2K-X4M❑❑ 80 mm (3.15 in) 70 mm (2.76 in) E2K-X8M❑❑ 150 mm (5.91 in) 110 mm (4.33 in) E2K-X15M❑❑ 300 mm (11.81 in) 200 mm (7.87 in) B A ■ REQUIRED WARM-UP TIME BEFORE OPERATION DC Switching Sensors AC Switching Sensors In applying any of the E2K-X❑ME series proximity sensors as a voltage output type, note that an unwanted output may be produced momentarily (50 ms max.) when power is applied with a target moving toward the E2K-X❑ME1(F1) or with a target moving away from the E2K-X❑ME2(F2). After the power application, a minimum of 50 ms is required before the sensor circuit can operate. Move the target toward or away from the proximity sensor after this time period. After applying power to a proximity sensor, a minimum of 100 ms is required before the sensor circuit reaches its steady state. The load is in the OFF state during this period. Do not move the target toward or away from the proximity sensor until the sensor circuit enters the steady state. The operation indicator (LED) will illuminate momentarily when the power is turned ON or OFF, but the output stage circuit is in a normal operating state. ■ USING METAL CONDUIT If a high voltage or power line runs near the proximity sensor cable, be sure to wire the sensor cable through a metal conduit to protect the sensor from malfunctioning or damage. ■ SURGE PROTECTION The proximity sensor is provided with a surge suppressor circuit. However, if any large surge generation source (i.e. motor, welding machine, etc.) exists in the vicinity of the proximity sensor, insert a surge suppressor (such as a varistor) into the surge generating source. 9 E2K-X E2K-X OMRON ELECTRONICS LLC OMRON ON-LINE OMRON CANADA, INC. One East Commerce Drive Schaumburg, IL 60173 Global - http://www.omron.com USA - http://www.omron.com/oei Canada - http://www.omron.com/oci 885 Milner Avenue Scarborough, Ontario M1B 5V8 1-800-55-OMRON Cat. No. CEDSAX4 11/01 Specifications subject to change without notice. 416-286-6465 Printed in the U.S.A. Mouser Electronics Authorized Distributor Click to View Pricing, Inventory, Delivery & Lifecycle Information: Omron: M18-PHWS M30-PHWS
M30-PHWS
物料型号: - 3线直流传感器:E2K-X4ME1, E2K-X8ME1, E2K-X15ME1, E2K-X4ME2, E2K-X8ME2, E2K-X15ME2, E2K-X4MF1, E2K-X8MF1, E2K-X15MF1, E2K-X4MF2, E2K-X8MF2, E2K-X15MF2 - 2线交流传感器:E2K-X4MY1, E2K-X8MY1, E2K-X15MY1, E2K-X4MY2, E2K-X8MY2, E2K-X15MY2

器件简介: E2K-X系列传感器能够非接触式检测金属和非金属物体,如玻璃、木头、水、油和塑料。它们还允许间接检测非金属容器内的物质。

引脚分配: - 3线直流传感器:棕色线为Vcc,蓝色线为输出,黑色线为地 - 2线交流传感器:白色线为Vcc,黑色线为输出

参数特性: - 供电电压范围:直流传感器为10至30VDC,交流传感器为90至250VAC - 检测距离:4mm、8mm、15mm - 工作频率:直流传感器为100Hz,交流传感器为10Hz - 输出类型:直流为NPN或PNP型,交流为SCR型

功能详解: - 内置放大器接受宽范围的供电电压,并可切换高达200mA的电流 - 具有LED指示器和固定灵敏度,便于安装

应用信息: 适用于需要检测金属和非金属物体的场合,例如工业自动化、机器人技术等。

封装信息: - 尺寸:M12、M18、M30 - 材料:ABS塑料外壳,聚乙烯电缆护套 - 安装:包括两个金属锁紧垫圈和相应尺寸的螺母,可选配安装支架