OS32C-WIN-KT

OS32C-WIN-KT

  • 厂商:

    OMRON(欧姆龙)

  • 封装:

    -

  • 描述:

    WIN-KTWINDOWREPLACEMENTKIT

  • 数据手册
  • 价格&库存
OS32C-WIN-KT 数据手册
Safety Laser Scanner OS32C Compact (104.5 mm), lightweight (1.3 kg) and easy-to-install Safety Laser Scanner • Provides a safety circuit of PLd/Safety Category 3 (ISO13849-1) without a dedicated controller. • Type 3 Safety Laser Scanner complies with IEC61496-1/-3. • 70 sets of safety zone and warning zone combinations are available, supporting complicated changes in working environments. • A safety radius up to 4 m and warning zone(s) radius up to 15 m can be set. • The minimum object resolution can be changed to 30, 40, 50 or 70 mm. • The response time is configurable from 80 ms to a maximum of 680 ms. • Reference Boundary Monitoring function prevents unauthorized changes in the scanner position. • Minimal down time, sensor block can be replaced without the need to reprogram. For the most recent information on models that have been certified for safety standards, refer to your OMRON website. Refer to “Safety Precautions” on page 20. Ordering Information OS32C (Power cable is sold separately.) Appearance Description Max. Operating Range (Safety Zone) Model 3m OS32C-BP 4m OS32C-BP-4M 3m OS32C-SP1 Remarks OS32C with back location cable entry OS32C with side location cable entry * OS32C with EtherNet/IP and back location cable entry OS32C with EtherNet/IP and side location cable entry * 4m OS32C-SP1-4M 3m OS32C-BP-DM 4m OS32C-BP-DM-4M 3m OS32C-SP1-DM 4m OS32C-SP1-DM-4M CD-ROM (Configuration tool) OS supported: Windows XP (32-bit version, Service Pack 3 or later) Windows 7 (32-bit version/64-bit version), Windows 8.1 (32-bit version/64-bit version), Windows 10 (32-bit version/64-bit version) For configuration tool version, refer to page 23. * For OS32C-SP1(-DM), each connector is located on the left as viewed from the back of the I/O block. 1 OS32C Power Cable Appearance Description Model Cable length: 3 m OS32C-CBL-03M Cable length: 10 m OS32C-CBL-10M Cable length: 20 m OS32C-CBL-20M Cable length: 30 m OS32C-CBL-30M Description Model Cable length: 2 m OS32C-ECBL-02M Cable length: 5 m OS32C-ECBL-05M Cable length: 15 m OS32C-ECBL-15M Remarks One cable is required per sensor. Ethernet Cable Appearance Remarks Required for configuration and monitoring. Note: An ethernet cable with an M12, 4-pin connector is required. Mounting Brackets Appearance Description Model Bottom/side mounting bracket OS32C-BKT1 XY axis rotation mounting bracket OS32C-BKT2 Remarks Bottom/side mounting bracket x 1, unit mounting screws x 4 sets XY axis rotation mounting bracket x 1, unit mounting screws x 6 sets, bracket mounting screws x 1 set (must be used with OS32C-BKT1) Simple mounting bracket OS32C-BKT3 Protective cover for window OS32C-BKT4 Mounting stand OS32C-MT Hardware kit for mounting stand OS32C-HDT Simple mounting brackets x 2, unit mounting screws x 4 sets * When using a mounting stand, use an OS32C with side location cable entry (OS32C-SP1(-DM)). The OS32C with back location cable entry (OS32C-BP(-DM)) cannot be mounted. Use with mounting brackets (OS32C-BKT1 and OS32C-BKT2). Mounting screws x 3 sets Use this when mounting a bracket to the mounting stand. * There are eight OS32C mounting screws: four screws for singular use, and four screws for protective cover for window. 2 OS32C Accessories Appearance Description Model Scan window OS32C-WIN-KT Sensor block without I/O block Max. Operating Range: 3 m OS32C-SN Remarks Spare for replacement Spare for replacement Sensor block without I/O block Max. Operating Range: 4 m OS32C-SN-4M Sensor block without I/O block for EtherNet/IP Max. Operating Range: 3 m OS32C-SN-DM Spare replacement for EtherNet/IP Sensor block without I/O block for EtherNet/IP Max. Operating Range: 4 m OS32C-SN-DM-4M With cable access from the back OS32C-CBBP Spare for replacement With cable access from the left side OS32C-CBSP1 Spare for replacement I/O block 3 OS32C Rating/Performance Sensor Type Type 3 Safety Laser Scanner Performance Level (PL)/ Safety Category PLd/Safety Category 3 (ISO 13849-1) Functional Safety of Electrical/ SIL 2, PFHD = 8.3 × 10-8 (IEC61508) Electronic/Programmable Electronic Safety-related Systems Detection Capability Configurable; Non-transparent with a diameter of 30, 40, 50, 70mm (1.8% reflectivity or greater) (default: 70 mm) Monitoring Zone Monitoring Zone Set Count: (Safety Zone + 2 Warning Zones) x 70 sets Safety Zone: OS32C-@@@ Operating Range 1.75 m (min. obj. resolution of 30 mm) 2.5 m (min. obj. resolution of 40 mm) 3.0 m (min. obj. resolution of 50 mm or 70 mm) Warning Zone: 10.0 m Safety Zone: OS32C-@@@-4M 1.75 m (min. object resolution of 30mm) 2.5 m (min. object resolution of 40 mm) 3.0 m (min. object resolution of 50 mm) 4.0 m (min. object resolution of 70 mm) Warning Zone: 15.0 m Maximum Measurement Error 100 mm (at range of 3 m or less) *1 110 mm (at distance greater than 3 m and up to 4m) *1 Detection Angle 270° Angular Resolution 0.4° Laser Beam Diameter 6 mm at optics cover, 14 mm (typical) at 3 m. Laser Scan Plane Height 67mm from the bottom of the scanner (see "External Dimensional Drawings" on page 15 for more detail.) Response Time Response time from ON to OFF: From 80 ms (2 scans) to 680 ms (up to 17 scans) *8 Response time from OFF to ON: Response time from ON to OFF + 100 ms to 60 s (Configurable) Zone Switching Time 20 to 320 ms Line Voltage 24 VDC +25%/-30% (ripple p-p 2.5 V max.) *2 Power Consumption Normal operation: 5 W max., 4 W typical (without output load) *3 Standby mode: 3.75 W (without output load) Emission Source (Wavelength) Infrared Laser Diode (905 nm) Laser Protection Class Class 1: IEC/EN60825-1 Class 1: JIS C 6802 Class I: CFR21 1040.10, 1040.11 Safety Output (OSSD) PNP transistor x 2, load current of 250 mA max., residual voltage of 2 V max., load capacity of 2.2 µF max., leak current of 1 mA max. *3, *4, *5 Auxiliary Output (Non-Safety) NPN/PNP transistor x 1, load current of 100 mA max., residual voltage of 2 V max., leak current of 1 mA max. *4, *5, *7 Warning Output (Non-Safety) NPN/PNP transistor x 1, load current of 100 mA max., residual voltage of 2 V max., leak current of 1 mA max. *4, *5, *7 Operation Mode Auto Start, Start Interlock, Start/Restart Interlock Input External Device Monitoring (EDM) ON: 0 V short (input current of 50 mA), OFF: Open Start ON: 0 V short (input current of 20 mA), OFF: Open Zone Select ON: 24 V short (input current of 5 mA), OFF: Open Stand-by ON: 24 V short (input current of 5 mA max.), OFF: Open Connection Type Power Cable: 18-pin mini-connector (pigtail) Communication Cable: M12, 4-pin connector Connection with PC Communication: Ethernet *6 OS Supported: Windows XP (32-bit version, Service Pack 3 or later), Windows 7 (32-bit version/64-bit version), Windows 8.1 (32-bit version/64-bit version), Windows 10 (32-bit version/64-bit version) Indicators RUN indicator: Green, STOP indicator: Red, Interlock Indicator: Yellow, Warning Output Indicator: Orange Status/Diagnostic Display: 2 x 7-segment LEDs, Individual Sector Indicators: Red LED x 8 Protective Circuit Protection against output load short and reverse power connection Ambient Temperature Operation: -10 to 50 °C, Storage: -25 to 70 °C Ambient Humidity Operation & Storage: 95% RH max., non-condensing Ambient Operation Illumination Incandescent lamp: Illumination on receiving surface 1500 lx max. (an angle of laser scanning plane and disturbance light must be +/-5 degrees or more) Insulation Resistance 20 MΩ or higher (500 VDC) Dielectric Withstand Voltage 350VDC, 1 minute Enclosure Rating IP65 (IEC60529) Enclosure Sensor head: Die-cast aluminum, optical cover: Polycarbonate, I/O block: Die-cast aluminum Dimensions (WxHxD) 133.0 x 104.5 x 142.7 mm (except cable) 4 OS32C Impact Resistance 98 m/s2 1,000 times for each of X, Y, and Z directions (IEC60068-2-29) Vibration 10 to 55 Hz double-amplitude of 0.7 mm, 20 sweepings for X, Y, and Z directions (IEC60068-2-6) Weight (Main Unit only) 1.3 kg Power Cable Up to 30 m Communication Cable Up to 100 m for 100BASE-TX cable *9 Approvals Certificated by: TÜV Rheinland, UL Standards: EN61496-1 (Type 3 ESPE), EN61496-3 (Type 3 AOPDDR), EN61508 (SIL2), IEC61496-1 (Type 3 ESPE), IEC61496-3 (Type 3 AOPDDR), IEC61508 (SIL2), UL508, UL1998, CAN/CSA-C22.2 No. 14, CAN/CSA-C22.2 No. 0.8 *1. An additional measurement error may need to be added due to reflective backgrounds. *2. For power source specification, refer to “Safety Precautions” on page 20. *3. Rated current of OS32C is 1.025 A max. (OS32C 210 mA + OSSD A load + OSSD B load + Auxiliary output load + Warning output load + Functional Inputs). Where functional inputs are: EDM input ... 50 mA Start input ... 20 mA Standby input ... 5 mA Zone X input ... 5 mA x 8 (eight zone set select inputs) *4. Output voltage is Input voltage - 2.0 VDC. *5. Total consumption current of 2 OSSDs, auxiliary output, and warning output must not exceed 700 mA. *6. An ethernet cable with an M12, 4-pin connector is required. *7. Output polarity (NPN/PNP) is configurable via the configuration tool. *8. Pollution Tolerance mode will add 6 ms to each scan time. *9. Omron only supplies up to a 15 m Ethernet cable. For longer lengths a connection to a network switch/router is needed. 5 OS32C Connection Basic connection with single OS32C unit Highest achievable PL/ safety category PLd/3 equivalent Model Stop category Reset 0 Manual Safety Laser Scanner OS32C Forced Guided Relay G7SA Note: The above PL is only the evaluation result of the example. The PL must be evaluated in an actual application by the customer after confirming the usage conditions. Application Overview • The power supply to the motor M is turned OFF when an intrusion is detected in the safety zone. • The power supply to the motor M is kept OFF until the start input is pressed after the safety zone is clear. E1 PE 0V Functional Earth (Green) +24V 24VDC (White) 0VDC (Brown) S3 Standby input (Violet) Zone Select 1 (Orange/White) *3 S2 Zone Select 2 (Orange/Black) *3 S2 Zone Select 3 (Gray) *3 S2 Zone Select 4 (Pink) *3 S2 Zone Select 5 (White/Black) *3 S2 Zone Select 6 (Tan) *3 S2 Zone Select 7 (Orange) *3 S2 Zone Select 8 (Blue/White) *3 S2 Start (Black) *2 S1 Auxiliary output (Blue) Warning output (Red/Black) *1 KM1 KM2 EDM (Brown/White) Safety output B (Yellow) S1 : Start Input S2 : Zone Select Switch S3 : Standby Switch KM1, KM2: Forced guided relay (G7SA) or magnetic contactor. M1 : 3-Phase Motor E1 : 24 VDC Power KM1 KM1 KM2 Safety output A (Red) KM2 M1 OS32C Configuration - External Device Monitoring Enabled - Start/Restart Interlock *1.If the External Device Monitoring is not used, connect brown/white wires to 0 V, and then turn OFF the External Device Monitoring with the configuration software. *2.Use NC-contact for a start input. *3.For zone select switch setting, refer to OS32C Series User's Manual (Man.No.Z296-E1). When using only one zone, no connection is needed for the zone select inputs. 6 OS32C Connecting to AGV Controls Highest achievable PL/ safety category PLd/3 equivalent Model Safety Laser Scanner OS32C Stop category Reset 1 Auto The circuit configuration of the stop/deceleration control must meet the requirements of category 3. Note: The above PL is only the evaluation result of the example. The PL must be evaluated in an actual application by the customer after confirming the usage conditions. Application Overview • Stop/deceleration is performed when an intrusion is detected in the safety zone. • Stop/deceleration is released when the safety zone is clear. AGV Controls Functional Earth (Green) Power (24VDC) 24VDC (White) 0VDC (Brown) Zone Control Standby input (Violet) Zone Select 1 (Orange/White) Zone Select 2 (Orange/Black) +24VDC Zone Select 3 (Gray) Zone Select 4 (Pink) Zone Select 5 (White/Black) Zone Select 6 (Tan) Zone Select 7 (Orange) Zone Select 8 (Blue/White) Auxiliary Control Start (Black) 0VDC Auxiliary output (Blue) Warning output (Red/Black) EDM (Brown/White) Stop/Brake Control Safety output B (Yellow) Safety output A (Red) OS32C Configuration - External Device Monitoring Disabled - Automatic Start 7 OS32C Connecting to the Controller G9SA-301 Highest achievable PL/ safety category PLd/3 equivalent Model Stop category Reset 0 Auto Safety Laser Scanner OS32C Safety Relay Unit G9SA-301 Forced Guided Relay G7SA Note: The above PL is only the evaluation result of the example. The PL must be evaluated in an actual application by the customer after confirming the usage conditions. Application Overview • The power supply to the motor M is turned OFF when an intrusion is detected in the safety zone. • The power supply to the motor M is kept OFF until the safety zone is clear. E1 PE 0V +24V Functional Earth (Green) 24VDC (White) 0VDC (Brown) S4 Standby input (Violet) Zone Select 1 (Orange/White) *3 S2 Zone Select 2 (Orange/Black) *3 S2 Zone Select 3 (Gray) *3 S2 Zone Select 4 (Pink) *3 S2 Zone Select 5 (White/Black) *3 S2 Zone Select 6 (Tan) *3 S2 Zone Select 7 (Orange) *3 S2 Zone Select 8 (Blue/White) *3 S2 PLC IN1 IN2 OUT *1 Start (Black) S1 Auxiliary output (Blue) Warning output (Red/Black) EDM (Brown/White) *2 Safety output B (Yellow) Safety output A (Red) ED1 KM1 S3 KM1 KM2 A1 A2 T11 T12 T31 T32 13 23 33 KM2 41 3 4 K1 1 a K2 K1 K1 b K2 K2 a b Control Circuit 2 5 JP 1 2 3 4 5 6 M 6 PE T21 T23 T22 A B 14 KM1 24 34 42 KM2 KM1, KM2: Forced guided relay (G7SA) or magnetic contactor. ED1 : Solid state contactor (G3J) M : 3-Phase Motor S1 : Start Input (use for releasing lockout) S2 : Zone Select Switch S3 : Reset Switch S4 : Standby Switch E1 : 24 VDC Power PLC : Programmable Controller (This is for monitoring only and unrelated to a safety system) Note: Reset setting are below. OS32C: Automatic start, G9SA-301: Manual reset *1. Use NC-contact for a start input. *2. If the External Device Monitoring is not used, connect brown/white wires to 0V, and then turn OFF the External Device Monitoring with the configuration software. *3. For zone select switch setting, refer to OS32C Series User’s Manual (Man.No.Z296-E1). When using only one zone, no connection is needed for the zone select inputs. 8 OS32C System Components and Functions Main Unit (10) (9) (11) (8) (7) (6) (12) (13) (5) (1) (2) Number (3) (4) Component Function (1) RUN indicator (green) Will turn ON when safety zone is clear and OSSDs are ON. (2) Interlock Indicator (yellow) Will turn ON when in interlock state, blink under lockout (@ 1 Hz), and blink under configuration (@ 4 Hz). (3) Status/Diagnostic Display The scanner status, configuration/operation, or failure is displayed. (4) Warning Output Indicator (orange) Will turn ON when the warning output is ON and will flash when dust or contamination is detected on the scan window (@ 1 Hz). (5) STOP indicator (red) Will turn ON when safety zone is blocked, OSSD are OFF or under interlock state. (6) Dust Ring Dust detection cover with reflective surface, for dust accumulation detection (7) Individual Sector Indicators (ISI) Will turn ON when an intrusion is detected in the safety zone (default), 8 sectors total. Each sector = 33.75°. Will flash when dust or contamination is detected on the scan window. (8) Scan window The window where the laser light is emitted and received. (9) Ethernet Connector Used for Ethernet cable connection. * (10) Power Connector 18-pin connector (pigtail). * (11) I/O Block Connector module (12) Center of rotation Indicates the location of the axis around which the laser emits. (13) Sensor block Sensor head; field replaceable. * For OS32C-SP1(-DM), each connector is located on the left as viewed from the back of the I/O block. Status/Diagnostic Display When powered up, the OS32C will display the configured minimum object resolution for 5 seconds, as indicated in the following table: 9 Digital Indication Minimum object resolution L3 30 mm L4 40 mm L5 50 mm L7 70 mm (factory default) OS32C External Dimensional Drawings (Unit: mm [inch]) OS32C with Back Location Cable Entry/with EtherNet/IP and Back Location Cable Entry OS32C-BP OS32C-BP-DM OS32C-BP-4M OS32C-BP-DM-4M Ethernet cable not shown Ethernet connector with M12 cap plug I/O cable 90.4 [3.56] Window 158.3 [6.24] Dust detection I/O block Sensor head 104.3 [4.11] 140.4 [5.53] Top View 100.0 [3.94] 133.0 [5.24] M5 x 0.8, DEPTH 9.0 [0.35] MAX (x4) 32.8 [1.29] 104.5 [4.12] 67.0 [2.64] Scan plane 41.4 [1.63] MTG holes 57.0 [2.25] 27.7 [1.09] Front View 6.0 [0.24] 50.0 [1.97] Side View 50.9 [2.01] 121.0 [4.77] MTG holes Back View 3.0, 10.0, 20.0, or 30.0 Meters 102.9 [4.05] 142.7 [5.62] 30.0 [1.18] dia. OD I/O cable assy 88.1 [3.47] 71.5 [2.82] 71.3 [2.81] (min) Ethernet cable I/O cable 270 (10.63) Bottom View OS32C with Side Location Cable Entry/with EtherNet/IP and Side Location Cable Entry OS32C-SP1 OS32C-SP1-DM OS32C-SP1-4M OS32C-SP1-DM-4M Ethernet 90.4 [3.56] I/O block cable Ethernet cable Window Dust detection I/O cable Sensor head 104.3 [4.11] Top View 140.4 [5.53] 133.0 [5.24] M5 x 0.8, DEPTH 9.0 [0.35] MAX (x4) 32.8 [1.29] 104.5 [4.12] 67.0 [2.64] Scan plane 41.4 [1.63] MTG holes 121.0 [4.77] MTG holes 100.0 [3.94] 70.8 [2.79] Front View 6.0 [0.24] Back View 57.0 [2.25] Side View 50.4 [1.99] 25.0 [0.99] 39.0 [1.54] 18.2 [0.72] I/O cable 270 [10.63] 102.9 [4.05] 142.7 [5.62] 88.2 [3.47] 71.5 [2.82] I/O cable assy 3.0, 10.0, 20.0, or 30.0 Meters 30.0 [1.18] dia. OD Bottom View 10 OS32C OS32C with Top Guard Kit OS32C-BP/OS32C-BP-DM/OS32C-BP-4M/OS32C-BP-DM-4M + OS32C-BKT4 150.4 [5.93] 107.5 [4.24] 93.4 [3.68] 3.0 [0.12] 4-5.6 [0.22] dia. 112.4 [4.43] 63.0 [2.48] 41.4 [1.63] 67.0 [2.64] Scan Plane 27.7 [1.09] 6.0 [0.24] 50.0 [1.97] 145.7 [5.74] 121.0 [4.77] Side View Back View OS32C with Bottom/Side Mounting Brackets OS32C-BP/OS32C-BP-DM/OS32C-BP-4M/OS32C-BP-DM-4M + OS32C-BKT1 103.7 [4.08] 97.7 [3.85] 3-6.4 [0.25] dia. 116.7 [4.60] 39.9 [1.57] 4.9 [0.19] 79.2 [3.12] Scan plane 69.2 [2.73] 12.2 [0.48] 50.0 [1.97] 24.5 [0.97] 37. 9 [1.49] 23.3 [0.92] 41.0 [1.62] 4.2 [0.17] 93.7 [3.69] Back View Side View 155.9 [6.14] 106.0 [4.17] 4-5.3 [0.21] dia. 102.4 [4.03] 66.4 [2.62] 144.4 [5.69] 54.5 [2.15] 23.3 [0.92] Bottom View OS32C with Simple Mounting Bracket OS32C-BP/OS32C-BP-DM/OS32C-BP-4M/OS32C-BP-DM-4M + OS32C-BKT3 103.4 [4.08] 27.7 [1.09] 104.5 [4.12] 67.0 [2.64] 26.8 [1.05] Scan plane 52.8 [2.08] 13.3 [0.52] (×4) 12.0 [0.47] (x4) Slots M5 screws, split and flat washers hardware user supplied 50.0 [1.97] 169.0 [6.66] 155.7 [6.13] Back View Side View 185.0 [7.29] In order to comply with Section 4.2.16 of IEC 61496-3, when the OS32C is mounted where the scanner position could change (e.g. as the result of an impact), additional mechanical means, such as serrated or toothed lock washers, must be employed in the mounting hardware. 11 Bottom View OS32C OS32C with Bottom/Side Mounting Brackets and Top Guard Kit OS32C-BP/OS32C-BP-DM/OS32C-BP-4M/OS32C-BP-DM-4M + OS32C-BKT1 + OS32C-BKT4 154.7 [6.09] 107.5 [4.24] 103.7 [4.08] 97.7 [3.85] 3-6.4 [0.25] dia. 124.9 [4.92] 4.9 [0.19] 79.2 [3.12] Scan Plane 75.2 [2.96] 24.5 [0.97] 39.9 [1.57] 12.2 [0.48] 50.0 [1.97] 23.3 [0.92] 41.0 [1.62] 4.8 [0.19] Back View 37.9 [1.49] 93.7 [3.69] Side View 155.9 [6.14] 106.0 [4.17] 4-5.3 [0.21] dia. 102.4 [4.03] 144.4 [5.69] 66.4 [2.62] 54.5 [2.15] 23.3 [0.92] Bottom View OS32C with Bottom/Side Mounting Brackets and XY Axis Rotation Mounting Kit OS32C-BP/OS32C-BP-DM/OS32C-BP-4M/OS32C-BP-DM-4M + OS32C-BKT1 + OS32C-BKT2 111. 4 [4.39] 4-5.3 [0.21] dia. 132.7 [5.23] 95.2 [3.75] Scan plane 48.0 [1.89] 99.2 [3.91] 55.9 [2.20] 43.0 15.0° [1.69] 7.5° 28.2 [1.11] 50.0 [1.97] 17.0 [0.67] 93.5 [3.68] 150.5 [5.93] For Y-angular adjustment (x3) slots Use M6 hex head screws, split and flat washers hardware user supplied 46.0 [1.81] Side View Back View (For back mounting) 163.7 [6.45] 119.7 [4.72] R47.5 [1.87] 15.0° 7.5° Hardware for Y-adjustment 166.3 [6.55] 151.1 [5.95] 4-5.3 [0.21] dia. 102.4 [4.03] 163.0 [6.42] 42.2 [1.66] 17.4 [0.69] 2-R72 [2.83] 6.4 [0.25] Back View (For Y-anglular adjustment) 54.5 [2.15] 37.0 [1.46] Bottom View In order to comply with Section 4.2.16 of IEC 61496-3, when the OS32C is mounted where the scanner position could change (e.g. as the result of an impact), additional mechanical means, such as serrated or toothed lock washers, must be employed in the mounting hardware. 12 OS32C OS32C with Bottom/Side Mounting Brackets, XY Axis Rotation Mounting Kit and Top Guard Kit OS32C-BP/OS32C-BP-DM/OS32C-BP-4M/OS32C-BP-DM-4M + OS32C-BKT1 + OC32C-BKT2 + OS32C-BKT4 168.4 [6.63] 111.4 [4.39] 107.5 [4.24] 4-5.3 [0.21] dia. 141.0 [5.55] 99.2 [3.91] 95.2 [3.75] 48.0 [1.89] SCAN PLANE 55.9 [2.20] 7.5° 50.0 [1.97] 17.0 [0.67] 93.5 [3.68] 150.5 [5.93] 28.2 [1.11] 4.8 [0.19] 46.0 [1.81] Side View Back View (For back mounting) For Y-angular adjustment (x3) slots Use M6 hex head screws, split and flat washers hardware user supplied 15.0° 43.0 [1.69] 163.7 [6.45] 119.7 [4.72] R47.5 [1.87] 15.0° 7.5° Hardware for Y-adjustment 166.3 151.1 [6.55] [5.95] 4-5.3 [0.21] dia. 102.4 [4.03] 163.0 [6.42] 42.2 [1.66] 17.4 [0.69] 2-R72 [2.83] 37.0 [1.46] 54.5 [2.15] 6.4 [0.25] Back View (For Y-angular adjustment) Bottom View In order to comply with Section 4.2.16 of IEC 61496-3, when the OS32C is mounted where the scanner position could change (e.g. as the result of an impact), additional mechanical means, such as serrated or toothed lock washers, must be employed in the mounting hardware. OS32C with Bottom/Side Mounting Brackets, XY Axis Rotation Mounting Kit, Mounting Stand and Mounting Stand Hardware Kit OS32C-SP1/OS32C-SP1-DM/OS32C-BP-4M/OS32C-BP-DM-4M + OS32C-BKT1 + OS32C-BKT2 + OS32C-MT + OS32C-HDT 203.2 [8.00] 609.6 [24.00] 637.2 [25.09] 137.2 [5.40] 424.0 [16.69] 355.1 [13.98] 286. 2 [11.27] 209.6 [8.25] 217.3 [8.56] 111.7 [4.40] 165.1 [6.50] 190.5 [7.50] View A 13 A 235.0 [9.25] 250.8 [9.87] OS32C Power Cable OS32C-CBL-@@M L (56) (90) (30) Sizes are as below Name plate Vinyl insulated round cable (diameter max. 10 mm) Black 18-core (conductor section area 0.3 mm2, insulator diameter max. 1.5 mm) Standard length L (See ) Model Number OS32C-CBL-03M L 3m OS32C-CBL-10M OS32C-CBL-20M 10 m 20 m OS32C-CBL-30M 30 m Ethernet Cable OS32C-ECBL-@@M D-coding 3 4 44.7 L 54.7 1 2 Sizes are as below M12 RJ45 Twist tie Vinyl insulated round cable (diameter max 6.5mm) Light Blue 4-core (conductor section area 0.34mm2, insulator diameter max 1.57mm) Standard length L (See ) Model Number OS32C-ECBL-02M L 2m OS32C-ECBL-05M OS32C-ECBL-15M 5m 15 m Safety Precautions Description shown below is only a guideline to choose a safety laser scanner. To use the product properly, you must read the instruction manual that comes with the product. Legislation and Standards 1. Application of an OS32C sensor by itself cannot receive the type approval provided by Article 44-2 of the Labor Safety and Health Law of Japan. It is necessary to apply it as a system. Therefore, when using this product in Japan as a "safety system for presses and shearing machines" as prescribed in Article 42 of the Labor Safety and Health Law, the complete system must receive the type approval. 2. (1) This product is electro-sensitive protective equipment (ESPE) in accordance with European Union (EU) Machinery Directive Annex V, Item 2. (2) This product complies with the following legislation and standards: 1) EU legislation Machinery Directive 2006/42/EC EMC Directive 2014/30/EU RoHS Directive (2011/65/EC) 2) European & EN 61496-1 (Type 3 ESPE) International EN 62061 Standards EN 50178 EN ISO 13849-1 IEC 61496-3 (Type 3 AOPDDR) IEC 61508, Parts 1-7 (SIL-2) EN 60204-1 3) North American Standards: per UL File E241445, US and CUL approvals (CNN: NIPM/NIPM7). • ANSI/UL 508 (Industrial Control Equipment) • ANSI B11.19 • ANSI/RIA R15.06 • NFPA 79 • Code of Federal Regulations CFR29 • IEC 61496-1 (Type 3 ESPE) • IEC 61496-3 (Type 3 AOPDDR) • UL 1998 (Software in Programmable Components) • IEC 61508 (Functional Safety of Electrical/Electronic/ Programmable Electronic Safety-Related Systems) • IEC 61508-3 (Functional Safety of Electrical/Electronic/ Programmable Electronic Safety-Related Systems - Part 3: Software Requirements) • CAN/CSA-C22.2 No. 14 (Industrial Control Equipment) • CAN/CSA-C22.2 No. 0.8 (Safety Functions Incorporating Electronic Technology) 4) JIS standards JIS B 9704-1 JIS B 9704-3 (Type3 ESPE) (3) This product received the following approvals from TÜV Rheinland of the EU. • EC Type-Examination in accordance with the EU Machinery Directive, Type 3 ESPE (IEC61496-1), Type 3 AOPDDR (IEC61496-3) Safety Precautions The Alert symbols and their meanings ensure safe use of the products In order to use the OS32C safely, the precautions listed in this manual are indicated by alert symbols. The descriptions must be followed, failure to follow all precautions and alerts may result in an unsafe installation or operation. The following indictions and symbols are used. WARNING Indicates a potentially hazardous situation which, if not avoided, will result in minor or moderate injury, or may result in serious injury or death. Additionally there may be significant property damage. CAUTION Indicates a potentially hazardous situation which, if not avoided, will result in minor or moderate injury, or there may be property damage. 14 OS32C Meanings of Alert Symbols Installation WARNING Indicates prohibited actions. Indicates mandatory actions. WARNING An OS32C is an electro-sensitive protective equipment designed to guard personnel working around hazardous machinery. Whether a specific machine application and the OS32C system installation complies with safety regulations depends on the proper application, installation, maintenance and operation of the OS32C system. These items are the responsibility of the purchaser, installer and user. User WARNING The administrator is responsible for the selection and training of personnel to properly install, operate, and maintain the machine and its safeguarding systems. An OS32C system should only be installed, verified and maintained by a qualified person. A qualifed person is defined as “an individual who understands, is trained on, and demonstrates competence with the construction, operation or maintenance of the machinery and the hazards involved.” (ANSI/PMMI B155.1-2006) The machine requirements WARNING The main unit must be securely mounted and its cable connectors must be tightly attached. The OS32C must not be mounted behind glass or within a secondary enclosure. Failure to do so will cause a reduction in detection capability, which can cause serious injury or death. A start switch to release interlock must be installed where an operator can observe the monitored/guarded zone as a whole and cannot operate the switch within the hazardous zone. Per the International standard IEC 61496-3, area scanners used in applications where the angle of approach exceeds +/- 30 degrees with respect to the detection plane, must use reference boundary monitoring (RBM) of the detection zone. Make sure to remove any retro-reflector from the field of view of the OS32C when in RBM mode. A protective mechanism must be installed to prevent a hazardous condition in the event of a subsequent machine component failure. The OS32C does not protect against ejected flying material. Severe smoke and particulate matter may degrade the efficiency of an OS32C, causing it to unexpectedly enter a Machine Stop state. Use of mirrors or mirror-like objects in the protection plane must be avoided, as they can hide part of the area to be monitored/guarded. The guarded machine must be able to stop anywhere in its cycle. Do not use an OS32C on a press with a fullrevolution clutch. Additional guarding may be required to prohibit access to dangerous areas not covered by the OS32C system. The guarded machine must have a consistent stopping time and adequate control mechanisms. Perform the test procedure in this document at installation, after maintenance, adjustment, repair or modification to the machine controls, tooling or the OS32C system. Refer to OS32C Series User’s Manual (Man.No.Z296-E1). All safety-related machine control elements must be designed so that an alarm in the control logic or failure of the control circuit does not lead to a failure to danger. Do not use the auxiliary output or warning output for safety applications. A human body may not be detected even if a failure of OS32C occurrs, resulting in serious injuries. Perform only the test and repair procedures outlined in this manual. Additional measurement error resulting from reflective backgrounds may need to be added to the measurement error of the OS32C. To use the protective function of the OS32C, a safety zone must be properly defined and configured. 15 OS32C If the response time is changed, re-calculation of the safety distance is required. This may require reconfiguration of the safety zones or re-installation of the OS32C. If the safety distance is not appropriate for the application, the machine may not stop before contact with the hazardous part, resulting in serious injuries or death. Wiring connections The activation of RBM Only mode will increase the response time. This additional time must be taken into consideration when calculating the safety guarding distance. For the OS32C to meet IEC 61496-1 and UL 508, its DC power supply unit must satisfy all of the following conditions: • Within rated line voltage (24 VDC +25% / -30%) • Complying with EMC directives (industrial environments) • Double-insulation or reinforced insulation between primary and secondary circuits • Automatic return for overcurrent protection • Output retention time of 20 ms or longer • Satisfying output characteristics requirements of Class 2 circuit or limited voltage/current circuit defined in UL508. • Power supply complying with regulations and standards of EMC and safety of electrical equipment in a country or a region where OS32C is used. (Example: In EU, a power supply must comply with EMC directives and the Low Voltage Directive) When using more than one OS32C, mutual interference should be prevented. This may require different scanner positions or physical shields to be installed. To ensure a protection degree of IP65, DO NOT use this product without proper sealing of the cable connector, I/O block, and scan window. If the external zone switching device momentarily exceeds the configured number of active zone set select inputs during the zone switch, an additional Zone Delay may be incurred in the event that wiring of a zone set select input fails. The external zone switching device must properly sequence so the configured number of active inputs is not exceeded in order to guarantee that failed zone set select input wiring will be detected within the normal Zone Switching Time described below. If an insufficient Zone Delay is used for the actual worst case switching time of the installation, the scanner might start monitoring the wrong zone during the switching period. Also, if an insufficient Zone Delay is used for the actual worst case switching time of the installation, there might be a fault condition during the zone switching period. If tstart (switching start time) is configured without consideration of TmaxReaction (total maximum reaction time), object detection within the new safety zone after switching and turning OFF of the safety outputs may be delayed. Monitoring zone parameters are subject to a number of constraints that include projective consistency, maximum radius, and angle limits. As a result, an imported zone may not correspond exactly to the zone defined in the file. The user must visually verify the imported zone when the zone coordinate import process is complete. Refer to Checkout and Test Procedure Log on OS32C Series User’s Manual (Man.No.Z296-E1) The installer is responsible for assessing the risk and to ensure that the zone of limited detection does not create a safety hazard. If a hazard exists additional countermeasure must be taken, this may require additional guarding measures. WARNING Do not connect the OS32C to a power supply with more than 24VDC + 25% / -30%. Do not supply AC power to the OS32C, this may result in electrical shock. To prevent electrical shock, use double-insulation or reinforced insulation from hazardous voltage (such as 230 VAC). Cable extensions must be within the specified lengths, otherwise it may result in a failure of the safety functions. To use this product for a category 3 safety system, both safety outputs must be connected to the safety system. Configuring a safety system with only one safety output may result in serious injuries due to output circuit fault and a failure of the machine to stop. Protection of Cable at Installation: Care should be taken when installing the OS32C cable. The cable must be properly routed and secured to ensure that damage does not occur. Functional Earth: The OS32C system requires a functional earth connection. Do not connect Functional Earth to a positive ground system. If it is connected to positive ground, the guarded machine to be controlled may NOT stop, resulting in severe operator injury. Signal Connector Isolation: The connectors used during installation must provide sufficient signal separation in order to prevent a short circuit condition of the input power and system signals. CAUTION When wiring the OS32C to external devices, make sure to follow the color and coding schemes per EN 60204-1. 16 OS32C Others WARNING Do not modify the main unit of the OS32C. Do not replace or fix any component of the OS32C other than the ones specified in this manual. Doing so may result in a failure of this device to function correctly. If there is any damage to the window, replace them as soon as possible. Otherwise it may result in a failure of the OS32C. Take preventive measures when performing replacement work so that dust does not enter the OS32C. Always detach all cables from the OS32C before replacing the scan window. Otherwise the motor may start rotating, resulting in injuries. The window replacement procedure must only be performed by qualified personnel in a clean environment at ambient temperature (5 to 35 °C) to prevent the internal optical surface from contamination. Make sure the inside and the outside of the replacement window is clean and free from scratch, dust, and finger print. The calibration procedure must only be performed by qualified personnel. Before performing window calibration of the new scan window, make sure the window is clean and free from scratch, dust, and finger print. The window calibration procedure must be performed at ambient temperature 5 to 35 °C. Failure to inspect the window or set the proper environmental condition during window calibration procedure may cause a reduction in the detection capability of the scanner. The tests outlined in this Test Procedure (Refer to OS32C Series User’s Manual (Man.No.Z296-E1) ) must be performed at time of installation, according to the employer's regular inspection program and after any maintenance, tooling change, set up, adjustment, or modification to the OS32C system or the guarded machine. Where a guarded machine is used by multiple operators or shifts, it is suggested that the test procedure be performed at each shift or operation change and also if there is a change in the OS32C operating mode or defined zone sets. Testing ensures that the safety laser scanner and the machine control system are working properly to stop the machine. Failure to test properly could result in serious injury to personnel. If the OS32C is operated under automatic start, make sure that the machine stops and does not restart as long as an object is detected in a safety zone. Check the operation by placing a test piece into the safety zone. It is recommended to perform the test at least after a shift change or 24 hours of operation. If the safety system or the machine fails any of these tests, do not run the machine. Immediately tag or lock out the machine to prevent its use and notify the appropriate supervisor. 17 System and zone status parameters monitored over EtherNet/IP are to be used for diagnostic purposes only, and must not be used in safety-critical functions. Measurement data monitored over EtherNet/IP are to be used for diagnostic purposes only, and must not be used in safety-critical functions. CAUTION When transferring data from the PC to the OS32C and more than one OS32C is connected to the network, it is necessary to visually check the diagnostic code on the status/diagnostic display. It is recommended that the OS32C be installed in a position where the status/diagnostic display will be visible. Before sending the changes to the sensor, verify that the safety parameters are configured as intended for the application. Take precautions to prevent dirt, dust or debris from entering the sensor and I/O block connectors. It is recommended that this be done on a clean workstation as contaminants may degrade the performance of the OS32C. Adhesion of dust to the scan window may cause a false operation. The OS32C will require periodic cleaning of the scan window and dust detection surface. Operation of the OS32C may be affected by light in the environment, such as incandescent light, strobe light and light from a photosensor using infrared light. Operation of the OS32C may be affected by substances in the environment, such as fog, smoke, steam and other small particles. Ensure the measurement report configuration matches the expected measurement data format. OS32C Configuration Tool Features and Compatibility Refer to the table below for supported features and compatibility with OS32C versions. Refer to the product labels to determine the OS32C version. NOTE: • Only the version of the sensor block and the configuration tool were updated to support the new features. No changes were made to the I/O block. • The window replacement kit OS32C-WIN-KT can be used on any sensor block. The part numbers The part numbers have changed: OS32C-SN: 40591-0010 (old), 40591-0020 (current) OS32C-SN-DM: 40591-0040 (current) OS32C-SN-4M: 40603-0020 (current) OS32C-SN-DM-4M: 40603-0040 (current) OS32C Version ✓: Supported OS32C-DM OS32C-4M OS32C-DM-4M 40591-0010 40591-0020 40591-0040 40603-0020 40603-0040 Configurable minimum object resolution -- ✓ ✓ ✓ ✓ Standby mode with laser shutoff -- ✓ ✓ ✓ ✓ Copy & paste zones and zone sets -- ✓ ✓ ✓ ✓ Record system monitoring -- ✓ ✓ ✓ ✓ Playback system monitoring -- ✓ ✓ ✓ ✓ Support for inverting 7-segment display -- ✓ ✓ ✓ ✓ Display configuration filename in config tool header -- ✓ ✓ ✓ ✓ Additional zone shapes (180° semi-circle, 180° rectangle, 180° polygon) -- ✓ ✓ ✓ ✓ Config tool support for switching between default OS32C configuration and the user's current working configuration -- ✓ ✓ ✓ ✓ Troubleshooting tips displayed in fault log -- ✓ ✓ ✓ ✓ Configuration checksum, safety checksum 3 *1 3 *1 3 *1 3 *1 3 *1 -- ✓ ✓ ✓ ✓ Non-safety checksum 3 *2 3 *2 3 *2 3 *2 3 *2 Single Import & Export Zone Coordinate Data 3 *2 3 *2 3 *2 3 *2 3 *2 -- 3 *3 3 *2 3 *2 3 *2 3 *4 3 *4 3 *4 3 *4 3 *4 Windows 7 support Maintenance access level Rotation of monitor screen view French, German, Italian & Spanish Languages 3 *4 3 *4 3 *4 3 *4 3 *4 Multiple Import & Export Zone Coordinate Data 3 *4 3 *4 3 *4 3 *4 3 *4 EtherNet/IP and Measurement Data -- -- 3 -- 3 Pollution Tolerance Mode -- 3 *6 3 *6 3 *5 3 *5 Variable response time settings -- 3 *6 3 *6 3 *5 3 *5 4 meter safety/ 15 meter warning zone -- -- -- 3 *5 3 *5 Status information during monitor mode -- 3 *6 3 *6 3 *5 3 *5 Confirmation of Safety parameters -- 3 *6 3 *6 3 *5 3 *5 Warning Zone changed via Ethernet/IP capability -- -- 3 *6 -- 3 *5 Windows 10 support -- 3 *7 3 *7 3 *7 3 *7 18 OS32C *1. Requires Configuration Tool Version 1.4.0 and up *2. Requires Configuration Tool Version 1.6.0 and up *3. If serial number of the sensor block is higher than AS08300 and Configuration Tool is version 1.6.0 and up *4. Requires Configuration Tool is Version 1.8.0 and up *5. Requires Configuration Tool is Version 2.0.0 and up *6. If serial number of the sensor block is higher than AS17500 and Configuration Tool is Version 2.0.0 and up *7. Requires Configuration Tool Version 2.2.8 and up Configuration Tool Version ✓: Supported before 1.4.0 1.4.0 and up 1.6.0 and up 1.8.0 and up 2.0.0 and up 2.2.8 and up Configurable minimum object resolution -- ✓ ✓ ✓ ✓ ✓ Standby mode with laser shutoff -- ✓ ✓ ✓ ✓ ✓ Copy & paste zones and zone sets -- ✓ ✓ ✓ ✓ ✓ Record system monitoring -- ✓ ✓ ✓ ✓ ✓ Playback system monitoring -- ✓ ✓ ✓ ✓ ✓ Support for inverting 7-segment display -- ✓ ✓ ✓ ✓ ✓ Display configuration filename in config tool header -- ✓ ✓ ✓ ✓ ✓ Additional zone shapes (180° semi-circle, 180° rectangle, 180° polygon) -- ✓ ✓ ✓ ✓ ✓ Config tool support for switching between default OS32C configuration and the user's current working configuration -- ✓ ✓ ✓ ✓ ✓ Troubleshooting tips displayed in fault log -- ✓ ✓ ✓ ✓ ✓ Configuration checksum, safety checksum -- ✓ ✓ ✓ ✓ ✓ Windows 7 support -- ✓ ✓ ✓ ✓ ✓ Non-safety checksum -- -- ✓ ✓ ✓ ✓ Single Import & Export Zone Coordinate Data -- -- ✓ ✓ ✓ ✓ Maintenance access level -- -- ✓ ✓ ✓ ✓ Rotation of monitor screen view -- -- -- ✓ ✓ ✓ French, German, Italian & Spanish Languages -- -- -- ✓ ✓ ✓ Multiple Import & Export Zones Coordinate Data -- -- -- ✓ ✓ ✓ Pollution Tolerance Modes -- -- -- -- ✓ ✓ Variable response time settings -- -- -- -- ✓ ✓ 4 meter safety/ 15 meter warning zone -- -- -- -- ✓ ✓ Status information during monitor mode -- -- -- -- ✓ ✓ Confirmation of Safety parameters -- -- -- -- ✓ ✓ Warning Zone changed via Ethernet/IP capability -- -- -- -- ✓ ✓ Windows 10 support -- -- -- -- -- ✓ Note: The configuration data file extension is *.cf2 until Configuration Tool Version 1.8.0 and *.cf3 from Version 2.0.0. ✓: Supported Model 19 Sensor Head P/N Configuration Tool Version before 1.4.0 1.4.0 and up 1.6.0 and up 1.8.0 and up 2.0.0 and up OS32C-SN 40591-0010 ✓ ✓ ✓ ✓ ✓ OS32C-SN 40591-0020 -- ✓ ✓ ✓ ✓ OS32C-SN-DM 40591-0040 -- -- ✓ ✓ ✓ OS32C-SN-4M 40603-0020 -- -- -- -- ✓ OS32C-SN-DM-4M 40603-0040 -- -- -- -- ✓ OMRON AUTOMATION AMERICAS HEADQUARTERS • Chicago, IL USA • 847.843.7900 • 800.556.6766 • automation.omron.com OMRON CANADA, INC. • HEAD OFFICE Toronto, ON, Canada • 416.286.6465 • 866.986.6766 • automation.omron.com OMRON ELETRÔNICA DO BRASIL LTDA • HEAD OFFICE São Paulo, SP, Brasil • 55.11.2101.6300 • www.omron.com.br OMRON ELECTRONICS DE MEXICO • HEAD OFFICE Ciudad de México • 52.55.5901.4300 • 01.800.386.6766 • mela@omron.com OMRON ARGENTINA • SALES OFFICE Buenos Aires, Argentina • +54.11.4521.8630 • +54.11.4523.8483 mela@omron.com OMRON ELECTRONICS DE MEXICO • SALES OFFICE San Pedro Garza García, N.L. • 81.12.53.7392 • 01.800.386.6766 • mela@omron. com OTHER OMRON LATIN AMERICA SALES +54.11.4521.8630 • +54.11.4523.8483 • mela@omron.com OMRON ELECTRONICS DE MEXICO • SALES OFFICE Eugenio Garza Sada,León, Gto • 01.800.386.6766 • mela@omron.com Controllers & I/O • Machine Automation Controllers (MAC) • Motion Controllers • Programmable Logic Controllers (PLC) • Temperature Controllers • Remote I/O Authorized Distributor: Robotics • Industrial Robots • Mobile Robots Operator Interfaces • Human Machine Interface (HMI) Motion & Drives • Machine Automation Controllers (MAC) • Motion Controllers • Servo Systems • Frequency Inverters Vision, Measurement & Identification • Vision Sensors & Systems • Measurement Sensors • Auto Identification Systems Sensing • Photoelectric Sensors • Fiber-Optic Sensors • Proximity Sensors • Rotary Encoders • Ultrasonic Sensors Safety • Safety Light Curtains • Safety Laser Scanners • Programmable Safety Systems • Safety Mats and Edges • Safety Door Switches • Emergency Stop Devices • Safety Switches & Operator Controls • Safety Monitoring/Force-guided Relays Control Components • Power Supplies • Timers • Counters • Programmable Relays • Digital Panel Meters • Monitoring Products Switches & Relays • Limit Switches • Pushbutton Switches • Electromechanical Relays • Solid State Relays Software • Programming & Configuration • Runtime Z298I-E3-04 Note: Specifications are subject to change. © 2019 Omron. All Rights Reserved. Printed on recycled paper. Printed in U.S.A.
OS32C-WIN-KT 价格&库存

很抱歉,暂时无法提供与“OS32C-WIN-KT”相匹配的价格&库存,您可以联系我们找货

免费人工找货