OMRON
®
OMRON NETWORK PRODUCTS
1.0
Description
The P1RX4C-SX4x-01MM (SX4 ROSA Module) is an
optical to electrical (O-E) module that receives four
video- or data-channels from one singlemode or
multimode fiber. With the TIA and Limiting Amp
embedded in the OSA and enclosed in an EMI shielded
metal housing, the SX4 ROSA module is a fully
integrated receiver versatile enough to be designed in to
a variety of systems.
2.0
Features
•
•
•
•
Multiple signals from one Multimode fiber
Integrated TIA and Limiting Amp
Metal enclosure with SC optical interface
CML outputs
This device is EXTREMELY SENSITIVE to Electrostatic Discharge (ESD). At a minimum, all handling must be
performed in accordance with an ANSI-compliant ESD Control Program (ANSI/ESD S20.20-2007) to mitigate
possible ESD-induced damage. Reliability and life of the device will be adversely affected if these precautions are
not met.
This device is a Class 3R Laser device (per IEC 60825-1:2007) and can cause damage to eye sight if used improperly. Refer to ANSI
Z136 for proper handling and usage of Class 3R devices.
ORIGINATOR:
OMRON
C. ENG
Date:
P1RX4C-SX4x-01MM Product Specification
7/8/2011
DOCUMENT NO.
REV
DOC002107
A
SHEET 1 OF 6
OMRON
®
OMRON NETWORK PRODUCTS
3.0
Absolute Maximum Ratings
Parameter
Symbol
Min
Tst
VCC1
Ta
RH
-40
-0.3
0
1, 3
Storage Temperature
3.3V Supply Voltage
2
Operating Surface Temperature
3
Operating Humidity
Durability – SC Connector
Durability – Plug-down Connector
4.0
Typ
Max
Units
85
3.6
65
80
°C
V
°C
200
50
%
cycles
cycles
Optical Characteristics
Parameter (per channel) Symbol Min
Typ
Max
Units
Wavelength – Lane 0
778
nm
Wavelength – Lane 1
800
nm
Wavelength – Lane 2
825
nm
Wavelength – Lane 3
4
Data Rate per Channel
P1RX4C-SX4V-01
P1RX4C-SX4D-01
850
nm
DR
1.65
3.50
Gb/s
Peak Optical Input Power
Pin
4.0
dBm
5
OMA Sensitivity
-14.25
-16.00
dBm
1
Stresses listed may be applied without causing damage. Functionality at or above the values listed is not implied. Exposure to these
values for extended periods may affect reliability.
See outline drawing for measurement point.
3
Non condensing, 80% RH.
4
Requires DC-balanced data pattern and max run rate of 80 bits. Measured with input signals conforming to HDMI rev 1.3a, section
4.2.5, figure 4-20.
5
Optical Modulation Amplitude. Based on an unstressed input signal.
2
ORIGINATOR:
OMRON
C. ENG
DATE:
P1RX4C-SX4x-01MM Product Specification
7/8/2011
DOCUMENT NO.
REV
DOC002107
A
SHEET 2 OF 6
OMRON
®
OMRON NETWORK PRODUCTS
5.0
Electrical Specifications
Parameter
Symbol
Low Frequency Cutoff
Min
Typ
FCUTOFF
6
Total Jitter (RMS), per lane
Max
175
Units
kHz
TJ1
10
ps
VOD
500
mVp-p
LOSSEN-ON
-14.50
dBm
Loss of Signal De-Assert Sensitivity LOSSEN-OFF
-13.00
dBm
7
Differential Output Voltage
Loss of Signal Assert Sensitivity
8
VLOS
Loss of Signal Output High
VLOS
2
Operating Supply Voltage
VCC
3.15
Operating Supply Current
ICC
Loss of Signal Output Low
0.7
V
V
3.30
127
3.54
V
mA
6
Based on a jitter-free source
CML interface through a 100-ohm differential load.
8
This output is asserted low when a loss of signal is detected on all Lanes
7
ORIGINATOR:
OMRON
C. ENG
DATE:
P1RX4C-SX4x-01MM Product Specification
7/8/2011
DOCUMENT NO.
REV
DOC002107
A
SHEET 3 OF 6
OMRON
®
OMRON NETWORK PRODUCTS
6.0
Pin Numbers and Descriptions
The RX-SX4 plugs into a 30 pin connector. For information on the specifications
of the connector, contact Hirose (DF12(4.0)-30DP-0.5V(86)).
7.0
Pin #
Signal
Description
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
GND
LOS
+TD0
NC
-TD0
NC
+TD1
NC
-TD1
NC
+TD2
NC
-TD2
NC
+TD3
NC
-TD3
NC
GND
NC
NC
NC
NC
NC
NC
NC
NC
VCC
GND
VCC
Ground
Global Loss of Signal Indicator
Positive Data Output (778nm)
No Connect9
Negative Data Output (778nm)
No Connect9
Positive Data Output (800nm)
No Connect9
Negative Data Output (800nm)
No Connect9
Positive Data Output (825nm)
No Connect9
Negative Data Output (825nm)
No Connect9
Positive Data Output (850nm)
No Connect9
Negative Data Output (850nm)
No Connect9
Ground
No Connect9
No Connect9
No Connect9
No Connect9
No Connect9
No Connect9
No Connect9
No Connect9
3.3 volt input.
Ground
3.3 volt input.
Laser Safety
The P1RX4-SX4x-01 meets Class-3 requirements.
9
NC = No Connect. Do not connect anything to this pin.
ORIGINATOR:
OMRON
C. ENG
DATE:
P1RX4C-SX4x-01MM Product Specification
7/8/2011
DOCUMENT NO.
REV
DOC002107
A
SHEET 4 OF 6
OMRON
®
OMRON NETWORK PRODUCTS
8.0
Environmental Standards
Omron Network Products designs and manufactures its products to minimize the
negative impact on our environment. As such, the P1RX4C-SX4-01MM
conforms to a variety of environmental and safety standards
Standard
RoHS
ORIGINATOR:
OMRON
C. ENG
Compliant
Yes
DATE:
P1RX4C-SX4x-01MM Product Specification
Certificate Available
Yes
7/8/2011
DOCUMENT NO.
REV
DOC002107
A
SHEET 5 OF 6
OMRON
®
OMRON NETWORK PRODUCTS
Dimensions
The SX4 ROSA is designed to work with a standard SC ferrule only. Insertion of
any other type may result in damage.
Dimensions (mm) and orientation are for reference only.
Temperature measurement point
ORIGINATOR:
OMRON
C. ENG
DATE:
P1RX4C-SX4x-01MM Product Specification
7/8/2011
DOCUMENT NO.
REV
DOC002107
A
SHEET 6 OF 6
P1RX4C-SX4V-01MM-DC 价格&库存