PYDN-6.2-020R

PYDN-6.2-020R

  • 厂商:

    OMRON(欧姆龙)

  • 封装:

    -

  • 描述:

    继电器插座及配件 2Pin 红色 P=6.2mm 32A

  • 数据手册
  • 价格&库存
PYDN-6.2-020R 数据手册
Slim I/O Relays Global standard size, low profile slim (6.2 mm width) I/O relays G2RV-SR: G3RV-SR: • 25% lower profile than conventional products, contributing to a smaller control panel. • Push-In Plus terminal blocks reduce wiring work by 60%* compared to conventional screw terminals. • ‘Hand-free’ structure that holds an inserted flat-blade screwdriver to achieve easier wiring work for stranded wires. G3RV-SR • Electromechanical relays (G2RV-SR) and solid state relays (G3RV-SR) are available. • Screw terminal terminal block models are available. • Plug-in terminal has strong mechanical pins that do not bend. * According to OMRON actual measurement data from November 2015. G2RV-SR G2RV-SR/G3RV-SR For the recent information on models that have been certified for safety standards, refer to your OMRON website. Slim I/O Relay Types G2RV-SR series mounted relay: electromagnetic relay ...... from page 2 G3RV-SR series mounted relay: solid state relay ................ from page 10 Common matter Common Precautions Refer to Safety Precautions on page 20. Common precautions ................................................................ from page 20 Common accessories (order separately)................................. page 24 Common Accessories 1 Slim Electromechanical I/O Relay G2RV-SR G2RV-SR Global standard size, low profile, slim (6.2 mm width) I/O relay G3RV-SR • 25% lower profile than conventional products, contributing to a smaller control panel. • Opening and closing ability with one pole 6 A slim shape. • Micro load products for one pole 50 mA using gold-plated contacts for small load switching also available. • Since G2RV has a transparent case, confirming the state of the contact with the naked eye is possible. • Screw terminal terminal block models are available. • Plug-in type terminal has strong mechanical pins that do not bend. For the recent information on models that have been certified for safety standards, refer to your OMRON website. Refer to Safety Precautions on page 20. Common Precautions Common Accessories 2 Features With latching lever (Test switch) Standard model/Micro load Terminal x 5 • Push-in • Screw Release lever Mechanical indicator • Operation verification which is linked to the contact Operation display LED (Socket section) Push-In Plus Terminal Block Protective cover (Released state) Protective cover (Locked condition) Latching lever (Test switch) Latching lever (Test switch) • Circuit check operation Confirmation, reducing the inspection effort PAT "Foreign matter intrusion prevention structure" "Malfunction prevention stopper" Transparent case Relay contact Easy confirmation of the situation Release lever Relay easily fixed/removed 90 mm 80 mm Plug-in terminal Terminal has strong mechanical pins that do not bend. Short bar insertion holes Release hole Terminal (insertion) hole G2RV-SR Model Number Structure Model Number Legend (1) (2) (3) (4) (5) (6) (1) Basic model name G2RV: Slim I/O Relay (2) Sub type SR: Slim relay + integrated low profile socket (3) Terminal (wire connection) 50: Push-In Plus Terminal 70: Screw terminal (5) Contact structure Blank: Standard AP: Microloads (4) Latching lever (test switch) 0: Without latching lever 1: With latching lever (6) Rated input voltage 12, 24 VDC 24, 48 VAC/VC 100, 110, 200, 230 VAC G2RV-SR G2RV-SR @@ @ - @ @ Ordering Information Terminal (Wire connection) Latching lever (Test switch) Classification Rated input voltage (V) AC/DC G2RV-SR500 AC200 230 G2RV-SR500 AC230 DC 24 G2RV-SR501 DC24 AC/DC 24 G2RV-SR501 AC/DC24 12 G2RV-SR500-AP DC12 24 G2RV-SR500-AP DC24 24 G2RV-SR500-AP AC/DC24 48 G2RV-SR500-AP AC/DC48 100 G2RV-SR500-AP AC100 110 G2RV-SR500-AP AC110 200 G2RV-SR500-AP AC200 230 G2RV-SR500-AP AC230 12 G2RV-SR700 DC12 24 G2RV-SR700 DC24 24 G2RV-SR700 AC/DC24 48 G2RV-SR700 AC/DC48 100 G2RV-SR700 AC100 110 G2RV-SR700 AC110 200 G2RV-SR700 AC200 230 G2RV-SR700 AC230 DC 24 G2RV-SR701 DC24 AC/DC 24 G2RV-SR701 AC/DC24 12 G2RV-SR700-AP DC12 No AC DC AC/DC No Standard AC DC AC/DC Microloads No AC 24 G2RV-SR700-AP DC24 24 G2RV-SR700-AP AC/DC24 48 G2RV-SR700-AP AC/DC48 100 G2RV-SR700-AP AC100 110 G2RV-SR700-AP AC110 200 G2RV-SR700-AP AC200 230 G2RV-SR700-AP AC230 Note: Solid wire cannot be used for Push-In Plus terminal type. Make sure to use stranded wire or stranded wire with ferrules. Common Accessories G2RV-SR500 AC110 200 Common Precautions 110 AC/DC Yes G2RV-SR500 AC/DC24 G2RV-SR500 AC/DC48 DC Screw terminal 24 G2RV-SR500 AC100 AC Microloads G2RV-SR500 DC24 100 Standard Yes G2RV-SR500 DC12 24 48 No Push-In Plus Terminal 12 G3RV-SR DC Model 3 G2RV-SR Relay for Maintenance G2RV-SR Model Number Legend G2RV-1 - S @ - @ - G @ (1) (2) (3) (4) (5) (1) No. of poles 1: 1 pole G2RV-1-SI-G G2RV-1-S-G(-AP) (6) (4) Contact material Blank: Silver alloy AP: Silver alloy + gold plate (2) Terminal S: plug-in (3) Latching lever (Test switch) Blank: Without latching lever I: With latching lever (5) Types of relay for exchange G: G2RV-SR series equipped Relay (6) Rated coil voltage Number: 11, 21, 48 VDC List of Models G3RV-SR Type Latching Lever (Test switch) No Rated coil voltage (V) Model 11 G2RV-1-S-G DC11 21 G2RV-1-S-G DC21 G2RV-SR700/500 DC12V G2RV-SR700/500 DC24V G2RV-SR700/500 AC/DC24V G2RV-SR700/500 AC/DC48V DC Standard Applicable model G2RV-SR700/500 AC100V 48 G2RV-1-S-G DC48 G2RV-SR700/500 AC110V G2RV-SR700/500 AC200V G2RV-SR700/500 AC230V Common Precautions Common Accessories 4 Yes Microload No DC 21 G2RV-1-SI-G DC21 11 G2RV-1-S-AP-G DC11 21 G2RV-1-S-AP-G DC21 G2RV-SR701/501 DC24V G2RV-SR701/501 AC/DC24V G2RV-SR700/500-AP DC12V G2RV-SR700/500-AP DC24V G2RV-SR700/500-AP AC/DC24V G2RV-SR700/500-AP AC/DC48V DC G2RV-SR700/500-AP AC100V 48 G2RV-1-S-AP-G DC48 G2RV-SR700/500-AP AC110V G2RV-SR700/500-AP AC200V G2RV-SR700/500-AP AC230V G2RV-SR Specifications Ratings Operation voltage Rated current Rated input voltage AC 50 Hz DC 60 Hz 12 VDC – – – Release voltage Percentage of the rated voltage 27.2 mA Power consumption Maximum allowable voltage AC (VA) Percentage of the rated voltage DC (mW) – Approx. 300 mW Approx. 300 mW 24 VDC – 13.3 mA – 24 VAC/VDC 21.1 mA 22.5 mA 13.0 mA Approx. 0.5 VA Approx. 300 mW 48 VAC/VDC 8.5 mA 9.0 mA 5.2 mA 100 VAC 7.1 mA 7.5 mA – 110 VAC 7.1 mA 7.5 mA – Approx. 0.8 VA – 200 VAC 7.2 mA 7.9 mA – Approx. 1.7 VA – 230 VAC 7.3 mA 7.9 mA – Approx. 1.7 VA – 80% max.* Approx. 0.4 VA Approx. 250 mW 10% min. Approx. 0.8 VA – 110% Contact ratings Item Standard (G2RV-SR700, 500, 701, 501) For microloads (G2RV-SR700-AP, 500-AP) *2 SPDT Load Resistive load (cosφ=1) Inductive load (cosφ=0.4, L/R=7ms) Resistive load (cosφ=1) Rated load 6 A at 250 VAC 6 A at 30 VDC 2.5 A at 250 VAC 2 A at 30 VDC 50 mA at 30 VAC 50 mA at 36 VDC Rated carry current 6A 50 mA Maximum switching voltage 440 VAC, 125 VDC 30 VAC, 36 VDC Maximum switching current 6A Maximum switching power 1,500 VA 180 W Failure rate P value (reference value) *1 10 mA at 5 VDC 50 mA – 1 mA at 100 mVDC *1. P level: λ60=0.1×10 /times This value is the value in switching frequency 120 operations/min. *2. If the gold plating layer is destroyed, the number will be the same as the standard type. Characteristics Standard (G2RV-SR700, 500, 701, 501) For microloads (G2RV-SR700-AP, 500-AP) 100 mΩ max. Operate (Set) time * 20 ms max. Release time * AC, AC/DC: 40 ms max. DC: 20 ms max. Maximum operating frequency Mechanical: 18,000 operations/h Electrical: 1,800 operations/h (rated load) Insulation resistance 1,000 MΩ min. (at 500 VDC) Dielectric strength Between coil and contacts: 4,000VAC 50/60 Hz 1 min Contact between the same polarity: 1,000 VAC 50/60 Hz 1 min Vibration resistance Destruction: 10 to 55 to 10 Hz, single amplitude 0.50 mm (double amplitude 1.0 mm) Malfunction: 10 to 55 to 10 Hz, single amplitude 0.50 mm (double amplitude 1.0 mm) Shock resistance Destruction: 1,000 m/s2 Malfunction: Energized 200m/s2, Non-energized 100m/s2 Endurance * Mechanical 5,000,000 operations min. Electrical NO contact: 70,000 operations min. NC contact: 50,000 operations min. 5,000,000 operations min. Ambient operating temperature Operating: –40 to +55°C (with no icing or condensation) Ambient operating humidity Operating: 5 to 85% RH Weight Approx. 30 g Contact material Ag alloy Common Accessories Contact resistance * Common Precautions 500 VA 60 W -6 Item G3RV-SR Note: The operating characteristics are measured at ambient temperature of 23°C. * Operating voltage will be 85% max. for upside down mounting. Contact configuration G2RV-SR Coil ratings Ag alloy + Au plating Note: Above values are initial values. * Value is at ambient temperature of 23°C. 5 G2RV-SR Approved standards G2RV-SR UL508 (file No.E41643) Model No. of poles G2RV-SR series Operation coil ratings 12 to 48 VDC 24 to 230 VAC SPDT Contact ratings Operations 6 A at 250 VAC (Resistive load) 6 A at 30 VDC (Resistive load) 6,000 2 A at 400 VAC (Resistive load)* * If the load voltage exceeds 250 VAC, please attach with a spacing of 12 mm min., or use a separate plate (XW5Z-EP12). 12 mm 12 mm 12 mm G3RV-SR VDE (EN 61810-1) Model No. of poles G2RV-SR series Operation coil ratings 12, 24 VDC 24, 48 VAC/VDC 100, 110, 200, 230 VAC SPDT Contact ratings Operations 6 A at 250 VAC (Resistive load) 50,000 6 A at 30 VDC (Resistive load) 50,000 2 A at 400 VAC (Resistive 6,000 load)* * If the load voltage exceeds 250 VAC, please attach with a spacing of 12 mm min., or use a separate plate (XW5Z-EP12). 12 mm 12 mm 12 mm Switching capacity of DC resistive load 1000 30 VDC resistive load 250 VAC resistive load DC breaking current (A) Endurance curve (N.O. side) Common Accessories Number of operations (x 103 operations) Common Precautions 6 Engineering Data 10.0 1.0 100 30 VDC resistive load 250 VAC resistive load 10 0 0.1 2 4 6 Opening and closing current (A) 20 60 100 140 180 220 DC switching voltage (V) G2RV-SR Dimensions (unit: mm) Slim I/O Relay + socket Push-In Plus Terminal Block Terminal Arrangement/Internal Connection Diagram (TOP VIEW) 12 VDC Input circuit A1 G2RV-SR Models without latching lever (without test switch) G2RV-SR500 78 max. G2RV-SR500-AP A2 G2RV 3.4 74.5 65.89 Other voltage 35.25 18.78 (5.05) Input circuit A1 G2RV 12 A2 14 11 78.77 G3RV-SR 90 max. 35.3 24 VDC Input circuit 12 A1 14 A2 G2RV 11 * : Diode bridge (5.05) : Light emitting diode 18.78 6.2 max. 35.25 51.72 59.71 12 14 Models with latching lever (with test switch) G2RV-SR501 Terminal Arrangement/Internal Connection Diagram (TOP VIEW) 12 VDC 81 max. Input circuit A1 A2 G2RV 3.4 (5.05) 77.5 65.89 Other voltage 35.25 18.78 Input circuit A1 G2RV 12 A2 11 78.77 24 VDC 90 max. Input circuit A1 12 14 A2 G2RV 11 * (5.05) : Diode bridge : Light emitting diode 18.78 6.2 max. 35.25 51.72 59.71 12 Common Accessories 14 35.3 Common Precautions 11 14 11 7 G2RV-SR Screw terminal G2RV-SR Models without latching lever (without test switch) G2RV-SR700 G2RV-SR700-AP Terminal Arrangement/Internal Connection Diagram (TOP VIEW) 12 VDC Input circuit 78 max. A1 G2RV 3.4 A2 74.5 Other voltage 65.89 35.18 Input circuit 18.71 (5.05) A1 G2RV 12 A2 14 11 78.77 35.3 90 max. G3RV-SR 24 VDC Input circuit 12 A1 14 A2 G2RV 11 * (5.05) 18.71 : Diode bridge : Light emitting diode 35.18 6.2 max. 51.65 56.2 12 14 Common Precautions 11 Models with latching lever (with test switch) G2RV-SR701 Terminal Arrangement/Internal Connection Diagram (TOP VIEW) 12 VDC Input circuit 81 max. A1 G2RV 3.4 A2 77.5 Other voltage 65.89 35.18 (5.05) Input circuit 18.71 A1 G2RV 12 A2 14 Common Accessories 11 78.77 35.3 24 VDC 90 max. Input circuit 14 A2 G2RV 11 * (5.05) 18.71 : Diode bridge : Light emitting diode 35.18 6.2 max. 51.65 56.2 12 14 11 8 12 A1 G2RV-SR Relay for maintenance 5.2 max. G2RV-SR Models without latching lever G2RV-1-S-G G2RV-1-S-AP-G 30.5 max. Terminal Arrangement/ Internal Connection Diagram (TOP VIEW) 33 max. 16.2 0.5 14 11 12 A1 A2 G3RV-SR 1.8 (Input circuit) 2.4 3.5 5.04 5.04 22 3 Models with latching lever (test switch) G2RV-1-SI-G 30.5 max. Terminal Arrangement/ Internal Connection Diagram (TOP VIEW) (Input circuit) 36 max. 14 11 12 16.2 1.8 A1 A2 Common Precautions 5.2 max. 0.5 2.4 5.04 5.04 22 3 Common Accessories 3.5 9 Slim I/O Solid State Relay G2RV-SR G3RV-SR Global standard size, low profile, slim (6.2 mm width) I/O solid state relay. G3RV-SR • 25% lower profile than conventional products, contributing to a smaller control panel. • Optimal slim, high frequency, high-speed opening and closing SSR (solid state relay). • Slim shape with a switching capacity up to 3 A (DC), and 2 A (AC). • Because MOSFET is used for the outlet element for the DC load, opening and closing load of 100 µA to 3 A is possible. • Check operating status at a glance with the operating display LED. • Mounted I/O SSR (solid-state relay) uses plug-in terminals with strong mechanical pins that do not bend. For the recent information on models that have been certified for safety standards, refer to your OMRON website. Refer to Safety Precautions on page 20. Common Precautions Features Common Accessories 10 Push-In Plus Terminal Block Terminal x 5 • Push-in • Screw Short bar insertion holes Release lever Release hole Operation display LED (Socket section) Operation display LED (SSR section) Terminal (insertion) hole Release lever Relay easily fixed/removed 90 mm 80 mm Plug-in terminal Terminal has strong mechanical pins that do not bend. G3RV-SR Model Number Structure Model Number Legend (1) (2) (3) (4) (5) (1) Basic model name G3RV: Slim I/O Solid State Relay (2) Sub type SR: Slim solid relay + integrated low profile socket (3) Terminal (wire connection) 500: Push-In Plus Terminal 700: Screw terminal (4) Output voltage specification A : AC output (triac) zero cross function available AL : AC output (triac) zero cross function not available D : DC output (MOS FET) G2RV-SR G3RV-SR @ @ @ - @ @ (5) Rated voltage input 12, 24 VDC 24, 48 VAC/VDC 100, 110, 200, 230 VAC G3RV-SR Common Precautions Common Accessories 11 G3RV-SR Ordering Information Terminal (wire connection) Applicable output load Zero cross function Rated input voltage (V) G2RV-SR DC AC/DC DC load — AC DC AC/DC Yes Push-In Plus Terminal G3RV-SR AC AC load DC AC/DC No AC Common Precautions DC AC/DC DC load — AC DC AC/DC Screw terminal Yes Common Accessories AC AC load DC AC/DC No AC Model 12 G3RV-SR500-D DC12 24 G3RV-SR500-D DC24 24 G3RV-SR500-D AC/DC24 48 G3RV-SR500-D AC/DC48 100 G3RV-SR500-D AC100 110 G3RV-SR500-D AC110 200 G3RV-SR500-D AC200 230 G3RV-SR500-D AC230 12 G3RV-SR500-A DC12 24 G3RV-SR500-A DC24 24 G3RV-SR500-A AC/DC24 48 G3RV-SR500-A AC/DC48 100 G3RV-SR500-A AC100 110 G3RV-SR500-A AC110 200 G3RV-SR500-A AC200 230 G3RV-SR500-A AC230 12 G3RV-SR500-AL DC12 24 G3RV-SR500-AL DC24 24 G3RV-SR500-AL AC/DC24 48 G3RV-SR500-AL AC/DC48 100 G3RV-SR500-AL AC100 110 G3RV-SR500-AL AC110 200 G3RV-SR500-AL AC200 230 G3RV-SR500-AL AC230 12 G3RV-SR700-D DC12 24 G3RV-SR700-D DC24 24 G3RV-SR700-D AC/DC24 48 G3RV-SR700-D AC/DC48 100 G3RV-SR700-D AC100 110 G3RV-SR700-D AC110 200 G3RV-SR700-D AC200 230 G3RV-SR700-D AC230 12 G3RV-SR700-A DC12 24 G3RV-SR700-A DC24 24 G3RV-SR700-A AC/DC24 48 G3RV-SR700-A AC/DC48 100 G3RV-SR700-A AC100 110 G3RV-SR700-A AC110 200 G3RV-SR700-A AC200 230 G3RV-SR700-A AC230 12 G3RV-SR700-AL DC12 24 G3RV-SR700-AL DC24 24 G3RV-SR700-AL AC/DC24 48 G3RV-SR700-AL AC/DC48 100 G3RV-SR700-AL AC100 110 G3RV-SR700-AL AC110 200 G3RV-SR700-AL AC200 230 G3RV-SR700-AL AC230 Note: Solid wire cannot be used for Push-In Plus terminal type. Make sure to use stranded wire or stranded wire with ferrules. 12 G3RV-SR Solid state relay for maintenance G2RV-SR Model Number Legend G3RV-@ @ S @ @ (1) (2) (3) (4) (1) Output voltage specification D: DC output 2: AC output (5) (3) Terminal S: Plug-in type (4) Zero cross functions Blank: Zero cross function available L: Zero cross function not available (2) Rated current 02: AC output 2 A 03: DC output 3 A (5) Rated input voltage Number: 12, 24, 48 VDC List of Models Rated output Load * Rated input voltage (socket) 12 VDC 24 VDC 24 VAC/VDC Model G3RV-202S DC12 G3RV-202S DC24 48 VAC/VDC Yes Phototriac AC Yes (green) G3RV-SR700/500-A AC230V G3RV-202SL DC12 G3RV-202SL DC24 24 VAC/VDC Photovoltage coupler DC – 3A (at 5 to 24 VDC) G3RV-SR700/500-AL AC110V G3RV-SR700/500-AL AC230V G3RV-D03SL DC12 G3RV-D03SL DC24 48 VAC/VDC G3RV-SR700/500-D DC12V G3RV-SR700/500-D DC24V G3RV-SR700/500-D AC/DC24V G3RV-SR700/500-D AC/DC48V 100 VAC 110 VAC G3RV-SR700/500-AL AC/DC24V G3RV-SR700/500-AL AC200V 230 VAC 24 VDC G3RV-SR700/500-AL DC24V G3RV-SR700/500-AL AC100V G3RV-202SL DC48 200 VAC 12 VDC G3RV-SR700/500-AL DC12V G3RV-SR700/500-AL AC/DC48V 100 VAC 110 VAC G3RV-SR700/500-A AC110V G3RV-SR700/500-A AC200V 48 VAC/VDC No G3RV-SR700/500-A AC/DC24V Common Precautions 24 VAC/VDC G3RV-SR700/500-A DC24V G3RV-SR700/500-A AC100V G3RV-202S DC48 200 VAC 2A (at 100 to 230 VAC 240 12 VDC VAC) 24 VDC G3RV-SR700/500-A DC12V G3RV-SR700/500-A AC/DC48V 100 VAC 110 VAC Applicable model G3RV-SR Insulation Operation Output Zero cross method Display (SSR) Function G3RV-SR700/500-D AC100V G3RV-D03SL DC48 G3RV-SR700/500-D AC110V G3RV-SR700/500-D AC200V 230 VAC G3RV-SR700/500-D AC230V * Different depending on the ambient temperature. For more details, refer to Load current vs. ambient rated temperature on page 16. Common Accessories 200 VAC 13 G3RV-SR Specifications Rating (ambient temperature 25°C) G2RV-SR Input G3RV-SR700/500-A series Rated current Rated input voltage AC 50 Hz DC 60 Hz Operation voltage Release voltage Input voltage Percentage of the rated voltage 10.8 V max. 12 VDC – – 15 mA 24 VDC – – 12 mA 21.6 V max. 24 VAC/VDC 20 mA 21 mA 11 mA 21.6 V max. 48 VAC/VDC 10 mA 11 mA 6 mA 43.2 V max. 100 VAC 7.5 mA 7.5 mA – 90 V max. 110 VAC 7.5 mA 7.7 mA – 99 V max. 200 VAC 7.3 mA 8.6 mA – 180 V max. 230 VAC 7.3 mA 8.6 mA – 207 V max. 1 V min. ±10% G3RV-SR G3RV-SR700/500-AL series Rated current Rated input voltage AC 50 Hz DC 60 Hz Operation voltage Common Precautions 12 VDC – – 15 mA 10.8 V max. 24 VDC – – 12 mA 21.6 V max. 24 VAC/VDC 20 mA 21 mA 11 mA 21.6 V max. 48 VAC/VDC 10 mA 11 mA 6 mA 43.2 V max. 100 VAC 7.5 mA 7.7 mA – 90 V max. 110 VAC 7.5 mA 7.7 mA – 99 V max. 200 VAC 7.3 mA 8.6 mA – 180 V max. 230 VAC 7.3 mA 8.6 mA – 207 V max. Release voltage 1 V min. Input voltage Percentage of the rated voltage ±10% G3RV-SR700/500-D series Rated current Rated input voltage AC 50 Hz DC 60 Hz Operation voltage 12 VDC – – 8 mA 10.8 V max. 24 VDC – – 4.5 mA 21.6 V max. Common Accessories 24 VAC/VDC 10.7 mA 11.1 mA 4.3 mA 21.6 V max. 48 VAC/VDC 9.6 mA 10.2 mA 6 mA 43.2 V max. 100 VAC 6.8 mA 7.2 mA – 90 V max. 110 VAC 6.8 mA 7.2 mA – 99 V max. 200 VAC 6.8 mA 8.1 mA – 180 V max. 230 VAC 6.8 mA 8.1 mA – 207 V max. Release voltage 1 V min. Input voltage Percentage of the rated voltage ±10% Output 14 Item G3RV-SR700/500-A(L) G3RV-SR700/500-D Rated load voltage 100 to 240 VAC (50/60 Hz) 5 to 24 VDC Load voltage range 75 to 264 VAC (50/60 Hz) 3 to 26.4 VDC Load current 0.1 to 2 A (Ambient temperature=25°C) 100 µA to 3 A (Ambient temperature=25°C) Inrush current resistance 30 A (60 Hz, 1 cycle) 30 A (60 Hz, 1 cycle) Permissible l2t; Joule integral value (reference value) 15A2s 9 A2 s Applied load capacity 400 W (Output voltage: 200 VAC) 72 W (Output voltage: 24 VDC) G3RV-SR Characteristics G3RV-SR700/500-A G3RV-SR700/500-AL G3RV-SR700/500-D Operate time 1/2 cycle of load power supply +1 ms max. 3 ms max. 6 ms max. Release time 60 ms max. 60 ms max. 60 ms max. Output ON voltage drop 1.6 V (RMS) max. Output ON resistance – 0.3 Ω max. (at 24 VDC) – 5 mA max. (at 200 VAC, 50/60 Hz) Insulation resistance 100 MΩ min. (at 500 VDC) 10 µA max. (at 24 VDC) Dielectric strength Between input and output 2,500 VAC 50/60 Hz 1 min Vibration resistance Malfunction: 10 to 55 to 10 Hz double amplitude 0.70 mm Shock resistance 300m/s2 Ambient operating temperature Storage: –30 to +100°C (with no icing or no condensation) Operating: –30 to +55°C (with no icing or no condensation) Ambient operating humidity 45 to 85% RH Weight Approx. 38 g Pollution degree 2 The degree of protection by IEC60529 IP20 Rated impulse dielectric strength 4.0 kV/III Load category LC-A Overload current profile 1.5Ie 1.1Ue 5s ON, 10s OFF, 10 cycles Rated insulation voltage 240 V G3RV-SR Leakage current DC-12 UL 508 (file No.E64562) Input ratings Contact ratings G3RV-SR700/500-D series 12, 24 VDC 24, 48 VAC/VDC 100, 110, 200, 230 VAC 24 VDC 3 A (resistive load) at 25°C G3RV-SR700/500-A(L) series 12, 24 VDC 24, 48 VAC/DC 100, 110, 200, 230 VAC 240 VAC 2 A (resistive load) at 25°C TÜV 62314 Model Input ratings Contact ratings 12, 24 VDC 24, 48 VAC/VDC 100, 110, 200, 230 VAC 24 VDC 3 A (resistive load) G3RV-SR700/500-A(L) series 12, 24 VDC 24, 48 VAC/VDC 100, 110, 200, 230 VAC 240 VAC 2 A (resistive load) Common Accessories G3RV-SR700/500-D series Common Precautions Approved standards Model G2RV-SR Item 15 G3RV-SR Engineering Data Load current vs. ambient rated temperature Product mounting spacing 10 mm (Separate Mounting) Close mounting (up to 5 units *) 5 Load current (A) Load current (A) G2RV-SR G3RV-SR700/500-A(L) series 4 5 4 3 3 2 2 1 1 0 −30 −20 0 20 25 40 55 60 80 0.2 0 −30 −20 100 0 20 25 Ambient temperature (°C) 40 55 60 80 100 Ambient temperature (°C) Close mounting (up to 5 units *) Load current (A) Load current (A) Product mounting spacing 10 mm (Separate Mounting) 5 4 5 4 3 3 2 2 1 0.5 0 −30 −20 0 20 25 40 55 60 80 0 −30 −20 100 0 20 25 Ambient temperature (°C) 40 55 60 80 100 Ambient temperature (°C) * When five or more are installed, install with 10 mm space between each. For details, please refer to Mounting on page 23. Inrush Current Resistance: Non-repetitive Keep the inrush current to below the inrush current resistance value (i.e., below the broken line) if it occurs repetitively. Common Accessories 16 G3RV-SR700/500-A(L) series G3RV-SR700/500-D series 40 Inrush current (A.Peak) Common Precautions 1 Inrush current (A.Peak) G3RV-SR G3RV-SR700/500-D series 35 30 25 40 35 30 25 20 20 15 15 10 10 5 5 0 10 30 50 100 300 500 1,000 3,000 5,000 Energized time (ms) 0 10 30 50 100 300 500 1,000 3,000 5,000 Energized time (ms) G3RV-SR Dimensions (unit: mm) Solid state relay + socket Terminal Arrangement/ Internal Connection Diagram (TOP VIEW) 12 VDC G2RV-SR Push-In Plus Terminal Block G3RV-SR500 Input circuit 78 max. A1 G3RV A2 A2– 3.4 (5.05) INPUT 74.5 65.89 A1+ 13 (+) 35.25 18.78 OUTPUT 14 (–) 12 14 13 78.77 90 max. 35.3 24 VDC Input circuit G3RV-SR The information in parentheses in for a DC output. A1 G3RV A2 A2– INPUT (5.05) A1+ 18.78 6.2 max. 35.25 OUTPUT 14 (–) 59.71 The information in parentheses in for a DC output. 12 14 13 Other voltage Input circuit A1 G3RV A2 A2– Common Precautions 51.72 13 (+) INPUT A1+ 13 (+) 14 (–) The information in parentheses in for a DC output. 12 14 13 * : Diode bridge : Light emitting diode Common Accessories OUTPUT 17 G3RV-SR Screw terminal G3RV-SR700 G2RV-SR Terminal Arrangement/ Internal Connection Diagram (TOP VIEW) 12 VDC 78 max. Input circuit A1 3.4 74.5 G3RV 65.89 35.18 (5.05) A2 A2– 18.71 INPUT A1+ 13 (+) OUTPUT 14 (–) G3RV-SR 78.77 35.3 90 max. The information in parentheses in for a DC output. 12 14 13 24 VDC Input circuit A1 (5.05) 18.71 G3RV 35.18 A2 6.2 max. 51.65 56.2 A2– INPUT A1+ 13 (+) Common Precautions OUTPUT 14 (–) The information in parentheses in for a DC output. 12 14 13 Other voltage Input circuit A1 G3RV A2 A2– INPUT A1+ 13 (+) Common Accessories 18 OUTPUT 14 (–) The information in parentheses in for a DC output. 12 14 13 * : Diode bridge : Light emitting diode G3RV-SR Solid state relay for maintenance Terminal Arrangement/ Internal Connection Diagram (TOP VIEW) G3RV-D03SL (input circuit) Input 30.5 max. Load G2RV-SR G3RV-D03SL G3RV-202S(L) 33 max. 15.8 14 1.8 3.5 13 A1 A2 G3RV-202S(L) (input circuit) 2.4 22 5.04 3 Input 5.2 max. Load 13 A1 A2 G3RV-SR 14 Common Precautions Common Accessories 19 G2RV-SR/G3RV-SR Safety Precautions Be sure to read the Safety Precautions for All Relays in the website at the following URL: www.omron247.com. G2RV-SR Format of Warning Indications WARNING Indicates a potentially hazardous situation which, if not avoided, will result in minor or moderate injury, or may result in serious injury or death. Additionally, there may be significant property damage. CAUTION Indicates a potentially hazardous situation which, if not avoided, may result in minor or moderate injury or in property damage. Precautions for Safe Use Indicates supplementary comments on what to do or avoid doing, to use the product safety. Precautions for Correct Use Includes operating precautions to ensure that the product will operate properly and that performance and functions will not be adversely affected. G3RV-SR Meaning of Graphic Symbols for Ensuring Product Safety Indicates the possibility of electric shock under specific conditions. Used for general CAUTION, WARNING, or DANGER precautions for which there is no specified symbol. (This symbol is also used as the alerting symbol, but shall not be used in this meaning on the product.) Indicates the possibility of explosion or rupture under specific conditions. Common Precautions Indicates the possibility of injuries by high temperature under specific conditions. Provide a space of at least 3 mm between the G2RVSR and ground. Not doing so may result in a ground fault. Precautions for Safe Use Transport • Do not use the product if it has been dropped on the ground. Dropping the product may adversely affect performance. • Do not drop the product or subject it to abnormal vibration or shock during transportation or mounting. Doing so may result in deterioration of performance, malfunction, or failure. • Do not transport the product without it being packaged. Doing so may result in damage, malfunction, or failure. • Do not transport the G3RV under the following conditions. Doing so may result in damage, malfunction, or deterioration of performance characteristics. • High temperature, high humidity conditions • Conditions such as temperature change that causes rapid condensation • Condition where it is not packaged Operating and Storage Environments • Do not use or store the product in the following locations. Doing so WARNING Ensure that the socket is not charged during wiring and maintenance. Not doing so may result in electric shock. may result in damage, malfunction, or deterioration of performance characteristics. • Do not store in locations subject to ambient storage temperatures outside the range –40 to 70°C (for G2RV) and outside the range –30 to 100°C (for G3RV). Do not touch the terminal section of the G2RV-SR or the surrounding area while the power is being supplied. Doing so may result in electric shock. CAUTION Common Accessories 20 Minor burns may occasionally occur. Do not touch the G3RV or the heat sink while the power is being supplied or immediately after the power supply has been turned OFF. The G3RV becomes extremely hot. Minor electrical shock may occasionally occur. Do not touch the G3RV terminal section (i.e., current carrying parts) while the power is being supplied. • Locations subject to relative humidity outside the range 5% to 85% (for G2RV) and outside the range 45% to 85% (for G3RV). • Locations subject to high temperature or high humidity. • Conditions such as temperature change that causes rapid condensation • Locations where corrosive gases or flammable gases are present • Location where rainwater or water droplets gets splashed • Location with splashes of water, oil, and chemicals, etc. • Locations with much dust, salt, and iron powder • Location with blockers The G3RV may rupture if short-circuit current flows. As protection against accidents due to short-circuiting, be sure to install protective devices, such as fuses and no-fuse breakers, on the power supply side. Minor electrical shock may occasionally occur. Do not touch the main circuit terminals on the G3RV immediately after the power supply has been turned OFF. Shock may result due to the electrical charge stored in the built-in snubber circuit. Note: G3RV-202S(L), G3RV-SR500/700-A(L) series models only • Where static electricity or noise occurs • Where strong electromagnetic field is generated • Where there is a risk of exposure to radioactivity • Do not use or store Sockets in environments that contain silicone gas, sulfidizing gas (e.g., SO2 or H2S), or organic gas, or near materials that contain silicone. Doing so may cause the contacts to be unstable or to fail. Handling • Keep the G3RV well ventilated. There is a risk of short-circuiting or burning due to G3RV overheating. G2RV-SR/G3RV-SR Mounting • Before you start wiring, please make sure that the socket is • Please insert the flat-blade screwdriver to the bottom of the hole. If • Do not use or store the product in the following locations. Doing so may result in damage, malfunction, or deterioration of performance characteristics. you do not insert the flat-blade screwdriver correctly, the cable will • Where vibration or shock is directly transmitted to the body not be connected correctly. • Do not use the product where the socket could touch a solvent • When lubricant such as oil is attached to the tip of the driver, the driver will fall off, with a risk of injury towards the workers. G2RV-SR securely attached to the mounting rail. If the socket is unstable, it may come loose with a risk of injury towards the workers. Precautions for Correct Use or alkaline agent. • Do not insert short bar in the hole for wire or screw driver, it may cause the result of failure of pull out. Usage • Please select the load within the rated range. Doing so may result If insert short bar in the hole for wire or screw driver and try to pull out, it may cause damage for short bar or socket. in damage, malfunction, or failure. • Please use the power of the rated frequency. It may cause malfunction, failure, or risk of burnout. Push-In Plus Terminal Block 1. Connecting Wires to the Push-In Plus Terminal Block Part Names of the Terminal Block • Install G3RV according to instructions Mounting on page 23. If you lead to short-circuiting or burning the output element. G3RV-SR install in the wrong direction, abnormal heat is generated, and may Release hole • G3RV is an SSR that generates heat. Please observe the ambient Terminal (Insertion) hole temperature setting range of G3RV. If installing in an enclosed space, set a fan, and ventilate. • When mounting G3RV to DIN rail, firmly fit it into the groove. If it is Connecting Wires with Ferrules Insert the ferrule straight into the terminal block until the end strikes the terminal block. not properly installed, there is a risk of it falling. Wiring • For the current to be applied, make sure a wire size with margin is used. Otherwise, excessive heat generated by the wires may cause burning. • Do not attempt to use the wire if the coat is torn. Not doing so may Release hole • Always turn OFF the power supply before performing wiring. Not Ferrules doing so may cause electrical shock. • The wires of the socket for G3RV socket should not be passed through the same duct as that being connected to the high-voltage power supply. Otherwise, inductive noise may damage the G3RV or cause it to malfunction. Push-In Plus Terminal Block • Do not wire anything to the release holes. • Do not tilt or twist a flat-blade screwdriver while it is inserted into a release hole on the terminal block. The terminal block may be damaged. Connecting Stranded Wires Use the following procedure to connect the wires to the terminal block. (1) Hold a flat-blade screwdriver at an angle and insert it into the release hole. The angle should be between 10°and15°. If the flat-blade screwdriver is inserted correctly, you will feel the spring in the release hole respond. (2) With the flat-blade screwdriver still inserted into the release hole, insert the wire into the terminal hole until it strikes the terminal block. (3) Remove the flat-blade screwdriver from the release hole. • Insert a flat-blade screwdriver into the release holes at an angle. The terminal block may be damaged if you insert the screwdriver (1) (3) Common Precautions Terminal (Insertion) hole result in electric shock. Flat-blade screwdriver straight in. 10 to 15° into a release hole. (2) Stranded Wires (2) • Do not bend the wire past its natural bending radius or pull on it with excessive force. Doing so may cause the wire disconnection. • Do not insert more than one wire into each terminal (insertion) hole. • To prevent wiring materials from smoking or ignition, use the wiring (3) (1) Checking Connections • After insertion, pull gently on the wire to make sure that it will not come out (i.e., to confirm that it is held by the terminal block). • To prevent short circuits, insert the stripped part of a stranded materials given in the following table. Stripping length Recommended Wire Ferrules When using terminal Ferrules When not using terminal 0.5 to 1.5 mm2/AWG20 to AWG16 10 mm 8 mm Note: Use Ferrules with UL certification (R/C). wire or the conductive part of a ferrule until it is hidden inside the terminal insertion hole. (See following diagram.) Common Accessories • Do not allow the flat-blade screwdriver to fall out while it is inserted Disposal • Do not dispose of the product by burning. 21 G2RV-SR/G3RV-SR G2RV-SR 2. Removing Wires from the Push-In Plus Terminal Block Screw Terminal Use the following procedure to remove wires from the terminal block. The same method is used to remove stranded wires and ferrules. • Screw terminal Applicable wire size Wired type (1) Hold a flat-blade screwdriver at an angle and insert it into the release hole. (2) With the flat-blade screwdriver still inserted into the release hole, remove the wire from the terminal insertion hole. (3) Remove the flat-blade screwdriver from the release hole. (3) (1) Flat-blade screwdriver 10 to 15° Stripping length Stranded wires, without ferrule 0.5 to 1.5 mm2 8 mm Stranded wires, with ferrule and plastic collar 0.5 to 1.5 mm2 8 mm Stranded wires with ferrule, without plastic collar 0.5 to 1.5 mm2 8 mm (3) (1) (2) (2) Wire • Tightening Torque 0.4 N · m • Electric wiring 3. Recommended ferrules and tools Recommended Ferrules Applicable wire Use the electric wire of specified size as shown above. The stripped wire length is 8 mm. Recommended ferrules G3RV-SR Ferrules Conduct length (mm2) (AWG) (mm) Phoenix Contact product Weidmuller product Wago product 0.5 20 8 AI0.5-8 H0.5/14 FE-0.5-8N-WH 0.75 18 8 AI0.75-8 H0.75/14 FE-0.75-8N-GY 1 18 8 AI1-8 H1.0/14 FE-1.0-8N-RD 1.5 16 8 AI1.5-8 H1.5/14 FE-1.5-8N-BK CRIMPFOX6 CRIMPFOX6T-F CRIMPFOX10S PZ6 roto Variocrimp4 Recommended crimp tool Screw terminal Common Precautions *1. Make sure that the outer diameter of the wire is smaller than the inner diameter of the insulating sleeve of the recommended ferrule. *2. Make sure that the ferrule processing dimensions conform to the following figure. 8 mm Stripping length Operating latching lever When operating the latching lever for G2RV-SR701/501 series, use a 2.5 mm width flat-blade screwdriver. • Applicable flat-blade screwdriver Flat-blade screwdriver with parallel cutting edge: shaft diameter 2.5 mm (3.0 mm max.) Parallel cutting edge flat-blade screwdriver 8 mm Shaft diameter 2.5 mm (3.0 mm max.) Wide flat-blade screwdriver 8 mm 2.1 mm max. Recommended Flat-blade Screwdriver Use a flat-blade screwdriver to connect and remove wires. Use the following flat-blade screwdriver. The following table is the manufacturer and format at the time in December 2015. • Return to its original state after using the latching lever. • Do not use the latching lever as a switch. • Operation durability of the latching lever is 100 times or more. Side Front • Do not keep the latching lever ON for a long period of time (24 2.5 mm dia. Common Accessories 22 Driver with a thick shaft cannot be used. • Always turn OFF the power supply before operating latching lever. 0.4 mm hours or more) in order to maintain the operation check function. 2.5 mm Model Manufacturer XW4Z-00B Omron ESD0.40×2.5 Wera SZF 0.4×2.5 Phoenix Contact 0.4×2.5×75 302 Wiha AEF.2.5×75 Facom 210-719 Wago SDI 0.4×2.5×75 Weidmuller G2RV-SR/G3RV-SR Incorrect Example Countermeasure 1 Vertical Direction Mounting surface Mounting surface Open protective cover Height of SSR Duct or other object blocking airflow Airflow Metal base SSR Duct or other object blocking airflow Use ducts that have a shallow depth, to provide a sufficient ventilation area. Duct or other object blocking airflow If the ducts cannot be made lower, place the SSR on a metal base so that it is not surrounded by the ducts. G3RV-SR Keep the protective cover open when using the latching lever. Move until the latching lever clicks to the ON position (ON state). After using the latching lever, in order to prevent malfunction, return the switch to contact normal position (OFF state), and make sure the protective cover is firmly closed. Duct or other object blocking airflow SSR SSR Do not enclose the SSR in a duct of the same height. It will interfere with the heat dissipation of SSR. Duct or other object blocking airflow G2RV-SR Contact operating position (on-state) Close protective cover Countermeasure 2 Recommended height of the duct is 1/2 or less of the height of the SSR Duct or other object blocking airflow Contact normal position Mounting surface Method of operation of the latching lever Be aware of airflow Duct or other object blocking airflow Using the latching lever Exhaust (Axial fan) Example: check the operation of the relay and the sequence circuit SSR SSR SSR • Since the G3RV uses electronic components, do not allow it to fall, vibrate, or apply shock that exceeds the criteria. Doing so may result in failure, malfunction, or deterioration of performance. • Tighten screw terminal for G3RV with a torque of 0.4 N · m. It may cause short-circuit failure or burning. terminal portion of G3RV. It may cause short-circuit failure or burning. • If the air inlet or air outlet has a filter, clean the filter regularly to Common Precautions • Please use the voltage and current suitable for the input and output Inlet prevent it from clogging to ensure an efficient flow of air. • Do not place objects that may obstruct the proper ventilation for outside or inside the inlet or exhaust port, and in the outside Mounting vicinity. Duct or other object blocking airflow • A heat exchanger, if used, should be located in front of the G3RV to ensure the efficiency of the heat exchanger. • Please observe the ambient temperature of G3RV. The rated current of the G3RV is measured at an ambient temperature of SSR 10 mm min. 60 mm min. 25°C. • The G3RV uses a semiconductor in the output element. This causes the temperature inside the control panel to increase due to heating resulting from the flow of electrical current through Vertical Direction the load. The G3RV reliability can be increased by adding a ventilation fan to the control panel to dispel this heat, thus lowering the ambient temperature of the G3RV. (It suggests that life expectancy is doubled by each 10°C reduction in ambient temperature.) EMI The G3RV is a Class A product (for industrial environments). When used in a residential environment, it may cause radio interference. In such case, the user may be required to take appropriate measures. * When five or more are installed, install with 10 mm space between each. Common Accessories 30 mm min. 80 mm min. 23 G2RV-SR/G3RV-SR For G2RV-SR/G3VR-SR G2RV-SR Common Accessories (order separately) Ordering Information Short Bars Appearance No. of poles Pitch 6.2 mm Colors Model * 2 PYDN-6.2-020@ 3 PYDN-6.2-030@ Red (R), Blue (S), Yellow (Y) 4 10 20 Maximum energizing current Minimum order (Quantity) PYDN-6.2-040@ 10 32 A PYDN-6.2-100@ PYDN-6.2-200@ Note: Use for wiring to the adjacent socket. * Replace the box (@) in the model number with the code for the covering color. @ color selection: R = red, S = blue, Y = yellow G3RV-SR Labels Appearance Minimum order Model 5 sheets (1 sheet/72 pieces) XW5Z-P2.5LB2 Separate Plate Appearance Model Common Precautions XW5Z-EP12 PLC interface unit Appearance I/O classification Common process PNP For input NPN PNP For output NPN Connection method Model Push-In P2RVC-8-I-5-1 Screw P2RVC-8-I-7-1 Push-In P2RVC-8-I-5 Push-In P2RVC-8-O-5-1 Screw P2RVC-8-O-7-1 Push-In P2RVC-8-O-5 Common Accessories Parts for DIN Track Mounting Appearance Type Model 1m PFP-100N DIN Tracks – 0.5 m PFP-50N End Plate* PFP-M Spacer PFP-S * When mounting components to DIN rail, prevent sliding using end plates (Model PFP-M). Refer to your OMRON website for details on PFP-@. 24 Minimum order (Quantity) 10 G2RV-SR/G3RV-SR ● Applicable Cables Appearance End A Cables with Loose Wires P2RV-A@C 8 I/O points Device end P2RV-A100C 2,000 P2RV-A200C 3,000 P2RV-A300C 5,000 P2RV-A500C 1,000 P2RV-4-100C 2,000 P2RV-4-200C 3,000 P2RV-4-300C 5,000 P2RV-4-500C 1,000 P2RV-4-100IMC 2,000 P2RV-4-200IMC 32 input points 300 P2RV-4-300IMC 5,000 P2RV-4-500IMC 1,000 P2RV-4-100IFC 2,000 P2RV-4-200IFC 300 L 8 output points 8 input points L 3,000 P2RV-4-300IFC 5,000 P2RV-4-500IFC 500 P2RV-A050C-OMR GRT1 1,000 P2RV-A100C-OMR GRT1 500 P2RV-A050IC-OMR GRT1 1,000 P2RV-A100IC-OMR GRT1 P2RV-A050C-OMR NX 1,000 P2RV-A100C-OMR NX 500 P2RV-A050IC-OMR NX 1,000 P2RV-A100IC-OMR NX PLC I/O Units with MIL connectors (1:4) CJ1W-ID232/ID262, etc. PLC I/O Units with Fujitsu connectors (1:4) CJ1W-ID231/ID261, etc. Slice I/O Units (1:1) For inputs: GRT1-ID8-1 For outputs: GRT1-OD8-1 PLC I/O Units with MIL connectors (1:1) For inputs: NX-ID4442 For outputs: NX-OD4256 Common Accessories 500 PLC I/O Units with MIL connectors (1:4) CJ1W-OD232/OD262, etc. Common Precautions 3,000 32 input points 8 output Cables with Connectors points (1:1) P2RV-A@C-OMR GRT1 8 input points Applicable Connectors G3RV-SR 300 L Cables with Connectors (1:1) P2RV-A@C-OMR NX 1,000 32 output points L Cables with Connectors (1:4) P2RV-4-@IFC End B PLC interface unit end L L Cables with Connectors (1:4) P2RV-4-@IMC Connecting Cables Various devices 70 Cables with Connectors (1:4) P2RV-4-@C Cable length L (mm) G2RV-SR Name 25 G2RV-SR/G3RV-SR Name Appearance G2RV-SR End A 32 input points End B Device end PLC interface unit end 32 output points Schneider Electric PLC Connecting Cables P2RV-@C-SCH-@ L 300 G3RV-SR 16 input points 16 output points L 300 32 input points Common Precautions Common Accessories 26 32 output points Siemens PLC Connecting Cables P2RV-@C-SIM-@ L 300 16 input points L 300 32 input points 32 output points L 300 Cable length L (mm) Connecting Cables 500 P2RV-050C-SCH-A 1,000 P2RV-100C-SCH-A 2,000 P2RV-200C-SCH-A 3,000 P2RV-300C-SCH-A 5,000 P2RV-500C-SCH-A 500 P2RV-050C-SCH-B 1,000 P2RV-100C-SCH-B 2,000 P2RV-200C-SCH-B 3,000 P2RV-300C-SCH-B 5,000 P2RV-500C-SCH-B 500 P2RV-050C-SCH-C 1,000 P2RV-100C-SCH-C 2,000 P2RV-200C-SCH-C 3,000 P2RV-300C-SCH-C 5,000 P2RV-500C-SCH-C 500 P2RV-050C-SCH-D 1,000 P2RV-100C-SCH-D 2,000 P2RV-200C-SCH-D 3,000 P2RV-300C-SCH-D 5,000 P2RV-500C-SCH-D 500 P2RV-050C-SIM-A 1,000 P2RV-100C-SIM-A 2,000 P2RV-200C-SIM-A 3,000 P2RV-300C-SIM-A 5,000 P2RV-500C-SIM-A 500 P2RV-050C-SIM-B 1,000 P2RV-100C-SIM-B 2,000 P2RV-200C-SIM-B 3,000 P2RV-300C-SIM-B 5,000 P2RV-500C-SIM-B 500 P2RV-050C-SIM-C 1,000 P2RV-100C-SIM-C 2,000 P2RV-200C-SIM-C 3,000 P2RV-300C-SIM-C 5,000 P2RV-500C-SIM-C 500 P2RV-050C-SIM-D 1,000 P2RV-100C-SIM-D 2,000 P2RV-200C-SIM-D 3,000 P2RV-300C-SIM-D 5,000 P2RV-500C-SIM-D 500 P2RV-050C-SIM-E 1,000 P2RV-100C-SIM-E 2,000 P2RV-200C-SIM-E 3,000 P2RV-300C-SIM-E 5,000 P2RV-500C-SIM-E Applicable Connectors Schneider Electric PLCs with 32-point connectors (1:4) For inputs: 140 DDI 353 00 For outputs: 140 DDO 353 00 Schneider Electric PLCs with 16-point connectors (1:2) For inputs: BMX DDI 1602 For outputs: BMX DDO 1602 Siemens PLCs with 32-point connectors (1:4) For inputs: 6ES7 321-1BL00-0AA0 For outputs: 6ES7 322-1BL00-0AA0 Siemens PLCs with 16-point connectors (1:2) For inputs: 6ES7 321-1BH02-0AA0 Siemens PLCs with 32-point connectors (1:4) For inputs: 6ES7 421-1BL-0AA0 For outputs: 6ES7 422-1BL-0AA0 G2RV-SR/G3RV-SR PLC interface unit G2RV-SR Ratings / characteristics Rated voltage 30 VAC/DC Rated current 0.5 A/poles, 2 A/unit Ambient operating temperature −40 to 55°C Electrical schematic Input P2RVC-8-I-@-1 (PNP) 1....................8 14 P2RVC-8-I-5 (NPN) 1....................8 14 11 11 G3RV-SR 1 3 5 7 9 2 4 6 8 10 1....................8 P2RVC-8-O-5 (NPN) 1....................8 A2 A2 A1 1 3 5 7 9 2 4 6 8 10 A1 1 3 5 7 9 2 4 6 8 10 Common Precautions Output P2RVC-8-O-@-1 (PNP) 1 3 5 7 9 2 4 6 8 10 Common Accessories 27 G2RV-SR/G3RV-SR Dimensions (unit: mm) PLC interface unit G2RV-SR Push-IN P2RVC-8-I-5(-1) P2RVC-8-O-5(-1) 49.60 67.16 G3RV-SR Common Precautions Common Accessories 28 12.68 7×6.20 29 Screw P2RVC-8-I-7-1 P2RVC-8-O-7-1 49.60 67.16 12.68 7×6.20 29 G2RV-SR/G3RV-SR (Except for PLC interface unit) Common Accessories (unit: mm) Short Bars PYDN-6.2-@@ (6.2 mm) 2 L Pitch No. of poles 1.20 6.2 mm 9 6.20 14 L (Length) Colors Model * 2 12.4 PYDN-6.2-020@ 3 18.6 PYDN-6.2-030@ 4 24.8 10 62 20 124 Red (R) Blue (S) Yellow (Y) Maximum carry current PYDN-6.2-040@ G2RV-SR Dimensions 32 A PYDN-6.2-100@ PYDN-6.2-200@ Note: Use the Short Bars for crossover wiring within one Socket or between Sockets. * Replace the box (@) in the model number with the code for the covering color. Separate Plate 12 56 G3RV-SR XW5Z-EP12 63 Refer to your OMRON website for details on the PFP-@. Common Precautions Parts for DIN Track Mounting Common Accessories 29 Terms and Conditions of Sale 1. Offer; Acceptance. These terms and conditions (these "Terms") are deemed part of all quotes, agreements, purchase orders, acknowledgments, price lists, catalogs, manuals, brochures and other documents, whether electronic or in writing, relating to the sale of products or services (collectively, the "Products") by Omron Electronics LLC and its subsidiary companies (“Omron”). Omron objects to any terms or conditions proposed in Buyer’s purchase order or other documents which are inconsistent with, or in addition to, these Terms. 2. Prices; Payment Terms. All prices stated are current, subject to change without notice by Omron. Omron reserves the right to increase or decrease prices on any unshipped portions of outstanding orders. Payments for Products are due net 30 days unless otherwise stated in the invoice. 3. Discounts. Cash discounts, if any, will apply only on the net amount of invoices sent to Buyer after deducting transportation charges, taxes and duties, and will be allowed only if (i) the invoice is paid according to Omron’s payment terms and (ii) Buyer has no past due amounts. 4. Interest. Omron, at its option, may charge Buyer 1-1/2% interest per month or the maximum legal rate, whichever is less, on any balance not paid within the stated terms. 5. Orders. Omron will accept no order less than $200 net billing. 6. Governmental Approvals. Buyer shall be responsible for, and shall bear all costs involved in, obtaining any government approvals required for the importation or sale of the Products. 7. Taxes. All taxes, duties and other governmental charges (other than general real property and income taxes), including any interest or penalties thereon, imposed directly or indirectly on Omron or required to be collected directly or indirectly by Omron for the manufacture, production, sale, delivery, importation, consumption or use of the Products sold hereunder (including customs duties and sales, excise, use, turnover and license taxes) shall be charged to and remitted by Buyer to Omron. 8. Financial. If the financial position of Buyer at any time becomes unsatisfactory to Omron, Omron reserves the right to stop shipments or require satisfactory security or payment in advance. If Buyer fails to make payment or otherwise comply with these Terms or any related agreement, Omron may (without liability and in addition to other remedies) cancel any unshipped portion of Products sold hereunder and stop any Products in transit until Buyer pays all amounts, including amounts payable hereunder, whether or not then due, which are owing to it by Buyer. Buyer shall in any event remain liable for all unpaid accounts. 9. Cancellation; Etc. Orders are not subject to rescheduling or cancellation unless Buyer indemnifies Omron against all related costs or expenses. 10. Force Majeure. Omron shall not be liable for any delay or failure in delivery resulting from causes beyond its control, including earthquakes, fires, floods, strikes or other labor disputes, shortage of labor or materials, accidents to machinery, acts of sabotage, riots, delay in or lack of transportation or the requirements of any government authority. 11. Shipping; Delivery. Unless otherwise expressly agreed in writing by Omron: a. Shipments shall be by a carrier selected by Omron; Omron will not drop ship except in “break down” situations. b. Such carrier shall act as the agent of Buyer and delivery to such carrier shall constitute delivery to Buyer; c. All sales and shipments of Products shall be FOB shipping point (unless otherwise stated in writing by Omron), at which point title and risk of loss shall pass from Omron to Buyer; provided that Omron shall retain a security interest in the Products until the full purchase price is paid; d. Delivery and shipping dates are estimates only; and e. Omron will package Products as it deems proper for protection against normal handling and extra charges apply to special conditions. 12. Claims. Any claim by Buyer against Omron for shortage or damage to the Products occurring before delivery to the carrier must be presented in writing to Omron within 30 days of receipt of shipment and include the original transportation bill signed by the carrier noting that the carrier received the Products from Omron in the condition claimed. 13. Warranties. (a) Exclusive Warranty. Omron’s exclusive warranty is that the Products will be free from defects in materials and workmanship for a period of twelve months from the date of sale by Omron (or such other period expressed in writing by Omron). Omron disclaims all other warranties, express or implied. (b) Limitations. OMRON MAKES NO WARRANTY OR REPRESENTATION, EXPRESS OR IMPLIED, ABOUT NON-INFRINGEMENT, MERCHANTABIL- 14. 15. 16. 17. 18. ITY OR FITNESS FOR A PARTICULAR PURPOSE OF THE PRODUCTS. BUYER ACKNOWLEDGES THAT IT ALONE HAS DETERMINED THAT THE PRODUCTS WILL SUITABLY MEET THE REQUIREMENTS OF THEIR INTENDED USE. Omron further disclaims all warranties and responsibility of any type for claims or expenses based on infringement by the Products or otherwise of any intellectual property right. (c) Buyer Remedy. Omron’s sole obligation hereunder shall be, at Omron’s election, to (i) replace (in the form originally shipped with Buyer responsible for labor charges for removal or replacement thereof) the non-complying Product, (ii) repair the non-complying Product, or (iii) repay or credit Buyer an amount equal to the purchase price of the non-complying Product; provided that in no event shall Omron be responsible for warranty, repair, indemnity or any other claims or expenses regarding the Products unless Omron’s analysis confirms that the Products were properly handled, stored, installed and maintained and not subject to contamination, abuse, misuse or inappropriate modification. Return of any Products by Buyer must be approved in writing by Omron before shipment. Omron Companies shall not be liable for the suitability or unsuitability or the results from the use of Products in combination with any electrical or electronic components, circuits, system assemblies or any other materials or substances or environments. Any advice, recommendations or information given orally or in writing, are not to be construed as an amendment or addition to the above warranty. See http://www.omron247.com or contact your Omron representative for published information. Limitation on Liability; Etc. OMRON COMPANIES SHALL NOT BE LIABLE FOR SPECIAL, INDIRECT, INCIDENTAL, OR CONSEQUENTIAL DAMAGES, LOSS OF PROFITS OR PRODUCTION OR COMMERCIAL LOSS IN ANY WAY CONNECTED WITH THE PRODUCTS, WHETHER SUCH CLAIM IS BASED IN CONTRACT, WARRANTY, NEGLIGENCE OR STRICT LIABILITY. Further, in no event shall liability of Omron Companies exceed the individual price of the Product on which liability is asserted. Indemnities. Buyer shall indemnify and hold harmless Omron Companies and their employees from and against all liabilities, losses, claims, costs and expenses (including attorney's fees and expenses) related to any claim, investigation, litigation or proceeding (whether or not Omron is a party) which arises or is alleged to arise from Buyer's acts or omissions under these Terms or in any way with respect to the Products. Without limiting the foregoing, Buyer (at its own expense) shall indemnify and hold harmless Omron and defend or settle any action brought against such Companies to the extent based on a claim that any Product made to Buyer specifications infringed intellectual property rights of another party. Property; Confidentiality. Any intellectual property in the Products is the exclusive property of Omron Companies and Buyer shall not attempt to duplicate it in any way without the written permission of Omron. Notwithstanding any charges to Buyer for engineering or tooling, all engineering and tooling shall remain the exclusive property of Omron. All information and materials supplied by Omron to Buyer relating to the Products are confidential and proprietary, and Buyer shall limit distribution thereof to its trusted employees and strictly prevent disclosure to any third party. Export Controls. Buyer shall comply with all applicable laws, regulations and licenses regarding (i) export of products or information; (iii) sale of products to “forbidden” or other proscribed persons; and (ii) disclosure to non-citizens of regulated technology or information. Miscellaneous. (a) Waiver. No failure or delay by Omron in exercising any right and no course of dealing between Buyer and Omron shall operate as a waiver of rights by Omron. (b) Assignment. Buyer may not assign its rights hereunder without Omron's written consent. (c) Law. These Terms are governed by the law of the jurisdiction of the home office of the Omron company from which Buyer is purchasing the Products (without regard to conflict of law principles). (d) Amendment. These Terms constitute the entire agreement between Buyer and Omron relating to the Products, and no provision may be changed or waived unless in writing signed by the parties. (e) Severability. If any provision hereof is rendered ineffective or invalid, such provision shall not invalidate any other provision. (f) Setoff. Buyer shall have no right to set off any amounts against the amount owing in respect of this invoice. (g) Definitions. As used herein, “including” means “including without limitation”; and “Omron Companies” (or similar words) mean Omron Corporation and any direct or indirect subsidiary or affiliate thereof. Certain Precautions on Specifications and Use 1. Suitability of Use. Omron Companies shall not be responsible for conformity with any standards, codes or regulations which apply to the combination of the Product in the Buyer’s application or use of the Product. At Buyer’s request, Omron will provide applicable third party certification documents identifying ratings and limitations of use which apply to the Product. This information by itself is not sufficient for a complete determination of the suitability of the Product in combination with the end product, machine, system, or other application or use. Buyer shall be solely responsible for determining appropriateness of the particular Product with respect to Buyer’s application, product or system. Buyer shall take application responsibility in all cases but the following is a non-exhaustive list of applications for which particular attention must be given: (i) Outdoor use, uses involving potential chemical contamination or electrical interference, or conditions or uses not described in this document. (ii) Use in consumer products or any use in significant quantities. (iii) Energy control systems, combustion systems, railroad systems, aviation systems, medical equipment, amusement machines, vehicles, safety equipment, and installations subject to separate industry or government regulations. (iv) Systems, machines and equipment that could present a risk to life or property. Please know and observe all prohibitions of use applicable to this Product. NEVER USE THE PRODUCT FOR AN APPLICATION INVOLVING SERIOUS RISK TO LIFE OR PROPERTY OR IN LARGE QUANTITIES WITHOUT ENSURING THAT THE SYSTEM AS A WHOLE HAS BEEN DESIGNED TO 2. 3. 4. 5. ADDRESS THE RISKS, AND THAT THE OMRON’S PRODUCT IS PROPERLY RATED AND INSTALLED FOR THE INTENDED USE WITHIN THE OVERALL EQUIPMENT OR SYSTEM. Programmable Products. Omron Companies shall not be responsible for the user’s programming of a programmable Product, or any consequence thereof. Performance Data. Data presented in Omron Company websites, catalogs and other materials is provided as a guide for the user in determining suitability and does not constitute a warranty. It may represent the result of Omron’s test conditions, and the user must correlate it to actual application requirements. Actual performance is subject to the Omron’s Warranty and Limitations of Liability. Change in Specifications. Product specifications and accessories may be changed at any time based on improvements and other reasons. It is our practice to change part numbers when published ratings or features are changed, or when significant construction changes are made. However, some specifications of the Product may be changed without any notice. When in doubt, special part numbers may be assigned to fix or establish key specifications for your application. Please consult with your Omron’s representative at any time to confirm actual specifications of purchased Product. Errors and Omissions. Information presented by Omron Companies has been checked and is believed to be accurate; however, no responsibility is assumed for clerical, typographical or proofreading errors or omissions. OMRON AUTOMATION AMERICAS HEADQUARTERS • Chicago, IL USA • 847.843.7900 • 800.556.6766 • www.omron247.com OMRON CANADA, INC. • HEAD OFFICE Toronto, ON, Canada • 416.286.6465 • 866.986.6766 • www.omron247.com OMRON ARGENTINA • SALES OFFICE Cono Sur • 54.11.4783.5300 OMRON ELECTRONICS DE MEXICO • HEAD OFFICE México DF • 52.55.59.01.43.00 • 01-800-226-6766 • mela@omron.com OMRON CHILE • SALES OFFICE Santiago • 56.9.9917.3920 OMRON ELECTRONICS DE MEXICO • SALES OFFICE Apodaca, N.L. • 52.81.11.56.99.20 • 01-800-226-6766 • mela@omron.com OTHER OMRON LATIN AMERICA SALES 54.11.4783.5300 OMRON ELETRÔNICA DO BRASIL LTDA • HEAD OFFICE São Paulo, SP, Brasil • 55.11.2101.6300 • www.omron.com.br OMRON EUROPE B.V. • Wegalaan 67-69, NL-2132 JD, Hoofddorp, The Netherlands. • +31 (0) 23 568 13 00 • www.industrial.omron.eu Controllers & I/O • Machine Automation Controllers (MAC) • Motion Controllers • Programmable Logic Controllers (PLC) • Temperature Controllers • Remote I/O Authorized Distributor: Robotics • Industrial Robots • Mobile Robots Operator Interfaces • Human Machine Interface (HMI) Motion & Drives • Machine Automation Controllers (MAC) • Motion Controllers • Servo Systems • Frequency Inverters Vision, Measurement & Identification • Vision Sensors & Systems • Measurement Sensors • Auto Identification Systems Sensing • Photoelectric Sensors • Fiber-Optic Sensors • Proximity Sensors • Rotary Encoders • Ultrasonic Sensors Safety • Safety Light Curtains • Safety Laser Scanners • Programmable Safety Systems • Safety Mats and Edges • Safety Door Switches • Emergency Stop Devices • Safety Switches & Operator Controls • Safety Monitoring/Force-guided Relays Control Components • Power Supplies • Timers • Counters • Programmable Relays • Digital Panel Meters • Monitoring Products Switches & Relays • Limit Switches • Pushbutton Switches • Electromechanical Relays • Solid State Relays Software • Programming & Configuration • Runtime J285I-E-01 06/16 Note: Specifications are subject to change. © 2016 Omron. All Rights Reserved. Printed on recycled paper. Printed in U.S.A. Mouser Electronics Authorized Distributor Click to View Pricing, Inventory, Delivery & Lifecycle Information: Omron: G2RV-1-S DC21 G2RV-1-S DC48 G2RV-1-S DC11 G3RV-202S DC12 G3RV-202S DC24 G3RV-202S DC48 G3RV-202SL DC12 G3RV-202SL DC24 G3RV-202SL DC48 G3RV-D03SL DC12 G3RV-D03SL DC24 G3RV-D03SL DC48 G3RV-SL500-A AC/DC48 G3RV-SL500-A AC110 G3RV-SL500-A AC230 G3RV-SL500-A DC12 G3RV-SL500A DC24 G3RV-SL500-AL AC230 G3RV-SL500-AL DC24 G3RV-SL500-D AC110 G3RV-SL500-D AC230 G3RVSL500-D DC12 G3RV-SL500-D DC24 G3RV-SL700-A AC/DC48 G3RV-SL700-A AC110 G3RV-SL700-A AC230 G3RV-SL700-A DC12 G3RV-SL700-A DC24 G3RV-SL700-AL AC110 G3RV-SL700-AL AC230 G3RV-SL700-AL DC24 G3RV-SL700-D AC/DC48 G3RV-SL700-D AC110 G3RV-SL700-D AC230 G3RV-SL700-D DC12 G3RVSL700-D DC24 G3RV-SL500-A AC/DC24 G3RV-SL500-AL AC110 G3RV-SL500-AL AC/DC24 G3RV-SL500-AL AC/DC48 G3RV-SL500-AL DC12 G3RV-SL500-D AC/DC24 G3RV-SL500-D AC/DC48 G3RV-SL700-A AC/DC24 G3RV-SL700-AL AC/DC24 G3RV-SL700-AL AC/DC48 G3RV-SL700-AL DC12 G3RV-SL700-D AC/DC24 G2RVSL700-AP AC230 G2RV-SL500-AP DC12 G2RV-SL500-AP AC230 G2RV-SL500-AP DC24 G2RV-SL500-AP AC110 G2RV-SL500-AP AC/DC24 G2RV-SL700-AP DC12 G2RV-SL700-AP AC110 G2RV-SL500-AP AC/DC48 G2RVSL700-AP AC/DC48 G2RV-SL700-AP AC/DC24 G2RV-SL700-AP DC24 G2RV-SL700-AC/DC48 G2RV-SL700-DC12 G2RV-SL700 AC230 G2RV-SL500 AC/DC48 G2RV-SL700-DC24 G2RV-SL500 AC110 G2RV-SL700-AC110 G2RV-SL500 DC12(DC11) G2RV-SL700-AC/DC24 G2RV-SL500 AC230 G2RV-SL500 AC/DC24 G2RV-1-S-AP DC11 G2RV-1-S-AP DC48 G2RV-1-S-AP DC21 G2RV-SL700 DC12(DC11) G2RV-SL700 DC24(DC21) G2RVSR500-AP ACDC24 PYDN-6.2-200S PYDN-6.2-020R PYDN-6.2-020S PYDN-6.2-020Y PYDN-6.2-030R PYDN-6.2030S PYDN-6.2-030Y G3RV-SR500-AL AC/DC24 G3RV-SR500-AL AC/DC48 G3RV-SR700-AL AC/DC24 G3RVSR700-AL AC/DC48 PYDN-6.2-200R PYDN-6.2-200Y G2RV-SR500-AP AC/DC48 G2RV-SR700-AP AC/DC24 G2RV-SR700-AP AC/DC48 PYDN-6.2-040R PYDN-6.2-040S PYDN-6.2-040Y PYDN-6.2-100R PYDN-6.2-100S PYDN-6.2-100Y G2RV-SL701-AC/DC24
PYDN-6.2-020R 价格&库存

很抱歉,暂时无法提供与“PYDN-6.2-020R”相匹配的价格&库存,您可以联系我们找货

免费人工找货