Slim I/O Relays
Global standard size, low profile
slim (6.2 mm width) I/O relays
G2RV-SR:
G3RV-SR:
• 25% lower profile than conventional products, contributing
to a smaller control panel.
• Push-In Plus terminal blocks reduce wiring work by 60%*
compared to conventional screw terminals.
• ‘Hand-free’ structure that holds an inserted flat-blade
screwdriver to achieve easier wiring work for stranded
wires.
G3RV-SR
• Electromechanical relays (G2RV-SR) and solid state
relays (G3RV-SR) are available.
• Screw terminal terminal block models are available.
• Plug-in terminal has strong mechanical pins that do not
bend.
* According to OMRON actual measurement data from November 2015.
G2RV-SR
G2RV-SR/G3RV-SR
For the recent information on models that have been certified
for safety standards, refer to your OMRON website.
Slim I/O Relay Types
G2RV-SR series mounted relay: electromagnetic relay ...... from page 2
G3RV-SR series mounted relay: solid state relay ................ from page 10
Common matter
Common Precautions
Refer to Safety Precautions on page 20.
Common precautions ................................................................ from page 20
Common accessories (order separately)................................. page 24
Common Accessories
1
Slim Electromechanical I/O Relay
G2RV-SR
G2RV-SR
Global standard size, low profile,
slim (6.2 mm width) I/O relay
G3RV-SR
• 25% lower profile than conventional products, contributing
to a smaller control panel.
• Opening and closing ability with one pole 6 A slim shape.
• Micro load products for one pole 50 mA using gold-plated
contacts for small load switching also available.
• Since G2RV has a transparent case, confirming the state
of the contact with the naked eye is possible.
• Screw terminal terminal block models are available.
• Plug-in type terminal has strong mechanical pins that do
not bend.
For the recent information on models that have been certified
for safety standards, refer to your OMRON website.
Refer to Safety Precautions on page 20.
Common Precautions
Common Accessories
2
Features
With latching lever
(Test switch)
Standard model/Micro load
Terminal x 5
• Push-in
• Screw
Release lever
Mechanical
indicator
• Operation
verification
which is linked
to the contact
Operation
display LED
(Socket section)
Push-In Plus Terminal Block
Protective cover
(Released state)
Protective cover
(Locked condition)
Latching lever
(Test switch)
Latching lever
(Test switch)
• Circuit check operation
Confirmation, reducing the inspection effort
PAT
"Foreign matter intrusion prevention structure"
"Malfunction prevention stopper"
Transparent case
Relay contact
Easy confirmation
of the situation
Release lever
Relay easily
fixed/removed
90 mm
80 mm
Plug-in terminal
Terminal has strong
mechanical pins that
do not bend.
Short bar insertion holes
Release hole
Terminal (insertion) hole
G2RV-SR
Model Number Structure
Model Number Legend
(1)
(2)
(3) (4)
(5)
(6)
(1) Basic model name
G2RV: Slim I/O Relay
(2) Sub type
SR: Slim relay + integrated low profile socket
(3) Terminal (wire connection)
50: Push-In Plus Terminal
70: Screw terminal
(5) Contact structure
Blank: Standard
AP: Microloads
(4) Latching lever (test switch)
0: Without latching lever
1: With latching lever
(6) Rated input voltage
12, 24 VDC
24, 48 VAC/VC
100, 110, 200, 230 VAC
G2RV-SR
G2RV-SR @@ @ - @ @
Ordering Information
Terminal
(Wire connection)
Latching lever
(Test switch)
Classification
Rated input voltage (V)
AC/DC
G2RV-SR500 AC200
230
G2RV-SR500 AC230
DC
24
G2RV-SR501 DC24
AC/DC
24
G2RV-SR501 AC/DC24
12
G2RV-SR500-AP DC12
24
G2RV-SR500-AP DC24
24
G2RV-SR500-AP AC/DC24
48
G2RV-SR500-AP AC/DC48
100
G2RV-SR500-AP AC100
110
G2RV-SR500-AP AC110
200
G2RV-SR500-AP AC200
230
G2RV-SR500-AP AC230
12
G2RV-SR700 DC12
24
G2RV-SR700 DC24
24
G2RV-SR700 AC/DC24
48
G2RV-SR700 AC/DC48
100
G2RV-SR700 AC100
110
G2RV-SR700 AC110
200
G2RV-SR700 AC200
230
G2RV-SR700 AC230
DC
24
G2RV-SR701 DC24
AC/DC
24
G2RV-SR701 AC/DC24
12
G2RV-SR700-AP DC12
No
AC
DC
AC/DC
No
Standard
AC
DC
AC/DC
Microloads
No
AC
24
G2RV-SR700-AP DC24
24
G2RV-SR700-AP AC/DC24
48
G2RV-SR700-AP AC/DC48
100
G2RV-SR700-AP AC100
110
G2RV-SR700-AP AC110
200
G2RV-SR700-AP AC200
230
G2RV-SR700-AP AC230
Note: Solid wire cannot be used for Push-In Plus terminal type. Make sure to use stranded wire or stranded wire with ferrules.
Common Accessories
G2RV-SR500 AC110
200
Common Precautions
110
AC/DC
Yes
G2RV-SR500 AC/DC24
G2RV-SR500 AC/DC48
DC
Screw terminal
24
G2RV-SR500 AC100
AC
Microloads
G2RV-SR500 DC24
100
Standard
Yes
G2RV-SR500 DC12
24
48
No
Push-In Plus
Terminal
12
G3RV-SR
DC
Model
3
G2RV-SR
Relay for Maintenance
G2RV-SR
Model Number Legend
G2RV-1 - S @ - @ - G @
(1) (2) (3)
(4)
(5)
(1) No. of poles
1: 1 pole
G2RV-1-SI-G
G2RV-1-S-G(-AP)
(6)
(4) Contact material
Blank: Silver alloy
AP: Silver alloy + gold plate
(2) Terminal
S: plug-in
(3) Latching lever (Test switch)
Blank: Without latching lever
I: With latching lever
(5) Types of relay for exchange
G: G2RV-SR series equipped
Relay
(6) Rated coil voltage
Number: 11, 21, 48 VDC
List of Models
G3RV-SR
Type
Latching
Lever
(Test switch)
No
Rated coil
voltage (V)
Model
11
G2RV-1-S-G DC11
21
G2RV-1-S-G DC21
G2RV-SR700/500 DC12V
G2RV-SR700/500 DC24V
G2RV-SR700/500 AC/DC24V
G2RV-SR700/500 AC/DC48V
DC
Standard
Applicable model
G2RV-SR700/500 AC100V
48
G2RV-1-S-G DC48
G2RV-SR700/500 AC110V
G2RV-SR700/500 AC200V
G2RV-SR700/500 AC230V
Common Precautions
Common Accessories
4
Yes
Microload No
DC
21
G2RV-1-SI-G DC21
11
G2RV-1-S-AP-G DC11
21
G2RV-1-S-AP-G DC21
G2RV-SR701/501 DC24V
G2RV-SR701/501 AC/DC24V
G2RV-SR700/500-AP DC12V
G2RV-SR700/500-AP DC24V
G2RV-SR700/500-AP AC/DC24V
G2RV-SR700/500-AP AC/DC48V
DC
G2RV-SR700/500-AP AC100V
48
G2RV-1-S-AP-G DC48
G2RV-SR700/500-AP AC110V
G2RV-SR700/500-AP AC200V
G2RV-SR700/500-AP AC230V
G2RV-SR
Specifications
Ratings
Operation
voltage
Rated current
Rated input
voltage
AC
50 Hz
DC
60 Hz
12 VDC
–
–
–
Release
voltage
Percentage of the rated voltage
27.2 mA
Power consumption
Maximum
allowable voltage
AC (VA)
Percentage of the
rated voltage
DC (mW)
–
Approx. 300 mW
Approx. 300 mW
24 VDC
–
13.3 mA
–
24 VAC/VDC
21.1 mA 22.5 mA
13.0 mA
Approx. 0.5 VA Approx. 300 mW
48 VAC/VDC
8.5 mA
9.0 mA
5.2 mA
100 VAC
7.1 mA
7.5 mA
–
110 VAC
7.1 mA
7.5 mA
–
Approx. 0.8 VA –
200 VAC
7.2 mA
7.9 mA
–
Approx. 1.7 VA –
230 VAC
7.3 mA
7.9 mA
–
Approx. 1.7 VA –
80% max.*
Approx. 0.4 VA Approx. 250 mW
10% min.
Approx. 0.8 VA –
110%
Contact ratings
Item
Standard (G2RV-SR700, 500, 701, 501)
For microloads (G2RV-SR700-AP, 500-AP) *2
SPDT
Load
Resistive load
(cosφ=1)
Inductive load
(cosφ=0.4, L/R=7ms)
Resistive load
(cosφ=1)
Rated load
6 A at 250 VAC
6 A at 30 VDC
2.5 A at 250 VAC
2 A at 30 VDC
50 mA at 30 VAC
50 mA at 36 VDC
Rated carry current
6A
50 mA
Maximum switching voltage
440 VAC, 125 VDC
30 VAC, 36 VDC
Maximum switching current
6A
Maximum switching power
1,500 VA
180 W
Failure rate P value
(reference value) *1
10 mA at 5 VDC
50 mA
–
1 mA at 100 mVDC
*1. P level: λ60=0.1×10 /times
This value is the value in switching frequency 120 operations/min.
*2. If the gold plating layer is destroyed, the number will be the same as the standard type.
Characteristics
Standard (G2RV-SR700, 500, 701, 501)
For microloads (G2RV-SR700-AP, 500-AP)
100 mΩ max.
Operate (Set) time *
20 ms max.
Release time *
AC, AC/DC: 40 ms max.
DC: 20 ms max.
Maximum operating frequency
Mechanical: 18,000 operations/h
Electrical: 1,800 operations/h (rated load)
Insulation resistance
1,000 MΩ min. (at 500 VDC)
Dielectric strength
Between coil and contacts: 4,000VAC 50/60 Hz 1 min
Contact between the same polarity: 1,000 VAC 50/60 Hz 1 min
Vibration resistance
Destruction: 10 to 55 to 10 Hz, single amplitude 0.50 mm (double amplitude 1.0 mm)
Malfunction: 10 to 55 to 10 Hz, single amplitude 0.50 mm (double amplitude 1.0 mm)
Shock resistance
Destruction: 1,000 m/s2
Malfunction: Energized 200m/s2, Non-energized 100m/s2
Endurance *
Mechanical
5,000,000 operations min.
Electrical
NO contact: 70,000 operations min.
NC contact: 50,000 operations min.
5,000,000 operations min.
Ambient operating temperature
Operating: –40 to +55°C (with no icing or condensation)
Ambient operating humidity
Operating: 5 to 85% RH
Weight
Approx. 30 g
Contact material
Ag alloy
Common Accessories
Contact resistance *
Common Precautions
500 VA
60 W
-6
Item
G3RV-SR
Note: The operating characteristics are measured at ambient temperature of 23°C.
* Operating voltage will be 85% max. for upside down mounting.
Contact configuration
G2RV-SR
Coil ratings
Ag alloy + Au plating
Note: Above values are initial values.
* Value is at ambient temperature of 23°C.
5
G2RV-SR
Approved standards
G2RV-SR
UL508 (file No.E41643)
Model
No. of poles
G2RV-SR series
Operation coil ratings
12 to 48 VDC
24 to 230 VAC
SPDT
Contact ratings
Operations
6 A at 250 VAC (Resistive load)
6 A at 30 VDC (Resistive load)
6,000
2 A at 400 VAC (Resistive
load)*
* If the load voltage exceeds 250 VAC, please attach with a spacing of 12 mm min., or use a separate plate (XW5Z-EP12).
12 mm 12 mm 12 mm
G3RV-SR
VDE (EN 61810-1)
Model
No. of poles
G2RV-SR series
Operation coil ratings
12, 24 VDC
24, 48 VAC/VDC
100, 110, 200, 230 VAC
SPDT
Contact ratings
Operations
6 A at 250 VAC (Resistive load)
50,000
6 A at 30 VDC (Resistive load)
50,000
2 A at 400 VAC (Resistive
6,000
load)*
* If the load voltage exceeds 250 VAC, please attach with a spacing of 12 mm min., or use a separate plate (XW5Z-EP12).
12 mm 12 mm 12 mm
Switching capacity of DC resistive load
1000
30 VDC resistive load
250 VAC resistive load
DC breaking current (A)
Endurance curve (N.O. side)
Common Accessories
Number of operations (x 103 operations)
Common Precautions
6
Engineering Data
10.0
1.0
100
30 VDC
resistive load
250 VAC resistive load
10
0
0.1
2
4
6
Opening and closing current (A)
20
60
100
140
180
220
DC switching voltage (V)
G2RV-SR
Dimensions
(unit: mm)
Slim I/O Relay + socket
Push-In Plus Terminal Block
Terminal Arrangement/Internal Connection Diagram
(TOP VIEW)
12 VDC
Input circuit
A1
G2RV-SR
Models without latching lever (without test switch)
G2RV-SR500
78 max.
G2RV-SR500-AP
A2
G2RV
3.4
74.5
65.89
Other voltage
35.25
18.78
(5.05)
Input circuit
A1
G2RV
12
A2
14
11
78.77
G3RV-SR
90 max.
35.3
24 VDC
Input circuit
12
A1
14
A2
G2RV
11
*
: Diode bridge
(5.05)
: Light emitting diode
18.78
6.2 max.
35.25
51.72
59.71
12
14
Models with latching lever (with test switch)
G2RV-SR501
Terminal Arrangement/Internal Connection Diagram
(TOP VIEW)
12 VDC
81 max.
Input circuit
A1
A2
G2RV
3.4
(5.05)
77.5
65.89
Other voltage
35.25
18.78
Input circuit
A1
G2RV
12
A2
11
78.77
24 VDC
90 max.
Input circuit
A1
12
14
A2
G2RV
11
*
(5.05)
: Diode bridge
: Light emitting diode
18.78
6.2 max.
35.25
51.72
59.71
12
Common Accessories
14
35.3
Common Precautions
11
14
11
7
G2RV-SR
Screw terminal
G2RV-SR
Models without latching lever (without test switch)
G2RV-SR700
G2RV-SR700-AP
Terminal Arrangement/Internal Connection Diagram
(TOP VIEW)
12 VDC
Input circuit
78 max.
A1
G2RV
3.4
A2
74.5
Other voltage
65.89
35.18
Input circuit
18.71
(5.05)
A1
G2RV
12
A2
14
11
78.77
35.3
90 max.
G3RV-SR
24 VDC
Input circuit
12
A1
14
A2
G2RV
11
*
(5.05)
18.71
: Diode bridge
: Light emitting diode
35.18
6.2 max.
51.65
56.2
12
14
Common Precautions
11
Models with latching lever (with test switch)
G2RV-SR701
Terminal Arrangement/Internal Connection Diagram
(TOP VIEW)
12 VDC
Input circuit
81 max.
A1
G2RV
3.4
A2
77.5
Other voltage
65.89
35.18
(5.05)
Input circuit
18.71
A1
G2RV
12
A2
14
Common Accessories
11
78.77
35.3
24 VDC
90 max.
Input circuit
14
A2
G2RV
11
*
(5.05)
18.71
: Diode bridge
: Light emitting diode
35.18
6.2 max.
51.65
56.2
12
14
11
8
12
A1
G2RV-SR
Relay for maintenance
5.2 max.
G2RV-SR
Models without latching lever
G2RV-1-S-G
G2RV-1-S-AP-G
30.5 max.
Terminal Arrangement/
Internal Connection Diagram
(TOP VIEW)
33 max.
16.2
0.5
14 11 12
A1 A2
G3RV-SR
1.8
(Input circuit)
2.4
3.5
5.04
5.04
22
3
Models with latching lever (test switch)
G2RV-1-SI-G
30.5 max.
Terminal Arrangement/
Internal Connection Diagram
(TOP VIEW)
(Input circuit)
36 max.
14 11 12
16.2
1.8
A1 A2
Common Precautions
5.2 max.
0.5
2.4
5.04
5.04
22
3
Common Accessories
3.5
9
Slim I/O Solid State Relay
G2RV-SR
G3RV-SR
Global standard size, low profile, slim
(6.2 mm width) I/O solid state relay.
G3RV-SR
• 25% lower profile than conventional products, contributing to a
smaller control panel.
• Optimal slim, high frequency, high-speed opening and closing
SSR (solid state relay).
• Slim shape with a switching capacity up to 3 A (DC), and
2 A (AC).
• Because MOSFET is used for the outlet element for the DC
load, opening and closing load of 100 µA to 3 A is possible.
• Check operating status at a glance with the operating display
LED.
• Mounted I/O SSR (solid-state relay) uses plug-in terminals with
strong mechanical pins that do not bend.
For the recent information on models that have been certified
for safety standards, refer to your OMRON website.
Refer to Safety Precautions on page 20.
Common Precautions
Features
Common Accessories
10
Push-In Plus Terminal Block
Terminal x 5
• Push-in
• Screw
Short bar insertion holes
Release lever
Release hole
Operation display LED
(Socket section)
Operation
display LED
(SSR section)
Terminal (insertion) hole
Release lever
Relay easily
fixed/removed
90 mm
80 mm
Plug-in terminal
Terminal has strong
mechanical pins that
do not bend.
G3RV-SR
Model Number Structure
Model Number Legend
(1)
(2)
(3)
(4)
(5)
(1) Basic model name
G3RV: Slim I/O Solid State Relay
(2) Sub type
SR: Slim solid relay + integrated low profile socket
(3) Terminal (wire connection)
500: Push-In Plus Terminal
700: Screw terminal
(4) Output voltage specification
A : AC output (triac) zero cross function available
AL : AC output (triac) zero cross function not available
D : DC output (MOS FET)
G2RV-SR
G3RV-SR @ @ @ - @ @
(5) Rated voltage input
12, 24 VDC
24, 48 VAC/VDC
100, 110, 200, 230 VAC
G3RV-SR
Common Precautions
Common Accessories
11
G3RV-SR
Ordering Information
Terminal
(wire connection)
Applicable
output load
Zero cross
function
Rated input voltage
(V)
G2RV-SR
DC
AC/DC
DC load
—
AC
DC
AC/DC
Yes
Push-In Plus Terminal
G3RV-SR
AC
AC load
DC
AC/DC
No
AC
Common Precautions
DC
AC/DC
DC load
—
AC
DC
AC/DC
Screw terminal
Yes
Common Accessories
AC
AC load
DC
AC/DC
No
AC
Model
12
G3RV-SR500-D DC12
24
G3RV-SR500-D DC24
24
G3RV-SR500-D AC/DC24
48
G3RV-SR500-D AC/DC48
100
G3RV-SR500-D AC100
110
G3RV-SR500-D AC110
200
G3RV-SR500-D AC200
230
G3RV-SR500-D AC230
12
G3RV-SR500-A DC12
24
G3RV-SR500-A DC24
24
G3RV-SR500-A AC/DC24
48
G3RV-SR500-A AC/DC48
100
G3RV-SR500-A AC100
110
G3RV-SR500-A AC110
200
G3RV-SR500-A AC200
230
G3RV-SR500-A AC230
12
G3RV-SR500-AL DC12
24
G3RV-SR500-AL DC24
24
G3RV-SR500-AL AC/DC24
48
G3RV-SR500-AL AC/DC48
100
G3RV-SR500-AL AC100
110
G3RV-SR500-AL AC110
200
G3RV-SR500-AL AC200
230
G3RV-SR500-AL AC230
12
G3RV-SR700-D DC12
24
G3RV-SR700-D DC24
24
G3RV-SR700-D AC/DC24
48
G3RV-SR700-D AC/DC48
100
G3RV-SR700-D AC100
110
G3RV-SR700-D AC110
200
G3RV-SR700-D AC200
230
G3RV-SR700-D AC230
12
G3RV-SR700-A DC12
24
G3RV-SR700-A DC24
24
G3RV-SR700-A AC/DC24
48
G3RV-SR700-A AC/DC48
100
G3RV-SR700-A AC100
110
G3RV-SR700-A AC110
200
G3RV-SR700-A AC200
230
G3RV-SR700-A AC230
12
G3RV-SR700-AL DC12
24
G3RV-SR700-AL DC24
24
G3RV-SR700-AL AC/DC24
48
G3RV-SR700-AL AC/DC48
100
G3RV-SR700-AL AC100
110
G3RV-SR700-AL AC110
200
G3RV-SR700-AL AC200
230
G3RV-SR700-AL AC230
Note: Solid wire cannot be used for Push-In Plus terminal type. Make sure to use stranded wire or stranded wire with ferrules.
12
G3RV-SR
Solid state relay for maintenance
G2RV-SR
Model Number Legend
G3RV-@ @ S @ @
(1) (2) (3) (4)
(1) Output voltage
specification
D: DC output
2: AC output
(5)
(3) Terminal
S: Plug-in type
(4) Zero cross functions
Blank: Zero cross function available
L: Zero cross function not available
(2) Rated current
02: AC output 2 A
03: DC output 3 A
(5) Rated input voltage
Number: 12, 24, 48 VDC
List of Models
Rated
output
Load *
Rated input
voltage
(socket)
12 VDC
24 VDC
24 VAC/VDC
Model
G3RV-202S DC12
G3RV-202S DC24
48 VAC/VDC
Yes
Phototriac
AC
Yes
(green)
G3RV-SR700/500-A AC230V
G3RV-202SL DC12
G3RV-202SL DC24
24 VAC/VDC
Photovoltage
coupler
DC
–
3A
(at 5 to
24 VDC)
G3RV-SR700/500-AL AC110V
G3RV-SR700/500-AL AC230V
G3RV-D03SL DC12
G3RV-D03SL DC24
48 VAC/VDC
G3RV-SR700/500-D DC12V
G3RV-SR700/500-D DC24V
G3RV-SR700/500-D AC/DC24V
G3RV-SR700/500-D AC/DC48V
100 VAC
110 VAC
G3RV-SR700/500-AL AC/DC24V
G3RV-SR700/500-AL AC200V
230 VAC
24 VDC
G3RV-SR700/500-AL DC24V
G3RV-SR700/500-AL AC100V
G3RV-202SL DC48
200 VAC
12 VDC
G3RV-SR700/500-AL DC12V
G3RV-SR700/500-AL AC/DC48V
100 VAC
110 VAC
G3RV-SR700/500-A AC110V
G3RV-SR700/500-A AC200V
48 VAC/VDC
No
G3RV-SR700/500-A AC/DC24V
Common Precautions
24 VAC/VDC
G3RV-SR700/500-A DC24V
G3RV-SR700/500-A AC100V
G3RV-202S DC48
200 VAC
2A
(at 100 to 230 VAC
240
12 VDC
VAC)
24 VDC
G3RV-SR700/500-A DC12V
G3RV-SR700/500-A AC/DC48V
100 VAC
110 VAC
Applicable model
G3RV-SR
Insulation Operation Output Zero cross
method Display (SSR) Function
G3RV-SR700/500-D AC100V
G3RV-D03SL DC48
G3RV-SR700/500-D AC110V
G3RV-SR700/500-D AC200V
230 VAC
G3RV-SR700/500-D AC230V
* Different depending on the ambient temperature.
For more details, refer to Load current vs. ambient rated temperature on page 16.
Common Accessories
200 VAC
13
G3RV-SR
Specifications
Rating (ambient temperature 25°C)
G2RV-SR
Input
G3RV-SR700/500-A series
Rated current
Rated input
voltage
AC
50 Hz
DC
60 Hz
Operation
voltage
Release
voltage
Input voltage
Percentage of the
rated voltage
10.8 V max.
12 VDC
–
–
15 mA
24 VDC
–
–
12 mA
21.6 V max.
24 VAC/VDC
20 mA
21 mA
11 mA
21.6 V max.
48 VAC/VDC
10 mA
11 mA
6 mA
43.2 V max.
100 VAC
7.5 mA
7.5 mA
–
90 V max.
110 VAC
7.5 mA
7.7 mA
–
99 V max.
200 VAC
7.3 mA
8.6 mA
–
180 V max.
230 VAC
7.3 mA
8.6 mA
–
207 V max.
1 V min.
±10%
G3RV-SR
G3RV-SR700/500-AL series
Rated current
Rated input
voltage
AC
50 Hz
DC
60 Hz
Operation
voltage
Common Precautions
12 VDC
–
–
15 mA
10.8 V max.
24 VDC
–
–
12 mA
21.6 V max.
24 VAC/VDC
20 mA
21 mA
11 mA
21.6 V max.
48 VAC/VDC
10 mA
11 mA
6 mA
43.2 V max.
100 VAC
7.5 mA
7.7 mA
–
90 V max.
110 VAC
7.5 mA
7.7 mA
–
99 V max.
200 VAC
7.3 mA
8.6 mA
–
180 V max.
230 VAC
7.3 mA
8.6 mA
–
207 V max.
Release
voltage
1 V min.
Input voltage
Percentage of the
rated voltage
±10%
G3RV-SR700/500-D series
Rated current
Rated input
voltage
AC
50 Hz
DC
60 Hz
Operation
voltage
12 VDC
–
–
8 mA
10.8 V max.
24 VDC
–
–
4.5 mA
21.6 V max.
Common Accessories
24 VAC/VDC
10.7 mA
11.1 mA
4.3 mA
21.6 V max.
48 VAC/VDC
9.6 mA
10.2 mA
6 mA
43.2 V max.
100 VAC
6.8 mA
7.2 mA
–
90 V max.
110 VAC
6.8 mA
7.2 mA
–
99 V max.
200 VAC
6.8 mA
8.1 mA
–
180 V max.
230 VAC
6.8 mA
8.1 mA
–
207 V max.
Release
voltage
1 V min.
Input voltage
Percentage of the
rated voltage
±10%
Output
14
Item
G3RV-SR700/500-A(L)
G3RV-SR700/500-D
Rated load voltage
100 to 240 VAC (50/60 Hz)
5 to 24 VDC
Load voltage range
75 to 264 VAC (50/60 Hz)
3 to 26.4 VDC
Load current
0.1 to 2 A (Ambient temperature=25°C) 100 µA to 3 A (Ambient temperature=25°C)
Inrush current resistance
30 A (60 Hz, 1 cycle)
30 A (60 Hz, 1 cycle)
Permissible l2t; Joule integral value
(reference value)
15A2s
9 A2 s
Applied load capacity
400 W
(Output voltage: 200 VAC)
72 W
(Output voltage: 24 VDC)
G3RV-SR
Characteristics
G3RV-SR700/500-A
G3RV-SR700/500-AL
G3RV-SR700/500-D
Operate time
1/2 cycle of load power supply
+1 ms max.
3 ms max.
6 ms max.
Release time
60 ms max.
60 ms max.
60 ms max.
Output ON voltage drop
1.6 V (RMS) max.
Output ON resistance
–
0.3 Ω max. (at 24 VDC)
–
5 mA max. (at 200 VAC, 50/60 Hz)
Insulation resistance
100 MΩ min. (at 500 VDC)
10 µA max. (at 24 VDC)
Dielectric strength
Between input and output 2,500 VAC 50/60 Hz 1 min
Vibration resistance
Malfunction: 10 to 55 to 10 Hz double amplitude 0.70 mm
Shock resistance
300m/s2
Ambient operating temperature
Storage: –30 to +100°C (with no icing or no condensation)
Operating: –30 to +55°C (with no icing or no condensation)
Ambient operating humidity
45 to 85% RH
Weight
Approx. 38 g
Pollution degree
2
The degree of protection by
IEC60529
IP20
Rated impulse dielectric
strength
4.0 kV/III
Load category
LC-A
Overload current profile
1.5Ie 1.1Ue
5s ON, 10s OFF, 10 cycles
Rated insulation voltage
240 V
G3RV-SR
Leakage current
DC-12
UL 508 (file No.E64562)
Input ratings
Contact ratings
G3RV-SR700/500-D series
12, 24 VDC
24, 48 VAC/VDC
100, 110, 200, 230 VAC
24 VDC 3 A (resistive load) at 25°C
G3RV-SR700/500-A(L) series
12, 24 VDC
24, 48 VAC/DC
100, 110, 200, 230 VAC
240 VAC 2 A (resistive load) at 25°C
TÜV 62314
Model
Input ratings
Contact ratings
12, 24 VDC
24, 48 VAC/VDC
100, 110, 200, 230 VAC
24 VDC 3 A (resistive load)
G3RV-SR700/500-A(L) series
12, 24 VDC
24, 48 VAC/VDC
100, 110, 200, 230 VAC
240 VAC 2 A (resistive load)
Common Accessories
G3RV-SR700/500-D series
Common Precautions
Approved standards
Model
G2RV-SR
Item
15
G3RV-SR
Engineering Data
Load current vs. ambient rated temperature
Product mounting spacing 10 mm (Separate Mounting)
Close mounting (up to 5 units *)
5
Load current (A)
Load current (A)
G2RV-SR
G3RV-SR700/500-A(L) series
4
5
4
3
3
2
2
1
1
0
−30 −20
0
20 25
40
55 60
80
0.2
0
−30 −20
100
0
20 25
Ambient temperature (°C)
40
55 60
80
100
Ambient temperature (°C)
Close mounting (up to 5 units *)
Load current (A)
Load current (A)
Product mounting spacing 10 mm (Separate Mounting)
5
4
5
4
3
3
2
2
1
0.5
0
−30 −20
0
20 25
40
55 60
80
0
−30 −20
100
0
20 25
Ambient temperature (°C)
40
55 60
80
100
Ambient temperature (°C)
* When five or more are installed, install with 10 mm space between
each.
For details, please refer to Mounting on page 23.
Inrush Current Resistance: Non-repetitive
Keep the inrush current to below the inrush current resistance value (i.e., below the broken line) if it occurs repetitively.
Common Accessories
16
G3RV-SR700/500-A(L) series
G3RV-SR700/500-D series
40
Inrush current (A.Peak)
Common Precautions
1
Inrush current (A.Peak)
G3RV-SR
G3RV-SR700/500-D series
35
30
25
40
35
30
25
20
20
15
15
10
10
5
5
0
10
30 50
100
300 500 1,000
3,000 5,000
Energized time (ms)
0
10
30 50
100
300 500 1,000
3,000 5,000
Energized time (ms)
G3RV-SR
Dimensions
(unit: mm)
Solid state relay + socket
Terminal Arrangement/
Internal Connection Diagram
(TOP VIEW)
12 VDC
G2RV-SR
Push-In Plus Terminal Block
G3RV-SR500
Input circuit
78 max.
A1
G3RV
A2
A2–
3.4
(5.05)
INPUT
74.5
65.89
A1+
13 (+)
35.25
18.78
OUTPUT
14 (–)
12
14
13
78.77
90 max.
35.3
24 VDC
Input circuit
G3RV-SR
The information in
parentheses in for
a DC output.
A1
G3RV
A2
A2–
INPUT
(5.05)
A1+
18.78
6.2 max.
35.25
OUTPUT
14 (–)
59.71
The information in
parentheses in for
a DC output.
12
14
13
Other voltage
Input circuit
A1
G3RV
A2
A2–
Common Precautions
51.72
13 (+)
INPUT
A1+
13 (+)
14 (–)
The information in
parentheses in for
a DC output.
12
14
13
*
: Diode bridge
: Light emitting diode
Common Accessories
OUTPUT
17
G3RV-SR
Screw terminal
G3RV-SR700
G2RV-SR
Terminal Arrangement/
Internal Connection Diagram
(TOP VIEW)
12 VDC
78 max.
Input circuit
A1
3.4
74.5
G3RV
65.89
35.18
(5.05)
A2
A2–
18.71
INPUT
A1+
13 (+)
OUTPUT
14 (–)
G3RV-SR
78.77
35.3
90 max.
The information in
parentheses in for
a DC output.
12
14
13
24 VDC
Input circuit
A1
(5.05)
18.71
G3RV
35.18
A2
6.2 max.
51.65
56.2
A2–
INPUT
A1+
13 (+)
Common Precautions
OUTPUT
14 (–)
The information in
parentheses in for
a DC output.
12
14
13
Other voltage
Input circuit
A1
G3RV
A2
A2–
INPUT
A1+
13 (+)
Common Accessories
18
OUTPUT
14 (–)
The information in
parentheses in for
a DC output.
12
14
13
*
: Diode bridge
: Light emitting diode
G3RV-SR
Solid state relay for maintenance
Terminal Arrangement/
Internal Connection Diagram
(TOP VIEW)
G3RV-D03SL (input circuit)
Input
30.5 max.
Load
G2RV-SR
G3RV-D03SL
G3RV-202S(L)
33 max.
15.8
14
1.8
3.5
13
A1 A2
G3RV-202S(L) (input circuit)
2.4
22
5.04
3
Input
5.2 max.
Load
13
A1 A2
G3RV-SR
14
Common Precautions
Common Accessories
19
G2RV-SR/G3RV-SR
Safety Precautions
Be sure to read the Safety Precautions for All Relays in the website at the following URL:
www.omron247.com.
G2RV-SR
Format of Warning Indications
WARNING
Indicates a potentially hazardous situation
which, if not avoided, will result in minor or
moderate injury, or may result in serious
injury or death. Additionally, there may be
significant property damage.
CAUTION
Indicates a potentially hazardous situation
which, if not avoided, may result in minor or
moderate injury or in property damage.
Precautions
for Safe Use
Indicates supplementary comments on
what to do or avoid doing, to use the
product safety.
Precautions
for Correct
Use
Includes operating precautions to ensure
that the product will operate properly and
that performance and functions will not be
adversely affected.
G3RV-SR
Meaning of Graphic Symbols for Ensuring Product Safety
Indicates the possibility of electric shock under
specific conditions.
Used for general CAUTION, WARNING, or
DANGER precautions for which there is no
specified symbol. (This symbol is also used as
the alerting symbol, but shall not be used in this
meaning on the product.)
Indicates the possibility of explosion or rupture
under specific conditions.
Common Precautions
Indicates the possibility of injuries by high
temperature under specific conditions.
Provide a space of at least 3 mm between the G2RVSR and ground. Not doing so may result in a ground
fault.
Precautions for Safe Use
Transport
• Do not use the product if it has been dropped on the ground.
Dropping the product may adversely affect performance.
• Do not drop the product or subject it to abnormal vibration or shock
during transportation or mounting. Doing so may result in
deterioration of performance, malfunction, or failure.
• Do not transport the product without it being packaged. Doing so
may result in damage, malfunction, or failure.
• Do not transport the G3RV under the following conditions. Doing
so may result in damage, malfunction, or deterioration of
performance characteristics.
• High temperature, high humidity conditions
• Conditions such as temperature change that causes rapid
condensation
• Condition where it is not packaged
Operating and Storage Environments
• Do not use or store the product in the following locations. Doing so
WARNING
Ensure that the socket is not charged during wiring and
maintenance. Not doing so may result in electric shock.
may result in damage, malfunction, or deterioration of performance
characteristics.
• Do not store in locations subject to ambient storage
temperatures outside the range –40 to 70°C (for G2RV) and
outside the range –30 to 100°C (for G3RV).
Do not touch the terminal section of the G2RV-SR or
the surrounding area while the power is being
supplied. Doing so may result in electric shock.
CAUTION
Common Accessories
20
Minor burns may occasionally occur.
Do not touch the G3RV or the heat sink while the
power is being supplied or immediately after the
power supply has been turned OFF.
The G3RV becomes extremely hot.
Minor electrical shock may occasionally occur.
Do not touch the G3RV terminal section (i.e., current
carrying parts) while the power is being supplied.
• Locations subject to relative humidity outside the range 5% to
85% (for G2RV) and outside the range 45% to 85% (for G3RV).
• Locations subject to high temperature or high humidity.
• Conditions such as temperature change that causes rapid
condensation
• Locations where corrosive gases or flammable gases are present
• Location where rainwater or water droplets gets splashed
• Location with splashes of water, oil, and chemicals, etc.
• Locations with much dust, salt, and iron powder
• Location with blockers
The G3RV may rupture if short-circuit current flows.
As protection against accidents due to short-circuiting,
be sure to install protective devices, such as fuses and
no-fuse breakers, on the power supply side.
Minor electrical shock may occasionally occur.
Do not touch the main circuit terminals on the G3RV
immediately after the power supply has been turned
OFF.
Shock may result due to the electrical charge stored
in the built-in snubber circuit.
Note: G3RV-202S(L), G3RV-SR500/700-A(L) series
models only
• Where static electricity or noise occurs
• Where strong electromagnetic field is generated
• Where there is a risk of exposure to radioactivity
• Do not use or store Sockets in environments that contain silicone
gas, sulfidizing gas (e.g., SO2 or H2S), or organic gas, or near
materials that contain silicone. Doing so may cause the contacts to
be unstable or to fail.
Handling
• Keep the G3RV well ventilated.
There is a risk of short-circuiting or burning due to G3RV
overheating.
G2RV-SR/G3RV-SR
Mounting
• Before you start wiring, please make sure that the socket is
• Please insert the flat-blade screwdriver to the bottom of the hole. If
• Do not use or store the product in the following locations. Doing so
may result in damage, malfunction, or deterioration of performance
characteristics.
you do not insert the flat-blade screwdriver correctly, the cable will
• Where vibration or shock is directly transmitted to the body
not be connected correctly.
• Do not use the product where the socket could touch a solvent
• When lubricant such as oil is attached to the tip of the driver, the
driver will fall off, with a risk of injury towards the workers.
G2RV-SR
securely attached to the mounting rail. If the socket is unstable, it
may come loose with a risk of injury towards the workers.
Precautions for Correct Use
or alkaline agent.
• Do not insert short bar in the hole for wire or screw driver, it may
cause the result of failure of pull out.
Usage
• Please select the load within the rated range. Doing so may result
If insert short bar in the hole for wire or screw driver and try to pull
out, it may cause damage for short bar or socket.
in damage, malfunction, or failure.
• Please use the power of the rated frequency. It may cause
malfunction, failure, or risk of burnout.
Push-In Plus Terminal Block
1. Connecting Wires to the Push-In Plus Terminal Block
Part Names of the Terminal Block
• Install G3RV according to instructions Mounting on page 23. If you
lead to short-circuiting or burning the output element.
G3RV-SR
install in the wrong direction, abnormal heat is generated, and may
Release hole
• G3RV is an SSR that generates heat. Please observe the ambient
Terminal (Insertion) hole
temperature setting range of G3RV. If installing in an enclosed
space, set a fan, and ventilate.
• When mounting G3RV to DIN rail, firmly fit it into the groove. If it is
Connecting Wires with Ferrules
Insert the ferrule straight into the terminal block until the end strikes
the terminal block.
not properly installed, there is a risk of it falling.
Wiring
• For the current to be applied, make sure a wire size with margin is used.
Otherwise, excessive heat generated by the wires may cause burning.
• Do not attempt to use the wire if the coat is torn. Not doing so may
Release hole
• Always turn OFF the power supply before performing wiring. Not
Ferrules
doing so may cause electrical shock.
• The wires of the socket for G3RV socket should not be passed
through the same duct as that being connected to the high-voltage
power supply. Otherwise, inductive noise may damage the G3RV
or cause it to malfunction.
Push-In Plus Terminal Block
• Do not wire anything to the release holes.
• Do not tilt or twist a flat-blade screwdriver while it is inserted into a release
hole on the terminal block. The terminal block may be damaged.
Connecting Stranded Wires
Use the following procedure to connect the wires to the terminal block.
(1) Hold a flat-blade screwdriver at an angle and insert it into the
release hole.
The angle should be between 10°and15°. If the flat-blade
screwdriver is inserted correctly, you will feel the spring in the
release hole respond.
(2) With the flat-blade screwdriver still inserted into the release hole,
insert the wire into the terminal hole until it strikes the terminal
block.
(3) Remove the flat-blade screwdriver from the release hole.
• Insert a flat-blade screwdriver into the release holes at an angle.
The terminal block may be damaged if you insert the screwdriver
(1)
(3)
Common Precautions
Terminal
(Insertion) hole
result in electric shock.
Flat-blade screwdriver
straight in.
10 to 15°
into a release hole.
(2)
Stranded Wires
(2)
• Do not bend the wire past its natural bending radius or pull on it
with excessive force. Doing so may cause the wire disconnection.
• Do not insert more than one wire into each terminal (insertion) hole.
• To prevent wiring materials from smoking or ignition, use the wiring
(3)
(1)
Checking Connections
• After insertion, pull gently on the wire to make sure that it will not
come out (i.e., to confirm that it is held by the terminal block).
• To prevent short circuits, insert the stripped part of a stranded
materials given in the following table.
Stripping length
Recommended Wire
Ferrules
When using
terminal
Ferrules
When not using
terminal
0.5 to 1.5 mm2/AWG20 to AWG16
10 mm
8 mm
Note: Use Ferrules with UL certification (R/C).
wire or the conductive part of a ferrule until it is hidden inside the
terminal insertion hole. (See following diagram.)
Common Accessories
• Do not allow the flat-blade screwdriver to fall out while it is inserted
Disposal
• Do not dispose of the product by burning.
21
G2RV-SR/G3RV-SR
G2RV-SR
2. Removing Wires from the Push-In Plus Terminal Block
Screw Terminal
Use the following procedure to remove wires from the terminal block.
The same method is used to remove stranded wires and ferrules.
• Screw terminal
Applicable wire
size
Wired type
(1) Hold a flat-blade screwdriver at an angle and insert it into the
release hole.
(2) With the flat-blade screwdriver still inserted into the release hole,
remove the wire from the terminal insertion hole.
(3) Remove the flat-blade screwdriver from the release hole.
(3)
(1)
Flat-blade screwdriver
10 to 15°
Stripping
length
Stranded wires, without
ferrule
0.5 to 1.5 mm2
8 mm
Stranded wires, with ferrule
and plastic collar
0.5 to 1.5 mm2
8 mm
Stranded wires with ferrule,
without plastic collar
0.5 to 1.5 mm2
8 mm
(3)
(1)
(2)
(2)
Wire
• Tightening Torque
0.4 N · m
• Electric wiring
3. Recommended ferrules and tools
Recommended Ferrules
Applicable
wire
Use the electric wire of specified size as shown above. The
stripped wire length is 8 mm.
Recommended ferrules
G3RV-SR
Ferrules
Conduct
length
(mm2) (AWG)
(mm)
Phoenix
Contact
product
Weidmuller
product
Wago product
0.5
20
8
AI0.5-8
H0.5/14
FE-0.5-8N-WH
0.75
18
8
AI0.75-8
H0.75/14
FE-0.75-8N-GY
1
18
8
AI1-8
H1.0/14
FE-1.0-8N-RD
1.5
16
8
AI1.5-8
H1.5/14
FE-1.5-8N-BK
CRIMPFOX6
CRIMPFOX6T-F
CRIMPFOX10S
PZ6 roto
Variocrimp4
Recommended crimp
tool
Screw terminal
Common Precautions
*1. Make sure that the outer diameter of the wire is smaller than the
inner diameter of the insulating sleeve of the recommended
ferrule.
*2. Make sure that the ferrule processing dimensions conform to the
following figure.
8 mm
Stripping length
Operating latching lever
When operating the latching lever for G2RV-SR701/501
series, use a 2.5 mm width flat-blade screwdriver.
• Applicable flat-blade screwdriver
Flat-blade screwdriver with parallel cutting edge: shaft diameter
2.5 mm (3.0 mm max.)
Parallel cutting edge flat-blade screwdriver
8 mm
Shaft diameter 2.5 mm (3.0 mm max.)
Wide flat-blade screwdriver
8 mm
2.1 mm max.
Recommended Flat-blade Screwdriver
Use a flat-blade screwdriver to connect and remove wires.
Use the following flat-blade screwdriver.
The following table is the manufacturer and format at the time in
December 2015.
• Return to its original state after using the latching lever.
• Do not use the latching lever as a switch.
• Operation durability of the latching lever is 100 times or more.
Side
Front
• Do not keep the latching lever ON for a long period of time (24
2.5 mm dia.
Common Accessories
22
Driver with a thick shaft cannot be used.
• Always turn OFF the power supply before operating latching lever.
0.4 mm
hours or more) in order to maintain the operation check function.
2.5 mm
Model
Manufacturer
XW4Z-00B
Omron
ESD0.40×2.5
Wera
SZF 0.4×2.5
Phoenix Contact
0.4×2.5×75 302
Wiha
AEF.2.5×75
Facom
210-719
Wago
SDI 0.4×2.5×75
Weidmuller
G2RV-SR/G3RV-SR
Incorrect Example
Countermeasure 1
Vertical
Direction
Mounting surface
Mounting surface
Open protective cover
Height of SSR
Duct or other object
blocking airflow
Airflow
Metal
base
SSR
Duct or other object
blocking airflow
Use ducts that have a
shallow depth, to provide a
sufficient ventilation area.
Duct or other object
blocking airflow
If the ducts cannot be made lower,
place the SSR on a metal base so
that it is not surrounded by the ducts.
G3RV-SR
Keep the protective cover open when using the latching lever. Move
until the latching lever clicks to the ON position (ON state). After
using the latching lever, in order to prevent malfunction, return the
switch to contact normal position (OFF state), and make sure the
protective cover is firmly closed.
Duct or other object
blocking airflow
SSR
SSR
Do not enclose the SSR in a
duct of the same height.
It will interfere with the heat
dissipation of SSR.
Duct or
other object
blocking
airflow
G2RV-SR
Contact operating position (on-state)
Close protective cover
Countermeasure 2
Recommended height of the duct is
1/2 or less of the height of the SSR
Duct or other object
blocking airflow
Contact normal position
Mounting surface
Method of operation of the latching lever
Be aware of airflow
Duct or other object
blocking airflow
Using the latching lever
Exhaust
(Axial fan)
Example: check the operation of the relay and the sequence circuit
SSR
SSR
SSR
• Since the G3RV uses electronic components, do not allow it to fall,
vibrate, or apply shock that exceeds the criteria. Doing so may
result in failure, malfunction, or deterioration of performance.
• Tighten screw terminal for G3RV with a torque of 0.4 N · m. It may
cause short-circuit failure or burning.
terminal portion of G3RV. It may cause short-circuit failure or
burning.
• If the air inlet or air outlet has a filter, clean the filter regularly to
Common Precautions
• Please use the voltage and current suitable for the input and output
Inlet
prevent it from clogging to ensure an efficient flow of air.
• Do not place objects that may obstruct the proper ventilation for
outside or inside the inlet or exhaust port, and in the outside
Mounting
vicinity.
Duct or other object blocking airflow
• A heat exchanger, if used, should be located in front of the G3RV
to ensure the efficiency of the heat exchanger.
• Please observe the ambient temperature of G3RV. The rated
current of the G3RV is measured at an ambient temperature of
SSR
10 mm min.
60 mm min.
25°C.
• The G3RV uses a semiconductor in the output element.
This causes the temperature inside the control panel to increase
due to heating resulting from the flow of electrical current through
Vertical Direction
the load. The G3RV reliability can be increased by adding a
ventilation fan to the control panel to dispel this heat, thus lowering
the ambient temperature of the G3RV.
(It suggests that life expectancy is doubled by each 10°C reduction
in ambient temperature.)
EMI
The G3RV is a Class A product (for industrial environments).
When used in a residential environment, it may cause radio
interference. In such case, the user may be required to take
appropriate measures.
* When five or more are installed, install with 10 mm space between
each.
Common Accessories
30 mm min.
80 mm min.
23
G2RV-SR/G3RV-SR
For G2RV-SR/G3VR-SR
G2RV-SR
Common Accessories (order separately)
Ordering Information
Short Bars
Appearance
No. of
poles
Pitch
6.2 mm
Colors
Model *
2
PYDN-6.2-020@
3
PYDN-6.2-030@
Red (R),
Blue (S),
Yellow (Y)
4
10
20
Maximum
energizing
current
Minimum order
(Quantity)
PYDN-6.2-040@
10
32 A
PYDN-6.2-100@
PYDN-6.2-200@
Note: Use for wiring to the adjacent socket.
* Replace the box (@) in the model number with the code for the covering color. @ color selection: R = red, S = blue, Y = yellow
G3RV-SR
Labels
Appearance
Minimum order
Model
5 sheets
(1 sheet/72 pieces)
XW5Z-P2.5LB2
Separate Plate
Appearance
Model
Common Precautions
XW5Z-EP12
PLC interface unit
Appearance
I/O classification
Common process
PNP
For input
NPN
PNP
For output
NPN
Connection method
Model
Push-In
P2RVC-8-I-5-1
Screw
P2RVC-8-I-7-1
Push-In
P2RVC-8-I-5
Push-In
P2RVC-8-O-5-1
Screw
P2RVC-8-O-7-1
Push-In
P2RVC-8-O-5
Common Accessories
Parts for DIN Track Mounting
Appearance
Type
Model
1m
PFP-100N
DIN Tracks
–
0.5 m
PFP-50N
End Plate*
PFP-M
Spacer
PFP-S
* When mounting components to DIN rail, prevent sliding using end plates (Model PFP-M).
Refer to your OMRON website for details on PFP-@.
24
Minimum order
(Quantity)
10
G2RV-SR/G3RV-SR
● Applicable Cables
Appearance
End A
Cables with Loose
Wires
P2RV-A@C
8 I/O
points
Device
end
P2RV-A100C
2,000
P2RV-A200C
3,000
P2RV-A300C
5,000
P2RV-A500C
1,000
P2RV-4-100C
2,000
P2RV-4-200C
3,000
P2RV-4-300C
5,000
P2RV-4-500C
1,000
P2RV-4-100IMC
2,000
P2RV-4-200IMC
32 input
points
300
P2RV-4-300IMC
5,000
P2RV-4-500IMC
1,000
P2RV-4-100IFC
2,000
P2RV-4-200IFC
300
L
8 output
points
8 input
points
L
3,000
P2RV-4-300IFC
5,000
P2RV-4-500IFC
500
P2RV-A050C-OMR GRT1
1,000
P2RV-A100C-OMR GRT1
500
P2RV-A050IC-OMR GRT1
1,000
P2RV-A100IC-OMR GRT1
P2RV-A050C-OMR NX
1,000
P2RV-A100C-OMR NX
500
P2RV-A050IC-OMR NX
1,000
P2RV-A100IC-OMR NX
PLC I/O Units with MIL connectors (1:4)
CJ1W-ID232/ID262, etc.
PLC I/O Units with Fujitsu connectors (1:4)
CJ1W-ID231/ID261, etc.
Slice I/O Units (1:1)
For inputs: GRT1-ID8-1
For outputs: GRT1-OD8-1
PLC I/O Units with MIL connectors (1:1)
For inputs: NX-ID4442
For outputs: NX-OD4256
Common Accessories
500
PLC I/O Units with MIL connectors (1:4)
CJ1W-OD232/OD262, etc.
Common Precautions
3,000
32 input
points
8 output
Cables with Connectors points
(1:1)
P2RV-A@C-OMR GRT1 8 input
points
Applicable Connectors
G3RV-SR
300
L
Cables with
Connectors (1:1)
P2RV-A@C-OMR NX
1,000
32 output
points
L
Cables with
Connectors (1:4)
P2RV-4-@IFC
End B
PLC interface
unit end
L
L
Cables with
Connectors (1:4)
P2RV-4-@IMC
Connecting Cables
Various devices
70
Cables with
Connectors (1:4)
P2RV-4-@C
Cable
length L
(mm)
G2RV-SR
Name
25
G2RV-SR/G3RV-SR
Name
Appearance
G2RV-SR
End A
32 input
points
End B
Device
end
PLC interface
unit end
32 output
points
Schneider Electric
PLC Connecting
Cables
P2RV-@C-SCH-@
L
300
G3RV-SR
16 input
points
16 output
points
L
300
32 input
points
Common Precautions
Common Accessories
26
32 output
points
Siemens PLC
Connecting Cables
P2RV-@C-SIM-@
L
300
16 input
points
L
300
32 input
points
32 output
points
L
300
Cable
length L
(mm)
Connecting Cables
500
P2RV-050C-SCH-A
1,000
P2RV-100C-SCH-A
2,000
P2RV-200C-SCH-A
3,000
P2RV-300C-SCH-A
5,000
P2RV-500C-SCH-A
500
P2RV-050C-SCH-B
1,000
P2RV-100C-SCH-B
2,000
P2RV-200C-SCH-B
3,000
P2RV-300C-SCH-B
5,000
P2RV-500C-SCH-B
500
P2RV-050C-SCH-C
1,000
P2RV-100C-SCH-C
2,000
P2RV-200C-SCH-C
3,000
P2RV-300C-SCH-C
5,000
P2RV-500C-SCH-C
500
P2RV-050C-SCH-D
1,000
P2RV-100C-SCH-D
2,000
P2RV-200C-SCH-D
3,000
P2RV-300C-SCH-D
5,000
P2RV-500C-SCH-D
500
P2RV-050C-SIM-A
1,000
P2RV-100C-SIM-A
2,000
P2RV-200C-SIM-A
3,000
P2RV-300C-SIM-A
5,000
P2RV-500C-SIM-A
500
P2RV-050C-SIM-B
1,000
P2RV-100C-SIM-B
2,000
P2RV-200C-SIM-B
3,000
P2RV-300C-SIM-B
5,000
P2RV-500C-SIM-B
500
P2RV-050C-SIM-C
1,000
P2RV-100C-SIM-C
2,000
P2RV-200C-SIM-C
3,000
P2RV-300C-SIM-C
5,000
P2RV-500C-SIM-C
500
P2RV-050C-SIM-D
1,000
P2RV-100C-SIM-D
2,000
P2RV-200C-SIM-D
3,000
P2RV-300C-SIM-D
5,000
P2RV-500C-SIM-D
500
P2RV-050C-SIM-E
1,000
P2RV-100C-SIM-E
2,000
P2RV-200C-SIM-E
3,000
P2RV-300C-SIM-E
5,000
P2RV-500C-SIM-E
Applicable Connectors
Schneider Electric PLCs with 32-point
connectors (1:4)
For inputs: 140 DDI 353 00
For outputs: 140 DDO 353 00
Schneider Electric PLCs with
16-point connectors (1:2)
For inputs: BMX DDI 1602
For outputs: BMX DDO 1602
Siemens PLCs with
32-point connectors (1:4)
For inputs: 6ES7 321-1BL00-0AA0
For outputs: 6ES7 322-1BL00-0AA0
Siemens PLCs with
16-point connectors (1:2)
For inputs: 6ES7 321-1BH02-0AA0
Siemens PLCs with
32-point connectors (1:4)
For inputs: 6ES7 421-1BL-0AA0
For outputs: 6ES7 422-1BL-0AA0
G2RV-SR/G3RV-SR
PLC interface unit
G2RV-SR
Ratings / characteristics
Rated voltage
30 VAC/DC
Rated current
0.5 A/poles, 2 A/unit
Ambient operating
temperature
−40 to 55°C
Electrical schematic
Input
P2RVC-8-I-@-1 (PNP)
1....................8
14
P2RVC-8-I-5 (NPN)
1....................8
14
11
11
G3RV-SR
1 3 5 7 9
2 4 6 8 10
1....................8
P2RVC-8-O-5 (NPN)
1....................8
A2
A2
A1
1 3 5 7 9
2 4 6 8 10
A1
1 3 5 7 9
2 4 6 8 10
Common Precautions
Output
P2RVC-8-O-@-1 (PNP)
1 3 5 7 9
2 4 6 8 10
Common Accessories
27
G2RV-SR/G3RV-SR
Dimensions
(unit: mm)
PLC interface unit
G2RV-SR
Push-IN
P2RVC-8-I-5(-1)
P2RVC-8-O-5(-1)
49.60
67.16
G3RV-SR
Common Precautions
Common Accessories
28
12.68
7×6.20
29
Screw
P2RVC-8-I-7-1
P2RVC-8-O-7-1
49.60
67.16
12.68
7×6.20
29
G2RV-SR/G3RV-SR
(Except for PLC interface unit)
Common Accessories
(unit: mm)
Short Bars
PYDN-6.2-@@ (6.2 mm)
2
L
Pitch
No. of poles
1.20
6.2 mm
9
6.20
14
L (Length)
Colors
Model *
2
12.4
PYDN-6.2-020@
3
18.6
PYDN-6.2-030@
4
24.8
10
62
20
124
Red (R)
Blue (S)
Yellow (Y)
Maximum carry
current
PYDN-6.2-040@
G2RV-SR
Dimensions
32 A
PYDN-6.2-100@
PYDN-6.2-200@
Note: Use the Short Bars for crossover wiring within one Socket or between Sockets.
* Replace the box (@) in the model number with the code for the covering color.
Separate Plate
12
56
G3RV-SR
XW5Z-EP12
63
Refer to your OMRON website for details on the PFP-@.
Common Precautions
Parts for DIN Track Mounting
Common Accessories
29
Terms and Conditions of Sale
1. Offer; Acceptance. These terms and conditions (these "Terms") are deemed
part of all quotes, agreements, purchase orders, acknowledgments, price lists,
catalogs, manuals, brochures and other documents, whether electronic or in
writing, relating to the sale of products or services (collectively, the "Products")
by Omron Electronics LLC and its subsidiary companies (“Omron”). Omron
objects to any terms or conditions proposed in Buyer’s purchase order or other
documents which are inconsistent with, or in addition to, these Terms.
2. Prices; Payment Terms. All prices stated are current, subject to change without notice by Omron. Omron reserves the right to increase or decrease prices
on any unshipped portions of outstanding orders. Payments for Products are
due net 30 days unless otherwise stated in the invoice.
3. Discounts. Cash discounts, if any, will apply only on the net amount of invoices
sent to Buyer after deducting transportation charges, taxes and duties, and will
be allowed only if (i) the invoice is paid according to Omron’s payment terms
and (ii) Buyer has no past due amounts.
4. Interest. Omron, at its option, may charge Buyer 1-1/2% interest per month or
the maximum legal rate, whichever is less, on any balance not paid within the
stated terms.
5. Orders. Omron will accept no order less than $200 net billing.
6. Governmental Approvals. Buyer shall be responsible for, and shall bear all
costs involved in, obtaining any government approvals required for the importation or sale of the Products.
7. Taxes. All taxes, duties and other governmental charges (other than general
real property and income taxes), including any interest or penalties thereon,
imposed directly or indirectly on Omron or required to be collected directly or
indirectly by Omron for the manufacture, production, sale, delivery, importation, consumption or use of the Products sold hereunder (including customs
duties and sales, excise, use, turnover and license taxes) shall be charged to
and remitted by Buyer to Omron.
8. Financial. If the financial position of Buyer at any time becomes unsatisfactory
to Omron, Omron reserves the right to stop shipments or require satisfactory
security or payment in advance. If Buyer fails to make payment or otherwise
comply with these Terms or any related agreement, Omron may (without liability and in addition to other remedies) cancel any unshipped portion of Products sold hereunder and stop any Products in transit until Buyer pays all
amounts, including amounts payable hereunder, whether or not then due,
which are owing to it by Buyer. Buyer shall in any event remain liable for all
unpaid accounts.
9. Cancellation; Etc. Orders are not subject to rescheduling or cancellation
unless Buyer indemnifies Omron against all related costs or expenses.
10. Force Majeure. Omron shall not be liable for any delay or failure in delivery
resulting from causes beyond its control, including earthquakes, fires, floods,
strikes or other labor disputes, shortage of labor or materials, accidents to
machinery, acts of sabotage, riots, delay in or lack of transportation or the
requirements of any government authority.
11. Shipping; Delivery. Unless otherwise expressly agreed in writing by Omron:
a. Shipments shall be by a carrier selected by Omron; Omron will not drop ship
except in “break down” situations.
b. Such carrier shall act as the agent of Buyer and delivery to such carrier shall
constitute delivery to Buyer;
c. All sales and shipments of Products shall be FOB shipping point (unless otherwise stated in writing by Omron), at which point title and risk of loss shall
pass from Omron to Buyer; provided that Omron shall retain a security interest in the Products until the full purchase price is paid;
d. Delivery and shipping dates are estimates only; and
e. Omron will package Products as it deems proper for protection against normal handling and extra charges apply to special conditions.
12. Claims. Any claim by Buyer against Omron for shortage or damage to the
Products occurring before delivery to the carrier must be presented in writing
to Omron within 30 days of receipt of shipment and include the original transportation bill signed by the carrier noting that the carrier received the Products
from Omron in the condition claimed.
13. Warranties. (a) Exclusive Warranty. Omron’s exclusive warranty is that the
Products will be free from defects in materials and workmanship for a period of
twelve months from the date of sale by Omron (or such other period expressed
in writing by Omron). Omron disclaims all other warranties, express or implied.
(b) Limitations. OMRON MAKES NO WARRANTY OR REPRESENTATION,
EXPRESS OR IMPLIED, ABOUT NON-INFRINGEMENT, MERCHANTABIL-
14.
15.
16.
17.
18.
ITY OR FITNESS FOR A PARTICULAR PURPOSE OF THE PRODUCTS.
BUYER ACKNOWLEDGES THAT IT ALONE HAS DETERMINED THAT THE
PRODUCTS WILL SUITABLY MEET THE REQUIREMENTS OF THEIR
INTENDED USE. Omron further disclaims all warranties and responsibility of
any type for claims or expenses based on infringement by the Products or otherwise of any intellectual property right. (c) Buyer Remedy. Omron’s sole obligation hereunder shall be, at Omron’s election, to (i) replace (in the form
originally shipped with Buyer responsible for labor charges for removal or
replacement thereof) the non-complying Product, (ii) repair the non-complying
Product, or (iii) repay or credit Buyer an amount equal to the purchase price of
the non-complying Product; provided that in no event shall Omron be responsible for warranty, repair, indemnity or any other claims or expenses regarding
the Products unless Omron’s analysis confirms that the Products were properly handled, stored, installed and maintained and not subject to contamination, abuse, misuse or inappropriate modification. Return of any Products by
Buyer must be approved in writing by Omron before shipment. Omron Companies shall not be liable for the suitability or unsuitability or the results from the
use of Products in combination with any electrical or electronic components,
circuits, system assemblies or any other materials or substances or environments. Any advice, recommendations or information given orally or in writing,
are not to be construed as an amendment or addition to the above warranty.
See http://www.omron247.com or contact your Omron representative for published information.
Limitation on Liability; Etc. OMRON COMPANIES SHALL NOT BE LIABLE
FOR SPECIAL, INDIRECT, INCIDENTAL, OR CONSEQUENTIAL DAMAGES,
LOSS OF PROFITS OR PRODUCTION OR COMMERCIAL LOSS IN ANY
WAY CONNECTED WITH THE PRODUCTS, WHETHER SUCH CLAIM IS
BASED IN CONTRACT, WARRANTY, NEGLIGENCE OR STRICT LIABILITY.
Further, in no event shall liability of Omron Companies exceed the individual
price of the Product on which liability is asserted.
Indemnities. Buyer shall indemnify and hold harmless Omron Companies and
their employees from and against all liabilities, losses, claims, costs and
expenses (including attorney's fees and expenses) related to any claim, investigation, litigation or proceeding (whether or not Omron is a party) which arises
or is alleged to arise from Buyer's acts or omissions under these Terms or in
any way with respect to the Products. Without limiting the foregoing, Buyer (at
its own expense) shall indemnify and hold harmless Omron and defend or settle any action brought against such Companies to the extent based on a claim
that any Product made to Buyer specifications infringed intellectual property
rights of another party.
Property; Confidentiality. Any intellectual property in the Products is the exclusive property of Omron Companies and Buyer shall not attempt to duplicate it
in any way without the written permission of Omron. Notwithstanding any
charges to Buyer for engineering or tooling, all engineering and tooling shall
remain the exclusive property of Omron. All information and materials supplied
by Omron to Buyer relating to the Products are confidential and proprietary,
and Buyer shall limit distribution thereof to its trusted employees and strictly
prevent disclosure to any third party.
Export Controls. Buyer shall comply with all applicable laws, regulations and
licenses regarding (i) export of products or information; (iii) sale of products to
“forbidden” or other proscribed persons; and (ii) disclosure to non-citizens of
regulated technology or information.
Miscellaneous. (a) Waiver. No failure or delay by Omron in exercising any right
and no course of dealing between Buyer and Omron shall operate as a waiver
of rights by Omron. (b) Assignment. Buyer may not assign its rights hereunder
without Omron's written consent. (c) Law. These Terms are governed by the
law of the jurisdiction of the home office of the Omron company from which
Buyer is purchasing the Products (without regard to conflict of law principles). (d) Amendment. These Terms constitute the entire agreement between
Buyer and Omron relating to the Products, and no provision may be changed
or waived unless in writing signed by the parties. (e) Severability. If any provision hereof is rendered ineffective or invalid, such provision shall not invalidate
any other provision. (f) Setoff. Buyer shall have no right to set off any amounts
against the amount owing in respect of this invoice. (g) Definitions. As used
herein, “including” means “including without limitation”; and “Omron Companies” (or similar words) mean Omron Corporation and any direct or indirect
subsidiary or affiliate thereof.
Certain Precautions on Specifications and Use
1. Suitability of Use. Omron Companies shall not be responsible for conformity
with any standards, codes or regulations which apply to the combination of the
Product in the Buyer’s application or use of the Product. At Buyer’s request,
Omron will provide applicable third party certification documents identifying
ratings and limitations of use which apply to the Product. This information by
itself is not sufficient for a complete determination of the suitability of the Product in combination with the end product, machine, system, or other application
or use. Buyer shall be solely responsible for determining appropriateness of
the particular Product with respect to Buyer’s application, product or system.
Buyer shall take application responsibility in all cases but the following is a
non-exhaustive list of applications for which particular attention must be given:
(i) Outdoor use, uses involving potential chemical contamination or electrical
interference, or conditions or uses not described in this document.
(ii) Use in consumer products or any use in significant quantities.
(iii) Energy control systems, combustion systems, railroad systems, aviation
systems, medical equipment, amusement machines, vehicles, safety equipment, and installations subject to separate industry or government regulations.
(iv) Systems, machines and equipment that could present a risk to life or property. Please know and observe all prohibitions of use applicable to this Product.
NEVER USE THE PRODUCT FOR AN APPLICATION INVOLVING SERIOUS
RISK TO LIFE OR PROPERTY OR IN LARGE QUANTITIES WITHOUT
ENSURING THAT THE SYSTEM AS A WHOLE HAS BEEN DESIGNED TO
2.
3.
4.
5.
ADDRESS THE RISKS, AND THAT THE OMRON’S PRODUCT IS PROPERLY RATED AND INSTALLED FOR THE INTENDED USE WITHIN THE
OVERALL EQUIPMENT OR SYSTEM.
Programmable Products. Omron Companies shall not be responsible for the
user’s programming of a programmable Product, or any consequence thereof.
Performance Data. Data presented in Omron Company websites, catalogs
and other materials is provided as a guide for the user in determining suitability and does not constitute a warranty. It may represent the result of Omron’s
test conditions, and the user must correlate it to actual application requirements. Actual performance is subject to the Omron’s Warranty and Limitations
of Liability.
Change in Specifications. Product specifications and accessories may be
changed at any time based on improvements and other reasons. It is our practice to change part numbers when published ratings or features are changed,
or when significant construction changes are made. However, some specifications of the Product may be changed without any notice. When in doubt, special part numbers may be assigned to fix or establish key specifications for
your application. Please consult with your Omron’s representative at any time
to confirm actual specifications of purchased Product.
Errors and Omissions. Information presented by Omron Companies has been
checked and is believed to be accurate; however, no responsibility is assumed
for clerical, typographical or proofreading errors or omissions.
OMRON AUTOMATION AMERICAS HEADQUARTERS • Chicago, IL USA • 847.843.7900 • 800.556.6766 • www.omron247.com
OMRON CANADA, INC. • HEAD OFFICE
Toronto, ON, Canada • 416.286.6465 • 866.986.6766 • www.omron247.com
OMRON ARGENTINA • SALES OFFICE
Cono Sur • 54.11.4783.5300
OMRON ELECTRONICS DE MEXICO • HEAD OFFICE
México DF • 52.55.59.01.43.00 • 01-800-226-6766 • mela@omron.com
OMRON CHILE • SALES OFFICE
Santiago • 56.9.9917.3920
OMRON ELECTRONICS DE MEXICO • SALES OFFICE
Apodaca, N.L. • 52.81.11.56.99.20 • 01-800-226-6766 • mela@omron.com
OTHER OMRON LATIN AMERICA SALES
54.11.4783.5300
OMRON ELETRÔNICA DO BRASIL LTDA • HEAD OFFICE
São Paulo, SP, Brasil • 55.11.2101.6300 • www.omron.com.br
OMRON EUROPE B.V. • Wegalaan 67-69, NL-2132 JD, Hoofddorp, The Netherlands. • +31 (0) 23 568 13 00 • www.industrial.omron.eu
Controllers & I/O
• Machine Automation Controllers (MAC) • Motion Controllers
• Programmable Logic Controllers (PLC) • Temperature Controllers • Remote I/O
Authorized Distributor:
Robotics
• Industrial Robots • Mobile Robots
Operator Interfaces
• Human Machine Interface (HMI)
Motion & Drives
• Machine Automation Controllers (MAC) • Motion Controllers • Servo Systems
• Frequency Inverters
Vision, Measurement & Identification
• Vision Sensors & Systems • Measurement Sensors • Auto Identification Systems
Sensing
• Photoelectric Sensors • Fiber-Optic Sensors • Proximity Sensors
• Rotary Encoders • Ultrasonic Sensors
Safety
• Safety Light Curtains • Safety Laser Scanners • Programmable Safety Systems
• Safety Mats and Edges • Safety Door Switches • Emergency Stop Devices
• Safety Switches & Operator Controls • Safety Monitoring/Force-guided Relays
Control Components
• Power Supplies • Timers • Counters • Programmable Relays
• Digital Panel Meters • Monitoring Products
Switches & Relays
• Limit Switches • Pushbutton Switches • Electromechanical Relays
• Solid State Relays
Software
• Programming & Configuration • Runtime
J285I-E-01
06/16
Note: Specifications are subject to change.
© 2016 Omron. All Rights Reserved.
Printed on recycled paper.
Printed in U.S.A.
Mouser Electronics
Authorized Distributor
Click to View Pricing, Inventory, Delivery & Lifecycle Information:
Omron:
G2RV-1-S DC21 G2RV-1-S DC48 G2RV-1-S DC11 G3RV-202S DC12 G3RV-202S DC24 G3RV-202S DC48
G3RV-202SL DC12 G3RV-202SL DC24 G3RV-202SL DC48 G3RV-D03SL DC12 G3RV-D03SL DC24 G3RV-D03SL
DC48 G3RV-SL500-A AC/DC48 G3RV-SL500-A AC110 G3RV-SL500-A AC230 G3RV-SL500-A DC12 G3RV-SL500A DC24 G3RV-SL500-AL AC230 G3RV-SL500-AL DC24 G3RV-SL500-D AC110 G3RV-SL500-D AC230 G3RVSL500-D DC12 G3RV-SL500-D DC24 G3RV-SL700-A AC/DC48 G3RV-SL700-A AC110 G3RV-SL700-A AC230
G3RV-SL700-A DC12 G3RV-SL700-A DC24 G3RV-SL700-AL AC110 G3RV-SL700-AL AC230 G3RV-SL700-AL
DC24 G3RV-SL700-D AC/DC48 G3RV-SL700-D AC110 G3RV-SL700-D AC230 G3RV-SL700-D DC12 G3RVSL700-D DC24 G3RV-SL500-A AC/DC24 G3RV-SL500-AL AC110 G3RV-SL500-AL AC/DC24 G3RV-SL500-AL
AC/DC48 G3RV-SL500-AL DC12 G3RV-SL500-D AC/DC24 G3RV-SL500-D AC/DC48 G3RV-SL700-A AC/DC24
G3RV-SL700-AL AC/DC24 G3RV-SL700-AL AC/DC48 G3RV-SL700-AL DC12 G3RV-SL700-D AC/DC24 G2RVSL700-AP AC230 G2RV-SL500-AP DC12 G2RV-SL500-AP AC230 G2RV-SL500-AP DC24 G2RV-SL500-AP AC110
G2RV-SL500-AP AC/DC24 G2RV-SL700-AP DC12 G2RV-SL700-AP AC110 G2RV-SL500-AP AC/DC48 G2RVSL700-AP AC/DC48 G2RV-SL700-AP AC/DC24 G2RV-SL700-AP DC24 G2RV-SL700-AC/DC48 G2RV-SL700-DC12
G2RV-SL700 AC230 G2RV-SL500 AC/DC48 G2RV-SL700-DC24 G2RV-SL500 AC110 G2RV-SL700-AC110
G2RV-SL500 DC12(DC11) G2RV-SL700-AC/DC24 G2RV-SL500 AC230 G2RV-SL500 AC/DC24 G2RV-1-S-AP
DC11 G2RV-1-S-AP DC48 G2RV-1-S-AP DC21 G2RV-SL700 DC12(DC11) G2RV-SL700 DC24(DC21) G2RVSR500-AP ACDC24 PYDN-6.2-200S PYDN-6.2-020R PYDN-6.2-020S PYDN-6.2-020Y PYDN-6.2-030R PYDN-6.2030S PYDN-6.2-030Y G3RV-SR500-AL AC/DC24 G3RV-SR500-AL AC/DC48 G3RV-SR700-AL AC/DC24 G3RVSR700-AL AC/DC48 PYDN-6.2-200R PYDN-6.2-200Y G2RV-SR500-AP AC/DC48 G2RV-SR700-AP AC/DC24
G2RV-SR700-AP AC/DC48 PYDN-6.2-040R PYDN-6.2-040S PYDN-6.2-040Y PYDN-6.2-100R PYDN-6.2-100S
PYDN-6.2-100Y G2RV-SL701-AC/DC24