0
登录后你可以
  • 下载海量资料
  • 学习在线课程
  • 观看技术视频
  • 写文章/发帖/加入社区
创作中心
发布
  • 发文章

  • 发资料

  • 发帖

  • 提问

  • 发视频

创作活动
PYF14T

PYF14T

  • 厂商:

    OMRON(欧姆龙)

  • 封装:

    -

  • 描述:

    CONNECTING SOCKET DIN FOR MY

  • 数据手册
  • 价格&库存
PYF14T 数据手册
Screwless Clamp Terminal Socket PYF@@S • Screwless clamping greatly contributes to reducing wiring time. • No over or under tightening of cable connection so better contact reliability is achieved. • Double wiring possible on all the terminals, and easy bridge and branch connections. • Use either solid or stranded wires from 0.2 to 1.5 mm2 (AWG24 to AWG16). • Safe terminal arrangement: Coil terminals separated from contact terminals. • Unique ejector enables easy relay replacement. • Two types of nameplate are available: New MY and Legrand. • Finger-protection construction. Ordering Information ■ List of Models 4-pole 2-pole Socket PYF14S PYF08S Clip & Release Lever PYCM-14S PYCM-08S Nameplate R99-11 nameplate for MY Socket Bridge PYDM-14SR, PYDM-14SB PYDM-08SR, PYDM-08SB Specifications ■ Ratings/Characteristics Item PYF14S Relay PYF08S Remarks MY2 Series MY4 Series MY2 Series --- 23.2 × 85 × 36.5 mm max. (W × H × D) --- Dimensions 31 × 85 × 36.5 mm max. (W × H × D) Rated voltage 250 V AC Rated carry current 10 A at 55°C with MY2 (S) (see note) 5 A at 70°C with MY4 (S) Applicable wires 0.2 to 1.5 mm2 (AWG24 to AWG16) Solid wire Stranded wires --- Number of wire connections 2 wires per terminal (1 wire per hole) --- Clamping force --10 A at 55°C with MY2 (S) 7 A at 70°C with MY2 (S) VDE0627 EN60999 2 10 N min. (0.2 mm ) 40 N min. (1.5 mm2) Note: MY2 (S) can be used at 70°C but at 7 A. ■ Approved Standards Standard File No. VDE0627 (IEC664, EN60999) 112467UG UL508 (UL1059) E87929 Vol. 3 CSA C22.2 No. 14 (CSA C22.2 No. 158) LR31928 Screwless Clamp Terminal Socket PYF@@S 1 Dimensions Note: All units are in millimeters unless otherwise indicated. PYF14S 38.2 max. 36.5 max. PYF08S 36.5 max. 23.2 max. 31 max. 85 max. 85 max. (5.3) Terminal Arrangement PYF14S PYF08S Common contacts Make contacts Break contacts Coils Note: Pole-2 and pole-3 cannot be used with the MY2 type. Use pole-1 (terminal numbers: 11, 14, 12) and pole-4 (terminal numbers: 41, 44, 42). Mounting Height (With Lever) PYF14S PYF08S 72.6 typ. 73.6 typ. 28.6 2 28.6 Screwless Clamp Terminal Socket PYF@@S ■ Accessories (Option) Socket Bridge Insulating coating 9 14 L 1.2 dia. conductor (See note 1.) Note: 1. The relationship between the model number, the length L, and the color of the insulating coating is shown in the following table. Model number PYDM-14SR Length L (mm) 27.5 PYDM-14SB PYDM-08SR Color of insulating coating 3. The positions of the ends of the insulating coating must not vary more than 0.5 mm. 4. The characteristics of the socket bridge are shown in the following table. Item Red Blue 19.7 PYDM-08SB Red Blue Characteristic Rated ON current 10 A Rated insulation voltage 250 VAC Temperature rise 35°C max. Dielectric strength 1,500 VAC for 1 minute Ambient operating temper- –55 to 70°C ature 2. The insulating coating must be able to withstand a voltage of 1,500 V for 1 minute. Use either PE or PA as the material of the insulating coating. Levers PYF14S Lever PYF08S Lever 16 typ. 26.5 typ. 21.5 typ. 28 typ. 6 typ. 54.4 typ. 4.1 typ. 52.5 typ. 5.4 typ. 32.7 typ. 29.6 typ. 3 typ. 6.41 typ. Installation ■ Tools A flat-blade screwdriver should be used to mount the cables. Applicable Screwdriver ● Flat-blade, Parallel-tip, 2.5 mm diameter (3.0 mm max.) ● Flat-blade, Parallel-tip 2.5 dia. (3.0 mm max.) ● Flat-blade, Flared-tip Cannot be used. Examples: FACOM AEF.2.5 × 75E VESSEL No. 9900-(-)2.5 × 75 WAGO 210-119 WIHA 260/2.5 × 40 (AEF. 3 × 75E) (No. 9900-(-)3 × 100) (260/3 × 50) *Chamfering the tip of the driver improves insertion when used as an exclusive tool. Screwless Clamp Terminal Socket PYF@@S 3 ■ Applicable Wires Applicable Wire Sizes 0.2 to 1.5 mm2, AWG24 to AWG16 Applicable Wire Type Solid wires, stranded wires, flexible wires, or wires with ferules can be used. Note: 1. If the overall diameter of the wire is less than 2.2 mm, do not insert the wire past the conductor. Refer to the following diagrams. (See note 1.) < 2.2 ≤ Diameter D (mm) ≤ 3.2 (3.5: see note 2.) Conductor diameter d (mm) or length of sides a and b (mm) ≤ 1.9 2. If the overall diameter of the wire is over 3.2 mm, it will be difficult to use double wiring. Wires with Ferules Examples of Applicable Wires (Confirmed Using Catalog Information) Type of wire Conductor type Equipment wire 2491X Flexible BS6004 Solid Switchgear BS6231 See note 1, above. Recommended wire sizes See note 2, above. 0.5, 0.75, 1.0 mm2 1.5 mm2 Solid 1.0 mm2 1.5 mm2 Switchgear BS6231 Flexible 0.5, 0.75 mm2 1.0 mm2 Tri-rated control and switchgear Flexible 0.5, 0.75, 1.0, 1.5 mm2 Conduit Stranded 1.5 mm2 0.5 mm2 UL1007 Flexible UL1015 Flexible 18AWG UL1061 Flexible 18AWG UL1430 Flexible 18AWG 16AWG 18AWG, 16AWG 16AWG ■ Wiring Use wires of the applicable sizes specified above. The length of the exposed conductor should be 8 to 9 mm. 8 to 9 mm Fig. 1 Exposed Conductor Length 2. Insert the exposed conductor into the wire connection hole. Use the following wiring procedure. 1. Insert the specified screwdriver into the release hole located beside the wire connection hole where the wire is to be inserted. Insert Wire connection holes Release holes 3. Pull out the screwdriver. Fig. 2 Wire Connection Holes and Release Holes Wire connection hole Pull out Release hole Insert Screwdriver Fig. 3 Section A-A of Fig. 2 4 Screwless Clamp Terminal Socket PYF@@S Precautions Precautions for Connection General Precautions • Do not move the screwdriver up, down, or from side to side while it is inserted in the hole. Doing so may cause damage to internal components (e.g., deformation of the coil spring or cracks in the housing) or cause deterioration of insulation. • Do not insert the screwdriver at an angle. Doing so may break the side of socket and result in a short-circuit. • Use the clip to prevent relays floating or falling out of the socket. • Do not use the product if it has been dropped on the ground. Dropping the product may adversely affect performance. • Confirm that the socket is securely attached to the mounting track before wiring. If the socket is mounted insecurely it may fall and injure the operator. • Ensure that the socket is not charged during wiring and maintenance. Not doing so may result in electric shock. • Do not pour water or cleansing agents on the product. Doing so may result in electric shock. • Do not use the socket in locations subject to solvents or alkaline chemicals. • Do not use the socket in locations subject to ultraviolet light (e.g., direct sunlight). Doing so may result in markings fading, rust, corrosion, or resin deterioration. • Do not dispose of the product in fire. • Do not insert two or more wires in the hole. Wires may come in contact with the spring causing a temperature rise or be subject to sparks. (There are two wiring holes for each terminal.) Removing from Mounting Rail To remove the socket from the mounting rail, insert the tip of screwdriver in the fixture rail, and move it in the direction shown below. • Insert the screwdriver along the hole wall as shown below. Screwdriver Fixture rail Screwdriver • If lubricating liquid, such as oil, is present on the tip of screwdriver, the screwdriver may fall out resulting in injury to the operator. • Insert the screwdriver into the bottom of the hole. It may not be possible to connect cables properly if the screwdriver is inserted incorrectly. ALL DIMENSIONS SHOWN ARE IN MILLIMETERS. To convert millimeters into inches, multiply by 0.03937. To convert grams into ounces, multiply by 0.03527. Cat. No. J122-E1-04 In the interest of product improvement, specifications are subject to change without notice. Screwless Clamp Terminal Socket PYF@@S 5 Read and Understand This Catalog Please read and understand this catalog before purchasing the products. Please consult your OMRON representative if you have any questions or comments. Warranty and Limitations of Liability WARRANTY OMRON's exclusive warranty is that the products are free from defects in materials and workmanship for a period of one year (or other period if specified) from date of sale by OMRON. OMRON MAKES NO WARRANTY OR REPRESENTATION, EXPRESS OR IMPLIED, REGARDING NON-INFRINGEMENT, MERCHANTABILITY, OR FITNESS FOR PARTICULAR PURPOSE OF THE PRODUCTS. ANY BUYER OR USER ACKNOWLEDGES THAT THE BUYER OR USER ALONE HAS DETERMINED THAT THE PRODUCTS WILL SUITABLY MEET THE REQUIREMENTS OF THEIR INTENDED USE. OMRON DISCLAIMS ALL OTHER WARRANTIES, EXPRESS OR IMPLIED. LIMITATIONS OF LIABILITY OMRON SHALL NOT BE RESPONSIBLE FOR SPECIAL, INDIRECT, OR CONSEQUENTIAL DAMAGES, LOSS OF PROFITS, OR COMMERCIAL LOSS IN ANY WAY CONNECTED WITH THE PRODUCTS, WHETHER SUCH CLAIM IS BASED ON CONTRACT, WARRANTY, NEGLIGENCE, OR STRICT LIABILITY. In no event shall responsibility of OMRON for any act exceed the individual price of the product on which liability is asserted. IN NO EVENT SHALL OMRON BE RESPONSIBLE FOR WARRANTY, REPAIR, OR OTHER CLAIMS REGARDING THE PRODUCTS UNLESS OMRON'S ANALYSIS CONFIRMS THAT THE PRODUCTS WERE PROPERLY HANDLED, STORED, INSTALLED, AND MAINTAINED AND NOT SUBJECT TO CONTAMINATION, ABUSE, MISUSE, OR INAPPROPRIATE MODIFICATION OR REPAIR. Application Considerations SUITABILITY FOR USE OMRON shall not be responsible for conformity with any standards, codes, or regulations that apply to the combination of products in the customer's application or use of the product. At the customer's request, OMRON will provide applicable third party certification documents identifying ratings and limitations of use that apply to the products. This information by itself is not sufficient for a complete determination of the suitability of the products in combination with the end product, machine, system, or other application or use. The following are some examples of applications for which particular attention must be given. This is not intended to be an exhaustive list of all possible uses of the products, nor is it intended to imply that the uses listed may be suitable for the products: • Outdoor use, uses involving potential chemical contamination or electrical interference, or conditions or uses not described in this catalog. • Nuclear energy control systems, combustion systems, railroad systems, aviation systems, medical equipment, amusement machines, vehicles, safety equipment, and installations subject to separate industry or government regulations. • Systems, machines, and equipment that could present a risk to life or property. Please know and observe all prohibitions of use applicable to the products. NEVER USE THE PRODUCTS FOR AN APPLICATION INVOLVING SERIOUS RISK TO LIFE OR PROPERTY WITHOUT ENSURING THAT THE SYSTEM AS A WHOLE HAS BEEN DESIGNED TO ADDRESS THE RISKS, AND THAT THE OMRON PRODUCT IS PROPERLY RATED AND INSTALLED FOR THE INTENDED USE WITHIN THE OVERALL EQUIPMENT OR SYSTEM. Disclaimers CHANGE IN SPECIFICATIONS Product specifications and accessories may be changed at any time based on improvements and other reasons. It is our practice to change model numbers when published ratings or features are changed, or when significant construction changes are made. However, some specifications of the product may be changed without any notice. When in doubt, special model numbers may be assigned to fix or establish key specifications for your application on your request. Please consult with your OMRON representative at any time to confirm actual specifications of purchased product. DIMENSIONS AND WEIGHTS Dimensions and weights are nominal and are not to be used for manufacturing purposes, even when tolerances are shown. ERRORS AND OMISSIONS The information in this catalog has been carefully checked and is believed to be accurate; however, no responsibility is assumed for clerical, typographical, or proofreading errors, or omissions. PERFORMANCE DATA Performance data given in this catalog is provided as a guide for the user in determining suitability and does not constitute a warranty. It may represent the result of OMRON’s test conditions, and the users must correlate it to actual application requirements. Actual performance is subject to the OMRON Warranty and Limitations of Liability. PROGRAMMABLE PRODUCTS OMRON shall not be responsible for the user's programming of a programmable product, or any consequence thereof. COPYRIGHT AND COPY PERMISSION This catalog shall not be copied for sales or promotions without permission. This catalog is protected by copyright and is intended solely for use in conjunction with the product. Please notify us before copying or reproducing this catalog in any manner, for any other purpose. If copying or transmitting this catalog to another, please copy or transmit it in its entirety. Cat. No. J122-E1-04 OMRON Corporation 2007.7 In the interest of product improvement, specifications are subject to change without notice. Industrial Automation Company http://www.ia.omron.com/ (c)Copyright OMRON Corporation 2007 All Rights Reserved. Mouser Electronics Authorized Distributor Click to View Pricing, Inventory, Delivery & Lifecycle Information: Omron: PYF-08M
PYF14T 价格&库存

很抱歉,暂时无法提供与“PYF14T”相匹配的价格&库存,您可以联系我们找货

免费人工找货