Switching Power Supply S82K DIN-Rail Mount Power Supply with a Wide Power Range of 3 to 240 W D D D D D D D D D Universal input voltage range. All models are UL 508 listed. Class 2 approved on all models below 240 W, except dual-output types. Undervoltage indicators on all 90-W, 100-W and the 240-W “T” models have alarm and output indicators. PFC models meet EN61000-3-2 (limits for harmonic current emissions). Parallel operation capability (100 W and 240 W). Finger-safe terminal block with cover according to VDE0106/P100. Approvals: UL, CSA, VDE, and CE. 3-year warranty. uR Ordering Information J SWITCHING POWER SUPPLIES Stock Note: Shaded models are normally stocked. p Rated input voltage lt Power ratings g 100 to 240 VAC 3W 7.5 W 15 W Output p currentt Function configuration 5V 0.6 A 12 V 0.25 A Single g output t t 15 V 0.2 A S82K-00315 24 V 0.13 A S82K-00324 5V 1.5 A S82K-00705 12 V 0.6 A S82K-00712 15 V 0.5 A S82K-00715 24 V 0.3 A +12 V/–12 V 0.3 A/0.2 A +15 V/–15 V 0.2 A/0.2 A 5V 2.5 A 12 V 1.2 A 24 V 0.6 A Output p voltage g Output Switching Power Supply S82K Part number PFC No S82K-00305 S82K-00312 S82K-00724 Dual output p S82K-00727 S82K-00728 Single g output t t (This table continues on the next page.) 56 Undervoltage alarm Indicator only y S82K-01505 S82K-01512 S82K-01524 Ordering Information Table – continued from previous page Output p currentt Function configuration 5V 5.0 A 12 V 2.5 A Single g output t t 24 V 1.3 A 50 W 24 V 2.1 A 90 W 24 V 3.75 A Rated input p voltage lt Power ratings g 100 to 240 VAC 30 W 120/240 VAC selectable l t bl 100 W 120/230 VAC selectable l t bl Output p voltage g 24V 240 W 24 V Output Undervoltage alarm Indicator only y Part number PFC No S82K-03005 S82K-03012 S82K-03024 S82K-05024 Indicator and output t t 4.2 A 10 A S82K-P09024 Yes S82K-09024 No S82K-P10024 Yes S82K-10024 No S82K-24024T None 100 to 230 VAC S82K-24024 Yes S82K-P24024 J MODEL NUMBER LEGEND S82K 1 2 3 4 1. Power Factor Correction None: No P: Yes 2. Power Ratings 003: 3 W 007: 7.5 W 015: 15 W 030: 30 W 050: 50 W 090: 90 W 100: 100 W 240: 240 W 3. Output Voltage 05: +5 VDC 12: +12 VDC 15: +15 VDC 24: +24 VDC 27: Dual output +12/-12 VDC 28: Dual output +15/-15 VDC 4. Undervoltage alarm indicator/output None: Yes None:No T: Yes J ACCESSORIES (SOLD SEPARATELY) Stock Note: Shaded models are normally stocked. Noise Filter Item Applicable power supply Part number Noise filter 3- to 50-W models S82Y-JF3-N 90-W and 100-W models S82Y-JF6-N Item Length Width Part number DIN-rail ((See Dimensions section for details.)) 0.5 m (1.64 ft) 7.3 mm (0.29 in) PFP-50N 1 m (3.28 ft) 7.3 mm (0.29 in) PFP-100N 1 m (3.28 ft) 16 mm (0.63 in) PFP-100N2 DIN Rail Switching Power Supply S82K 57 Specifications J NON-PFC MODELS Item Single output Dual outputs Single output Power rating 3W 7.5 W 15 W Efficiency (typical) 60% to 80% (Varies depending on specifications.) 7.5 W 30 W 50 W 90 W 100 W 240 W Input Voltage (See Note 1.)) AC 100 to 240 V (85 to 264 V) DC 90 to 350 V (See Note 2.) Frequency 120 V (85 to 132 V)/ 240 V (170 to 264 V) Selectable 120 V (85 to 132 V)/ 230 V (170 to 253 V) Selectable Not possible 50/60 Hz (47 to 450 Hz) Current (See N Note 3 3.)) 100-V input 0.15 A max. 0.25 A max. Leakage current (S (See Note 3.) 100-V input 0.5 mA max. 200-V input 1 mA max. Inrush current (S (See Note 3.) 100-V input 15 A max. 25 A max. 200-V input 30 A max. 50 A max. 200-V input Noise filter 0.45 A max. 0.9 A max. 1.3 A max. 2.5 A max. 5.5 A max. 0.25 A max. 0.6 A max. 0.8 A max. 1.5 A max. 3.5 A max. Yes Output (See Note 4.) Voltage adjustment range r10% (V.ADJ) Not posr10% (V.ADJ); –10% to 15% for S82K-03012/-03024/-05024 sible (See Note 5.) Ripple (See Note 3.) 2% (p-p) max. Input variation influence 0.5 % max. (at 85 to 264 VAC, 100% load) Load variation influence 1.5% max. (0 to 100% load) Temperature variation influence (See Note 3.) 0.05%/qC max. Startup time 100 ms max. (up to 90% of output voltage at rated input and output) Hold time (See Note 3.) 20 ms min. +V: 1.5% max. -V: 3 % max. (0 to 100% load) 1.5% max. (0 to 100% load) 0.5 % max. (at 85 to 132 VAC/ 170 to 264 VAC input, 100% load) 0.5 % max. (at 85 to 132 VAC/170 to 253 VAC input, 100% load) 1.5% max. (10 to 100% load) 200 ms max. 300 ms max. (This table continues on the next page.) Note: 1. 2. 3. 4. 5. 58 Use with DC voltage input is beyond the conditions of approval or conformance to applicable safety standards. Use the 7.5-W single-output models under the load of 90% max. if the voltage range is between 90 and 110 VDC. Defined with a 100% load and the rated input voltage (100 or 200 VAC). The output specification is defined at the power supply output terminals. The settings for the output voltage must be within the following range: +V: r1% of the rated value –V: r5% of the rated value Switching Power Supply S82K Specifications Table – continued from previous page Item Single output Dual outputs Single output Power rating 3W 7.5 W 15 W 7.5 W 30 W 50 W 90 W 100 W 240 W Additional functions Overload protection 105% to 160% (105% to 250% for dual outputs model, 101% to 111% for 90-W model) of rated load current, automatic reset (See Note 6.) Overvoltage protection (See Note 7.) No S82K24024T model only Undervoltage alarm indicator (DC LOW indicator) Yes (color: red) S82K24024T model only Undervoltage alarm output (DC LOW output) No Yes Parallel operation Not possible Possible (2 units max.) S82K24024T model only Characteristics Ambient t temperature t Operating See the derating curve in the Engineering Data section (no condensation or icing) Storage –25qC to 65qC (-13qF to 149qF) with no condensation or icing Ambient h idit humidity Operating 25% to 85% Storage 25% to 90% Dielectric strength 3,000 VAC at 50/60 Hz for 1 min (between all inputs and outputs) 2,000 VAC at 50/60 Hz for 1 min (between all inputs and GR terminal) 1,000 VAC at 50/60 Hz for 1 min (between all outputs and GR terminal) Alarm current: 10 mA (3- to 7.5-W models) 20 mA (15- to 100-W models) 25 mA (240-W models) Insulation resistance 100 M: min. at 500 VDC (between all outputs and all inputs/GR terminal) Vibration resistance Malfunction: 10 to 55 Hz, 0.375-mm (0.15-mm for 240-W model) single amplitude for 2 hrs each in X, Y, and Z directions Shock resistance Malfunction: 300 m/s2, 3 times each in rX, rY, and rZ directions Screw tightening torque 0.74 N S m max. (See Note 8.) Output indicator Yes (green) Electromagnetic interference (See Note 3.) Conforms to FCC class B Conforms to FCC class A (This table continues on the next page.) Note: 1. 2. 3. 4. 5. 6. 7. 8. 9. 10. 11. Use with DC voltage input is beyond the conditions of approval or conformance to applicable safety standards. Use the 7.5-W single-output models under the load of 90% max. if the voltage range is between 90 and 110 VDC. Defined with a 100% load and the rated input voltage (100 or 200 VAC). The output specification is defined at the power supply output terminals. The settings for the output voltage must be within the following range: +V: r1% of the rated value –V: r5% of the rated value When using the 7.5-W single-output models within the input voltage range between 90 and 110 VDC, the protection function will operate at a current of 95% to 160% of the rated load current. When using the 90-W model under the ambient temperature over 25qC, the protection function may operate at a current of 92% to 111% of the rated load current. Circuit-breaker type. To reset, turn the input power supply OFF, then after 1 min has elapsed, turn the input power supply ON again. Do not press down on the terminal block with a force exceeding 75 N while tightening the terminals. To ensure the emission ratings, a noise filter should be used on the output lines at the closest point. (3- to 50-W models: S82Y-JF3-N, 90-W and 100-W models: S82Y-JF6-N) To ensure the Emission Enclosure rating, a ferrite ring core should be used on all cables (for S82K-P24024). To meet Class 2 requirement with 100-W model, either a fuse or circuit breaker that is UL listed or CSA certified, and rated at 4.2 A max. should be used in the output of the power supply. Only then can the power supply output be considered as meeting Class 2. Switching Power Supply S82K 59 Specifications Table – continued from previous page Item Single output Dual outputs Single output Power rating 3W 7.5 W 15 W 7.5 W 30 W 50 W 90 W 100 W 240 W Characteristics (continued) EMC (See Note 9.) 3-W to 100-W models (EMI): Emission Enclosure: Emission AC Mains: Emission Output Ports: EN50081-1 EN55022 class B (equivalent to EN55011 class B) EN55022 class B (equivalent to EN55011 class B) EN55022 class A (with a recommended optional filter) (See Note 9.) 240-W models (EMI): Emission Enclosure: Emission AC Mains: Harmonic Current: EN50081-2 EN55011 class A (See Note 10.) EN55011 class A (See Note 10.) EN61000-3-2 (only for S82K-P24024) Common to all models (EMS): Immunity ESD: EN50082-2 EN61000-4-2: 4-kV contact discharge (level 2) 8-kV air discharge (level 3) EN61000-4-4: 2-kV power-line (level 3) 2-kV output line (level 4) EN61000-4-5: between 2-kV lines (except for 240-W models) between 4-kV line and FG (except for 240-W models) Immunity Burst: Immunity Surge: Approved standards UL508 (Listing)/1950; Class 2 Power Supply, CE; CSA C22.2 No.14/No.950; EN50178 (VDE0160), EN60950 (Conforms to VDE0106/P100) Weight 150 g max. Note: 1. 2. 3. 4. 5. 6. 7. 8. 9. 10. 11. 60 UL508 (Listing)/1012; CE; CSA C22.2 No.14, CSA E.B. 1402C; EN50178 (VDE0160), EN60950 (Conforms * 100-W model must have a fuse in the output to be Class 2. (See Note 11.) to VDE106/P100) 260 g max. 380 g max. 400 g max. 600 g max. 1,800 g max. Use with DC voltage input is beyond the conditions of approval or conformance to applicable safety standards. Use the 7.5-W single-output models under the load of 90% max. if the voltage range is between 90 and 110 VDC. Defined with a 100% load and the rated input voltage (100 or 200 VAC). The output specification is defined at the power supply output terminals. The settings for the output voltage must be within the following range: +V: r1% of the rated value –V: r5% of the rated value When using the 7.5-W single-output models within the input voltage range between 90 and 110 VDC, the protection function will operate at a current of 95% to 160% of the rated load current. When using the 90-W model under the ambient temperature over 25qC, the protection function may operate at a current of 92% to 111% of the rated load current. Circuit-breaker type. To reset, turn the input power supply OFF, then after 1 min has elapsed, turn the input power supply ON again. Do not press down on the terminal block with a force exceeding 75 N while tightening the terminals. To ensure the emission ratings, a noise filter should be used on the output lines at the closest point. (3- to 50-W models: S82Y-JF3-N, 90-W and 100-W models: S82Y-JF6-N) To ensure the Emission Enclosure rating, a ferrite ring core should be used on all cables (for S82K-P24024). To meet Class 2 requirement with 100-W model, either a fuse or circuit breaker that is UL listed or CSA certified, and rated at 4.2 A max. should be used in the output of the power supply. Only then can the power supply output be considered as meeting Class 2. Switching Power Supply S82K J PFC MODELS (S82K-Pjjj24) Notes below this table apply to this page only. Item Single output Power Rating 90 W Efficiency (typical) 60% to 80% (Varies depending on specifications.) 100 W 240 W Input Voltage 120 V (85 to 132 VAC)/240 V (170 to 264 VAC) Selectable Frequency 100 to 230 V (85 to 253 VAC) 50/60 Hz (47 to 63 Hz) Current (S N (See Note t 1 1.)) 100-V input 2.5 A max. 4 A max. 200-V input 1.0 A max. 2 A max. Power factor 100-V input --- 0.95 min. 0.95 min. 200-V input 0.7 min. Leakage g current (See (S N Note t 1 1.)) 100-V input 0.5 mA max. 200-V input 1 mA max. Inrush current (S N (See Note t 1 1.)) 100-V input 25 A max. 200-V input 50 A max. Noise filter Yes Output (See Note 2.) Voltage adjustment range r10% (V.ADJ) Ripple (See Note 1.) 2% (p-p) max. Input variation influence 0.5% max. (at 85 to 132 VAC/170 to 264 VAC input, 100% load) 0.5% max. (at 85 to 253 VAC input, 100% load) Load variation influence 1.5% max. (0 to 100% load) 1.5% max. (10 to 100% load) Temperature variation 0.05%/qC max. Start up time 200 ms max. Hold time (See Note 1.) 20 ms min. 1,000 ms max. Additional function Overload protection 101% to 111% of rated load current, inverted L drop, automatic reset (See Note 3.) 105% to 160% of rated load current, inverted L drop, automatic reset Overvoltage protection No Under voltage alarm indicator Yes (color: red) No Under voltage alarm output Yes No Parallel operation Impossible Possible (2 units max.) (See Note 4.) (PFC specifications table continues on the next page.) Note: 1. Defined with a 100% load and the rated input voltage (100 or 200 VAC) 2. The output specification is defined at the power supply output terminals. 3. When the ambient temperature exceeds 25qC, the protection function may operate at a current of 92% to 111% of the rated load current. 4. Parallel operation is set with the Parallel/Single Operation Selector Switch. Switching Power Supply S82K 61 Specifications Table PFC Models (S82K-Pjjj24) – continued from previous page Item Single output Power Rating 90 W 100 W 240 W Characteristics Ambient temperature p Ambient humidity y Operating See the derating curve in the Engineering Data section (no condensation or icing) Storage –25qC to 65qC (no condensation or icing) Operating 25% to 85% Storage 25% to 90% Dielectric strength 3,000 VAC at 50/60 Hz for 1 min. (between all inputs and outputs) 2,000 VAC at 50/60 Hz for 1 min. (between all inputs and GR terminal) 1,000 VAC at 50/60 Hz for 1 min. (between all outputs and GR terminal) Alarm current: 20 mA (90- and 100-W models) 25 mA (240-W models) Insulation resistance 100 M: min. at 500 VDC (between all outputs and all inputs/GR terminal) Vibration resistance Malfunction:10 to 55 Hz, 0.375-mm single amplitude for 2 hrs each in X, Y, and Z directions Malfunction:10 to 55 Hz, 0.15-mm single amplitude for 2 hrs each in X, Y, and Z directions Shock resistance Malfunction:150 m/s2, 3 times each in rX, rY, and rZ directions Malfunction:300 m/s2, 3 times each in rX, rY, and rZ directions Screw tightening torque 0.74 N S m max. (See Note 2.) Output indicator Yes (Green) Electromagnetic interference (See Note 1.) Conforms to FCC class A EMC (See Notes 3, 4.) 90-, 100-W Models (EMI): Harmonic Current: Emission Enclosure: Emission AC Mains: Emission Output Ports: 240-W Model (EMI): Harmonic Current: Emission Enclosure: Emission AC Mains: Common to All Models (EMS): Immunity ESD: Immunity Burst: Immunity Surge: EN50081-1 EN61000-3-2 (200 VAC input only) EN55022 class B EN55022 class B EN55022 class A (with a recommended optional filter) (See Note 3.) EN50081-2 EN61000-3-2 EN55011 class A (See Note 4.) EN55011 class A EN50082-2 EN61000-4-2: 4-kV contact discharge (level 2) 8-kV air discharge (level 3) EN61000-4-4: 2-kV power-line (level 3) 2-kV output line (level 4) EN61000-4-5: between 2-kV lines (except for 240-W models) between 4-kV line and FG (except for 240-W models) Approved standards UL508 (Listing)/1950 Class 2 (UL1310)/Class 2 (CSA C22.2 No. 950) (See Note 5.) CSA C22.2 No. 14/No. 950, EN50178 (VDE160), EN60950 Conforms to VDE0106/P100 UL508 (Listing)/1012 CSA C22.2 No. 14/E.B. 1402C, EN50178 (VDE160), EN60950, Conforms to VDE0106/P100 Weight 1,000 g max. 2,200 g max. (The notes below apply to this page only.) Note: 1. Defined with a 100% load and the rated input voltage (100 or 200 VAC) 2. Do not press down on the terminal block with a force exceeding 75 N while tightening the terminals. 3. To ensure the Emission Enclosure ratings, a noise filter should be used on the output lines at the closest point. (90- and 100-W models: S82Y-JF6-N) 4. To ensure the Emission Enclosure rating, a ferrite ring core should be used on all cables. 5. To meet Class-2 requirements with the 100-W model, either a fuse or circuit breaker that is UL listed or CSA certified, and rated at 4.2 A max. should be used in the output of the power supply. Only then can the power supply output be considered as meeting Class 2. 62 Switching Power Supply S82K J REFERENCE VALUE Item Value Definition Reliability (MTBF) 135,000 hrs min. MTBF stands for Mean Time Between Failures, which is calculated according to the probability of accidental device failures, and indicates reliability of devices. Therefore, it does not necessarily represent a life of the product. Life expectancy 8 yrs. min. The life expectancy indicates average operating hours under the ambient temperature of 40qC and a load rate of 50%. Normally this is determined by the life expectancy of the built-in aluminum electrolytic capacitor. Engineering Data J DERATING CURVE 100-W Models with PFC Parallel-Unit Operation Parallel-Unit Operation Load (%) Installation A Load (%) 100-W Models without PFC Single-Unit Operation Load (%) 3-/7.5-/15-/30-/50-/100-W Models Installation B 65 Installation A 90 Installation A 65 S82K-P10024: 85-VAC input S82K-P10024: 85-VAC input Installation B S82K-03005 Installation A Installation B Ambient temperature (qC) Ambient temperature (qC) Ambient temperature (qC) Note: When using the 7.5-W single-output models within the input voltage range between 90 and 110 VDC, the load rate will become 90% or less. 240-W Model Parallel-Unit Operation Load (%) Load (%) 240-W Model Single-Unit Operation Load (%) 90-W Models Single-Unit Operation Installation A Installation A 90 S82K-P09024: 85-VAC input 70 Installation A 65 S82K-P24024: 100-VAC input (See Note.) S82K-P24024: 100-VAC input (See Note.) Installation B Ambient temperature (qC) Ambient temperature (qC) Ambient temperature (qC) Note: 100-VAC input: 85 to 132 VAC Note: 100-VAC input: 85 to 132 VAC Switching Power Supply S82K 63 Mounting Position The derating curve can be ensured for these two kinds of installations. (A) Standard (Vertical) Installation (B) Horizontal Installation Top Top Note: Horizontal installation is not permitted for 240-W models. J OVERLOAD PROTECTION The Power Supply is provided with an overload protection function that protects the load and the power supply from possible damage by overcurrent. When the output current rises above a set value (refer to the table below), the protection function is triggered, decreasing the output voltage. When the output current falls within the rated range, the overload protection function is automatically cleared. Single output 3W 7.5 W Dual outputs Single output 7.5 W Set value 105% to 160% of rated load current (See Note 1.) Operation Inverted L drop type, automatic reset 15 W 105% to 250% of rated load current 30 W 50 W 105% to 160% of rated load current Inverted L drop/intermittent operation type, automatic reset 90 W 101% to 111% of rated load current (See Notes 2 and 3.) 100 W 240 W 105% to 160% of rated load current (See Note 3.) Inverted L drop type, automatic reset Note: 1. When using the 7.5-W single-output models within the input voltage range between 90 and 110 VDC, the overload protection function will operate at currents from 95% to 160% of the rated load current. 2. When using the 90-W model at an ambient temperature exceeding 25qC, the overload protection function will operate at currents from 92% to 111% of the rated load current. 3. When using the 100-W model with PFC in parallel operation, the overload protection function will operate at currents from 3.78 to 4.2 A. 3-/7.5-/15-/90-/100-/240-W Models 30-/50-W Models Rated voltage Output voltage (V) Output voltage (V) Rated voltage Intermittent operation 0 Output current (%) 50 100 Output current (%) Note: Do not short-circuit the output terminals of the S82K or use the S82K with excessive output current for a long time, otherwise the internal circuitry of the S82K may be deteriorated or damaged. When Using Dual Output (+/–) Models The +V output detects the total output power (+V output and -V output) to trigger the short-circuit protection against overcurrent. This protection varies depending on the -V output state. The -V output independently triggers the short-circuit protection. 64 Switching Power Supply S82K J OVERVOLTAGE PROTECTION (S82K-24024T ONLY) Output voltage (V) The Power Supply is provided with an overvoltage protection function that protects the load and the Power Supply from possible damage by overvoltage. When the output voltage rises above a set value, the protection function is triggered, shutting off the output voltage. If this occurs, reset the Power Supply by turning it off for 1 minute min. and then turning it on again. Overvoltage protection operating 10% Rated output voltage –10% Variable range J INRUSH CURRENT, STARTUP TIME, HOLD TIME Input OFF Input ON AC input voltage Inrush current on input application AC input current 96.5% 90% Output voltage Startup time: 100 to 1000 ms max. depending on the model. Hold time (20 ms min.) Switching Power Supply S82K 65 Operation J UNDERVOLTAGE ALARM INDICATOR AND OUTPUT FUNCTION (ALL MODELS EXCEPT S82K-24024/P24024) If the output voltage at the output terminal drops to 75% to 90% of the rated voltage, the red indicator of the S82K (DC LOW indicator) will be lit. In the case of the 90-W, 100-W and S82K-24024T, a voltage drop alarm will be output via the relay available in the models (DC LOW output). This function detects the voltage at the output terminal of the Power Supply. To check the precise output voltage, measure the voltage at the terminal of the load. Indicator Voltage Green: DC ON Red: DC LOW Green: DC ON Operation of 90-W, 100-W, S82K-24024T’s output (DC LOW output) (See Note 2.) If the voltage at the output terminal is more than 82% of the rated voltage and operation is normal, the green indicator will be lit and the red indicator will not be lit. Red: If the voltage at the output terminal drops to below (See Note 1.) 82% of the rated voltage, the red indicator will be lit. DC LOW (See Note 3.) Green: DC ON Red: DC LOW If the voltage at the output terminal is 0 V, both the green and red indicators will not be lit. Note: 1. The more the voltage at the output terminal drops, the darker both the green and red indicators will be. 2. The relay contacts have a capacity of 0.1 A at 24 VDC. 3. The red indicator will actually first light at a voltage between 75% and 90% of the rated voltage. J BLOCK DIAGRAMS S82K-003jj (3 W) S82K-007jj (7.5 W, Single Output) Fuse (1 A) +V AC (L) Noise filter –V AC (N) Inrush current Rectifier protection circuit Rectifier Undervoltage alarm indicator Drive control circuit Overload alarm circuit Detector Photocoupler S82K-007jj (7.5 W, Dual Outputs) Fuse (1 A) –V AC (L) Noise filter AC (N) Inrush current Rectifier protection circuit Rectifier 3-terminal REG +V Undervoltage alarm indicator Drive control circuit Rectifier Overload alarm circuit Detector Photocoupler 66 Switching Power Supply S82K S82K-015jj (15 W) S82K-030jj (30 W) S82K-05024 (50 W) Fuse (3 A) +V AC (L) Noise filter –V AC (N) Inrush current Rectifier protection circuit Rectifier Undervoltage alarm indicator Drive control circuit Overload alarm circuit Detector Photocoupler S82K-09024 (90 W) S82K-10024 (100 W) Fuse (5 A) Rectifier +V AC (L) Noise filter –V AC (N) Rectifier Inrush current protection circuit 100 or 200 V Selectable terminals (See Note.) DC LOW Undervoltage alarm indicator/output Drive control circuit Overload alarm circuit Detector Photocoupler Note: Use the short bar to short-circuit terminals 7 and 8 to select 100 to 120 VAC and remove the short bar to select 200 to 240 VAC. S82K-P09024 (90 W) S82K-P10024 (100 W) Fuse (5 A) Harmonic current emission control Inrush current (200-V input only) protection circuit Rectifier +V AC (L) Noise filter –V AC (N) Rectifier 100 or 200 V Selectable terminals (See Note.) Drive control circuit Undervoltage alarm indicator Overload alarm circuit Detector Photocoupler Note: Use the short bar to short-circuit terminals 7 and 8 to select 100 to 120 VAC and remove the short bar to select 200 to 240 VAC. Switching Power Supply S82K 67 S82K-24024j (240 W) Fuse (5 A) AC (L) INPUT Noise filter AC (N) Inrush current Rectifier protection circuit 100 or 200 V Selectable terminals (See Note 2.) Rectifying and smoothing circuit Drive control circuit +V DC OUTPUT –V Detector GR DC LOW Photocoupler Overload alarm circuit Overvoltage alarm circuit Undervoltage alarm indicator/output (See Note 1.) Overvoltage protection circuitry (See Note 1.) Note: 1. The overvoltage protection circuitry and undervoltage alarm indicator/output are available in the S82K-24024T only. 2. Use the short bar to short-circuit terminals 7 and 8 to select 100 to 120 VAC and remove the short bar to select 200 to 230 VAC. S82K-P24024 (240 W) Fuse (8 A) AC (L) INPUT +V DC OUTPUT Noise filter AC (N) Inrush current protection circuit Rectifier Harmonic current Smoothing emission control Rectifying and smoothing circuit Drive control circuit Overload alarm circuit Detector Photocoupler GR 68 Switching Power Supply S82K –V Dimensions Unit: mm (inch) J S82K-003jj (3 W) S82K-007jj (7.5 W) 37.5 (1.48) 9.8 8.3 Mounting Brackets (Supplied with the Power Supply) 65 (2.56) Used when not mounting the Power Supply directly on the DIN rail. 75 (2.95) 45 Two, 4.5 dia. 35 58.1 25 35 4.6 (sliding 7 max.) 27 37.5 4 M3.5 with square washer Mounting Holes Attached Mounting Bracket M4 or 4.5-dia. hole 27 L (See Note.) Note: If more than one Power Supply is installed in a row, keep a distance of 20 mm min. (L = 20 mm min.) between each adjacent Power Supply. J S82K-015jj (15 W) 45 (1.77) 9.8 8.3 7.5 45 75 58.1 (2.95) 35 91 (3.58) 4.6 (sliding 7 max.) 5 M3.5 with square washer Mounting Holes Two, M4 or 4.5-dia. mounting holes 60 (2.36) L (See Note.) 35 Note: If more than one Power Supply is installed in a row, keep a distance of 20 mm min. (L = 20 mm min.) between each adjacent Power Supply. Switching Power Supply S82K 69 J S82K-030jj (30 W) S82K-05024 (50 W) 90 (3.54) 80 Four, 4.5 dia. 58.1 60 75 (2.95) M3.5 with square washer 4 (sliding 7 max.) 7.5 45 35.2 91 (3.58) 5 Mounting Holes Four, M4 or 4.5-dia. mounting holes 60 (2.36) L (See Note.) 70 Switching Power Supply 80 (3.15) S82K Note: If more than one Power Supply is installed in a row, keep a distance of 20 mm min. (L = 20 mm min.) between each adjacent Power Supply. Unit: mm (inch) J S82K-j09024 (90 W) S82K-j10024 (100 W) 145 (5.71) Four, 4.5 dia. 135 9.8 8.3 7.5 75 58.1 (2.95) 60 45 35.2 91 (3.58) 4 (sliding 7 max.) M3.5 with square washer 5 M3.5 terminal screw Short bar Mounting Holes Four, M4 or 4.5-dia. mounting holes 60 (2.36) Note: If more than one Power Supply is installed in a row, keep a distance of 20 mm min. (L = 20 mm min.) between each adjacent Power Supply. L (See Note.) 135 (5.31) Switching Power Supply S82K 71 J S82K-j24024j (240 W) 280 (11.02) 270 9.8 8.3 Four, 4.5 dia. 7.8 27.5 112.8 (4.44) 100 (3.94) 130 (5.12) 4 (sliding 8 max.) M3.5 with square washer M3.5 terminal screw Short bar 115 (4.53) 35 138 (5.43) 4.2 Mounting Holes L (See Note.) 270 (10.63) 115 (4.53) Four, M4 or 4.5-dia. mounting holes 72 Switching Power Supply S82K Note: If more than one Power Supply is installed in a row, keep a distance of 20 mm min. (L = 20 mm min.) between each adjacent Power Supply. Unit: mm (inch) J ACCESSORIES Noise Filter (Order Separately) S82Y-JF3-N for 3- to 50-W models S82Y-JF6-N for 90- and 100-W Models Two, 4.8 dia. (Mounting holes) A B 16 max. 16 max. D 4 39 47 Nameplate 4 6.5 Six, M4 6.5 C Model A B C D S82Y-JF3-N 107 (4.21) 75 (2.95) 90 (3.54) 26 (1.02) S82Y-JF6-N 117 (4.60) 85 (3.35) 100 (3.93) 30 (1.18) DIN Rail Mounting Track (Order Separately) PFP-100N/PFP-50N PFP-100N2 12, 25 x 4.5 oblong 7.3 4.5 35 15 25 25 10 25 1,000 (500) (See Note.) 25 10 15 (5) (See Note.) 16 4.5 35 27 1 15 25 25 10 25 1,000 27 25 15 10 24 29.2 1 1.5 Note: The values shown in parentheses are for the PFP-50N. Switching Power Supply S82K 73 Installation J S82K-003jj/ S82K-007jj (Single Output) J S82K-007jj (Dual outputs) 1 1 J S82K-015jj 1 1 5 5 7 5 7 7 6 6 2 3 2 J S82K-030jj/ S82K-05024 3 J S82K-j09024/ S82K-j10024 8 1 5 5 7 7 6 6 2 2 3 3 1 2 3 4 Bottom view (Only for S82K-P10024) 9 74 Switching Power Supply S82K J S82K-j24024j 6 7 5 8 1 2 Bottom view 3 4 1. DC Output Terminals: Connect the load lines to these terminals. 2. Input Terminals: Connect the input lines to these terminals. 3. Ground Terminal (GR): Connect a ground line to this terminal. 4. Input Voltage Selector Terminals: Selects a 100-V or 200-V input voltage. 5. Output Indicator (DC ON): Lights while a Direct Current (DC) output is ON. 6. Output Voltage Adjuster(V.ADJ): It is possible to increase or decrease the output voltage. 9 7. Undervoltage Alarm Indicator (DC LOW): Other than S82K-24024 and S82K-P24024 models. 8. Undervoltage Alarm Output (DC LOW): S82K-j09024/-j10024/-24024T models only. 9. Parallel/Single Operation Selector: Set to “PARALLEL” or “P” for parallel operation. Switching Power Supply S82K 75 Precautions ! Caution Be sure to connect the grounding line. Not doing so may result in electric shock. J REMOVAL To remove the Power Supply, pull down portion (C) with a flat-blade screwdriver and pull out the Power Supply. ! WARNING Do not attempt to disassemble the Power Supply or touch its internal parts while power is being supplied. Doing so may result in electric shock. Do not touch the terminals of the Power Supply within one minute after power has been turned OFF. Doing so may result in electric shock due to a residual voltage. 30 mm min. Do not touch the Power Supply Unit while power is being supplied or immediately after power has been turned OFF. Doing so may result in a skin burn due to high temperature of the Power Supply. (C) Track stopper When tightening the terminals, do not tighten the terminal block to a torque greater than 75 N. J MOUNTING To improve and maintain the reliability of the Power Supply over a long period of time, consider the heat dissipation. J SELECTION OF 100 TO 120 VAC OR 200 TO 240 VAC INPUT VOLTAGE (S82K-j09024/-j10024/-24024/-24024T) The Power Supply is designed to dissipate heat by means of natural air-flow. Mount the Power Supply so that air flow takes place around the Power Supply. Select a 120 V or 240 V input by shorting or opening the Input Voltage Selector Terminals, as shown in the following diagram. The default setting is 240 V. 100-V to 120-V Input Note: Use the short bar to short-circuit terminals 7 and 8. Air When mounting two or more Power Supplies side-by-side, allow at least 20 mm (0.79 in) spacing between them, as shown in the following illustration. 6 7 8 200-V to 240-V Input Forced-air cooling is recommended. Note: Remove the short bar. 20 mm min. 6 To mount the Power Supply on a DIN rail, hook portion (A) of the Power Supply to the rail and press the Power Supply toward direction (B). (A) (B) 76 Switching Power Supply S82K 7 8 J GENERATING OUTPUT VOLTAGE (r) J PARALLEL OPERATION An output of r can be generated by using two Power Supplies (as shown below) because the Power Supply produces a floating output. S82K 100-W/240-W models can be operated in parallel. Perform parallel operation with power supplies satisfying the same specifications. +V INPUT 100-W and 240-W Models –V +V INPUT Load –V +V INPUT –V +V When connecting the Power Supplies in series with an operation amplifier, connect diodes to the output terminals as shown by the dotted lines in the figure. No diodes are required with S82K 90-/100-/240-W models. J WIRING To prevent incorrect wiring of the input/output terminals, pay attention to their polarities. J BATTERY CHARGING With S82K-j09024/-j10024/-24024T models, a reduction in lifetime due to over discharge of the battery can be prevented using the DC LOW output. (Discharge can be interrupted at 0.75 to 0.9 u 24 V.) INPUT –V Note: When operating the S82K-P10024 or 240-W model in parallel operation, set the switch to “PARALLEL.” Refer to the derating curve for the rated current under this operation. 3-, 7.5-, 15-, 30-, 50- and 90-W Models +V INPUT Load –V J SERIES OPERATION S82K 90-W/100-W/240-W models can be operated in series. It must be noted that the + output of the 7.5-W dual output model cannot be connected in series to its – output. +V INPUT –V 90-W/100-W/240-W Models +V J PARALLEL OPERATION PRECAUTIONS –V x INPUT +V INPUT x –V x 3-, 7.5-, 15-, 30-, 50-W Models +V INPUT –V x The length and thickness of each wire connected to the load must be the same so there is no difference in voltage drop value between the load and the output terminals of each Power Supply. Adjust the output voltage of each Power Supply so there will be no difference in output voltage between each Power Supply. If the S82K-P10024 or 240-W Power Supply is used in single operation under the parallel operation setting, the overcurrent protection will be actuated at an output of 90% to 95% (in current) and will not allow a 100% output. If the S82K-P10024 or 240-W Power Supplies are used in parallel operation under the single operation setting, one of them will operate at 110% output, causing severe heat derating and shortening the service life. +V INPUT –V Switching Power Supply S82K 77 Minimum Output Current Operating and Storage Environments The minimum output current of the S82K-00727 and S82K-00728 is restricted by the output voltage and control method. To avoid deterioration of the operating characteristics or malfunction, do NOT use or store the Unit in locations subject to the following conditions: Note: All the outputs of the S82K-00727 and S82K-00728 are controlled by the +V output. If the +V output current falls to 10% or less of the rated output, the –V output voltage may drop. x x x x x x x x x 78 Switching Power Supply S82K Direct sunlight. Ambient operating temperatures outside the range indicated by the derating curve. Ambient operating humidity outside the range of 25% to 85%. Condensation as the result of severe changes in temperature. Ambient storage temperatures outside the range of –25qC to 65qC. Corrosive or flammable gases. Dust (especially iron dust) or salts. Shock or vibration. Exposure to water, oil, or chemicals. $//',0(16,2166+2:1$5(,10,//,0(7(567RFRQYHUWPLOOLPHWHUVLQWRLQFKHVGLYLGHE\ 20521(/(&7521,&6//& 2QH&RPPHUFH'ULYH 6FKDXPEXUJ,/  )RU86WHFKQLFDOVXSSRUWRURWKHULQTXLULHV 20521&$1$'$,1& 2052121/,1(  *OREDOKWWSZZZRPURQFRP 86$KWWSZZZRPURQFRPRHL &DQDGDKWWSZZZRPURQFD 0LOQHU$YHQXH 7RURQWR2QWDULR0%9  Cat No. GC PS6 2/03 Specifications subject to change without notice Switching Power Supply Printed in USA S82K 79
S82K-03024
物料型号:S82K系列,包括多种功率等级和输出电压的开关电源。

器件简介:S82K系列是DIN轨道安装式开关电源,具有3W至240W的宽电源范围,适用于多种输入电压范围,所有型号均已通过UL 508认证。

引脚分配:文档中未明确列出引脚分配,但提到了输入、输出和接地端子。

参数特性: - 效率:典型值为60%至80%,具体取决于规格。 - 输入电压:交流100至240V或120/240V可切换。 - 输出电流:根据型号不同而变化。 - 附加功能:包括过载保护、欠压报警指示/输出、并联操作能力等。

功能详解: - PFC型号符合EN61000-3-2标准,限制谐波电流发射。 - 90W、100W和240W型号具备欠压指示和输出指示。 - 100W和240W型号具备并联操作能力。

应用信息:适用于需要宽输入电压范围和高效率的开关电源应用。

封装信息:提供了详细的安装尺寸和配件信息,包括噪音过滤器和DIN轨道安装部件。
S82K-03024 价格&库存

很抱歉,暂时无法提供与“S82K-03024”相匹配的价格&库存,您可以联系我们找货

免费人工找货