0
登录后你可以
  • 下载海量资料
  • 学习在线课程
  • 观看技术视频
  • 写文章/发帖/加入社区
会员中心
创作中心
发布
  • 发文章

  • 发资料

  • 发帖

  • 提问

  • 发视频

创作活动
S8VS-09024B

S8VS-09024B

  • 厂商:

    OMRON(欧姆龙)

  • 封装:

    -

  • 描述:

    AC/DCCONVERTER24V90W

  • 数据手册
  • 价格&库存
S8VS-09024B 数据手册
Switch Mode Power Supply Power supplies S8VS 15/30-W Models Compact, Thin Power Supplies That Mount Just About Anywhere to Contribute to Control Panel Downsizing • Compact, thin size: 22.5 × 85 × 96.5 mm (W × H × D). • Three mounting directions (standard, horizontal, facing horizontal). • Mounting directly onto the panel is possible. • Safety standards: UL508/60950-1/1604, CSA C22.2 No. 14/60950-1/213, EN50178 (= VDE0160), EN60950-1 (= VDE0805). 60/90/120/180/240-W Models New Models with Total Run Time Monitor in Addition to Models with Maintenance Forecast Monitor • Compact size: 40 × 95 mm (W × H) (60-W Models). • Status displayed on 3-digit, 7-segment display. • Safety standards: UL508/60950, CSA C22.2 No. 14/60950, EN50178 (= VDE0160), EN60950 (= VDE0805). Features Common to All Models • Mount to DIN-rail. • Lead-free solder. Switch Mode Power Supply S8VS B-5 Model Number Structure ■ Model Number Legend S8VS- @@@@@@@ 1 2 3 3. Configuration 15-W, 30-W Models None: Standard 1. Power Ratings 015: 15 W 030: 30 W 060: 60 W 090: 90 W 120: 120 W 180: 180 W 240: 240 W 60-W Models None: Standard A: With maintenance forecast monitor B: With total run time monitor 2. Output voltage 05: 5 V 12: 12 V 24: 24 V 90-W, 120-W, 180-W, 240-W Models None: Standard A: With maintenance forecast monitor and undervoltage alarm (transistor (sinking)) B: With total run time monitor and undervoltage alarm (transistor (sinking)) AP: With maintenance forecast monitor and undervoltage alarm (transistor (sourcing)) BP: With total run time monitor and undervoltage alarm (transistor (sourcing)) Ordering Information Power ratings 15 W 30 W 60 W Input Voltage 100 to 240 VAC Output voltage Output current 5V 2.0 A 12 V 1.2 A 24 V 0.65 A 5V 4.0 A 12 V 2.5 A 24 V 1.3 A 24 V 2.5 A Alarm output --- Model number S8VS-01505 (See note 1.) S8VS-01512 S8VS-01524 --- S8VS-03005 (See note 2.) S8VS-03012 S8VS-03024 --- S8VS-06024 S8VS-06024A S8VS-06024B 90 W 3.75 A 120 W 5A 180 W 7.5 A 240 W 10 A Note: 1. The output capacity of the S8VS-01505 is 10 W. 2. The output capacity of the S8VS-03005 is 20 W. B-6 Switch Mode Power Supply S8VS --- S8VS-09024 Sinking S8VS-09024A Sourcing S8VS-09024AP Sinking S8VS-09024B Sourcing S8VS-09024BP --- S8VS-12024 Sinking S8VS-12024A Sourcing S8VS-12024AP Sinking S8VS-12024B Sourcing S8VS-12024BP --- S8VS-18024 Sinking S8VS-18024A Sourcing S8VS-18024AP Sinking S8VS-18024B Sourcing S8VS-18024BP --- S8VS-24024 Sinking S8VS-24024A Sourcing S8VS-24024AP Sinking S8VS-24024B Sourcing S8VS-24024BP Specifications Power ratings Type Item Efficiency (typical) Input Voltage Frequency Current 5-V models 12-V models 24-V models 100 V input 200 V input 230 V input Power factor Harmonic current emissions Leakage current 100 V input 200 V input 230 V input Inrush current 100 V input (See note 1.) 200 V input 230 V input Voltage adjustment range (See note 2.) Ripple Output 15 W Standard 72% min. (76% typ.) 74% min. (79% typ.) 77% min. (81% typ.) 100 to 240 VAC (85 to 264 VAC) 50/60 Hz (47 to 450 Hz) 0.45 A max. 0.25 A max. 5 V: (0.14 A typ.), 12 V/24 V (0.19 A typ.) --Conforms to EN61000-3-2 0.5 mA max. 1.0 mA max. 5 V/12 V/24 V: (0.30 mA typ.) 25 A max. (20 A typ.) (for a cold start at 25°C) 50 A max. (40 A typ.) (for a cold start at 25°C) 5 V/12 V/24 V: (29 A typ.) (See note 6.) −10% to 15% (with V.ADJ) (guaranteed) Power supplies ■ Ratings/Characteristics 30 W Standard 70% min. (76% typ.) 76% min. (83% typ.) 80% min. (85% typ.) 0.9 A max. 0.6 A max. 5 V: (0.27 A typ.), 12 V/24 V (0.37 A typ.) 5 V/12 V/24 V:(0.32 mA typ.) 5 V/12 V/24 V: (40 A typ.) (See note 6.) 2.0% (p-p) max. (at rated input/output voltage) 5 V: (0.70%(p-p) typ.), 12 V:(0.48%(p-p) typ.), 24 V:(0.25%(p-p) 5 V: (0.70%(p-p) typ.), 12 V:(0.52%(p-p) typ.), 24 V:(0.19%(p-p) typ.) typ.) f=100MHz measuring 5 V: (0.86%(p-p) typ.), 12 V:(0.56%(p-p) typ.), 24 V:(0.32%(p-p) 5 V: (0.80%(p-p) typ.), 12 V:(0.58%(p-p) typ.), 24 V:(0.21%(p-p) typ.) typ.) Input variation influence 0.5% max. (at 85 to 264 VAC input, 100% load) Load variation influence (rated input voltage) 2.0% max. (5 V), 1.5% max. (12 V, 24 V), (with rated input, 0 to 100% load) Temperature variation influence 0.05%/°C max. Start up time (See note 1 and 7.) 100 ms max. (at rated input/output voltage) 1,000 ms max. (at rated input/output voltage) 5 V: (6 ms typ.), 12 V: (12 ms typ.), 24 V: (18 ms typ.) 5 V/12 V/24 V: (240 ms typ.) Hold time (See note 1.) 20 ms min. (at rated input/output voltage) at 100% load 5 V: (328 ms typ.), 12V: (251 ms typ.), 24 V: (243 ms typ.) 5 V: (299 ms typ.), 12 V: (217 ms typ.), 24 V: (210 ms typ.) Overload protection (See note 1.) 105% to 160% of rated load current, voltage drop, automatic re- 105% to 160% of rated load current, voltage drop, intermittent set operation, automatic reset Overvoltage protection (See note 1.) Yes (a zener diode clamp) (See note 3.) Yes (See note 4.) Output voltage indication No Output current indication No Peak-hold current indication No Maintenance forecast monitor indication No Maintenance forecast monitor output No Total run time monitor indication No Total run time monitor output No Undervoltage alarm indication Yes (color: red) Undervoltage alarm output No Parallel operation No Series operation Models with 24-V output: Possible for up to 2 Power Supplies (with external diode) Models with 5- or 12-V output: Not possible Operating ambient temperature Refer to the derating curve in Engineering Data. (with no icing or condensation) Storage temperature −25 to 65°C Operating ambient humidity 25% to 85% (Storage humidity: 25% to 90%) Dielectric strength 3.0 kVAC for 1 min. (between all inputs and outputs; detection current: 20 mA) 2.0 kVAC for 1 min. (between all inputs and PE terminals; detection current: 20 mA) 1.0 kVAC for 1 min. (between all outputs and PE terminals; detection current: 20 mA) Insulation resistance 100 MΩ min. (between all outputs and all inputs/ PE terminals) at 500 VDC Vibration resistance 10 to 55 Hz, 0.375-mm single amplitude for 2 h each in X, Y, and Z directions 10 to 150 Hz, 0.35-mm single amplitude (5 G max.) for 80 min. each in X, Y, and Z directions Shock resistance 150 m/s2, 3 times each in ±X, ±Y, and ±Z directions f=20MHz measuring Additional functions Other Output indicator EMI Conducted Emissions Radiated Emissions Yes (color: green) Conforms to EN61204-3 EN55011 Class B and based on FCC Class A Conforms to EN61204-3 EN55011 Class B EMS Approved standards Note: 1. 2. 3. 4. 5. 6. 7. Conforms to EN61204-3 high severity levels UL: UL508 (Listing, Class 2: Per UL1310), UL60950-1, UL1604 (Class I/Division2) cUL: CSA C22.2 No.14 (Class 2), No.60950-1, No.213 (Class I/Division2) EN/VDE: EN50178 (=VDE0160), EN60950-1 (=VDE0805) SELV (EN60950/EN50178/UL60950-1) According to VDE0106/P100, IP20 Weight 160 g max. 180 g max. Refer to the Engineering Data section on page B-21 for details. If the V.ADJ adjuster is turned, the voltage will increase by more than +15% of the voltage adjustment range. When adjusting the output voltage, confirm the actual output voltage from the Power Supply and be sure that the load is not damaged. The overvoltage protection of the S8VS-015@@ uses a zener diode clamp. If the internal feedback circuit is destroyed by any chance, the load may be destroyed by the clamped output voltage (approx. 140% to 190% of the rated output voltage). To reset the protection, turn OFF the power supply for three minutes or longer and then turn the power supply back ON. The typical values indicate the values for an input condition of 230 VAC. All items are measured at a frequency of 50 Hz. The inrush current circuits do not differ for voltage specifications. Therefore, the typical values are the data values for 24-V models. The circuit forms are different, so the start up time is shorter only when using a 15-W power rating. Switch Mode Power Supply S8VS B-7 Specifications ■ Ratings/Characteristics Power ratings Type Standard Item Efficiency (typical) Input Voltage Frequency Current Output Additional functions 60 W Maintenance forecast monitor Total run time monitor Standard 90 W Maintenance forecast monitor Total run time monitor 78% min. (86% typ.) 80% min. (87% typ.) 100 to 240 VAC (85 to 264 VAC) 50/60 Hz (47 to 450 Hz) 100 V input 1.7 A max. 2.3 A max. 200 V input 1.0 A max. 1.4 A max. 230 V input (0.7 A typ.) (0.9 A typ.) Power factor --Harmonic current emissions Conforms to EN61000-3-2 Leakage current 100 V input 0.5 mA max. 200 V input 1.0 mA max. 230 V input (0.40 mA typ.) (0.35 mA typ.) Inrush current 100 V input 25 A max. (for a cold start at 25°C) (See note 1.) 200 V input 50 A max. (for a cold start at 25°C) 230 V input (47 A typ.) (38 A typ.) Voltage adjustment range (See note 2.) −10% to 15% (with V.ADJ) (guaranteed) Ripple 2.0% (p-p) max. (at rated input/output voltage) f=20MHz measuring (0.29% (p-p) typ.) (0.38% (p-p) typ.) f=100MHz measuring (0.32% (p-p) typ.) (0.42% (p-p) typ.) Input variation influence 0.5% max. (at 85 to 264 VAC input, 100% load) Load variation influence (rated input voltage) 1.5% max. (with rated input, 0 to 100% load) Temperature variation influence 0.05%/°C max. Start up time (See note 1.) 1,000 ms max. (at rated input/output voltage) (270 ms typ.) (260 ms typ.) Hold time (See note 1.) 20 ms min. (at rated input/output voltage) at 100% load (220 ms typ.) (190 ms typ.) Overload protection (See note 1.) 105% to 160% of rated load current, voltage drop, intermittent, automatic reset Overvoltage protection (See notes 1 and 3.) Yes Output voltage indication (See note 4.) No Yes (selectable) (See note 5.) No Yes (selectable) (See note 5.) Output current indication (See note 4.) No Yes (selectable) (See note 6.) No Yes (selectable) (See note 6.) Peak-hold current indication (See note 4.) No Yes (selectable) (See note 7.) No Yes (selectable) (See note 7.) Maintenance forecast monitor indication (See note 4.) No Yes (selectable) No No Yes (selectable) No Yes (open collector out- No Maintenance forecast monitor output No put), 30 VDC max., 50 mA max. (See note 8.) Total run time monitor indication (See note 4.) Total run time monitor output No No Undervoltage alarm indication (See note 4.) No Undervoltage alarm output terminals No Other Parallel operation Series operation Operating ambient temperature Storage temperature Operating ambient humidity Dielectric strength Insulation resistance Vibration resistance Yes (selectable) Yes (open collector output), 30 VDC max., 50 mA max. (See note 8.) Yes (selectable) No Yes (selectable) Yes (open collector output) 30 VDC max., 50 mA max. (See note 8.) 150 m/s2, 3 times each in ±X, ±Y, and ±Z directions Yes (color: green) Conducted Conforms to EN61204-3 EN55011 Class A and based on FCC Class A Emissions Conforms to EN61204-3 EN55011 Class B (See note 9.) Radiated Conforms to EN61204-3 EN55011 Class A Emissions Conforms to EN61204-3 EN55011 Class B (See note 9.) EMS Conforms to EN61204-3 high severity levels Approved standards UL: UL508 (Listing, Class 2: Per UL1310), UL60950 UL: UL508 (Listing), UL60950 cUL: CSA C22.2 No.14 (Class 2), No.60950 cUL: CSA C22.2 No.14, No.60950 EN/VDE: EN50178 (=VDE0160), EN60950 (=VDE0805) EN/VDE: EN50178 (=VDE0160), EN60950 (=VDE0805) SELV (EN60950/EN50178/UL60950-1) SELV (EN60950/EN50178/UL60950-1) According to VDE0106/P100, IP20 According to VDE0106/P100, IP20 Weight 330 g max. 490 g max. 1. Refer to the Engineering Data section on page B-21 for details. 2. If the V.ADJ adjuster is turned, the voltage will increase by more than +15% of the voltage adjustment range (by more than +10% for 240-W models). When adjusting the output voltage, confirm the actual output voltage from the Power Supply and be sure that the load is not damaged. 3. To reset the protection, turn OFF the power supply for three minutes or longer and then turn the power supply back ON. 4. Displayed on 7-segment LED. (character height: 8 mm) 5. Resolution of output voltage indication: 0.1 V, Precision of output voltage indication: ±2% (percentage of output voltage value, ±1 digit) 6. Resolution of output current indication: 0.1 A; Precision of output current indication: ±5% F.S. ±1 digit max. (specified by rated output voltage) 7. Resolution of peak-hold current indication: 0.1 A; Precision of peak-hold current indication: ±5% F.S. ±1 digit max. (specified by rated output voltage); Signal width required for peak-hold current: 20 ms 8. A Type and B Type: Sinking, AP Type and P Type: Sourcing 9. To ensure the emission rating, a ferrite ring core should be used in all cabling (TDK HF60T, HF70RH or equivalent model). 10. The typical values indicate the values for an input condition of 230 VAC. All items are measured at a frequency of 50 Hz. Output indicator EMI B-8 No No Yes for up to 2 Power Supplies (with external diode) Refer to the derating curve in Engineering Data. (with no icing or condensation) −25 to 65°C 25% to 85% (Storage humidity: 25% to 90%) 3.0 kVAC for 1 min. (between all inputs and outputs/ alarm outputs; detection current: 20 mA) 2.0 kVAC for 1 min. (between all inputs and PE terminals; detection current: 20 mA) 1.0 kVAC for 1 min. (between all outputs/ alarm outputs and PE terminals; detection current: 20 mA) 500 VAC for 1 min. (between all outputs and alarm outputs; detection current: 20 mA) 100 MΩ min. (between all outputs/ alarm outputs and all inputs/ PE terminals) at 500 VDC 10 to 55 Hz, 0.375-mm single amplitude for 2 h each in X, Y, and Z directions 10 to 150Hz, 0.35-mm single amplitude (5 G max.) for 80 min each in-X, Y, and Z directions Shock resistance Note: Yes (selectable) Switch Mode Power Supply S8VS 120 W 180 W 240 W Maintenanc Total run Standard Maintenanc Total run Standard Maintenanc Total run e forecast time e forecast time e forecast time Item monitor monitor monitor monitor monitor monitor Efficiency (typical) 80% min. (87% typ.) 80% min. (88% typ.) 80% min. (86% typ.) Input Voltage 100 to 240 VAC (85 to 264 VAC) Frequency 50/60 Hz (47 to 63 Hz) Current 100 V input 1.9 A max. 2.9 A max. 3.8 A max. 200 V input 1.1 A max. 1.6 A max. 2.0 A max. 230 V input (0.6 A typ.) (0.9 A typ.) (1.2 A typ.) Power factor 0.95 min. Harmonic current emissions Conforms to EN61000-3-2 Leakage current 100 V input 0.5 mA max. 200 V input 1.0 mA max. 230 V input (0.43 mA typ.) (0.45 mA typ.) (0.45 mA typ.) Inrush current 100 V input 25 A max. (for a cold start at 25°C) (See note 1.) 200 V input 50 A max. (for a cold start at 25°C) 230 V input (41 mA typ.) (34 mA typ.) (39 mA typ.) Output Voltage adjustment range (See note 2.) −10% to 15% (with V.ADJ) (guaranteed) ±10% (with V.ADJ) (guaranteed) Ripple 2.0% (p-p) max. (at rated input/output voltage) f=20MHz measuring (0.66%(p-p) typ.) (0.45%(p-p) typ.) (0.13%(p-p) typ.) f=100MHz measuring (0.67%(p-p) typ.) (0.52%(p-p) typ.) (0.21%(p-p) typ.) Input variation influence 0.5% max. (at 85 to 264 VAC input, 100% load) Load variation influence (rated input voltage) 1.5% max. (with rated input, 0 to 100% load) Temperature variation influence 0.05%/°C max. Start up time (See note 1.) 1,000 ms max. (at rated input/output voltage) (380 ms typ.) (530 ms typ.) (780 ms typ.) Hold time (See note 1.) 20 ms min. (at rated input/output voltage) at 100% load (60 ms typ.) (60 ms typ.) (30 ms typ.) Addition- Overload protection (See note 1.) 105% to 160% of rated load current, voltage drop, intermittent, automatic reset 105% to 160% of rated load al funccurrent, voltage drop, autotions matic reset Overvoltage protection (See notes 1 and 3.) Yes Output voltage indication (See note 4.) No Yes (selectable) No Yes (selectable) No Yes (selectable) (See note 5.) (See note 5.) (See note 5.) Output current indication (See note 4.) No Yes (selectable) No Yes (selectable) No Yes (selectable) (See note 6.) (See note 6.) (See note 6.) Peak-hold current indication (See note 4.) No Yes (selectable) No Yes (selectable) (See note No Yes (selectable) (See note 7.) 7.) (See note 7.) Maintenance forecast monitor indication No Yes No No Yes No No Yes No (See note 4.) (selectable) (selectable) (selectable) Maintenance forecast monitor output No Yes No No Yes No No Yes No (open collec(open collec(open collector output), tor output), tor output), 30 VDC 30 VDC 30 VDC max., 50 mA max., 50 mA max., 50 mA max. max. max. (See note 8.) (See note 8.) (See note 8.) Total run time monitor indication No Yes No Yes No Yes (See note 4.) (selectable) (selectable) (selectable) Total run time monitor output No Yes (open No Yes (open No Yes (open collector outcollector outcollector output), 30 VDC put), 30 VDC put), 30 VDC max., 50 mA max., 50 mA max., 50 mA max. max. max. (See note 8.) (See note 8.) (See note 8.) Undervoltage alarm indication (See note 4.) No Yes (selectable) No Yes (selectable) No Yes (selectable) Undervoltage alarm output terminals No Yes (open collector output), No Yes (open collector output), No Yes (open collector output), 30 VDC max., 50 mA max. 30 VDC max., 50 mA max. 30 VDC max., 50 mA max. (See note 8.) (See note 8.) (See note 8.) Parallel operation No Series operation Yes for up to 2 Power Supplies (with external diode) Other Operating ambient temperature Refer to the derating curve in Engineering Data. (with no icing or condensation) Storage temperature −25 to 65°C Operating ambient humidity 25% to 85% (Storage humidity: 25% to 90%) Dielectric strength 3.0 kVAC for 1 min. (between all inputs and outputs/ alarm outputs; detection current: 20 mA) 2.0 kVAC for 1 min. (between all inputs and PE terminals; detection current: 20 mA) 1.0 kVAC for 1 min. (between all outputs/ alarm outputs and PE terminals; detection current: 20 mA) 500 VAC for 1 min. (between all outputs and alarm outputs; detection current: 20 mA) Insulation resistance 100 MΩ min. (between all outputs/ alarm outputs and all inputs/ PE terminals) at 500 VDC Vibration resistance 10 to 55 Hz, 0.375-mm single amplitude for 2 h each in X, Y, and Z directions 10 to 150Hz, 0.35-mm single amplitude (5 G max.) for 80 min each in-X, Y, and Z directions Shock resistance 150 m/s2, 3 times each in ±X, ±Y, and ±Z directions Output indicator EMI EMS Approved standards Weight Conducted Emissions Radiated Emissions Standard Yes (color: green) Conforms to EN61204-3 EN55011 Class A and based on FCC Class A Conforms to EN61204-3 EN55011 Class B (See note 9.) Conforms to EN61204-3 EN55011 Class A Conforms to EN61204-3 EN55011 Class B (See note 9.) Conforms to EN61204-3 high severity levels UL: UL508 (Listing), UL60950 cUL: CSA C22.2 No.14, No.60950 EN/VDE: EN50178 (=VDE0160), EN60950 (=VDE0805) SELV (EN60950/UL50178/UL60950-1) According to VDE0106/P100, IP20 550 g max. 850 g max. 1,150 g max. Switch Mode Power Supply S8VS B-9 Power supplies Power ratings Type Mouser Electronics Authorized Distributor Click to View Pricing, Inventory, Delivery & Lifecycle Information: Omron: S8VS-24024A S8VS-18024A S8VS-01505 S8VS-03005 S8VS-03012 S8VS-01524 S8VS-09024AP S8VS12024A S8VS-18024AP S8VS-48024B-F S8VS-18024BP S8VS-48024 S8VS-48024A S8VS-06024-F S8VS-09024 S8VS-12024B S8VS-09024B S8VS-06024A S8VS-09024A S8VS-18024 S8VS-03024 S8VS-06024 S8VS-01512 S8VS-18024B S8VS-48024B
S8VS-09024B 价格&库存

很抱歉,暂时无法提供与“S8VS-09024B”相匹配的价格&库存,您可以联系我们找货

免费人工找货