SHL-Q55-01

SHL-Q55-01

  • 厂商:

    OMRON(欧姆龙)

  • 封装:

    -

  • 描述:

    检测开关 单刀双掷 DC30V AC125V

  • 数据手册
  • 价格&库存
SHL-Q55-01 数据手册
Enclosed Switch SHL CSM_SHL_DS_E_4_5 Compact, General-purpose Horizontal Switches. Models for Microloads Added to Series • Approved by EN, UL, CSA, and CCC (Chinese standard). (Ask your OMRON representative for information on approved models.) • Incorporates a switch with a durable coil spring in a tough, highprecision case. • Compact and uses a single basic switch for applications where strength is required. • Models for microloads and models with operation indicators added to series. • Terminal protective cover can be switched to wire cable from either the left or right. • Sealing characteristics that meet IEC IP67 degree of protection. For the most recent information on models that have been certified for safety standards, refer to your OMRON website. Be sure to read Safety Precautions on page 7 and Safety Precautions for All Limit Switches. Ordering Information Switches Type Actuator Plunger Standard Model Micro load Model SHL-D55 SHL-D55-01 SHL-Q55 SHL-Q55-01 SHL-Q2255 SHL-Q2255-01 SHL-Q2155 SHL-Q2155-01 Short hinge lever SHL-W55 SHL-W55-01 Hinge lever SHL-W155 SHL-W155-01 Panel mount plunger Panel mount roller plunger Panel mount crossroller plunger Type Actuator Short hinge roller lever Hinge roller lever One-way action short hinge roller lever One-way action hinge roller lever Standard Model Micro load Model SHL-W255 SHL-W255-01 SHL-W2155 SHL-W2155-01 SHL-W355 SHL-W355-01 SHL-W3155 SHL-W3155-01 Note: Models are also available with molded terminals and with molded terminals and operation indicators. Refer to page 6. 1 SHL Molded Terminal Models with Wire Cable Without Operation Indicator Location of lead outle Right-hand Left-hand Underside Type Actuator Plunger Panel mount plunger Panel mount roller plunger Panel mount crossroller plunger Short hinge lever Hinge lever Short hinge roller lever Hinge roller lever One-way action short hinge roller lever Plunger Panel mount roller plunger Panel mount crossroller plunger Short hinge lever Hinge lever Short hinge roller lever Hinge roller lever Plunger Panel mount plunger Panel mount roller plunger Panel mount crossroller plunger Short hinge lever Hinge lever Short hinge roller lever Hinge roller lever One-way action short hinge roller lever Standard Model Micro load Model SHL-D55-MR VCTF 3M SHL-D55-01MR VCTF 3M SHL-Q55-MR VCTF 3M SHL-Q55-01MR VCTF 3M SHL-Q2255-MR VCTF 3M SHL-Q2255-01MR VCTF 3M SHL-Q2155-MR VCTF 3M SHL-Q2155-01MR VCTF 3M SHL-W55-MR VCTF 3M SHL-W155-MR VCTF 3M − − SHL-W255-MR VCTF 3M SHL-W255-01MR VCTF 3M SHL-W2155-MR VCTF 3M SHL-W2155-01MR VCTF 3M SHL-W355-MR VCTF 3M SHL-D55-ML VCTF 3M SHL-Q2255-ML VCTF 3M − − SHL-Q2255-01ML VCTF 3M SHL-Q2155-ML VCTF 3M − SHL-W55-ML VCTF 3M − SHL-W155-ML VCTF 3M − SHL-W255-ML VCTF 3M SHL-W2155-ML VCTF 3M SHL-D55-MD VCTF 3M SHL-Q55-MD VCTF 3M SHL-Q2255-MD VCTF 3M − SHL-W2155-01ML VCTF 3M − − SHL-Q2255-01MD VCTF 3M SHL-Q2155-MD VCTF 3M − SHL-W55-MD VCTF 3M − SHL-W155-MD VCTF 3M − SHL-W255-MD VCTF 3M − SHL-W2155-MD VCTF 3M − SHL-W355-MD VCTF 3M − Operation Indicator Location of lead outle Actuator Plunger Panel mount plunger Panel mount roller plunger Right-hand Panel mount crossroller plunger Hinge lever Short hinge roller lever Hinge roller lever Micro load Model Model L3 SHL-D55-L3MR VCTF 3M L4 SHL-D55-L4MR VCTF 3M SHL-D55-01L3MR VCTF 3M − L3 SHL-Q55-L3MR VCTF 3M − L4 SHL-Q55-L4MR VCTF 3M − L2 SHL-Q2255-L2MR VCTF 3M L3 SHL-Q2255-L3MR VCTF 3M SHL-Q2255-01L3MR VCTF 3M L4 SHL-Q2255-L4MR VCTF 3M SHL-Q2255-01L4MR VCTF 3M L3 SHL-Q2155-L3MR VCTF 3M SHL-Q2155-01L3MR VCTF 3M L4 SHL-Q2155-L4MR VCTF 3M SHL-Q2155-01L4MR VCTF 3M L3 SHL-W155-L3MR VCTF 3M L3 SHL-W255-L3MR VCTF 3M L4 SHL-W255-L4MR VCTF 3M L3 SHL-W2155-L3MR VCTF 3M L4 SHL-W2155-L4MR VCTF 3M − − − SHL-W255-01L4MR VCTF 3M − SHL-W2155-01L4MR VCTF 3M − SHL-W355-L4MR VCTF 3M L3 SHL-Q2255-L3ML VCTF 3M L4 SHL-Q2255-L4ML VCTF 3M − L3 SHL-W55-L3ML VCTF 3M − L3 SHL-W155-L3ML VCTF 3M − L4 SHL-W155-L4ML VCTF 3M − L3 SHL-W255-L3ML VCTF 3M Short hinge lever Hinge lever Short hinge roller lever Panel mount roller plunger Underside Standard One-way action short hinge roller lever L4 Panel mount roller plunger Left-hand Type Voltage specification* Short hinge roller lever Hinge roller lever L4 − SHL-Q2255-01L3ML VCTF 3M − SHL-W255-01L4ML VCTF 3M L4 SHL-Q2255-L4MD VCTF 3M L3 SHL-W255-L3MD VCTF 3M SHL-Q2255-01L4MD VCTF 3M − L4 SHL-W255-L4MD VCTF 3M − L4 SHL-W2155-L4MD VCTF 3M − * Refer to Voltage rating for voltage specifications on page 6. 2 SHL Specifications Approved Standards Agency UL Standard UL508 CSA C22.2 No. 14 CSA File No. E76675 LR45746 TÜV Rheinland EN60947-5-1 J50062486 CCC (CQC) GB/T14048.5 Contact your OMRON representative for details. Approved models General-purpose models listed on page 1. All SHL models listed in this datasheet. Ask your OMRON representative for information on approved models. Approved Standard Ratings Ratings Rated voltage 125 VAC 250 VAC 480 VAC 8 VDC 14 VDC 30 VDC 125 VDC 250 VDC Inrush current Non-inductive load (A) Resistive Lamp load load NC NO NC NO 10 1.5 10 1.5 2 − 10 2 10 2 5 1.5 0.4 0.4 0.2 0.2 NC NO Inductive load (A) Inductive Motor load load NC NO NC NO 3 2.5 2 1.5 − − 5 2 5 2 1.5 1.5 0.05 0.05 0.03 0.03 15 A max. 15 A max. Note: 1. The above figures are for steady-state currents. 2. Inductive loads have a power factor of 0.4 min. (AC) and a time constant of 7 ms max. (DC). 3. Lamp load has an inrush current of 10 times the steady-state current. 4. Motor load has an inrush current of 6 times the steady-state current. Micro load models Rated voltage 125 VAC 8 VDC 14 VDC 30 VDC Non-inductive load (A) Resistive load NC NO 0.1 0.1 0.1 0.1 TÜV (EN60947-5-1), CCC (GB/T14048.5) Model Category and rating I the SHL-@55 AC-15 2 A/125 V DC-12 2 A/48 V 5A 5A SHL-@55-01 AC-14 0.1 A/125 V DC-12 0.1 A/48 V SHL-@55-L AC-15 2 A/125 V SHL-@55-01L AC-14 0.1 A/125 V 0.5 A 0.5 A SHL-@55-01L2 DC-12 0.1 A/12 V SHL-@55-L3 DC-12 2 A/24 V SHL-@55-01L3 DC-12 0.1 A/24 V SHL-@55-L4 DC-12 2 A/24 V SHL-@55-01L4 DC-12 0.1 A/24 V SHL-@55-L5 DC-12 2 A/48 V Between terminals of the same polarity Dielectric strength Between each terminal and non-current-carrying metal part Rated insulation voltage (Ui) Pollution degree (operating environment) Short-circuit protective device (SCPD) Conditional short-circuit current Conventional enclosed thermal current (Ithe) Protection against electric shock OFF reverse voltage Vibration resistance Malfunction Destruction Shock resistance Malfunction Ambient operating temperature Ambient operating humidity Weight *3 5A 0.5 A 5A 0.5 A 5A 0.5 A UL/CSA A300 Rated voltage 120 VAC 240 VAC Carry current 10 A Current (A) Make Break 60 6 30 3 Volt-amperes (V) Make Break 7,200 720 Engineering Data IP67 (EN60947-5-1) 10,000,000 operations min. 500,000 operations min. 0.1 mm/s to 0.5 m/s (hinge lever models) 120 operations/min 30 operations/min 50/60 Hz 100 MΩ min. (at 500 VDC) 15 mΩ max. (initial value for the built-in switch when tested alone) 1,000 VAC, 50/60 Hz for 1 min 2,000 VAC, 50/60 Hz for 1 min/Uimp at 2.5 kV (EN60947-5-1) 150 V (EN60947-5-1) 3 (EN60947-5-1) 10 A fuse type gI or gG (IEC60269) 100 A (EN60947-5-1) 5 A (EN60947-5-1) Class II (grounding not required with double insulation) 1,000 VAC max., 300 VDC max. (EN60947-5-1) 10 to 55 Hz, 1.5-mm double amplitude 1,000 m/s2 max. 300 m/s2 max. −10°C to +80°C (with no icing) 35% to 95%RH Approx. 62 to 72 g Electrical Durability (Ambient temperature: +5°C to +35°C, Ambient humidity: 40% to 50%RH) Durability (x 104 operations) Contact resistance 5A SHL-@55-01L5 DC-12 0.1 A/48 V Note: "AC-15 2 A/125 V" indicates the following. Application category: AC-16 Rated operating current (Ie): 2 A Rated operating voltage (Ue): 125 V Characteristics (For SHL-W155) Degree of protections *1 Mechanical Durability *2 Electrical Operating speed Mechanical Operating frequency Electrical Rated frequency Insulation resistance 0.5 A 0.5 A 1,000 700 500 Operating frequency: 30 operations/min. (cos dia. = 1) 300 250 VAC 100 70 50 30 10 7 5 3 1 0 1 2 3 4 5 6 7 8 9 10 Switching current (A) Note: 1. The figures at the left are initial values. 2. The ratings at the left may vary depending on the model. Contact your OMRON representative for further details. *1. The head section of the plunger type SHL-D(Q)@@ is excluded. *2. Durability values are calculated at an operating temperature of +5°C to +35°C, and an operating humidity of 40% to 70%RH. *3. The values are for the plunger-type models. 3 SHL Structure and Nomenclature Structure Contact Form Movable plunger (COM) 1 2 (NC) Rubber cap (NBR) 4 (NO) Die-cast case (zinc die-cast) Seal rubber (NBR) Common terminal (COM) Normally open terminal (NO) Terminal protection cover Normally closed Seal packing (NBR) terminal (NC) Dimensions and Operating Characteristics Switches (Unit: mm) (Note: Omitted dimensions are the same as those of the plunger models.) Plunger SHL-D55 SHL-D55-01 7.8 dia. * Two, 4.2 dia. holes PT 42.5 17.5 M14 × 1 Operating Characteristics 10 OP 19 16.9 16 9.6 3.5 16.5 ±0.2 Terminal protective cover Panel Mount Plunger SHL-Q55 SHL-Q55-01 13 15 × 15 45.6 54.6 Rubber seal Model SHL-D55 SHL-D55-01 Operating force Release force Pretravel Overtravel Movement Differential OF RF PT OT MD max. min. max. min. max. 9.81 N 1.96 N 1.5 mm 2 mm 0.5 mm Free Position Operating Position FP OP max. − 34±0.8 mm 73.5 * Stainless steel pin plunger 7.8 dia. * M14 × 1 PT Two hexagon nut (thickness: 2.5, width: 17) 10 OP 19 16.9 16 9.6 3.5 16.5 ±0.2 13 Model SHL-Q55 Operating Characteristics SHL-Q55-01 OF RF PT OT MD max. min. max. min. max. 9.81 N 1.96 N 1.5 mm 2 mm 0.5 mm FP OP max. − 34±0.8 mm 15 × 15 * Stainless steel pin plunger Panel Mount Roller Plunger SHL-Q2255 SHL-Q2255-01 11 dia. × 4.7 * PT M14 × 1 10 Two hexagon nut (thickness: 2.5 width: 17) OP 19 16.9 16 9.6 3.5 16.5 ±0.2 13 Model SHL-Q2255 Operating Characteristics SHL-Q2255-01 OF RF PT OT MD max. min. max. min. max. 9.81 N 1.96 N 1.5 mm 2 mm 0.5 mm FP OP max. − 43±0.8 mm 15 × 15 * Stainless sintered alloy roller Note: Unless otherwise specified, a tolerance of ±0.4 mm applies to all dimensions. 4 SHL Panel Mount Crossroller Plunger SHL-Q2155 SHL-Q2155-01 11 dia. × 4.7 * PT M14 × 1 10 Two hexagon nut (thickness: 2.5 width: 17) OP 19 16.9 16 9.6 3.5 13 16.5 ±0.2 Model SHL-Q2155 Operating Characteristics SHL-Q2155-01 OF RF PT OT MD max. min. max. min. max. 9.81 N 1.96 N 1.5 mm 2 mm 0.5 mm FP OP max. − 43±0.8 mm 15 × 15 * Stainless sintered alloy roller Short Hinge Lever SHL-W55 SHL-W55-01 t=1* 35R 6.8 42.5 16.5 Model SHL-W55 Operating Characteristics SHL-W55-01 13 17.5 24 16.9 FP 21 16 OP 16 9.6 3.5 13 16.5 ±0.2 OF RF PT OT MD max. min. max. min. max. 3.14 N 0.78 N 8 mm 3 mm 2.5 mm FP OP max. 29.5 mm 21.5±1 mm 15 × 15 * Stainless steel lever Hinge Lever SHL-W155 SHL-W155-01 t=1* 6.8 53R Model HL-W155 Operating Characteristics SHL-W155-01 17.5 FP 24 16.9 21 16 OP 16 9.6 3.5 16.5 ±0.2 13 OF RF PT OT MD max. min. max. min. max. 2.35 N 0.44 N 13 mm 5 mm 4 mm FP OP max. 34.5 mm 21.5±1 mm 15 × 15 * Stainless steel lever Short Hinge Roller Lever SHL-W255 SHL-W255-01 9.5 dia. × 4.8 * Model SHL-W255 Operating Characteristics SHL-W255-01 31 R 6.8 FP 24 16.9 OP 21 16 16 9.6 3.5 16.5 ±0.2 13 OF RF PT OT MD max. min. max. min. max. 3.92 N 0.78 N 8 mm 3 mm 2.5 mm FP OP max. 41 mm 33±1 mm 15 × 15 * Sintered stainless roller Hinge Roller Lever SHL-W2155 SHL-W2155-01 9.5 dia. × 4.0 * 6.8 Model SHL-W2155 Operating Characteristics SHL-W2155-01 R 51 FP 24 16.9 OP 21 16 16 9.6 3.5 16.5 ±0.2 13 OF RF PT OT MD max. min. max. min. max. 2.55 N 0.49 N 13 mm 5.5 mm 4 mm FP OP max. 46.5 mm 33.5±1 mm 15 × 15 * Sintered stainless roller Note: Unless otherwise specified, a tolerance of ±0.4 mm applies to all dimensions. 5 SHL R One-way Action Short Hinge Roller Lever SHL-W355 6.8 SHL-W355-01 Model SHL-W355 Operating Characteristics SHL-W355-01 90° 35.5 Operating direction 9.5 dia. × 4.0 * FP OP 24 16.9 21 16 16 9.6 3.5 16.5 ±0.2 13 OF RF PT OT MD max. min. max. min. max. 3.92 N 0.78 N 8 mm 3 mm 2.5 mm FP OP max. 52.5 mm 44.5± 1 mm 15 × 15 * Stainless sintered roller One-way Action Hinge Roller Lever SHL-W3155 SHL-W3155-01 9.5 dia. × 4.0 * Model SHL-W3155 Operating Characteristics SHL-W3155-01 90° 52 .5 R 6.8 Operating direction FP OP 24 16.9 21 16 16 9.6 3.5 16.5 ±0.2 13 OF RF PT OT MD max. min. max. min. max. 2.55 N 0.49 N 13 mm 5.5 mm 4 mm FP OP max. 57.5 mm 44.5±1 mm 15 × 15 * Stainless sintered roller Note: Unless otherwise specified, a tolerance of ±0.4 mm applies to all dimensions. Molded Terminal Models Operation Indicator-equipped Models Use of the molded terminal model is recommended in locations subject to excessive dust, oil drips, or moisture. The molded terminal model will have the same dimensions and operating characteristics as the basic model. The molded terminal model may be equipped with an operation indicator (neon lamp or LED) upon request to facilitate maintenance and inspection. The operation indicator is designed to illuminate when the Switch is not operating. (Because of the molded terminal model, any change to the Switch wiring cannot be made.) For DC • LED indicator is provided. • As a rectifier stack is incorporated, into the unit and no directionality exists for connection of + and −, this type can also be operated on AC. • The voltage specifications are given below. • Voltage ratings of LED indicators are as shown in the table below. MR ML Model MD Suffix by Location of Lead Outlet Location of lead outlet (Refer to above figure) Right-hand Left-hand Underside L2 L3 L4 Model (suffix) Terminal COM, NC, NO Voltage rating (V) 12 24 24 Contact Circuit -MR -ML -MD Leakage current (mA) Approx. 2.4 Approx. 2 Approx. 1.2 Internal resistance (kΩ) 4.3 10 18 Power supply Built-in switch Note: The above suffixes can be added to the model numbers given on page 1 to specify molded terminals. Load Lead Supplies Specifications Leads Nominal cross-sectional area (mm2) No. of conductors/cond. dia. External diameter (mm) Terminal connections Length (m) VCTF (Vinyl cabtire cable) Resistor 0.75 LED 30/0.18 3-conductor 7 dia. Black: COM White: NO Red: NC 3 (standard) 6 SHL Safety Precautions Refer to Safety Precautions for All Limit Switches. Precautions for Correct Use Operating Environment • Seal material may deteriorate if a Switch is used outdoor or where subject to special cutting oils, solvents, or chemicals. Always appraise performance under actual application conditions and set suitable maintenance and replacement periods. • Install Switches where they will not be directly subject to cutting chips, dust, or dirt. The Actuator and Switch must also be protected from the accumulation of cutting chips or sludge. Not Suitable • When mounting the Terminal Protective Cover to the case, align the cover on the case and then press the cover down to mount it firmly. If the cover is pressed down in an inclined position, rubber packing will deform and thus affect the sealing capability. Suitable Rubber packing Rubber packing Micro Load Models When using a Limit Switch for opening or closing micro-load circuit (zones 1 through 3), contact failure may occur if a Limit Switch with ordinary contact specifications is used. Therefore, when using Limit Switches in the micro-load range, use ones with contact specifications that are suited to each zone. Use the SHL-@-01 micro load models within the zones (1 through 3) shown in the following diagram. Micro Load Applicable Ranges Voltage (VDC) • Constantly subjecting a Switch to vibration or shock can result in wear, which can lead to contact interference with contacts, operation failure, reduced durability, and other problems. Excessive vibration or shock can lead to false contact operation or damage. Install Switches in locations not subject to shock and vibration and in orientations that will not produce resonance. • The Switches have physical contacts. Using them in environments containing silicon gas will result in the formation of silicon oxide (SiO2) due to arc energy. If silicon oxide accumulates on the contacts, contact interference can occur. If silicon oil, silicon filling agents, silicon cables, or other silicon products are present near the Switch, suppress arcing with contact protective circuits (surge killers) or remove the source of silicon gas. 5 mW 800 mW 0.16 mA 30 26 mA 24 Operating range for micro-load models Operating range for standard models Connections Be sure to connect a fuse with a breaking current 1.5 to 2 times the rated current to the Limit Switch in series in order to protect the Limit Switch from damage due to short-circuiting. When using the Limit Switch under the EN ratings, use a gI or gG 10A fuse that conforms to IEC60269. 12 Unusable range 5 1 mA 0 0.1 1 100 mA 160 mA 10 Mounting • Secure the Switch with two M4 screws and washers. The tightening torque applied to each terminal must be 1.18 to 1.37 N·m. Tighten the screws to the specified torque. An excessive tightening torque may damage the Switch and cause a malfunction. • When mounting the panel mount-type Switch with screws on a side surface, remove the hexagonal nuts from the actuator. Mounting Holes Two, 4.3-dia. or M4 screw holes The above diagram is for standard conditions (+5°C to +35°C, 40% to 70%RH). Since the values vary depending on the operating environment conditions, contact your OMRON representative for further details. Tightening Torque • A loose screw may result in a malfunction. Be sure to tighten each screw to the proper tightening torque as shown below. No. Type 1 Terminal screw (M3 screw) Mounting screw (M4 screw) 16.5 ± 0.2 • When mounting the panel mount type (SHL-Q55, SHL-Q2255, or SHL-Q2155) on a panel, tighten the hexagonal nuts of the actuator to a torque less than 4.90 to 7.84 N·m. Mounting Holes 14.5 +0.2 0 dia. 100 1,000 Current (mA) 2 Appropriate tightening torque 0.24 to 0.44 N·m 1.18 to 1.37 N·m • When wiring, use M3 round solderless terminals and apply insulation shielding to the connections. Tighten the terminals screws to 0.24 to 0.44 N·m. Operating Stroke Ensure that the operating stroke for roller plunger models is within the set position display. Operating stroke range Reference Others The standard seal rubber for the lead wire outlet is one that allows 6to 8-dia. cables. The appropriate nominal cross-section of the lead wire is 0.75 mm2. (When the sealing capability is required over a long period of time, use mold specifications.) 7 Terms and Conditions Agreement Read and understand this catalog. Please read and understand this catalog before purchasing the products. Please consult your OMRON representative if you have any questions or comments. Warranties. (a) Exclusive Warranty. Omron’s exclusive warranty is that the Products will be free from defects in materials and workmanship for a period of twelve months from the date of sale by Omron (or such other period expressed in writing by Omron). Omron disclaims all other warranties, express or implied. (b) Limitations. OMRON MAKES NO WARRANTY OR REPRESENTATION, EXPRESS OR IMPLIED, ABOUT NON-INFRINGEMENT, MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE OF THE PRODUCTS. BUYER ACKNOWLEDGES THAT IT ALONE HAS DETERMINED THAT THE PRODUCTS WILL SUITABLY MEET THE REQUIREMENTS OF THEIR INTENDED USE. Omron further disclaims all warranties and responsibility of any type for claims or expenses based on infringement by the Products or otherwise of any intellectual property right. (c) Buyer Remedy. Omron’s sole obligation hereunder shall be, at Omron’s election, to (i) replace (in the form originally shipped with Buyer responsible for labor charges for removal or replacement thereof) the non-complying Product, (ii) repair the non-complying Product, or (iii) repay or credit Buyer an amount equal to the purchase price of the non-complying Product; provided that in no event shall Omron be responsible for warranty, repair, indemnity or any other claims or expenses regarding the Products unless Omron’s analysis confirms that the Products were properly handled, stored, installed and maintained and not subject to contamination, abuse, misuse or inappropriate modification. Return of any Products by Buyer must be approved in writing by Omron before shipment. Omron Companies shall not be liable for the suitability or unsuitability or the results from the use of Products in combination with any electrical or electronic components, circuits, system assemblies or any other materials or substances or environments. Any advice, recommendations or information given orally or in writing, are not to be construed as an amendment or addition to the above warranty. See http://www.omron.com/global/ or contact your Omron representative for published information. Limitation on Liability; Etc. OMRON COMPANIES SHALL NOT BE LIABLE FOR SPECIAL, INDIRECT, INCIDENTAL, OR CONSEQUENTIAL DAMAGES, LOSS OF PROFITS OR PRODUCTION OR COMMERCIAL LOSS IN ANY WAY CONNECTED WITH THE PRODUCTS, WHETHER SUCH CLAIM IS BASED IN CONTRACT, WARRANTY, NEGLIGENCE OR STRICT LIABILITY. Further, in no event shall liability of Omron Companies exceed the individual price of the Product on which liability is asserted. Suitability of Use. Omron Companies shall not be responsible for conformity with any standards, codes or regulations which apply to the combination of the Product in the Buyer’s application or use of the Product. At Buyer’s request, Omron will provide applicable third party certification documents identifying ratings and limitations of use which apply to the Product. This information by itself is not sufficient for a complete determination of the suitability of the Product in combination with the end product, machine, system, or other application or use. Buyer shall be solely responsible for determining appropriateness of the particular Product with respect to Buyer’s application, product or system. Buyer shall take application responsibility in all cases. NEVER USE THE PRODUCT FOR AN APPLICATION INVOLVING SERIOUS RISK TO LIFE OR PROPERTY OR IN LARGE QUANTITIES WITHOUT ENSURING THAT THE SYSTEM AS A WHOLE HAS BEEN DESIGNED TO ADDRESS THE RISKS, AND THAT THE OMRON PRODUCT(S) IS PROPERLY RATED AND INSTALLED FOR THE INTENDED USE WITHIN THE OVERALL EQUIPMENT OR SYSTEM. Programmable Products. Omron Companies shall not be responsible for the user’s programming of a programmable Product, or any consequence thereof. Performance Data. Data presented in Omron Company websites, catalogs and other materials is provided as a guide for the user in determining suitability and does not constitute a warranty. It may represent the result of Omron’s test conditions, and the user must correlate it to actual application requirements. Actual performance is subject to the Omron’s Warranty and Limitations of Liability. Change in Specifications. Product specifications and accessories may be changed at any time based on improvements and other reasons. It is our practice to change part numbers when published ratings or features are changed, or when significant construction changes are made. However, some specifications of the Product may be changed without any notice. When in doubt, special part numbers may be assigned to fix or establish key specifications for your application. Please consult with your Omron’s representative at any time to confirm actual specifications of purchased Product. Errors and Omissions. Information presented by Omron Companies has been checked and is believed to be accurate; however, no responsibility is assumed for clerical, typographical or proofreading errors or omissions. 2022.4 In the interest of product improvement, specifications are subject to change without notice. OMRON Corporation Industrial Automation Company http://www.ia.omron.com/ (c)Copyright OMRON Corporation 2022 All Right Reserved.
SHL-Q55-01 价格&库存

很抱歉,暂时无法提供与“SHL-Q55-01”相匹配的价格&库存,您可以联系我们找货

免费人工找货
SHL-Q55-01
    •  国内价格 香港价格
    • 1+605.171151+77.61970
    • 5+565.613455+72.54600
    • 10+526.0557510+67.47230

    库存:0