Q124-E1-03.fm Page 1 Tuesday, May 30, 2006 5:22 PM
Electromagnetic Coupling RFID System
V600
Non-contact Data Communications System
• New compact, slim Controller with two input channels added to
the lineup.
• Superior environmental resistance.
• Heat-resistant Data Carrier available (150°C max.).
• Large memory capacity of 8 kbytes for Built-in-battery Data Carriers and 254 bytes for Battery-less Data Carriers.
• Built-in-battery Data Carriers have a battery life detecting function.
• Data of Battery-less Data Carriers with small memory capacity
can be overwritten 300,000 times at normal temperatures.
• Thin, compact, and low-cost Data Carriers are available.
• Transmission distance of 100 mm max.
• CE marking/FCC approvals.
Ordering Information
■ Data Carriers
Item
Large Memory
Capacity
Battery-less Data Carriers
Small Memory
Capacity
Model
Built-in-battery Data Car- V600-D8KR12
riers
Specifications/Design/Memory capacity
Rectangular compact
65 × 40 × 15 mm
V600-D8KR13
Thin rectangular
86 × 54 × 10.3 mm
V600-D8KR04
Intermediate-range rectangular
86 × 54 × 20 mm
V600-D8KF04
Intermediate-range rectangular
86 × 54 × 20 mm
8 Kbytes
Replaceable-battery Data V600-D2KR16
Carriers
Compact
65 × 40 × 5 mm
2 Kbytes
Battery-less Data Carriers
V600-D23P71
Ultrathin card-type
86 × 54 × 1.5 mm
254 bytes
V600-D23P72
Thin half-size card-type
50 × 34 × 1.5 mm
V600-D23P66N
Rectangular
34 × 34 × 3.5 mm
V600-D23P66SP
Rectangular package with PFA
95 × 36.5 × 6.5 mm
V600-D23P61
Rectangular compact
32 × 24 × 6 mm
V600-D23P53
Round super-compact
8 dia. × 5 mm
V600-D23P54
Round compact
12 dia. × 6 mm
V600-D23P55
Round super-compact
8 dia. × 5 mm
Electromagnetic Coupling RFID System V600
1
Q124-E1-03.fm Page 2 Tuesday, May 30, 2006 5:22 PM
■ R/W Heads
Item
Model
Rectangular type
Specifications/Design
Dimensions: 100 × 100 × 30 mm
V600-H07 (0.5 m)
2-m cable
V600-H07 (5 m)
5-m cable
V600-H07 (10 m)
10-m cable
Dimensions: 53 × 40 × 23 mm
V600-H11 (0.5 m)
0.5-m cable
V600-H11-R (0.5 m)
0.5-m cable
V600-H11 (2 m)
2-m cable
V600-H11 (5 m)
5-m cable
V600-H11 (10 m)
Cylinder type
10-m cable
Dimensions: 22 dia. × 80 mm
V600-H51 (0.5 m)
0.5-m cable
V600-H51 (2 m)
2-m cable
V600-H51 (5 m)
5-m cable
V600-H51 (10 m)
10-m cable
Dimensions: 22 dia. × 85 mm
V600-H52 (0.5 m)
0.5-m cable
V600-H52 (2 m)
2-m cable
V600-H52 (5 m)
5-m cable
V600-H52 (10 m)
Separate-amplifier
type
Amplifier
section
Sensor
section
0.5-m cable
V600-H07 (2 m)
10-m cable
V600-HA51 (2 m)
73.8 × 22.6 × 36.5 mm, with 2-m cable
V600-HA51 (5 m)
73.8 × 22.6 × 36.5 mm, with 5-m cable
V600-HA51 (10 m)
73.8 × 22.6 × 36.5 mm, with 10-m cable
V600-HS51
12 dia. × 35 mm deep, with 2-m cable
V600-HS61
30.5 × 18 × 10 mm, with a 2-m cable
■ ID Controllers
Item
Model
DC Power Supply
DC Power Supply
Specifications/Design
V600-CA5D02
24 VDC
Two R/W Head channels
105 × 90 × 65 mm
V600-CD1D-V3
24 VDC
RS-232C host interface
Single R/W Head connectable
115 × 68 × 80 mm
V600-CM1D
24-VDC, 5-VDC 2-system
input
Single R/W Head connectable
Board type
V600-IDSC02
24 VDC
RS-232C interface
POWER
1
IN
2
3
OUT
4
1
5
2
3
MAON
No.
X10
DC24V
INPUT
TEST
ON
HEAD1
Host RS-232C, RS-422,
and RS-485 interfaces
Two R/W Heads connectable
HEAD2
V600-IDSC04
POWER
1
IN
2
OUT
4
1
5
2
3
3
MAON
No.
X10
MAON
No.
X10
DC24V
INPUT
TEST
TEST
ON
ON
HEAD1
HEAD1
HEAD2
HEAD2
2
Electromagnetic Coupling RFID System V600
Four R/W Heads connectable
Q124-E1-03.fm Page 3 Tuesday, May 30, 2006 5:22 PM
■ Accessories (Order Separately)
Item
Model
Extension cable for
R/W Heads
V600-A45
Specifications/Design
Standard cable
Non-water-resistant connectors
V600-A44
V600-A40
10-m cable
V600-A41
20-m cable
V600-A42
30-m cable
V600-A56
Robotic cable
Non-water-resistant connectors
V600-A55
Attachment
Model
10-m cable
20-m cable
30-m cable
V600-A81
For the V600-D2KR16
*Mount with M3 flat countersunk head screws (at least two).
V600-A84
For the V600-D23P71/D23P72
Ultrasonic deposition can be used on the plastic container.
V600-A86
For the V600-D23P66N
Cable length
2m
XW2Z-500S
5m
5-m cable
V600-A51
■ RS-232C Cables (Order
Separately)
XW2Z-200S
3-m cable
V600-A50
V600-A52
Holder
3-m cable
5-m cable
Compatible ID Controllers
V600-CD1D-V3
V600-CM1D
■ Connectors for ID Controllers
(One Set per Unit)
Model
Name
XM2A-0901
Connector
Plug
XM2S-0911
Connector
Hood
Compatible ID Controllers
V600-CD1D-V3
V600-CM1D
V600-CA5D02
MC1.5/5-STF-3.5 RS-422/
(made by Phoenix RS-485
communicaContact)
tions
connector
Electromagnetic Coupling RFID System V600
3
Q124-E1-03.fm Page 4 Tuesday, May 30, 2006 5:22 PM
Specifications
■ Battery-less Data Carriers with Small Memory Capacity
Shape
Ultrathin
Card-type
Ultrathin
Half-size
Card-type
Rectangular
Compact
Chemicalresistant
Rectangular
Compact
Round
Supercompact
Round
Compact
Round
Supercompact
Model
V600D23P71
V600D23P72
V600D23P66N
V600D23P66SP
V600D23P61
V600D23P53
V600D23P54
V600D23P55
Item
Memory capacity
254 bytes
Memory type
EEPROM (non-volatile memory)
Transmission distance
Refer to “Transmission Distance Specifications for Battery-less Data Carriers with Small Memory Capacity” on
page 10.
Data retention time
(after writing data)
10 years
Number of
overwrites
(per address)
(Refer to
separate
item for
ambient
temperature)
10 years (−40 10 years
to 110°C)
1 year (−40 to
150°C)
10 years (−40
to 110°C)
1 year (−40 to
150°C)
Up to 0°C 800,000 times
Up to
25°C
400,000 times
Up to
60°C
300,000 times
Up to
85°C
100,000 times
Transmission error
detection
16-bit CRC in both directions (CRC: Cyclic Redundancy Check)
Ambient
temperature
For data
storage
−20 to 110°C
−40 to 150°C −40 to 110°C −40 to 85°C
(See note.)
−40 to 150°C
(See note.)
For
reading/
writing
−10 to 70°C
−20 to 85°C
−25 to 85°C
Storage temperature
−20 to 110°C
−40 to 150°C −40 to 110°C −40 to 85°C
(See note.)
−40 to 150°C
(See note.)
Ambient humidity
Operating: 35% to 95%
Degree of protection
IEC 60529: IP67
IEC 60529:
IP68
IEC 60529:
IP67
Vibration resistance
(destruction)
10 to 2,000 Hz, 3.0-mm
double amplitude, 300 m/s2
acceleration for 30 min
each in 3 directions (90 min
total)
10 to 2,000 Hz, 10 to 2,000 Hz, 3.0-mm double amplitude, 300 m/s2 accel1.5-mm double eration for 30 min each in 3 directions (90 min total)
amplitude,
150 m/s2 acceleration 10
times each in 3
directions (15
min)
Shock resistance
(destruction)
1,000 m/s 2 3 times each in 3 500 m/s2 3
1,000 m/s2 3 times each in 3 directions (18 times total)
times each in 3
directions (18 times total)
Weight
Approx. 15 g Approx. 5 g
−20 to 70°C
IEC 60529:
IP67
directions (18
times total)
−25 to 70°C
IEC 60529: IP67
10 to 2,000 Hz,
1.5-mm double
amplitude,
150 m/s2 acceleration 10
times each in 3
directions (15
min)
500 m/s2 3
times each in 3
directions (18
times total)
Approx 6.5 g Approx. 19 g Approx. 5.8 g Approx. 0.4 g Approx. 1.0 g Approx. 0.6 g
Note: The 150°C heat resistance was confirmed by leaving the Unit at 150°C for 1,000 continuous hours, and by a thermal shock test consisting
of 1,000 −10°C/150°C cycles of 30 min each. No defect was found among the 22 test samples.
4
Electromagnetic Coupling RFID System V600
Q124-E1-03.fm Page 5 Tuesday, May 30, 2006 5:22 PM
■ Data Carriers with Large Memory Capacity
Shape
Model
Battery-less
Replaceable-battery
Rectangular
Compact
Rectangular Thin
Built-in-battery
Rectangular
Intermediate Range
Rectangular
Intermediate Range
Rectangular
Compact with
Replaceable Battery
V600-D8KR12
V600-D8KR13
V600-D8KR04
V600-D8KF04
V600-D2KR16
Item
Memory capacity
8 KB
Memory type
SRAM (volatile memory)
2 KB
FeRAM
(nonvolatile memory)
SRAM
(volatile memory)
Transmission distance Refer to “Transmission Distance Specifications for Data Carriers with Large Memory Capacity (Built-in-battery/Batteryless/Replaceable-battery)” on page 15
Battery life (See note
1.)
Refer to “Battery Life” on page 22
Number of reads/writes Unlimited
--- (See note 4.)
2 years (at 25°C)
(See note 2.)
1,000 million
Unlimited (Does not
affect battery life)
Transmission error
detection
16-bit CRC in both directions (CRC: Cyclic Redundancy Check)
Ambient
For data
temperature storage
−40 to 70°C
−15 to 70°C
For
reading/
writing
−25 to 70°C
0 to 50°C
Storage temperature
−40 to 70°C
−15 to 70°C
Ambient humidity
35% to 95%
35% to 85%
Storage humidity
35% to 95%
Degree of protection
IEC 60529: IP67
Vibration resistance
(destruction)
10 to 500 Hz, 1.0-mm single amplitude, 150 m/s2 acceleration with 3 sweeps of 11 min each in 10 to 150 Hz, 0.75-mm
single amplitude, 100X, Y, and Z directions
m/s2 acceleration for
30 min each in X, Y,
and Z directions
Shock resistance
(destruction)
1,000 m/s2 3 times each in X, Y, and Z directions (18 times total)
500 m/s2 3 times each 300 m/s2 3 times each
in X, Y, and Z direcin X, Y, and Z directions (18 times total)
tions (18 times total)
Weight
Approx. 70 g
Approx. 150 g
IEC 60529: IP50 (dustproof) (See note 3.)
Approx. 160 g
Approx. 15 g
Note: 1. A low battery detection function is built-in.
2. The battery life is applicable for batteries used at a temperature of 25°C. Refer to “Temperature and Battery Life” on page 22 for details
on the relationship between temperature and battery life. The lithium battery is commercially available (CR2016).
3. The Data Carrier is dustproof when the provided battery replacement cover seal is used.
4. Data holding time: 10 years
Electromagnetic Coupling RFID System V600
5
Q124-E1-03.fm Page 6 Tuesday, May 30, 2006 5:22 PM
■ Read/Write (R/W) Heads with Built-in Amplifier
Model
V600-H07
V600-H11/H11-R
V600-H51
V600-H52
Item
Oscillation frequency
530 kHz
Ambient temperature
−25 to 70°C
−10 to 60°C
Storage temperature
−40 to 85°C
−25 to 75°C
Ambient humidity
35% to 95%
Storage humidity
35% to 95%
Insulation resistance
50 MΩ min. (at 500 VDC) between cable terminals and case
Dielectric strength
1,000 VAC, 50/60 Hz for 1 min between cable terminals and case (Leakage current: 1 mA max.)
Degree of protection
IEC 60529: IP67
Vibration resistance
(destruction)
10 to 500 Hz, 1.0-mm single amplitude, 150 m/s2 acceleration with 3 sweeps of 11 min each in X, Y, and Z directions
Shock resistance
Destruction: 500 m/s2 3 times each in X, Y, and Z directions (18 times total)
Cable length (See note 1.) Standard lengths of 0.5 m, 2 m, 5 m, and 10 m.
Wireless transmission
error detection
16-bit CRC in both directions (CRC: Cyclic Redundancy Check)
Indicators
Power: green; transmission: orange
Weight
Approx. 1 kg
(with 10-m cable)
Approx. 650 g (with 10-m cable)
Note: 1. Extension cables are also available. The maximum cable length is 30.5 m for the V600-H07 and 50.5 m for the V600-H11/H51/H52.
2. The connectors are not water-resistant.
6
Electromagnetic Coupling RFID System V600
Q124-E1-03.fm Page 7 Tuesday, May 30, 2006 5:22 PM
■ Read/Write (R/W) Heads with Separate Amplifier
Model
Sensor section
V600-HS51
Amplifier section
V600-HS61
V600-HA51
Item
Oscillation frequency
530 kHz
Ambient temperature
−10 to 60°C
---
Storage temperature
−25 to 75°C
Ambient humidity
35% to 95%
Insulation resistance
50 MΩ min. (at 500 VDC) between cable terminals and case
Dielectric strength
1,000 VAC 50/60 Hz for 1 min between cable terminals and case (Leakage current: 1 mA max.)
Degree of protection
IEC 60529: IP67
Vibration resistance
(destruction)
10 to 2,000 Hz, 1.5-mm single amplitude, 300 m/s accel- Installed in panel
eration with 2 sweeps of 15 min each in 3 directions
IEC 60529: IP66
2
DIN Track installation
10 to 2,000 Hz, 1.5-mm single amplitude, 300-m/s2 acceleration with 2
sweeps of 11 min each in 3 directions
10 to 500 Hz, 1.0-mm single amplitude, 150-m/s2 acceleration with 3
sweeps of 11 min each in 3 directions
Shock resistance
(destruction)
1,000 m/s2 3 times each in 3 directions (18 times total)
500 m/s2 3 times each in 3 directions (18 times total)
Cable length Sensor to
amplifier
2 m (fixed)
---
Amplifier to --controller
Standard lengths of 2 m, 5 m, and 10 m (See note 1.)
Wireless transmission
error detection
16-bit CRC in both directions (CRC: Cyclic Redundancy Check)
Indicators
---
Power: green; transmission: orange
Weight
Approx. 70 g (with 2-m cable)
Approx. 650 g (with 10-m cable)
Note: 1. Extension cables are also available. The maximum cable length is 50 m for the V600-HA51. Extension cables are not available for the
V600-HS51/HS61.
2. The connectors are not water-resistant.
Electromagnetic Coupling RFID System V600
7
Q124-E1-03.fm Page 8 Tuesday, May 30, 2006 5:22 PM
■ ID Controllers
Series
V600 Series
Model
V600-CA5D02
V600-CD1D-V3
V600-CM1D
Item
Host interface
RS-232C, RS-422, RS-485
RS-232C
Possible number of R/W 2
Heads
1
Power supply voltage
24 VDC
24 VDC, 5 VDC
Acceptable power supply 20.4 to 26.4 VDC
voltage
20.4 to 26.4 VDC
20.4 to 26.4 VDC
4.5 to 5.5 VDC
Power consumption
15 W max.
7.2 W max.
24 VDC: 7.2 W max.
5 VDC: 1.5 W max.
Insulation resistance
50 MΩ min. (at 500 VDC) between power terminals and case, between I/O terminals and case, or between the power
supply terminals and I/O terminals
Dielectric strength
1,000 VAC, 50/60 Hz for 1 min between the points listed above;
Leakage current: 10 mA max.
Noise immunity
1,500-V (p-p) pulses of 100-ns to 1-µs pulse width with a 1-ns rise time
Vibration
resistance
24 VDC
Destruction ---
1,000 VAC, 50/60 Hz for 1 min between the points listed above;
Leakage current: 10 mA max.
10 to 150 Hz, 0.3-mm double amplitude for 32 min each in X, Y, and Z directions
Malfunction 10 to 150 Hz, 0.2-mm double ampli- 10 to 150 Hz, 0.2-mm double amplitude for 32 min each in X, Y, and Z directude, 15 m/s2 acceleration 10 times for tions
8 min each in 3 directions
Shock
resistance
Destruction ---
Destruction: 200 m/s2 3 times each in X, Y, and Z directions (18 times total)
Malfunction 150 m/s 3 times each in X, Y, and Z
directions (18 times total)
2
Ambient temperature
−10 to 55°C
Ambient humidity
35% to 85% (with no condensation)
--0 to 50°C
Operating conditions
No corrosive gases
Storage temperature
−25 to 65°C
Memory back-up
A capacitor backs up the most recent Memory backup is not available. Error details, however, can be read from the
error data and statistical error data for personal computer when the power is turned ON.
up to 20 days (at 25°C) after a power
interruption.
Diagnostic functions
Checks for CPU errors, memory errors, power interruptions, and transmission errors
Ground
Ground to 100 Ω or less.
Degree of protection
IEC 60529: IP30 (panel mounted)
Weight
Approx. 300 g
8
−15 to 70°C
Approx 360 g
Electromagnetic Coupling RFID System V600
Approx. 180 g
Q124-E1-03.fm Page 9 Tuesday, May 30, 2006 5:22 PM
■ V600-IDSC
Series
V600-IDSC Series
Model
V600-IDSC02
V600-IDSC04
POWER
POWER
1
IN
1
IN
2
OUT
4
1
5
2
4
1
5
2
3
3
MAON
No.
X10
MAON
No.
X10
INPUT
TEST
TEST
TEST
ON
ON
Item
MAON
No.
X10
DC24V
DC24V
INPUT
2
3
3
OUT
ON
HEAD1
HEAD1
HEAD1
HEAD2
HEAD2
HEAD2
Host interface
RS-232C
Possible number of R/W Heads
2
Power supply voltage
24 VDC
Acceptable power supply voltage
19.2 to 28.8 VDC
Power consumption
50 W max.
Insulation resistance
20 MΩ min. (at 500 VDC) between power supply terminals and frame ground terminals
Dielectric strength
1,000 VAC, 50/60 Hz for 1 min between power supply terminals and frame ground terminals with a detected current of10 mA max.
Vibration resistance
10 to 50 Hz, 0.075-mm amplitude, 57 to 150 Hz, 9.8 m/s2 acceleration for 10 sweeps each in X, Y, and Z
directions
Shock resistance
147 m/s2 3 times each in X, Y, and Z directions
Ambient temperature
0 to 55°C (with no icing)
Ambient humidity
10% to 90% (with no condensation)
4
Storage temperature
−20 to 75°C (with no icing)
Storage humidity
10% to 90% (with no condensation)
Ground
Ground to 100 Ω or less.
Ground to 100 Ω or less.
Construction
Installed in panel
Installed in panel
Weight
Approx. 700 g
Approx. 800 g
Electromagnetic Coupling RFID System V600
9
Q124-E1-03.fm Page 10 Tuesday, May 30, 2006 5:22 PM
■ Transmission Distance Specifications for Battery-less Data Carriers
with Small Memory Capacity
Recommended combinations
Data Carrier
V600-D23P71
Installation
R/W Head
V600-H07
Stationary
Read distance
Controller
mode
Irrelevant
Transmission
distance
Condition for DC and R/W head
installation
10 to 70 mm (max. axi- These Data Carriers are for installaal offset ±10 mm)
tion on non-metallic surfaces only.
Write distance
Moving
R/W Head
Read distance
30 to 60 mm (max. axial offset ±10 mm)
Write distance
V600-H11/-H11-R
Stationary
Read distance
Iron
Non-metallic
Irrelevant
(Resin, plastic, wood, etc.)
5 to 40 mm (max. axial
offset ±10 mm)
Data transmission will be impossible if the DC is installed directly on
a metal surface. Refer to the V600
R/W Heads and EEPROM Data
15 to 40 mm (max. axi- Carriers Operation Manual (Cat.
al offset ±10 mm)
No. Z128) for details.
Irrelevant
10 to 50 mm (max. axial offset ±10 mm)
Write distance
Moving
V600-D23P71/72
Data Carrier
Read distance
Write distance
V600-D23P72
V600-H07
Stationary
Read distance
Write distance
Moving
Read distance
30 to 40 mm (max. axial offset ±10 mm)
Write distance
V600-H11/-H11-R
Stationary
Read distance
Irrelevant
5 to 30 mm (max. axial
offset ±10 mm)
Write distance
Moving
Read distance
15 to 30 mm (max. axial offset ±10 mm)
Write distance
Note: 1. The transmission distance/transmission time priority mode setting can be made using the lower-level transmission mode setting switch
or memory switch only with a Serial-interface Controller or ID Sensor Unit.
2. With Parallel-interface Controllers, the mode setting is always transmission distance priority.
3. The specifications take fluctuations in ambient temperature and slight differences between products into account.
10
Electromagnetic Coupling RFID System V600
Q124-E1-03.fm Page 11 Tuesday, May 30, 2006 5:22 PM
Recommended combinations
Data Carrier
Installation
R/W Head
V600-D23P66N V600-H07
Stationary
Moving
Read distance
Stationary
Moving
V600D23P66SP
V600-H07
Stationary
Moving
V600-H11/-H11-R
Stationary
Moving
Transmission
distance
Condition for DC and R/W head
installation
Transmission
5 to 45 mm (max. axial
distance priority offset ±10 mm)
R/W Head
Data Carrier
Transmission
time priority
5 to 35 mm (max. axial
offset ±10 mm)
Write distance
Irrelevant
5 to 35 mm (max. axial
offset ±10 mm)
Read distance
Transmission
25 to 40 mm (max. axiData transmission will be impossidistance priority al offset ±10 mm)
ble if the DC is installed directly on
Transmission
25 to 30 mm (max. axia metal surface. Refer to the V600
time priority
al offset ±10 mm)
R/W Heads and EEPROM Data
Irrelevant
25 to 30 mm (max. axi- Carriers Operation Manual (Cat.
al offset ±10 mm)
No. Z128) for details.
Transmission
5 to 30 mm (max. axial
distance priority offset ±10 mm)
Write distance
V600-H11/-H11-R
Controller
mode
Read distance
Transmission
time priority
5 to 25 mm (max. axial
offset ±10 mm)
Write distance
Irrelevant
5 to 25 mm (max. axial
offset ±10 mm)
Read distance
Transmission
15 to 25 mm (max. axidistance priority al offset ±10 mm)
Transmission
time priority
15 to 20 mm (max. axial offset ±10 mm)
Write distance
Irrelevant
15 to 20 mm (max. axial offset ±10 mm)
Read distance
Transmission
5 to 40 mm (max. axial
distance priority offset ±10 mm)
Transmission
time priority
5 to 30 mm (max. axial
offset ±10 mm)
Write distance
Irrelevant
5 to 30 mm (max. axial
offset ±10 mm)
Read distance
Transmission
20 to 40 mm (max. axidistance priority al offset ±10 mm)
Transmission
time priority
20 to 30 mm (max. axial offset ±10 mm)
Write distance
Irrelevant
20 to 30 mm (max. axial offset ±10 mm)
Read distance
Transmission
5 to 25 mm (max. axial
distance priority offset ±10 mm)
Transmission
time priority
5 to 20 mm (max. axial
offset ±10 mm)
Write distance
Irrelevant
5 to 20 mm (max. axial
offset ±10 mm)
Read distance
Transmission
10 to 25 mm (max. axidistance priority al offset ±10 mm)
Write distance
Transmission
time priority
10 to 20 mm (max. axial offset ±10 mm)
Irrelevant
10 to 20 mm (max. axial offset ±10 mm)
Iron
Non-metallic
(Resin, plastic, wood, etc.)
Note: 1. The transmission distance/transmission time priority mode setting can be made using the lower-level transmission mode setting switch
or memory switch only with a Serial-interface Controller or ID Sensor Unit.
2. With Parallel-interface Controllers, the mode setting is always transmission distance priority.
3. The specifications take fluctuations in ambient temperature and slight differences between products into account.
Electromagnetic Coupling RFID System V600
11
Q124-E1-03.fm Page 12 Tuesday, May 30, 2006 5:22 PM
Recommended combinations
Data Carrier
V600-D23P61
Installation
R/W Head
V600-H11/-H11-R
Stationary
Moving
V600-H51
Stationary
Read distance
Controller
mode
Transmission
time priority
2 to 16 mm (max. axial
offset ±10 mm)
Write distance
Irrelevant
2 to 16 mm (max. axial
offset ±10 mm)
Read distance
Transmission
12 to 19 mm (max. axidistance priority al offset ±10 mm)
Transmission
time priority
12 to 16 mm (max. axial offset ±10 mm)
Write distance
Irrelevant
12 to 16 mm (max. axial offset ±10 mm)
Read distance
Transmission
1 to 16 mm (max. axial
distance priority offset ±10 mm)
Write distance
Read distance
Write distance
Condition for DC and R/W head
installation
Transmission
2 to 19 mm (max. axial These Data Carriers can be indistance priority offset ±10 mm)
stalled on metallic surfaces.
Transmission
time priority
Moving
Transmission
distance
1 to 14 mm (max. axial
offset ±10 mm)
V600-D23P61
Data Carrier
V600-H51
R/W Head
Iron
Iron (SC, SS)
V600-H11
R/W Head
V600-D23P61
Data Carrier
Iron
Iron (SC, SS)
1 to 14 mm (max. axial The listed transmission distances
also apply for installation on nonoffset ±10 mm)
metallic surfaces. Refer to the V600
Transmission
7 to 16 mm (max. axial
R/W Heads and EEPROM Data
distance priority offset ±10 mm)
Carriers Operation Manual (Cat.
Transmission
7 to 14 mm (max. axial No. Z128) for details.
time priority
offset ±10 mm)
Irrelevant
Irrelevant
7 to 14 mm (max. axial
offset ±10 mm)
Note: 1. The transmission distance/transmission time priority mode setting can be made using the lower-level transmission mode setting switch
or memory switch only with a Serial-interface Controller or ID Sensor Unit.
2. With Parallel-interface Controllers, the mode setting is always transmission distance priority.
3. The specifications take fluctuations in ambient temperature and slight differences between products into account.
12
Electromagnetic Coupling RFID System V600
Q124-E1-03.fm Page 13 Tuesday, May 30, 2006 5:22 PM
Recommended combinations
Data Carrier
V600-D23P53
Installation
R/W Head
V600-HS51
(See note 4.)
Stationary
Read distance
Write distance
V600-HS61
(See note 4.)
Stationary
Read distance
Write distance
V600-H52
V600-D23P54
V600-HS51
(See note 4.)
V600-HS61
(See note 4.)
V600-H52
Stationary
Stationary
Stationary
Stationary
Controller
mode
Transmission
distance
0.5 to 4.0
Transmission
distance priority mm (max.
axial offset
±2 mm)
0.5 to 4.5
mm (max.
axial offset
±1 mm)
Transmission
time priority
0.5 to 3.0
mm (max.
axial offset
±2 mm)
0.5 to 3.5
mm (max.
axial offset
±1 mm)
Irrelevant
0.5 to 3.0
mm (max.
axial offset
±2 mm)
0.5 to 3.5
mm (max.
axial offset
±1 mm)
0.5 to 4.0
Transmission
distance priority mm (max.
axial offset
±2 mm)
0.5 to 4.5
mm (max.
axial offset
±1 mm)
Transmission
time priority
0.5 to 3.0
mm (max.
axial offset
±2 mm)
0.5 to 3.5
mm (max.
axial offset
±1 mm)
0.5 to 3.0
mm (max.
axial offset
±2 mm)
0.5 to 3.5
mm (max.
axial offset
±1 mm)
Irrelevant
0.5 to 4.0
Transmission
distance priority mm (max.
axial offset
±2 mm)
0.5 to 4.5
mm (max.
axial offset
±1 mm)
Transmission
time priority
0.5 to 3.0
mm (max.
axial offset
±2 mm)
0.5 to 3.5
mm (max.
axial offset
±1 mm)
Write distance
Irrelevant
0.5 to 3.0
mm (max.
axial offset
±2 mm)
0.5 to 3.5
mm (max.
axial offset
±1 mm)
Read distance
0.5 to 6.0
Transmission
distance priority mm (max.
axial offset
±2 mm)
0.5 to 6.5
mm (max.
axial offset
±1 mm)
Transmission
time priority
0.5 to 5.5
mm (max.
axial offset
±2 mm)
0.5 to 6.0
mm (max.
axial offset
±1 mm)
Write distance
Irrelevant
0.5 to 5.0
mm (max.
axial offset
±2 mm)
0.5 to 5.5
mm (max.
axial offset
±1 mm)
Read distance
0.5 to 6.5
Transmission
distance priority mm (max.
axial offset
±2 mm)
0.5 to 7.0
mm (max.
axial offset
±1 mm)
Transmission
time priority
0.5 to 5.5
mm (max.
axial offset
±2 mm)
0.5 to 6.0
mm (max.
axial offset
±1 mm)
Write distance
Irrelevant
0.5 to 5.5
mm (max.
axial offset
±2 mm)
0.5 to 6.0
mm (max.
axial offset
±1 mm)
Read distance
0.5 to 6.5
Transmission
distance priority mm (max.
axial offset
±2 mm)
0.5 to 7.0
mm (max.
axial offset
±1 mm)
Transmission
time priority
0.5 to 5.5
mm (max.
axial offset
±2 mm)
0.5 to 6.0
mm (max.
axial offset
±1 mm)
Irrelevant
0.5 to 5.5
mm (max.
axial offset
±2 mm)
0.5 to 6.0
mm (max.
axial offset
±1 mm)
Read distance
Write distance
Condition for DC and R/W head
installation
These Data Carriers are for flush
mounting in metallic bases only.
V600-D23P53/54
V600-HS61 Data Carrier
R/W Head
Iron
Iron
(SC, SS)
V600-D23P53/54
Data Carrier
V600-HS51
R/W Head
Iron
Iron(SC, SS)
V600-D23P53/54
Data Carrier
V600-H52
R/W Head
Iron
Iron(SC, SS)
The listed transmission distances
also apply for installation on nonmetallic surfaces. Refer to the V600
R/W Heads and EEPROM Data
Carriers Operation Manual (Cat.
No. Z128) for details.
Note: 1. The transmission distance/transmission time priority mode setting can be made using the lower-level transmission mode setting switch
or memory switch only with a Serial-interface Controller or ID Sensor Unit.
2. With Parallel-interface Controllers, the mode setting is always transmission distance priority.
3. The specifications take fluctuations in ambient temperature and slight differences between products into account.
4. This is the transmission distance when using the V600-HS@1 and V600-HA51 combination.
Electromagnetic Coupling RFID System V600
13
Q124-E1-03.fm Page 14 Tuesday, May 30, 2006 5:22 PM
Recommended combinations
Data Carrier
V600-D23P55
Installation
R/W Head
V600-HS51
(See note 4.)
Stationary
Read distance
Controller
mode
Transmission
0.5 to 6.5 mm (max.
distance priority axial offset ±2 mm)
Transmission
time priority
Write distance
Stationary
Read distance
Stationary
Read distance
0.5 to 6.0 mm (max.
axial offset ±2 mm)
V600-HS51
R/W Head
Iron
0.5 to 6.0 mm (max.
axial offset ±2 mm)
Non-metallic
(Resin, plastic, wood, etc.)
0.5 to 6.0 mm (max.
axial offset ±2 mm)
V600-D23P55
Data Carrier
V600-HS61
R/W Head
Transmission
0.5 to 9.0 mm (max.
distance priority axial offset ±2 mm)
Transmission
time priority
Write distance
V600-D23P55
Data Carrier
Transmission
0.5 to 7.0 mm (max.
distance priority axial offset ±2 mm)
Transmission
time priority
V600-H52
These Data Carriers are for flush
mounting in non-metallic bases
only.
Transmission
0.5 to 7.0 mm (max.
distance priority axial offset ±2 mm)
Transmission
time priority
Write distance
0.5 to 6.0 mm (max.
axial offset ±2 mm)
Condition for DC and R/W head
installation
Transmission
0.5 to 6.5 mm (max.
distance priority axial offset ±2 mm)
Transmission
time priority
V600-HS61
(See note 4.)
Transmission
distance
0.5 to 8.5 mm (max.
axial offset ±2 mm)
Transmission
0.5 to 8.5 mm (max.
distance priority axial offset ±2 mm)
Transmission
time priority
Iron
Non-metallic
(Resin, plastic, wood, etc.)
0.5 to 8.5 mm (max.
axial offset ±2 mm)
V600-D23P55
Data Carrier
V600-H52
R/W Head
Iron
Non-metallic
(Resin, plastic, wood, etc.)
The transmission distance decreases considerably when flush mounted in non-metallic bases. Refer to
the V600 R/W Heads and EEPROM
Data Carriers Operation Manual
(Cat. No. Z128) for details.
Note: 1. The transmission distance/transmission time priority mode setting can be made using the lower-level transmission mode setting switch
or memory switch only with a Serial-interface Controller or ID Sensor Unit.
2. With Parallel-interface Controllers, the mode setting is always transmission distance priority.
3. The specifications take fluctuations in ambient temperature and slight differences between products into account.
4. This is the transmission distance when using the V600-HS@1 and V600-HA51 combination.
14
Electromagnetic Coupling RFID System V600
Q124-E1-03.fm Page 15 Tuesday, May 30, 2006 5:22 PM
■ Transmission Distance Specifications for Data Carriers with Large
Memory Capacity (Built-in-battery/Battery-less/Replaceable-battery)
Recommended combinations
Data Carrier
V600-D8KR12
Installation
R/W Head
V600-H07
Stationary
Moving
V600-H11
Stationary
Moving
V600-D8KR13
V600-H07
Stationary
Controller
mode
V600-H11
Stationary
Condition for DC and R/W head
installation
Flush-mount- Irrelevant
ed in metal
10 to 50 mm (max. axial offset ±10 mm)
R/W Head
Surfacemounted on
metal
10 to 60 mm (max. axial offset ±10 mm)
Metal
Flush-mounted in metal
25 to 50 mm (max. axial offset ±10 mm)
Surfacemounted on
metal
25 to 60 mm (max. axial offset ±10 mm)
Flush-mount- Irrelevant
ed in metal
5 to 40 mm (max. axial
offset ±10 mm)
Surfacemounted on
metal
5 to 45 mm (max. axial
offset ±10 mm)
Flush-mounted in metal
25 to 40 mm (max. axial offset ±10 mm)
Surfacemounted on
metal
25 to 45 mm (max. axi- The listed transmission distances
al offset ±10 mm)
also apply for installation on nonmetallic surfaces. Refer to the V600
10 to 30 mm (max. axi- R/W Heads and SRAM Data Carriers Operation Manual (Cat. No.
al offset ±10 mm)
10 to 35 mm (max. axi- Z127) for details.
Data Carrier
Surface-mounted on metal
Metal
Flush-mount- Irrelevant
ed in metal
Surfacemounted on
metal
Moving
Transmission
distance
Data Carrier
Flush-mounted in metal
Metal
al offset ±10 mm)
Flush-mounted in metal
20 to 30 mm (max. axial offset ±10 mm)
Surfacemounted on
metal
20 to 35 mm (max. axial offset ±10 mm)
Flush-mount- Irrelevant
ed in metal
10 to 30 mm (max. axial offset ±10 mm)
Surfacemounted on
metal
Moving
Flush-mounted in metal
15 to 30 mm (max. axial offset ±10 mm)
Surfacemounted on
metal
Electromagnetic Coupling RFID System V600
15
Q124-E1-03.fm Page 16 Tuesday, May 30, 2006 5:22 PM
Recommended combinations
Data Carrier
V600-D8KR04
(unsealed)
Installation
R/W Head
V600-H07
Stationary
Moving
V600-H11
Stationary
Moving
V600-D8KF04
V600-H07
Stationary
Moving
V600-H11
Stationary
Moving
V600-D2KR16
V600-H11
Stationary
Moving
Controller
mode
Flush-mount- Irrelevant
ed in metal
See note1.
Surfacemounted on
metal
10 to 100 mm (max.
axial offset ±10 mm)
Flush-mounted in metal
See note1.
Surfacemounted on
metal
50 to 100 mm (max.
axial offset ±10 mm)
Flush-mount- Irrelevant
ed in metal
See note1.
Surfacemounted on
metal
10 to 65 mm (max. axial offset ±10 mm)
Flush-mounted in metal
See note1.
Surfacemounted on
metal
30 to 65 mm (max. axial offset ±10 mm)
Flush-mount- Irrelevant
ed in metal
See note1.
Surfacemounted on
metal
10 to 50 mm (max. axial offset ±10 mm)
Flush-mounted in metal
See note1.
Surfacemounted on
metal
25 to 50 mm (max. axial offset ±10 mm)
Flush-mount- Irrelevant
ed in metal
See note1.
Surfacemounted on
metal
10 to 32 mm (max. axial offset ±10 mm)
Flush-mounted in metal
See note1.
Surfacemounted on
metal
15 to 32 mm (max. axial offset ±10 mm)
Flush-mount- Irrelevant
ed in metal
2 to 15 mm (max. axial
offset ±10 mm) (See
note 2.)
Surfacemounted on
metal
2 to 15 mm (max. axial
offset ±10 mm)
Flush-mounted in metal
6 to 15 mm (max. axial
offset ±10 mm) (See
note 2.)
Surfacemounted on
metal
10 to 15 mm (max. axial offset ±10 mm)
Note: 1. When Data Carriers are flush-mounted in metal, the read/
write distance will depend on the distance (x) between the
side of the DC and the metal surface.
Refer to the V600 R/W
Heads and SRAM Data
Carriers Operation Manual
(Cat. No. Z127) for details.
16
mm
Flush-mounted
Transmission
distance
mm
20 mm max.
Metal
Electromagnetic Coupling RFID System V600
Condition for DC and R/W head
installation
The listed transmission distances
also apply for installation on nonmetallic surfaces. Refer to the V600
R/W Heads and SRAM Data Carriers Operation Manual (Cat. No.
Z127) for details.
2. Use the following method for flush mounting into a metallic
base.
10 mm min.
10 mm min.
Flush-mounted
Metal
Q124-E1-03.fm Page 17 Tuesday, May 30, 2006 5:22 PM
■ Influence of Surrounding Metal
V600-D8KR04 Combined with V600-H07
V600-D8KR04 Combined with V600-H11
(Axial offset: ±0 mm)
(Axial offset: ±0 mm)
Transmission distance (mm)
Transmission distance (mm)
100
100
R/W Head
50
80
60
40
R/W Head
Data Carrier
Data Carrier
20
0
∞
40
60
80
(Above 100)
Distance from metal surface ( ) (mm)
20
V600-D8KF04 Combined with V600-H07
0
50
40
30
R/W Head
50
40
30
R/W Head
Data Carrier
10
10
40
60
80
100
(Above 100)
Distance from metal surface ( ) (mm)
∞
60
20
20
80
(Axial offset: ±0 mm)
70
20
0
60
V600-D8KF04 Combined with V600-H11
Transmission distance (mm)
Transmission distance (mm)
60
40
(Above 100)
Distance from metal surface ( ) (mm)
(Axial offset: ±0 mm)
70
20
0
20
Data Carrier
40
60
80
100
(Above 100)
Distance from metal surface ( ) (mm)
Electromagnetic Coupling RFID System V600
17
Q124-E1-03.fm Page 18 Tuesday, May 30, 2006 5:22 PM
Lower-level Communications Mode Setting (Distance/Time Priority)
The lower-level communications mode is set with the DIP Switch or memory switch on the Serial-interface Controller (V600-CA5D02, V600-CD1DV3, V600-CM1D) or ID Sensor Unit. (Refer to the Controller’s operation manual for more details on the setting.)
Characteristic Data (Typical)
■ Transmission Range
Note: The values shown in the following graphs are in millimeters. Refer to pages 10 to 16 for details on Data Carrier and R/W Head mounting
conditions.
Battery-less Data Carriers with Small Memory Capacity
V600-D23P71 & V600-H07
V600-D23P71 & V600-H11
Y
Y
Y
Y
80
100
80
60
X
X
60
40
40
20
20
–120 –100 –80 –60 –40 –20
0
20
40
60
–100 –80
80 100 120 X
V600-D23P72 & V600-H07
–60
–40
–20
0
20
40
60
100 X
80
V600-D23P72 & V600-H11
Y
Y
Y
Y
60
100
80
X
X
40
60
40
20
20
–120 –100 –80 –60 –40 –20
0
20
40
60
80 100 120 X
–80
V600-D23P66N & V600-H07
–60
–40
–20
0
20
40
60
80 X
V600-D23P66N & V600-H11
Y
Y
Y
Y
60
80
X
60
X
40
40
20
20
–100 –80
–60
–40
–20
0
20
40
60
80
–80
100 X
V600-D23P66SP & V600-H07
–60
–40
–20
0
20
40
60
80 X
V600-D23P66SP & V600-H11
Y
Y
Y
Y
60
80
60
X
X
40
40
20
20
–100 –80
–60
–40
–20
0
20
40
60
80
–80
100 X
V600-D23P61 & V600-H11
–60
–40
–20
0
20
40
60
80 X
V600-D23P61 & V600-H51
Y
Y
Y
Y
30
40
X
X
30
20
20
10
10
–50
–40
–30
–20
–10
0
10
20
30
40
Read range (in transmission distance priority mode)
18
–40
50 X
–30
–20
–10
0
10
20
Write range (in transmission distance or transmission time priority mode)
Read range (in transmission time priority mode)
Electromagnetic Coupling RFID System V600
30
40 X
Q124-E1-03.fm Page 19 Tuesday, May 30, 2006 5:22 PM
V600-D23P53 & V600-HS51
+V600-HA51
V600-D23P53 & V600-HS61
+V600-HA51
Y
V600-D23P53 & V600-H52
Y
Y
Y
Y
X
X
–5
0
5
–10
10 X
V600-D23P54 & V600-HS51
+V600-HA51
5
–5
0
5
Y
5
5
5
10
Y
15
X
–15
–10
–5
0
5
10
15
X
V600-D23P55 & V600-HS61
+V600-HA51
Y
Y
15
–5
X
10
5
Y
X
10
0
–15
–10
–5
0
X
Y
X
X
10
5
5
5
15
15
15
10
10
10
Y
Y
10
5
5
V600-D23P55 & V600-H52
15
X
0
10 X
15
10
–5
5
Y
15
V600-D23P55 & V600-HS51
+V600-HA51
–10
0
Y
X
–15
–5
V600-D23P54 & V600-H52
Y
15
–10
–10
10 X
V600-D23P54 & V600-HS61
+V600-HA51
Y
–15
X
5
5
–10
Y
10
10
10
X
Read range (in transmission distance priority mode)
–15
–10
–5
0
5
10
15
X
–15
–10
–5
0
5
10
15
X
Write range (in transmission distance or transmission time priority mode)
Read range (in transmission time priority mode)
Electromagnetic Coupling RFID System V600
19
Q124-E1-03.fm Page 20 Tuesday, May 30, 2006 5:22 PM
Built-in-battery Data Carriers with Large Memory Capacity
V600-D8KR12 & V600-H07
V600-D8KR12 & V600-H11
Y
Y
Y
Y
80
60
X
X
60
40
40
20
20
–100 –80
–60
–40
–20
0
20
40
60
100 X
80
V600-D8KR13 & V600-H07
–80
–60
–40
–20
0
20
40
60
80 X
V600-D8KR13 & V600-H11
Y
Y
Y
Y
80
60
X
X
60
40
40
20
20
–100 –80
–60
–40
–20
0
20
40
60
80
100 X
V600-D8KR04 & V600-H07
–80
–60
–40
–20
0
20
40
60
80 X
V600-D8KR04 & V600-H11
Y
Y
Y
Y
80
120
X
X
60
80
40
40
–160
–120
–80
–40
20
0
40
80
120
160 X
–100 –80
–60
–40
–20
0
20
40
60
80
100 X
Battery-less Data Carriers with Large Memory Capacity
V600-D8KF04 & V600-H07
V600-D8KF04 & V600-H11
Y
Y
Y
80
X
60
−100 −80
−60
−40
Y
80
40
40
20
20
−20
0
20
40
60
80
X
60
100 X
−100 −80
−60
−40
−20
0
20
Replaceable-battery Data Carriers with Large Memory Capacity
V600-D2KR16 & V600-H11
Y
Y
60
X
40
20
–80
–60
–40
–20
0
20
40
60
80 X
Read/Write range (in transmission distance or transmission time priority mode)
20
Electromagnetic Coupling RFID System V600
40
60
80
100 X
Q124-E1-03.fm Page 21 Tuesday, May 30, 2006 5:22 PM
■ Communications Time
• The lower-level communications time does not include the host
communications; it is the time required for communications
between the R/W Head and Data Carrier. The lower-level communications time is used in the equation for the DC speed.
DC Speed = (Distance travelled in the transmission range)/
(Lower-level communications time)
• The communications time does not depend on the model of R/W
Head or Data Carrier, although communications times differ
between Data Carriers with and without batteries.
• The turn around time (TAT) is the total time required from the issuance of a command from the host device (for example, a host computer) until the reception of a response.
RDH1……………*
Command
RD001122……………*
Lower-level communications time
Response
TAT (Turn Around Time)
1,000
800
(Auto) Write
600
400
200
Lower-level Communications Time with
Battery-less Data Carriers (Reference)
(Battery-less Models Excluding V600D8KF04)
Lower-level communication time (ms)
Lower-level communication time (ms)
Lower-level Communications Time with
Built-in-battery Data Carriers (Reference)
(Auto) Read
0
2,500
Transmission distance priority mode
Transmission time priority mode
2,000
(Auto) Write
1,500
1,000
(Auto) Read
500
1
50
100
150
200
250
300
Number of bytes
Calculation (Reference)
0
Lower-level communications time
(ms)
READ
t = 1.8 N + 48.4
WRITE
t = 4.2 N + 86.5
100
150
V600-D8KF04 (Battery-less)
1,000
200
250
300
Number of bytes
Calculation (Reference)
R/W
N is the number of processing bytes.
Lower-level communication time (ms)
50
Lower-level communications
time (ms)
Distance
priority mode
READ
t = 4.3 N + 64.6
WRITE
t = 8.7 N + 167.1
Time priority
mode
READ
t = 1.8 N + 79.0
WRITE
t = 7.1 N + 180.4
N is the number of processing bytes.
800
600
(Auto)Write
400
200
(Auto)Read
0
1
50
100
150
200
250
300
Number of bytes
Calculation (Reference)
Lower-level communications time
(ms)
READ
t = 1.8 N + 168.4
WRITE
t = 4.2 N + 206.5
N is the number of processing bytes.
Electromagnetic Coupling RFID System V600
21
Q124-E1-03.fm Page 22 Tuesday, May 30, 2006 5:22 PM
■ Battery Life
The Data Carrier has a built-in lithium battery.
The following graphs show the relationship between the number of bytes per transmission, the number of transmissions per day, and the battery life.
5 years
8 years
5 years
8 years
Number of bytes/transmission
Number of bytes/transmission
V600-D8KR13 (Typical Example)
Daily number of transmissions x 100
V600-D8KR04 (Typical Example)
Daily number of transmissions x 100
Daily number of transmissions x 100
V600-D8KR12 (Typical Example)
5 years
8 years
Number of bytes/transmission
■ Temperature and Battery Life
V600-D2KR16
The battery life is two years at 25°C regardless of the relationship between the number of bytes read/written and the number of transmissions.
Battery life (years)
Examples Showing Relationship between Battery Life and Temperature
The following table shows the standard values.
2.5
2
1.5
1
Battery consumption rate in one year
20°C
1%
30°C
2%
40°C
4%
50°C
8%
60°C
16%
70°C
32%
Note: If the battery is stored at 70°C and is not installed, the battery
life is calculated as follows:
2 (years) × (1 - 0.32) = 1.36 years
0.5
0
Temperature
10
20
30
40
50
Ambient temperature (˚C)
If the battery is stored at 25°C after one year’s storage, the battery life will be approximately 1 year and 4 months. (The battery
life will be shortened if the battery is used at temperatures close
to 0°C or 50°C.)
The values in the above graph are based on the battery being installed (i.e., the insulation sheet is removed). If the battery is not installed, the
values shown in the above table will apply.
22
Electromagnetic Coupling RFID System V600
Q124-E1-03.fm Page 23 Tuesday, May 30, 2006 5:22 PM
Precautions
Data Carrier Batteries
Built-in-battery Data Carriers
Replaceable-battery Data Carriers
WARNING
The SRAM-type Data Carrier has a built-in lithium
battery which may occasionally ignite, explode, and
burn if mishandled. Do not disassemble, deform,
heat above 212°F (100°C), or incinerate the Data
Carrier.
WARNING
The SRAM-type Data Carrier has replaceable lithium
batteries which may occasionally take fire, explode,
burn, or leak liquid if mishandled. Do not deform,
heat above 212°F (100°C), incinerate, or charge the
batteries, or short-circuit their positive and negative
terminals.
■ Mutual Interference (Reference Values)
Mutual Interference between R/W Heads
When more than one set of R/W Heads are used, mutual interference between the Heads can be avoided by mounting the Heads at the specified
distance as shown below.
V600-H07
V600-H11
• Facing
RD/WT command: 650 mm min.
Auto command: 900 mm min.
• Facing
RD/WT command: 200 mm min.
Auto command: 200 mm min.
650 mm min.
(900 mm min.)
• Side-by-side
RD/WT command: 550 mm min.
Auto command: 1,200 mm min.
200 mm min.
• Side-by-side
RD/WT command: 200 mm min.
Auto command: 200 mm min.
200 mm min.
550 mm min.
(1,200 mm min.)
Electromagnetic Coupling RFID System V600
23
Q124-E1-03.fm Page 24 Tuesday, May 30, 2006 5:22 PM
V600-H51
V600-H52
V600-HS51
• Facing: 120 mm min.
• Facing: 80 mm min.
• Facing: 80 mm min.
V600-H51
V600-H51
V600-H52
V600-HS51
V600-H52
V600-HS51
80 mm min.
80 mm min.
120 mm min.
• Side-by-side: 80 mm min.
• Side-by-side: 100 mm min.
• Side-by-side: 80 mm min.
80 mm min.
80 mm min.
100 mm min.
V600-HS51
V600-H51
V600-H51
V600-H52
V600-HS51
V600-H52
V600-HS61
• Facing: 80 mm min.
• Side-by-side: 80 mm min.
V600-HS61
V600
-HS61
V600-HS61
V600
-HS61
80 mm min.
80 mm min.
Note: If the two R/W Heads are not transmitting simultaneously (i.e., independent read/write), mutual interference will not occur. Therefore, the
restriction on the distance between the Heads will not be applicable.
The commands will be received by the R/W Heads and transmission will oscillate between them.
Mutual Interference between Proximity Sensors
The V600-series Units use electromagnetic coupling (frequency: 530 kHz). When a V600 Unit is wired close to R/W Heads, Proximity Switches,
and Sensors that have an oscillating frequency between 400 and 600 kHz, the Proximity Sensor may malfunction, so be sure to install the Units
according to the distance restrictions specified in the following diagrams. Make sure to thoroughly test that the mounting positions and the fixed
positions of the Sensors are correct before putting them into actual operation.
V600-H07
• Facing: 300 mm min.
• Vertical/Parallel: 400 mm min.
300 mm min.
Proximity Sensor
Proximity Sensor
400 mm min.
400 mm min.
Proximity Sensor
24
V600-H07
Electromagnetic Coupling RFID System V600
V600-H07
Q124-E1-03.fm Page 25 Tuesday, May 30, 2006 5:22 PM
V600-H11
• Facing: 100 mm min.
• Vertical/Parallel: 100 mm min.
100 mm min.
V600-H11
Proximity Sensor
Proximity Sensor
100 mm min.
100 mm min.
V600-H11
Proximity Sensor
V600-H51/H52
V600-HS51
V600-HS61
100 mm min.
V600-HS61
Proximity Sensor
Proximity Sensor
Proximity Sensor
100 mm min.
100 mm min.
Proximity Sensor
V600-H51/52
Proximity Sensor
Proximity Sensor
V600-HS51
200 mm min.
200 mm min.
100 mm min.
150 mm min.
150 mm min.
100 mm min.
Proximity Sensor
Proximity Sensor
V600-HS61
Proximity Sensor
Electromagnetic Coupling RFID System V600
25
Q124-E1-03.fm Page 26 Tuesday, May 30, 2006 5:22 PM
Mutual Interference between Data Carriers
When more than one Data Carrier is used, mutual interference between the DCs can be avoided by making sure that they are mounted apart at
the distances specified below.
Reading/Writing
V600-D23P53
V600-D23P54
R/W Head: V600-H52, V600-HS51 + V600-HA51, V600-HS61 +
V600-HA51
R/W Head: V600-H52, V600-HS51 + V600-HA51, V600-HS61 +
V600-HA51
40 mm min.
45 mm min.
V600-D23P55
V600-D23P61
R/W Head: V600-H52, V600-HS51 + V600-HA51, V600-HS61 +
V600-HA51
R/W Head: V600-H11/-H51
50 mm min.
90 mm min.
V600-D23P66N
V600-D23P66SP
R/W Head: V600-H11
R/W Head: V600-H11
140 mm min.
140 mm min.
R/W Head: V600-H07
R/W Head: 600-H07
160 mm min.
160 mm min.
V600-D23P72
R/W Head: V600-H11
R/W Head: V600-H07
170 mm min.
210 mm min.
140 mm min.
180 mm min.
V600-D23P71
R/W Head: V600-H07
290 mm min.
210 mm min.
26
Electromagnetic Coupling RFID System V600
Q124-E1-03.fm Page 27 Tuesday, May 30, 2006 5:22 PM
V600-D8KR12
R/W Head: V600-H11
R/W Head: V600-H07
140 mm min.
160 mm min.
140 mm min.
160 mm min.
V600-D8KR13
R/W Head: V600-H11
R/W Head: V600-H07
160 mm min.
180 mm min.
160 mm min.
160 mm min.
V600-D8KR04/V600-D8KF04
R/W Head: V600-H11
180 mm min.
R/W Head: V600-H07
220 mm min.
180 mm min.
V600-D2KR16
R/W Head: V600-H11
150 mm min.
90 mm min.
Electromagnetic Coupling RFID System V600
27
Q124-E1-03.fm Page 28 Tuesday, May 30, 2006 5:22 PM
Dimensions
Note: All units are in millimeters unless otherwise indicated.
Data Carriers with Large Memory Capacity
Built-in-battery DCs
V600-D8KR12
V600-D8KR13
65
86
55±0.2
5
27
10
27
Two, 4.5-dia. mounting holes
Two, 4.5-dia. mounting holes
10
10
10
54 44±0.2
40 30±0.2
15
Case: ABS resin
Filler: Epoxy resin
8
V600-D8KR04
86
31
5
5
76±0.2
Four, 4.5-dia. mounting holes
54 44±0.2
20
Case: ABS resin
Filler: Epoxy resin
10
Replaceable-battery DCs
V600-D2KR16
4-R1.5
65
40
R0.5
Case: ABS resin
5
Battery-less DCs
V600-D8KF04
86
31
5
76±0.2
5
Four, 4.5-dia. mounting holes
54 44±0.2
20
28
10
Case: ABS resin
Filler: Epoxy resin
Electromagnetic Coupling RFID System V600
5
10.3 5
76±0.2
Case: ABS resin
Filler: Epoxy resin
Q124-E1-03.fm Page 29 Tuesday, May 30, 2006 5:22 PM
Data Carriers with Small Memory Capacity
Battery-less DCs
V600-D23P53
V600-D23P54
V600-D23P55
V600-D23P61
36
8
12 – 00.2 dia.
R0.2
0
dia.
– 0.1
30±0.1
24
R0.3
R0.2
0
8– 0.1
dia.
24
2-R1.0
5
0
– 0.1
5
6
Case: ABS resin
Filler: Epoxy resin
0
– 0.2
6
Case: ABS resin
Filler: Epoxy resin
Case: PPS resin
Filler: Epoxy resin
V600-D23P66N
2.2
Case: ABS resin
Filler: Epoxy resin
V600-D23P66SP
Mounting Hole Dimensions
4-R4
Two, 3.5-dia. mounting holes
0
– 0.1
25±0.2
4-R3
4-R6
Two, 5.5-dia.
mounting holes
34
2-M3
Mounting Hole Dimensions
2-M5
36.5 34
34
25±0.2
32
80±0.2
25±0.2
Two, 3.5-dia.
Two, 6-dia.
32
3.5±0.1
25±0.2
34
Coating: PFA resin
6.5
1.3
80±0.2
2.5 max.
Case: PPS resin
V600-D23P71
95
V600-D23P72
4-R2
4-R2
50
86
34
54
Case: Glass epoxy resin
Coating: Polyurethane resin
1.5
Case: Glass epoxy resin
Coating: Polyurethane resin
1.5
Electromagnetic Coupling RFID System V600
29
Q124-E1-03.fm Page 30 Tuesday, May 30, 2006 5:22 PM
R/W Heads
V600-H07
Four, 4.5-dia.
mounting holes
100
90±0.2
5
5
50
50
Power indicator
(green)
25
43
100
90±0.2
14.7 dia.
Transmission
indicators
(orange)
Vinyl-insulated
round cord
(6-mm dia.)
Bushing
Connector
10
14
Case: ABS resin
Filler: Epoxy resin
Cable: PVC (oil-resistant)
10
30
20
11
V600-H11
4-R1
2-R5
Vinyl-insulated round cord (6-mm dia.)
Two, 4.5-dia. mounting holes
Bushing
Connector
Accessories: Two brackets
for rear panel mounting
10
40
28
14.7 dia.
43
5
5
27
53
Power (green)/transmission
(orange) indicators
6
Case: ABS resin
Filler: Epoxy resin
Cable: PVC (oil-resistant)
5 13
20
18
23
11
V600-H51
V600-H52
80
(72)
(66)
62.5
85
(77)
(71)
67.5
7
12
43
14.7 dia.
19.8 dia.
43
14.7 dia.
12 dia.
Connector
Connector
Vinyl-insulated round cord (6-mm dia.)
M22X1
Power (green)/transmission (orange) indicators
2 lock washers
M22X1
2 lock washers
2 lock nuts
Vinyl-insulated round cord (6-mm dia.)
2 lock nuts
Power (green)/transmission (orange) indicators
Case: Brass
Transmission window: ABS resin
Filler: Epoxy resin
Cable: PVC (oil-resistant)
V600-HS51 (Sensor Section)
2 lock washers
2 lock nuts
M12X1
V600-HS61 (Sensor Section)
Vinyl-insulated round cord
(4-mm dia.)
Connector
9.6 dia.
13.7 dia.
7
49.5
33
35
30
Case: Brass
Transmission window: ABS resin
Filler: Epoxy resin
Cable: PVC (oil-resistant)
Case: Brass
Transmission window: ABS resin
Filler: Epoxy resin
Cable: PVC (oil-resistant)
Electromagnetic Coupling RFID System V600
30.5
18
4.5
8.5 12±0.1
49.5
18
13.7 dia.
Connector
Transmission surface
10
Two, 3.5x5
mounting holes
6.5
Vinyl-insulated round cord
(4-mm dia.)
Case: ABS resin
Filler: Epoxy resin
Cable: PVC (oil-resistant)
Q124-E1-03.fm Page 31 Tuesday, May 30, 2006 5:22 PM
V600-HA51 (Amplifier Section)
Operating indicator (orange)
Power indicator (green)
12.8 dia.
22.6 22
51.7
5.9
61.8
5
(10,000)
43
Connector
13.7 dia.
14.7 dia.
36.5
23.5
8
4
Two, 4.5-dia. mounting holes
13.2
51.3±0.2
35.6
6.1
Vinyl-insulated round cord Connector
6-mm dia (7/0.18-mm dia.),
8-conductor cable
Case: ABS resin
Filler: Epoxy resin
Cable: PVC (oil-resistant)
ID Controllers
V600-CA5D02 (Compact)
Two, 4.5-dia.
mounting holes
80
105
5
95
65
18
90
80
17.5
5
7.5
V600-CD1D-V3 (Compact)
18
OPEN
53
68
17.5
5.5
50
81
92
80
Two, 4.5-dia.
115
V600-CM1D (Board-mounted)
102
92
5
6
16.5
78
76
9
21.5
57.4
95 86.3
107
Four, 3.5-dia.
R/W Head connector
Electromagnetic Coupling RFID System V600
31
Q124-E1-03.fm Page 32 Tuesday, May 30, 2006 5:22 PM
■ Accessories
Holder
V600-A81
68
40±0.1
8-R0.5
20 24±0.1 42
(Four, 3.5-dia.)
(Four, 5.5-dia.)
Case: ABS resin
9
3.5
2-R2.5
V600-A84
Use M3 countersunk screws in the two 3.2-dia.
mounting holes or apply ultrasonic welding.
99.8±0.5
8.5
4-R3
42.5
24.4
5
2.1
67.8±0.5
63.6
2.1
2.1
95.6
2.1
Attachment
V600-A86
Material: PPS resin
4-R5.5
37
34
25±0.2
Two, 4-dia.
15
16
25±0.2
15
4
3.5
34
10
37
Mounting Hole Dimensions
2-M3
25±0.2
25±0.2
ALL DIMENSIONS SHOWN ARE IN MILLIMETERS.
To convert millimeters into inches, multiply by 0.03937. To convert grams into ounces, multiply by 0.03527.
32
Electromagnetic Coupling RFID System V600
Q124-E1-03.fm Page 36 Tuesday, May 30, 2006 5:22 PM
READ AND UNDERSTAND THIS DOCUMENT
Please read and understand this document before using the products. Please consult your OMRON representative if you have any questions or comments.
WARRANTY
OMRON’s exclusive warranty is that the products are free from defects in materials and workmanship for a period of one year (or other period if specified) from date of
sale by OMRON.
OMRON MAKES NO WARRANTY OR REPRESENTATION, EXPRESS OR IMPLIED, REGARDING NON-INFRINGEMENT, MERCHANTABILITY, OR FITNESS
FOR PARTICULAR PURPOSE OF THE PRODUCTS. ANY BUYER OR USER ACKNOWLEDGES THAT THE BUYER OR USER ALONE HAS DETERMINED THAT
THE PRODUCTS WILL SUITABLY MEET THE REQUIREMENTS OF THEIR INTENDED USE. OMRON DISCLAIMS ALL OTHER WARRANTIES, EXPRESS OR
IMPLIED.
LIMITATIONS OF LIABILITY
OMRON SHALL NOT BE RESPONSIBLE FOR SPECIAL, INDIRECT, OR CONSEQUENTIAL DAMAGES, LOSS OF PROFITS OR COMMERCIAL LOSS IN ANY
WAY CONNECTED WITH THE PRODUCTS, WHETHER SUCH CLAIM IS BASED ON CONTRACT, WARRANTY, NEGLIGENCE, OR STRICT LIABILITY.
In no event shall responsibility of OMRON for any act exceed the individual price of the product on which liability is asserted.
IN NO EVENT SHALL OMRON BE RESPONSIBLE FOR WARRANTY, REPAIR, OR OTHER CLAIMS REGARDING THE PRODUCTS UNLESS OMRON’S
ANALYSIS CONFIRMS THAT THE PRODUCTS WERE PROPERLY HANDLED, STORED, INSTALLED, AND MAINTAINED AND NOT SUBJECT TO
CONTAMINATION, ABUSE, MISUSE, OR INAPPROPRIATE MODIFICATION OR REPAIR.
SUITABILITY FOR USE
THE PRODUCTS CONTAINED IN THIS DOCUMENT ARE NOT SAFETY RATED. THEY ARE NOT DESIGNED OR RATED FOR ENSURING SAFETY OF
PERSONS, AND SHOULD NOT BE RELIED UPON AS A SAFETY COMPONENT OR PROTECTIVE DEVICE FOR SUCH PURPOSES. Please refer to separate
catalogs for OMRON's safety rated products.
OMRON shall not be responsible for conformity with any standards, codes, or regulations that apply to the combination of products in the customer’s application or use
of the product.
At the customer’s request, OMRON will provide applicable third party certification documents identifying ratings and limitations of use that apply to the products. This
information by itself is not sufficient for a complete determination of the suitability of the products in combination with the end product, machine, system, or other
application or use.
The following are some examples of applications for which particular attention must be given. This is not intended to be an exhaustive list of all possible uses of the
products, nor is it intended to imply that the uses listed may be suitable for the products:
• Outdoor use, uses involving potential chemical contamination or electrical interference, or conditions or uses not described in this document.
• Nuclear energy control systems, combustion systems, railroad systems, aviation systems, medical equipment, amusement machines, vehicles, safety equipment,
and installations subject to separate industry or government regulations.
• Systems, machines, and equipment that could present a risk to life or property.
Please know and observe all prohibitions of use applicable to the products.
NEVER USE THE PRODUCTS FOR AN APPLICATION INVOLVING SERIOUS RISK TO LIFE OR PROPERTY WITHOUT ENSURING THAT THE SYSTEM AS A
WHOLE HAS BEEN DESIGNED TO ADDRESS THE RISKS, AND THAT THE OMRON PRODUCT IS PROPERLY RATED AND INSTALLED FOR THE INTENDED
USE WITHIN THE OVERALL EQUIPMENT OR SYSTEM.
PERFORMANCE DATA
Performance data given in this document is provided as a guide for the user in determining suitability and does not constitute a warranty. It may represent the result of
OMRON’s test conditions, and the users must correlate it to actual application requirements. Actual performance is subject to the OMRON Warranty and Limitations of
Liability.
CHANGE IN SPECIFICATIONS
Product specifications and accessories may be changed at any time based on improvements and other reasons.
It is our practice to change model numbers when published ratings or features are changed, or when significant construction changes are made. However, some
specifications of the product may be changed without any notice. When in doubt, special model numbers may be assigned to fix or establish key specifications for your
application on your request. Please consult with your OMRON representative at any time to confirm actual specifications of purchased products.
DIMENSIONS AND WEIGHTS
Dimensions and weights are nominal and are not to be used for manufacturing purposes, even when tolerances are shown.
ERRORS AND OMISSIONS
The information in this document has been carefully checked and is believed to be accurate; however, no responsibility is assumed for clerical, typographical, or
proofreading errors, or omissions.
PROGRAMMABLE PRODUCTS
OMRON shall not be responsible for the user’s programming of a programmable product, or any consequence thereof.
COPYRIGHT AND COPY PERMISSION
This document shall not be copied for sales or promotions without permission.
This document is protected by copyright and is intended solely for use in conjunction with the product. Please notify us before copying or reproducing this document in
any manner, for any other purpose. If copying or transmitting this document to another, please copy or transmit it in its entirety.
Cat. No. Q124-E1-03
OMRON Corporation
2007. 3
In the interest of product improvement, specifications are subject to change without notice.
Industrial Automation Company
http://www.ia.omron.com/