RFID System (Conforms to SEMI standard, Electromagnetic Inductive 134 kHz)
V640 Series
CSM_V640_Series_DS_E_10_4
Line-up Ethernet I/F model newly. RFID
system for Semiconductor applications,
supports reading and writing TI (Texas
Instruments) transponders
■ Conforms to RFID wireless interface standards (ISO/IEC
18000-2)
■ Supports SEMI standards (E4, E5, E99, E15.1, E144-0312)
■ Supports SECS commands (when using V700-L22-V2)
■ Embedded Web browser function provides easy
configuration and read/write testing (Ethernet type only)
■ Enhanced functions, TEST Mode / Detecting for CIDRW Head status
■ Certified as radio by many countries: the USA’s FCC, EU
R&TTE directive, Canada’s IC, China, South Korea,
Taiwan, Singapore, and Israel.
Note: Update of radio certifications can be confirmed in the OMRON website.
http://www.ia.omron.com/index.html
Be sure to read the “Safety Precautions” on page 6
System Configuration
Standard Models
CID Tag
CIDRW Head
CIDRW Amplifier Unit
RS-232C/RS-485
CIDRW Controller
RI-TRP-DR2B(-30)
RI-TRP-WR2B(-30)
RI-TRP-IR2B(-30)
RI-TRP-RR2B(-30)
*
Texas
Instruments
HOST
original command
RS-232C
SECS I/II
protocol
PC
V640-HAM11-V4
CIDRW Amplifier Unit
V700-L22-V2
V640-HS61
Ethernet
TCP/IP original command
PLC
V640-HAM11-ETN-V2
Long-range Communications Model
CID Tag
CIDRW Head
CIDRW Amplifier Unit
RS-232C/RS-485
HOST
original command
CIDRW Controller
RS-232C
SECS I/II
protocol
RI-TRP-DR2B(-30)
RI-TRP-WR2B(-30)
*
Texas
Instruments
V640-HAM11-L-V2
PC
CIDRW Amplifier Unit
V700-L22-V2
V640-HS62
Ethernet
TCP/IP original command
V640-HAM11-L-ETN-V2
PLC
Note: 1. Use of the V700-L11 ID Link Unit enables the CIDRW Amplifier Unit to be removed/installed while the CIDRW System remains turned
ON in the event of a malfunction or during maintenance.
2. Use the V700-L22-V2 CIDRW Controller when using SECS communications protocol.
3. For details,refer to the User's Manual.Confirm the Manual No. that is listed in Related Manuals.
* Communication performance does not guarantee.
1
V640 Series
Ordering Information
List of Models
Name
Appearance
Size
Specifications
Model
50 × 30 × 12 mm
(including mounting
plate)
Standard Models
2-meter cable
V640-HS61 2M
65 × 30 × 12 mm
(including mounting
plate)
Long-range
Communications Model
1.9-meter cable
V640-HS62 1.9M
80 × 185 × 43 mm
RS-232C interface
RS-485 interface
24 VDC
V640-HAM11-V4
80 × 185 × 43 mm
Ethernet interface
24 VDC
V640-HAM11-ETN-V2
80 × 185 × 43 mm
RS-232C interface
RS-485 interface
24 VDC
V640-HAM11-L-V2
80 × 185 × 43 mm
Ethernet interface
24 VDC
V640-HAM11-L-ETN-V2
CIDRW Controller
150 × 167 × 28 mm
24 VDC
RS-232C interface
(Compatible with
SECS I/II protocol.)
V700-L22-V2
ID Link Unit
110 × 65 × 64 mm
24 VDC
RS-232C interface
RS-485 interface
V700-L11
Connector accessories
for the V640 CIDRW
Amplifier Unit
Power Supply Connector (1)
Power Supply Connector Pins (3) ✽
RS-485 Port Connector (1)
CIDRW Head
CIDRW Amplifier Unit
V640-A90
* V640-A90 includes all of these accessories as a set. To purchase individual accessories, contact the manufacturers below directly.
Purchasing Individual Accessories
Name
Power Supply Connector
Model
1-178288-3
Power Supply Connector Pins 175217-3
RS-485 Port Connector
MSTB2.5/2-STF-5.08
Manufacturer
Tyco Electronics
Phoenix Contact Inc.
2
V640 Series
Specifications and Ratings
CIDRW Head
Model
V640-HS61
V640-HS62
Item
Transmission frequency
134 kHz
Insulation resistance
20 MΩ min. (at 100 VDC) between the connector terminals and the case
Dielectric strength
1,000 VAC (50/60 Hz, 1 minute) between the connector terminals and the case (leakage current: 5 mA
max.)
Vibration resistance
10 to 150 Hz, 0.20-mm double amplitude, 15-m/s2 acceleration with 10 sweeps of 8 min each in X, Y, and
Z directions
Shock resistance
150-m/s2 acceleration for 3 times each in X, Y, and Z directions (18 times in total)
Ambient operating temperature
0 to 40°C (with no icing)
Ambient operating humidity
35% to 85% (with no condensation)
Ambient storage temperature
−15 to 65°C (with no icing)
Ambient storage humidity
35% to 85% (with no condensation)
Degree of protection
IEC60529: IP20
Cable
2-m (3-mm dia.) coaxial cable
Case
ABS/epoxy resin, stainless-steel mounting fixture
Weight
Approx. 70 g
1.9-m (3-mm dia.) coaxial cable
Approx. 100 g
CIDRW Amplifier Unit
Model
V640-HAM11-V4
V640-HAM11-L-V2
V640-HAM11-ETN-V2
V640-HAM11-L-ETN-V2
Item
Host interface
RS-232C/RS-485
Power supply voltage
24 VDC (max. fluctuation 20.4 to 26.4 VDC)
Ethernet (TCP/IP)
Current consumption
150mA or less
Insulation resistance
20 MΩ min. (at 100 VDC) between the power supply terminals and the frame ground terminal
Dielectric strength
1,000 VAC (50/60 Hz, 1 minute) between the power supply terminals and the frame ground terminal
(leakage current: 5 mA max.)
Vibration resistance
10 to 150 Hz, 0.20-mm double amplitude, 15-m/s2 acceleration with 10 sweeps of 8 min each in X, Y, and
Z directions
Shock resistance
150-m/s2 acceleration for 3 times each in X, Y, and Z directions (18 times in total)
Ambient operating temperature
0 to 40°C (with no icing)
Ambient operating humidity
35% to 85% (with no condensation)
Ambient storage temperature
−15 to 65°C (with no icing)
Ambient storage humidity
35% to 85% (with no condensation)
Degree of protection
IEC60529: IP20
Case
ABS+PC
Ground
Ground at a resistance of less than 100 Ω.
Weight
Approx. 250 g
Wireless interface standards
ISO/IEC 18000-2 and SEMI E144-0312
400mA or less
150mA or less
400mA or less
3
V640 Series
CIDRW Controller
Model
V700-L22-V2
Item
Host interface
RS-232C
Power supply voltage
24 VDC (max. fluctuation 20.4 to 26.4 VDC)
Current consumption
150 mA or less
Insulation resistance
50 MΩ min. (at 500 VDC) between the power supply terminals and the frame ground terminal
Dielectric strength
500 VAC (50/60 Hz, 1 minute) between the power supply terminals and the ground terminal
Vibration resistance
10 to 150 Hz, 0.20-mm double amplitude, 15-m/s2 acceleration with 10 sweeps of 8 min each in X, Y, and
Z directions
Shock resistance
150-m/s2 acceleration for 3 times each in X, Y, and Z directions (18 times in total)
Ambient operating temperature
0 to 40°C (with no icing)
Ambient operating humidity
10% to 85% (with no condensation)
Ambient storage temperature
−15 to 65°C (with no icing)
Ambient storage humidity
10% to 95% (with no condensation)
Degree of protection
IEC60529: IP20
Ground
Ground at a resistance of less than 100 Ω.
Case
SECC (coating)
Weight
Approx. 560 g
ID Link Unit
Model
V700-L11
Item
Host interface
RS-232C or RS-485
Power supply voltage
24 VDC (max. fluctuation 20.4 to 26.4 VDC)
Current consumption
250 mA or less
Insulation resistance
50 MΩ min. (at 500 VDC) between the power supply terminals and the frame ground terminal
Dielectric strength
1,000 VAC (50/60 Hz, 1 minute) between the power supply terminals and the frame ground terminal
(leakage current: 5 mA max.)
Vibration resistance
10 to 150 Hz, 0.20-mm double amplitude, 15-m/s2 acceleration with 10 sweeps of 8 min each in X, Y, and
Z directions
Shock resistance
150-m/s2 acceleration for 3 times each in X, Y, and Z directions (18 times in total)
Ambient operating temperature
0 to 40°C (with no icing)
Ambient operating humidity
35% to 85% (with no condensation)
Ambient storage temperature
−15 to 50°C (with no icing)
Ambient storage humidity
35% to 85% (with no condensation)
Degree of protection
IEC60529: IP20
Ground
Ground at a resistance of less than 100 Ω. If grounding is not performed properly, transmission
specifications may be adversely affected by the surrounding environment.
Case
PC/ABS resin
Weight
Approx. 200 g
4
V640 Series
Functional Specifications
Serial Type System Configuration Examples
System Configuration Using CIDRW Controller (V700-L22-V2)
The Carrier ID Reader Writer (CIDRW) System is an RFID system that conforms to SEMI standards. The V700-L22-V2 CIDRW Controller, the
V640-HAM1@ CIDRW Amplifier Unit, the V640-HS6@ CIDRW Head, and a Texas Instruments CID Tag can be used to configure a Carrier ID
Reader Writer (CIDRW) System that conforms to the following standards:
Note: SEMI: Semiconductor Equipment and Materials International
SECS: SEMI Equipment Communications Standard
CIDRW System
CIDRW Controller
V700-L22-V2
Host device
Just the relevant CIDRW Amplifier Unit can be
removed and replaced while the power remains on.
Link Unit
V700-L11
CIDRW Amplifier Unit
V640-HAM11-V4
V640-HAM11-L-V2
RS-232C
SECS I/II
CIDRW Head
V640-HS61
V640-HS62
RS-232C
RS-485
50 m max.
Up to 31 Units can be connected.
Ethernet Type System Configuration Examples
Host device
Ethernet HUB
LAN cable
CIDRW Amplifier Unit
V640-HAM11-ETN-V2
CIDRW Head
V640-HS61
CIDRW Amplifier Unit
V640-HAM11-ETN-V2
CIDRW Head
V640-HS61
CIDRW Amplifier Unit
V640-HAM11-ETN-V2
CIDRW Head
V640-HS61
LAN cable
Host computer,
device controller, etc.
LAN cable
LAN cable
The Amplifier Unit controls the
CIDRW Head.
The CIDRW Head is the
antenna. It reads and writes
carrier IDs and performs
other processing for CID Tags.
Note: If the IP address is set on the DIP switch, it will be in the form 192.168.1.@@@. The subnet mask is always 255.255.255.0.
The IP address of the CIDRW Amplifier Unit can be either set on this DIP switch or the desired IP address can be set in ROM. If pins 1 to 5
on the DIP switch are all turned OFF, the IP address that is set in ROM will be used.
5
V640 Series
Safety Precautions
WARNING
The product is not designed or rated for ensuring safety
of persons.
Do not use it for such purposes.
Precautions for Correct Use
Please observe the following precautions to prevent failure to
operate, malfunctions, or undesirable effects on product
performance.
About installation Site
Precautions for Safe Use
Please observe the following precautions for safe use of the
products.
• Never use the product in an environment where combustible or
explosivegas is present.
• Please separate from a high-pressure equipment and the power
equipment to secure the safety of the operation and maintenance.
• In the installation, please tighten the screw surely. (Recommended
1.2N.m)
• Please do not insert foreign bodies such as water and the wires
from the space of the case.
• Please do not dismantle, repair or modify this product.
• Please process as industrial waste when you abandon this
product.
• When you work on wiring and put on and take off cables, CIDRW
head, please perform it after switching off this product.
• Provide enough space around this product for ventilation.
• Please avoid installing this product near the machinery (a heater,
a transformer, large-capacity resistance) that has high the calorific
value. hen you felt abnormality to this product, and having switched
it off.
Confirm the effects of radio waves on medical devices. The following
guideline is from JAISA (Japan Automatic Identification Systems
Association).
This product is a reader-writer that uses radio waves for RFID equipment.
The application and location of this product may affect medical devices.
The following precaution must be observed in the application of the product
to minimize the effects on medical devices.
Any person with an implanted medical device must keep the area where
the device is implanted at least 22 cm away from the antenna of a
stationary or modular RFID device.
Do not install this product in the locations subject to the
following conditions.
• Place where direct sunshine strikes.
• Place with corroded gas, dust, metallic powder, and salinity.
• Place with condensation due to rapid temperature fluctuations.
• Place with condensation due to high humidity.
• Place where vibration and impact more than being provided by
specification are transmitted directly to main body.
• Place with spray of water, oil, and chemical medicine.
• The working temperature is within the range stipulated in the
specifications.
About depositoty Site
• Please follow the save ambient temperature / humidity, and keep
this product.
About wiring
• Use the power supply voltage specified in this cocument.
• Ensure correct polarity when connecting to the +/- power supply
terminals.
• Do not run high-voltage lines and power lines though the same
conduit.
• To avoid static-induced failure, wear a wrist band or equivalent
means to release a static charge before touching a terminal or a
signal line within a connector.
• In using this product in EU association states, the cable for DC
power supply to this product must not be extended over 3m.
• When you put on and take off a CIDRW head, please do not add
excessive power to a connector.
• Please connect the correct CIDRW head to the CIDRW amplifier
unit.
About cleaning
• Use alcohol to clean this product.
• Never use an organic solvent such as thinner, benzene, acetone
or kerosene, as it will attack resin components or case coating.
Power and Graound Cables
• Use an appropriate ground. An insufficient ground can affect this
product operation or result in damage to this product.
About the communication range and time
• Do the communication test with Transponder in the installation
environment because the metal, noise and ambient temperature
around CIDRW head damage to the communication range and
time.
• Install CIDRW head and CID tag in the appropriate distance
because the communication range can change by the difference of
CID tag specifications.
6
V640 Series
About mounting
• This product communicates with CID Tags using the 134 kHZ
frequency band. Some transceivers, motors, monitoring
equipment, and power supplies (power supply ICs) generate
electrical waves (noise) that interfere with communications with
CID Tags, If you are using the product in the vicinity of any of these
devices, check the effect on communications in advance.
• In order to minimize the effects of noise, ground nearby metal
bodies with a grounding resistance not exceeding 100 ohms.
• When mounting CIDRW Heads, tighten the screws tightly.
(Recommended 0.6N·m)
• When multiple CIDRW Heads are mounted next to each other,
communications performance could be impaired by mutual
interference. Read and follow the information in User's Manual on
mutual interference when installing multiple heads.
Screw Locking Adhesive
• Screw locking adhesive (screw lock) may cause deterioration and
cracking of resin parts; do not use it for screws in resin parts or
anywhere where resin washers are used.
Communications with the Host Device
(V640-HAM11-V4 and V680-HAM11-L-V2 only)
• Communicate with the host device only after confirming that the
CIDRW Controller has started. Also, unstable signals may occur at
the host interface when the CIDRW Controller is started. When
initializing operation, clear the reception buffer at the host device
or take other suitable methods to clear unwanted signals.
Startup Precaution
• Never turn OFF the power supply while the CIDRW Controller is
starting, including when power is turned ON, when the mode is
changed, or when the CIDRW Controller is being reset. Doing so
may damage the CIDRW Controller.
Application Precaution
(V640-HAM11-ETN-V2 and V640-HAM11-L-ETN-V2 only)
• Never turn OFF the power supply while setting the IP address,
subnet mask, or Web password. Doing so may damage the
CIDRW Amplifier Unit.
7
V640 Series
Dimensions
(Unit: mm)
CIDRW Head
V640-HS61
Four, 3.5 dia.
(mounting holes)
Antenna center
9
Mounting Hole Dimensions
Connector
4-M3 or 3.5 dia.
3.0-dia. coaxial cable, standard length 2 m
Antenna center
30 20 12 10
20±0.2
21
29.2
50
9
21±0.2
12
4
CIDRW Head
V640-HS62
Four, 3.5 dia.
(mounting holes)
9
Antenna center
3.0-dia. coaxial cable, length 1.9 m
Connector
Mounting Hole Dimensions
Antenna center
4-M3 or 3.5 dia.
30 20 12 10
21
20±0.2
39.2
Ferrite core
65
35
9
21±0.2
12
14.5
4
28.5
8
V640 Series
CIDRW Amplifier Unit
V640-HAM11-V4
V640-HAM11-L-V2
(30.2)
DC power supply connector
(15.8)
Four operation indicator lamps
(18.2)
55.5
RS-485 connector
(13) (17.75)
(12)
6.8
6.8
6.8
80
(12)
56
0.6
46
(32.5)
(22.5)
160
175
185
RS-232C connector
DIP switch
Four, 4.5 dia. (mounting holes)
(4.2)
(11.5)
(1)
(5.7)
5
43
(32.5)
Mounting Hole Dimensions
175±0.5
46±0.5
4-M4
CIDRW Amplifier Unit
V640-HAM11-ETN-V2
V640-HAM11-L-ETN-V2
DC power supply connector
(15.8)
Four operation indicator lamps
(18.2)
55.5
MAC address label
(13)
(18)
6.8
6.8
6.8
80
(31.95)
46
(22.5)
160
175
185
Ethernet connector
(12)
56
0.6
DIP switch
Four, 4.5 dia. (mounting holes)
(11.5)
(5.7)
5
43
(32.5)
Mounting Hole Dimensions
175±0.5
4-M4
46±0.5
9
V640 Series
CIDRW Controller
V700-L22-V2
150
130
28
Operation
indicator
lamps
Mounting Hole Dimensions
130±0.2
4-M4
151 167
151±0.2
Power lamp
8
Four, 4.5 dia. (mounting holes)
ID Link Unit
V700-L11
110
41.5
26.5
41.3
18.5 20.3
65
Mounting Hole Dimensions
16.7 10.7
35.2
5
4
Two, 4.5 dia.
4
55±0.2
2-M4 or 4.2 dia.
100±0.2
60
10
V640 Series
Related Manuals
English Cat.No.
Japanese Cat.No.
Model
Z360-E1
SDGR-712
V640-HAM11-V4
V640-HAM11-L-V2
V640-HS61/HS62
V700-L11/L22 ✽ /L22-V2
Z361-E1
SDGR-713
V640-HAM11-ETN-V2
V640-HAM11-L-ETN-V2
V640-HS61
V640-HS62
Name
V640 Series User's Manual
V640 Series User's Manual
* Production was discontinued.
11
Terms and Conditions Agreement
Read and understand this catalog.
Please read and understand this catalog before purchasing the products. Please consult your OMRON representative if you
have any questions or comments.
Warranties.
(a) Exclusive Warranty. Omron’s exclusive warranty is that the Products will be free from defects in materials and workmanship
for a period of twelve months from the date of sale by Omron (or such other period expressed in writing by Omron). Omron
disclaims all other warranties, express or implied.
(b) Limitations. OMRON MAKES NO WARRANTY OR REPRESENTATION, EXPRESS OR IMPLIED, ABOUT
NON-INFRINGEMENT, MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE OF THE PRODUCTS. BUYER
ACKNOWLEDGES THAT IT ALONE HAS DETERMINED THAT THE
PRODUCTS WILL SUITABLY MEET THE REQUIREMENTS OF THEIR INTENDED USE.
Omron further disclaims all warranties and responsibility of any type for claims or expenses based on infringement by the
Products or otherwise of any intellectual property right. (c) Buyer Remedy. Omron’s sole obligation hereunder shall be, at
Omron’s election, to (i) replace (in the form originally shipped with Buyer responsible for labor charges for removal or
replacement thereof) the non-complying Product, (ii) repair the non-complying Product, or (iii) repay or credit Buyer an amount
equal to the purchase price of the non-complying Product; provided that in no event shall Omron be responsible for warranty,
repair, indemnity or any other claims or expenses regarding the Products unless Omron’s analysis confirms that the Products
were properly handled, stored, installed and maintained and not subject to contamination, abuse, misuse or inappropriate
modification. Return of any Products by Buyer must be approved in writing by Omron before shipment. Omron Companies shall
not be liable for the suitability or unsuitability or the results from the use of Products in combination with any electrical or
electronic components, circuits, system assemblies or any other materials or substances or environments. Any advice,
recommendations or information given orally or in writing, are not to be construed as an amendment or addition to the above
warranty.
See http://www.omron.com/global/ or contact your Omron representative for published information.
Limitation on Liability; Etc.
OMRON COMPANIES SHALL NOT BE LIABLE FOR SPECIAL, INDIRECT, INCIDENTAL, OR CONSEQUENTIAL DAMAGES,
LOSS OF PROFITS OR PRODUCTION OR COMMERCIAL LOSS IN ANY WAY CONNECTED WITH THE PRODUCTS,
WHETHER SUCH CLAIM IS BASED IN CONTRACT, WARRANTY, NEGLIGENCE OR STRICT LIABILITY.
Further, in no event shall liability of Omron Companies exceed the individual price of the Product on which liability is asserted.
Suitability of Use.
Omron Companies shall not be responsible for conformity with any standards, codes or regulations which apply to the
combination of the Product in the Buyer’s application or use of the Product. At Buyer’s request, Omron will provide applicable
third party certification documents identifying ratings and limitations of use which apply to the Product. This information by itself
is not sufficient for a complete determination of the suitability of the Product in combination with the end product, machine,
system, or other application or use. Buyer shall be solely responsible for determining appropriateness of the particular Product
with respect to Buyer’s application, product or system. Buyer shall take application responsibility in all cases.
NEVER USE THE PRODUCT FOR AN APPLICATION INVOLVING SERIOUS RISK TO LIFE OR PROPERTY OR IN LARGE
QUANTITIES WITHOUT ENSURING THAT THE SYSTEM AS A WHOLE HAS BEEN DESIGNED TO ADDRESS THE RISKS,
AND THAT THE OMRON PRODUCT(S) IS PROPERLY RATED AND INSTALLED FOR THE INTENDED USE WITHIN THE
OVERALL EQUIPMENT OR SYSTEM.
Programmable Products.
Omron Companies shall not be responsible for the user’s programming of a programmable Product, or any consequence
thereof.
Performance Data.
Data presented in Omron Company websites, catalogs and other materials is provided as a guide for the user in determining
suitability and does not constitute a warranty. It may represent the result of Omron’s test conditions, and the user must correlate
it to actual application requirements. Actual performance is subject to the Omron’s Warranty and Limitations of Liability.
Change in Specifications.
Product specifications and accessories may be changed at any time based on improvements and other reasons. It is our
practice to change part numbers when published ratings or features are changed, or when significant construction changes are
made. However, some specifications of the Product may be changed without any notice. When in doubt, special part numbers
may be assigned to fix or establish key specifications for your application. Please consult with your Omron’s representative at
any time to confirm actual specifications of purchased Product.
Errors and Omissions.
Information presented by Omron Companies has been checked and is believed to be accurate; however, no responsibility is
assumed for clerical, typographical or proofreading errors or omissions.
2021.12
In the interest of product improvement, specifications are subject to change without notice.
OMRON Corporation
Industrial Automation Company
http://www.ia.omron.com/