Two-circuit Limit Switch
WL-N/WL
Two-circuit limit switches that can be
selected to match the operating
environment and application
• Wide variety of head shapes, including Roller Lever,
Plunger, Flexible Rod, and Fork Lock Lever Switches.
• You can select the optimum actuator shape for the
workpiece shape and movement from a variety of
actuators.
• In addition to general detection, we also have environment
resistant models for harsh environments, sputter resistant
models for welding processes, and long-life models for
high-frequency use.
For the most recent information on models that have been certified for
safety standards, refer to your OMRON website.
Be sure to read Safety Precautions on page 62 to 67
and Safety Precautions for All Limit Switches.
Features
General-purpose Switches
Features Common
A Wide Range of Models
DPDB Operation
You can select the optimum product for the workpiece shape and
movement from a variety of actuators, including Roller Lever,
Plunger, Flexible Rod, and Fork Lock Lever Switches.
The two-circuit double-break structure ensures circuit braking.
• Basic/Retention type Switches (WL-N)
Environment-resistant Switches
Za
(NO)14
13(NO)
(NC)11
12(NC)
11
14
12
13
Six environment resistant models are available
Airtight Switches, Hermetic Switches, Heat-resistant Switches, Lowtemperature Switches, Corrosion-proof Switches, and Weather-proof
Switches are available.
You can select the model based on the onsite environment.
Load
Load
• High-sensitivity/High-precision Switches (WL)
Spatter-prevention Switches
Za
(NO)4
3(NO)
(NC)1
2(NC)
1
4
2
3
Ideal for Welding Sites
Uses stainless steel and plastic materials that prevent the adhesion
of spatter.
They can be used to reduce problems caused by zinc power
generated during welding.
Long-life Switches
Long-life Models for High-frequency
Applications
A mechanical durability of over 30 million cycles is achieved by
improving slidability and the wear resistance of the head.
Load
Load
Degree of Protection; IP67
Models with Connectors to Reduce Wiring
A neon lamp or LED indicates the operating status. This makes
startup checks and maintenance easy.
Sensor I/O Connector Models to Match Wiring
Specifications
Direct-wire types and pre-wired types are available for easy
replacement of limit switches.
1
WL-N/WL
Product Configuration
Generalpurpose
Standard *1
Operation indicators *1
Operating Characteristic
Roller Lever Actuators
Basic Switches
High-sensitivity Switches
High-precision Switches
WLC@-N
WLG@
WLGCA2
Plunger Actuators
Basic Switches
WLD@-N
WLSD@-N
Flexible Rod Actuators
Basic Switches
WLNJ-@-N
Fork Lock Lever Actuator
Retention type Switches
WLCA32-4@-N
Indicator-equipped
Switches:Neon lamps
Basic Switches
High-sensitivity Switches
High-precision Switches
WLC@-LE-N
WLG@-LE
WLGCA2-LE
Indicator-equipped
Switches: Light emitting
diodes (LED)
Basic Switches
High-sensitivity Switches
High-precision Switches
WLC@-LD-N
WLG@-LD
WLGCA2-LD
Indicator-equipped
Switches: Neon lamps
Basic Switches
WLD@-LE-N
WLSD@-LE-N
Indicator-equipped
Switches: Light emitting
diodes (LED)
Basic Switches
WLD@-LD-N
WLSD@-LD-N
Indicator-equipped
Switches: Neon lamps
Basic Switches
WLNJ-@LE-N
Indicator-equipped
Switches: Light emitting
diodes (LED)
Basic Switches
WLNJ-@LD-N
Indicator-equipped
Switches: Neon lamps
Retention type Switches
WLCA32-4@LE-N
Indicator-equipped
Switches: Light emitting
diodes (LED)
Retention type Switches
WLCA32-4@LD-N
Direct-wired Types
Basic Switches
High-sensitivity Switches
High-precision Switches
WLCA2-LDK@-N
WLG2-LDK@
WLGCA2-LDK@
Pre-wired Types
Basic Switches
WLCA2-@LD-M1@@-N
WLCA2-@LD-D@J-N
High-sensitivity Switches
WLG2-@LD-M1@@
WLG2-@LD-D@J@
High-precision Switches
WLGCA2-@LD-M1@@
WLGCA2-@LD-D@J@
Basic Switches
Basic Switches
WLD28-@LDK@-N
WLD28-@LD-M1@@-N
WLD28-@LD-D@J-N
Roller Lever
Actuators
Plunger
Actuators
Flexible Rod
Actuators
Fork Lock
Lever Actuator
Sensor I/O connectors
Roller Lever
Actuators
Plunger
Actuators
*1. The standard wiring specification is the Screw terminal type.
*2. Wiring specification: Smart-click type is also available.
2
Typical models
Head/Actuator
Direct-wired Types
Pre-wired Types
WL-N/WL
Head/Actuator
Environmentresistant
*1
Airtight seal *4
Hermetic seal *4
Heat-resistant
Low-temperature
Corrosion-proof
Weather-proof
Spatter-prevention *1 *3
Long-life *1 *2 *3
*1.
*2.
*3.
*4.
Operating Characteristic
Typical models
Roller Lever Actuators
Basic Switches
High-sensitivity Switches
High-precision Switches
WLC@-55-N
WLG@-55
WLGCA2-55
Plunger Actuators
Basic Switches
WLD@-55-N, WLSD@-55-N
Flexible Rod Actuators
Basic Switches
WLNJ-@55-N
Roller Lever Actuators
Basic Switches
WLC@-139-N
High-sensitivity Switches
High-precision Switches
WLG@-139
WLGCA2-139
Plunger Actuators
Basic Switches
WLD@-139-N, WLSD@-139-N
Flexible Rod Actuators
Basic Switches
WLNJ-@139-N
Roller Lever Actuators
Basic Switches
High-sensitivity Switches
High-precision Switches
WLC@-TH-N
WLG@-TH
WLGCA2-TH
Plunger Actuators
Basic Switches
WLD@-TH-N, WLSD@-TH-N
Flexible Rod Actuators
Basic Switches
WLNJ-@TH-N
Roller Lever Actuators
Basic Switches
High-sensitivity Switches
High-precision Switches
WLC@-TC-N
WLG@-TC
WLGCA2-TC
Plunger Actuators
Basic Switches
WLD@-TC-N, WLSD@-TC-N
Flexible Rod Actuators
Basic Switches
WLNJ-@TC-N
Roller Lever Actuators
Basic Switches
High-sensitivity Switches
WLC@-RP-N
WLG@-RP
High-precision Switches
WLGCA2-RP
Plunger Actuators
Basic Switches
WLD@-RP-N, WLSD@-RP-N
Flexible Rod Actuators
Basic Switches
WLNJ-@RP-N
Roller Lever Actuators
Basic Switches
High-sensitivity Switches
WLC@-P1-N
WLG@-P1
Roller Lever Actuators
Basic Switches
High-sensitivity Switches
High-precision Switches
WLCA2-@S-N
WLG2-@S
WLGCA2-@S
Plunger Actuators
Basic Switches
WLD28-@S-N
Roller Lever Actuators *4
Basic Switches
High-sensitivity Switches
High-precision Switches
WLMCA2-@-N
WLMG2-@
WLMGCA2-@
The standard wiring specification is the Screw terminal type.
Wiring specification: Direct-wire Connector type is also available. Contact your OMRON sales representative for further information.
Wiring specification: Pre-wired Connector type is also available. Contact your OMRON sales representative for further information.
A type with an operation indicator light is also available. For details, see Ordering Information.
3
WL-N/WL
Selection
WL-N/WL Actuator Types and Selection
Head
Appearance
Classification
Operating
force (OF)
Repeat
accuracy *1
★★★
Roller Lever
Medium
★★ *2
Shock and
vibration
resistance *1
Description
★★★
• Can be used over a wide range, from positioning to
workpiece detection.
• Easy to use because the stroke in the direction of revolution
can be set to an angle from 45° to 90° (varies by model),
and the lever can be set to any angle over 360°.
• High-sensitivity Switches with minimal movement before
activation (example: WLG2) and High-precision Switches
with high repeatability (example: WLGCA2) are available.
Roller Lever
Models
Adjustable
Roller Lever
Adjustable Rod
Lever
Medium
★★
★★
• Adjustable length between dog and lever. (Consideration
must be given to telegraphing.)
• Can be used over a wide range, from positioning to
workpiece detection.
• High-sensitivity Switches with minimal movement before
activation (example: WLG12) are also available.
• Suitable for detection of a dog or workpiece with a large
amount of play. (Consideration must be given to
telegraphing.)
• Also good for detection of irregularly shaped workpieces.
• Lightest activation (WLCL-N) among rotating-type limit
switches.
• Rod length is adjustable.
• High-sensitivity Switches with minimal movement before
activation (example: WLG2) are also available.
Medium
★★
★★
Plunger
Large
★★★
★★★
• High repeatability, good for positioning detection.
• The workpiece movement direction and plunger movement
direction must be matched so that an unbalanced load is not
applied to the plunger.
Roller plunger
Large
★★★
★★★
• A wide range of operation is possible by attaching an
auxiliary actuator to a cam, dog, cylinder, or other part.
• High repeatability, good for positioning detection.
★★★
• The tip of the plunger is made of a steel ball, which can be
operated in any direction with no limitations.
• The ball plunger is convenient when the mounting side is not
aligned with the movement direction of the dog or the Limit
Switch is actuated by two dogs in X and Y directions.
Plunger Models
Ball plunger
Coil spring
Large
Small
★★
★
★
• Operation from any direction over 360° is possible,
excluding the axial direction.
• Lowest activation force of the limit switches. Effective for
detection of non-uniform directions and shapes.
• Large tolerance for workpiece play because the actuator
absorbs movement after activation.
★
• The resin rod minimizes damage to the workpiece.
• Operation from any direction over 360° is possible,
excluding the axial direction.
• Lowest activation force of the limit switches. Effective for
detection of non-uniform directions and shapes.
• Large tolerance for workpiece play because the actuator
absorbs movement after activation.
★
• The steel wire enables easy workpiece length adjustment,
and easy bending is possible.
• Operation from any direction over 360° is possible,
excluding the axial direction.
• Lowest activation force of the limit switches. Effective for
detection of non-uniform directions and shapes.
• Large tolerance for workpiece play because the actuator
absorbs movement after activation.
Flexible rod
Models
Resin rod
Steel wire
Small
Small
★
★
Fork Lock Lever
Models
Fork Lock Lever
Medium
★★
★★★
• Self-rotates when operated to a position of 55°, holds state
at the 90° position.
• Reciprocating motion can be detected with a single dog.
• To allow greater deviation in the roller position, two dogs can
be used.
*1. Indications for repeat accuracy and shock and vibration resistance are as follows: ★: OK, ★★: Good, ★★★: Excellent
*2. The top line shows High-precision Switches. The bottom line shows Basic Switches.
4
WL-N/WL
OMRON will combine the switch, Actuator, and wiring method required to build the ideal switch for your application.
According to Operating Environment
Environment
Models
Key specifications
−10°C
+80°C
Ambient operating temperature
Low-temperature
To increase heat resistance, the rubber material have
been changed.
+40°C
To increase resistance to cold, epichlorhydrin rubber
and other measures are used.
WL@-TH-N
WLG@-TH
Standard model *1
Environment-resistant,
Low-temperature Switches High-sensitivity,
High-precision model *1
WL@-TC-N
WLG@-TC
Environment-resistant,
Heat-resistant Switches
WLM@-N
WLMG@
Outdoors
A rubber material resistant to temperature changes is
used.
Stainless steel is used for the screws.
The roller is made of stainless steel with superior corrosion
resistance.
Environment-resistant,
Weather-proof Switches
Standard model *1
High-sensitivity,
High-precision model *1
WL@-P1-N
WLG@-P1
Chemicals and oil
Corrosion-proof specifications have been used for the
housing, fluorine rubber has been used for rubber
parts, and stainless steel has been used for screws
and nuts (except for the actuator) to increase
resistance to oils, chemicals, and weather.
Environment-resistant,
Standard model *1
Corrosion-proof Switches High-sensitivity,
High-precision model *1
WL@-RP-N
WLG@-RP
Water drops and mist
Uses an airtight built-in switch.
Standard model *1
High-sensitivity,
High-precision model *1
WL@-55-N
WLG@-55
Cables are attached. Uses a general-purpose built-in
switch.
The cover screws, case cover, and conduit opening are
molded from epoxy resin to increase the seal. (The
cover cannot be removed.)
Operating environment
Standard model *1
High-sensitivity,
High-precision model *1
+120°C
+5°C
−40°C
WL@-N
WLG@
Long-life Switches
Water-resistant to IP67.
High-temperature
Standard model
High-sensitivity,
High-precision model
Standard model
High-sensitivity,
High-precision model
General-purpose
Switches
Normal
Constant water
drops and mist
Environment-resistant,
Airtight Switches
Standard model *1*2
Environment-resistant,
Molded-terminal Switches High-sensitivity,
High-precision model *1*2
Cables are attached. Uses an airtight built-in switch.
The case cover and conduit opening are molded from
Standard model *1*2
epoxy resin to increase the seal. (The cover cannot be Environment-resistant,
Molded-terminal Switches High-sensitivity,
removed.)
High-precision model *1*2
The SC connector can be removed, so it is possible to
use flexible conduit for the cable.
Cables are attached. Uses an airtight built-in switch.
Environment-resistant,
Standard model *1*2
The cover screws, case cover, and conduit opening are
Molded-terminal Switches High-sensitivity,
molded from epoxy resin to increase the seal. (The cover
High-precision model *1*2
cannot be removed.)
Constant water
drops or splattering
cutting powder
Cables are attached. Uses an airtight built-in switch.
The cover screws, case cover, and conduit opening are
molded from epoxy resin to increase the seal. (The
cover cannot be removed.)
Two-layer seal on actuator rotation shaft.
-141: The Head section is molded from epoxy resin;
Head direction cannot be changed.
-145: The Head section is molded from epoxy resin;
Head can be in any of 4 directions.
Coolant
Cables are attached. Uses an airtight built-in switch.
The cover screws, case cover, conduit opening, and
head screws are molded from epoxy resin to increase
the seal.
(The cover and head cannot be removed.)
Rubber parts are made from fluorine rubber to
increase resistance to coolant.
Spattering from
welding
To prevent spatter during welding, a heat-resistant
resin is used for the indicator cover and screws and
rollers are all made from stainless steel.
Environment-resistant,
Standard model *1*2
Molded-terminal Switches High-sensitivity,
High-precision model *1*2
Environment-resistant,
Standard model *1*2
Molded-terminal Switches High-sensitivity,
High-precision model *1*2
WL@-139-N
WLG@-139
WL@-RP40-N
WLG@-RP40
WL@-140-N
WLG@-140
WL@-141-N
WLG@-141
WL@-145-N
WLG@-145
Environment-resistant,
Anti-coolant Switches
Standard model *1*2
High-sensitivity,
High-precision model *1*2
WL@-RP60-N
WLG@-RP60
Spatter-prevention
Switches
Standard model
High-sensitivity,
High-precision model
WL@-@S-N
WLG2-@S
WLGCA2-@S
*1. Not all functions can be combined with environment-resistant models.
*2. For details on the hermetic structure, see the hermetic mold specifications on pages 40 and 41.
5
WL-N/WL
According to Application Conditions
Conditions
10 A at 125,250, or 500 VAC
0.8 A at 125 VDC
0.4 A at 250 VDC
Durability
Load
Switching
standard
loads
Key specifications
Switching
microloads
0.1 A at 125 VAC,
resistive load
0.1 A at 30 VDC,
resistive load
Normal
durability
Mechanical: 15 million
operation min.
(10 million operation min. for
high-sensitivity models * or
flexible rod models)
Long-life
Mechanical: 30 million
operation min.
Models
General-purpose Switches
Environment-resistant Switches
Spatter-prevention Switches
Long-life Switches
Basic/Retention type Switches
Basic Switches
Basic Switches
Basic Switches
WL@-@-N
General-purpose Switches
Environment-resistant Switches
Spatter-prevention Switches
Long-life Switches
High-sensitivity/High-precision Switches
High-sensitivity/High-precision Switches
High-sensitivity/High-precision Switches
High-sensitivity/High-precision Switches
WL
WLG@
WLG@-S
WLMG@
General-purpose Switches
Basic/Retention type Switches
WL@-@-N
Applicable to either standard
loads or microloads.
Applicable to either standard
loads or microloads.
General-purpose
Microload Switches
High-sensitivity/High-precision Switches
WL
WL01G@
General-purpose Switches
Spatter-prevention Switches
Basic Switches
Basic Switches
WL@-N
WL@-S-N
General-purpose Switches
Spatter-prevention Switches
High-sensitivity/High-precision Switches
High-sensitivity/High-precision Switches
WL
WLG@
WLG@-S
Long-life Switches
Basic Switches
WLM@-N
Long-life Switches
High-sensitivity/
High-precision Switches
WL
WLMG@
According to Ease of Installation and Maintenance
Operation indicator
Conditions
Daily
inspections
and
maintenance
checks
Screw
tightening
and
installation
Key specifications
Neon lamp
125 to 250 VAC
Switching light-ON between
operating/not operating.
(Switching is not possible for
Switches with Molded Terminals.)
General-purpose,
Indicator-equipped Switches
Basic Switches
High-sensitivity/High-precision Switches
WL@-LE-N
WLG@-LE
Spatter-prevention Switches
Basic Switches
High-sensitivity/High-precision Switches
WL@-LES-N
WLG@-LES
LED
10 to 115 VAC/DC
Switching light-ON between
operating/not operating.
(Switching not possible for
models with molded terminals.)
General-purpose,
Indicator-equipped Switches
Basic Switches
High-sensitivity/High-precision Switches
WL@-LD-N
WLG@-LD
Spatter-prevention Switches
Basic Switches
High-sensitivity/High-precision Switches
WL@-LDS-N
WLG@-LDS
General-purpose Switches
Basic Switches
High-sensitivity/High-precision Switches
Basic Switches
High-sensitivity/High-precision Switches
WL@-N
WLG@
WLM@-N
WLMG@
General-purpose Switches
Basic Switches
High-sensitivity/High-precision Switches
WL@-N
WLG@
General-purpose Switches
Basic Switches
High-sensitivity/High-precision Switches
Basic Switches
High-sensitivity/High-precision Switches
WL@-@LDK13@-N
WLG@-@LDK13@
WLM@-LDK13@-N
WLMG@-@LDK13@
General-purpose Switches
Basic Switches
High-sensitivity/High-precision Switches
WL@-@LDK43@-N
WLG@-@LDK43@
Long-life Switches
Basic Switches
High-sensitivity/High-precision Switches
WLM@-LDK43@-N
WLMG@-@LDK43@
General-purpose Switches
Basic Switches
High-sensitivity/High-precision Switches
Basic Switches
High-sensitivity/High-precision Switches
Basic Switches
High-sensitivity/High-precision Switches
WL@-@LD-M1@J-N
WLG@-@LD-M1@J
WL@-@S-M1@J-1-N
WLG@-@S-M1@J-1
WLM@-LD-M1@J-N
WLMG@-LD-M1@J
Basic Switches
High-sensitivity/High-precision Switches
Basic Switches
High-sensitivity/High-precision Switches
Basic Switches
High-sensitivity/High-precision Switches
WL@-@LD-@GJ-N
WLG@-@LD-@GJ@
WL@-@S-@GJS-N
WLG@-@S-@GJS@
WLM@-LD-@GJ-N
WLMG@-LD-@GJ@
Screw terminals. No ground terminal.
Conduit size: G1/2
Screw terminals. Ground terminal.
Conduit size: 4 sizes
Wiring specification
Direct-wired connector, 2-conductor.
Greatly reduces wiring work.
One-touch
connector
attachment
Connector
attachment
in control
and relay
boxes
6
Models
Direct-wired connector, 4-conductor.
Greatly reduces wiring work.
Pre-wired connector, 2-conductor.
Greatly reduces wiring work.
Smartclick connectors for even
easier maintenance.
Long-life Switches
Long-life Switches
Spatter-prevention Switches
Long-life Switches
General-purpose Switches
Pre-wired connector, 4-conductor.
Greatly reduces wiring work.
Smartclick connectors for even
easier maintenance.
Spatter-prevention Switches
Long-life Switches
WL-N/WL
Application Examples
Detection of Passing Pallets on Production
Lines
Detection of Work Table Origins (X, Y, and Z)
on Machine Tools
Detection of Forward and Reverse Movement
of Hydraulic Cylinders on Molding Machines
Detection of Arm Movement on Welding
Robots
Detection of Car Pallet Positions in Parking
Towers
Detection of Vertical Limits on Conveyor
Systems
7
WL-N/WL
Model Number Structure
Model Number Legend (Not all combinations are possible. Ask your OMRON representative for details.)
General-purpose Switches
Standard Switches
Operation indicator Switches
Basic and Retention type Switches
WL@ - @ @ @ @ -N
(1)
(2) (3) (4) (5)
(1) Actuator and Property Specifications
Code
Code
CA2
Roller lever: R38 mm
Blank
CA2-7
Roller lever: R50 mm
55
CA2-8
Roller lever: R63 mm
CA12
Adjustable roller lever: R25 to 89 mm
CL
Adjustable rod lever: 25 to 140 mm
CAL4
Adjustable rod lever: 350 to 380 mm
CAL5
Rod spring lever
CA2-2
Roller lever: R38 mm
CA12-2
CL-2
CA2-2N
CA12-2N
CL-2N
Adjustable roller lever: R25 to 89 mm
Adjustable rod lever: 25 to 140 mm
Roller lever: R38 mm
Adjustable roller lever: R25 to 89 mm
Adjustable rod lever: 25 to 140 mm
CA32-41
Fork lock lever
CA32-42
Fork lock lever
CA32-43
8
Actuator
(2) Built-in Switch Specifications
Specifications
Standard built-in switch
Airtight built-in switch
(3) Conduit Size, Ground Terminal Specifications
Specifications
Code
Conduit Size
Blank
G1/2
G1
G1/2
G
Pg13.5
Y
TS
None
Provided *
M20
1/2-14NPT
* Models with ground terminals are certified for EN/IEC (CE Marking).
(4) Indicator Specifications
Fork lock lever
Code
D18
Sealed top plunger
Blank
D28
Sealed top-roller plunger
LE
Neon lamp: 125 to 250 VAC
D38
Sealed top-ball plunger
LD
LED (10 to 115 VAC/DC)
D2
Top-roller plunger
SD
Horizontal plunger
SD2
Horizontal-roller plunger
SD3
Horizontal-ball plunger
Code
NJ
Flexible rod: Coil spring
Blank
NJ-30
Flexible rod: Coil spring, multi-wire
NJ-2
Flexible rod: Resin rod
NJ-S2
Flexible rod: Steel wire
Ground terminal
Specifications
No indicator
(5) Lever Specifications
A
Specifications
Standard lever (Allen-head bolt)
Double nut lever
WL-N/WL
Model Number Legend (Not all combinations are possible. Ask your OMRON representative for details.)
General-purpose Switches
Standard Switches
Operation indicator Switches
High-sensitivity and High-precision Switches
WL@ @ - @ @ @ @ @ @ @ @
(1) (2)
(3) (4) (5) (6) (7) (8) (9) (10)
(1) Electrical Rating
Code
Blank
01
Specifications
Standard load
Microload
(2) Actuator and Property Specifications
Code
Actuator
G2
Roller lever: R38 mm High-sensitivity
GCA2
Roller lever: R38 mm High-precision
G12
Adjustable roller lever: R25 to 89 mm High-sensitivity
GL
Adjustable roller lever: 25 to 140 mm High-sensitivity
(3) Built-in Switch Specifications
Code
Blank
55
Specifications
Standard built-in switch
Airtight built-in switch
(4) Conduit Size, Ground Terminal Specifications
Specifications
Code
Conduit Size
Blank
G1/2
G1
G1/2
G
Pg13.5
Y
M20
TS
Ground terminal
None
Provided *
1/2-14NPT
* Models with ground terminals are certified for EN/IEC (CE Marking).
(5) Indicator Type
Code
Blank
Specifications
No indicator
LE
Neon lamp: 125 to 250 VAC
LD
LED (10 to 115 VAC/DC)
(6) Lever Type
Code
Blank
A
Specifications
Standard lever (Allen-head bolt)
Double nut lever
9
WL-N/WL
Model Number Legend (Not all combinations are possible. Ask your OMRON representative for details.)
General-purpose Switches
Sensor I/O Connector Switches
Basic and Retention type Switches
WL@ - @ L D @ -N
(1)
(2) (3) (4)
(1) Actuator and Property Specifications
Code
Actuator
CA2
Roller lever: R38 mm
D28
Sealed top-roller plunger
D2
Top-roller plunger
(2) Built-in Switch Specifications
Code
Blank
55
Specifications
Standard built-in switch
Airtight built-in switch
(3) Indicator Specifications
Code
LD
Specifications
LED (10 to 115 VAC/DC)
(4) Connector Type Wiring Specifications
Specifications
Code
Shape
Voltage *1
Wiring locations
AC
NO only
NO: 3 4
DC
NO only
NO: 3 4
AC
NC+NO
NC: 1 2 , NO: 3 4
K43
DC
NC+NO
NC: 1 2 , NO: 3 4
-M1J
DC
NO only
NO: 3 4
-M1GJ
DC
NO only
NO: 1 4
-M1JB
DC
NC only
NC: 3 2
AC
NC+NO
NC: 1 2 , NO: 3 4
DC
NC+NO
NC: 1 2 , NO: 3 4
DC
NO only
NC: 2 , NO: 3 4
-M1TJ
DC
NO only
NO: 3 4
-M1TGJ
DC
NO only
NO: 1 4
DC
NC only
NC: 3 2
-DTGJ
DC
NC+NO
NC: 1 2 , NO: 3 4
-DTK1EJ
DC
NO only
NC: 2 , NO: 3 4
K13A
K13
K43A
Direct-wire Connector type
Threaded (M12)
Threaded (M12)
-AGJ
-DGJ
-DK1EJ
-M1TJB
Pre-wired Connector type
*3
Smartclick
Connector pin No. *2
*1. DC models are certified for EN/IEC (CE Marking).
*2. Refer to Contact Forms on page 21 for details on connector pin numbers.
*3. The standard cable length is 0.3 m. Contact your OMRON representative for information on other cable lengths.
10
WL-N/WL
Model Number Legend (Not all combinations are possible. Ask your OMRON representative for details.)
General-purpose Switches
Sensor I/O Connector Switches
High-sensitivity and High-precision Switches
WL@ @ - @ L D @ -N
(1) (2)
(3) (4) (5)
(1) Electrical Rating
Code
Blank
01
Specifications
Standard load
Microload
(2) Actuator and Property Specifications
Code
Actuator
G2
Roller lever: R38 mm High-sensitivity
GCA2
Roller lever: R38 mm High-precision
(3) Built-in Switch Specifications
Code
Blank
55
Specifications
Standard built-in switch
Airtight built-in switch
(4) Indicator Specifications
Code
LD
Specifications
LED (10 to 115 VAC/DC)
(5) Connector Type Wiring Specifications
Specifications
Code
Shape
K13A
K13
K43A
Direct-wire Connector type
Voltage *1
Wiring locations
AC
NO only
Connector pin No. *2
DC
NO only
NO: 3 4
AC
NC+NO
NC: 1 2 , NO: 3 4
NO: 3 4
K43
DC
NC+NO
NC: 1 2 , NO: 3 4
-M1J *1
DC
NO only
NO: 3 4
DC
NO only
NO: 1 4
DC
NC only
NC: 3 2
NC: 1 2 , NO: 3 4
Threaded (M12)
-M1GJ *1
-M1JB
-AGJ03
Pre-wired Connector type *3
AC
NC+NO
-DGJ03 *1
DC
NC+NO
NC: 1 2 , NO: 3 4
-DK1EJ03 *1
DC
NO only
NC: 2 , NO: 3 4
*1. DC models are certified for EN/IEC (CE Marking).
*2. Refer to Contact Forms on page 21 for details on connector pin numbers.
*3. The standard cable length is 0.3 m. Contact your OMRON representative for information on other cable lengths.
11
WL-N/WL
Model Number Legend (Not all combinations are possible. Ask your OMRON representative for details.)
Environment-resistant Switches
Basic Switches
WL@ - @ @ @ @ @ @ @ @ -N
(1)
(2) (3) (4) (5) (6) (7) (8) (9)
(1) Actuator and Property Specifications
Code
Actuator
CA2
Roller lever: R38 mm
CA2-7
Roller lever: R50 mm
CA2-8
Roller lever: R63 mm
CA12
Adjustable roller lever: R25 to 89 mm
CL
Adjustable rod lever: 25 to 140 mm
Adjustable rod lever: 350 to 380 mm
CAL5
Rod spring lever
CA2-2
Roller lever: R38 mm
CA12-2
Adjustable roller lever: R25 to 89 mm
CL-2
CA12-2N
CL-2N
140
Airtight built-in switch. Cable is attached.
Molded conduit opening, cover, and cover screws. (The cover
cannot be removed.)
141
Conduit opening, cover, head, cover attachment screw part, airtight built-in switch.
Cable is attached.
Molded head screws. (The cover cannot be removed and the
head direction cannot be changed.)
Two-layer seal on actuator rotation shaft.
145
Airtight built-in switch. Cable is attached.
Molded conduit opening, cover, and cover screws.
(The cover cannot be removed. The head can be mounted in
any of 4 directions.)
Two-layer seal on actuator rotation shaft.
RP40
Airtight built-in switch. Cable is attached.
Molded conduit opening and cover. (The cover cannot be removed.)
SC Connector can be removed, so it is possible to use flexible
conduits for the cable.
RP60
Airtight built-in switch. Cable is attached.
Molded conduit opening, cover, cover screws, and head screws.
(The cover cannot be removed and the head direction cannot
be changed.)
Fluorine rubber is used for all rubber parts.
Adjustable rod lever: 25 to 140 mm
Fork lock lever
CA32-42
Fork lock lever
Fork lock lever
D18
Sealed top plunger
D28
Sealed top-roller plunger
D38
Sealed top-ball plunger
D2
Top-roller plunger
SD
Horizontal plunger
SD2
Horizontal-roller plunger
SD3
Horizontal-ball plunger
NJ
Standard built-in switch. Cable is attached.
Molded conduit opening and cover. (The cover cannot be removed.)
Roller lever: R38 mm
Adjustable roller lever: R25 to 89 mm
Flexible rod: Coil spring
Specifications
No cable molding.
139
Adjustable rod lever: 25 to 140 mm
CA32-41
CA32-43
Code
Blank
CAL4
CA2-2N
(5) Hermetic Specifications
(6) Conduit Size, Ground Terminal Specifications
Specifications
Code
Conduit Size
NJ-30
Flexible rod: Coil spring, multi-wire
NJ-2
Flexible rod: Resin rod
Blank
G1/2
NJ-S2
Flexible rod: Steel wire
G1
G1/2
G
Pg13.5
Y
M20
(2) Environment-resistant Model Specifications
Code
Blank
Specifications
Corrosion-proof
P1
Weather-resistant
Code
55
Specifications
TC
Code
Blank
Specifications
No indicator
LE
Neon lamp: 125 to 250 VAC *3
Airtight built-in switch
LD
LED (10 to 115 VAC/DC) *3
Code
TH
1/2-14NPT
Standard built-in switch
(4) Temperature Specifications
Blank
Provided *2
(7) Indicator Specifications
(3) Built-in Switch Specifications
Blank
None
*2. Models with ground terminals are certified for EN/IEC (CE
Marking).
Standard
RP
TS
Ground terminal
Specifications
*3. Cannot be combined with Corrosion-proof (RP), Weather-proof
(P1), Heat-resistant (TC), or Low-temperature (TC) Switches.
(8) Indicator Wiring Specifications
Standard: -10 to +80°C
Heat-resistant: -5 to +120°C *1
Low-temperature: -40 to +40°C *1
*1. Cannot be combined with Corrosion-proof (RP) or Weather-proof
(P1) Switches.
Code
Specifications
2
NC connection: Light-ON when operating *4
3
NO connection: Light-ON when not operating *4
*4. Always include the indicator wiring specification if you specify a
(5) hermetic structure and an (7) indicator.
(9) Lever Type
Code
Blank
A
12
Specifications
Standard lever (Allen-head bolt)
Double nut lever
WL-N/WL
Model Number Legend (Not all combinations are possible. Ask your OMRON representative for details.)
Environment-resistant Switches
High-sensitivity and High-precision Switches
WL@ @ - @ @ @ @ @ @ @ @
(1) (2)
(3) (4) (5) (6) (7) (8) (9) (10)
(1) Electrical Rating
Code
Blank
01
(6) Hermetic Specification
Specifications
Standard load
Microload
(2) Actuator and Property Specifications
Code
Roller lever: R38 mm High sensitivity
GCA2
Roller lever: R38 mm High-precision
G12
Adjustable roller lever: R25 to 89 mm High sensitivity
GL
Adjustable rod lever: 25 to 140 mm High sensitivity
(3) Environment-resistant Model Specifications
Code
P1
Weather-proof
(4) Built-in Switch Specifications
Code
55
140
Airtight built-in switch. Cable is attached.
Molded conduit opening, cover, and cover screws. (The cover
cannot be removed.)
141
Conduit opening, cover, head, cover attachment screw part, airtight built-in switch.
Cable is attached.
Molded head screws. (The cover cannot be removed and the
head direction cannot be changed.)
Two-layer seal on actuator rotation shaft.
145
Airtight built-in switch. Cable is attached.
Molded conduit opening, cover, and cover screws.
(The cover cannot be removed. The head can be mounted in
any of 4 directions.)
Two-layer seal on actuator rotation shaft.
RP40
Airtight built-in switch. Cable is attached.
Molded conduit opening and cover. (The cover cannot be removed.)
SC Connector can be removed, so it is possible to use flexible
conduits for the cable.
RP60
Airtight built-in switch. Cable is attached.
Molded conduit opening, cover, cover screws, and head screws.
(The cover cannot be removed and the head direction cannot
be changed.)
Fluorine rubber is used for all rubber parts.
Specifications
Corrosion-proof
Blank
Standard built-in switch. Cable is attached.
Molded conduit opening and cover. (The cover cannot be removed.)
Standard
RP
Specifications
No cable molding.
139
Actuator
G2
Blank
Code
Blank
Specifications
Standard built-in switch
Airtight built-in switch
(7) Conduit Size, Ground Terminal Specifications
(5) Temperature Specifications
Code
Specifications
Specifications
Code
Conduit Size
Blank
G1/2
Standard: -10 to +80°C
G1
G1/2
TH
Heat-resistant: -5 to +120°C *1
G
Pg13.5
TC
Low-temperature: -40 to +40°C *1
Y
M20
Blank
*1. Cannot be combined with Corrosion-proof (RP) or Weather-proof
(P1) Switches.
TS
Ground terminal
None
Provided *2
1/2-14NPT
*2. Models with ground terminals are certified for EN/IEC (CE
Marking).
(8) Indicator Type
Code
Blank
Specifications
No indicator
LE
Neon lamp: 125 to 250 VAC *3
LD
LED (10 to 115 VAC/DC) *3
*3. Cannot be combined with Corrosion-proof (RP), Weather-proof
(P1), Heat-resistant (TC), or Low-temperature (TC) Switches.
(9) Indicator Wiring Specification
Code
Specifications
2
NC connection: Light-ON when operating *4
3
NO connection: Light-ON when not operating *4
*4. Always include the indicator wiring specification if you specify a
(6) hermetic structure and an (8) indicator.
(10) Lever Type
Code
Blank
A
Specifications
Standard lever (Allen-head bolt)
Double nut lever
13
WL-N/WL
Model Number Legend (Not all combinations are possible. Ask your OMRON representative for details.)
Spatter-prevention Switches
Basic Switches
WL@ - @ @ S@ -N
(1)
(2) (3)
(4)
(1) Actuator and Property Specifications
Code
(3) Indicator Specifications
Actuator
Code
Specifications
CA2
Roller lever: R38 mm
LE
Neon lamp: 125 to 250 VAC *1
D28
Sealed top-roller plunger
LD
LED (10 to 115 VAC/DC)
*1. Cannot be combined with a (4) Connector Type Wiring
Specifications.
(2) Built-in Switch Specifications
Code
Blank
55
Specifications
Standard built-in switch
Airtight built-in switch
(4) Connector Type Wiring Specifications
Specifications
Code
Blank
Shape
Screw terminal type
-M1J-1
-M1GJ-1
-DGJS
Pre-wired Connector type
*4
-DTGJS
Threaded (M12)
Smartclick
Voltage *2
Wiring locations
---
---
Connector pin No. *3
DC
NO only
NO: 3 4
NO: 1 4
---
DC
NO only
DC
NC+NO
NC: 1 2 , NO: 3 4
DC
NC+NO
NC: 1 2 , NO: 3 4
*2. DC models are certified for EN/IEC (CE Marking).
*3. Refer to Contact Forms on page 21 for details on connector pin numbers.
*4. The standard cable length is 0.3 m. Contact your OMRON representative for information on other cable lengths.
Spatter-prevention Switches
High-sensitivity and High-precision Switches
WL@ @ - @ @ S@
(1) (2)
(3) (4)
(5)
(1) Electrical Rating
Code
Blank
01
(3) Built-in Switch Specifications
Specifications
Code
Standard load
Blank
Microload
55
(2) Actuator and Property Specifications
Code
Specifications
Standard built-in switch
Airtight built-in switch
(4) Indicator Specifications
Actuator
Code
Specifications
Blank
Roller lever: R38 High-sensitivity
LE
Neon lamp: 125 to 250 VAC *1
GCA2
Roller lever: R38 High-precision
LD
LED (10 to 115 VAC/DC)
*1. Cannot be combined with a (5) Connector Type Wiring
Specifications.
(5) Connector Type Wiring Specifications
Specifications
Code
Blank
Shape
Screw terminal type
-M1J -1
-M1GJ -1
-DGJS03
Pre-wired Connector type
*4
Threaded (M12)
Voltage *2
Wiring locations
---
---
Connector pin No. *3
DC
NO only
NO: 3 4
DC
NO only
NO: 1 4
DC
NC+NO
NC: 1 2 , NO: 3 4
---
*2. DC models are certified for EN/IEC (CE Marking).
*3. Refer to Contact Forms on page 21 for details on connector pin numbers.
*4. The standard cable length is 0.3 m. Contact your OMRON representative for information on other cable lengths.
14
WL-N/WL
Model Number Legend (Not all combinations are possible. Ask your OMRON representative for details.)
Basic Switches
Long-life Switches
WLM@ - LD@ -N
(1)
(2) (3)
(1) Actuator and Property Specifications
Code
Actuator
CA2
Roller lever: R38 mm
(2) Indicator Type
Code
Specifications
LD
LED (10 to 115 VAC/DC)
(3) Connector Type Wiring Specifications
Specifications
Code
Shape
Blank
Screw terminal type
K13A
K13
Direct-wire Connector type
K43A
Threaded (M12)
Voltage
Wiring locations
---
---
Connector pin No. *1
AC
NO only
DC
NO only
NO: 3 4
AC
NC+NO
NC: 1 2 , NO: 3 4
--NO: 3 4
K43
DC
NC+NO
NC: 1 2 , NO: 3 4
-M1J
DC
NO only
NO: 3 4
NC: 1 2 , NO: 3 4
-AGJ
Threaded (M12)
-DGJ
Pre-wired Connector type *2
-M1TJ
Smartclick
-DTGJ
AC
NC+NO
DC
NC+NO
NC: 1 2 , NO: 3 4
DC
NO only
NO: 3 4
DC
NC+NO
NC: 1 2 , NO: 3 4
*1. Refer to Contact Forms on page 21 for details on connector pin numbers.
*2. The standard cable length is 0.3 m. Contact your OMRON representative for information on other cable lengths.
High-sensitivity and High-precision Switches
Long-life Switches
WLM@ - LD@
(1)
(2) (3)
(1) Actuator and Property Specifications
Code
Actuator
G2
Roller lever: R38 mm High-sensitivity
GCA2
Roller lever: R38 mm High-precision
(2) Indicator Type
Code
LD
Specifications
LED (10 to 115 VAC/DC)
(3) Connector Type Wiring Specifications
Specifications
Code
Blank
Shape
Voltage
Screw terminal type
K13A
K13
K43A
Direct-wire Connector type
K43
Threaded (M12)
-M1J
-AGJ03
-DGJ03
Pre-wired Connector type *2
Wiring locations
Connector pin No. *1
---
---
AC
NO only
---
DC
NO only
NO: 3 4
AC
NC+NO
NC: 1 2 , NO: 3 4
NC: 1 2 , NO: 3 4
NO: 3 4
DC
NC+NO
DC
NO only
NO: 3 4
AC
NC+NO
NC: 1 2 , NO: 3 4
DC
NC+NO
NC: 1 2 , NO: 3 4
*1. Refer to Contact Forms on page 21 for details on connector pin numbers.
*2. The standard cable length is 0.3 m. Contact your OMRON representative for information on other cable lengths.
15
WL-N/WL
Ordering Information
General-purpose Switches
Standard Switches
Switches with Roller Lever Actuators
Basic Switches
Actuator
Roller lever: R38
Pretravel (PT)
Roller lever: R50
Model
Roller lever: R63
Model
WLCA2-N
25±5°
WLCA2-2-N
---
---
20° max.
WLCA2-2N-N
---
---
Actuator
WLCA2-7-N
Model
15±5°
Adjustable rod lever:
25 to 140 mm
Adjustable roller lever
Pretravel (PT)
Model
WLCA2-8-N
Adjustable rod lever:
350 to 380 mm
Model
Rod spring lever
Model
WLCAL4-N
Model
15±5°
WLCA12-N
WLCL-N
WLCAL5-N
25±5°
WLCA12-2-N
WLCL-2-N
---
---
20° max.
WLCA12-2N-N
WLCL-2N-N
---
---
High-sensitivity Switches
Actuator
Roller lever: R38
Load
Adjustable roller lever
Model
Adjustable rod lever:
25 to 140 mm
Model
Model
Standard load
WLG2
WLG12
WLGL
Microload
WL01G2
WL01G12
WL01GL
High-precision Switches
Actuator
Roller lever: R38
Load
Model
Standard load
WLGCA2
Microload
WL01GCA2
Switches with Plunger Actuators
Basic Switches
Actuator
Pretravel (PT)
1.7 mm max.
Sealed Top-roller
plunger
Sealed Top Plunger
Model
Model
WLD18-N
Actuator
Horizontal plunger
Pretravel (PT)
2.8 mm max.
WLD28-N
Horizontal-roller plunger
Model
Model
WLSD-N
WLSD2-N
Sealed Top-ball plunger
Top-roller plunger
Model
WLD38-N
Model
WLD2-N
Horizontal-ball plunger
Model
WLSD3-N
Switches with Flexible Rod Actuators
Basic Switches
Actuator
Coil spring
(spring diameter: 6.5)
Pretravel (PT)
20±10 mm
Coil spring
(spring diameter: 4.8)
Model
Model
WLNJ-N
Actuator
WLNJ-30-N
Resin rod
(rod diameter: 8)
Pretravel (PT)
40±20 mm
Steel wire
(wire diameter: 1)
Model
WLNJ-2-N
WLNJ-S2-N
Switches with Fork Lock Lever Actuator
Retention type Switches
Actuator
Pretravel (PT)
55° max.
16
Fork lock lever
Model
WLCA32-41-N
Fork lock lever
Model
WLCA32-42-N
Fork lock lever
Model
WLCA32-43-N
Fork lock lever
Model
WLCA32-44-N
WL-N/WL
General-purpose Switches
Operation indicator Switches
Switches with Roller Lever Actuators
Basic Switches
Actuator
Roller lever: R38
Indicator *
Neon lamp
LED
Pretravel (PT)
Model
WLCA2-LE-N
25±5°
WLCA2-2LE-N
---
20° max.
WLCA2-2NLE-N
---
15±5°
WLCA2-LD-N
WLCA2-7LD-N
Model
WLCA2-8LE-N
----WLCA2-8LD-N
WLCA2-2LD-N
---
---
20° max.
WLCA2-2NLD-N
---
---
Pretravel (PT)
15±5°
LED
WLCA2-7LE-N
Roller lever: R63
25±5°
Adjustable roller lever
Neon lamp
Model
15±5°
Actuator
Indicator *
Roller lever: R50
Adjustable rod lever:
25 to 140 mm
Model
Model
Adjustable rod lever:
350 to 380 mm
Rod Spring Lever
Model
Model
WLCAL4-LE-N
WLCAL5-LE-N
WLCA12-LE-N
WLCL-LE-N
25±5°
WLCA12-2LE-N
WLCL-2LE-N
---
20° max.
WLCA12-2NLE-N
WLCL-2NLE-N
---
15±5°
WLCA12-LD-N
WLCL-LD-N
25±5°
WLCA12-2LD-N
WLCL-2LD-N
---
---
20° max.
WLCA12-2NLD-N
WLCL-2NLD-N
---
---
WLCAL4-LD-N
----WLCAL5-LD-N
High-sensitivity Switches
Actuator
Roller lever R38
Indicator *
Neon lamp
LED
Pretravel (PT)
10° +2°
-1°
Model
WLG2-LE
WLG2-LD
Actuator
Adjustable roller lever
Indicator *
Neon lamp
LED
Pretravel (PT)
10°
+2°
-1°
Adjustable rod lever:
25 to 140 mm
Model
Model
WLG12-LE
WLGL-LE
WLG12-LD
WLGL-LD
High-precision Switches
Actuator
Roller lever R38
Indicator *
Neon lamp
LED
Pretravel (PT)
5°
+2°
0°
Model
WLGCA2-LE
WLGCA2-LD
Switches with Fork Lock Lever Actuator
Retention type Switches
Actuator
Fork lock lever
Indicator *
Neon lamp
LED
Pretravel (PT)
55° max.
Model
WLCA32-41LE-N
WLCA32-41LD-N
Fork lock lever
Model
WLCA32-42LE-N
---
Fork lock lever
Model
WLCA32-43LE-N
WLCA32-43LD-N
* The default setting is light-ON when not operating (NO wiring). Turn the lamp holder by 180° to change the setting to light-ON when operating
(NC wiring).
17
WL-N/WL
Switches with Plunger Actuators
Basic Switches
Actuator
Indicator *
Neon lamp
LED
Pretravel (PT)
1.7 mm max.
Actuator
Indicator *
Neon lamp
LED
Pretravel (PT)
2.8 mm max.
Sealed Top plunger
Sealed Top-roller
plunger
Model
Model
Sealed Top-ball
plunger
Model
Top-roller plunger
Model
WLD18-LE-N
WLD28-LE-N
WLD38-LE-N
WLD2-LE-N
WLD18-LD-N
WLD28-LD-N
WLD38-LD-N
WLD2-LD-N
Horizontal plunger
Horizontal-roller plunger
Model
Model
Horizontal-ball plunger
Model
WLSD-LE-N
WLSD2-LE-N
WLSD3-LE-N
WLSD-LD-N
WLSD2-LD-N
WLSD3-LD-N
Switches with Flexible Rod Actuators
Basic Switches
Actuator
Indicator *
Neon lamp
LED
Pretravel (PT)
20±10 mm
Actuator
Indicator *
Neon lamp
LED
Pretravel (PT)
40±20 mm
Coil spring
(spring diameter: 6.5)
Model
Coil spring
(spring diameter: 8)
Model
WLNJ-LE-N
WLNJ-30LE-N
WLNJ-LD-N
WLNJ-30LD-N
Resin rod
(rod diameter: 8)
Model
Steel wire
(wire diameter: 1)
Model
WLNJ-2LE-N
WLNJ-S2LE-N
WLNJ-2LD-N
WLNJ-S2LD-N
* The default setting is light-ON when not operating (NO wiring). Turn the lamp holder by 180° to change the setting to light-ON when operating
(NC wiring).
18
WL-N/WL
General-purpose Switches
Sensor I/O Connector Switches
Switches with Direct-wired Connectors
Basic Switches
Actuator
Sealed Top-roller
plunger
Roller lever: R38
Connector
shape
Built-in switch
specification
Voltage
Wiring
Specifications
Generalpurpose
Threaded
DC
Airtight
DC
Pretravel (PT)
Model
Model
2 core
NO 3 4
WLCA2-LDK13A-N
---
NC + NO 4 core
NC 1 2
NO 3 4
WLCA2-LDK43A-N
---
NO only
2 core
NO 3 4
NC + NO 4 core
NC 1 2
NO 3 4
NO only
2 core
NC + NO 4 core
NO only
AC
Connector pin
No.
WLCA2-LDK13-N
WLD28-LDK13-N
WLCA2-LDK43-N
WLD28-LDK43-N
NO 3 4
WLCA2-55LDK13-N
WLD28-55LDK13-N
NC 1 2
NO 3 4
WLCA2-55LDK43-N
WLD28-55LDK43-N
15±5°
High-sensitivity Switches
Actuator
Roller lever: R38
Connector
shape
Built-in switch
specification
Voltage
DC
Airtight
Connector pin
No.
2 core
NO 3 4
NC + NO 4 core
NC 1 2
NO 3 4
NO only
2 core
NO 3 4
NC + NO 4 core
NC 1 2
NO 3 4
NO only
Generalpurpose
Threaded
Wiring
Specifications
Pretravel (PT)
Model
WLG2-LDK13
WLG2-LDK43
10° +2°
-1°
WLG2-55LDK13
WLG2-55LDK43
High-precision Switches
Actuator
Roller lever: R38
Connector
shape
Built-in switch
specification
Voltage
DC
Airtight
Connector pin
No.
2 core
NO 3 4
NC + NO 4 core
NC 1 2
NO 3 4
NO only
2 core
NO 3 4
NC + NO 4 core
NC 1 2
NO 3 4
NO only
Generalpurpose
Threaded
Wiring
Specifications
Pretravel (PT)
Model
WLGCA2-LDK13
WLGCA2-LDK43
5° +2°0°
WLGCA2-55LDK13
WLGCA2-55LDK43
Note: The default setting is light-ON when not operating (NO wiring).
Turn the lamp holder by 180° to change the setting to light-ON when operating (NC wiring).
(However, Four-core Switches cannot be switched to light-ON when operating (NC wiring).)
19
WL-N/WL
Switches with Pre-wired Connectors
Basic Switches
Actuator
Sealed Top-roller
Plunger
Roller lever: R38
Connector
shape
Built-in switch
specification
Voltage
Generalpurpose
Threaded *
Wiring
Specifications
Connector pin
No.
Pretravel (PT)
Model
Model
NO 3 4
WLCA2-LD-M1J-N
WLD28-LD-M1J-N
NO 1 4
WLCA2-LD-M1GJ-N
WLD28-LD-M1GJ-N
---
NO only
2 core
NC only
2 core
NC 3 2
WLCA2-LD-M1JB-N
NC + NO 4 core
NC 1 2
NO 3 4
WLCA2-LD-DGJ-N
WLD28-LD-DGJ-N
NO only
NO 3 4
NC 2
WLCA2-LD-DK1EJ-N
WLD28-LD-DK1EJ-N
WLCA2-55LD-M1J-N
WLD28-55LD-M1J-N
3 core
DC
NO only
2 core
NC only
NO 3 4
15±5°
NO 1 4
WLCA2-55LD-M1GJ-N
WLD28-55LD-M1GJ-N
2 core
NC 3 2
WLCA2-55LD-M1JB-N
WLD28-55LD-M1JB-N
NC + NO 4 core
NC 1 2
NO 3 4
WLCA2-55LD-DGJ-N
NO only
NO 3 4
NC 2
WLCA2-55LD-DK1EJ-N
Airtight
3 core
--WLD28-55LD-DK1EJ-N
High-sensitivity Switches
Actuator
Roller lever: R38
Connector
shape
Built-in switch
specification
Voltage
DC
Airtight
Connector pin
No.
2 core
NO 3 4
NC + NO 4 core
NC 1 2
NO 3 4
NO only
2 core
NO 3 4
NC + NO 4 core
NC 1 2
NO 3 4
NO only
Generalpurpose
Threaded *
Wiring
Specifications
Pretravel (PT)
Model
WLG2-LDK13
WLG2-LDK43
10° +2°
-1°
WLG2-55LDK13
WLG2-55LDK43
High-precision Switches
Actuator
Roller lever: R38
Connector
shape
Built-in switch
specification
Voltage
DC
Airtight
Connector pin
No.
Pretravel (PT)
Model
2 core
NO 3 4
WLG2-LDK13
NC + NO 4 core
NC 1 2
NO 3 4
WLG2-LDK43
NO only
2 core
NO 3 4
NC + NO 4 core
NC 1 2
NO 3 4
NO only
Generalpurpose
Threaded *
Wiring
Specifications
5° +2°0°
WLG2-55LDK13
WLG2-55LDK43
* The standard cable length for a pre-wired connector is 0.3 m. Contact your OMRON representative for information on other cable lengths.
Note: The default setting is light-ON when not operating (NO wiring).
Turn the lamp holder by 180° to change the setting to light-ON when operating (NC wiring).
(However, Three-core and Four-core Switches cannot be switched to light-ON when operating (NC wiring).)
20
WL-N/WL
Contact Forms
Wiring specification
Screw terminal types
No indicator
Basic Switches
High-sensitivity/
High-precision Switches
Za
14 (NO)
13 (NO)
(NO) 4
12 (NC)
(NC) 1
Za
Operation indicator (Light-ON when Not Operating) Switches
High-sensitivity/
Basic Switches
High-precision Switches
Za
14 (NO)
11 (NC)
Internal
circuits
Internal
circuits
3 (NO)
13 (NO)
(NO) 4
12 (NC)
(NC) 1
Za
3 (NO)
2 (NC)
11 (NC)
2 (NC)
Direct-wire Connector and Pre-wired Connector types
No indicator
Basic
High-sensitivity/High-precision Switches
AC
AC
DC
Za
NO NC
2 core 4 --4 core 4
DC
Za
Za
---
3
4
---
---
3
NO NC
2 core 4 ---
2
3
2 core 4
---
---
1
4 core 4
---
3
2
---
1 2 3 4 indicate the connector
4 core 4
1
2
3
NC NO
1
Za
NO NC
1 2 3 4 indicate the connector
pin number.
NC NO
NC NO
1
NO NC
NC NO
---
3
4
---
---
2
3
2 core 4
---
---
1
---
3
2
---
3 core 4
---
2
3
4 core 4
1
2
3
pin number.
1 2 3 4 indicate the connector
pin number.
3
1 2 3 4 indicate the connector
pin number.
Operation indicator (Light-ON when Not Operating) Switches
Basic
High-sensitivity/High-precision Switches
Internal
circuits
AC
Internal
circuits
DC
Za
NO NC
2 core 4 --4 core 4
Za
NC NO
--- 3
1
Internal
circuits
AC
2
3
2 core
1 2 3 4 indicate the connector
pin number.
4 core
Internal
circuits
DC
Za
Za
NO NC
NC NO
4
---
---
3
2 core 4
---
---
3
4
---
---
4
---
---
1
4 core 4
1
2
3
2 core 4
---
---
1
---
3
2
---
1 2 3 4 indicate the connector
---
3
2
---
4
1
2
3
3 core 4
---
2
3
4 core 4
1
2
3
NO NC
pin number.
1 2 3 4 indicate the connector
pin number.
NC NO
NO NC
NC NO
3
1 2 3 4 indicate the connector
pin number.
Connector Pin Layout Diagram
Basic/High-sensitivity/High-precision Switches
AC
Positioning piece *2
DC
Positioning piece *2
2
2
3
1
4
3
1
4
Note: Leakage current from indicator circuit may cause load malfunction (i.e., the load may remain ON). Make sure that the load operating current
is higher than the leakage current. For countermeasures, refer to technical support on your OMRON website.
*1. Light-ON when not operating means the operation indicator is lit when the actuator is free and is not light when the Switch contacts (NO) close
when the actuator rotates or is pushed down.
*2. The position of the positioning piece is not always the same. If using an L-shaped connector causes problems in application, use a straight
connector.
21
WL-N/WL
Connecting Sensor I/O connector cable (Socket)
Type
Number of cable
cores
AC/DC Type
Cable length
L (m)
2
AC
4
M12 Screw (Straight)
2
DC
4
M12 Smart click type (Straight)
DC
Applicable limit switch
models
Model
2m
XS2F-A421-DB0-F
5m
XS2F-A421-GB0-F
2m
XS2F-A421-D90-F
5m
XS2F-A421-G90-F
2m
XS2F-D421-DD0
5m
XS2F-D421-GD0
2m
XS2F-D421-DA0-F
5m
XS2F-D421-GA0-F
2m
XS2F-D421-D80-F
5m
XS2F-D421-G80-F
2m
XS5F-D421-D80-F
WL@-@K13A-N
WL@-@K43A-N
WL@-@-AGJ-N
WL@-@K13-N
WL@-@-M1J-N
WL@-@-M1GJ@-N
WL@-@K43-N
WL@-@-M1JB-N
WL@-@-DGJ-N
WL@-@-M1TJ-N
WL@-@-M1TJB-N
4
5m
XS5F-D421-G80-F
Dimensions (Unit: mm)
XS2F-@421-@@0-@
XS2F-D421-@D0
L (Cable length)
40.7
6 dia.
14.9 dia.
DC
AC
30
5
50
Wiring Diagram
Two-core model
AC/DC Type
Model
Terminal No.
AC
Four-core model
Wiring Diagram
XS2F-A421-DB0-F
XS2F-A421-GB0-F
Model
Cable color of
core sheath
1
2
3
4
XS2F-A421-D90-F
XS2F-A421-G90-F
Brown
Blue
Terminal No.
XS2F-D421-DD0
XS2F-D421-GD0
Cable color of
core sheath
1
2
3
4
1
2
3
4
Blue
Brown
Terminal No.
XS2F-D421-D80-F
XS2F-D421-G80-F
Cable color of
core sheath
1
2
3
4
Cable color of
core sheath
Brown
White
Blue
Black
Terminal No.
DC
XS2F-D421-DA0-F
XS2F-D421-GA0-F
Wiring Diagram
Brown
Blue
XS5F-D421-@80-F
Wiring Diagram
L (Cable length)
40.7
AC/DC Type
Model
Wiring Diagram
Terminal No.
5
30
50
DC
22
Four-core model
6 dia.
14.9 dia.
XS5F-D421-D80-F
XS5F-D421-G80-F
1
2
3
4
Cable color of
core sheath
Brown
White
Blue
Black
WL-N/WL
Environment-resistant Switches
Switches with Roller Lever Actuators
Basic Switches
Actuator
Roller lever: R38
Built-in switch specification
Adjustable roller lever
Model
WLCA2-55-N
Airtight seal
Molded terminals, -139 models
Model
WLCA12-55-N
WLCA2-255-N
---
WLCA2-2N55-N
---
WLCA2-139-N
WLCA12-139-N
WLCA2-2139-N
---
WLCA2-2N139-N
---
WLCA2-140-N
Molded terminals, -140 models
WLCA12-140-N
--WLCA2-2N140-N
Hermetic
seal *
WLCA2-141-N
Molded terminals, -141 models
----WLCL-139-N
----WLCL-140-N
---
---
---
-----
---
---
--Anti-coolant
Model
WLCL-55-N
WLCA12-141-N
--WLCA2-RP60-N
Adjustable rod lever:
25 to 140 mm
--WLCA12-RP60-N
WLCA2-2RP60-N
---
--WLCL-RP60-N
---
---
---
---
WLCA2-TH-N
WLCA12-TH-N
WLCL-TH-N
WLCA2-2TH-N
WLCA12-2TH-N
WLCL-2TH-N
WLCA2-2NTH-N
WLCA12-2NTH-N
WLCL-2NTH-N
WLCA2-TC-N
WLCA12-TC-N
WLCL-TC-N
WLCA2-2TC-N
WLCA12-2TC-N
WLCL-2TC-N
WLCA2-2NTC-N
WLCA12-2NTC-N
WLCL-2NTC-N
Corrosion-proof
WLCA2-RP-N
WLCA12-RP-N
WLCL-RP-N
Weather-proof
WLCA2-P1-N
WLCA12-P1-N
WLCL-P1-N
Adjustable roller lever
Adjustable rod lever:
25 to 140 mm
Heat-resistant
Low-temperature
* The maximum cable length for a Hermetic Switch is 5 m.
High-sensitivity Switches
Actuator
Roller lever: R38
Built-in switch specification
Model
Model
WLG2-55
Model
---
---
Molded terminals, -139 models
WLG2-139
---
---
Molded terminals, -140 models
WLG2-140
---
---
Molded terminals, -141 models
WLG2-141
---
---
Anti-coolant
WLG2-RP60
---
---
Airtight seal
Hermetic
seal *
Heat-resistant
WLG2-TH
WLG12-TH
WLGL-TH
Low-temperature
WLG2-TC
WLG12-TC
WLGL-TC
Corrosion-proof
WLG2-RP
WLG12-RP
WLGL-RP
Weather-proof
WLG2-P1
WLG12-P1
WLGL-P1
* The maximum cable length for a Hermetic Switch is 5 m.
High-precision Switches
Actuator
Built-in switch specification
Airtight seal
Hermetic
seal *
Roller lever: R38
Model
WLGCA2-55
Molded terminals, -139 models
WLGCA2-139
Molded terminals, -140 models
WLGCA2-140
Molded terminals, -141 models
WLGCA2-141
Anti-coolant
WLGCA2-RP60
Heat-resistant
WLGCA2-TH
Low-temperature
WLGCA2-TC
Corrosion-proof
WLGCA2-RP
Weather-proof
---
* The maximum cable length for a Hermetic Switch is 5 m.
23
WL-N/WL
Switches with Plunger Actuators
Basic Switches
Actuator
Sealed Top-roller
plunger
Built-in switch specification
Model
Airtight seal
Hermetic
seal *
Top-roller plunger
Model
WLD28-55-N
WLD2-55-N
Molded terminals, -139 models
WLD28-139-N
WLD2-139-N
Molded terminals, -140 models
WLD28-140-N
Anti-coolant
WLD28-RP60-N
WLD2-RP60-N
WLD28-TH-N
WLD2-TH-N
Heat-resistant
--WLSD-RP60-N
Built-in switch specification
Hermetic
seal *
WLSD2-140-N
WLSD2-RP60-N
WLSD-TH-N
WLSD2-TH-N
WLSD-TC-N
WLSD2-TC-N
WLD28-RP-N
---
WLSD-RP-N
WLSD2-RP-N
Coil spring
(spring diameter: 6.5)
Model
Resin rod
(rod diameter: 8)
Model
WLNJ-55-N
WLNJ-255-N
Molded terminals, -139 models
WLNJ-139-N
WLNJ-2139-N
Molded terminals, -140 models
WLNJ-140-N
WLNJ-2140-N
Anti-coolant
WLNJ-RP60-N
WLNJ-2RP60-N
Heat-resistant
WLNJ-TH-N
---
Low-temperature
WLNJ-TC-N
---
Corrosion-proof
WLNJ-RP-N
* The maximum cable length for a Hermetic Switch is 5 m.
24
WLSD2-139-N
---
Switches with Flexible Rod Actuators
Basic Switches
Airtight seal
Model
WLSD2-55-N
WLSD-139-N
---
* The maximum cable length for a Hermetic Switch is 5 m.
Actuator
Model
WLSD-55-N
Horizontal-roller
plunger
---
Low-temperature
Corrosion-proof
Horizontal plunger
WLNJ-2RP-N
WL-N/WL
Environment-resistant Switches
Operation indicator Switches
Switches with Roller Lever Actuators
Basic Switches
Actuator
Built-in switch specification
Indicator *
Neon lamp
Airtight seal
LED
Molded terminals,
-139 models
Hermetic
seal
Molded terminals,
-140 models
LED
Anti-coolant
Wiring
Specifications
Roller lever: R38
Adjustable roller lever
Model
NO wiring
WLCA2-55LE-N
NO wiring
WLCA2-255LE-N
NO wiring
WLCA2-2N55LE-N
NO wiring
WLCA2-55LD-N
Model
WLCA12-55LE-N
----WLCA12-55LD-N
Adjustable rod lever:
25 to 140 mm
Model
------WLCL-55LD-N
NO wiring
WLCA2-255LD-N
---
NO wiring
WLCA2-2N55LD-N
---
-----
NC wiring
WLCA2-139LD2-N
---
---
NO wiring
WLCA2-139LD3-N
---
---
NC wiring
WLCA2-2139LD2-N
---
---
NO wiring
WLCA2-2139LD3-N
---
---
NC wiring
WLCA2-141LD2-N
---
---
NO wiring
WLCA2-141LD3-N
---
---
NC wiring
WLCA2-RP60LD2-N
---
---
NO wiring
WLCA2-RP60LD3-N
---
---
NC wiring
WLCA2-2RP60LD2-N
---
---
NO wiring
WLCA2-2RP60LD3-N
---
---
High-sensitivity Switches
Actuator
Built-in switch specification
Airtight seal
Hermetic
seal
Roller lever: R38
Indicator *
Wiring
Specifications
Neon lamp
NO wiring
WLG2-55LE
LED
NO wiring
WLG2-55LD
Model
Molded terminals,
-139 models
NC wiring
---
NO wiring
WLG2-139LD3
Molded terminals,
-140 models
NC wiring
WLG2-140LD2
NO wiring
WLG2-140LD3
LED
Molded terminals,
-141 models
Anti-coolant
NC wiring
WLG2-141LD2
NO wiring
WLG2-141LD3
NC wiring
WLG2-RP60LD2
NO wiring
WLG2-RP60LD3
High-precision Switches
Actuator
Built-in switch specification
Airtight seal
Hermetic
seal
Roller lever: R38
Indicator *
Wiring
Specifications
Neon lamp
NO wiring
WLGCA2-55LE
LED
NO wiring
WLGCA2-55LD
Model
Molded terminals,
-139 models
NC wiring
WLGCA2-139LD2
NO wiring
WLGCA2-139LD3
Molded terminals,
-140 models
NC wiring
WLGCA2-140LD2
NO wiring
WLGCA2-140LD3
LED
Molded terminals,
-141 models
Anti-coolant
NC wiring
NO wiring
--WLGCA2-141LD3
NC wiring
WLGCA2-RP60LD2
NO wiring
WLGCA2-RP60LD3
* The default setting is light-ON when not operating (NO wiring).
Turn the lamp holder by 180° to change the setting to light-ON when operating (NC wiring).
(Note that the lamp holder cannot be replaced on hermetic models.)
25
WL-N/WL
Switches with Plunger Actuators
Basic Switches
Actuator
Internal
switch
Specifications
Airtight seal
Sealed top-roller
plunger
Top-roller plunger
Indicator *
Wiring
Specifications
Neon lamp
NO wiring
WLD28-55LE-N
WLD2-55LE-N
LED
NO wiring
WLD28-55LD-N
WLD2-55LD-N
Model
Model
* The default setting is light-ON when not operating (NO wiring).
Turn the lamp holder by 180° to change the setting to light-ON when operating (NC wiring).
Switches with Flexible Rod Actuators
Basic Switches
Actuator
Internal
switch
Specifications
Airtight seal
Coil spring
(spring diameter: 6.5)
Resin rod
(rod diameter: 8)
Indicator *
Wiring
Specifications
Neon lamp
NO wiring
---
---
LED
NO wiring
WLNJ-55LD-N
WLNJ-255LD-N
Model
Model
* The default setting is light-ON when not operating (NO wiring).
Turn the lamp holder by 180° to change the setting to light-ON when operating (NC wiring).
26
Horizontal plunger
Model
--WLSD-55LD-N
Horizontal-roller
plunger
Model
--WLSD2-55LD-N
WL-N/WL
Spatter-prevention Switches
Basic Switches
Actuator
Roller lever: R38
Sealed Top-roller
plunger
Double nut lever
Indicator *
Allen-head lever
Model
Model
Model
Neon lamp
WLCA2-LEAS-N
WLCA2-LES-N
WLD28-LES-N
LED
WLCA2-LDAS-N
WLCA2-LDS-N
WLD28-LDS-N
High-sensitivity Switches
Actuator
Roller lever: R38
Double nut lever
Indicator *
Allen-head lever
Model
Model
Neon lamp
WLG2-LEAS
WLG2-LES
LED
WLG2-LDAS
WLG2-LDS
High-precision Switches
Actuator
Roller lever: R38
Double nut lever
Indicator *
Model
Allen-head lever
Model
Neon lamp
---
WLGCA2-LES
LED
---
WLGCA2-LDS
* The default setting is light-ON when not operating (NO wiring).
Turn the lamp holder by 180° to change the setting to light-ON when operating (NC wiring).
27
WL-N/WL
Long-life Switches
Basic Switches
Actuator
Indicator
*1
Roller lever
Screw terminal type
AC/DC
Type
Wiring
Specifications
Connectors
pin No.
AC/DC
---
---
AC
Roller lever
Direct-wire Connector
type
LED
Roller lever
Pre-wired Connector
type *2
DC
Model
WLMCA2-LD-N
2-conductor
NO 3 4
WLMCA2-LDK13A-N
4-conductor
NC 1 2
NO 3 4
WLMCA2-LDK43A-N
2-conductor
NO 3 4
WLMCA2-LDK13-N
4-conductor
NC 1 2
NO 3 4
WLMCA2-LDK43-N
2-conductor
NO 3 4
WLMCA2-LD-M1J-N
4-conductor
NC 1 2
NO 3 4
WLMCA2-LD-DGJ-N
DC
*1. The default setting is light-ON when not operating (NO wiring).
Turn the lamp holder by 180° to change the setting to light-ON when operating (NC wiring).
(However, Four-core Switches cannot be switched to light-ON when operating (NC wiring).)
*2. With 0.3-m cable.
High-sensitivity/High-precision Switches
Actuator
Indicator
*1
Roller lever
Screw terminal type
AC/DC
Type
Wiring
Specifications
Connectors
pin No.
AC/DC
---
---
AC
Roller lever
Direct-wire Connector
type
Roller lever
Pre-wired Connector
type *2
LED
DC
High-precision Models
Model
Model
WLMG2-LD
WLMGCA2-LD
2-conductor
NO 3 4
WLMG2-LDK13A
WLMGCA2-LDK13A
4-conductor
NC 1 2
NO 3 4
WLMG2-LDK43A
WLMGCA2-LDK43A
2-conductor
NO 3 4
WLMG2-LDK13
WLMGCA2-LDK13
4-conductor
NC 1 2
NO 3 4
WLMG2-LDK43
WLMGCA2-LDK43
2-conductor
NO 3 4
WLMG2-LD-M1J
WLMGCA2-LD-M1J
4-conductor
NC 1 2
NO 3 4
WLMG2-LD-DGJ03
DC
*1. The default setting is light-ON when not operating (NO wiring).
Turn the lamp holder by 180° to change the setting to light-ON when operating (NC wiring).
(However, Four-core Switches cannot be switched to light-ON when operating (NC wiring).)
*2. With 0.3-m cable.
28
High-sensitivity
---
WL-N/WL
Individual Parts
Switches without Levers, Heads, and Actuators
General-purpose Parts
Operating
characteristics
Actuator
Roller lever
Basic
High-sensitivity
Adjustable roller
lever
Basic
High-sensitivity
Variable rod lever
Basic
High-sensitivity
Fork lock lever
Top plunger
Horizontal plunger
Flexible rod
Basic
Set
Model
Model
Model
WL-1H1100-N
WLCA2-2-N
WLRCA2-2-N
WL-3H1100-N
WLCA2-2N-N
WLRCA2-2N-N
WL-1H1100-N
WLG2
WLRG2
WL-2H1100
WLCA12-N
WLRCA2-N
WL-1H2100-N
WLCA12-2-N
WLRCA2-2-N
WL-3H2100-N
WLCA12-2N-N
WLRCA2-2N-N
WL-1H2100-N
WLG12
WLRG2
WL-2H2100
WLCL-N
WLRCL-N
WL-4H4100-N
WLCL-2-N
WLRCA2-2-N
WL-3H4100-N
WLCL-2N-N
WLRCA2-2N-N
WL-1H4100-N
WLGL
WLRG2
WL-1A100
WL-2A100
WL-4A100
WL-2H4100
WLCA32-41-N
WL-5H5100-N
WL-5A100
WLCA32-42-N
WL-5H5102-N
WL-5A102
WL-5H5104-N
WL-5A104
WLCA32-44-N
WL-5H5104-N
WL-5A104
WLD18-N
WL-7H100-N
---
WL-7H400-N
---
WLD38-N
WL-7H300-N
---
WLSD-N
WL-8H100-N
---
WL-8H200-N
---
WLSD2-N
WLRCA32-N
---
---
WLSD3-N
WL-8H300-N
---
WLNJ-N
WL-9H100-N
---
WLNJ-30-N
Basic
Actuator only *
WLRCA2-N
WLD28-N
Basic
Heads
(with Actuators)
WLCA2-N
WLCA32-43-N
Basic
Switches without
levers
WLNJ-2-N
---
WLNJ-S2-N
WL-9H200-N
---
WL-9H300-N
---
WL-9H400-N
---
* The same Actuators can be used for both WL and WL-N Switches.
Spatter-prevention Parts
Actuator
Lever
Specifications
Allen-head bolt
lever
Item
Basic
High-sensitivity
Roller lever
Double nut lever
Basic
High-sensitivity
Set Model Numbers
Switches without
levers
Heads
(with Actuators)
Actuator only *
Model
Model
Model
WLCA2-LES-N
WLRCA2-LES-N
WLCA2-LDS-N
WLRCA2-LDS-N
WLG2-LDS
WLRG2-LDS
WLCA2-LEAS-N
WLRCA2-LES-N
WLCA2-LDAS-N
WLRCA2-LDS-N
WLG2-LDAS
WLRG2-LDS
---
WL-1A103S
---
WL-1A105S
* The same Actuators can be used for both WL and WL-N Switches.
29
WL-N/WL
Covers with Indicators (See Note.)
General-purpose/Long-life Parts
Basic Parts
Cover
Indicator *2
Neon lamp
LED
Cover only *1
Color
Model
Orange
WL-LE-N *3
Red
WL-LD-N
Yellow
WL-LW-N *3
High-sensitivity/High-precision Parts
Cover
Indicator *2
Cover only *1
Color
Model
Neon lamp
Orange
WL-LE
LED
Red
WL-LD
*1. The Covers are not compatible with Basic Switches (WL-N), or High-sensitivity/High-precision Switches (WL).
*2. The default setting is light-ON when not operating (NO wiring).
Turn the lamp holder by 180° to change the setting to light-ON when operating (NC wiring).
*3. The Color Universal Design structure is certified by an NPO.
Color Universal Design was developed in consideration of
people with various types of color vision to allow information to
Certification conditions: Ambient illumination of 500 lx max. (JIS
be accurately conveyed to as many individuals as possible.
Z 9110)
Spatter-prevention Parts
Basic Parts
Cover
Indicator *
Cover only
Color
Model
Neon lamp
Orange
WL-LES-N
LED
Red
WL-LDS-N
* The default setting is light-ON when not operating (NO wiring).
Turn the lamp holder by 180° to change the setting to light-ON when operating (NC wiring).
30
WL-N/WL
Specifications
General-purpose/Environment-resistant Switches
Ratings
Wiring Specifications
Screw terminal types
Standard-load Switches (excluding micro-load Switches)
Item
Resistive
load
NC
NO
Lamp
load
NC
NO
Inductive load (A)
Inductive
load
NC
NO
NC
NO
5
3
1.5
2.5
1.5
0.8
AC 125
250
500
10
10
10
3
2
1.5
1.5
1
0.8
10
10
3
Basic
DC
10
10
6
0.8
0.4
6
6
4
0.2
0.1
3
3
3
0.2
0.1
10
10
6
0.8
0.4
Highsensitivity
Highprecision *1
AC 125
250
5
5
----
----
----
DC 125
250
0.4
0.2
----
----
----
8
14
30
125
250
Rated voltage (V)
Motor
load
6
6
4
0.2
0.1
NC
Note: The load is a resistive load.
Operation in the following ranges will produce optimum performance.
5 to 30 VDC
0.16 to 100 mA
Recommended load range
30
10
5
0.8 W
5 mW
1
0.1 0.16
1
5 10
100
Operating characteristics
30 A max. (15 A max. *1)
NO
0.1
DC 30
Note: 1. The above figures are for steady-state currents.
2. Inductive loads have a power factor of 0.4 min. (AC) and a
time constant of 7 ms max. (DC).
3. A lamp load has an inrush current of 10 times the steadystate current.
4. A motor load has an inrush current of 6 times the steadystate current.
Inrush current
Rated current (A) - Resistive load
AC125
Voltage (VDC)
Non-inductive load (A)
Rated
voltage
(V)
Micro-load Switches (Refer to these ratings before using the product.)
High-sensitivity,
High-precision
20 A max. (10 A max. *1)
Current (mA)
Minimum applicable load
5 VDC 1 mA N level reference value
*1. For High-sensitivity and High-precision Switches.
Operating characteristics
Minimum applicable load
Basic
5 VDC 1 mA, resistive load, P level
High-sensitivity,
High-precision
5 VDC 160 mA, resistive load, N level
reference value
Operation indicator Switches
Operation Indicator
Model
Direct-wired connector and Pre-wired Connector type
Non-inductive load (A)
Rated
voltage
(V)
Item
Resistive
load
NC
NO
Lamp
load
NC
NO
3
1.5
Inductive load (A)
Inductive
load
NC
NO
NC
3
Basic
DC
3
3
0.8
Highsensitivity
Highprecision *1
AC 115
3
----
----
----
DC 115
0.4
----
----
----
3
3
0.2
3
3
0.8
Neon lamp
WL-LD-N
WL-LW-N
WL-LD
LED
Leakage current (mA)
125 VAC
Approx. 0.6
250 AC
Approx. 1.9
10 to 24 VAC/DC
Approx. 0.4
115 VAC/DC
Approx. 0.5
NO
AC 115
12
24
115
3
Motor
load
Max. rated voltage (V)
WL-LE-N
WL-LE
3
2.5
3
3
0.2
Note: 1. The above figures are for steady-state currents.
2. Inductive loads have a power factor of 0.4 min. (AC) and a
time constant of 7 ms max. (DC).
3. A lamp load has an inrush current of 10 times the steadystate current.
4. A motor load has an inrush current of 6 times the steadystate current.
Inrush current
NC
3 A max.
NO
3 A max.
Operating characteristics
Minimum applicable load
Basic
5 VDC 1 mA, resistive load, P level
High-sensitivity,
High-precision
5 VDC 160 mA, RESISTIVE Load, N
level reference value
31
WL-N/WL
Characteristics
Degree of protection
Durability *1
15,000,000 operations min. *2
Electrical
750,000 operations min.
(3 A at 250 VAC, resistive load) *3
Mechanical
120 operations/minute min.
Electrical
30 operations/minute min.
Operating speed
Operating
frequency
IP67
Mechanical
1 mm to 1 m/s (for WLCA2-N)
Rated frequency
50/60 Hz
Insulation resistance
100 MΩ min. (at 500 VDC)
Contact resistance
25 mΩ max. (initial value for the
built-in switch when tested alone)
Between terminals
of the same polarity
Dielectric
strength
1,000 VAC (600 VAC) 50/60 Hz
1 min
Between currentcar2,200 VAC (1,500 VAC) 50/60 Hz
rying metal part and
1 min *5
ground
Between each termi2,200 VAC (1,500 VAC) 50/60 Hz
nal and non-current1 min *5
carrying metal part
Vibration
resistance
Shock
resistance
Malfunction
10 to 55 hz, 1.5-mm double
amplitude *6
Destruction
1,000 m/s2 max.
Malfunction
300 m/s2 *6
Ambient operating temperature
-10 to +80°C (with no icing) *7
Ambient operating humidity
35% to 95% RH
Weight
Approx. 255 g (for WLCA2-N)
Note: 1. The above figures are initial values.
2. The figures in parentheses for dielectric strength are those
for the high-sensitivity and high-precision switches models.
*1. The values are calculated at an operating temperature of +5°C to
+35°C, and an operating humidity of 40% to 70% RH.
Contact your OMRON sales representative for more detailed
information on other operating environments.
*2. High-sensitivity models and Flexible Rod models: 10 million
operations min.
500,000 operations min. for Weather-resistant models.
*3. High-sensitivity models, High-precision models, and Weatherproof models are 500,000 operations min.
Micro-load models are 1 million operations min.
Contact your OMRON representative for information on Airtight
models and Hermetic models.
*4. Micro-load models and Weather-proof models are 50 mΩ or less
(default value, built-in switch only).
*5. Sensor I/O connector type is 1,500 V.
*6. Except Flexible Rod models. Micro-load models are 200 m/s2 max.
*7. For low-temperature models this is –40°C to +40°C (with no icing).
For heat-resistant models the range is +5°C to +120°C.
32
WL-N/WL
Spatter-prevention Switches
Ratings
Wiring Specifications
Characteristics
Degree of protection
Screw terminal types
Durability *1
Non-inductive load (A)
Item
Rated
voltage
(V)
WL@-LES-N
AC 125
250
Resistive
load
NC
WL@-LDS-N
NO
10 (5)
10 (5)
Lamp
load
NC
NO
3
2
1.5
1
Inductive load (A)
Inductive
load
NC
NO
10
10
AC 115
10 (5)
3
1.5
10
DC
10
6
0.8 (0.4)
6
4
0.2
3
3
0.2
10
6
0.8
12
24
115
Motor
load
NC
NO
5
3
2.5
1.5
5
2.5
6
4
0.2
Note: 1. The above figures are for steady-state currents.
2. Inductive loads have a power factor of 0.4 min. (AC) and a
time constant of 7 ms max. (DC).
3. A lamp load has an inrush current of 10 times the steadystate current.
4. A motor load has an inrush current of 6 times the steadystate current.
5. The figures in parentheses for resistive load are those for
the high-sensitivity and high-precision switches models.
Inrush current
NC
30 A max. (15 A max. *)
NO
20 A max. (10 A max. *)
Operating characteristics
Minimum applicable load
Basic
5 VDC 1 mA, resistive load, P level
High-sensitivity,
High-precision
5 VDC 160 mA, Resistive load, N level
reference value
Direct-wired connector and Pre-wired Connector type
Non-inductive load (A)
Rated
voltage
(V)
Item
Resistive
load
NC
NO
Lamp
load
NC
NO
3
1.5
Inductive load (A)
Inductive
load
NC
NO
NC
NO
AC 115
3
Basic
DC
3
3
0.8
Highsensitivity
Highprecision *1
AC 115
3
----
----
----
DC 115
0.4
----
----
----
12
24
115
3
3
0.2
3
Motor
load
3
3
3
0.8
2.5
3
3
0.2
Electrical
750,000 operations min.
(3 A at 250 VAC, resistive load) *3
1 mm to 1 m/s (in case of WLCA2LDS-N)
Mechanical
120 operations/minute min.
Electrical
30 operations/minute min.
Rated frequency
50/60Hz
Insulation resistance
100 MΩ min. (at 500 VDC)
Contact resistance
25 mΩ max. (initial value for the
built-in switch)
Between terminals
of the same polarity
Dielectric
strength
1,000 VAC (600 VAC) 50/60 Hz
1 min
Between currentcar2,200 VAC (1,500 VAC) 50/60 Hz
rying metal part and
1 min *4
ground
Between each termi2,200 VAC (1,500 VAC) 50/60 Hz
nal and non-current1 min *4
carrying metal part
Vibration
resistance
Shock
resistance
* For High-sensitivity and High-precision Switches.
15,000,000 operations min. *2
Operating speed
Operating
frequency
IP67
Mechanical
Malfunction
10 to 55 hz, 1.5-mm double amplitude
Destruction
1,000 m/s2 max.
Malfunction
300 m/s2 max.
Ambient operating temperature
-10 to +80°C (with no icing)
Ambient operating humidity
35% to 95% RH
Weight
Approx. 255 g (in case of WLCA2LDS-N)
Note: 1. The above figures are initial values.
2. The figures in parentheses for dielectric strength are those
for the high-sensitivity and high-precision switches models.
*1. The values are calculated at an operating temperature of +5°C to
+35°C, and an operating humidity of 40% to 70%RH.
Contact your OMRON sales representative for more detailed
information on other operating environments.
*2. High-sensitivity models are 10 million operations min.
*3. High-sensitivity models and High-precision models are 500,000
operations min.
Micro-load models are 10 million operations min.
Contact your OMRON representative for information on Airtight
switches.
*4. Sensor I/O connector type is 1,500 V.
Note: 1. The above figures are for steady-state currents.
2. Inductive loads have a power factor of 0.4 min. (AC) and a
time constant of 7 ms max. (DC).
3. A lamp load has an inrush current of 10 times the steadystate current.
4. A motor load has an inrush current of 6 times the steadystate current.
Inrush current
NC
3 A max.
NO
3 A max.
Operating characteristics
Minimum applicable load
Basic
5 VDC 1 mA, resistive load, P level
High-sensitivity,
High-precision
5 VDC 160 mA, Resistive load, N level
reference value
Operation indicator Switches
Operation Indicator
Model
WL-LES-N
WL-LE
WL-LDS-N
WL-LD
Neon lamp
LED
Max. rated voltage (V)
Leakage current (mA)
125 VAC
Approx. 0.6
250 VAC
Approx. 1.9
10 to 24 VAC/DC
Approx. 0.4
115 VAC/DC
Approx. 0.5
33
WL-N/WL
Long-life Switches
Ratings
Wiring Specifications
Characteristics
Degree of protection
Screw terminal type
Rated
voltage
(V)
Item
Non-inductive load
(A)
Resistive
load
NC
Basic
Highsensitivity
Highprecision *
Inductive
load
NC
NO
10
3
1.5
10
DC
10
6
0.8
6
4
0.2
3
3
0.2
10
6
0.8
AC 115
5
DC 115
NC
----
0.4
NO
Motor
load
NC
----
----
----
NC
30 A max. (15 A max. *)
NO
20 A max. (10 A max. *)
* For High-sensitivity and High-precision Switches.
Minimum applicable load
1 mm to 1 m/s
(in case of WLMCA2-LD-N)
Operating speed
Operating
frequency
Mechanical
120 operations/min.
Electrical
30 operations/min.
Rated frequency
50/60 Hz
Insulation resistance
100 MΩ min. (at 500 VDC)
Contact resistance
25 mΩ max. (initial value for the
built-in switch when tested alone)
*2
Between terminals
of the same polarity
Dielectric
strength
(50/60 Hz
1 min.)
Vibration
resistance
1,000 VAC (600 VAC), 50/60 Hz
1 min
Between currentcar2,200 VAC (1,500 VAC) 50/60 Hz
rying metal part and
1 min *3
ground
Between each termi2,200 VAC (1,500 VAC) 50/60 Hz
nal and non-current1 min *3
carrying metal part
Malfunction
10 to 55 Hz, 1.5-mm double amplitude
Destruction
1,000 m/s2 max.
Malfunction
300 m/s2 max. *4
Basic
5 VDC 1 mA, resistive load, P level
Shock
resistance
High-sensitivity,
High-precision
5 VDC 160 mA, Resistive load, N level
reference value
Ambient operating temperature
-10 to +80°C (with no icing)
Ambient operating humidity
35% to 95% RH
Weight
Approx. 255 g
(in case of WLMCA2-LD-N)
Direct-wired connector and Pre-wired Connector type
Rated
voltage
(V)
Item
Non-inductive load
(A)
Resistive
load
NC
NO
Lamp
load
NC
NO
3
1.5
Inductive load (A)
Inductive
load
NC
NO
NC
NO
AC 115
3
Basic
DC
3
3
0.8
Highsensitivity
Highprecision *1
AC 115
3
----
----
----
DC 115
0.4
----
----
----
12
24
115
3
3
0.2
3
Motor
load
3
3
3
0.8
2.5
3
3
0.2
Note: 1. The above figures are for steady-state currents.
2. Inductive loads have a power factor of 0.4 min. (AC) and a
time constant of 7 ms max. (DC).
3. A lamp load has an inrush current of 10 times the steadystate current.
4. A motor load has an inrush current of 6 times the steadystate current.
Inrush current
NC
3 A max.
NO
3 A max.
Operating characteristics
Minimum applicable load
Basic
5 VDC 1 mA, resistive load, P level
High-sensitivity,
High-precision
5 VDC 160 mA, Resistive load, N level
reference value
Operation indicator Switches
Operation Indicator
Model
WL-LD-N
WL-LW-N
WL-LD
34
Durability *1
2.5
6
4
0.2
----
----
Operating characteristics
Electrical
30,000,000 operations min. (10 mA
at 24 VDC, resistive load)
750,000 operations min. (3 A at
115 VAC, resistive load), but for
high-precision models:
High-sensitivity and High-precision
Switches: 500,000 operations min.
NO
5
Note: 1. The above figures are for steady-state currents.
2. Inductive loads have a power factor of 0.4 min. (AC) and a
time constant of 7 ms max. (DC).
3. A lamp load has an inrush current of 10 times the steadystate current.
A motor load has an inrush current of 6 times the steadystate current.
Inrush current
30,000,000 operations min.
Inductive load (A)
AC 115
12
24
115
NO
Lamp
load
IP67
Mechanical
LED
Max. rated voltage (V)
Leakage current (mA)
10 to 24 VAC/DC
Approx. 0.4
115 VAC/DC
Approx. 0.5
Note: 1. The above figures are initial values.
2. The figures in parentheses for dielectric strength are those
for the high-sensitivity and high-precision switches models.
*1. The values are calculated at an operating temperature of +5°C to
+35°C, and an operating humidity of 40% to 70%RH.
Contact your OMRON sales representative for more detailed
information on other operating environments.
*2. For microload models, the contact resistance is 50 mΩ max.
(initial value for built-in switch).
*3. Sensor I/O connector models are 1,500 V.
*4. Micro-load models are 200 m/s2 max.
WL-N/WL
General-purpose/Environment-resistant/Spatter-prevention/Long-life Switches
Approved Standards
Agency
Standard
UL
UL508
File No.
CSA cUL
CSA C22.2 No.14
TÜV Rheinland
EN60947-5-1
CCC (CQC)
GB14048.5
Approved models
Contact your OMRON representative for information
Contact your OMRON representative for information
Approved Standard Ratings
UL/cUL, CSA (UL508, CSA C22.2 No.14)
Specifications
Indicator
No
indicator
Approved
Standards
Rated voltage
Basic Switches
A600
1 A, 125 VDC
High-sensitivity or
high-precision
A600
120 VAC
240 VAC
480 VAC
600 VAC
Basic, high-sensitivity
or high-precision
C300
3 A, 250 VAC
Sensor I/O connectors
No Connector
Pre-wired Connector (AC)
Item
Basic Switches
Pre-wired Connector (DC)
Direct-wired Connector (DC) High-sensitivity or
high-precision
Basic Switches
Neon
lamp
No Connector
High-sensitivity or
high-precision
Pre-wired Connector (AC)
Basic, high-sensitivity
or high-precision
Rated voltage
0.8 A, 125 VDC
120 VAC
240 VAC
A300
10 A, 250 VAC
C300
3 A, 250 VAC
A150
10 A, 115 VAC
1 A, 115 VDC
High-sensitivity or
high-precision
A150
10 A, 115 VAC
0.8 A, 115 VDC
LED
Basic, high-sensitivity
or high-precision
Basic Switches
Pre-wired Connector (DC)
Direct-wired Connector (DC) High-sensitivity or
high-precision
C150
3 A, 115 VAC
1 A, 115 VDC
0.8 A,
115 VDC
TÜV (EN 60947-5-1)
With ground terminals
Neon
lamp
With DC
Connector
LED
Working load
category
AC-15
DC-12
AC-15
AC-15
DC-12
DC-12
Rated working
voltage (Ue)
250 V
48 V
250 V
115 V
48 V
48 V
Rated working
current (Ie)
2A
Conditional
short-circuit
current
Short-circuit
protective
device (SCPD)
100 A
10 A, fuse type gG
Rated insulation
voltage (Ui)
250 V
48 V
Rated impulse
dielectric
strength (Uimp)
4 kV
800 V
Pollution degree
Electric shock
protection class
Volt-ampere (VA)
Break
Make
Break
60
30
15
12
6
3
1.5
1.2
7,200
720
Energizing
current
2.5 A
Current (A)
Volt-ampere (VA)
Make
Break
Make
Break
15
7.5
1.5
0.75
1,800
180
A300 Authentication conditions
Rated voltage
120 VAC
240 VAC
Energizing
current
10 A
Current (A)
Volt-ampere (VA)
Make
Break
Make
Break
60
30
6
3
7,200
720
A150 Authentication conditions
Current (A)
Volt-ampere (VA)
Rated voltage
Energizing
current
Make
Break
Make
Break
120 VAC
10 A
60
6
7,200
720
C150 Authentication conditions
Current (A)
Rated voltage
Energizing
current
Make
120 VAC
2.5 A
15
Authentication
conditions
Specification
No indicator
10 A
Current (A)
Make
Volt-ampere (VA)
Break
1.5
Make
Break
1,800
180
CCC (GB14048.5)
(Certification Only for Switches with Ground Terminals and DC
Switches with Connectors)
Authentication
conditions
Energizing
current
C300 Authentication conditions
1 A, 125 VDC
Basic Switches
No Connector
Pre-wired Connector (AC)
A600 Authentication conditions
Specification
No
indicator
Neon
lamp
LED
Working load
category
AC-15 DC-13 AC-15 AC-15 DC-13
Rated working
voltage (Ue)
250 V
Rated working
current (Ie)
Conditional
short-circuit
current
48 V
250 V 250 V
With DC
Connector
With AC
Connector
DC-13
AC-15
48 V
250 V
48 V
2A
1000 A
Short-circuit
protective
device (SCPD)
10 A, fuse type gG
Rated insulation
voltage (Ui)
250 V
3
Class I
Class III
35
WL-N/WL
Structure and Nomenclature
General-purpose Switches: WLCA2-N
Actuator
Standard Switches
Basic Switches
Head-mounting Screws
Roller
The roller is made of self-lubricating
sintered stainless steel and boasts high
resistance to wear.
Head
Lever
The lever is forged from corrosion-resistant
aluminum alloy. It provides superior
corrosion resistance and outstanding
strength.
With roller lever, adjustable rod and flexible
rod models, the actuator position can be set
anywhere within 360°. (The lever cannot be
mounted in the opposite direction.)
You can remove the two screws to
mount the switch in any of the four
possible orientations.
Shaft Section Seal
An oil seal is fitted on the inlet of the
shaft section to maintain a tight seal.
Roller Lever Bolt
Operational Plunger
Set Position Marker Plate
Set the indicator needle so
that it is between protrusions
on the bearing section on the
marker plate after operation.
Head
Set position marker plate
You can change the direction of the
operational plunger to electrically switch
the direction of operation between both
sides, left only, or right only.
Built-in Switch
Built-in switch with SPST-NO+NC
contact form.
Requires maintenance (excessive overtravel)
Proper range
Requires maintenance (insufficient overtravel)
Proper range
Terminal Screws
Four, M3.5 screws
Requires maintenance (excessive overtravel)
Cover Setscrew
A combination Philips-slotted screw is used.
A retainer prevents the screw from falling
from the cover even when the screw is loose.
Cover
Cover Seal
High sealing performance is achieved. The
seal also serves as a spacer.
There is no troublesome insulating paper,
making it easy to work with the Switch.
36
Conduit Opening
The conduit screw is a parallel screw
for G1/2 piping, and is used together
with an SC connector to maintain a
tight seal.
WL-N/WL
General-purpose Switches:
WLG2
Standard Switches
Head-mounting Screws
Head
By removing the four corner screws, the
head can be mounted in any of four
orientations.
High-sensitivity and High-precision Switches
Actuator
Roller
The roller is made of self-lubricating
sintered stainless steel and boasts
high resistance to wear.
Lever
Shaft Section Seal
By fitting an O-ring to the rotary shaft
and with an appropriate interference
of the screws, high-sealing properties
are maintained.
The lever forged of anti-corrosive
aluminium alloy features high corrosion
resistances and outstanding ruggedness.
With roller lever, adjustable rod and
flexible rod models, the actuator position
can be set anywhere within 360°. (The
lever cannot be mounted in the opposite
direction.)
Roller Lever Setscrew
Operational Plunger
Bearing
The bearing smooths the
plunger movement.
Set Position Marker Plate
After operation, set the indicator needle
on the marker plate so that is in the
convex section of the bearing.
Built-in Switch
Built-in switch with SPST-NO+NC
contact form.
Requires maintenance
(excessive overtravel)
Proper range
Requires maintenance (insufficient overtravel)
Proper range
Requires maintenance
(excessive overtravel)
Terminal Screws
Four, M4 screws
Separator
The separator has outstanding insulation
properties and prevents the generation of any
gases which may corrode the internal parts.
Conduit Opening
The conduit screw is a parallel screw for G1/2
piping, and is used together with an SC
connector to maintain a tight seal.
Cover Seal
By using a packing seal as the cover seal,
an optimum squeeze can be obtained and
high sealing properties are assured as well.
Cover
Cover Setscrew
A combination Philips-slotted screw is used.
A retainer prevents the screw from falling from
the cover even when the screw is loose.
37
WL-N/WL
Basic Switches
Operation indicator Switches
Indicator Covers
Indicator
The indicator covered if outsert molded
from diecast aluminum and has outstanding
sealing properties.
The indicator is either a neon lamp or an
LED. Switches with LED indicators have a
built-in rectifier stack, so there is no
connection polarity.
Indicator Windows
Operating status (i.e., light-ON when
operating or light-ON when not operating)
depends on whether a neon lamp or an
LED is used.
Contact Spring
Light-ON when Operating/Not Operating
Lamp Holder
Indicators can be switched from light-ON
when operating and light-ON when not
operating, by simply rotating the indicator
holder by 180°.
(However, Direct-wired Connector,
Pre-wired Connector, Three-core, and
Four-core Switches cannot be switched to
light-ON when operating (NC wiring).)
Light-ON when Operating
The built-in switch's terminal screws
are used to connect the indicator
terminal. Since the connection spring
(coil spring) is used for this connection,
it will not be necessary to connect the
indicator terminal. When a ground
terminal is provided however, a lead
wire must be used.
Light-ON when Not Operating
LED at top
LED at bottom
Operation
Light-ON when Not Operating
Internal Circuits
Power
Neon lamp
Built-in switch
Light-ON when
operating *1
14
Za
WL@-LE-N
13
Contact spring
Resistor
11
12
Load
Internal
circuits
WL@-LE-N
WL@-LD-N
WL@-LW-N
Internal
circuits
Light-ON when not
operating *2
Rectifier stack
Contact spring
Power
Resistor
Za
14
13
11
12
Load
WL@-LD-N
WL@-LW-N
Zener
diode
Rated
current
diode
Resistor
LED
Built-in switch
Note: Leakage current from indicator circuit may cause load malfunction (i.e., the load may remain ON). Make sure that the load operating current
is higher than the leakage current.
For countermeasures, refer to technical support on your OMRON website.
*1. Light-ON when operating means that the lamp lights when the Limit Switch contacts (NC) release, or when the actuator rotates or is pushed
down.
*2. Light-ON when not operating means the lamp remains lit when the actuator is free, or when the Limit Switch contacts (NO) close when the
actuator rotates or is pushed down.
38
WL-N/WL
High-sensitivity and High-precision Switches
Operation indicator Switches
Indicator Covers
Indicator
The indicator covered if outsert molded from
diecast aluminum and has outstanding sealing
properties.
The indicator is either a neon lamp or an
LED. Switches with LED indicators have a
built-in rectifier stack, so there is no
connection polarity.
Indicator Windows
Operation (i.e., light-ON when operating or
light-ON when not operating) depends on
whether a neon lamp or LED is used.
Contact Spring
The built-in switch's terminal screws are
used to connect the indicator terminal.
Since the connection spring (coil spring) is
used for this connection, it will not be
necessary to connect the indicator terminal.
When a ground terminal is provided
however, a lead wire must be used.
Light-ON when Operating/Not Operating
Indicators can be switched from light-ON when
operating and light-ON when not operating, by
simply rotating the indicator holder by 180°.
(However, Direct-wired Connector, Pre-wired
Connector, Three-core, and Four-core Switches
cannot be switched to light-ON when operating
(NC wiring).)
Light-ON when Operating
Light-ON when Not Operating
LED at top
LED at bottom
Operation
Internal Circuits
Power
Light-ON when Not
Operating
Neon lamp
Built-in switch
Light-ON when
operating *1
4
Za
WLG@-LE
3
Contact spring
Resistor
1
2
Load
Internal circuits
WLG@-LE
WLG@-LD
Rectifier stack
Contact spring
Power
Resistor
Internal circuits
Light-ON when
not operating *2
WLG@-LD
Za
4
3
1
2
Load
Zener
diode
Rated
current
diode
Resistor
LED
Built-in switch
Note: Leakage current from indicator circuit may cause load malfunction (i.e., the load may remain ON). Make sure that the load operating current
is higher than the leakage current.
For countermeasures, refer to technical support on your OMRON website.
*1. Light-ON when operating means that the lamp lights when the Limit Switch contacts (NC) release, or when the actuator rotates or is pushed
down.
*2. Light-ON when not operating means the lamp remains lit when the actuator is free, or when the Limit Switch contacts (NO) close when the
actuator rotates or is pushed down.
39
WL-N/WL
Basic Switches
Environment-resistant Switches
Molding Specifications for Hermetic Switches
WL@-139-N
: Molded parts
WL@-140-N
WL@-141-N
Head cap
Airtight
built-in switch
Standard
built-in switch
WL@-145-N
Head cap
Oil seal
Airtight
built-in switch
WL@-RP40-N
WL@-RP60-N *1
Oil seal
Airtight
built-in switch
Airtight
built-in switch
Airtight
built-in switch
*1. Fluorine rubber is used for all rubber parts.
Model
WL@-139-N
WL@-140-N
WL@-141-N
WL@-145-N
WL@-RP40-N
WL@-RP60-N
Cable specifications
Standard 5-m VCT cable.
Finished outer diameter: 11.5 mm, 4 conductors.
Standard 5-m VCT cable, with high flexibility and good
anti-oil properties attached. Finished outer diameter:
11.5 mm, 4 conductors.
Connector specifications
Resin cap
Metal connector
Resin connector *2
Resin cap
*2. The connector can be removed, so it is possible to use flexible conduit for the cable.
40
WL-N/WL
High-sensitivity and High-precision Switches
Environment-resistant Switches
Mold Specifications for Hermetic Seal Switches
: Molded parts
WLG@-139
WLG@-140
WLG@-141
Oil seal for protection against cutting powder
X-ring
Standard
built-in
switch
Airtight
built-in
switch
WLG@-145
Airtight
built-in
switch
WLG@-RP40
Oil seal for protection against cutting powder
X-ring
WLG@-RP60 *1
O-ring
Airtight
built-in
switch
Airtight
built-in
switch
Airtight
built-in
switch
*1. Fluorine rubber is used for all rubber parts.
Model
WLG@-139
WLG@-140
WLG@-141
WLG@-145
WLG@-RP40
WLG@-RP60
Cable specifications
Standard 5-m VCT cable.
Finished outer diameter: 11.5 mm, 4 conductors.
Standard 5-m VCT cable, with high flexibility and good
anti-oil properties attached. Finished outer diameter:
11.5 mm, 4 conductors.
Connector specifications
Resin cap
Metal connector
Resin connector *2
Resin cap
*2. The connector can be removed, so it is possible to use flexible conduit for the cable.
41
WL-N/WL
Spatter-prevention Switches: WLCA2-LES-N
Basic Switches
Actuator
Roller, Roller Axis
Using stainless steel prevents
spatter from adhering.
Operating Lever
A baking finish is applied to the surface
so that any adhering spatter is easily
removed.
Roller Lever Bolt
Stainless steel construction to prevent
spatter adherence.
Double nut models are also available.
Screws
Externally visible screws on the head and
cover are made of stainless steel to prevent
spatter adherence.
Head Cap
Using fluororesin prevents spatter from
adhering.
* Spatter means the zinc powder produced
when welding.
Adhering spatter to the Limit Switch may
cause malfunction of lever or lamp cover.
The lack of gap prevents spatter
powder from clogging.
Spatter-prevention Switches: WLG2-LEAS
High-sensitivity and High-precision Switches
Actuator
Roller, Roller Axis
Using stainless steel prevents spatter
from adhering.
Operating Lever
A baking finish is applied to the surface so
that any adhering spatter is easily removed.
Double Nut
SUS is used for double nut.
Lamp Cover
· Heat-resistant resin is used for the lamp
cover.
· By using spherical surface for the display
part, it disperses the direction of spatter.
42
Screws
Externally visible screws on the head and
cover are made of stainless steel to prevent
spatter adherence.
Head Cap
Using fluororesin prevents spatter from
adhering.
* Spatter means the zinc powder produced
when welding.
Adhering spatter to the Limit Switch may
cause malfunction of lever or lamp cover.
The lack of gap prevents spatter
powder from clogging.
WL-N/WL
Long-life Switches: WLMCA2-N
Basic Switches
Head Cap
Head
The head cap helps prevent the entry of cutting
chips.You can use the protrusion on the cap to
confirm the set position.
You can remove the two screws to mount the head in
any of the four possible directions.
Actuator
Shield Structure
Roller
A head cap and oil seal form a double-seal structure.
Excellent durability and reliability are ensured.
The roller is made of self-lubricating sintered
stainless steel.
It provides superior resistance to wear.
Lever
The lever is forged from anti-corrosive aluminum
alloy. It provides superior corrosion resistance and
outstanding strength. With a roller lever actuator,
the actuator position can be set anywhere within
360°. (The lever cannot be mounted in the opposite
direction.)
Oil seal
Head cap
Operating Plunger
PEEK resin is used. It provides superior resistance to
wear. You can change the mounting direction to use
any one of the three operating directions (both sides,
left side, or right side).
Built-in Switch
Built-in switch with an
SPST-NO+NC contact form.
Cover Seal
High sealing performance is achieved. The seal also
serves as a spacer.
There is no troublesome insulating paper, making it
easy to work with the Switch.
Terminal Screws
Four, M3.5 screws.
Cover Setscrew
Conduit Opening
In addition to parallel threads for G1/2 tubing,
direct-wired and pre-wired connector types are available.
Cover
A combination Philips-slotted screw is used.
A retainer prevents the screw from falling
from the cover even when the screw is loose.
43
WL-N/WL
Long-life Switches: WLMG2
High-sensitivity/High-precision Switches
Release Plunger
Set Position Marker Plate
The set position is easy to view.
Hardening method changed for greater
abrasion resistance.
The stroke is indicated in fluorescent color that
is visible from the slit in the rubber cap.
Long-life Model
Standard Model
Stainless
steel +
Hardening
Sintered
alloy
Head
The Head can be mounted in any of the
four directions by removing the screws
at the four corners of the Head.
Fluorescent paint
Shaft Section Seal
Requires maintenance (excessive overtravel)
Proper range
Requires maintenance (insufficient overtravel)
Proper range
By fitting a double seal consisting of an
oil seal and an X-ring to the rotary
shaft, even greater sealing properties
are achieved.
Requires maintenance (excessive overtravel)
Actuator
Oil seal
Head
Mounting
Screws
X-ring
Roller
The roller is made of self-lubricating stainless
sintered and boasts high resistance to wear.
Lever
Smoother Movement
A grease holder is provided on the
shaft to prevent the grease from
running out.
The lever forged of anti-corrosive aluminium
alloy features high corrosion resistance and
outstanding ruggedness. With roller lever
models, the actuator position can be set
anywhere within 360°. (The lever cannot be
mounted in the opposite direction.)
Standard Model
Operational Plunger *
Cover Seal
By using a packing seal as the
cover seal, an optimum squeeze
can be obtained and high sealing
properties are assured as well.
Long-life Model
Terminal Screws
Grease holder
Four, M4 screws
Smooth movement is achieved using
olefin grease. (Standard models use
molybdenum disulfide grease.)
Cover
Separator
Bearing
The separator has outstanding
insulation properties and prevents
the generation of any gases
which may corrode the internal
parts.
The bearing smooths the plunger
movement.
Built-in Switch
Built-in switch with SPST-NO+NC
contact form.
Cover Mounting Screw
Conduit Opening
In addition to parallel threads for G½ tubing,
direct-wired and pre-wired connector types are
available.
44
Phillips screws are used to
ensure ease of use.
WL-N/WL
Dimensions and Operating Characteristics
(Unit: mm)
General-purpose and Environment-resistant Switches
Standard Switches
Switches with Roller Lever Actuators
Basic Switches
Roller lever R38
Roller lever R50
WLCA2-N
WLCA2-2-N
WLCA2-2N-N
WLCA2-7-N
17.5×7 dia. *
60 max.
53±1.5
41.5±1.5
40±1.5
25.4
13.1
17.5×15 dia. *
12.7
Two, M3.5
Two, M3.5
R50
R38
(125)
14.7
12.7
(137) 14.7
68.7
Three, M4
21.6
(15.1)
30.2±0.2
40±0.7
JIS B 0202 G½
29.2±1.2
42 max.
53.2±0.8
68.7
58.7±0.2
5
(4.9)
Three, M4
5
Four, M6
Depth: 15 min.
(4.9)
21.6
(15.1)
Adjustable roller lever
WLCA2-8-N
WLCA12-N
WLCA12-2-N
WLCA12-2N-N
60 max.
53±1.5
41.5±1.5
40±1.5
17.5×7 dia. *
17.5×7 dia. *
25.4
13.1
R63
Two, M3.5
Two, M3.5
Adjustable range:
25 to 89
12.7
M5
Allen-head bolt
Four, 5.2 dia.
holes
58.7±0.2
68.7
5
(4.9)
JIS B 0202 G½
40±0.7
29.2±1.2
42 max.
53.2±0.8
Four, M6
Depth: 15 min
* Stainless sintered roller
25.4
M5
Allen-head
bolt
58.7±0.2
21.6
41.5±1.5
25.4
13.1
12.7
14.7
Three, M4
(15.1)
30.2±0.2
Four, M6
Depth: 15 min
67 max.
60±1.5
Four, 5.2 dia. holes
25.4
5
(4.9)
29.2±1.2
42 max.
53.2±0.8
* Stainless sintered roller
Roller lever R63
14.7
JIS B 0202 G½
30.2±0.2
40±0.7
* Stainless sintered roller
(150)
25.4
M5
Allen-head bolt
Four, 5.2 dia. holes
58.7±0.2
25.4
13.1
Four, 5.2 dia.
holes
25.4
M5
Allen-head bolt
67.2 max.
58.1±1.5
41.5±1.5
36±1.5
68.7
Three, M4
(15.1)
30.2±0.2
40±0.7
JIS B 0202 G½
21.6
29.2±1.2
42 max.
65.2±0.8
Four, M6
Depth: 15 min
* Stainless sintered roller
Note: Unless otherwise indicated, a tolerance of ±0.4 mm applies to all dimensions.
Model
Operating characteristics
Operating force
Release force
Pretravel
Overtravel
Movement Differential
OF
RF
PT
OT
MD
max.
min.
min.
max.
Model
Operating characteristics
Operating force
Release force
Pretravel
Overtravel
Movement Differential
OF
RF
PT
OT
MD
max.
min.
min.
max.
WLCA2-N
WLCA2-2-N
WLCA2-2N-N
WLCA2-7-N
WLCA2-8-N
13.34 N
1.18 N
15±5°
70°
12°
13.34 N
1.18 N
25±5°
60°
16°
13.34 N
1.18 N
20° max.
70°
10°
10.2 N
0.9 N
15±5°
70°
12°
8.04 N
0.71 N
15±5°
70°
12°
WLCA12-N *1
WLCA12-2-N *1
WLCA12-2N-N *1
13.34 N
1.18 N
15±5°
70°
12°
13.34 N
1.18 N
25±5°
60°
16°
13.34 N
1.18 N
20° max
70°
10°
* The operating characteristics are measured at the lever length of 38 mm.
45
WL-N/WL
Switches with Roller Lever Actuators
Basic Switches
Adjustable rod lever 25 to 140 mm
Adjustable rod lever
WLCL-N
WLCL-2-N
WLCL-2N-N
WLCAL4-N
67 max.
8
9
3.2 dia. *
55 max.
46±1.5
3±0.2 dia.
(length:160) *
Adjustable range:
25 to 140
Two, M3.5
M8
Allen-head
set screw
41.5±1.5
25.4
13.1
12.7
Adjustable range:
350 to 380
12.7
65
Four, 5.2 dia.
holes
25.4
M5
Allen-head
set screw
Three, M4
68.7
58.7±0.2
5
25.4
M5
Allen-head
set screw
Four, 5.2 dia.
holes
14.7
14.7
58.7±0.2
54.5±1.5
12.8
41.5±1.5
25.4
13.1
68.7
Three, M4
5
(4.9)
(15.1)
30.2±0.2
40±0.7
JIS B 0202 G½
(4.9)
21.6 Four, M6
Depth: 15 min.
29.2±1.2
42 max.
(15.1)
30.2±0.2
40±0.7
JIS B 0202 G½
21.6
29.2±1.2
42 max.
Four, M6
Depth: 15 min.
* Stainless steel rod
* Stainless steel rod
Rod spring lever
WLCAL5-N
67 max.
7.5
2.3 dia. *
428.5±2
54.5±1.5
41.5±1.5
25.4
65
13.1
12.7
Four, 5.2
dia. holes
11
14.7
25.4
M5
Allen-head
bolt
68.7
58.7±0.2
Three, M4
5
(4.9)
(15.1)
30.2±0.2
40±0.7
JIS B 0202 G½
21.6
29.2±1.2
42 max.
Four, M6
Depth: 15 min.
* Piano wire
Note: Unless otherwise indicated, a tolerance of ±0.4 mm applies to all dimensions.
Model
Operating characteristics
Operating force
Release force
Pretravel
Overtravel
Movement Differential
OF
RF
PT
OT
MD
max.
min.
min.
max.
WLCL-N *1
WLCL-2-N *1
WLCL-2N-N *1
WLCAL4-N *2
WLCAL5-N
1.39 N
0.27 N
15±5°
70°
12°
1.39 N
0.27 N
25±5°
60°
16°
1.39 N
0.27 N
20° max
70°
10°
0.98 N
0.15 N
15±5°
70°
12°
0.9 N
0.09 N
15±5°
70°
12°
Note: The actuator on the WLCAL4-N and WLCAL5-N is heavy, which may result in resetting problems depending on the direction the Switch is
mounted. Mount the Switch so that the actuator is facing downwards to prevent this problem from occurring.
*1. The operating characteristics are measured at the lever length of 140 mm.
*2. The operating characteristics are measured at a rod length of 380 mm.
46
WL-N/WL
Switches with Roller Lever Actuators
High-sensitivity Switches
Roller lever R38
Adjustable rod lever 25 to 140 mm
WLG2
WL01G2
17.5 dia. (length: 7) *
9
3 ±0.2 dia.
(length: 160) *
25.4
12.7
Four, M3.5
38R
WLGL
WL01GL
60 max.
53 ±1.5
41.5 ±1.5
40 ±1.5
13.1
M5 (length: 12)
Allen-head bolt
Adjustable range:
25 to 140
Four, M3.5
14.7
68.7
58.7 ±0.2
JIS B0202 G½
(15.1)
Effective thread:
30.2 ±0.2
4 threads min.
40 ±0.7
* Stainless sintered roller
21.6
Four, M6
Depth: 15 min.
±1.2
29.2
35
42 max.
53.2 ±0.8
68.7
Three, M4
(length: 13)
5
(4.9)
25.4
M5 (length: 12)
Allenhead bolt
Four, 5.2 +0.2
0
dia. holes
14.7
Four, 5.2 +0.2
0
dia. holes
Three, M4
(length: 13)
25.4
12.7
M8 (length: 12)
Allen-head
lock screw
25.4
(125)
58.7 ±0.2
55 max.
46 ±1.5
41.5 ±1.5
13.1
5
(4.9)
(15.1)
30.2 ±0.2
40 ±0.7
JIS B0202 G½
Effective thread:
4 threads min.
21.6
±1.2
29.2
35
42 max.
Four, M6
Depth: 15 min.
* Stainless sintered roller
Adjustable Roller Lever R38
WLG12
WL01G12
67 max.
60 ±1.5
41.5 ±1.5
13.1
17.5 dia. (length: 7) *
25.4
12.7
Four, M3.5
M5 (length: 16)
Allen-head
bolt
Four, 5.2 +0.2
0
dia. holes
Adjustable range:
25 to 89
14.7
58.7 ±0.2
25.4
68.7
Three, M4
(length: 13)
5
21.6
(15.1)
30.2 ±0.2
40 ±0.7
(4.9)
Four, M6
Depth: 15 min.
±1.2
JIS B0202 G½
Effective thread:
4 threads min.
29.2
35
42 max.
65.2 ±0.8
* Stainless sintered roller
Note: 1. Unless otherwise indicated, a tolerance of ±0.4 mm applies to all dimensions.
Switches with High-precision Actuators
Roller lever R38
60 max.
WLGCA2
WL01GCA2
17.5 dia. (length: 7) *
25.4
12.7
Four, M3.5
38R
(125)
53 ±1.5
41.5 ±1.5
40 ±1.5
13.1
M5 (length: 12)
Allen-head bolt
25.4
14.7
Four, 5.2 +0.2
0
dia. holes
68.7
58.7 ±0.2
Three, M4
(length: 13)
5
(4.9)
(15.1)
30.2 ±0.2
40 ±0.7
JIS B0202 G½
Effective thread:
4 threads min.
* Stainless sintered roller
21.6
±1.2
29.2
Four, M6
Depth: 15 min.
35
42 max.
53.2 ±0.8
Note: 1. Unless otherwise indicated, a tolerance of ±0.4 mm applies to all dimensions.
Model
Operating characteristics
Operating force
Release force
Pretravel
Overtravel
Movement Differential
OF
RF
PT
OT
MD
max.
min.
min.
max.
WLG2
WL01G2
9.81 N
0.98 N
+2°
10° −1°
65°
7°
WLG12 *1
WL01G12 *1
WLGL *2
WL01GL *2
WLGCA2
WL01GCA2
9.81 N
0.98 N
+2°
10° −1°
65°
7°
2.84 N
0.25 N
+2°
10° −1°
65°
7°
13.34 N
1.47 N
+2°
5° 0°
40°
3°
*1. The operating characteristics are measured at the lever length of 38 mm.
*2. The operating characteristics are measured at a rod length of 140 mm.
47
WL-N/WL
Switches with Plunger Actuators
Basic Switches
Sealed top plunger
WLD18-N
Horizontal plunger
10 dia.
13.1
R1 *
12.9
PT
25.4
13.1
Two, M3.5
12.7
25 dia. *2 R1
Two, M3.5
OP
27.5
17.8
9.3 dia. *1
(96.2)
Four, 5.2 dia. holes
58.7±0.2
Four, 5.2 dia. holes
58.7±0.2
68.7
68.7
Three, M4
Three, M4
5
(4.9)
* Stainless steel plunger
OP
46.6±0.8
PT
WLSD-N
(15.1)
30.2±0.2
JIS B 0202 G½
40±0.7
21.6
29.2±1.2
42 max.
Four, M6
Depth: 15 min
*1. Stainless steel plunger
*2. Cosmetic nuts
5
(4.9)
(15.1)
30.2±0.2
JIS B 0202 G½
40±0.7
Sealed top-roller plunger
21.6
29.2±1.2
42 max.
Four, M6
Depth: 15 min
Horizontal-roller plunger
13.1
WLD28-N
14.3 dia.×5 *
PT
WLSD2-N
12.9
PT
25.4
OP
55.7±0.8
Two, M3.5
13.1
12.7
25 dia. *2
Two, M3.5
OP
27.5
17.8
17 dia.×4.6 *1
(96.2)
Four, 5.2 dia. holes
58.7±0.2
Four, 5.2 dia. holes
58.7±0.2
68.7
68.7
Three, M4
Three, M4
5
5
(4.9)
*Stainless sintered roller
(15.1)
30.2±0.2
JIS B 0202 G½
40±0.7
21.6
29.2±1.2
42 max.
Four, M6
Depth: 15 min
(15.1)
30.2±0.2
JIS B 0202 G½
Horizontal-ball plunger
13.1
12.9
15.5 dia.
1/2" dia. *
PT
(4.9)
40±0.7
Sealed top-ball plunger
WLD38-N
*1. Stainless sintered roller
*2. Cosmetic nuts
WLSD3-N
PT
25.4
21.6
29.2±1.2
42 max.
OP
46.6±0.8
Two, M3.5
13.1
12.7
25 dia. *2
Two, M3.5
OP
Four, M6
Depth: 15 min
15.5 dia.
27.5
17.8
1/2" dia. *1
(96.2)
Four, 5.2 dia. holes
58.7±0.2
Four, 5.2 dia. holes
58.7±0.2
68.7
68.7
Three, M4
Three, M4
5
* Stainless steel ball
(4.9)
(15.1)
30.2±0.2
40±0.7
JIS B0202 G½
21.6
29.2±1.2
42 max.
Top-roller plunger
WLD2-N
Four, M6
Depth: 15 min
* 1. Stainless steel ball
* 2. Cosmetic nuts
5
(4.9)
(15.1)
30.2±0.2
JIS B0202 G½
40±0.7
21.6
29.2±1.2
42 max.
Four, M6
Depth: 15 min
13.1
12.9
17 dia.×4.6 *
PT
Four, M3.5
OP
28.4
Four, 5.2 dia. holes
68.7
58.7±0.2
Three, M4
*Stainless sintered roller
5
(4.9)
(15.1)
30.2±0.2
40±0.7
JIS B0202 G½
21.6
29.2±1.2
42 max.
Four, M6
Depth: 15 min
Note: Unless otherwise indicated, a tolerance of ±0.4 mm applies to all dimensions.
Model
Operating characteristics
48
WLD18-N
WLD28-N
WLD38-N
WLD2-N
WLSD-N
WLSD2-N
WLSD3-N
Operating force
Release force
Pretravel
Overtravel
Movement Differential
OF
RF
PT
OT
MD
max.
min.
max.
min.
max.
26.67 N
8.92 N
1.7 mm
6.4 mm
1 mm
16.67 N
4.41 N
1.7 mm
5.6 mm
1 mm
16.67 N
4.41 N
1.7 mm
5.6 mm
1 mm
26.67 N
8.92 N
1.7 mm
5.6 mm
1 mm
40.03 N
8.89 N
2.8 mm
5.6 mm
1 mm
40.03 N
8.89 N
2.8 mm
5.6 mm
1 mm
40.03 N
8.89 N
2.8 mm
4 mm
1 mm
Operating position
Total travel position
OP
TTP
max.
34±0.8 mm
29.5 mm
44±0.8 mm
39.5 mm
44.5±0.8 mm
41 mm
44±0.8 mm
39.5 mm
40.6±0.8 mm
---
54.2±0.8 mm
---
54.1±0.8 mm
---
WL-N/WL
Switches with Flexible Rod Actuators
Basic Switches
Coil spring
Coil Spring (Multi-wire)
WLNJ-N
WLNJ-30-N
*1
PT
*1
6.5 dia.
PT
*3
4.8 dia.
*3
*2
*2
(107)
(107)
140±2.5
140±2.5
13.1
12.9
13.1
12.9
Two, M3.5
Two, M3.5
33.7±0.8
33.7±0.8
Four, 5.2 dia. holes
58.7±0.2
Four, 5.2 dia. holes
68.7
58.7±0.2
Three, M4
5
(15.1)
30.2±0.2
(4.9)
JIS B 0202 G½
40±0.7
68.7
Three, M4
21.6
29.2±1.2
42 max.
5
Four, M6
Depth: 15 min
(4.9)
(15.1)
30.2±0.2
JIS B 0202 G½
40±0.7
*1. Do not operate the Switch in the direction of the axial center.
*2. Stainless steel coil spring.
*3. The range for operation is 1/3rd of the overall spring length from the end of the spring.
Resin rod
21.6
29.2±1.2
42 max.
Four, M6
Depth: 15 min
*1. Do not operate the Switch in the direction of the axial center.
*2. Piano wire coil spring.
*3. The range for operation is 1/3rd of the overall spring length from the end of the spring.
Steel wire
WLNJ-2-N
WLNJ-S2-N
*1
PT
*1
8 dia.
*3
1 dia
PT
*3
*2
(95.4)
(159)
140±2.5
*2
193±2.5
13.1
12.9
26 dia.
13.1
12.9
Two, M3.5
44.6±0.8
Two, M3.5
33.7±0.8
Four, 5.2 dia. holes
Four, 5.2 dia. holes
58.7±0.2
68.7
58.7±0.2
68.7
Three, M4
Three, M4
5
(4.9)
(15.1)
30.2±0.2
JIS B0202 G½
40±0.7
21.6
29.2±1.2
42 max.
5
Four, M6
Depth: 15 min
(4.9)
(15.1)
30.2±0.2
JIS B 0202 G½
40±0.7
*1. Do not operate the Switch in the direction of the axial center.
*2. Polyamide Resin Rod
*3. The range for operation is 1/3rd of the overall rod length from the end of the rod.
21.6
29.2±1.2
42 max.
Four, M6
Depth: 15 min
*1. Do not operate the Switch in the direction of the axial center.
*2. Stainless steel wire.
*3. The range for operation is 1/3rd of the overall wire length from the end of the wire.
Note: Unless otherwise indicated, a tolerance of ±0.4 mm applies to all dimensions.
Model
Operating characteristics
Operating force
Pretravel
OF
PT
max.
WLNJ-N
WLNJ-30-N
WLNJ-2-N
WLNJ-S2-N
1.47 N
20±10 mm
1.47 N
20±10 mm
1.47 N
40±20 mm
0.28 N
40±20 mm
* These values are for the top end of the spring, rod, or wire.
49
WL-N/WL
Switches with Fork Lock Lever Actuators
Retention Switches
General-purpose
WLCA32-41-N
WLCA32-42-N
WLCA32-43-N
WLCA32-44-N
The WLCA32-41-N is shown in the following
diagram.
Two, 17.5×7 dia. *
90°±3°
62.5 max.
56.4±3.5
42.8±3.5
25.4 13.1
12.7
R38
Two, M3.5
14.7
34.1
M5 Allen-head
set screw
Four, 5.2 dia.
holes
Three, M4
(125)
58.7±0.2
68.7
5 (15.1)
21.6
JIS B 0202 G½
(4.9)
30.2±0.2
29.2±1.2
40±0.7
42 max.
4-M6
Four, M6
Depth: 15 min.
* Plastic Roller
(The WLCA32-041-N to WLCA32-044-N have stainless steel rollers.)
Note: 1. Unless otherwise indicated, a tolerance of ±0.4 mm applies to all dimensions.
Model
Operating characteristics
Force necessary to reverse the direction of the lever
Movement until the lever reverses
Movement until switch operation
Movement after switch operation
WLCA32-41 to 44-N
max.
11.77N
50±5°
55°
35°
max.
min.
Operation indicator Switches
Switches with Roller Lever Actuators
Basic Switches
Roller lever R38
General-purpose Models
WLCA2-LD-N
WLCA2-LE-N
60 max.
53±1.5
41.5±1.5
40±1.5
25.4
13.1
12.7
17.5×7 dia. *
Two, M3.5
R38
Four, 5.2 dia. holes
25.4
(125)
14.7
M5
Allen-head bolt
58.7±0.2
68.7
Three, M4
5
21.6
(4.9)
(15.1)
JIS B 0202 G½
30.2±0.2
40±0.7
29.2±1.5 Four, M6
42 max. Depth: 15 min
53.2±0.8
* Stainless sintered roller
Note: Unless otherwise indicated, a tolerance of ±0.4 mm applies to all dimensions.
Operating characteristics
Operating force
Release force
Pretravel
Overtravel
Movement Differential
50
Basic models
OF
RF
PT
OT
MD
max.
min.
min.
max.
13.34 N
1.18 N
15±5°
70°
12°
WL-N/WL
Sensor I/O Connector Switches
(For details about applicable cables, refer to Connecting Sensor I/O Connectors Cable and Socket on page 22.)
Switches with Roller Lever Actuators
Basic Switches
Roller lever R38
Pre-wired Connector type
Roller lever R38
Direct-wire Connector type
WLCA2-LD-M1J-N
WLCA2-LDK13-N
60 max.
53±1.5
41.5±1.5
40±1.5
25.4
13.1
12.7
17.5×7 dia. *
Two, M3.5
17.5×7 dia. *
Two, M3.5
R38
25.4
M5
Allen-head bolt
(125)
Four, 5.2 dia. holes
M5
Allen-head
bolt
14.7
(125)
25.4
58.7±0.2
68.7
58.7±0.2
(4.9)
(15.1)
5
12.5
30.2±0.2
M12×1
40±0.7
Four, M6
Depth: 15 min
SC-1M
300 +100
−50
Four, M6
Depth: 15 min.
29.2±1.2
42 max.
53.2±0.8
68.7
Three, M4
5
Three, M4
(15.1)
12.7
Four, 5.2 dia. holes
14.7
R38
(4.9)
60 max.
53±1.5
41.5±1.5
40±1.5
25.4
13.1
XS2H-D421
* Stainless sintered roller
30.2±0.2
40±0.7
29.2±1.2
42 max.
53.2±0.8
* Stainless sintered roller
Note: 1. Unless otherwise indicated, a tolerance of ±0.4 mm applies to all dimensions.
2. The models with operation indicators are shown in the above diagrams.
Operating characteristics
Operating force
Release force
Pretravel
Overtravel
Movement Differential
Basic models
OF
RF
PT
OT
MD
max.
min.
13.34 N
1.18 N
15±5°
70°
12°
min.
max.
High-sensitivity and High-precision Switches
Roller lever R38
Direct-wire Connector type
High-sensitivity
WLG2
High-precision
WLGCA2
53 ±1.5
41.5 ±1.5
40 ±1.5
13.1
17.5 dia. (length: 7) *
68.7
Three, M4
(length: 13)
5
68.7
(20)
+100
300 -50
±1.2
JIS B0202 G½
Effective thread:
4 threads min.
Four, M6
Depth: 15 min.
SC-1M
Four, M6
21.6 Depth: 15 min.
M12 × 1
* Stainless sintered roller
25.4
58.7 ±0.2
5
12.5
(4.9)
25.4
12.7
Four, 5.2 +0.2
0
dia. holes
Three, M4
(length: 13)
(15.1)
30.2 ±0.2
40 ±0.7
Four, M3.5
60 max.
53 ±1.5
41.5 ±1.5
40 ±1.5
13.1
M5 (length: 12)
Allen-head bolt
25.4
Four, 5.2 +0.2
0
dia. holes
58.7 ±0.2
38R
14.7
M5 (length: 12)
Allen-head bolt
14.7
17.5 dia. (length: 7) *
High-sensitivity
WLG2
High-precision
WLGCA2
25.4
12.7
Four, M3.5
38R
Roller lever R38
Pre-wired Connector type
60 max.
29.2
35
42 max.
6 dia.
53.2 ±0.8
(4.9)
(15.1)
30.2 ±0.2
40 ±0.7
XS2H-D421
M12 × 1
* Stainless sintered roller
21.6
±1.2
29.2
35
42 max.
53.2 ±0.8
Note: Unless otherwise indicated, a tolerance of ±0.4 mm applies to all dimensions.
Operating characteristics
Operating force
Release force
Pretravel
Overtravel
Movement Differential
OF
RF
PT
OT
MD
max.
min.
min.
max.
High-sensitivity
High-precision Models
9.81 N
0.98 N
+2°
10° −1°
65°
7°
13.34 N
1.47 N
+2°
5° 0°
40°
3°
51
WL-N/WL
Spatter-prevention Switches
Switches with Roller Lever Actuators
Basic Switches
Roller lever R38
Screw terminal type
Roller lever R38
Pre-wired Connector type
WLCA2-@S-N
17.5×7 dia. *
Two, M3.5
R38
WLCA2-@S-M1J-1-N
60 max.
53±1.5
41.5±1.5
40±1.5
25.4
13.1
12.7
60 max.
53±1.5
41.5±1.5
40±1.5
25.4
13.1
17.5×7 dia. *
Two, M3.5
R38
Four, 5.2 dia. holes
12.7
Four, 5.2 dia. holes
25.4
(125)
14.7
58.7±0.2
25.4
M5
Allen-head bolt
14.7
M5
Allen-head bolt
Fluorine
resin cap
Three, M4
(125)
58.7±0.2
68.7
5
Three, M4
Fluorine
resin cap
68.7
5
(4.9)
(15.1)
30.2±0.2
40±0.7
JIS B 0202 G½
21.6
29.2±1.2
42 max.
53.2±0.8
(4.9)
(15.1)
Four, M6
Depth: 15 min
Four, M6
Depth: 15 min
SC-1M
300 +100
−50
* Stainless sintered roller
XS2H-D421
29.2±1.2
30.2±0.2
40±0.7
42 max.
53.2±0.8
* Stainless sintered roller
Note: 1. Unless otherwise indicated, a tolerance of ±0.4 mm applies to all dimensions.
2. The models with operation indicators are shown in the above diagrams.
High-sensitivity/High-precision Switches
Roller lever R38
Screw terminal type
Roller lever R38
Pre-wired Connector type
WLG2-@S
WLGCA2-@S
WLG2-@S-M1J *
WLGCA2-@S-M1J *
* External dimensions are the same even for different core wires.
17.5 dia. (length: 7) *
Four, M3.5
head clamping screws
38R
25.4
Four, 5.2 +0.2
0
dia. holes
Fluororesin cap
14.7
17.5 dia. (length: 7) *
25.4
12.7
Two, M5 Allen-head nut
and arm set screw
38R
(125)
60 max.
54 ±1.5
13.1
Four, M3.5
head clamping screws
Two, M5 Allen-head nut
and arm set screw
60 max.
53 ±1.5
41.5 ±1.5
40 ±1.5
13.1
25.4
12.7
25.4
Four, 5.2 +0.2
0
dia. holes
14.7
Fluororesin cap
68.7
Three, M4
(length: 13)
58.7 ±0.2
68.7
58.7 ±0.2
Lamp cover
Lamp cover
5
5
Three, M4
(length: 13)
(4.9)
(15.1)
30.2 ±0.2
40 ±0.7
21.6
JIS B0202 G½
Effective thread:
4 threads min.
±1.2
29.2
(20)
Four, M6
Depth: 15 min.
Four, M6
Depth: 15 min.
35
42 max.
SC-1M
300 +100
−50
* Stainless steel roller
6 dia.
(4.9)
(15.1)
30.2 ±0.2
40 ±0.7
XS2H-D421
* Stainless steel roller
Note: Unless otherwise indicated, a tolerance of ±0.4 mm applies to all dimensions.
Operating characteristics
Operating force
Release force
Pretravel
Overtravel
Movement Differential
52
OF
RF
PT
OT
MD
max.
min.
min.
max.
Basic models
High-sensitivity
High-precision Models
13.34 N
1.18 N
15±5°
70°
12°
9.81 N
0.98 N
+2°
10° −1°
65°
7°
13.34 N
1.47 N
+2°
5° 0°
40°
3°
21.6
±1.2
29.2
35
42 max.
53.2 ±0.8
WL-N/WL
Switches with Plunger Actuators
Basic Switches
Sealed top-roller plunger
Screw terminal type
Sealed top-roller plunger
Pre-wired Connector type
WLD28-@S-N
WLD28-@S-M1J-1-N
14.3 dia.×5 *
PT
13.1
12.9
Rubber cap
(fluorine rubber)
14.3 dia.×5 *
Rubber cap
(fluorine rubber)
13.1
12.9
Two, M3.5
OP
Two, M3.5
OP
PT
Four, 5.2 dia. holes
Four, 5.2 dia. holes
58.7±0.2
58.7±0.2
68.7
68.7
Three, M4
Three, M4
5
5
(15.1)
21.6
JIS B 0202 G½
(4.9)
30.2±0.2
29.2±1.2
40±0.7
42 max.
Four, M6
Depth: 15 min
300
*Stainless sintered roller
Four, M6
Depth: 15 min
SC-1M
+100
−50
XS2H-D421
(15.1)
29.2±1.2
(4.9)
30.2±0.2
42 max.
40±0.7
*Stainless sintered roller
Note: 1. Unless otherwise indicated, a tolerance of ±0.4 mm applies to all dimensions.
2. The models with operation indicators are shown in the above diagrams.
Operating characteristics
Basic models
Operating force
Release force
Pretravel
Overtravel
Movement Differential
OF
RF
PT
OT
MD
max.
min.
Operating force
Pretravel
OF
PT
max.
min.
max.
16.67 N
4.41 N
1.7 mm max.
5.6 mm
1 mm
44±0.8 mm
39.5 mm
53
WL-N/WL
Long-life Switches
Switches with Roller Lever Actuators
Basic Switches
Roller lever R38
Screw terminal type
Roller lever R38
Direct-wire Connector type
WLMCA2-LD-N
60 max.
53±1.5
41.5±1.5
40±1.5
25.4
17.5 dia.×7 *
WLMCA2-LDK13-N
17.5 dia.×7 *
13.1
12.7
Two, M3.5
R38
Four, 5.2 dia. holes
25.4
14.7
Fluorine resin cap
Fluorine resin cap
68.7
58.7±0.2
68.7
Three, M4
Three, M4
5
12.5
21.6
(15.1)
Four, M6
Depth: 15 min
(4.9)
30.2±0.2
29.2±1.2
JIS B 0202 G½
*Stainless sintered roller
Roller lever R38
Pre-wired Connector type
60 max.
53±1.5
41.5±1.5
40±1.5
25.4
WLMCA2-LD-M1J-N
17.5 dia.×7 *
13.1
12.7
Two, M3.5
Four, 5.2 dia. holes
25.4
M5 Allen-head bolt
Fluorine resin cap
58.7±0.2
68.7
Three, M4
5
Four, M6
Depth: 15 min
SC-1M
300
+100
−50
XS2H-D421
(15.1)
29.2±1.2
(4.9)
42 max.
30.2±0.2
40±0.7
53.2±0.8
*Stainless sintered roller
Note: 1. Unless otherwise indicated, a tolerance of ±0.4 mm applies to all dimensions.
2. The models with operation indicators are shown in the above diagrams.
Operating characteristics
Operating force
Release force
Pretravel
Overtravel
Movement Differential
54
Basic models
OF
RF
PT
OT
MD
max.
min.
min.
max.
29.2±1.2
40±0.7
*Stainless sintered roller
13.34 N
1.18 N
15±5°
70°
12°
Four, M6
Depth: 15 min
M12×1
30.2±0.2
53.2±0.8
14.7
(15.1)
(4.9)
42 max.
40±0.7
R38
25.4
M5 Allen-head bolt
M5 Allen-head bolt
58.7±0.2
5
13.1
12.7
Two, M3.5
R38
Four, 5.2 dia. holes
14.7
60 max.
53±1.5
41.5±1.5
40±1.5
25.4
42 max.
53.2±0.8
WL-N/WL
Switches with Roller Lever Actuators
High-sensitivity and High-precision Switches
Roller lever R38
Screw terminal type
Roller lever R38
Direct-wire Connector type
60 max.
53 ±1.5
WLMG@-LD
38R
17.5 dia. (length: 7) *
Four, M3.5
(length: 26.5)
M5 (length: 12)
Allen-head bolt
WLMG@-LD@
41.5 ±1.5
40 ±1.5
13.1
17.5 dia. (length: 7) *
25.4
12.7
Four, M3.5
(length: 26.5)
38R
25.4
Four, 5.2 +0.2
0
dia. holes
14.7
60 max.
53 ±1.5
14.7
Rubber cap
58.7 ±0.2
58.7 ±0.2
Lamp cover
21.6
±1.2
(15.1)
30.2 ±0.2
40 ±0.7
(4.9)
29.2
* Stainless sintered roller
JIS B0202 G½
Effective thread:
4 threads min.
Four, M6
Depth: 15 min.
35
42 max.
WLMG@-LD@
17.5 dia. (length: 7) *
68.7
Lamp cover
SC-2FD
(15.1)
30.2 ±0.2
40 ±0.7
* Stainless sintered roller
Four, M6
21.6 Depth: 15 min.
±1.2
M12 x 1
JIS B0202 G½
Effective thread:
4 threads min.
29.2
35
42 max.
53.2 ±0.8
25.4
12.7
25.4
Four, 5.2 +0.2
0
dia. holes
14.7
25.4
60 max.
53 ±1.5
41.5 ±1.5
40 ±1.5
13.1
Four, M3.5
(length: 26.5)
M5 (length: 12)
Allen-head bolt
38R
M5 (length: 12)
Allen-head bolt
Four, 5.2 +0.2
0
dia. holes
Three, M4
(length: 13)
5
12.5
(4.9)
53.2 ±0.8
Roller lever R38
Pre-wired Connector type
25.4
12.7
Rubber cap
68.7
Three, M4
(length: 13)
5
41.5 ±1.5
40 ±1.5
13.1
Rubber cap
Three, M4
(length: 13)
58.7 ±0.2
68.7
Lamp cover
(20)
Four, M6
Depth: 15 min.
5
XS2H-D421
300 +100
-50
44.7
6 dia.
21.6
(15.1)
30.2 ±0.2
40 ±0.7
(4.9)
±1.2
29.2
35
42 max.
53.2 ±0.8
* Stainless sintered roller
Note: Unless otherwise indicated, a tolerance of ±0.4 mm applies to all dimensions.
Operating characteristics
Operating force
Release force
Pretravel
Overtravel
Movement Differential
OF
RF
PT
OT
MD
max.
min.
min.
max.
High-sensitivity
High-precision Models
9.81 N
0.98 N
+2°
10° −1°
65°
7°
13.34 N
1.47 N
+2°
5° 0°
40°
3°
55
WL-N/WL
Actuators (Levers Only)
Lever: Only rotating lever models are illustrated.
WL-1A100
Standard Lever
WL-1A115
Resin Roller
17.9
17.5 dia. × 7,
sintered stainless steel roller
7.3-dia.
mounting
holes
12.6
WL-1A105
Double Nuts
WL-1A103S
Spatter Prevention
17.9
17.5 dia. × 7,
sintered stainless steel roller
7.3-dia.
mounting
holes
12.6
Two, M5
Allenhead nut
11.4
and arm set screw
38
12.1
7.3-dia.
mounting 16
holes
M5
Allen-head bolt 11.4
16
17.9
7.3-dia.
mounting
holes
54.8
24.9±0.8
19.7±0.8
17.5 dia. × 7,
sintered stainless steel roller
7.3-dia.
mounting
holes
63
M5
Allen-head bolt 11.4
Adjustable lever:
stainless steel
WL-2A107
Double Nuts
24.9±0.8
19.7±0.8
17.5 dia. (length: 7)
resin roller
Adjustable lever:
stainless steel
Adjustable
range:
25 to 89
105.75
17.5 dia. × 7,
24.9±0.8
sintered stainless M5
steel roller
Allen-head 19.7±0.8
bolt
Adjustable lever:
stainless steel
7.3-dia.
mounting
holes
M5
Allen-head
bolt
12
16
105.75
12
16
12
16
M5
Allen-head bolt 11.4
17.5 dia. (length: 7)
resin roller
Adjustable lever:
stainless steel
24.9±0.8
M5
Allen-head 19.7±0.8
bolt
23
7.3-dia.
mounting
holes
7.3-dia.
mounting
holes
M5
Allen-head
bolt
79.8
Adjustable
range:
25 to 140
23
Adjustable
range:
25 to 89
105.75
7.3-dia.
mounting
holes
12.6
WL-2A108
Resin Roller
23
23
Adjustable
range:
25 to 89
17.9
50 66.8
16
WL-2A111
Resin Roller
M5
Allen-head bolt 11.4
17.5 dia. × 7,
sintered stainless steel roller
25.7
16.6
16
WL-2A100
23.6
WL-1A300
Lever Length: 63
17.5 dia. × 15,
sintered stainless steel roller
12.6
40.2±0.8
54.8
38
38 54.8
M5
Allen-head bolt 11.4
16
17.5 dia. (length: 30)
Nylon roller
16.9
WL-1A200
Lever Length: 50
Roller Width: 15
17.5 dia. (length: 7)
stainless steel roller
7.3-dia.
mounting
holes
38 54.8
16
7.3-dia.
mounting
holes
M5
Allen-head bolt 11.4
16
WL-1A118
Nylon Roller:
Roller Width: 30 mm
17 dia. (length: 6)
bearing roller
12.6
38 54.8
M5
Allen-head bolt 11.4
16
17.9
17.5 dia. (length: 7)
resin roller
7.3-dia.
mounting
holes
38 54.8
WL-1A400
Bearing Roller
155.75
Two, M5 Allen-head nut
and arm set screw
6.2
(15.8)
WL-2A122
WL-2A106
17.5 dia. × 7,
M5
sintered stainless
Allen-head
steel roller
bolt
Adjustable lever:
stainless steel
24.9±0.8
19.7±0.8
23
Adjustable
range:
25 to 140
7.3-dia.
mounting
holes
WL-2A130
9.1
24.9±0.8
19.7±0.8
50 dia. (length: 6)
Nylon roller
3
(21.8)
23
Adjustable
range:
25 to 89
(10)
R89.5
(10)
105.75
155.75
Adjustable
from 42 to 89
Three, 5.3 +0.2
0
dia. holes
7.3 dia.
mounting holes
(112)
M5
Allen-head
bolt
16
20
15.9
* Can be installed
on the rear side.
(15.8)
Note: Unless otherwise indicated, a tolerance of ±0.4 mm applies to all dimensions.
56
24.7±0.8
19.5±0.8
17.5 dia. × 7,
sintered stainless
steel roller
Adjustable lever:
stainless steel
7.3-dia.
mounting
holes
6.2
24.9±0.8
19.7±0.8
17.5 dia. × 7,
sintered stainless
steel roller
WL-2A104
7.3-dia.
mounting
holes
M5
Allen-head bolt
23
20
M5
Allen-head
bolt
12
16
23
WL-N/WL
Lever: Only rotating lever models are illustrated.
WL-2A110
WL-2A105
WL-1A106
WL-1A110
34.2
34.5
50 dia. (length: 15)
Nylon roller
24.2
49 dia. rubber roller
Material: NBR
24.4
50 dia. (length: 6)
Nylon roller
6
35 dia. (length: 6)
Nylon roller
20.1±0.8
20.1±0.8
R38
Adjustable
from 41 to
78.5
23
122
M5
Allen-head
bolt
7.3-dia.
mounting
holes
R38
23
Adjustable
from 41 to
89
M5
Allen-head
bolt
16
M5
Allen-head
bolt
7.3-dia.
mounting
holes
7.3 dia.
mounting
holes
16
11.5
11.5
M5
Allen-head
bolt
7.3-dia.
mounting
holes
16
16
WL-4A100
WL-4A201
9
9
3-dia. stainless
steel rod
7.3-dia. mounting
holes
M5
Allen-head
bolt
Adjustable
from
25 to 140
160
WL-3A100
3.2-dia.
stainless
steel rod
2-dia. stainless
steel for spring
13
Adjustable
from 270 to
290
Adjustable
from 350
to 380
7.3-dia.
mounting holes
M8
Allen-head
set screw
3.2-dia.
stainless steel rod
Adjustable
from 350
to 380
8
400±2
M5
Allen-head
bolt
19
WL-3A106
Double Nut
400±2
Actuator's
center of
rotation
M8
Allen-head
set screw
8
M5
Allen-head
bolt
11 65±2
7.5
6
11 65±2
7.5
6
11
7.3-dia.
mounting 12.8
holes
11
WL-3A108
WL-3A200
WL-3A203
2.3-dia.
operation rod
3.2-dia.
stainless steel rod
M5
13.4
Allen-head
bolt
25.5 max.
7.3-dia.
mounting
12.8
holes
9
8 dia.
Cap
Adjustable
up to 141
417.5±2
8
437.5±2
450±4
680±0.4
Adhesive
7.3-dia.
mounting 12.8
holes
M5
Allen-head
bolt
7.3-dia.
mounting
holes
7.5
25.5 max.
WL-2A129
15.8
Marking
(95)
11
7.5
6
13.4
WL-5A101
6.7
17.7
12.4
84
95.3
(108)
7.3 dia.
7.3 dia.
mounting
hole
10
15.9
20
M5
Allen-head
bolt
22.1
13
24.6 max.
WL-5A105
Two, 17.5 dia. × 7,
sintered stainless steel rollers
Two, 17.5 dia. × 7,
sintered stainless steel rollers
17.7 6.7
12.4
1.3
11
WL-5A100 has a plastic roller
17.7
12.4
90°
7.3 dia.
R38
54.8
M5 Allen-head
bolt
10
11.3
11
90°
90°
Three, 5.2
dia. holes
7.3-dia.
M5
mounting 7.5 Allen-head
holes
bolt
WL-5A103
1.3
(18.5)
M8
Allen-head
set screw
11
7.5
6
M5
13
Allen-head
bolt
24.6 max.
Two, 17.5 dia. × 7,
sintered stainless steel rollers
3
R8
19
12.5
dia.
max.
2.3 dia.
rod
(95)
11 65±2
7.5
6
4-dia. stainless
steel rod
7.3-dia.
mounting holes
M5
Allen-head
bolt
160±1.5
470±4
12.5 dia. max.
13.4
25.5 max.
WL-4A112
50
Adjustable
from 650
to 660
Two, M5
Allenhead
nut and arm
set screw
7.3 dia.
R38
54.8
M5 Allen-head
bolt
11
WL-5A102 has a plastic roller
R38
54.8
M5 Allen-head
bolt
11
WL-5A104 has a plastic roller
Note: 1. Unless otherwise indicated, a tolerance of ±0.4 mm applies to all dimensions.
2. When using the adjustable roller (rod) lever, make sure that the lever is facing downwards.
Use caution, as telegraphing (the Switch turns ON and OFF repeatedly due to inertia) may occur.
57
WL-N/WL
Model Replacement Table (Replacing WL Basic Models with WL-N Basic Models)
Manufacturing of the basic WL models is scheduled to be discontinued. Use the following table to find the corresponding WL-N-series models and
order them instead.
WL
WL-N
WL
WL-N
WLCA2
WLCA2-N
WLNJ
WL01CA2
WLCA2-N
WL01NJ
WLH2
WLCA2-N
WLNJ-30
WLNJ-30-N
WLD28-LD
WLD28-LD-N
WLCA2-N
WL01NJ-30
WLNJ-30-N
WLSD-LE
WLSD-LE-N
WLCA2-2
WLCA2-2-N
WLNJ-2
WLNJ-2-N
WLSD-LD
WLSD-LD-N
WL01CA2-2
WLCA2-2-N
WL01NJ-2
WLNJ-2-N
WLSD2-LE
WLSD2-LE-N
WLCA2-2N
WLCA2-2N-N
WLNJ-S2
WLNJ-S2-N
WLSD2-LD
WLSD2-LD-N
WL01CA2-2N
WLCA2-2N-N
WL01NJ-S2
WLNJ-S2-N
WLSD3-LE
WLSD3-LE-N
WLCA2-7
WLCA2-7-N
WLCA2-LE
WLCA2-LE-N
WLSD3-LD
WLSD3-LD-N
WL01CA2-7
WLCA2-7-N
WLCA2-LD
WLCA2-LD-N
WLNJ-LE
WLNJ-LE-N
WLCA2-8
WLCA2-8-N
WLH2-LE
WLCA2-LE-N
WLNJ-LD
WLNJ-LD-N
WL01CA2-8
WLCA2-8-N
WLH2-LD
WLCA2-LD-N
WLNJ-30LE
WLNJ-30LE-N
WLCA12
WLCA12-N
WLCA2-2LE
WLCA2-2LE-N
WLNJ-30LD
WLNJ-30LD-N
WL01CA12
WLCA12-N
WLCA2-2LD
WLCA2-2LD-N
WLNJ-2LE
WLNJ-2LE-N
WLH12
WLCA12-N
WLCA2-2NLE
WLCA2-2NLE-N
WLNJ-2LD
WLNJ-2LD-N
WL01H12
WLCA12-N
WLCA2-2NLD
WLCA2-2NLD-N
WLNJ-S2LE
WLNJ-S2LE-N
WLCA12-2-N
WLCA2-7LE
WLCA2-7LE-N
WLNJ-S2LD
WLNJ-S2LD-N
WL01CA12-2
WLCA12-2-N
WLCA2-7LD
WLCA2-7LD-N
WLCA2-LDK13
WLCA2-LDK13-N
WLCA12-2N
WLCA12-2N-N
WLCA2-8LE
WLCA2-8LE-N
WLCA2-55LDK13
WLCA2-55LDK13-N
WL01CA12-2N
WLCA12-2N-N
WLCA2-8LD
WLCA2-8LD-N
WLCA2-LDK43
WLCA2-LDK43-N
WLCL
WLCL-N
WLCA12-LE
WLCA12-LE-N
WLCA2-55LDK43
WLCA2-55LDK43-N
WL01CL
WLCL-N
WLCA12-LD
WLCA12-LD-N
WLD2-LDK13
WLD28-LDK13-N
WLHL
WLCL-2N-N
WLH12-LE
WLCA12-LE-N
WLD2-55LDK13
WLD28-55LDK13-N
WL01HL
WLCL-2N-N
WLH12-LD
WLCA12-LD-N
WLD2-LDK43
WLD28-LDK43-N
WLCL-2-N
WLCA12-2LE
WLCA12-2LE-N
WLD2-55LDK43
WLD28-55LDK43-N
WLCL-2N
WLCL-2N-N
WLCA12-2LD
WLCA12-2LD-N
WLH2-LDK13
WLCA2-LDK13-N
WL01CL-2N
WLCL-2N-N
WLCA12-2NLE
WLCA12-2NLE-N
WLH2-55LDK13
WLCA2-55LDK13-N
WLHAL4
WLCAL4-N
WLCA12-2NLD
WLCA12-2NLD-N
WLH2-LDK43
WLCA2-LDK43-N
WLHAL5
WLCAL5-N
WLCL-LE
WLCL-LE-N
WLH2-55LDK43
WLCA2-55LDK43-N
WLCA32-41
WLCA32-41-N
WLCL-LD
WLCL-LD-N
WLCA2-55LD-M1J
WLCA2-55LD-M1J-N
WL01CA32-41
WLCA32-41-N
WLHL-LE
WLCL-2NLE-N
WLCA2-LD-M1GJ
WLCA2-LD-M1GJ-N
WLCA32-42
WLCA32-42-N
WLHL-LD
WLCL-2NLD-N
WLCA2-55LD-M1GJ
WLCA2-55LD-M1GJ-N
WLCA32-43-N
WLCL-2LE
WLCL-2LE-N
WLCA2-55LD-M1JB
WLCA2-55LD-M1JB-N
WL01CA32-43
WLCA32-43-N
WLCL-2LD
WLCL-2LD-N
WLCA2-LD-DGJ03
WLCA2-LD-DGJ-N
WLCA32-44
WLCA32-44-N
WLCL-2NLE
WLCL-2NLE-N
WLCA2-55LD-DGJ03
WLCA2-55LD-DGJ-N
WLCL-2NLD-N
WLCA2-LD-DK1EJ03
WLCA2-LD-DK1EJ-N
WL01H2
WLCA12-2
WLCL-2
WLCA32-43
WLNJ-N
WLD3-LD
WLD38-LD-N
WLNJ-N
WLD28-LE
WLD28-LE-N
WLCA32-44-N
WLCL-2NLD
WLD
WLD18-N
WLHAL4-LE
WLCAL4-LE-N
WLCA2-55LD-DK1EJ03
WLCA2-55LD-DK1EJ-N
WL01D
WLD18-N
WLHAL4-LD
WLCAL4-LD-N
WLD2-LD-M1J
WLD28-LD-M1J-N
WLD2
WLD28-N
WLHAL5-LE
WLCAL5-LE-N
WLD2-55LD-M1J
WLD28-55LD-M1J-N
WL01D2
WLD28-N
WLHAL5-LD
WLCAL5-LD-N
WLD2-LD-M1GJ
WLD28-LD-M1GJ-N
WLCA32-41LE-N
WLD2-55LD-M1GJ
WLD28-55LD-M1GJ-N
WL01CA32-44
WLD3
WLD38-N
WLCA32-41LE
WL01D3
WLD38-N
WLCA32-41LD
WLCA32-41LD-N
WLD2-55LD-M1JB
WLD28-55LD-M1JB-N
WLD28
WLD28-N
WLCA32-42LE
WLCA32-42LE-N
WLD2-LD-DGJ03
WLD28-LD-DGJ-N
WLD28-N
WLCA32-43LE
WLCA32-43LE-N
WLD2-LD-DK1EJ03
WLD28-LD-DK1EJ-N
WLSD
WLSD-N
WLCA32-43LD
WLCA32-43LD-N
WLD2-55LD-DK1EJ03
WLD28-55LD-DK1EJ-N
WL01SD
WLSD-N
WLD-LE
WLD18-LE-N
WLH2-LD-M1J
WLCA2-LD-M1J-N
WLSD2
WLSD2-N
WLD-LD
WLD18-LD-N
WLH2-LD-M1GJ
WLCA2-LD-M1GJ-N
WL01SD2
WLSD2-N
WLD2-LE
WLD28-LE-N
WLH2-LD-DGJ03
WLCA2-LD-DGJ-N
WLSD3
WLSD3-N
WLD2-LD
WLD28-LD-N
WLCA2-55
WLCA2-55-N
WL01SD3
WLSD3-N
WLD3-LE
WLD38-LE-N
WLCA2-55LD
WLCA2-55LD-N
WL01D28
58
WL
WL-N
WL-N/WL
WL
WL-N
WL
WL-N
WL
WL-N
WLCA2-55LE
WLCA2-55LE-N
WLCA12-RP60
WLCA12-RP60-N
WLSD-TH
WLSD-TH-N
WLCA2-139
WLCA2-139-N
WLCA12-TH
WLCA12-TH-N
WLSD-TC
WLSD-TC-N
WLCA2-139LD2
WLCA2-139LD2-N
WLCA12-TC
WLCA12-TC-N
WLSD-RP
WLSD-RP-N
WLCA2-139LD3
WLCA2-139LD3-N
WLCA12-RP
WLCA12-RP-N
WLSD2-55
WLSD2-55-N
WLCA2-140
WLCA2-140-N
WLCA12-P1
WLCA12-P1-N
WLSD2-55LD
WLSD2-55LD-N
WLCA2-141
WLCA2-141-N
WLH12-TH
WLCA12-TH-N
WLSD2-139
WLSD2-139-N
WLCA2-141LD2
WLCA2-141LD2-N
WLH12-TC
WLCA12-TC-N
WLSD2-140
WLSD2-140-N
WLCA2-141LD3
WLCA2-141LD3-N
WLH12-RP
WLCA12-RP-N
WLSD2-RP60
WLSD2-RP60-N
WLCA2-RP60
WLCA2-RP60-N
WLH12-P1
WLCA12-P1-N
WLSD2-TH
WLSD2-TH-N
WLCA2-RP60LD2
WLCA2-RP60LD2-N
WLCA12-2TH
WLCA12-2TH-N
WLSD2-TC
WLSD2-TC-N
WLCA2-RP60LD3
WLCA2-RP60LD3-N
WLCA12-2TC
WLCA12-2TC-N
WLSD2-RP
WLSD2-RP-N
WLCA2-TH
WLCA2-TH-N
WLCA12-2NTH
WLCA12-2NTH-N
WLNJ-55
WLNJ-55-N
WLCA2-TC
WLCA2-TC-N
WLCA12-2NTC
WLCA12-2NTC-N
WLNJ-55LD
WLNJ-55LD-N
WLCA2-RP
WLCA2-RP-N
WLCL-55
WLCL-55-N
WLNJ-139
WLNJ-139-N
WLCA2-P1
WLCA2-P1-N
WLCL-55LD
WLCL-55LD-N
WLNJ-140
WLNJ-140-N
WLH2-55
WLCA2-55-N
WLCL-139
WLCL-139-N
WLNJ-RP60
WLNJ-RP60-N
WLH2-55LD
WLCA2-55LD-N
WLCL-140
WLCL-140-N
WLNJ-TH
WLNJ-TH-N
WLH2-55LE
WLCA2-55LE-N
WLCL-RP60
WLCL-RP60-N
WLNJ-TC
WLNJ-TC-N
WLH2-139
WLCA2-139-N
WLCL-TH
WLCL-TH-N
WLNJ-RP
WLNJ-RP-N
WLH2-140
WLCA2-140-N
WLCL-TC
WLCL-TC-N
WLNJ-255
WLNJ-255-N
WLH2-141
WLCA2-141-N
WLCL-RP
WLCL-RP-N
WLNJ-255LD
WLNJ-255LD-N
WLH2-141LD3
WLCA2-141LD3-N
WLCL-P1
WLCL-P1-N
WLNJ-2140
WLNJ-2140-N
WLH2-RP60
WLCA2-RP60-N
WLHL-TH
WLCL-2NTH-N
WLNJ-2RP60
WLNJ-2RP60-N
WLH2-RP60LD3
WLCA2-RP60LD3-N
WLHL-TC
WLCL-2NTC-N
WLNJ-2RP
WLNJ-2RP-N
WLH2-TH
WLCA2-TH-N
WLHL-RP
WLCL-2NRP-N
WLCA2-LEAS
WLCA2-LEAS-N
WLH2-TC
WLCA2-TC-N
WLHL-P1
WLCL-2NP1-N
WLH2-LEAS
WLCA2-LEAS-N
WLH2-RP
WLCA2-RP-N
WLGL-TH
WLGL-TH-N
WLCA2-LDAS
WLCA2-LDAS-N
WLH2-P1
WLCA2-P1-N
WLCL-2TH
WLCL-2TH-N
WLH2-LDAS
WLCA2-LDAS-N
WLCA2-255
WLCA2-255-N
WLCL-2TC
WLCL-2TC-N
WLCA2-LES
WLCA2-LES-N
WLCA2-255LD
WLCA2-255LD-N
WLCL-2RP
WLCL-2RP-N
WLH2-LES
WLCA2-LES-N
WLCA2-255LE
WLCA2-255LE-N
WLCL-2NTH
WLCL-2NTH-N
WLCA2-LDS
WLCA2-LDS-N
WLCA2-2139
WLCA2-2139-N
WLCL-2NTC
WLCL-2NTC-N
WLH2-LDS
WLCA2-LDS-N
WLCA2-2139LD2
WLCA2-2139LD2-N
WLD2-55
WLD28-55-N
WLD28-LES
WLD28-LES-N
WLCA2-2139LD3
WLCA2-2139LD3-N
WLD2-55LD
WLD28-55LD-N
WLD28-LDS
WLD28-LDS-N
WLCA2-2RP60
WLCA2-2RP60-N
WLD2-55LE
WLD28-55LE-N
WLMCA2-LD
WLMCA2-LD-N
WLCA2-2RP60LD2
WLCA2-2RP60LD2-N
WLD2-139
WLD28-139-N
WLMCA2-LDK13A
WLMCA2-LDK13A-N
WLCA2-2RP60LD3
WLCA2-2RP60LD3-N
WLD2-RP60
WLD28-RP60-N
WLMCA2-LDK13
WLMCA2-LDK13-N
WLCA2-2TH
WLCA2-2TH-N
WLD2-TH
WLD28-TH-N
WLMCA2-LDK43A
WLMCA2-LDK43A-N
WLCA2-2TC
WLCA2-2TC-N
WLD2-TC
WLD28-TC-N
WLMCA2-LDK43
WLMCA2-LDK43-N
WLCA2-2N55
WLCA2-2N55-N
WLD2-RP
WLD28-RP-N
WLMCA2-LD-M1J
WLMCA2-LD-M1J-N
WLCA2-2N55LD
WLCA2-2N55LD-N
WLD28-55
WLD28-55-N
WLMCA2-LD-DGJ03
WLMCA2-LD-DGJ-N
WLCA2-2N55LE
WLCA2-2N55LE-N
WLD28-55LD
WLD28-55LD-N
WLMH2-LD
WLMCA2-LD-N
WLCA2-2N139
WLCA2-2N139-N
WLD28-55LE
WLD28-55LE-N
WLMH2-LDK13A
WLMCA2-LDK13A-N
WLCA2-2N140
WLCA2-2N140-N
WLD28-139
WLD28-139-N
WLMH2-LDK13
WLMCA2-LDK13-N
WLCA2-2NTH
WLCA2-2NTH-N
WLD28-140
WLD28-140-N
WLMH2-LDK43A
WLMCA2-LDK43A-N
WLCA2-2NTC
WLCA2-2NTC-N
WLD28-RP60
WLD28-RP60-N
WLMH2-LDK43
WLMCA2-LDK43-N
WLCA12-55
WLCA12-55-N
WLD28-TH
WLD28-TH-N
WLMH2-LD-M1J
WLMCA2-LD-M1J-N
WLCA12-55LD
WLCA12-55LD-N
WLD28-RP
WLD28-RP-N
WLMH2-LD-DGJ03
WLMCA2-LD-DGJ-N
WLCA12-55LE
WLCA12-55LE-N
WLSD-55
WLSD-55-N
WLRCA2
WLRCA2-N
WLCA12-139
WLCA12-139-N
WLSD-55LD
WLSD-55LD-N
WLRH2
WLRCA2-N
WLCA12-140
WLCA12-140-N
WLSD-139
WLSD-139-N
WLRCA2-2
WLRCA2-2-N
WLCA12-141
WLCA12-141-N
WLSD-RP60
WLSD-RP60-N
WLRCA2-2N
WLRCA2-2N-N
59
WL-N/WL
WL
60
WL-N
WLRCA2
WLRCA2-N
WLRH2
WLRCA2-N
WLRCA2-2
WLRCA2-2-N
WLRCA2-2N
WLRCA2-2N-N
WLRCL
WLRCA2-N
WLRCA2-2
WLRCA2-2-N
WLRCA2-2N
WLRCA2-2N-N
WLRCA32
WLRCA32-N
WLRCA2-LDS
WLRCA2-LDS-N
WLRH2-LES
WLRCA2-LES-N
WLRH2-LDS
WLRCA2-LDS-N
WL-N/WL
Model Replacement Table (Replacing WL-N High-sensitivity and Highprecision Models with WL High-sensitivity and High-precision Models)
The WL-N high-sensitivity and high-precision models have been integrated into the WL Series. To use a WL-N high-sensitivity or high-precision
model, find the corresponding WL high-sensitivity or high-precision model in the following model replacement table, and order the switch with the
WL model number.
WL-N
WLG2-TH-N
WLG2-N
WLG2-LDS-N
WLG2-LD-N
WL
WL-N
WL
WL-N
WL01G2-TH-F
WLGCA2-LDS-N
WLGCA2-LDS
WLG2-55LD-M1JB-N
WLG2-TH-F
WLGCA2-LDS-M1J-1-N
WLGCA2-LDS-M1J-1
WLG2-55LD-M1GJ-N
WLG2-TH
WLGCA2-LDS-M1GJ-1-N
WLGCA2-LDS-M1GJ-1
WL01G2
WLGCA2-LD-N
WLG2
WL01GCA2-LD
WLGCA2-LD
WL01G2-LDS
WLGCA2-LD-M1J-N
WLGCA2-LD-M1J
WLG2-LDS
WLGCA2-LD-M1GJ-N
WLGCA2-LD-M1GJ 0.3M
WL01G2-LD
WLGCA2-LDK43-N
WLG2-LD
WLG2-55LDK43-N
WLG2-55LDK13CE
WLGCA2-LDK43
WLG2-55LD-DK1EJ-N WLG2-55LD-DK1EJ03
WLGCA2-LDK13
WLGCA2-LD-DGJ-N
WLGCA2-LD-DGJ03
WLG2-LD-M1JB-N
WLG2-LD-M1JB 0.3M
WLGCA2-55-N
WLGCA2-55
WLG2-141-N 5M
WLG2-LD-M1GJ-N
WLG2-LD-M1GJ 0.3M
WLGCA2-55LE-N
WLGCA2-55LE
WLG2-141-N 2M
WLG12-TH-N
WLGCA2-55LD-N
WLG2-LD-DGJ03
WLG2-55LDK13
WLG2-55LD-DTK1EJ-N
WLGCA2-LDK13-N
WLG2-LD-DGJ-N
WLG2-55LDK43
WL01GCA2-LDK43
WLG2-LD-M1J
WL01G2-LD-DGJ03
WLG2-55LD-M1GJ 0.3M
WL01G2-55LDK43
WL01G2-55LDK13
WLG2-55LDK13-N
WL01G2-LD-M1J
WLG2-LD-M1J-N
WL
WLG2-55LD-M1JB
WL01GCA2-55LD
WLGCA2-55LD
WLG2-55LD-DGJ-N
WLG2-141LD3-N 5M
WLG2-55LD-DTK1EJ03
WL01G2-55LD-DGJ03
WLG2-55LD-DGJ03
WLG2-141 5M
WLG2-141 2M
WL01G2-141LD3 5M
WLG2-141LD3 5M
WL01G12-TH
WLGCA2-55LD-M1J-N
WLGCA2-55LD-M1J 0.3M
WLG2-141LD2-N 5M
WLG2-141LD2 5M
WLG12-TH
WLGCA2-55LD-M1JB-N
WLGCA2-55LD-M1JB 0.3M
WLG2-140-N 5M
WLG2-140 5M
WL01G12
WLGCA2-55LD-M1GJ-N
WLGCA2-55LD-M1GJ 0.3M
WLG2-139-N 5M
WLG2-139 5M
WL01GCA2-55LDK43
WLG2-139-N 3M
WLG2-139 3M
WLR01G2
WLGCA2-55LDK43
WLG2-139LD3-N 5M
WLG2-139LD3 5M
WLRG2
WL01GCA2-55LDK13
WLG12-TC-N
WLG12-TC
WLGCA2-55LDK13-N
WLGCA2-55LDK13
WLG12-P1-N
WLG12-P1
WLGCA2-55LDK13CE
WLG12-LE-N
WLG12-LE
WLMGCA2-LD-M1J
WLGCA2-55LD-DGJ-N
WLGCA2-55LD-DGJ03
WLG12-LD-N
WLG12-LD
WLMGCA2-LDK43-N
WLMGCA2-LDK43
WLGCA2-139-N 5M
WLGCA2-139 5M
None
WLMGCA2-LDK13-N
WLMGCA2-LDK13
WLGCA2-139-N 3M
WLGCA2-139 3M
WL-2H4100-N
(FOR WLGL-N)
WLMGCA2-LDK13A-N
WLMGCA2-LDK13A
WLGCA2-139-N 2M
WLGCA2-139 2M
WL-2H2100-N
(FOR WLG12-N)
None
WLMG2-LD-N
WLMG2-LD
WLMG2-LD-M1J-N
WLMG2-LD-M1J
WLGCA2139LD3-N 5M
WLGCA21395LD3 S-FLEX 5M
WL-2H1100W-N
(FOR WLG2-141-N)
None
WLMG2-LDK43-N
WLMG2-LDK43
WLGCA2-139LD3-N 5M
WLGCA2-139LD3 5M
WLMG2-LDK13
WLGCA2-139LD2-N 5M
WLGCA2-139LD2 5M
WL-2H1100S-N
(FOR WLG2-S-N)
None
WLMG2-LDK13-N
WLMG2-LDK13A-N
WLMG2-LDK13A
WLG2-TC-N
WLG2-TC
None
WLMG2-LD-DGJ03
WLG2-RP
WL-2H1100-N
(FOR WLG2-N)
WLMG2-LD-DGJ-N
WLG2-RP-N
WLGL-TH-N
WLGL-TH
WLG12-N
WLRG2-N
WLG12
WLRG2-LDS-N
WLRG2-LDS
WLMGCA2-LD-N
WLMGCA2-LD
WLMGCA2-LD-M1J-N
WLGL-TC-N
WLGL-TC
WLGL-P1-N
WLGL-P1
WLGL-N
WL01GL
WLGL
WLGL-LE-N
WLGL-LE
WLGL-LD-N
WLGL-LD
WL01GCA2-TH
WLGCA2-TH-N
WLGCA2-2TH
WLGCA2-TC-N
WLGCA2-TC
WLGCA2-RP-N
WLGCA2-RP
WLGCA2-RP60-N 5M
WLGCA2-RP60
WLGCA2-RP60LD3-N 5M
WLGCA2-RP60LD3
WLGCA2-RP60LD2-N 5M
WLGCA2-RP60LD2
WLGCA2-TH
WLGCA2-N
WLGCA2-LES-N
WLGCA2-LE-N
WL01GCA2
WLGCA2
WLGCA2-LES
WL01GCA2-LE
WLGCA2-LE
WLGCA2-55LDK43-N
WLG2-RP60-N 5M
WLG2-RP60
WLG2-RP60-N 10M
WLG2-RP60 10M
WLG2-RP60LD3-N 5M
WLG2-RP60LD3
WLG2-RP60LD2-N 5M
WLG2-RP60LD2
WLG2-P1-N
WLG2-P1
WLG2-LES-N
WLG2-LES
WLG2-LE-N
WL01G2-LE
WLG2-LE
WLG2-LEAS-N
WLG2-LEAS
WLG2-LDK43-N
WLG2-LDK43
WLG2-LDK13-N
WL01G2-LDK13
WLG2-LDK13
WLG2-LD-DK1EJ-N
WLG2-LD-DK1EJ03
WLG2-LDAS-N
WLG2-LDAS
WLG2-55-N
WLG2-55LE-N
WLG2-55LD-N
WL01G2-55
WLG2-55
WLG2-55LE
WL01G2-55LD
WLG2-55LD
WLG2-55LD-M1TJ-N
WLG2-55LD-M1TJ
WLG2-55LD-M1TJB-N
WLG2-55LD-M1TJB
61
WL-N/WL
Safety Precautions
• Be sure to ground. Otherwise electric shock may result.
• Do not touch charged switch terminals while the switch has carry
current, Otherwise electric shock may result.
• Do not disassemble the limit switch or touch inside of it under
supplying power,
Otherwise electric shock may result.
• Do not disassemble the limit switch or touch inside of it under
supplying power, otherwise there is the possibility that electrical
shock occurs.
• Do not touch the wire or rod type actuator in order to prevent injury.
• Connect a fuse which has 1.5 to 2 times higher breaking current
than the switch rated current to the switch in series in order to
prevent the switch from short-circuit damage.
• On the occasion when using the switch with GB ratings, use a 10A
fuse that complies IEC60269, either type gG.
• The durability of switch is depends on the operating condition Be
sure to check the condition with actual using condition before
using, and use with the number of times of operating without a
performance problem.
• Otherwise, there is the possibility of spoiling the normal operation.
Do not drop the switch.
• Do not connect a Single Limit Switch to two power supplies that are
different in polarity or type. Risk of interference.
• Be sure to keep the load current less than the rated value.
Otherwise, there is the possibility that the switch may be damage
and/or burnout.
• Do not use the Switch by itself in atmospheres containing
flammable or explosive gases. Arcs and heating resulting from
switching may cause fire or explosion.
• Be sure to prevent the foreign materials such like a scrapped cable
intrusion in to the switch when wiring. Otherwise, there is the
possibility of spoiling the normal operation.
• Never wire to the wrong terminals.
• Do not store or use the switch with following place.
Where the temperature fluctuates greatly
Where the humidity is very high and condensation may occur.
Where the vibration is too much
Where receiving direct sunshine.
Where receiving salty wind.
• Do not disassemble and/or modify the switch at anytime.
Otherwise, there is the possibility of spoiling the normal operation.
• Do not apply the force such like deformation and/or degeneration
to the switch.
Precautions for Correct Use
Environment
• Take special care to use where there is fine powder, mud and/or
foreign materials stacking. And check the condition with actual
using condition before using. Then use without a performance
problem.
• Do not keep the Switch in locations with corrosive gas, such as
sulfuric gas (H2S or SO2), ammonium gas (NH3), nitric gas (HNO3),
or chlorine gas (Cl2), or high temperature and humidity.Otherwise,
contact failure or corrosion damage may result.
• Seal material may deteriorate if a Switch is used outdoor or where
subject to special cutting oils, solvents, or chemicals. Always
appraise performance under actual application conditions and set
suitable maintenance and replacement periods.
• Install Switches where they will not be directly subject to cutting
chips, dust, or dirt. The Actuator and Switch must also be protected
from the accumulation of cutting chips or sludge.
Not Suitable
62
Suitable
• Constantly subjecting a Switch to vibration or shock can result in
wear, which can lead to contact interference with contacts,
operation failure, reduced durability, and other problems.
Excessive vibration or shock can lead to false contact operation or
damage. Install Switches in locations not subject to shock and
vibration and in orientations that will not produce resonance.
• The Switches have physical contacts. Using them in environments
containing silicon gas will result in the formation of silicon oxide
(SiO2) due to arc energy. If silicon oxide accumulates on the
contacts, contact interference can occur. If silicon oil, silicon filling
agents, silicon cables, or other silicon products are present near
the Switch, suppress arcing with contact protective circuits (surge
suppressor) or remove the source of silicon gas.
Installing the Switch
• To install the Switch, make a mounting panel, as shown in the
following diagram, and tighten screws using the appropriate
tightening torque.
Front Mounting : Four, 5.2 +0.2
0 dia. holes
or M5 tapped holes
58.7±0.15
Rear Mounting : Four, 6.2 +0.2
0 dia. holes
30.2 ±0.15
Using Switches for Micro Loads
Contact faults may occur if a Switch for a general-load is used to
switch a micro load circuit. Use switches in the ranges shown in the
diagram below. However, even when using microload models within
the operating range shown here, if inrush current occurs when the
contact is opened or closed, it may increase contact wear and so
decrease durability. Therefore, insert a contact protection circuit
where necessary.
For the WL-N, the P level is at the min. operating load of 5 VDC and
1 mA resistive load.
Note: The P level indicates the standard malfunction level at a
reliability level of 60% (λ60).
(JISC5003) λ60 =0.1×10-6/operations indicates that the
estimated malfunction rate is less than 1/10,000,000
operations with a reliability level of 60%.
For the WL01G@, the N level is a reference value at the min.
operating load of 5 VDC and 1 mA resistive load. An estimated
malfunction rate of 1/2,000,000 operations at a reliability level of 60%
is indicated as a reference value.
Voltage (V)
Precautions for Safe Use
5 mW
800 mW
0.16 mA
30
26 mA
24
Operating range
for micro-load
models
Operating range
for standard
models
12
Unusable
range
5
1 mA
100 mA 160 mA
0
0.1
1
10
100
1,000
Current (mA)
WL-N/WL
Tightening Torque
• If screws are too loose they can lead to
an early malfunction of the Switch, so
ensure that all screws are tightened
using the appropriate tightening torque.
• In particular, when changing the
direction of the Head, make sure that all
screws are tightened again to the
appropriate tightening torque. Do not
allow foreign objects to fall into the
Switch.
In the case of prewired connector and direct
connector
(1)
How to handle
(3)
(6)
Built-in Switch
(5)
Type
Torque
Screw type
Head mounting screw
0.78 to 0.88
N•m
M3.5 screw
(2)
Cover mounting screw
1.18 to 1.37
N•m
M4 screw
(3)
Allen-head bolt
(for securing the roller lever)
4.90 to 5.88
N•m
M5 hexagon socket
head cap screw
(3)
Allen-head bolt
(for securing the adjustable
rod lever)
0.88 to 1.08
N•m
M8 hexagon socket set
screw
(4)
Terminal screw
0.59 to 0.78
N•m
M3.5 screw
(5)
Connector
1.77 to 2.16
N•m
G1/2orPg13.5orM20or
1/2-14NPT
Unit mounting screw
4.90 to 5.88
N•m
M5 screw
Back mounting screws
4.90 to 5.88
N•m
M6 screw
(1)
(6)
Wring
In the case of mounting screw
Basic Switches
• Use M3.5-nylon insulation covered crimp terminals (round type) for wiring.
Ex.) V1.25-M3.5(RAP1.25-3.5) (J.S.T. Mfg. Co.,Ltd.)
• Appropriate wire size is AWG16 (1.25 mm2).
• Do not supply electric power when wiring. Otherwise electric shock
may result.
• Do not pull out the wires with excessive force. It may cause of
coming off the wire.
• Use crimp terminals for wiring.
• In the case of indicator unit, to avoid interference
between lump unit and crimp terminals, wire
according to right wiring figure.
Attach the indicator unit spring to terminal screw
certainly, otherwise it's possible to be destroyed or
shorted.
• The ground terminal is only installed on models
with ground terminals.
High-sensitivity and High-precision Switches
• Use 1.25-mm2 lead wires and M4-insulation covered crimp
terminals for wiring.
Crimp Terminal External
Dimensions
Wiring Method
Switch Box Section
L
l
Changing direction of the head
• By removing two head screws or four head screws, mounting in
any of four orientations is possible. Be sure to change the plunger
for internal operations at the same time.
(4)
(2)
No.
• Holding the connector certainly when pulling connector.
• Don’t pull the cable holding it.
• Do not remove or replace the built-in switch. Risk of
malfunctioning.
Overtravel Markers
• All Switches with Roller Lever Actuators except for Switches with
Fork Lock Levers and Low-temperature Switches have a set
position marker plate.
• To allow the roller lever type actuator to travel properly, set the
roller lever according to the dog or cam stroke so that the
arrowhead of the lever is positioned within the overtravel markers
(pages 36, 37).
Connectors
• Tighten the connector with the appropriate torque to prevent
deformation.
• Use the OMRON type SC connector series, which is prepared
separately, suitable for outer diameter of cable and inner diameter
of seal rubber.
• Make sure to wrap the connector with the seal tape, except the
connector which has O-ring, to keep the sealability.
• To conform to CSA, use a CSA certified water tight treated conduit
hub.
• Even when the connector is assembled and set correctly, the end
of the cable and the inside of the Switch may come in contact. This
can lead to malfunction, leakage current, or fire, so be sure to
protect the end of the cable from splashes of oil or water and
corrosive gases.
Microload Applications
• The WL-N Basic Models contacts can be used both for standard
loads and microloads, but once a contact has been used to open
and close a load it can no longer be used for lower loads. Doing so
will damage the contact surface and reduce contact reliability.
• If an inrush current or other sudden load occurs during a switch
operation, the switch will begin to degrade severely which can
result in reduced durability. Use a contact protection circuit if
required.
Indicator
Indicator-equipped switch has contacts and indicator in parallel.
When contacts are open, leakage current flows through the indicator
circuit and may cause load's malfunction. Leakage current may cause
load malfunction (i.e., the load may remain ON). Make sure that the
load operating current is higher than the leakage current. For
countermeasures, refer to technical support on your OMRON
website.
Ground terminal
F
D dia.
dz dia. : 4.3
D dia. : 4.5
B
: 8.5
L
: 21.0
F
: 7.8
l
: 9.0 (mm)
B
dz dia.
NO terminal
NC terminal
• The ground terminal is only installed on models with ground terminals.
63
WL-N/WL
Terminal Plate
Basic Switches
By using the Terminal Plate (sold separately), as shown in the
following diagram, the Switch can be used as a single-polarity doublebreak switch.
Attach the Terminal Plate
so that the “COM” mark is
oriented as shown on the left.
Terminal Plate
Model
Terminal Plate Mounting Diagram
(with Two Terminal Screws Removed)
WL-N TERMINAL PLATE
High-sensitivity/High-precision Switches
By using a short circuit plate, as shown in the following diagram, the
Switch can be fabricated into a single-polarity double-break switch.
When ordering, specify WL Terminal Plate (product code: WL9662F).
9
2.5 +0.2
0
7.1
3R
9 ±0.2
COM
16 ±0.15 23 ±0.4
7
2R
3.5
2.1R
t = 0.6 Brass plate
4.2 +0.1
0
Using a WL@-2N Switch Mounted from the Side
If you replace a previous Switch with a WL@-2N-N Switch, a Mounting
Plate (sold separately) is available to maintain mounting compatibility.
If you use the Mounting Plate, the Switch mounting holes and actuator
position will be compatible. (The position of the dog remains
unchanged.)
64
58.7
Mounting Plate
23
30.2
WL@-2N
Mounting Plate
Replacing a Switch
with the WL@-2N-N
Plate mounting
bolts (2)
Set
contents
Plate (1)
Model
64
WLN-P001
Switch mounting
bolts (2)
WL-N/WL
Operation
• Carefully determine the position and shape of the dog or cam so
that the actuator will not abruptly snap back, thus causing shock.
In order to operate the Limit Switch at a comparatively high speed,
use a dog or cam that keeps the Limit Switch turned ON for a
sufficient time so that the relay or valve will be sufficiently
energized.
• The method of operation, the shape of the cam or dog, the
operating frequency, and the travel after operation have a large
influence on the durability and operating accuracy of the Limit
Switch. The cam or dog must be smooth in shape.
Incorrect
• Make sure that the actuator does not exceed the OT (overtravel)
range, otherwise the Limit Switch may malfunction. When
mounting the Limit Switch, be sure to adjust the Limit Switch
carefully while considering the whole movement of the actuator.
Operating
body
PT (Pretravel)
Install a stopper.
70% of
100% of
rated OT
rated OT
FP (Free position)
OP (Operating position)
OT (Overtravel)
TTP (Total travel position)
Correct
Optimum setting range
Distance to the
optimum setting range.
Snapped
back
Abruptly
actuated
Reference line
Incorrect
Correct
• The Limit Switch may soon malfunction if the OT is excessive.
Therefore, adjustments and careful consideration of the position of
the Limit Switch and the expected OT of the operating body are
necessary when mounting the Limit Switch.
Correct
Snapped
back Abruptly
actuated
Stopper
• Appropriate force must be imposed on the actuator by the cam or
dog in both rotary operation and linear operation.
If the dog touches the lever as shown below, the operating position
will not be stable.
Incorrect
Correct
Dog
Dog
• When using a pin-plunger actuator, make sure that the stroke of
the actuator and the movement of the dog are located along a
single straight line.
Incorrect
Correct
Operating
body
Operating
body
• Unbalanced force must not be imposed on the actuator. Otherwise,
wear and tear on the actuator may result.
Incorrect
Correct
Dog
Dog
Roller
Roller
• With a roller actuator, the dog must touch the actuator at a right
angle. The actuator or shaft may deform or break if the dog touches
the actuator (roller) at an oblique angle.
Incorrect
Dog
Others
• For long term (over a year) storage, check according to Operating
characteristics, Contact resistance and Dielectric strength at least.
And check with using condition.
• The durability of the Switch is greatly affected by operating
conditions.
Evaluate the Switch under actual working conditions before
permanent installation and use the Switch within a number of
switching operations that will not adversely affect the Switch’s
performance.
Correct
Dog
65
WL-N/WL
Using the Switches
Item
Changing the Installation Position of the
Actuator
By loosening the Allen-head bolt on the actuator lever, the position of the actuator can
be set anywhere within the 360°.
With Operation Indicator-equipped Switches, the actuator lever comes in contact with
the top of the indicator cover, so use caution
when rotating and setting the lever. When
the lever only moves forwards and backwards, it will not contact the lamp cover.
(This does not apply to Long-life Models.)
Changing the Orientation of the Head
By removing the head screws (two or four
screws), mounting in any of four orientations
is possible. Be sure to change the plunger
for internal operations at the same time.
The roller plunger can be set in either of two
positions at 90°.
Applicable models and Actuators
Details
Roller lever:
(WLCA2-N, WLCA2-2-N,
WLCA2-2N-N, WLG2,
WLCA2-7-N, WLCA2-8-N,
WLGCA2, WLMCA2-N,
WLMG2, WLMGCA2)
Adjustable Roller Lever:
(WLCA12-N, WLCA12-2-N,
WLCA12-2N-N, WLG12)
Adjustable Rod Lever:
(WLCL-N, WLCL-2-N,
WLCL-2N-N, WLGL,
WLCAL4-N, WLCAL5-N)
Roller lever:
(WLCA2-N, WLCA2-2-N,
WLCA2-2N-N, WLG2,
WLCA2-7-N, WLCA2-8-N,
WLGCA2, WLMCA2-N,
WLMG2, WLMGCA2)
Adjustable Roller Lever:
(WLCA12-N, WLCA12-2-N,
WLCA12-2N-N, WLG12)
Adjustable Rod Lever:
(WLCL-N, WLCL-2-N,
WLCL-2N-N, WLGL,
WLCAL4-N, WLCAL5-N)
Horizontal plunger:
(WLSD@-N)
Top-roller plunger:
(WLD2-N)
Sealed top-roller plunger:
(WLD28-N)
Fork lock lever:
(WLCA32-4@-N)
Loosen the Allen-head bolt, set
the actuator's position and then
tighten the bolt again.
Loosen the screws.
Head
Note: Excludes the -RP60-series and 141-series.
One-side Operation
Roller lever:
(WLCA2-N, WLCA2-2-N,
WLCA2-2N-N, WLCA2-7-N,
WLCA2-8-N, WLMCA2-N)
Adjustable Roller Lever:
(WLCA12-N, WLCA12-2-N,
WLCA12-2N-N)
Adjustable Rod Lever:
(WLCL-N, WLCL-2-N,
WLCL-2N-N, WLCAL4-N,
WLCAL5-N)
Changing the Operating Direction
By removing the Head on models which can
operate on one-side only, and then changing
the direction of the operational plunger, one
of three operating directions can be selected.
The tightening torque for the screws on the
Head is 0.78 to 0.88 N·m.
The output of the Switch will be
changed, regardless of which
direction the lever is pushed.
Operating
Operating
Operation in both
directions
The output of the Switch will
only be changed when the lever
is pushed in one direction.
Not operating Operating
Operating
Clockwise operation
Not operating
Counterclockwise
operation
One-side Operation for High-sensitivity and High-precision Switches
The output of the Switch will be
changed, regardless of which
direction the lever is pushed.
The output of the Switch will
only be changed when the lever
is pushed in one direction.
Operating Operating Not operating Operating Operating
Not operating
Roller lever:
(WLGCA2, WLMGCA2)
Operational
plunger
Operation in both
directions
66
Clockwise operation
Counterclockwise
operation
WL-N/WL
Item
Applicable models and Actuators
Installing the Roller on the Inside
By installing the roller lever in the opposite
direction, the roller can be installed on the inside. (Set so that operation can be completed within a 180° level range.)
Roller lever:
(WLCA2-N, WLCA2-2-N,
WLCA2-2N-N, WLG2,
WLCA2-7-N, WLCA2-8-N,
WLGCA2, WLMCA2-N,
WLMG2, WLMGCA2)
Fork Lock Lever:
(WLCA32-4@-N)
Details
Loosen the
Allen-head bolt.
Adjustment
range radius:
25 to 140 mm
Adjustable Roller Lever:
(WLCA12-N, WLCA12-2-N,
Adjusting the Length of the Rod or Lever
WLCA12-2N-N, WLG12)
The length of the rod or lever can be adjustAdjustable Rod Lever:
ed by loosening the Allen-head bolt.
(WLCL-N, WLCL-2-N,
WLCL-2N-N, WLGL, WLCAL4-N)
Loosen this
Allen-head bolt
and adjust the
length of the
lever.
Adjustment
range radius:
25 to 89 mm
Adjustable Roller Levers:
Selecting the Roller Position
There are four types of Switches with Fork
Lock Levers for use depending on the roller
position.
Fork Lock Lever:
(WLCA32-4@-N)
Loosen this
Allen-head bolt
and adjust the
length of the rod.
Adjustable Rod Levers:
WLCA32-41-N
WLCA32-43-N
WLCA32-42-N
WLCA32-44-N
An explanation of the operation of fork lock levers is provided after this
table.
Operation of Fork Lock Levers
A Switch with a Fork Lock Lever is constructed so that the dog pushes the lever to invert the output and this inverted state is maintained even after
the dog moves on.
If the dog then pushes the lever from the opposite direction, the lever will return to its original position.
Example
NC terminal: ON
NO terminal: ON
NO terminal: ON
67
WL-N/WL
Limit Switch Connectors
Connectors (SC Series)
Cabtire cables and flexible tubes with various diameters are used to
connect machine tools and controllers with Limit Switches. To ensure
the watertightness of the edges of the conduits, use an SC Connector
that is suitable for the external diameter of cable and model of Limit
Switch.
Ordering Information
Connector for Cabtire Cable
Conduit
Applicable cable
Cabtire cable (generalpurpose)
JIS B 0202 G½
Cabtire cable (anti-corrosive)
½-14NPT
Cabtire cable
Inner diameter (D)
of seal rubber
7 mm
9 mm
12.5 mm
14 mm
11 mm
7 mm
9 mm
12.5 mm
14 mm
11 mm
7 mm
9 mm
12.5 mm
14 mm
11 mm
External diameter of cable
Min.
Max.
5.5 mm
7.5 mm
7.5 mm
9.5 mm
11 mm
13 mm
12 mm
14 mm
9 mm
11 mm
5.5 mm
7.5 mm
7.5 mm
9.5 mm
11 mm
13 mm
12 mm
14 mm
9 mm
11 mm
5.5 mm
7.5 mm
7.5 mm
9.5 mm
11 mm
13 mm
12 mm
14 mm
9 mm
11 mm
Model
SC-1M
SC-2M
SC-3M
SC-4M
SC-5M
SC-21
SC-22
SC-23
SC-24
SC-25
SC-1PT
SC-2PT
SC-3PT
SC-4PT
SC-5PT
Applicable model
WL-N, WL, D4A-@N, D4B-@N,
ZE, ZV, ZV2, XE, XV, XV2
D4A-@N
Note: Please use sealing tape with SC Connectors. SC-1M to SC-5M, however, are provided with an O-ring (NBR) and therefore sealing tape is
not necessary to ensure a proper seal.
Simple Connectors (Not Suitable for Locations Subject to Oil or Water)
Conduit
Applicable cable
JIS B 0202 G½
Pg13.5
JIS B 0202 G½
Cabtire cable
Inner diameter (D)
of seal rubber
External diameter of cable
Min.
Max.
Model
10.6 mm
8.5 mm
10.5 mm
SC-P2
9.6 mm
7.5 mm
9.5 mm
SC-P3
9 mm
7.5 mm
9 mm
SC-6
Applicable model
WL-N, WL, D4A-@N, D4B-@N,
ZE, ZV, ZV2, XE, XV, XV2
WL@-G-N
WL-N, WL, D4A-@N, D4N *,
D4N-@R *, D4B-@N, ZE, ZV,
ZV2, XE, XV, XV2
Note: Simple connector are made of resin. If more sealing capability is required, use one of SC-1M to SC-5M, which have metal casings.
Models marked with an asterisk (*) however, can only be used with resin connectors.
68
WL-N/WL
Dimensions and Structure
(Unit: mm)
Connectors for Cabtire Cable
As for models without an O-ring, please use sealing tape with SC Connectors.
Metal Models without O-ring
G½
SC-21 to 25
JIS B 0202 G½
14.6 dia.
*E
15
4.8
9
24
14 dia.
27.7
29.3
Ball head lock nut
(brass and nickel plating)
Washer (stainless steel)
Sealing rubber
(nitrile rubber)
Connector
(brass and nickel plating)
*D
(34)
Metal Models with O-ring
G½
SC-1M to 5M
14.6 dia.
*E
15
JIS B 0202 G½
5 9
29.3
27
14 dia.
Ball head lock nut
(zinc die-cast and zinc plating)
Washer (stainless steel)
*D
30
Sealing rubber (nitrile rubber)
(34)
Metal Models without O-ring
½-14NPT
(U.S.-standard screws)
SC-1PT to 5PT
14.6 dia.
14 dia.
15
5
Sealing rubber
(nitrile rubber)
Connector
(zinc die-cast and
zinc plating)
14
29.3
½-14NPT
24
14 dia.
Ball head lock nut
(zinc die-cast and zinc plating)
Washer (stainless steel)
Sealing rubber (nitrile rubber)
Connector
(zinc die-cast and
zinc plating)
*D
27.7
(39)
Note: Dimensions not shown in the above diagrams have a variation of ±0.4 mm.
Simple Connectors (Not Suitable for Locations Subject to Oil or Water)
Resin Models
G½
SC-P2
15
22
5
18 dia.
12.6 dia.
25.4
Resin Models
Pg13.5
SC-P3
15.5
5
21
Pg13.5
Hexagonal nut
(polyacetal resin)
4.5
Hexagonal nut
(polyacetal resin)
Conduit washer
(ferrous metal and
zinc plating)
Ring (chloroprene rubber)
18 dia.
10.6 dia.
1
Conduit washer
(ferrous metal and
zinc plating)
18 dia.
9.6 dia.
22.5
12
9
(30.6)
10
9
4.5
Ring (chloroprene rubber)
18 dia.
12 dia.
23.5
Resin Models
G½
SC-6
JIS B 0202
1
G½
12
5
9
Ball head lock nut
(polyacetal resin)
Washer
(ferrous metal and
zinc plating)
Sealing rubber (nitrile rubber)
Connector
(polyacetal resin)
*D
26
G½
M20 × 1.5
Note: Dimensions not shown in the above diagrams have a variation of ±0.4 mm.
* Diameter of Part Marked with Asterisk
Model
SC-21, -1M, -1PT
SC-22, -2M, -2PT
SC-23, -3M, -3PT
SC-24, -4M, 4PT
SC-25, -5M, -5PT
SC-6
Inner diameter (D)
of sealed rubber
7 mm
9 mm
12.5 mm
14 mm
11 mm
9 mm
Internal diameter
(E) of washer
10.4 mm
13.2 mm
14.6 mm
14.6 mm
13.2 mm
10 mm
Applicable cable
5.5 to 7.5-mm dia.
7.5 to 9.5-mm dia.
11 to 13-mm dia.
12 to 14-mm dia.
9 to 11-mm dia.
7.5 to 9-mm dia.
69
MEMO
70
Terms and Conditions Agreement
Read and understand this catalog.
Please read and understand this catalog before purchasing the products. Please consult your OMRON representative if you have
any questions or comments.
Warranties.
(a) Exclusive Warranty. Omron’s exclusive warranty is that the Products will be free from defects in materials and workmanship
for a period of twelve months from the date of sale by Omron (or such other period expressed in writing
by Omron). Omron disclaims all other warranties, express or implied.
(b) Limitations. OMRON MAKES NO WARRANTY OR REPRESENTATION, EXPRESS OR IMPLIED, ABOUT
NON-INFRINGEMENT, MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE OF THE
PRODUCTS. BUYER ACKNOWLEDGES THAT IT ALONE HAS DETERMINED THAT THE PRODUCTS WILL
SUITABLY MEET THE REQUIREMENTS OF THEIR INTENDED USE.
Omron further disclaims all warranties and responsibility of any type for claims or expenses based on infringement by the Products
or otherwise of any intellectual property right. (c) Buyer Remedy. Omron’s sole obligation hereunder shall be, at Omron’s election,
to (i) replace (in the form originally shipped with Buyer responsible for labor charges for removal or replacement thereof) the
non-complying Product, (ii) repair the non-complying Product, or (iii) repay or credit Buyer an amount equal to the purchase price
of the non-complying Product; provided that in no event shall Omron be responsible for warranty, repair, indemnity or any other
claims or expenses regarding the Products unless Omron’s analysis confirms that the Products were properly handled, stored,
installed and maintained and not subject to contamination, abuse, misuse or inappropriate modification. Return of any Products by
Buyer must be approved in writing by Omron before shipment. Omron Companies shall not be liable for the suitability or
unsuitability or the results from the use of Products in combination with any electrical or electronic components, circuits, system
assemblies or any other materials or substances or environments. Any advice, recommendations or information given orally or in
writing, are not to be construed as an amendment or addition to the above warranty.
See http://www.omron.com/global/ or contact your Omron representative for published information.
Limitation on Liability; Etc.
OMRON COMPANIES SHALL NOT BE LIABLE FOR SPECIAL, INDIRECT, INCIDENTAL, OR CONSEQUENTIAL DAMAGES,
LOSS OF PROFITS OR PRODUCTION OR COMMERCIAL LOSS IN ANY WAY CONNECTED WITH THE PRODUCTS,
WHETHER SUCH CLAIM IS BASED IN CONTRACT, WARRANTY, NEGLIGENCE OR STRICT LIABILITY.
Further, in no event shall liability of Omron Companies exceed the individual price of the Product on which liability is asserted.
Suitability of Use.
Omron Companies shall not be responsible for conformity with any standards, codes or regulations which apply to the
combination of the Product in the Buyer’s application or use of the Product. At Buyer’s request, Omron will provide applicable
third party certification documents identifying ratings and limitations of use which apply to the Product. This information by itself is
not sufficient for a complete determination of the suitability of the Product in combination with the end product, machine, system,
or other application or use. Buyer shall be solely responsible for determining appropriateness of the particular Product with
respect to Buyer’s application, product or system. Buyer shall take application responsibility in all cases.
NEVER USE THE PRODUCT FOR AN APPLICATION INVOLVING SERIOUS RISK TO LIFE OR PROPERTY OR IN LARGE
QUANTITIES WITHOUT ENSURING THAT THE SYSTEM AS A WHOLE HAS BEEN DESIGNED TO ADDRESS THE RISKS,
AND THAT THE OMRON PRODUCT(S) IS PROPERLY RATED AND INSTALLED FOR THE INTENDED USE WITHIN THE
OVERALL EQUIPMENT OR SYSTEM.
Programmable Products.
Omron Companies shall not be responsible for the user’s programming of a programmable Product, or any consequence thereof.
Performance Data.
Data presented in Omron Company websites, catalogs and other materials is provided as a guide for the user in determining
suitability and does not constitute a warranty. It may represent the result of Omron’s test conditions, and the user must correlate it
to actual application requirements. Actual performance is subject to the Omron’s Warranty and Limitations of Liability.
Change in Specifications.
Product specifications and accessories may be changed at any time based on improvements and other reasons. It is our practice
to change part numbers when published ratings or features are changed, or when significant construction changes are made.
However, some specifications of the Product may be changed without any notice. When in doubt, special part numbers may be
assigned to fix or establish key specifications for your application. Please consult with your Omron’s representative at any time to
confirm actual specifications of purchased Product.
Errors and Omissions.
Information presented by Omron Companies has been checked and is believed to be accurate; however, no responsibility is
assumed for clerical, typographical or proofreading errors or omissions.
OMRON AUTOMATION AMERICAS HEADQUARTERS • Chicago, IL USA • 847.843.7900 • 800.556.6766 • www.omron247.com
OMRON CANADA, INC. • HEAD OFFICE
Toronto, ON, Canada • 416.286.6465 • 866.986.6766 • www.omron247.com
OMRON ARGENTINA • SALES OFFICE
Cono Sur • 54.11.4783.5300
OMRON ELECTRONICS DE MEXICO • HEAD OFFICE
México DF • 52.55.59.01.43.00 • 01-800-226-6766 • mela@omron.com
OMRON CHILE • SALES OFFICE
Santiago • 56.9.9917.3920
OMRON ELECTRONICS DE MEXICO • SALES OFFICE
Apodaca, N.L. • 52.81.11.56.99.20 • 01-800-226-6766 • mela@omron.com
OTHER OMRON LATIN AMERICA SALES
54.11.4783.5300
OMRON ELETRÔNICA DO BRASIL LTDA • HEAD OFFICE
São Paulo, SP, Brasil • 55.11.2101.6300 • www.omron.com.br
OMRON EUROPE B.V. • Wegalaan 67-69, NL-2132 JD, Hoofddorp, The Netherlands. • +31 (0) 23 568 13 00 • www.industrial.omron.eu
Controllers & I/O
• Machine Automation Controllers (MAC) • Motion Controllers
• Programmable Logic Controllers (PLC) • Temperature Controllers • Remote I/O
Authorized Distributor:
Robotics
• Industrial Robots • Mobile Robots
Operator Interfaces
• Human Machine Interface (HMI)
Motion & Drives
• Machine Automation Controllers (MAC) • Motion Controllers • Servo Systems
• Frequency Inverters
Vision, Measurement & Identification
• Vision Sensors & Systems • Measurement Sensors • Auto Identification Systems
Sensing
• Photoelectric Sensors • Fiber-Optic Sensors • Proximity Sensors
• Rotary Encoders • Ultrasonic Sensors
Safety
• Safety Light Curtains • Safety Laser Scanners • Programmable Safety Systems
• Safety Mats and Edges • Safety Door Switches • Emergency Stop Devices
• Safety Switches & Operator Controls • Safety Monitoring/Force-guided Relays
Control Components
• Power Supplies • Timers • Counters • Programmable Relays
• Digital Panel Meters • Monitoring Products
Switches & Relays
• Limit Switches • Pushbutton Switches • Electromechanical Relays
• Solid State Relays
Software
• Programming & Configuration • Runtime
C151-E1-01
03/17
Note: Specifications are subject to change.
© 2017 Omron. All Rights Reserved.
Printed on recycled paper.
Printed in U.S.A.