WLCA122TSN

WLCA122TSN

  • 厂商:

    OMRON(欧姆龙)

  • 封装:

    -

  • 描述:

    检测开关 单刀双掷 DC30V AC125V

  • 数据手册
  • 价格&库存
WLCA122TSN 数据手册
Two-circuit Limit Switch WL-N/WL Two-circuit limit switches that can be selected to match the operating environment and application • Wide variety of head shapes, including Roller Lever, Plunger, Flexible Rod, and Fork Lock Lever Switches. • You can select the optimum actuator shape for the workpiece shape and movement from a variety of actuators. • In addition to general detection, we also have environment resistant models for harsh environments, sputter resistant models for welding processes, and long-life models for high-frequency use. For the most recent information on models that have been certified for safety standards, refer to your OMRON website. Be sure to read Safety Precautions on page 62 to 67 and Safety Precautions for All Limit Switches. Features General-purpose Switches Features Common A Wide Range of Models DPDB Operation You can select the optimum product for the workpiece shape and movement from a variety of actuators, including Roller Lever, Plunger, Flexible Rod, and Fork Lock Lever Switches. The two-circuit double-break structure ensures circuit braking. • Basic/Retention type Switches (WL-N) Environment-resistant Switches Za (NO)14 13(NO) (NC)11 12(NC) 11 14 12 13 Six environment resistant models are available Airtight Switches, Hermetic Switches, Heat-resistant Switches, Lowtemperature Switches, Corrosion-proof Switches, and Weather-proof Switches are available. You can select the model based on the onsite environment. Load Load • High-sensitivity/High-precision Switches (WL) Spatter-prevention Switches Za (NO)4 3(NO) (NC)1 2(NC) 1 4 2 3 Ideal for Welding Sites Uses stainless steel and plastic materials that prevent the adhesion of spatter. They can be used to reduce problems caused by zinc power generated during welding. Long-life Switches Long-life Models for High-frequency Applications A mechanical durability of over 30 million cycles is achieved by improving slidability and the wear resistance of the head. Load Load Degree of Protection; IP67 Models with Connectors to Reduce Wiring A neon lamp or LED indicates the operating status. This makes startup checks and maintenance easy. Sensor I/O Connector Models to Match Wiring Specifications Direct-wire types and pre-wired types are available for easy replacement of limit switches. 1 WL-N/WL Product Configuration Generalpurpose Standard *1 Operation indicators *1 Operating Characteristic Roller Lever Actuators Basic Switches High-sensitivity Switches High-precision Switches WLC@-N WLG@ WLGCA2 Plunger Actuators Basic Switches WLD@-N WLSD@-N Flexible Rod Actuators Basic Switches WLNJ-@-N Fork Lock Lever Actuator Retention type Switches WLCA32-4@-N Indicator-equipped Switches:Neon lamps Basic Switches High-sensitivity Switches High-precision Switches WLC@-LE-N WLG@-LE WLGCA2-LE Indicator-equipped Switches: Light emitting diodes (LED) Basic Switches High-sensitivity Switches High-precision Switches WLC@-LD-N WLG@-LD WLGCA2-LD Indicator-equipped Switches: Neon lamps Basic Switches WLD@-LE-N WLSD@-LE-N Indicator-equipped Switches: Light emitting diodes (LED) Basic Switches WLD@-LD-N WLSD@-LD-N Indicator-equipped Switches: Neon lamps Basic Switches WLNJ-@LE-N Indicator-equipped Switches: Light emitting diodes (LED) Basic Switches WLNJ-@LD-N Indicator-equipped Switches: Neon lamps Retention type Switches WLCA32-4@LE-N Indicator-equipped Switches: Light emitting diodes (LED) Retention type Switches WLCA32-4@LD-N Direct-wired Types Basic Switches High-sensitivity Switches High-precision Switches WLCA2-LDK@-N WLG2-LDK@ WLGCA2-LDK@ Pre-wired Types Basic Switches WLCA2-@LD-M1@@-N WLCA2-@LD-D@J-N High-sensitivity Switches WLG2-@LD-M1@@ WLG2-@LD-D@J@ High-precision Switches WLGCA2-@LD-M1@@ WLGCA2-@LD-D@J@ Basic Switches Basic Switches WLD28-@LDK@-N WLD28-@LD-M1@@-N WLD28-@LD-D@J-N Roller Lever Actuators Plunger Actuators Flexible Rod Actuators Fork Lock Lever Actuator Sensor I/O connectors Roller Lever Actuators Plunger Actuators *1. The standard wiring specification is the Screw terminal type. *2. Wiring specification: Smart-click type is also available. 2 Typical models Head/Actuator Direct-wired Types Pre-wired Types WL-N/WL Head/Actuator Environmentresistant *1 Airtight seal *4 Hermetic seal *4 Heat-resistant Low-temperature Corrosion-proof Weather-proof Spatter-prevention *1 *3 Long-life *1 *2 *3 *1. *2. *3. *4. Operating Characteristic Typical models Roller Lever Actuators Basic Switches High-sensitivity Switches High-precision Switches WLC@-55-N WLG@-55 WLGCA2-55 Plunger Actuators Basic Switches WLD@-55-N, WLSD@-55-N Flexible Rod Actuators Basic Switches WLNJ-@55-N Roller Lever Actuators Basic Switches WLC@-139-N High-sensitivity Switches High-precision Switches WLG@-139 WLGCA2-139 Plunger Actuators Basic Switches WLD@-139-N, WLSD@-139-N Flexible Rod Actuators Basic Switches WLNJ-@139-N Roller Lever Actuators Basic Switches High-sensitivity Switches High-precision Switches WLC@-TH-N WLG@-TH WLGCA2-TH Plunger Actuators Basic Switches WLD@-TH-N, WLSD@-TH-N Flexible Rod Actuators Basic Switches WLNJ-@TH-N Roller Lever Actuators Basic Switches High-sensitivity Switches High-precision Switches WLC@-TC-N WLG@-TC WLGCA2-TC Plunger Actuators Basic Switches WLD@-TC-N, WLSD@-TC-N Flexible Rod Actuators Basic Switches WLNJ-@TC-N Roller Lever Actuators Basic Switches High-sensitivity Switches WLC@-RP-N WLG@-RP High-precision Switches WLGCA2-RP Plunger Actuators Basic Switches WLD@-RP-N, WLSD@-RP-N Flexible Rod Actuators Basic Switches WLNJ-@RP-N Roller Lever Actuators Basic Switches High-sensitivity Switches WLC@-P1-N WLG@-P1 Roller Lever Actuators Basic Switches High-sensitivity Switches High-precision Switches WLCA2-@S-N WLG2-@S WLGCA2-@S Plunger Actuators Basic Switches WLD28-@S-N Roller Lever Actuators *4 Basic Switches High-sensitivity Switches High-precision Switches WLMCA2-@-N WLMG2-@ WLMGCA2-@ The standard wiring specification is the Screw terminal type. Wiring specification: Direct-wire Connector type is also available. Contact your OMRON sales representative for further information. Wiring specification: Pre-wired Connector type is also available. Contact your OMRON sales representative for further information. A type with an operation indicator light is also available. For details, see Ordering Information. 3 WL-N/WL Selection WL-N/WL Actuator Types and Selection Head Appearance Classification Operating force (OF) Repeat accuracy *1 ★★★ Roller Lever Medium ★★ *2 Shock and vibration resistance *1 Description ★★★ • Can be used over a wide range, from positioning to workpiece detection. • Easy to use because the stroke in the direction of revolution can be set to an angle from 45° to 90° (varies by model), and the lever can be set to any angle over 360°. • High-sensitivity Switches with minimal movement before activation (example: WLG2) and High-precision Switches with high repeatability (example: WLGCA2) are available. Roller Lever Models Adjustable Roller Lever Adjustable Rod Lever Medium ★★ ★★ • Adjustable length between dog and lever. (Consideration must be given to telegraphing.) • Can be used over a wide range, from positioning to workpiece detection. • High-sensitivity Switches with minimal movement before activation (example: WLG12) are also available. • Suitable for detection of a dog or workpiece with a large amount of play. (Consideration must be given to telegraphing.) • Also good for detection of irregularly shaped workpieces. • Lightest activation (WLCL-N) among rotating-type limit switches. • Rod length is adjustable. • High-sensitivity Switches with minimal movement before activation (example: WLG2) are also available. Medium ★★ ★★ Plunger Large ★★★ ★★★ • High repeatability, good for positioning detection. • The workpiece movement direction and plunger movement direction must be matched so that an unbalanced load is not applied to the plunger. Roller plunger Large ★★★ ★★★ • A wide range of operation is possible by attaching an auxiliary actuator to a cam, dog, cylinder, or other part. • High repeatability, good for positioning detection. ★★★ • The tip of the plunger is made of a steel ball, which can be operated in any direction with no limitations. • The ball plunger is convenient when the mounting side is not aligned with the movement direction of the dog or the Limit Switch is actuated by two dogs in X and Y directions. Plunger Models Ball plunger Coil spring Large Small ★★ ★ ★ • Operation from any direction over 360° is possible, excluding the axial direction. • Lowest activation force of the limit switches. Effective for detection of non-uniform directions and shapes. • Large tolerance for workpiece play because the actuator absorbs movement after activation. ★ • The resin rod minimizes damage to the workpiece. • Operation from any direction over 360° is possible, excluding the axial direction. • Lowest activation force of the limit switches. Effective for detection of non-uniform directions and shapes. • Large tolerance for workpiece play because the actuator absorbs movement after activation. ★ • The steel wire enables easy workpiece length adjustment, and easy bending is possible. • Operation from any direction over 360° is possible, excluding the axial direction. • Lowest activation force of the limit switches. Effective for detection of non-uniform directions and shapes. • Large tolerance for workpiece play because the actuator absorbs movement after activation. Flexible rod Models Resin rod Steel wire Small Small ★ ★ Fork Lock Lever Models Fork Lock Lever Medium ★★ ★★★ • Self-rotates when operated to a position of 55°, holds state at the 90° position. • Reciprocating motion can be detected with a single dog. • To allow greater deviation in the roller position, two dogs can be used. *1. Indications for repeat accuracy and shock and vibration resistance are as follows: ★: OK, ★★: Good, ★★★: Excellent *2. The top line shows High-precision Switches. The bottom line shows Basic Switches. 4 WL-N/WL OMRON will combine the switch, Actuator, and wiring method required to build the ideal switch for your application. According to Operating Environment Environment Models Key specifications −10°C +80°C Ambient operating temperature Low-temperature To increase heat resistance, the rubber material have been changed. +40°C To increase resistance to cold, epichlorhydrin rubber and other measures are used. WL@-TH-N WLG@-TH Standard model *1 Environment-resistant, Low-temperature Switches High-sensitivity, High-precision model *1 WL@-TC-N WLG@-TC Environment-resistant, Heat-resistant Switches WLM@-N WLMG@ Outdoors A rubber material resistant to temperature changes is used. Stainless steel is used for the screws. The roller is made of stainless steel with superior corrosion resistance. Environment-resistant, Weather-proof Switches Standard model *1 High-sensitivity, High-precision model *1 WL@-P1-N WLG@-P1 Chemicals and oil Corrosion-proof specifications have been used for the housing, fluorine rubber has been used for rubber parts, and stainless steel has been used for screws and nuts (except for the actuator) to increase resistance to oils, chemicals, and weather. Environment-resistant, Standard model *1 Corrosion-proof Switches High-sensitivity, High-precision model *1 WL@-RP-N WLG@-RP Water drops and mist Uses an airtight built-in switch. Standard model *1 High-sensitivity, High-precision model *1 WL@-55-N WLG@-55 Cables are attached. Uses a general-purpose built-in switch. The cover screws, case cover, and conduit opening are molded from epoxy resin to increase the seal. (The cover cannot be removed.) Operating environment Standard model *1 High-sensitivity, High-precision model *1 +120°C +5°C −40°C WL@-N WLG@ Long-life Switches Water-resistant to IP67. High-temperature Standard model High-sensitivity, High-precision model Standard model High-sensitivity, High-precision model General-purpose Switches Normal Constant water drops and mist Environment-resistant, Airtight Switches Standard model *1*2 Environment-resistant, Molded-terminal Switches High-sensitivity, High-precision model *1*2 Cables are attached. Uses an airtight built-in switch. The case cover and conduit opening are molded from Standard model *1*2 epoxy resin to increase the seal. (The cover cannot be Environment-resistant, Molded-terminal Switches High-sensitivity, removed.) High-precision model *1*2 The SC connector can be removed, so it is possible to use flexible conduit for the cable. Cables are attached. Uses an airtight built-in switch. Environment-resistant, Standard model *1*2 The cover screws, case cover, and conduit opening are Molded-terminal Switches High-sensitivity, molded from epoxy resin to increase the seal. (The cover High-precision model *1*2 cannot be removed.) Constant water drops or splattering cutting powder Cables are attached. Uses an airtight built-in switch. The cover screws, case cover, and conduit opening are molded from epoxy resin to increase the seal. (The cover cannot be removed.) Two-layer seal on actuator rotation shaft. -141: The Head section is molded from epoxy resin; Head direction cannot be changed. -145: The Head section is molded from epoxy resin; Head can be in any of 4 directions. Coolant Cables are attached. Uses an airtight built-in switch. The cover screws, case cover, conduit opening, and head screws are molded from epoxy resin to increase the seal. (The cover and head cannot be removed.) Rubber parts are made from fluorine rubber to increase resistance to coolant. Spattering from welding To prevent spatter during welding, a heat-resistant resin is used for the indicator cover and screws and rollers are all made from stainless steel. Environment-resistant, Standard model *1*2 Molded-terminal Switches High-sensitivity, High-precision model *1*2 Environment-resistant, Standard model *1*2 Molded-terminal Switches High-sensitivity, High-precision model *1*2 WL@-139-N WLG@-139 WL@-RP40-N WLG@-RP40 WL@-140-N WLG@-140 WL@-141-N WLG@-141 WL@-145-N WLG@-145 Environment-resistant, Anti-coolant Switches Standard model *1*2 High-sensitivity, High-precision model *1*2 WL@-RP60-N WLG@-RP60 Spatter-prevention Switches Standard model High-sensitivity, High-precision model WL@-@S-N WLG2-@S WLGCA2-@S *1. Not all functions can be combined with environment-resistant models. *2. For details on the hermetic structure, see the hermetic mold specifications on pages 40 and 41. 5 WL-N/WL According to Application Conditions Conditions 10 A at 125,250, or 500 VAC 0.8 A at 125 VDC 0.4 A at 250 VDC Durability Load Switching standard loads Key specifications Switching microloads 0.1 A at 125 VAC, resistive load 0.1 A at 30 VDC, resistive load Normal durability Mechanical: 15 million operation min. (10 million operation min. for high-sensitivity models * or flexible rod models) Long-life Mechanical: 30 million operation min. Models General-purpose Switches Environment-resistant Switches Spatter-prevention Switches Long-life Switches Basic/Retention type Switches Basic Switches Basic Switches Basic Switches WL@-@-N General-purpose Switches Environment-resistant Switches Spatter-prevention Switches Long-life Switches High-sensitivity/High-precision Switches High-sensitivity/High-precision Switches High-sensitivity/High-precision Switches High-sensitivity/High-precision Switches WL WLG@ WLG@-S WLMG@ General-purpose Switches Basic/Retention type Switches WL@-@-N Applicable to either standard loads or microloads. Applicable to either standard loads or microloads. General-purpose Microload Switches High-sensitivity/High-precision Switches WL WL01G@ General-purpose Switches Spatter-prevention Switches Basic Switches Basic Switches WL@-N WL@-S-N General-purpose Switches Spatter-prevention Switches High-sensitivity/High-precision Switches High-sensitivity/High-precision Switches WL WLG@ WLG@-S Long-life Switches Basic Switches WLM@-N Long-life Switches High-sensitivity/ High-precision Switches WL WLMG@ According to Ease of Installation and Maintenance Operation indicator Conditions Daily inspections and maintenance checks Screw tightening and installation Key specifications Neon lamp 125 to 250 VAC Switching light-ON between operating/not operating. (Switching is not possible for Switches with Molded Terminals.) General-purpose, Indicator-equipped Switches Basic Switches High-sensitivity/High-precision Switches WL@-LE-N WLG@-LE Spatter-prevention Switches Basic Switches High-sensitivity/High-precision Switches WL@-LES-N WLG@-LES LED 10 to 115 VAC/DC Switching light-ON between operating/not operating. (Switching not possible for models with molded terminals.) General-purpose, Indicator-equipped Switches Basic Switches High-sensitivity/High-precision Switches WL@-LD-N WLG@-LD Spatter-prevention Switches Basic Switches High-sensitivity/High-precision Switches WL@-LDS-N WLG@-LDS General-purpose Switches Basic Switches High-sensitivity/High-precision Switches Basic Switches High-sensitivity/High-precision Switches WL@-N WLG@ WLM@-N WLMG@ General-purpose Switches Basic Switches High-sensitivity/High-precision Switches WL@-N WLG@ General-purpose Switches Basic Switches High-sensitivity/High-precision Switches Basic Switches High-sensitivity/High-precision Switches WL@-@LDK13@-N WLG@-@LDK13@ WLM@-LDK13@-N WLMG@-@LDK13@ General-purpose Switches Basic Switches High-sensitivity/High-precision Switches WL@-@LDK43@-N WLG@-@LDK43@ Long-life Switches Basic Switches High-sensitivity/High-precision Switches WLM@-LDK43@-N WLMG@-@LDK43@ General-purpose Switches Basic Switches High-sensitivity/High-precision Switches Basic Switches High-sensitivity/High-precision Switches Basic Switches High-sensitivity/High-precision Switches WL@-@LD-M1@J-N WLG@-@LD-M1@J WL@-@S-M1@J-1-N WLG@-@S-M1@J-1 WLM@-LD-M1@J-N WLMG@-LD-M1@J Basic Switches High-sensitivity/High-precision Switches Basic Switches High-sensitivity/High-precision Switches Basic Switches High-sensitivity/High-precision Switches WL@-@LD-@GJ-N WLG@-@LD-@GJ@ WL@-@S-@GJS-N WLG@-@S-@GJS@ WLM@-LD-@GJ-N WLMG@-LD-@GJ@ Screw terminals. No ground terminal. Conduit size: G1/2 Screw terminals. Ground terminal. Conduit size: 4 sizes Wiring specification Direct-wired connector, 2-conductor. Greatly reduces wiring work. One-touch connector attachment Connector attachment in control and relay boxes 6 Models Direct-wired connector, 4-conductor. Greatly reduces wiring work. Pre-wired connector, 2-conductor. Greatly reduces wiring work. Smartclick connectors for even easier maintenance. Long-life Switches Long-life Switches Spatter-prevention Switches Long-life Switches General-purpose Switches Pre-wired connector, 4-conductor. Greatly reduces wiring work. Smartclick connectors for even easier maintenance. Spatter-prevention Switches Long-life Switches WL-N/WL Application Examples Detection of Passing Pallets on Production Lines Detection of Work Table Origins (X, Y, and Z) on Machine Tools Detection of Forward and Reverse Movement of Hydraulic Cylinders on Molding Machines Detection of Arm Movement on Welding Robots Detection of Car Pallet Positions in Parking Towers Detection of Vertical Limits on Conveyor Systems 7 WL-N/WL Model Number Structure Model Number Legend (Not all combinations are possible. Ask your OMRON representative for details.) General-purpose Switches Standard Switches Operation indicator Switches Basic and Retention type Switches WL@ - @ @ @ @ -N (1) (2) (3) (4) (5) (1) Actuator and Property Specifications Code Code CA2 Roller lever: R38 mm Blank CA2-7 Roller lever: R50 mm 55 CA2-8 Roller lever: R63 mm CA12 Adjustable roller lever: R25 to 89 mm CL Adjustable rod lever: 25 to 140 mm CAL4 Adjustable rod lever: 350 to 380 mm CAL5 Rod spring lever CA2-2 Roller lever: R38 mm CA12-2 CL-2 CA2-2N CA12-2N CL-2N Adjustable roller lever: R25 to 89 mm Adjustable rod lever: 25 to 140 mm Roller lever: R38 mm Adjustable roller lever: R25 to 89 mm Adjustable rod lever: 25 to 140 mm CA32-41 Fork lock lever CA32-42 Fork lock lever CA32-43 8 Actuator (2) Built-in Switch Specifications Specifications Standard built-in switch Airtight built-in switch (3) Conduit Size, Ground Terminal Specifications Specifications Code Conduit Size Blank G1/2 G1 G1/2 G Pg13.5 Y TS None Provided * M20 1/2-14NPT * Models with ground terminals are certified for EN/IEC (CE Marking). (4) Indicator Specifications Fork lock lever Code D18 Sealed top plunger Blank D28 Sealed top-roller plunger LE Neon lamp: 125 to 250 VAC D38 Sealed top-ball plunger LD LED (10 to 115 VAC/DC) D2 Top-roller plunger SD Horizontal plunger SD2 Horizontal-roller plunger SD3 Horizontal-ball plunger Code NJ Flexible rod: Coil spring Blank NJ-30 Flexible rod: Coil spring, multi-wire NJ-2 Flexible rod: Resin rod NJ-S2 Flexible rod: Steel wire Ground terminal Specifications No indicator (5) Lever Specifications A Specifications Standard lever (Allen-head bolt) Double nut lever WL-N/WL Model Number Legend (Not all combinations are possible. Ask your OMRON representative for details.) General-purpose Switches Standard Switches Operation indicator Switches High-sensitivity and High-precision Switches WL@ @ - @ @ @ @ @ @ @ @ (1) (2) (3) (4) (5) (6) (7) (8) (9) (10) (1) Electrical Rating Code Blank 01 Specifications Standard load Microload (2) Actuator and Property Specifications Code Actuator G2 Roller lever: R38 mm High-sensitivity GCA2 Roller lever: R38 mm High-precision G12 Adjustable roller lever: R25 to 89 mm High-sensitivity GL Adjustable roller lever: 25 to 140 mm High-sensitivity (3) Built-in Switch Specifications Code Blank 55 Specifications Standard built-in switch Airtight built-in switch (4) Conduit Size, Ground Terminal Specifications Specifications Code Conduit Size Blank G1/2 G1 G1/2 G Pg13.5 Y M20 TS Ground terminal None Provided * 1/2-14NPT * Models with ground terminals are certified for EN/IEC (CE Marking). (5) Indicator Type Code Blank Specifications No indicator LE Neon lamp: 125 to 250 VAC LD LED (10 to 115 VAC/DC) (6) Lever Type Code Blank A Specifications Standard lever (Allen-head bolt) Double nut lever 9 WL-N/WL Model Number Legend (Not all combinations are possible. Ask your OMRON representative for details.) General-purpose Switches Sensor I/O Connector Switches Basic and Retention type Switches WL@ - @ L D @ -N (1) (2) (3) (4) (1) Actuator and Property Specifications Code Actuator CA2 Roller lever: R38 mm D28 Sealed top-roller plunger D2 Top-roller plunger (2) Built-in Switch Specifications Code Blank 55 Specifications Standard built-in switch Airtight built-in switch (3) Indicator Specifications Code LD Specifications LED (10 to 115 VAC/DC) (4) Connector Type Wiring Specifications Specifications Code Shape Voltage *1 Wiring locations AC NO only NO: 3 4 DC NO only NO: 3 4 AC NC+NO NC: 1 2 , NO: 3 4 K43 DC NC+NO NC: 1 2 , NO: 3 4 -M1J DC NO only NO: 3 4 -M1GJ DC NO only NO: 1 4 -M1JB DC NC only NC: 3 2 AC NC+NO NC: 1 2 , NO: 3 4 DC NC+NO NC: 1 2 , NO: 3 4 DC NO only NC: 2 , NO: 3 4 -M1TJ DC NO only NO: 3 4 -M1TGJ DC NO only NO: 1 4 DC NC only NC: 3 2 -DTGJ DC NC+NO NC: 1 2 , NO: 3 4 -DTK1EJ DC NO only NC: 2 , NO: 3 4 K13A K13 K43A Direct-wire Connector type Threaded (M12) Threaded (M12) -AGJ -DGJ -DK1EJ -M1TJB Pre-wired Connector type *3 Smartclick Connector pin No. *2 *1. DC models are certified for EN/IEC (CE Marking). *2. Refer to Contact Forms on page 21 for details on connector pin numbers. *3. The standard cable length is 0.3 m. Contact your OMRON representative for information on other cable lengths. 10 WL-N/WL Model Number Legend (Not all combinations are possible. Ask your OMRON representative for details.) General-purpose Switches Sensor I/O Connector Switches High-sensitivity and High-precision Switches WL@ @ - @ L D @ -N (1) (2) (3) (4) (5) (1) Electrical Rating Code Blank 01 Specifications Standard load Microload (2) Actuator and Property Specifications Code Actuator G2 Roller lever: R38 mm High-sensitivity GCA2 Roller lever: R38 mm High-precision (3) Built-in Switch Specifications Code Blank 55 Specifications Standard built-in switch Airtight built-in switch (4) Indicator Specifications Code LD Specifications LED (10 to 115 VAC/DC) (5) Connector Type Wiring Specifications Specifications Code Shape K13A K13 K43A Direct-wire Connector type Voltage *1 Wiring locations AC NO only Connector pin No. *2 DC NO only NO: 3 4 AC NC+NO NC: 1 2 , NO: 3 4 NO: 3 4 K43 DC NC+NO NC: 1 2 , NO: 3 4 -M1J *1 DC NO only NO: 3 4 DC NO only NO: 1 4 DC NC only NC: 3 2 NC: 1 2 , NO: 3 4 Threaded (M12) -M1GJ *1 -M1JB -AGJ03 Pre-wired Connector type *3 AC NC+NO -DGJ03 *1 DC NC+NO NC: 1 2 , NO: 3 4 -DK1EJ03 *1 DC NO only NC: 2 , NO: 3 4 *1. DC models are certified for EN/IEC (CE Marking). *2. Refer to Contact Forms on page 21 for details on connector pin numbers. *3. The standard cable length is 0.3 m. Contact your OMRON representative for information on other cable lengths. 11 WL-N/WL Model Number Legend (Not all combinations are possible. Ask your OMRON representative for details.) Environment-resistant Switches Basic Switches WL@ - @ @ @ @ @ @ @ @ -N (1) (2) (3) (4) (5) (6) (7) (8) (9) (1) Actuator and Property Specifications Code Actuator CA2 Roller lever: R38 mm CA2-7 Roller lever: R50 mm CA2-8 Roller lever: R63 mm CA12 Adjustable roller lever: R25 to 89 mm CL Adjustable rod lever: 25 to 140 mm Adjustable rod lever: 350 to 380 mm CAL5 Rod spring lever CA2-2 Roller lever: R38 mm CA12-2 Adjustable roller lever: R25 to 89 mm CL-2 CA12-2N CL-2N 140 Airtight built-in switch. Cable is attached. Molded conduit opening, cover, and cover screws. (The cover cannot be removed.) 141 Conduit opening, cover, head, cover attachment screw part, airtight built-in switch. Cable is attached. Molded head screws. (The cover cannot be removed and the head direction cannot be changed.) Two-layer seal on actuator rotation shaft. 145 Airtight built-in switch. Cable is attached. Molded conduit opening, cover, and cover screws. (The cover cannot be removed. The head can be mounted in any of 4 directions.) Two-layer seal on actuator rotation shaft. RP40 Airtight built-in switch. Cable is attached. Molded conduit opening and cover. (The cover cannot be removed.) SC Connector can be removed, so it is possible to use flexible conduits for the cable. RP60 Airtight built-in switch. Cable is attached. Molded conduit opening, cover, cover screws, and head screws. (The cover cannot be removed and the head direction cannot be changed.) Fluorine rubber is used for all rubber parts. Adjustable rod lever: 25 to 140 mm Fork lock lever CA32-42 Fork lock lever Fork lock lever D18 Sealed top plunger D28 Sealed top-roller plunger D38 Sealed top-ball plunger D2 Top-roller plunger SD Horizontal plunger SD2 Horizontal-roller plunger SD3 Horizontal-ball plunger NJ Standard built-in switch. Cable is attached. Molded conduit opening and cover. (The cover cannot be removed.) Roller lever: R38 mm Adjustable roller lever: R25 to 89 mm Flexible rod: Coil spring Specifications No cable molding. 139 Adjustable rod lever: 25 to 140 mm CA32-41 CA32-43 Code Blank CAL4 CA2-2N (5) Hermetic Specifications (6) Conduit Size, Ground Terminal Specifications Specifications Code Conduit Size NJ-30 Flexible rod: Coil spring, multi-wire NJ-2 Flexible rod: Resin rod Blank G1/2 NJ-S2 Flexible rod: Steel wire G1 G1/2 G Pg13.5 Y M20 (2) Environment-resistant Model Specifications Code Blank Specifications Corrosion-proof P1 Weather-resistant Code 55 Specifications TC Code Blank Specifications No indicator LE Neon lamp: 125 to 250 VAC *3 Airtight built-in switch LD LED (10 to 115 VAC/DC) *3 Code TH 1/2-14NPT Standard built-in switch (4) Temperature Specifications Blank Provided *2 (7) Indicator Specifications (3) Built-in Switch Specifications Blank None *2. Models with ground terminals are certified for EN/IEC (CE Marking). Standard RP TS Ground terminal Specifications *3. Cannot be combined with Corrosion-proof (RP), Weather-proof (P1), Heat-resistant (TC), or Low-temperature (TC) Switches. (8) Indicator Wiring Specifications Standard: -10 to +80°C Heat-resistant: -5 to +120°C *1 Low-temperature: -40 to +40°C *1 *1. Cannot be combined with Corrosion-proof (RP) or Weather-proof (P1) Switches. Code Specifications 2 NC connection: Light-ON when operating *4 3 NO connection: Light-ON when not operating *4 *4. Always include the indicator wiring specification if you specify a (5) hermetic structure and an (7) indicator. (9) Lever Type Code Blank A 12 Specifications Standard lever (Allen-head bolt) Double nut lever WL-N/WL Model Number Legend (Not all combinations are possible. Ask your OMRON representative for details.) Environment-resistant Switches High-sensitivity and High-precision Switches WL@ @ - @ @ @ @ @ @ @ @ (1) (2) (3) (4) (5) (6) (7) (8) (9) (10) (1) Electrical Rating Code Blank 01 (6) Hermetic Specification Specifications Standard load Microload (2) Actuator and Property Specifications Code Roller lever: R38 mm High sensitivity GCA2 Roller lever: R38 mm High-precision G12 Adjustable roller lever: R25 to 89 mm High sensitivity GL Adjustable rod lever: 25 to 140 mm High sensitivity (3) Environment-resistant Model Specifications Code P1 Weather-proof (4) Built-in Switch Specifications Code 55 140 Airtight built-in switch. Cable is attached. Molded conduit opening, cover, and cover screws. (The cover cannot be removed.) 141 Conduit opening, cover, head, cover attachment screw part, airtight built-in switch. Cable is attached. Molded head screws. (The cover cannot be removed and the head direction cannot be changed.) Two-layer seal on actuator rotation shaft. 145 Airtight built-in switch. Cable is attached. Molded conduit opening, cover, and cover screws. (The cover cannot be removed. The head can be mounted in any of 4 directions.) Two-layer seal on actuator rotation shaft. RP40 Airtight built-in switch. Cable is attached. Molded conduit opening and cover. (The cover cannot be removed.) SC Connector can be removed, so it is possible to use flexible conduits for the cable. RP60 Airtight built-in switch. Cable is attached. Molded conduit opening, cover, cover screws, and head screws. (The cover cannot be removed and the head direction cannot be changed.) Fluorine rubber is used for all rubber parts. Specifications Corrosion-proof Blank Standard built-in switch. Cable is attached. Molded conduit opening and cover. (The cover cannot be removed.) Standard RP Specifications No cable molding. 139 Actuator G2 Blank Code Blank Specifications Standard built-in switch Airtight built-in switch (7) Conduit Size, Ground Terminal Specifications (5) Temperature Specifications Code Specifications Specifications Code Conduit Size Blank G1/2 Standard: -10 to +80°C G1 G1/2 TH Heat-resistant: -5 to +120°C *1 G Pg13.5 TC Low-temperature: -40 to +40°C *1 Y M20 Blank *1. Cannot be combined with Corrosion-proof (RP) or Weather-proof (P1) Switches. TS Ground terminal None Provided *2 1/2-14NPT *2. Models with ground terminals are certified for EN/IEC (CE Marking). (8) Indicator Type Code Blank Specifications No indicator LE Neon lamp: 125 to 250 VAC *3 LD LED (10 to 115 VAC/DC) *3 *3. Cannot be combined with Corrosion-proof (RP), Weather-proof (P1), Heat-resistant (TC), or Low-temperature (TC) Switches. (9) Indicator Wiring Specification Code Specifications 2 NC connection: Light-ON when operating *4 3 NO connection: Light-ON when not operating *4 *4. Always include the indicator wiring specification if you specify a (6) hermetic structure and an (8) indicator. (10) Lever Type Code Blank A Specifications Standard lever (Allen-head bolt) Double nut lever 13 WL-N/WL Model Number Legend (Not all combinations are possible. Ask your OMRON representative for details.) Spatter-prevention Switches Basic Switches WL@ - @ @ S@ -N (1) (2) (3) (4) (1) Actuator and Property Specifications Code (3) Indicator Specifications Actuator Code Specifications CA2 Roller lever: R38 mm LE Neon lamp: 125 to 250 VAC *1 D28 Sealed top-roller plunger LD LED (10 to 115 VAC/DC) *1. Cannot be combined with a (4) Connector Type Wiring Specifications. (2) Built-in Switch Specifications Code Blank 55 Specifications Standard built-in switch Airtight built-in switch (4) Connector Type Wiring Specifications Specifications Code Blank Shape Screw terminal type -M1J-1 -M1GJ-1 -DGJS Pre-wired Connector type *4 -DTGJS Threaded (M12) Smartclick Voltage *2 Wiring locations --- --- Connector pin No. *3 DC NO only NO: 3 4 NO: 1 4 --- DC NO only DC NC+NO NC: 1 2 , NO: 3 4 DC NC+NO NC: 1 2 , NO: 3 4 *2. DC models are certified for EN/IEC (CE Marking). *3. Refer to Contact Forms on page 21 for details on connector pin numbers. *4. The standard cable length is 0.3 m. Contact your OMRON representative for information on other cable lengths. Spatter-prevention Switches High-sensitivity and High-precision Switches WL@ @ - @ @ S@ (1) (2) (3) (4) (5) (1) Electrical Rating Code Blank 01 (3) Built-in Switch Specifications Specifications Code Standard load Blank Microload 55 (2) Actuator and Property Specifications Code Specifications Standard built-in switch Airtight built-in switch (4) Indicator Specifications Actuator Code Specifications Blank Roller lever: R38 High-sensitivity LE Neon lamp: 125 to 250 VAC *1 GCA2 Roller lever: R38 High-precision LD LED (10 to 115 VAC/DC) *1. Cannot be combined with a (5) Connector Type Wiring Specifications. (5) Connector Type Wiring Specifications Specifications Code Blank Shape Screw terminal type -M1J -1 -M1GJ -1 -DGJS03 Pre-wired Connector type *4 Threaded (M12) Voltage *2 Wiring locations --- --- Connector pin No. *3 DC NO only NO: 3 4 DC NO only NO: 1 4 DC NC+NO NC: 1 2 , NO: 3 4 --- *2. DC models are certified for EN/IEC (CE Marking). *3. Refer to Contact Forms on page 21 for details on connector pin numbers. *4. The standard cable length is 0.3 m. Contact your OMRON representative for information on other cable lengths. 14 WL-N/WL Model Number Legend (Not all combinations are possible. Ask your OMRON representative for details.) Basic Switches Long-life Switches WLM@ - LD@ -N (1) (2) (3) (1) Actuator and Property Specifications Code Actuator CA2 Roller lever: R38 mm (2) Indicator Type Code Specifications LD LED (10 to 115 VAC/DC) (3) Connector Type Wiring Specifications Specifications Code Shape Blank Screw terminal type K13A K13 Direct-wire Connector type K43A Threaded (M12) Voltage Wiring locations --- --- Connector pin No. *1 AC NO only DC NO only NO: 3 4 AC NC+NO NC: 1 2 , NO: 3 4 --NO: 3 4 K43 DC NC+NO NC: 1 2 , NO: 3 4 -M1J DC NO only NO: 3 4 NC: 1 2 , NO: 3 4 -AGJ Threaded (M12) -DGJ Pre-wired Connector type *2 -M1TJ Smartclick -DTGJ AC NC+NO DC NC+NO NC: 1 2 , NO: 3 4 DC NO only NO: 3 4 DC NC+NO NC: 1 2 , NO: 3 4 *1. Refer to Contact Forms on page 21 for details on connector pin numbers. *2. The standard cable length is 0.3 m. Contact your OMRON representative for information on other cable lengths. High-sensitivity and High-precision Switches Long-life Switches WLM@ - LD@ (1) (2) (3) (1) Actuator and Property Specifications Code Actuator G2 Roller lever: R38 mm High-sensitivity GCA2 Roller lever: R38 mm High-precision (2) Indicator Type Code LD Specifications LED (10 to 115 VAC/DC) (3) Connector Type Wiring Specifications Specifications Code Blank Shape Voltage Screw terminal type K13A K13 K43A Direct-wire Connector type K43 Threaded (M12) -M1J -AGJ03 -DGJ03 Pre-wired Connector type *2 Wiring locations Connector pin No. *1 --- --- AC NO only --- DC NO only NO: 3 4 AC NC+NO NC: 1 2 , NO: 3 4 NC: 1 2 , NO: 3 4 NO: 3 4 DC NC+NO DC NO only NO: 3 4 AC NC+NO NC: 1 2 , NO: 3 4 DC NC+NO NC: 1 2 , NO: 3 4 *1. Refer to Contact Forms on page 21 for details on connector pin numbers. *2. The standard cable length is 0.3 m. Contact your OMRON representative for information on other cable lengths. 15 WL-N/WL Ordering Information General-purpose Switches Standard Switches Switches with Roller Lever Actuators Basic Switches Actuator Roller lever: R38 Pretravel (PT) Roller lever: R50 Model Roller lever: R63 Model WLCA2-N 25±5° WLCA2-2-N --- --- 20° max. WLCA2-2N-N --- --- Actuator WLCA2-7-N Model 15±5° Adjustable rod lever: 25 to 140 mm Adjustable roller lever Pretravel (PT) Model WLCA2-8-N Adjustable rod lever: 350 to 380 mm Model Rod spring lever Model WLCAL4-N Model 15±5° WLCA12-N WLCL-N WLCAL5-N 25±5° WLCA12-2-N WLCL-2-N --- --- 20° max. WLCA12-2N-N WLCL-2N-N --- --- High-sensitivity Switches Actuator Roller lever: R38 Load Adjustable roller lever Model Adjustable rod lever: 25 to 140 mm Model Model Standard load WLG2 WLG12 WLGL Microload WL01G2 WL01G12 WL01GL High-precision Switches Actuator Roller lever: R38 Load Model Standard load WLGCA2 Microload WL01GCA2 Switches with Plunger Actuators Basic Switches Actuator Pretravel (PT) 1.7 mm max. Sealed Top-roller plunger Sealed Top Plunger Model Model WLD18-N Actuator Horizontal plunger Pretravel (PT) 2.8 mm max. WLD28-N Horizontal-roller plunger Model Model WLSD-N WLSD2-N Sealed Top-ball plunger Top-roller plunger Model WLD38-N Model WLD2-N Horizontal-ball plunger Model WLSD3-N Switches with Flexible Rod Actuators Basic Switches Actuator Coil spring (spring diameter: 6.5) Pretravel (PT) 20±10 mm Coil spring (spring diameter: 4.8) Model Model WLNJ-N Actuator WLNJ-30-N Resin rod (rod diameter: 8) Pretravel (PT) 40±20 mm Steel wire (wire diameter: 1) Model WLNJ-2-N WLNJ-S2-N Switches with Fork Lock Lever Actuator Retention type Switches Actuator Pretravel (PT) 55° max. 16 Fork lock lever Model WLCA32-41-N Fork lock lever Model WLCA32-42-N Fork lock lever Model WLCA32-43-N Fork lock lever Model WLCA32-44-N WL-N/WL General-purpose Switches Operation indicator Switches Switches with Roller Lever Actuators Basic Switches Actuator Roller lever: R38 Indicator * Neon lamp LED Pretravel (PT) Model WLCA2-LE-N 25±5° WLCA2-2LE-N --- 20° max. WLCA2-2NLE-N --- 15±5° WLCA2-LD-N WLCA2-7LD-N Model WLCA2-8LE-N ----WLCA2-8LD-N WLCA2-2LD-N --- --- 20° max. WLCA2-2NLD-N --- --- Pretravel (PT) 15±5° LED WLCA2-7LE-N Roller lever: R63 25±5° Adjustable roller lever Neon lamp Model 15±5° Actuator Indicator * Roller lever: R50 Adjustable rod lever: 25 to 140 mm Model Model Adjustable rod lever: 350 to 380 mm Rod Spring Lever Model Model WLCAL4-LE-N WLCAL5-LE-N WLCA12-LE-N WLCL-LE-N 25±5° WLCA12-2LE-N WLCL-2LE-N --- 20° max. WLCA12-2NLE-N WLCL-2NLE-N --- 15±5° WLCA12-LD-N WLCL-LD-N 25±5° WLCA12-2LD-N WLCL-2LD-N --- --- 20° max. WLCA12-2NLD-N WLCL-2NLD-N --- --- WLCAL4-LD-N ----WLCAL5-LD-N High-sensitivity Switches Actuator Roller lever R38 Indicator * Neon lamp LED Pretravel (PT) 10° +2° -1° Model WLG2-LE WLG2-LD Actuator Adjustable roller lever Indicator * Neon lamp LED Pretravel (PT) 10° +2° -1° Adjustable rod lever: 25 to 140 mm Model Model WLG12-LE WLGL-LE WLG12-LD WLGL-LD High-precision Switches Actuator Roller lever R38 Indicator * Neon lamp LED Pretravel (PT) 5° +2° 0° Model WLGCA2-LE WLGCA2-LD Switches with Fork Lock Lever Actuator Retention type Switches Actuator Fork lock lever Indicator * Neon lamp LED Pretravel (PT) 55° max. Model WLCA32-41LE-N WLCA32-41LD-N Fork lock lever Model WLCA32-42LE-N --- Fork lock lever Model WLCA32-43LE-N WLCA32-43LD-N * The default setting is light-ON when not operating (NO wiring). Turn the lamp holder by 180° to change the setting to light-ON when operating (NC wiring). 17 WL-N/WL Switches with Plunger Actuators Basic Switches Actuator Indicator * Neon lamp LED Pretravel (PT) 1.7 mm max. Actuator Indicator * Neon lamp LED Pretravel (PT) 2.8 mm max. Sealed Top plunger Sealed Top-roller plunger Model Model Sealed Top-ball plunger Model Top-roller plunger Model WLD18-LE-N WLD28-LE-N WLD38-LE-N WLD2-LE-N WLD18-LD-N WLD28-LD-N WLD38-LD-N WLD2-LD-N Horizontal plunger Horizontal-roller plunger Model Model Horizontal-ball plunger Model WLSD-LE-N WLSD2-LE-N WLSD3-LE-N WLSD-LD-N WLSD2-LD-N WLSD3-LD-N Switches with Flexible Rod Actuators Basic Switches Actuator Indicator * Neon lamp LED Pretravel (PT) 20±10 mm Actuator Indicator * Neon lamp LED Pretravel (PT) 40±20 mm Coil spring (spring diameter: 6.5) Model Coil spring (spring diameter: 8) Model WLNJ-LE-N WLNJ-30LE-N WLNJ-LD-N WLNJ-30LD-N Resin rod (rod diameter: 8) Model Steel wire (wire diameter: 1) Model WLNJ-2LE-N WLNJ-S2LE-N WLNJ-2LD-N WLNJ-S2LD-N * The default setting is light-ON when not operating (NO wiring). Turn the lamp holder by 180° to change the setting to light-ON when operating (NC wiring). 18 WL-N/WL General-purpose Switches Sensor I/O Connector Switches Switches with Direct-wired Connectors Basic Switches Actuator Sealed Top-roller plunger Roller lever: R38 Connector shape Built-in switch specification Voltage Wiring Specifications Generalpurpose Threaded DC Airtight DC Pretravel (PT) Model Model 2 core NO 3 4 WLCA2-LDK13A-N --- NC + NO 4 core NC 1 2 NO 3 4 WLCA2-LDK43A-N --- NO only 2 core NO 3 4 NC + NO 4 core NC 1 2 NO 3 4 NO only 2 core NC + NO 4 core NO only AC Connector pin No. WLCA2-LDK13-N WLD28-LDK13-N WLCA2-LDK43-N WLD28-LDK43-N NO 3 4 WLCA2-55LDK13-N WLD28-55LDK13-N NC 1 2 NO 3 4 WLCA2-55LDK43-N WLD28-55LDK43-N 15±5° High-sensitivity Switches Actuator Roller lever: R38 Connector shape Built-in switch specification Voltage DC Airtight Connector pin No. 2 core NO 3 4 NC + NO 4 core NC 1 2 NO 3 4 NO only 2 core NO 3 4 NC + NO 4 core NC 1 2 NO 3 4 NO only Generalpurpose Threaded Wiring Specifications Pretravel (PT) Model WLG2-LDK13 WLG2-LDK43 10° +2° -1° WLG2-55LDK13 WLG2-55LDK43 High-precision Switches Actuator Roller lever: R38 Connector shape Built-in switch specification Voltage DC Airtight Connector pin No. 2 core NO 3 4 NC + NO 4 core NC 1 2 NO 3 4 NO only 2 core NO 3 4 NC + NO 4 core NC 1 2 NO 3 4 NO only Generalpurpose Threaded Wiring Specifications Pretravel (PT) Model WLGCA2-LDK13 WLGCA2-LDK43 5° +2°0° WLGCA2-55LDK13 WLGCA2-55LDK43 Note: The default setting is light-ON when not operating (NO wiring). Turn the lamp holder by 180° to change the setting to light-ON when operating (NC wiring). (However, Four-core Switches cannot be switched to light-ON when operating (NC wiring).) 19 WL-N/WL Switches with Pre-wired Connectors Basic Switches Actuator Sealed Top-roller Plunger Roller lever: R38 Connector shape Built-in switch specification Voltage Generalpurpose Threaded * Wiring Specifications Connector pin No. Pretravel (PT) Model Model NO 3 4 WLCA2-LD-M1J-N WLD28-LD-M1J-N NO 1 4 WLCA2-LD-M1GJ-N WLD28-LD-M1GJ-N --- NO only 2 core NC only 2 core NC 3 2 WLCA2-LD-M1JB-N NC + NO 4 core NC 1 2 NO 3 4 WLCA2-LD-DGJ-N WLD28-LD-DGJ-N NO only NO 3 4 NC 2 WLCA2-LD-DK1EJ-N WLD28-LD-DK1EJ-N WLCA2-55LD-M1J-N WLD28-55LD-M1J-N 3 core DC NO only 2 core NC only NO 3 4 15±5° NO 1 4 WLCA2-55LD-M1GJ-N WLD28-55LD-M1GJ-N 2 core NC 3 2 WLCA2-55LD-M1JB-N WLD28-55LD-M1JB-N NC + NO 4 core NC 1 2 NO 3 4 WLCA2-55LD-DGJ-N NO only NO 3 4 NC 2 WLCA2-55LD-DK1EJ-N Airtight 3 core --WLD28-55LD-DK1EJ-N High-sensitivity Switches Actuator Roller lever: R38 Connector shape Built-in switch specification Voltage DC Airtight Connector pin No. 2 core NO 3 4 NC + NO 4 core NC 1 2 NO 3 4 NO only 2 core NO 3 4 NC + NO 4 core NC 1 2 NO 3 4 NO only Generalpurpose Threaded * Wiring Specifications Pretravel (PT) Model WLG2-LDK13 WLG2-LDK43 10° +2° -1° WLG2-55LDK13 WLG2-55LDK43 High-precision Switches Actuator Roller lever: R38 Connector shape Built-in switch specification Voltage DC Airtight Connector pin No. Pretravel (PT) Model 2 core NO 3 4 WLG2-LDK13 NC + NO 4 core NC 1 2 NO 3 4 WLG2-LDK43 NO only 2 core NO 3 4 NC + NO 4 core NC 1 2 NO 3 4 NO only Generalpurpose Threaded * Wiring Specifications 5° +2°0° WLG2-55LDK13 WLG2-55LDK43 * The standard cable length for a pre-wired connector is 0.3 m. Contact your OMRON representative for information on other cable lengths. Note: The default setting is light-ON when not operating (NO wiring). Turn the lamp holder by 180° to change the setting to light-ON when operating (NC wiring). (However, Three-core and Four-core Switches cannot be switched to light-ON when operating (NC wiring).) 20 WL-N/WL Contact Forms Wiring specification Screw terminal types No indicator Basic Switches High-sensitivity/ High-precision Switches Za 14 (NO) 13 (NO) (NO) 4 12 (NC) (NC) 1 Za Operation indicator (Light-ON when Not Operating) Switches High-sensitivity/ Basic Switches High-precision Switches Za 14 (NO) 11 (NC) Internal circuits Internal circuits 3 (NO) 13 (NO) (NO) 4 12 (NC) (NC) 1 Za 3 (NO) 2 (NC) 11 (NC) 2 (NC) Direct-wire Connector and Pre-wired Connector types No indicator Basic High-sensitivity/High-precision Switches AC AC DC Za NO NC 2 core 4 --4 core 4 DC Za Za --- 3 4 --- --- 3 NO NC 2 core 4 --- 2 3 2 core 4 --- --- 1 4 core 4 --- 3 2 --- 1 2 3 4 indicate the connector 4 core 4 1 2 3 NC NO 1 Za NO NC 1 2 3 4 indicate the connector pin number. NC NO NC NO 1 NO NC NC NO --- 3 4 --- --- 2 3 2 core 4 --- --- 1 --- 3 2 --- 3 core 4 --- 2 3 4 core 4 1 2 3 pin number. 1 2 3 4 indicate the connector pin number. 3 1 2 3 4 indicate the connector pin number. Operation indicator (Light-ON when Not Operating) Switches Basic High-sensitivity/High-precision Switches Internal circuits AC Internal circuits DC Za NO NC 2 core 4 --4 core 4 Za NC NO --- 3 1 Internal circuits AC 2 3 2 core 1 2 3 4 indicate the connector pin number. 4 core Internal circuits DC Za Za NO NC NC NO 4 --- --- 3 2 core 4 --- --- 3 4 --- --- 4 --- --- 1 4 core 4 1 2 3 2 core 4 --- --- 1 --- 3 2 --- 1 2 3 4 indicate the connector --- 3 2 --- 4 1 2 3 3 core 4 --- 2 3 4 core 4 1 2 3 NO NC pin number. 1 2 3 4 indicate the connector pin number. NC NO NO NC NC NO 3 1 2 3 4 indicate the connector pin number. Connector Pin Layout Diagram Basic/High-sensitivity/High-precision Switches AC Positioning piece *2 DC Positioning piece *2 2 2 3 1 4 3 1 4 Note: Leakage current from indicator circuit may cause load malfunction (i.e., the load may remain ON). Make sure that the load operating current is higher than the leakage current. For countermeasures, refer to technical support on your OMRON website. *1. Light-ON when not operating means the operation indicator is lit when the actuator is free and is not light when the Switch contacts (NO) close when the actuator rotates or is pushed down. *2. The position of the positioning piece is not always the same. If using an L-shaped connector causes problems in application, use a straight connector. 21 WL-N/WL Connecting Sensor I/O connector cable (Socket) Type Number of cable cores AC/DC Type Cable length L (m) 2 AC 4 M12 Screw (Straight) 2 DC 4 M12 Smart click type (Straight) DC Applicable limit switch models Model 2m XS2F-A421-DB0-F 5m XS2F-A421-GB0-F 2m XS2F-A421-D90-F 5m XS2F-A421-G90-F 2m XS2F-D421-DD0 5m XS2F-D421-GD0 2m XS2F-D421-DA0-F 5m XS2F-D421-GA0-F 2m XS2F-D421-D80-F 5m XS2F-D421-G80-F 2m XS5F-D421-D80-F WL@-@K13A-N WL@-@K43A-N WL@-@-AGJ-N WL@-@K13-N WL@-@-M1J-N WL@-@-M1GJ@-N WL@-@K43-N WL@-@-M1JB-N WL@-@-DGJ-N WL@-@-M1TJ-N WL@-@-M1TJB-N 4 5m XS5F-D421-G80-F Dimensions (Unit: mm) XS2F-@421-@@0-@ XS2F-D421-@D0 L (Cable length) 40.7 6 dia. 14.9 dia. DC AC 30 5 50 Wiring Diagram Two-core model AC/DC Type Model Terminal No. AC Four-core model Wiring Diagram XS2F-A421-DB0-F XS2F-A421-GB0-F Model Cable color of core sheath 1 2 3 4 XS2F-A421-D90-F XS2F-A421-G90-F Brown Blue Terminal No. XS2F-D421-DD0 XS2F-D421-GD0 Cable color of core sheath 1 2 3 4 1 2 3 4 Blue Brown Terminal No. XS2F-D421-D80-F XS2F-D421-G80-F Cable color of core sheath 1 2 3 4 Cable color of core sheath Brown White Blue Black Terminal No. DC XS2F-D421-DA0-F XS2F-D421-GA0-F Wiring Diagram Brown Blue XS5F-D421-@80-F Wiring Diagram L (Cable length) 40.7 AC/DC Type Model Wiring Diagram Terminal No. 5 30 50 DC 22 Four-core model 6 dia. 14.9 dia. XS5F-D421-D80-F XS5F-D421-G80-F 1 2 3 4 Cable color of core sheath Brown White Blue Black WL-N/WL Environment-resistant Switches Switches with Roller Lever Actuators Basic Switches Actuator Roller lever: R38 Built-in switch specification Adjustable roller lever Model WLCA2-55-N Airtight seal Molded terminals, -139 models Model WLCA12-55-N WLCA2-255-N --- WLCA2-2N55-N --- WLCA2-139-N WLCA12-139-N WLCA2-2139-N --- WLCA2-2N139-N --- WLCA2-140-N Molded terminals, -140 models WLCA12-140-N --WLCA2-2N140-N Hermetic seal * WLCA2-141-N Molded terminals, -141 models ----WLCL-139-N ----WLCL-140-N --- --- --- ----- --- --- --Anti-coolant Model WLCL-55-N WLCA12-141-N --WLCA2-RP60-N Adjustable rod lever: 25 to 140 mm --WLCA12-RP60-N WLCA2-2RP60-N --- --WLCL-RP60-N --- --- --- --- WLCA2-TH-N WLCA12-TH-N WLCL-TH-N WLCA2-2TH-N WLCA12-2TH-N WLCL-2TH-N WLCA2-2NTH-N WLCA12-2NTH-N WLCL-2NTH-N WLCA2-TC-N WLCA12-TC-N WLCL-TC-N WLCA2-2TC-N WLCA12-2TC-N WLCL-2TC-N WLCA2-2NTC-N WLCA12-2NTC-N WLCL-2NTC-N Corrosion-proof WLCA2-RP-N WLCA12-RP-N WLCL-RP-N Weather-proof WLCA2-P1-N WLCA12-P1-N WLCL-P1-N Adjustable roller lever Adjustable rod lever: 25 to 140 mm Heat-resistant Low-temperature * The maximum cable length for a Hermetic Switch is 5 m. High-sensitivity Switches Actuator Roller lever: R38 Built-in switch specification Model Model WLG2-55 Model --- --- Molded terminals, -139 models WLG2-139 --- --- Molded terminals, -140 models WLG2-140 --- --- Molded terminals, -141 models WLG2-141 --- --- Anti-coolant WLG2-RP60 --- --- Airtight seal Hermetic seal * Heat-resistant WLG2-TH WLG12-TH WLGL-TH Low-temperature WLG2-TC WLG12-TC WLGL-TC Corrosion-proof WLG2-RP WLG12-RP WLGL-RP Weather-proof WLG2-P1 WLG12-P1 WLGL-P1 * The maximum cable length for a Hermetic Switch is 5 m. High-precision Switches Actuator Built-in switch specification Airtight seal Hermetic seal * Roller lever: R38 Model WLGCA2-55 Molded terminals, -139 models WLGCA2-139 Molded terminals, -140 models WLGCA2-140 Molded terminals, -141 models WLGCA2-141 Anti-coolant WLGCA2-RP60 Heat-resistant WLGCA2-TH Low-temperature WLGCA2-TC Corrosion-proof WLGCA2-RP Weather-proof --- * The maximum cable length for a Hermetic Switch is 5 m. 23 WL-N/WL Switches with Plunger Actuators Basic Switches Actuator Sealed Top-roller plunger Built-in switch specification Model Airtight seal Hermetic seal * Top-roller plunger Model WLD28-55-N WLD2-55-N Molded terminals, -139 models WLD28-139-N WLD2-139-N Molded terminals, -140 models WLD28-140-N Anti-coolant WLD28-RP60-N WLD2-RP60-N WLD28-TH-N WLD2-TH-N Heat-resistant --WLSD-RP60-N Built-in switch specification Hermetic seal * WLSD2-140-N WLSD2-RP60-N WLSD-TH-N WLSD2-TH-N WLSD-TC-N WLSD2-TC-N WLD28-RP-N --- WLSD-RP-N WLSD2-RP-N Coil spring (spring diameter: 6.5) Model Resin rod (rod diameter: 8) Model WLNJ-55-N WLNJ-255-N Molded terminals, -139 models WLNJ-139-N WLNJ-2139-N Molded terminals, -140 models WLNJ-140-N WLNJ-2140-N Anti-coolant WLNJ-RP60-N WLNJ-2RP60-N Heat-resistant WLNJ-TH-N --- Low-temperature WLNJ-TC-N --- Corrosion-proof WLNJ-RP-N * The maximum cable length for a Hermetic Switch is 5 m. 24 WLSD2-139-N --- Switches with Flexible Rod Actuators Basic Switches Airtight seal Model WLSD2-55-N WLSD-139-N --- * The maximum cable length for a Hermetic Switch is 5 m. Actuator Model WLSD-55-N Horizontal-roller plunger --- Low-temperature Corrosion-proof Horizontal plunger WLNJ-2RP-N WL-N/WL Environment-resistant Switches Operation indicator Switches Switches with Roller Lever Actuators Basic Switches Actuator Built-in switch specification Indicator * Neon lamp Airtight seal LED Molded terminals, -139 models Hermetic seal Molded terminals, -140 models LED Anti-coolant Wiring Specifications Roller lever: R38 Adjustable roller lever Model NO wiring WLCA2-55LE-N NO wiring WLCA2-255LE-N NO wiring WLCA2-2N55LE-N NO wiring WLCA2-55LD-N Model WLCA12-55LE-N ----WLCA12-55LD-N Adjustable rod lever: 25 to 140 mm Model ------WLCL-55LD-N NO wiring WLCA2-255LD-N --- NO wiring WLCA2-2N55LD-N --- ----- NC wiring WLCA2-139LD2-N --- --- NO wiring WLCA2-139LD3-N --- --- NC wiring WLCA2-2139LD2-N --- --- NO wiring WLCA2-2139LD3-N --- --- NC wiring WLCA2-141LD2-N --- --- NO wiring WLCA2-141LD3-N --- --- NC wiring WLCA2-RP60LD2-N --- --- NO wiring WLCA2-RP60LD3-N --- --- NC wiring WLCA2-2RP60LD2-N --- --- NO wiring WLCA2-2RP60LD3-N --- --- High-sensitivity Switches Actuator Built-in switch specification Airtight seal Hermetic seal Roller lever: R38 Indicator * Wiring Specifications Neon lamp NO wiring WLG2-55LE LED NO wiring WLG2-55LD Model Molded terminals, -139 models NC wiring --- NO wiring WLG2-139LD3 Molded terminals, -140 models NC wiring WLG2-140LD2 NO wiring WLG2-140LD3 LED Molded terminals, -141 models Anti-coolant NC wiring WLG2-141LD2 NO wiring WLG2-141LD3 NC wiring WLG2-RP60LD2 NO wiring WLG2-RP60LD3 High-precision Switches Actuator Built-in switch specification Airtight seal Hermetic seal Roller lever: R38 Indicator * Wiring Specifications Neon lamp NO wiring WLGCA2-55LE LED NO wiring WLGCA2-55LD Model Molded terminals, -139 models NC wiring WLGCA2-139LD2 NO wiring WLGCA2-139LD3 Molded terminals, -140 models NC wiring WLGCA2-140LD2 NO wiring WLGCA2-140LD3 LED Molded terminals, -141 models Anti-coolant NC wiring NO wiring --WLGCA2-141LD3 NC wiring WLGCA2-RP60LD2 NO wiring WLGCA2-RP60LD3 * The default setting is light-ON when not operating (NO wiring). Turn the lamp holder by 180° to change the setting to light-ON when operating (NC wiring). (Note that the lamp holder cannot be replaced on hermetic models.) 25 WL-N/WL Switches with Plunger Actuators Basic Switches Actuator Internal switch Specifications Airtight seal Sealed top-roller plunger Top-roller plunger Indicator * Wiring Specifications Neon lamp NO wiring WLD28-55LE-N WLD2-55LE-N LED NO wiring WLD28-55LD-N WLD2-55LD-N Model Model * The default setting is light-ON when not operating (NO wiring). Turn the lamp holder by 180° to change the setting to light-ON when operating (NC wiring). Switches with Flexible Rod Actuators Basic Switches Actuator Internal switch Specifications Airtight seal Coil spring (spring diameter: 6.5) Resin rod (rod diameter: 8) Indicator * Wiring Specifications Neon lamp NO wiring --- --- LED NO wiring WLNJ-55LD-N WLNJ-255LD-N Model Model * The default setting is light-ON when not operating (NO wiring). Turn the lamp holder by 180° to change the setting to light-ON when operating (NC wiring). 26 Horizontal plunger Model --WLSD-55LD-N Horizontal-roller plunger Model --WLSD2-55LD-N WL-N/WL Spatter-prevention Switches Basic Switches Actuator Roller lever: R38 Sealed Top-roller plunger Double nut lever Indicator * Allen-head lever Model Model Model Neon lamp WLCA2-LEAS-N WLCA2-LES-N WLD28-LES-N LED WLCA2-LDAS-N WLCA2-LDS-N WLD28-LDS-N High-sensitivity Switches Actuator Roller lever: R38 Double nut lever Indicator * Allen-head lever Model Model Neon lamp WLG2-LEAS WLG2-LES LED WLG2-LDAS WLG2-LDS High-precision Switches Actuator Roller lever: R38 Double nut lever Indicator * Model Allen-head lever Model Neon lamp --- WLGCA2-LES LED --- WLGCA2-LDS * The default setting is light-ON when not operating (NO wiring). Turn the lamp holder by 180° to change the setting to light-ON when operating (NC wiring). 27 WL-N/WL Long-life Switches Basic Switches Actuator Indicator *1 Roller lever Screw terminal type AC/DC Type Wiring Specifications Connectors pin No. AC/DC --- --- AC Roller lever Direct-wire Connector type LED Roller lever Pre-wired Connector type *2 DC Model WLMCA2-LD-N 2-conductor NO 3 4 WLMCA2-LDK13A-N 4-conductor NC 1 2 NO 3 4 WLMCA2-LDK43A-N 2-conductor NO 3 4 WLMCA2-LDK13-N 4-conductor NC 1 2 NO 3 4 WLMCA2-LDK43-N 2-conductor NO 3 4 WLMCA2-LD-M1J-N 4-conductor NC 1 2 NO 3 4 WLMCA2-LD-DGJ-N DC *1. The default setting is light-ON when not operating (NO wiring). Turn the lamp holder by 180° to change the setting to light-ON when operating (NC wiring). (However, Four-core Switches cannot be switched to light-ON when operating (NC wiring).) *2. With 0.3-m cable. High-sensitivity/High-precision Switches Actuator Indicator *1 Roller lever Screw terminal type AC/DC Type Wiring Specifications Connectors pin No. AC/DC --- --- AC Roller lever Direct-wire Connector type Roller lever Pre-wired Connector type *2 LED DC High-precision Models Model Model WLMG2-LD WLMGCA2-LD 2-conductor NO 3 4 WLMG2-LDK13A WLMGCA2-LDK13A 4-conductor NC 1 2 NO 3 4 WLMG2-LDK43A WLMGCA2-LDK43A 2-conductor NO 3 4 WLMG2-LDK13 WLMGCA2-LDK13 4-conductor NC 1 2 NO 3 4 WLMG2-LDK43 WLMGCA2-LDK43 2-conductor NO 3 4 WLMG2-LD-M1J WLMGCA2-LD-M1J 4-conductor NC 1 2 NO 3 4 WLMG2-LD-DGJ03 DC *1. The default setting is light-ON when not operating (NO wiring). Turn the lamp holder by 180° to change the setting to light-ON when operating (NC wiring). (However, Four-core Switches cannot be switched to light-ON when operating (NC wiring).) *2. With 0.3-m cable. 28 High-sensitivity --- WL-N/WL Individual Parts Switches without Levers, Heads, and Actuators General-purpose Parts Operating characteristics Actuator Roller lever Basic High-sensitivity Adjustable roller lever Basic High-sensitivity Variable rod lever Basic High-sensitivity Fork lock lever Top plunger Horizontal plunger Flexible rod Basic Set Model Model Model WL-1H1100-N WLCA2-2-N WLRCA2-2-N WL-3H1100-N WLCA2-2N-N WLRCA2-2N-N WL-1H1100-N WLG2 WLRG2 WL-2H1100 WLCA12-N WLRCA2-N WL-1H2100-N WLCA12-2-N WLRCA2-2-N WL-3H2100-N WLCA12-2N-N WLRCA2-2N-N WL-1H2100-N WLG12 WLRG2 WL-2H2100 WLCL-N WLRCL-N WL-4H4100-N WLCL-2-N WLRCA2-2-N WL-3H4100-N WLCL-2N-N WLRCA2-2N-N WL-1H4100-N WLGL WLRG2 WL-1A100 WL-2A100 WL-4A100 WL-2H4100 WLCA32-41-N WL-5H5100-N WL-5A100 WLCA32-42-N WL-5H5102-N WL-5A102 WL-5H5104-N WL-5A104 WLCA32-44-N WL-5H5104-N WL-5A104 WLD18-N WL-7H100-N --- WL-7H400-N --- WLD38-N WL-7H300-N --- WLSD-N WL-8H100-N --- WL-8H200-N --- WLSD2-N WLRCA32-N --- --- WLSD3-N WL-8H300-N --- WLNJ-N WL-9H100-N --- WLNJ-30-N Basic Actuator only * WLRCA2-N WLD28-N Basic Heads (with Actuators) WLCA2-N WLCA32-43-N Basic Switches without levers WLNJ-2-N --- WLNJ-S2-N WL-9H200-N --- WL-9H300-N --- WL-9H400-N --- * The same Actuators can be used for both WL and WL-N Switches. Spatter-prevention Parts Actuator Lever Specifications Allen-head bolt lever Item Basic High-sensitivity Roller lever Double nut lever Basic High-sensitivity Set Model Numbers Switches without levers Heads (with Actuators) Actuator only * Model Model Model WLCA2-LES-N WLRCA2-LES-N WLCA2-LDS-N WLRCA2-LDS-N WLG2-LDS WLRG2-LDS WLCA2-LEAS-N WLRCA2-LES-N WLCA2-LDAS-N WLRCA2-LDS-N WLG2-LDAS WLRG2-LDS --- WL-1A103S --- WL-1A105S * The same Actuators can be used for both WL and WL-N Switches. 29 WL-N/WL Covers with Indicators (See Note.) General-purpose/Long-life Parts Basic Parts Cover Indicator *2 Neon lamp LED Cover only *1 Color Model Orange WL-LE-N *3 Red WL-LD-N Yellow WL-LW-N *3 High-sensitivity/High-precision Parts Cover Indicator *2 Cover only *1 Color Model Neon lamp Orange WL-LE LED Red WL-LD *1. The Covers are not compatible with Basic Switches (WL-N), or High-sensitivity/High-precision Switches (WL). *2. The default setting is light-ON when not operating (NO wiring). Turn the lamp holder by 180° to change the setting to light-ON when operating (NC wiring). *3. The Color Universal Design structure is certified by an NPO. Color Universal Design was developed in consideration of people with various types of color vision to allow information to Certification conditions: Ambient illumination of 500 lx max. (JIS be accurately conveyed to as many individuals as possible. Z 9110) Spatter-prevention Parts Basic Parts Cover Indicator * Cover only Color Model Neon lamp Orange WL-LES-N LED Red WL-LDS-N * The default setting is light-ON when not operating (NO wiring). Turn the lamp holder by 180° to change the setting to light-ON when operating (NC wiring). 30 WL-N/WL Specifications General-purpose/Environment-resistant Switches Ratings Wiring Specifications Screw terminal types Standard-load Switches (excluding micro-load Switches) Item Resistive load NC NO Lamp load NC NO Inductive load (A) Inductive load NC NO NC NO 5 3 1.5 2.5 1.5 0.8 AC 125 250 500 10 10 10 3 2 1.5 1.5 1 0.8 10 10 3 Basic DC 10 10 6 0.8 0.4 6 6 4 0.2 0.1 3 3 3 0.2 0.1 10 10 6 0.8 0.4 Highsensitivity Highprecision *1 AC 125 250 5 5 ---- ---- ---- DC 125 250 0.4 0.2 ---- ---- ---- 8 14 30 125 250 Rated voltage (V) Motor load 6 6 4 0.2 0.1 NC Note: The load is a resistive load. Operation in the following ranges will produce optimum performance. 5 to 30 VDC 0.16 to 100 mA Recommended load range 30 10 5 0.8 W 5 mW 1 0.1 0.16 1 5 10 100 Operating characteristics 30 A max. (15 A max. *1) NO 0.1 DC 30 Note: 1. The above figures are for steady-state currents. 2. Inductive loads have a power factor of 0.4 min. (AC) and a time constant of 7 ms max. (DC). 3. A lamp load has an inrush current of 10 times the steadystate current. 4. A motor load has an inrush current of 6 times the steadystate current. Inrush current Rated current (A) - Resistive load AC125 Voltage (VDC) Non-inductive load (A) Rated voltage (V) Micro-load Switches (Refer to these ratings before using the product.) High-sensitivity, High-precision 20 A max. (10 A max. *1) Current (mA) Minimum applicable load 5 VDC 1 mA N level reference value *1. For High-sensitivity and High-precision Switches. Operating characteristics Minimum applicable load Basic 5 VDC 1 mA, resistive load, P level High-sensitivity, High-precision 5 VDC 160 mA, resistive load, N level reference value Operation indicator Switches Operation Indicator Model Direct-wired connector and Pre-wired Connector type Non-inductive load (A) Rated voltage (V) Item Resistive load NC NO Lamp load NC NO 3 1.5 Inductive load (A) Inductive load NC NO NC 3 Basic DC 3 3 0.8 Highsensitivity Highprecision *1 AC 115 3 ---- ---- ---- DC 115 0.4 ---- ---- ---- 3 3 0.2 3 3 0.8 Neon lamp WL-LD-N WL-LW-N WL-LD LED Leakage current (mA) 125 VAC Approx. 0.6 250 AC Approx. 1.9 10 to 24 VAC/DC Approx. 0.4 115 VAC/DC Approx. 0.5 NO AC 115 12 24 115 3 Motor load Max. rated voltage (V) WL-LE-N WL-LE 3 2.5 3 3 0.2 Note: 1. The above figures are for steady-state currents. 2. Inductive loads have a power factor of 0.4 min. (AC) and a time constant of 7 ms max. (DC). 3. A lamp load has an inrush current of 10 times the steadystate current. 4. A motor load has an inrush current of 6 times the steadystate current. Inrush current NC 3 A max. NO 3 A max. Operating characteristics Minimum applicable load Basic 5 VDC 1 mA, resistive load, P level High-sensitivity, High-precision 5 VDC 160 mA, RESISTIVE Load, N level reference value 31 WL-N/WL Characteristics Degree of protection Durability *1 15,000,000 operations min. *2 Electrical 750,000 operations min. (3 A at 250 VAC, resistive load) *3 Mechanical 120 operations/minute min. Electrical 30 operations/minute min. Operating speed Operating frequency IP67 Mechanical 1 mm to 1 m/s (for WLCA2-N) Rated frequency 50/60 Hz Insulation resistance 100 MΩ min. (at 500 VDC) Contact resistance 25 mΩ max. (initial value for the built-in switch when tested alone) Between terminals of the same polarity Dielectric strength 1,000 VAC (600 VAC) 50/60 Hz 1 min Between currentcar2,200 VAC (1,500 VAC) 50/60 Hz rying metal part and 1 min *5 ground Between each termi2,200 VAC (1,500 VAC) 50/60 Hz nal and non-current1 min *5 carrying metal part Vibration resistance Shock resistance Malfunction 10 to 55 hz, 1.5-mm double amplitude *6 Destruction 1,000 m/s2 max. Malfunction 300 m/s2 *6 Ambient operating temperature -10 to +80°C (with no icing) *7 Ambient operating humidity 35% to 95% RH Weight Approx. 255 g (for WLCA2-N) Note: 1. The above figures are initial values. 2. The figures in parentheses for dielectric strength are those for the high-sensitivity and high-precision switches models. *1. The values are calculated at an operating temperature of +5°C to +35°C, and an operating humidity of 40% to 70% RH. Contact your OMRON sales representative for more detailed information on other operating environments. *2. High-sensitivity models and Flexible Rod models: 10 million operations min. 500,000 operations min. for Weather-resistant models. *3. High-sensitivity models, High-precision models, and Weatherproof models are 500,000 operations min. Micro-load models are 1 million operations min. Contact your OMRON representative for information on Airtight models and Hermetic models. *4. Micro-load models and Weather-proof models are 50 mΩ or less (default value, built-in switch only). *5. Sensor I/O connector type is 1,500 V. *6. Except Flexible Rod models. Micro-load models are 200 m/s2 max. *7. For low-temperature models this is –40°C to +40°C (with no icing). For heat-resistant models the range is +5°C to +120°C. 32 WL-N/WL Spatter-prevention Switches Ratings Wiring Specifications Characteristics Degree of protection Screw terminal types Durability *1 Non-inductive load (A) Item Rated voltage (V) WL@-LES-N AC 125 250 Resistive load NC WL@-LDS-N NO 10 (5) 10 (5) Lamp load NC NO 3 2 1.5 1 Inductive load (A) Inductive load NC NO 10 10 AC 115 10 (5) 3 1.5 10 DC 10 6 0.8 (0.4) 6 4 0.2 3 3 0.2 10 6 0.8 12 24 115 Motor load NC NO 5 3 2.5 1.5 5 2.5 6 4 0.2 Note: 1. The above figures are for steady-state currents. 2. Inductive loads have a power factor of 0.4 min. (AC) and a time constant of 7 ms max. (DC). 3. A lamp load has an inrush current of 10 times the steadystate current. 4. A motor load has an inrush current of 6 times the steadystate current. 5. The figures in parentheses for resistive load are those for the high-sensitivity and high-precision switches models. Inrush current NC 30 A max. (15 A max. *) NO 20 A max. (10 A max. *) Operating characteristics Minimum applicable load Basic 5 VDC 1 mA, resistive load, P level High-sensitivity, High-precision 5 VDC 160 mA, Resistive load, N level reference value Direct-wired connector and Pre-wired Connector type Non-inductive load (A) Rated voltage (V) Item Resistive load NC NO Lamp load NC NO 3 1.5 Inductive load (A) Inductive load NC NO NC NO AC 115 3 Basic DC 3 3 0.8 Highsensitivity Highprecision *1 AC 115 3 ---- ---- ---- DC 115 0.4 ---- ---- ---- 12 24 115 3 3 0.2 3 Motor load 3 3 3 0.8 2.5 3 3 0.2 Electrical 750,000 operations min. (3 A at 250 VAC, resistive load) *3 1 mm to 1 m/s (in case of WLCA2LDS-N) Mechanical 120 operations/minute min. Electrical 30 operations/minute min. Rated frequency 50/60Hz Insulation resistance 100 MΩ min. (at 500 VDC) Contact resistance 25 mΩ max. (initial value for the built-in switch) Between terminals of the same polarity Dielectric strength 1,000 VAC (600 VAC) 50/60 Hz 1 min Between currentcar2,200 VAC (1,500 VAC) 50/60 Hz rying metal part and 1 min *4 ground Between each termi2,200 VAC (1,500 VAC) 50/60 Hz nal and non-current1 min *4 carrying metal part Vibration resistance Shock resistance * For High-sensitivity and High-precision Switches. 15,000,000 operations min. *2 Operating speed Operating frequency IP67 Mechanical Malfunction 10 to 55 hz, 1.5-mm double amplitude Destruction 1,000 m/s2 max. Malfunction 300 m/s2 max. Ambient operating temperature -10 to +80°C (with no icing) Ambient operating humidity 35% to 95% RH Weight Approx. 255 g (in case of WLCA2LDS-N) Note: 1. The above figures are initial values. 2. The figures in parentheses for dielectric strength are those for the high-sensitivity and high-precision switches models. *1. The values are calculated at an operating temperature of +5°C to +35°C, and an operating humidity of 40% to 70%RH. Contact your OMRON sales representative for more detailed information on other operating environments. *2. High-sensitivity models are 10 million operations min. *3. High-sensitivity models and High-precision models are 500,000 operations min. Micro-load models are 10 million operations min. Contact your OMRON representative for information on Airtight switches. *4. Sensor I/O connector type is 1,500 V. Note: 1. The above figures are for steady-state currents. 2. Inductive loads have a power factor of 0.4 min. (AC) and a time constant of 7 ms max. (DC). 3. A lamp load has an inrush current of 10 times the steadystate current. 4. A motor load has an inrush current of 6 times the steadystate current. Inrush current NC 3 A max. NO 3 A max. Operating characteristics Minimum applicable load Basic 5 VDC 1 mA, resistive load, P level High-sensitivity, High-precision 5 VDC 160 mA, Resistive load, N level reference value Operation indicator Switches Operation Indicator Model WL-LES-N WL-LE WL-LDS-N WL-LD Neon lamp LED Max. rated voltage (V) Leakage current (mA) 125 VAC Approx. 0.6 250 VAC Approx. 1.9 10 to 24 VAC/DC Approx. 0.4 115 VAC/DC Approx. 0.5 33 WL-N/WL Long-life Switches Ratings Wiring Specifications Characteristics Degree of protection Screw terminal type Rated voltage (V) Item Non-inductive load (A) Resistive load NC Basic Highsensitivity Highprecision * Inductive load NC NO 10 3 1.5 10 DC 10 6 0.8 6 4 0.2 3 3 0.2 10 6 0.8 AC 115 5 DC 115 NC ---- 0.4 NO Motor load NC ---- ---- ---- NC 30 A max. (15 A max. *) NO 20 A max. (10 A max. *) * For High-sensitivity and High-precision Switches. Minimum applicable load 1 mm to 1 m/s (in case of WLMCA2-LD-N) Operating speed Operating frequency Mechanical 120 operations/min. Electrical 30 operations/min. Rated frequency 50/60 Hz Insulation resistance 100 MΩ min. (at 500 VDC) Contact resistance 25 mΩ max. (initial value for the built-in switch when tested alone) *2 Between terminals of the same polarity Dielectric strength (50/60 Hz 1 min.) Vibration resistance 1,000 VAC (600 VAC), 50/60 Hz 1 min Between currentcar2,200 VAC (1,500 VAC) 50/60 Hz rying metal part and 1 min *3 ground Between each termi2,200 VAC (1,500 VAC) 50/60 Hz nal and non-current1 min *3 carrying metal part Malfunction 10 to 55 Hz, 1.5-mm double amplitude Destruction 1,000 m/s2 max. Malfunction 300 m/s2 max. *4 Basic 5 VDC 1 mA, resistive load, P level Shock resistance High-sensitivity, High-precision 5 VDC 160 mA, Resistive load, N level reference value Ambient operating temperature -10 to +80°C (with no icing) Ambient operating humidity 35% to 95% RH Weight Approx. 255 g (in case of WLMCA2-LD-N) Direct-wired connector and Pre-wired Connector type Rated voltage (V) Item Non-inductive load (A) Resistive load NC NO Lamp load NC NO 3 1.5 Inductive load (A) Inductive load NC NO NC NO AC 115 3 Basic DC 3 3 0.8 Highsensitivity Highprecision *1 AC 115 3 ---- ---- ---- DC 115 0.4 ---- ---- ---- 12 24 115 3 3 0.2 3 Motor load 3 3 3 0.8 2.5 3 3 0.2 Note: 1. The above figures are for steady-state currents. 2. Inductive loads have a power factor of 0.4 min. (AC) and a time constant of 7 ms max. (DC). 3. A lamp load has an inrush current of 10 times the steadystate current. 4. A motor load has an inrush current of 6 times the steadystate current. Inrush current NC 3 A max. NO 3 A max. Operating characteristics Minimum applicable load Basic 5 VDC 1 mA, resistive load, P level High-sensitivity, High-precision 5 VDC 160 mA, Resistive load, N level reference value Operation indicator Switches Operation Indicator Model WL-LD-N WL-LW-N WL-LD 34 Durability *1 2.5 6 4 0.2 ---- ---- Operating characteristics Electrical 30,000,000 operations min. (10 mA at 24 VDC, resistive load) 750,000 operations min. (3 A at 115 VAC, resistive load), but for high-precision models: High-sensitivity and High-precision Switches: 500,000 operations min. NO 5 Note: 1. The above figures are for steady-state currents. 2. Inductive loads have a power factor of 0.4 min. (AC) and a time constant of 7 ms max. (DC). 3. A lamp load has an inrush current of 10 times the steadystate current. A motor load has an inrush current of 6 times the steadystate current. Inrush current 30,000,000 operations min. Inductive load (A) AC 115 12 24 115 NO Lamp load IP67 Mechanical LED Max. rated voltage (V) Leakage current (mA) 10 to 24 VAC/DC Approx. 0.4 115 VAC/DC Approx. 0.5 Note: 1. The above figures are initial values. 2. The figures in parentheses for dielectric strength are those for the high-sensitivity and high-precision switches models. *1. The values are calculated at an operating temperature of +5°C to +35°C, and an operating humidity of 40% to 70%RH. Contact your OMRON sales representative for more detailed information on other operating environments. *2. For microload models, the contact resistance is 50 mΩ max. (initial value for built-in switch). *3. Sensor I/O connector models are 1,500 V. *4. Micro-load models are 200 m/s2 max. WL-N/WL General-purpose/Environment-resistant/Spatter-prevention/Long-life Switches Approved Standards Agency Standard UL UL508 File No. CSA cUL CSA C22.2 No.14 TÜV Rheinland EN60947-5-1 CCC (CQC) GB14048.5 Approved models Contact your OMRON representative for information Contact your OMRON representative for information Approved Standard Ratings UL/cUL, CSA (UL508, CSA C22.2 No.14) Specifications Indicator No indicator Approved Standards Rated voltage Basic Switches A600 1 A, 125 VDC High-sensitivity or high-precision A600 120 VAC 240 VAC 480 VAC 600 VAC Basic, high-sensitivity or high-precision C300 3 A, 250 VAC Sensor I/O connectors No Connector Pre-wired Connector (AC) Item Basic Switches Pre-wired Connector (DC) Direct-wired Connector (DC) High-sensitivity or high-precision Basic Switches Neon lamp No Connector High-sensitivity or high-precision Pre-wired Connector (AC) Basic, high-sensitivity or high-precision Rated voltage 0.8 A, 125 VDC 120 VAC 240 VAC A300 10 A, 250 VAC C300 3 A, 250 VAC A150 10 A, 115 VAC 1 A, 115 VDC High-sensitivity or high-precision A150 10 A, 115 VAC 0.8 A, 115 VDC LED Basic, high-sensitivity or high-precision Basic Switches Pre-wired Connector (DC) Direct-wired Connector (DC) High-sensitivity or high-precision C150 3 A, 115 VAC 1 A, 115 VDC 0.8 A, 115 VDC TÜV (EN 60947-5-1) With ground terminals Neon lamp With DC Connector LED Working load category AC-15 DC-12 AC-15 AC-15 DC-12 DC-12 Rated working voltage (Ue) 250 V 48 V 250 V 115 V 48 V 48 V Rated working current (Ie) 2A Conditional short-circuit current Short-circuit protective device (SCPD) 100 A 10 A, fuse type gG Rated insulation voltage (Ui) 250 V 48 V Rated impulse dielectric strength (Uimp) 4 kV 800 V Pollution degree Electric shock protection class Volt-ampere (VA) Break Make Break 60 30 15 12 6 3 1.5 1.2 7,200 720 Energizing current 2.5 A Current (A) Volt-ampere (VA) Make Break Make Break 15 7.5 1.5 0.75 1,800 180 A300 Authentication conditions Rated voltage 120 VAC 240 VAC Energizing current 10 A Current (A) Volt-ampere (VA) Make Break Make Break 60 30 6 3 7,200 720 A150 Authentication conditions Current (A) Volt-ampere (VA) Rated voltage Energizing current Make Break Make Break 120 VAC 10 A 60 6 7,200 720 C150 Authentication conditions Current (A) Rated voltage Energizing current Make 120 VAC 2.5 A 15 Authentication conditions Specification No indicator 10 A Current (A) Make Volt-ampere (VA) Break 1.5 Make Break 1,800 180 CCC (GB14048.5) (Certification Only for Switches with Ground Terminals and DC Switches with Connectors) Authentication conditions Energizing current C300 Authentication conditions 1 A, 125 VDC Basic Switches No Connector Pre-wired Connector (AC) A600 Authentication conditions Specification No indicator Neon lamp LED Working load category AC-15 DC-13 AC-15 AC-15 DC-13 Rated working voltage (Ue) 250 V Rated working current (Ie) Conditional short-circuit current 48 V 250 V 250 V With DC Connector With AC Connector DC-13 AC-15 48 V 250 V 48 V 2A 1000 A Short-circuit protective device (SCPD) 10 A, fuse type gG Rated insulation voltage (Ui) 250 V 3 Class I Class III 35 WL-N/WL Structure and Nomenclature General-purpose Switches: WLCA2-N Actuator Standard Switches Basic Switches Head-mounting Screws Roller The roller is made of self-lubricating sintered stainless steel and boasts high resistance to wear. Head Lever The lever is forged from corrosion-resistant aluminum alloy. It provides superior corrosion resistance and outstanding strength. With roller lever, adjustable rod and flexible rod models, the actuator position can be set anywhere within 360°. (The lever cannot be mounted in the opposite direction.) You can remove the two screws to mount the switch in any of the four possible orientations. Shaft Section Seal An oil seal is fitted on the inlet of the shaft section to maintain a tight seal. Roller Lever Bolt Operational Plunger Set Position Marker Plate Set the indicator needle so that it is between protrusions on the bearing section on the marker plate after operation. Head Set position marker plate You can change the direction of the operational plunger to electrically switch the direction of operation between both sides, left only, or right only. Built-in Switch Built-in switch with SPST-NO+NC contact form. Requires maintenance (excessive overtravel) Proper range Requires maintenance (insufficient overtravel) Proper range Terminal Screws Four, M3.5 screws Requires maintenance (excessive overtravel) Cover Setscrew A combination Philips-slotted screw is used. A retainer prevents the screw from falling from the cover even when the screw is loose. Cover Cover Seal High sealing performance is achieved. The seal also serves as a spacer. There is no troublesome insulating paper, making it easy to work with the Switch. 36 Conduit Opening The conduit screw is a parallel screw for G1/2 piping, and is used together with an SC connector to maintain a tight seal. WL-N/WL General-purpose Switches: WLG2 Standard Switches Head-mounting Screws Head By removing the four corner screws, the head can be mounted in any of four orientations. High-sensitivity and High-precision Switches Actuator Roller The roller is made of self-lubricating sintered stainless steel and boasts high resistance to wear. Lever Shaft Section Seal By fitting an O-ring to the rotary shaft and with an appropriate interference of the screws, high-sealing properties are maintained. The lever forged of anti-corrosive aluminium alloy features high corrosion resistances and outstanding ruggedness. With roller lever, adjustable rod and flexible rod models, the actuator position can be set anywhere within 360°. (The lever cannot be mounted in the opposite direction.) Roller Lever Setscrew Operational Plunger Bearing The bearing smooths the plunger movement. Set Position Marker Plate After operation, set the indicator needle on the marker plate so that is in the convex section of the bearing. Built-in Switch Built-in switch with SPST-NO+NC contact form. Requires maintenance (excessive overtravel) Proper range Requires maintenance (insufficient overtravel) Proper range Requires maintenance (excessive overtravel) Terminal Screws Four, M4 screws Separator The separator has outstanding insulation properties and prevents the generation of any gases which may corrode the internal parts. Conduit Opening The conduit screw is a parallel screw for G1/2 piping, and is used together with an SC connector to maintain a tight seal. Cover Seal By using a packing seal as the cover seal, an optimum squeeze can be obtained and high sealing properties are assured as well. Cover Cover Setscrew A combination Philips-slotted screw is used. A retainer prevents the screw from falling from the cover even when the screw is loose. 37 WL-N/WL Basic Switches Operation indicator Switches Indicator Covers Indicator The indicator covered if outsert molded from diecast aluminum and has outstanding sealing properties. The indicator is either a neon lamp or an LED. Switches with LED indicators have a built-in rectifier stack, so there is no connection polarity. Indicator Windows Operating status (i.e., light-ON when operating or light-ON when not operating) depends on whether a neon lamp or an LED is used. Contact Spring Light-ON when Operating/Not Operating Lamp Holder Indicators can be switched from light-ON when operating and light-ON when not operating, by simply rotating the indicator holder by 180°. (However, Direct-wired Connector, Pre-wired Connector, Three-core, and Four-core Switches cannot be switched to light-ON when operating (NC wiring).) Light-ON when Operating The built-in switch's terminal screws are used to connect the indicator terminal. Since the connection spring (coil spring) is used for this connection, it will not be necessary to connect the indicator terminal. When a ground terminal is provided however, a lead wire must be used. Light-ON when Not Operating LED at top LED at bottom Operation Light-ON when Not Operating Internal Circuits Power Neon lamp Built-in switch Light-ON when operating *1 14 Za WL@-LE-N 13 Contact spring Resistor 11 12 Load Internal circuits WL@-LE-N WL@-LD-N WL@-LW-N Internal circuits Light-ON when not operating *2 Rectifier stack Contact spring Power Resistor Za 14 13 11 12 Load WL@-LD-N WL@-LW-N Zener diode Rated current diode Resistor LED Built-in switch Note: Leakage current from indicator circuit may cause load malfunction (i.e., the load may remain ON). Make sure that the load operating current is higher than the leakage current. For countermeasures, refer to technical support on your OMRON website. *1. Light-ON when operating means that the lamp lights when the Limit Switch contacts (NC) release, or when the actuator rotates or is pushed down. *2. Light-ON when not operating means the lamp remains lit when the actuator is free, or when the Limit Switch contacts (NO) close when the actuator rotates or is pushed down. 38 WL-N/WL High-sensitivity and High-precision Switches Operation indicator Switches Indicator Covers Indicator The indicator covered if outsert molded from diecast aluminum and has outstanding sealing properties. The indicator is either a neon lamp or an LED. Switches with LED indicators have a built-in rectifier stack, so there is no connection polarity. Indicator Windows Operation (i.e., light-ON when operating or light-ON when not operating) depends on whether a neon lamp or LED is used. Contact Spring The built-in switch's terminal screws are used to connect the indicator terminal. Since the connection spring (coil spring) is used for this connection, it will not be necessary to connect the indicator terminal. When a ground terminal is provided however, a lead wire must be used. Light-ON when Operating/Not Operating Indicators can be switched from light-ON when operating and light-ON when not operating, by simply rotating the indicator holder by 180°. (However, Direct-wired Connector, Pre-wired Connector, Three-core, and Four-core Switches cannot be switched to light-ON when operating (NC wiring).) Light-ON when Operating Light-ON when Not Operating LED at top LED at bottom Operation Internal Circuits Power Light-ON when Not Operating Neon lamp Built-in switch Light-ON when operating *1 4 Za WLG@-LE 3 Contact spring Resistor 1 2 Load Internal circuits WLG@-LE WLG@-LD Rectifier stack Contact spring Power Resistor Internal circuits Light-ON when not operating *2 WLG@-LD Za 4 3 1 2 Load Zener diode Rated current diode Resistor LED Built-in switch Note: Leakage current from indicator circuit may cause load malfunction (i.e., the load may remain ON). Make sure that the load operating current is higher than the leakage current. For countermeasures, refer to technical support on your OMRON website. *1. Light-ON when operating means that the lamp lights when the Limit Switch contacts (NC) release, or when the actuator rotates or is pushed down. *2. Light-ON when not operating means the lamp remains lit when the actuator is free, or when the Limit Switch contacts (NO) close when the actuator rotates or is pushed down. 39 WL-N/WL Basic Switches Environment-resistant Switches Molding Specifications for Hermetic Switches WL@-139-N : Molded parts WL@-140-N WL@-141-N Head cap Airtight built-in switch Standard built-in switch WL@-145-N Head cap Oil seal Airtight built-in switch WL@-RP40-N WL@-RP60-N *1 Oil seal Airtight built-in switch Airtight built-in switch Airtight built-in switch *1. Fluorine rubber is used for all rubber parts. Model WL@-139-N WL@-140-N WL@-141-N WL@-145-N WL@-RP40-N WL@-RP60-N Cable specifications Standard 5-m VCT cable. Finished outer diameter: 11.5 mm, 4 conductors. Standard 5-m VCT cable, with high flexibility and good anti-oil properties attached. Finished outer diameter: 11.5 mm, 4 conductors. Connector specifications Resin cap Metal connector Resin connector *2 Resin cap *2. The connector can be removed, so it is possible to use flexible conduit for the cable. 40 WL-N/WL High-sensitivity and High-precision Switches Environment-resistant Switches Mold Specifications for Hermetic Seal Switches : Molded parts WLG@-139 WLG@-140 WLG@-141 Oil seal for protection against cutting powder X-ring Standard built-in switch Airtight built-in switch WLG@-145 Airtight built-in switch WLG@-RP40 Oil seal for protection against cutting powder X-ring WLG@-RP60 *1 O-ring Airtight built-in switch Airtight built-in switch Airtight built-in switch *1. Fluorine rubber is used for all rubber parts. Model WLG@-139 WLG@-140 WLG@-141 WLG@-145 WLG@-RP40 WLG@-RP60 Cable specifications Standard 5-m VCT cable. Finished outer diameter: 11.5 mm, 4 conductors. Standard 5-m VCT cable, with high flexibility and good anti-oil properties attached. Finished outer diameter: 11.5 mm, 4 conductors. Connector specifications Resin cap Metal connector Resin connector *2 Resin cap *2. The connector can be removed, so it is possible to use flexible conduit for the cable. 41 WL-N/WL Spatter-prevention Switches: WLCA2-LES-N Basic Switches Actuator Roller, Roller Axis Using stainless steel prevents spatter from adhering. Operating Lever A baking finish is applied to the surface so that any adhering spatter is easily removed. Roller Lever Bolt Stainless steel construction to prevent spatter adherence. Double nut models are also available. Screws Externally visible screws on the head and cover are made of stainless steel to prevent spatter adherence. Head Cap Using fluororesin prevents spatter from adhering. * Spatter means the zinc powder produced when welding. Adhering spatter to the Limit Switch may cause malfunction of lever or lamp cover. The lack of gap prevents spatter powder from clogging. Spatter-prevention Switches: WLG2-LEAS High-sensitivity and High-precision Switches Actuator Roller, Roller Axis Using stainless steel prevents spatter from adhering. Operating Lever A baking finish is applied to the surface so that any adhering spatter is easily removed. Double Nut SUS is used for double nut. Lamp Cover · Heat-resistant resin is used for the lamp cover. · By using spherical surface for the display part, it disperses the direction of spatter. 42 Screws Externally visible screws on the head and cover are made of stainless steel to prevent spatter adherence. Head Cap Using fluororesin prevents spatter from adhering. * Spatter means the zinc powder produced when welding. Adhering spatter to the Limit Switch may cause malfunction of lever or lamp cover. The lack of gap prevents spatter powder from clogging. WL-N/WL Long-life Switches: WLMCA2-N Basic Switches Head Cap Head The head cap helps prevent the entry of cutting chips.You can use the protrusion on the cap to confirm the set position. You can remove the two screws to mount the head in any of the four possible directions. Actuator Shield Structure Roller A head cap and oil seal form a double-seal structure. Excellent durability and reliability are ensured. The roller is made of self-lubricating sintered stainless steel. It provides superior resistance to wear. Lever The lever is forged from anti-corrosive aluminum alloy. It provides superior corrosion resistance and outstanding strength. With a roller lever actuator, the actuator position can be set anywhere within 360°. (The lever cannot be mounted in the opposite direction.) Oil seal Head cap Operating Plunger PEEK resin is used. It provides superior resistance to wear. You can change the mounting direction to use any one of the three operating directions (both sides, left side, or right side). Built-in Switch Built-in switch with an SPST-NO+NC contact form. Cover Seal High sealing performance is achieved. The seal also serves as a spacer. There is no troublesome insulating paper, making it easy to work with the Switch. Terminal Screws Four, M3.5 screws. Cover Setscrew Conduit Opening In addition to parallel threads for G1/2 tubing, direct-wired and pre-wired connector types are available. Cover A combination Philips-slotted screw is used. A retainer prevents the screw from falling from the cover even when the screw is loose. 43 WL-N/WL Long-life Switches: WLMG2 High-sensitivity/High-precision Switches Release Plunger Set Position Marker Plate The set position is easy to view. Hardening method changed for greater abrasion resistance. The stroke is indicated in fluorescent color that is visible from the slit in the rubber cap. Long-life Model Standard Model Stainless steel + Hardening Sintered alloy Head The Head can be mounted in any of the four directions by removing the screws at the four corners of the Head. Fluorescent paint Shaft Section Seal Requires maintenance (excessive overtravel) Proper range Requires maintenance (insufficient overtravel) Proper range By fitting a double seal consisting of an oil seal and an X-ring to the rotary shaft, even greater sealing properties are achieved. Requires maintenance (excessive overtravel) Actuator Oil seal Head Mounting Screws X-ring Roller The roller is made of self-lubricating stainless sintered and boasts high resistance to wear. Lever Smoother Movement A grease holder is provided on the shaft to prevent the grease from running out. The lever forged of anti-corrosive aluminium alloy features high corrosion resistance and outstanding ruggedness. With roller lever models, the actuator position can be set anywhere within 360°. (The lever cannot be mounted in the opposite direction.) Standard Model Operational Plunger * Cover Seal By using a packing seal as the cover seal, an optimum squeeze can be obtained and high sealing properties are assured as well. Long-life Model Terminal Screws Grease holder Four, M4 screws Smooth movement is achieved using olefin grease. (Standard models use molybdenum disulfide grease.) Cover Separator Bearing The separator has outstanding insulation properties and prevents the generation of any gases which may corrode the internal parts. The bearing smooths the plunger movement. Built-in Switch Built-in switch with SPST-NO+NC contact form. Cover Mounting Screw Conduit Opening In addition to parallel threads for G½ tubing, direct-wired and pre-wired connector types are available. 44 Phillips screws are used to ensure ease of use. WL-N/WL Dimensions and Operating Characteristics (Unit: mm) General-purpose and Environment-resistant Switches Standard Switches Switches with Roller Lever Actuators Basic Switches Roller lever R38 Roller lever R50 WLCA2-N WLCA2-2-N WLCA2-2N-N WLCA2-7-N 17.5×7 dia. * 60 max. 53±1.5 41.5±1.5 40±1.5 25.4 13.1 17.5×15 dia. * 12.7 Two, M3.5 Two, M3.5 R50 R38 (125) 14.7 12.7 (137) 14.7 68.7 Three, M4 21.6 (15.1) 30.2±0.2 40±0.7 JIS B 0202 G½ 29.2±1.2 42 max. 53.2±0.8 68.7 58.7±0.2 5 (4.9) Three, M4 5 Four, M6 Depth: 15 min. (4.9) 21.6 (15.1) Adjustable roller lever WLCA2-8-N WLCA12-N WLCA12-2-N WLCA12-2N-N 60 max. 53±1.5 41.5±1.5 40±1.5 17.5×7 dia. * 17.5×7 dia. * 25.4 13.1 R63 Two, M3.5 Two, M3.5 Adjustable range: 25 to 89 12.7 M5 Allen-head bolt Four, 5.2 dia. holes 58.7±0.2 68.7 5 (4.9) JIS B 0202 G½ 40±0.7 29.2±1.2 42 max. 53.2±0.8 Four, M6 Depth: 15 min * Stainless sintered roller 25.4 M5 Allen-head bolt 58.7±0.2 21.6 41.5±1.5 25.4 13.1 12.7 14.7 Three, M4 (15.1) 30.2±0.2 Four, M6 Depth: 15 min 67 max. 60±1.5 Four, 5.2 dia. holes 25.4 5 (4.9) 29.2±1.2 42 max. 53.2±0.8 * Stainless sintered roller Roller lever R63 14.7 JIS B 0202 G½ 30.2±0.2 40±0.7 * Stainless sintered roller (150) 25.4 M5 Allen-head bolt Four, 5.2 dia. holes 58.7±0.2 25.4 13.1 Four, 5.2 dia. holes 25.4 M5 Allen-head bolt 67.2 max. 58.1±1.5 41.5±1.5 36±1.5 68.7 Three, M4 (15.1) 30.2±0.2 40±0.7 JIS B 0202 G½ 21.6 29.2±1.2 42 max. 65.2±0.8 Four, M6 Depth: 15 min * Stainless sintered roller Note: Unless otherwise indicated, a tolerance of ±0.4 mm applies to all dimensions. Model Operating characteristics Operating force Release force Pretravel Overtravel Movement Differential OF RF PT OT MD max. min. min. max. Model Operating characteristics Operating force Release force Pretravel Overtravel Movement Differential OF RF PT OT MD max. min. min. max. WLCA2-N WLCA2-2-N WLCA2-2N-N WLCA2-7-N WLCA2-8-N 13.34 N 1.18 N 15±5° 70° 12° 13.34 N 1.18 N 25±5° 60° 16° 13.34 N 1.18 N 20° max. 70° 10° 10.2 N 0.9 N 15±5° 70° 12° 8.04 N 0.71 N 15±5° 70° 12° WLCA12-N *1 WLCA12-2-N *1 WLCA12-2N-N *1 13.34 N 1.18 N 15±5° 70° 12° 13.34 N 1.18 N 25±5° 60° 16° 13.34 N 1.18 N 20° max 70° 10° * The operating characteristics are measured at the lever length of 38 mm. 45 WL-N/WL Switches with Roller Lever Actuators Basic Switches Adjustable rod lever 25 to 140 mm Adjustable rod lever WLCL-N WLCL-2-N WLCL-2N-N WLCAL4-N 67 max. 8 9 3.2 dia. * 55 max. 46±1.5 3±0.2 dia. (length:160) * Adjustable range: 25 to 140 Two, M3.5 M8 Allen-head set screw 41.5±1.5 25.4 13.1 12.7 Adjustable range: 350 to 380 12.7 65 Four, 5.2 dia. holes 25.4 M5 Allen-head set screw Three, M4 68.7 58.7±0.2 5 25.4 M5 Allen-head set screw Four, 5.2 dia. holes 14.7 14.7 58.7±0.2 54.5±1.5 12.8 41.5±1.5 25.4 13.1 68.7 Three, M4 5 (4.9) (15.1) 30.2±0.2 40±0.7 JIS B 0202 G½ (4.9) 21.6 Four, M6 Depth: 15 min. 29.2±1.2 42 max. (15.1) 30.2±0.2 40±0.7 JIS B 0202 G½ 21.6 29.2±1.2 42 max. Four, M6 Depth: 15 min. * Stainless steel rod * Stainless steel rod Rod spring lever WLCAL5-N 67 max. 7.5 2.3 dia. * 428.5±2 54.5±1.5 41.5±1.5 25.4 65 13.1 12.7 Four, 5.2 dia. holes 11 14.7 25.4 M5 Allen-head bolt 68.7 58.7±0.2 Three, M4 5 (4.9) (15.1) 30.2±0.2 40±0.7 JIS B 0202 G½ 21.6 29.2±1.2 42 max. Four, M6 Depth: 15 min. * Piano wire Note: Unless otherwise indicated, a tolerance of ±0.4 mm applies to all dimensions. Model Operating characteristics Operating force Release force Pretravel Overtravel Movement Differential OF RF PT OT MD max. min. min. max. WLCL-N *1 WLCL-2-N *1 WLCL-2N-N *1 WLCAL4-N *2 WLCAL5-N 1.39 N 0.27 N 15±5° 70° 12° 1.39 N 0.27 N 25±5° 60° 16° 1.39 N 0.27 N 20° max 70° 10° 0.98 N 0.15 N 15±5° 70° 12° 0.9 N 0.09 N 15±5° 70° 12° Note: The actuator on the WLCAL4-N and WLCAL5-N is heavy, which may result in resetting problems depending on the direction the Switch is mounted. Mount the Switch so that the actuator is facing downwards to prevent this problem from occurring. *1. The operating characteristics are measured at the lever length of 140 mm. *2. The operating characteristics are measured at a rod length of 380 mm. 46 WL-N/WL Switches with Roller Lever Actuators High-sensitivity Switches Roller lever R38 Adjustable rod lever 25 to 140 mm WLG2 WL01G2 17.5 dia. (length: 7) * 9 3 ±0.2 dia. (length: 160) * 25.4 12.7 Four, M3.5 38R WLGL WL01GL 60 max. 53 ±1.5 41.5 ±1.5 40 ±1.5 13.1 M5 (length: 12) Allen-head bolt Adjustable range: 25 to 140 Four, M3.5 14.7 68.7 58.7 ±0.2 JIS B0202 G½ (15.1) Effective thread: 30.2 ±0.2 4 threads min. 40 ±0.7 * Stainless sintered roller 21.6 Four, M6 Depth: 15 min. ±1.2 29.2 35 42 max. 53.2 ±0.8 68.7 Three, M4 (length: 13) 5 (4.9) 25.4 M5 (length: 12) Allenhead bolt Four, 5.2 +0.2 0 dia. holes 14.7 Four, 5.2 +0.2 0 dia. holes Three, M4 (length: 13) 25.4 12.7 M8 (length: 12) Allen-head lock screw 25.4 (125) 58.7 ±0.2 55 max. 46 ±1.5 41.5 ±1.5 13.1 5 (4.9) (15.1) 30.2 ±0.2 40 ±0.7 JIS B0202 G½ Effective thread: 4 threads min. 21.6 ±1.2 29.2 35 42 max. Four, M6 Depth: 15 min. * Stainless sintered roller Adjustable Roller Lever R38 WLG12 WL01G12 67 max. 60 ±1.5 41.5 ±1.5 13.1 17.5 dia. (length: 7) * 25.4 12.7 Four, M3.5 M5 (length: 16) Allen-head bolt Four, 5.2 +0.2 0 dia. holes Adjustable range: 25 to 89 14.7 58.7 ±0.2 25.4 68.7 Three, M4 (length: 13) 5 21.6 (15.1) 30.2 ±0.2 40 ±0.7 (4.9) Four, M6 Depth: 15 min. ±1.2 JIS B0202 G½ Effective thread: 4 threads min. 29.2 35 42 max. 65.2 ±0.8 * Stainless sintered roller Note: 1. Unless otherwise indicated, a tolerance of ±0.4 mm applies to all dimensions. Switches with High-precision Actuators Roller lever R38 60 max. WLGCA2 WL01GCA2 17.5 dia. (length: 7) * 25.4 12.7 Four, M3.5 38R (125) 53 ±1.5 41.5 ±1.5 40 ±1.5 13.1 M5 (length: 12) Allen-head bolt 25.4 14.7 Four, 5.2 +0.2 0 dia. holes 68.7 58.7 ±0.2 Three, M4 (length: 13) 5 (4.9) (15.1) 30.2 ±0.2 40 ±0.7 JIS B0202 G½ Effective thread: 4 threads min. * Stainless sintered roller 21.6 ±1.2 29.2 Four, M6 Depth: 15 min. 35 42 max. 53.2 ±0.8 Note: 1. Unless otherwise indicated, a tolerance of ±0.4 mm applies to all dimensions. Model Operating characteristics Operating force Release force Pretravel Overtravel Movement Differential OF RF PT OT MD max. min. min. max. WLG2 WL01G2 9.81 N 0.98 N +2° 10° −1° 65° 7° WLG12 *1 WL01G12 *1 WLGL *2 WL01GL *2 WLGCA2 WL01GCA2 9.81 N 0.98 N +2° 10° −1° 65° 7° 2.84 N 0.25 N +2° 10° −1° 65° 7° 13.34 N 1.47 N +2° 5° 0° 40° 3° *1. The operating characteristics are measured at the lever length of 38 mm. *2. The operating characteristics are measured at a rod length of 140 mm. 47 WL-N/WL Switches with Plunger Actuators Basic Switches Sealed top plunger WLD18-N Horizontal plunger 10 dia. 13.1 R1 * 12.9 PT 25.4 13.1 Two, M3.5 12.7 25 dia. *2 R1 Two, M3.5 OP 27.5 17.8 9.3 dia. *1 (96.2) Four, 5.2 dia. holes 58.7±0.2 Four, 5.2 dia. holes 58.7±0.2 68.7 68.7 Three, M4 Three, M4 5 (4.9) * Stainless steel plunger OP 46.6±0.8 PT WLSD-N (15.1) 30.2±0.2 JIS B 0202 G½ 40±0.7 21.6 29.2±1.2 42 max. Four, M6 Depth: 15 min *1. Stainless steel plunger *2. Cosmetic nuts 5 (4.9) (15.1) 30.2±0.2 JIS B 0202 G½ 40±0.7 Sealed top-roller plunger 21.6 29.2±1.2 42 max. Four, M6 Depth: 15 min Horizontal-roller plunger 13.1 WLD28-N 14.3 dia.×5 * PT WLSD2-N 12.9 PT 25.4 OP 55.7±0.8 Two, M3.5 13.1 12.7 25 dia. *2 Two, M3.5 OP 27.5 17.8 17 dia.×4.6 *1 (96.2) Four, 5.2 dia. holes 58.7±0.2 Four, 5.2 dia. holes 58.7±0.2 68.7 68.7 Three, M4 Three, M4 5 5 (4.9) *Stainless sintered roller (15.1) 30.2±0.2 JIS B 0202 G½ 40±0.7 21.6 29.2±1.2 42 max. Four, M6 Depth: 15 min (15.1) 30.2±0.2 JIS B 0202 G½ Horizontal-ball plunger 13.1 12.9 15.5 dia. 1/2" dia. * PT (4.9) 40±0.7 Sealed top-ball plunger WLD38-N *1. Stainless sintered roller *2. Cosmetic nuts WLSD3-N PT 25.4 21.6 29.2±1.2 42 max. OP 46.6±0.8 Two, M3.5 13.1 12.7 25 dia. *2 Two, M3.5 OP Four, M6 Depth: 15 min 15.5 dia. 27.5 17.8 1/2" dia. *1 (96.2) Four, 5.2 dia. holes 58.7±0.2 Four, 5.2 dia. holes 58.7±0.2 68.7 68.7 Three, M4 Three, M4 5 * Stainless steel ball (4.9) (15.1) 30.2±0.2 40±0.7 JIS B0202 G½ 21.6 29.2±1.2 42 max. Top-roller plunger WLD2-N Four, M6 Depth: 15 min * 1. Stainless steel ball * 2. Cosmetic nuts 5 (4.9) (15.1) 30.2±0.2 JIS B0202 G½ 40±0.7 21.6 29.2±1.2 42 max. Four, M6 Depth: 15 min 13.1 12.9 17 dia.×4.6 * PT Four, M3.5 OP 28.4 Four, 5.2 dia. holes 68.7 58.7±0.2 Three, M4 *Stainless sintered roller 5 (4.9) (15.1) 30.2±0.2 40±0.7 JIS B0202 G½ 21.6 29.2±1.2 42 max. Four, M6 Depth: 15 min Note: Unless otherwise indicated, a tolerance of ±0.4 mm applies to all dimensions. Model Operating characteristics 48 WLD18-N WLD28-N WLD38-N WLD2-N WLSD-N WLSD2-N WLSD3-N Operating force Release force Pretravel Overtravel Movement Differential OF RF PT OT MD max. min. max. min. max. 26.67 N 8.92 N 1.7 mm 6.4 mm 1 mm 16.67 N 4.41 N 1.7 mm 5.6 mm 1 mm 16.67 N 4.41 N 1.7 mm 5.6 mm 1 mm 26.67 N 8.92 N 1.7 mm 5.6 mm 1 mm 40.03 N 8.89 N 2.8 mm 5.6 mm 1 mm 40.03 N 8.89 N 2.8 mm 5.6 mm 1 mm 40.03 N 8.89 N 2.8 mm 4 mm 1 mm Operating position Total travel position OP TTP max. 34±0.8 mm 29.5 mm 44±0.8 mm 39.5 mm 44.5±0.8 mm 41 mm 44±0.8 mm 39.5 mm 40.6±0.8 mm --- 54.2±0.8 mm --- 54.1±0.8 mm --- WL-N/WL Switches with Flexible Rod Actuators Basic Switches Coil spring Coil Spring (Multi-wire) WLNJ-N WLNJ-30-N *1 PT *1 6.5 dia. PT *3 4.8 dia. *3 *2 *2 (107) (107) 140±2.5 140±2.5 13.1 12.9 13.1 12.9 Two, M3.5 Two, M3.5 33.7±0.8 33.7±0.8 Four, 5.2 dia. holes 58.7±0.2 Four, 5.2 dia. holes 68.7 58.7±0.2 Three, M4 5 (15.1) 30.2±0.2 (4.9) JIS B 0202 G½ 40±0.7 68.7 Three, M4 21.6 29.2±1.2 42 max. 5 Four, M6 Depth: 15 min (4.9) (15.1) 30.2±0.2 JIS B 0202 G½ 40±0.7 *1. Do not operate the Switch in the direction of the axial center. *2. Stainless steel coil spring. *3. The range for operation is 1/3rd of the overall spring length from the end of the spring. Resin rod 21.6 29.2±1.2 42 max. Four, M6 Depth: 15 min *1. Do not operate the Switch in the direction of the axial center. *2. Piano wire coil spring. *3. The range for operation is 1/3rd of the overall spring length from the end of the spring. Steel wire WLNJ-2-N WLNJ-S2-N *1 PT *1 8 dia. *3 1 dia PT *3 *2 (95.4) (159) 140±2.5 *2 193±2.5 13.1 12.9 26 dia. 13.1 12.9 Two, M3.5 44.6±0.8 Two, M3.5 33.7±0.8 Four, 5.2 dia. holes Four, 5.2 dia. holes 58.7±0.2 68.7 58.7±0.2 68.7 Three, M4 Three, M4 5 (4.9) (15.1) 30.2±0.2 JIS B0202 G½ 40±0.7 21.6 29.2±1.2 42 max. 5 Four, M6 Depth: 15 min (4.9) (15.1) 30.2±0.2 JIS B 0202 G½ 40±0.7 *1. Do not operate the Switch in the direction of the axial center. *2. Polyamide Resin Rod *3. The range for operation is 1/3rd of the overall rod length from the end of the rod. 21.6 29.2±1.2 42 max. Four, M6 Depth: 15 min *1. Do not operate the Switch in the direction of the axial center. *2. Stainless steel wire. *3. The range for operation is 1/3rd of the overall wire length from the end of the wire. Note: Unless otherwise indicated, a tolerance of ±0.4 mm applies to all dimensions. Model Operating characteristics Operating force Pretravel OF PT max. WLNJ-N WLNJ-30-N WLNJ-2-N WLNJ-S2-N 1.47 N 20±10 mm 1.47 N 20±10 mm 1.47 N 40±20 mm 0.28 N 40±20 mm * These values are for the top end of the spring, rod, or wire. 49 WL-N/WL Switches with Fork Lock Lever Actuators Retention Switches General-purpose WLCA32-41-N WLCA32-42-N WLCA32-43-N WLCA32-44-N The WLCA32-41-N is shown in the following diagram. Two, 17.5×7 dia. * 90°±3° 62.5 max. 56.4±3.5 42.8±3.5 25.4 13.1 12.7 R38 Two, M3.5 14.7 34.1 M5 Allen-head set screw Four, 5.2 dia. holes Three, M4 (125) 58.7±0.2 68.7 5 (15.1) 21.6 JIS B 0202 G½ (4.9) 30.2±0.2 29.2±1.2 40±0.7 42 max. 4-M6 Four, M6 Depth: 15 min. * Plastic Roller (The WLCA32-041-N to WLCA32-044-N have stainless steel rollers.) Note: 1. Unless otherwise indicated, a tolerance of ±0.4 mm applies to all dimensions. Model Operating characteristics Force necessary to reverse the direction of the lever Movement until the lever reverses Movement until switch operation Movement after switch operation WLCA32-41 to 44-N max. 11.77N 50±5° 55° 35° max. min. Operation indicator Switches Switches with Roller Lever Actuators Basic Switches Roller lever R38 General-purpose Models WLCA2-LD-N WLCA2-LE-N 60 max. 53±1.5 41.5±1.5 40±1.5 25.4 13.1 12.7 17.5×7 dia. * Two, M3.5 R38 Four, 5.2 dia. holes 25.4 (125) 14.7 M5 Allen-head bolt 58.7±0.2 68.7 Three, M4 5 21.6 (4.9) (15.1) JIS B 0202 G½ 30.2±0.2 40±0.7 29.2±1.5 Four, M6 42 max. Depth: 15 min 53.2±0.8 * Stainless sintered roller Note: Unless otherwise indicated, a tolerance of ±0.4 mm applies to all dimensions. Operating characteristics Operating force Release force Pretravel Overtravel Movement Differential 50 Basic models OF RF PT OT MD max. min. min. max. 13.34 N 1.18 N 15±5° 70° 12° WL-N/WL Sensor I/O Connector Switches (For details about applicable cables, refer to Connecting Sensor I/O Connectors Cable and Socket on page 22.) Switches with Roller Lever Actuators Basic Switches Roller lever R38 Pre-wired Connector type Roller lever R38 Direct-wire Connector type WLCA2-LD-M1J-N WLCA2-LDK13-N 60 max. 53±1.5 41.5±1.5 40±1.5 25.4 13.1 12.7 17.5×7 dia. * Two, M3.5 17.5×7 dia. * Two, M3.5 R38 25.4 M5 Allen-head bolt (125) Four, 5.2 dia. holes M5 Allen-head bolt 14.7 (125) 25.4 58.7±0.2 68.7 58.7±0.2 (4.9) (15.1) 5 12.5 30.2±0.2 M12×1 40±0.7 Four, M6 Depth: 15 min SC-1M 300 +100 −50 Four, M6 Depth: 15 min. 29.2±1.2 42 max. 53.2±0.8 68.7 Three, M4 5 Three, M4 (15.1) 12.7 Four, 5.2 dia. holes 14.7 R38 (4.9) 60 max. 53±1.5 41.5±1.5 40±1.5 25.4 13.1 XS2H-D421 * Stainless sintered roller 30.2±0.2 40±0.7 29.2±1.2 42 max. 53.2±0.8 * Stainless sintered roller Note: 1. Unless otherwise indicated, a tolerance of ±0.4 mm applies to all dimensions. 2. The models with operation indicators are shown in the above diagrams. Operating characteristics Operating force Release force Pretravel Overtravel Movement Differential Basic models OF RF PT OT MD max. min. 13.34 N 1.18 N 15±5° 70° 12° min. max. High-sensitivity and High-precision Switches Roller lever R38 Direct-wire Connector type High-sensitivity WLG2 High-precision WLGCA2 53 ±1.5 41.5 ±1.5 40 ±1.5 13.1 17.5 dia. (length: 7) * 68.7 Three, M4 (length: 13) 5 68.7 (20) +100 300 -50 ±1.2 JIS B0202 G½ Effective thread: 4 threads min. Four, M6 Depth: 15 min. SC-1M Four, M6 21.6 Depth: 15 min. M12 × 1 * Stainless sintered roller 25.4 58.7 ±0.2 5 12.5 (4.9) 25.4 12.7 Four, 5.2 +0.2 0 dia. holes Three, M4 (length: 13) (15.1) 30.2 ±0.2 40 ±0.7 Four, M3.5 60 max. 53 ±1.5 41.5 ±1.5 40 ±1.5 13.1 M5 (length: 12) Allen-head bolt 25.4 Four, 5.2 +0.2 0 dia. holes 58.7 ±0.2 38R 14.7 M5 (length: 12) Allen-head bolt 14.7 17.5 dia. (length: 7) * High-sensitivity WLG2 High-precision WLGCA2 25.4 12.7 Four, M3.5 38R Roller lever R38 Pre-wired Connector type 60 max. 29.2 35 42 max. 6 dia. 53.2 ±0.8 (4.9) (15.1) 30.2 ±0.2 40 ±0.7 XS2H-D421 M12 × 1 * Stainless sintered roller 21.6 ±1.2 29.2 35 42 max. 53.2 ±0.8 Note: Unless otherwise indicated, a tolerance of ±0.4 mm applies to all dimensions. Operating characteristics Operating force Release force Pretravel Overtravel Movement Differential OF RF PT OT MD max. min. min. max. High-sensitivity High-precision Models 9.81 N 0.98 N +2° 10° −1° 65° 7° 13.34 N 1.47 N +2° 5° 0° 40° 3° 51 WL-N/WL Spatter-prevention Switches Switches with Roller Lever Actuators Basic Switches Roller lever R38 Screw terminal type Roller lever R38 Pre-wired Connector type WLCA2-@S-N 17.5×7 dia. * Two, M3.5 R38 WLCA2-@S-M1J-1-N 60 max. 53±1.5 41.5±1.5 40±1.5 25.4 13.1 12.7 60 max. 53±1.5 41.5±1.5 40±1.5 25.4 13.1 17.5×7 dia. * Two, M3.5 R38 Four, 5.2 dia. holes 12.7 Four, 5.2 dia. holes 25.4 (125) 14.7 58.7±0.2 25.4 M5 Allen-head bolt 14.7 M5 Allen-head bolt Fluorine resin cap Three, M4 (125) 58.7±0.2 68.7 5 Three, M4 Fluorine resin cap 68.7 5 (4.9) (15.1) 30.2±0.2 40±0.7 JIS B 0202 G½ 21.6 29.2±1.2 42 max. 53.2±0.8 (4.9) (15.1) Four, M6 Depth: 15 min Four, M6 Depth: 15 min SC-1M 300 +100 −50 * Stainless sintered roller XS2H-D421 29.2±1.2 30.2±0.2 40±0.7 42 max. 53.2±0.8 * Stainless sintered roller Note: 1. Unless otherwise indicated, a tolerance of ±0.4 mm applies to all dimensions. 2. The models with operation indicators are shown in the above diagrams. High-sensitivity/High-precision Switches Roller lever R38 Screw terminal type Roller lever R38 Pre-wired Connector type WLG2-@S WLGCA2-@S WLG2-@S-M1J * WLGCA2-@S-M1J * * External dimensions are the same even for different core wires. 17.5 dia. (length: 7) * Four, M3.5 head clamping screws 38R 25.4 Four, 5.2 +0.2 0 dia. holes Fluororesin cap 14.7 17.5 dia. (length: 7) * 25.4 12.7 Two, M5 Allen-head nut and arm set screw 38R (125) 60 max. 54 ±1.5 13.1 Four, M3.5 head clamping screws Two, M5 Allen-head nut and arm set screw 60 max. 53 ±1.5 41.5 ±1.5 40 ±1.5 13.1 25.4 12.7 25.4 Four, 5.2 +0.2 0 dia. holes 14.7 Fluororesin cap 68.7 Three, M4 (length: 13) 58.7 ±0.2 68.7 58.7 ±0.2 Lamp cover Lamp cover 5 5 Three, M4 (length: 13) (4.9) (15.1) 30.2 ±0.2 40 ±0.7 21.6 JIS B0202 G½ Effective thread: 4 threads min. ±1.2 29.2 (20) Four, M6 Depth: 15 min. Four, M6 Depth: 15 min. 35 42 max. SC-1M 300 +100 −50 * Stainless steel roller 6 dia. (4.9) (15.1) 30.2 ±0.2 40 ±0.7 XS2H-D421 * Stainless steel roller Note: Unless otherwise indicated, a tolerance of ±0.4 mm applies to all dimensions. Operating characteristics Operating force Release force Pretravel Overtravel Movement Differential 52 OF RF PT OT MD max. min. min. max. Basic models High-sensitivity High-precision Models 13.34 N 1.18 N 15±5° 70° 12° 9.81 N 0.98 N +2° 10° −1° 65° 7° 13.34 N 1.47 N +2° 5° 0° 40° 3° 21.6 ±1.2 29.2 35 42 max. 53.2 ±0.8 WL-N/WL Switches with Plunger Actuators Basic Switches Sealed top-roller plunger Screw terminal type Sealed top-roller plunger Pre-wired Connector type WLD28-@S-N WLD28-@S-M1J-1-N 14.3 dia.×5 * PT 13.1 12.9 Rubber cap (fluorine rubber) 14.3 dia.×5 * Rubber cap (fluorine rubber) 13.1 12.9 Two, M3.5 OP Two, M3.5 OP PT Four, 5.2 dia. holes Four, 5.2 dia. holes 58.7±0.2 58.7±0.2 68.7 68.7 Three, M4 Three, M4 5 5 (15.1) 21.6 JIS B 0202 G½ (4.9) 30.2±0.2 29.2±1.2 40±0.7 42 max. Four, M6 Depth: 15 min 300 *Stainless sintered roller Four, M6 Depth: 15 min SC-1M +100 −50 XS2H-D421 (15.1) 29.2±1.2 (4.9) 30.2±0.2 42 max. 40±0.7 *Stainless sintered roller Note: 1. Unless otherwise indicated, a tolerance of ±0.4 mm applies to all dimensions. 2. The models with operation indicators are shown in the above diagrams. Operating characteristics Basic models Operating force Release force Pretravel Overtravel Movement Differential OF RF PT OT MD max. min. Operating force Pretravel OF PT max. min. max. 16.67 N 4.41 N 1.7 mm max. 5.6 mm 1 mm 44±0.8 mm 39.5 mm 53 WL-N/WL Long-life Switches Switches with Roller Lever Actuators Basic Switches Roller lever R38 Screw terminal type Roller lever R38 Direct-wire Connector type WLMCA2-LD-N 60 max. 53±1.5 41.5±1.5 40±1.5 25.4 17.5 dia.×7 * WLMCA2-LDK13-N 17.5 dia.×7 * 13.1 12.7 Two, M3.5 R38 Four, 5.2 dia. holes 25.4 14.7 Fluorine resin cap Fluorine resin cap 68.7 58.7±0.2 68.7 Three, M4 Three, M4 5 12.5 21.6 (15.1) Four, M6 Depth: 15 min (4.9) 30.2±0.2 29.2±1.2 JIS B 0202 G½ *Stainless sintered roller Roller lever R38 Pre-wired Connector type 60 max. 53±1.5 41.5±1.5 40±1.5 25.4 WLMCA2-LD-M1J-N 17.5 dia.×7 * 13.1 12.7 Two, M3.5 Four, 5.2 dia. holes 25.4 M5 Allen-head bolt Fluorine resin cap 58.7±0.2 68.7 Three, M4 5 Four, M6 Depth: 15 min SC-1M 300 +100 −50 XS2H-D421 (15.1) 29.2±1.2 (4.9) 42 max. 30.2±0.2 40±0.7 53.2±0.8 *Stainless sintered roller Note: 1. Unless otherwise indicated, a tolerance of ±0.4 mm applies to all dimensions. 2. The models with operation indicators are shown in the above diagrams. Operating characteristics Operating force Release force Pretravel Overtravel Movement Differential 54 Basic models OF RF PT OT MD max. min. min. max. 29.2±1.2 40±0.7 *Stainless sintered roller 13.34 N 1.18 N 15±5° 70° 12° Four, M6 Depth: 15 min M12×1 30.2±0.2 53.2±0.8 14.7 (15.1) (4.9) 42 max. 40±0.7 R38 25.4 M5 Allen-head bolt M5 Allen-head bolt 58.7±0.2 5 13.1 12.7 Two, M3.5 R38 Four, 5.2 dia. holes 14.7 60 max. 53±1.5 41.5±1.5 40±1.5 25.4 42 max. 53.2±0.8 WL-N/WL Switches with Roller Lever Actuators High-sensitivity and High-precision Switches Roller lever R38 Screw terminal type Roller lever R38 Direct-wire Connector type 60 max. 53 ±1.5 WLMG@-LD 38R 17.5 dia. (length: 7) * Four, M3.5 (length: 26.5) M5 (length: 12) Allen-head bolt WLMG@-LD@ 41.5 ±1.5 40 ±1.5 13.1 17.5 dia. (length: 7) * 25.4 12.7 Four, M3.5 (length: 26.5) 38R 25.4 Four, 5.2 +0.2 0 dia. holes 14.7 60 max. 53 ±1.5 14.7 Rubber cap 58.7 ±0.2 58.7 ±0.2 Lamp cover 21.6 ±1.2 (15.1) 30.2 ±0.2 40 ±0.7 (4.9) 29.2 * Stainless sintered roller JIS B0202 G½ Effective thread: 4 threads min. Four, M6 Depth: 15 min. 35 42 max. WLMG@-LD@ 17.5 dia. (length: 7) * 68.7 Lamp cover SC-2FD (15.1) 30.2 ±0.2 40 ±0.7 * Stainless sintered roller Four, M6 21.6 Depth: 15 min. ±1.2 M12 x 1 JIS B0202 G½ Effective thread: 4 threads min. 29.2 35 42 max. 53.2 ±0.8 25.4 12.7 25.4 Four, 5.2 +0.2 0 dia. holes 14.7 25.4 60 max. 53 ±1.5 41.5 ±1.5 40 ±1.5 13.1 Four, M3.5 (length: 26.5) M5 (length: 12) Allen-head bolt 38R M5 (length: 12) Allen-head bolt Four, 5.2 +0.2 0 dia. holes Three, M4 (length: 13) 5 12.5 (4.9) 53.2 ±0.8 Roller lever R38 Pre-wired Connector type 25.4 12.7 Rubber cap 68.7 Three, M4 (length: 13) 5 41.5 ±1.5 40 ±1.5 13.1 Rubber cap Three, M4 (length: 13) 58.7 ±0.2 68.7 Lamp cover (20) Four, M6 Depth: 15 min. 5 XS2H-D421 300 +100 -50 44.7 6 dia. 21.6 (15.1) 30.2 ±0.2 40 ±0.7 (4.9) ±1.2 29.2 35 42 max. 53.2 ±0.8 * Stainless sintered roller Note: Unless otherwise indicated, a tolerance of ±0.4 mm applies to all dimensions. Operating characteristics Operating force Release force Pretravel Overtravel Movement Differential OF RF PT OT MD max. min. min. max. High-sensitivity High-precision Models 9.81 N 0.98 N +2° 10° −1° 65° 7° 13.34 N 1.47 N +2° 5° 0° 40° 3° 55 WL-N/WL Actuators (Levers Only) Lever: Only rotating lever models are illustrated. WL-1A100 Standard Lever WL-1A115 Resin Roller 17.9 17.5 dia. × 7, sintered stainless steel roller 7.3-dia. mounting holes 12.6 WL-1A105 Double Nuts WL-1A103S Spatter Prevention 17.9 17.5 dia. × 7, sintered stainless steel roller 7.3-dia. mounting holes 12.6 Two, M5 Allenhead nut 11.4 and arm set screw 38 12.1 7.3-dia. mounting 16 holes M5 Allen-head bolt 11.4 16 17.9 7.3-dia. mounting holes 54.8 24.9±0.8 19.7±0.8 17.5 dia. × 7, sintered stainless steel roller 7.3-dia. mounting holes 63 M5 Allen-head bolt 11.4 Adjustable lever: stainless steel WL-2A107 Double Nuts 24.9±0.8 19.7±0.8 17.5 dia. (length: 7) resin roller Adjustable lever: stainless steel Adjustable range: 25 to 89 105.75 17.5 dia. × 7, 24.9±0.8 sintered stainless M5 steel roller Allen-head 19.7±0.8 bolt Adjustable lever: stainless steel 7.3-dia. mounting holes M5 Allen-head bolt 12 16 105.75 12 16 12 16 M5 Allen-head bolt 11.4 17.5 dia. (length: 7) resin roller Adjustable lever: stainless steel 24.9±0.8 M5 Allen-head 19.7±0.8 bolt 23 7.3-dia. mounting holes 7.3-dia. mounting holes M5 Allen-head bolt 79.8 Adjustable range: 25 to 140 23 Adjustable range: 25 to 89 105.75 7.3-dia. mounting holes 12.6 WL-2A108 Resin Roller 23 23 Adjustable range: 25 to 89 17.9 50 66.8 16 WL-2A111 Resin Roller M5 Allen-head bolt 11.4 17.5 dia. × 7, sintered stainless steel roller 25.7 16.6 16 WL-2A100 23.6 WL-1A300 Lever Length: 63 17.5 dia. × 15, sintered stainless steel roller 12.6 40.2±0.8 54.8 38 38 54.8 M5 Allen-head bolt 11.4 16 17.5 dia. (length: 30) Nylon roller 16.9 WL-1A200 Lever Length: 50 Roller Width: 15 17.5 dia. (length: 7) stainless steel roller 7.3-dia. mounting holes 38 54.8 16 7.3-dia. mounting holes M5 Allen-head bolt 11.4 16 WL-1A118 Nylon Roller: Roller Width: 30 mm 17 dia. (length: 6) bearing roller 12.6 38 54.8 M5 Allen-head bolt 11.4 16 17.9 17.5 dia. (length: 7) resin roller 7.3-dia. mounting holes 38 54.8 WL-1A400 Bearing Roller 155.75 Two, M5 Allen-head nut and arm set screw 6.2 (15.8) WL-2A122 WL-2A106 17.5 dia. × 7, M5 sintered stainless Allen-head steel roller bolt Adjustable lever: stainless steel 24.9±0.8 19.7±0.8 23 Adjustable range: 25 to 140 7.3-dia. mounting holes WL-2A130 9.1 24.9±0.8 19.7±0.8 50 dia. (length: 6) Nylon roller 3 (21.8) 23 Adjustable range: 25 to 89 (10) R89.5 (10) 105.75 155.75 Adjustable from 42 to 89 Three, 5.3 +0.2 0 dia. holes 7.3 dia. mounting holes (112) M5 Allen-head bolt 16 20 15.9 * Can be installed on the rear side. (15.8) Note: Unless otherwise indicated, a tolerance of ±0.4 mm applies to all dimensions. 56 24.7±0.8 19.5±0.8 17.5 dia. × 7, sintered stainless steel roller Adjustable lever: stainless steel 7.3-dia. mounting holes 6.2 24.9±0.8 19.7±0.8 17.5 dia. × 7, sintered stainless steel roller WL-2A104 7.3-dia. mounting holes M5 Allen-head bolt 23 20 M5 Allen-head bolt 12 16 23 WL-N/WL Lever: Only rotating lever models are illustrated. WL-2A110 WL-2A105 WL-1A106 WL-1A110 34.2 34.5 50 dia. (length: 15) Nylon roller 24.2 49 dia. rubber roller Material: NBR 24.4 50 dia. (length: 6) Nylon roller 6 35 dia. (length: 6) Nylon roller 20.1±0.8 20.1±0.8 R38 Adjustable from 41 to 78.5 23 122 M5 Allen-head bolt 7.3-dia. mounting holes R38 23 Adjustable from 41 to 89 M5 Allen-head bolt 16 M5 Allen-head bolt 7.3-dia. mounting holes 7.3 dia. mounting holes 16 11.5 11.5 M5 Allen-head bolt 7.3-dia. mounting holes 16 16 WL-4A100 WL-4A201 9 9 3-dia. stainless steel rod 7.3-dia. mounting holes M5 Allen-head bolt Adjustable from 25 to 140 160 WL-3A100 3.2-dia. stainless steel rod 2-dia. stainless steel for spring 13 Adjustable from 270 to 290 Adjustable from 350 to 380 7.3-dia. mounting holes M8 Allen-head set screw 3.2-dia. stainless steel rod Adjustable from 350 to 380 8 400±2 M5 Allen-head bolt 19 WL-3A106 Double Nut 400±2 Actuator's center of rotation M8 Allen-head set screw 8 M5 Allen-head bolt 11 65±2 7.5 6 11 65±2 7.5 6 11 7.3-dia. mounting 12.8 holes 11 WL-3A108 WL-3A200 WL-3A203 2.3-dia. operation rod 3.2-dia. stainless steel rod M5 13.4 Allen-head bolt 25.5 max. 7.3-dia. mounting 12.8 holes 9 8 dia. Cap Adjustable up to 141 417.5±2 8 437.5±2 450±4 680±0.4 Adhesive 7.3-dia. mounting 12.8 holes M5 Allen-head bolt 7.3-dia. mounting holes 7.5 25.5 max. WL-2A129 15.8 Marking (95) 11 7.5 6 13.4 WL-5A101 6.7 17.7 12.4 84 95.3 (108) 7.3 dia. 7.3 dia. mounting hole 10 15.9 20 M5 Allen-head bolt 22.1 13 24.6 max. WL-5A105 Two, 17.5 dia. × 7, sintered stainless steel rollers Two, 17.5 dia. × 7, sintered stainless steel rollers 17.7 6.7 12.4 1.3 11 WL-5A100 has a plastic roller 17.7 12.4 90° 7.3 dia. R38 54.8 M5 Allen-head bolt 10 11.3 11 90° 90° Three, 5.2 dia. holes 7.3-dia. M5 mounting 7.5 Allen-head holes bolt WL-5A103 1.3 (18.5) M8 Allen-head set screw 11 7.5 6 M5 13 Allen-head bolt 24.6 max. Two, 17.5 dia. × 7, sintered stainless steel rollers 3 R8 19 12.5 dia. max. 2.3 dia. rod (95) 11 65±2 7.5 6 4-dia. stainless steel rod 7.3-dia. mounting holes M5 Allen-head bolt 160±1.5 470±4 12.5 dia. max. 13.4 25.5 max. WL-4A112 50 Adjustable from 650 to 660 Two, M5 Allenhead nut and arm set screw 7.3 dia. R38 54.8 M5 Allen-head bolt 11 WL-5A102 has a plastic roller R38 54.8 M5 Allen-head bolt 11 WL-5A104 has a plastic roller Note: 1. Unless otherwise indicated, a tolerance of ±0.4 mm applies to all dimensions. 2. When using the adjustable roller (rod) lever, make sure that the lever is facing downwards. Use caution, as telegraphing (the Switch turns ON and OFF repeatedly due to inertia) may occur. 57 WL-N/WL Model Replacement Table (Replacing WL Basic Models with WL-N Basic Models) Manufacturing of the basic WL models is scheduled to be discontinued. Use the following table to find the corresponding WL-N-series models and order them instead. WL WL-N WL WL-N WLCA2 WLCA2-N WLNJ WL01CA2 WLCA2-N WL01NJ WLH2 WLCA2-N WLNJ-30 WLNJ-30-N WLD28-LD WLD28-LD-N WLCA2-N WL01NJ-30 WLNJ-30-N WLSD-LE WLSD-LE-N WLCA2-2 WLCA2-2-N WLNJ-2 WLNJ-2-N WLSD-LD WLSD-LD-N WL01CA2-2 WLCA2-2-N WL01NJ-2 WLNJ-2-N WLSD2-LE WLSD2-LE-N WLCA2-2N WLCA2-2N-N WLNJ-S2 WLNJ-S2-N WLSD2-LD WLSD2-LD-N WL01CA2-2N WLCA2-2N-N WL01NJ-S2 WLNJ-S2-N WLSD3-LE WLSD3-LE-N WLCA2-7 WLCA2-7-N WLCA2-LE WLCA2-LE-N WLSD3-LD WLSD3-LD-N WL01CA2-7 WLCA2-7-N WLCA2-LD WLCA2-LD-N WLNJ-LE WLNJ-LE-N WLCA2-8 WLCA2-8-N WLH2-LE WLCA2-LE-N WLNJ-LD WLNJ-LD-N WL01CA2-8 WLCA2-8-N WLH2-LD WLCA2-LD-N WLNJ-30LE WLNJ-30LE-N WLCA12 WLCA12-N WLCA2-2LE WLCA2-2LE-N WLNJ-30LD WLNJ-30LD-N WL01CA12 WLCA12-N WLCA2-2LD WLCA2-2LD-N WLNJ-2LE WLNJ-2LE-N WLH12 WLCA12-N WLCA2-2NLE WLCA2-2NLE-N WLNJ-2LD WLNJ-2LD-N WL01H12 WLCA12-N WLCA2-2NLD WLCA2-2NLD-N WLNJ-S2LE WLNJ-S2LE-N WLCA12-2-N WLCA2-7LE WLCA2-7LE-N WLNJ-S2LD WLNJ-S2LD-N WL01CA12-2 WLCA12-2-N WLCA2-7LD WLCA2-7LD-N WLCA2-LDK13 WLCA2-LDK13-N WLCA12-2N WLCA12-2N-N WLCA2-8LE WLCA2-8LE-N WLCA2-55LDK13 WLCA2-55LDK13-N WL01CA12-2N WLCA12-2N-N WLCA2-8LD WLCA2-8LD-N WLCA2-LDK43 WLCA2-LDK43-N WLCL WLCL-N WLCA12-LE WLCA12-LE-N WLCA2-55LDK43 WLCA2-55LDK43-N WL01CL WLCL-N WLCA12-LD WLCA12-LD-N WLD2-LDK13 WLD28-LDK13-N WLHL WLCL-2N-N WLH12-LE WLCA12-LE-N WLD2-55LDK13 WLD28-55LDK13-N WL01HL WLCL-2N-N WLH12-LD WLCA12-LD-N WLD2-LDK43 WLD28-LDK43-N WLCL-2-N WLCA12-2LE WLCA12-2LE-N WLD2-55LDK43 WLD28-55LDK43-N WLCL-2N WLCL-2N-N WLCA12-2LD WLCA12-2LD-N WLH2-LDK13 WLCA2-LDK13-N WL01CL-2N WLCL-2N-N WLCA12-2NLE WLCA12-2NLE-N WLH2-55LDK13 WLCA2-55LDK13-N WLHAL4 WLCAL4-N WLCA12-2NLD WLCA12-2NLD-N WLH2-LDK43 WLCA2-LDK43-N WLHAL5 WLCAL5-N WLCL-LE WLCL-LE-N WLH2-55LDK43 WLCA2-55LDK43-N WLCA32-41 WLCA32-41-N WLCL-LD WLCL-LD-N WLCA2-55LD-M1J WLCA2-55LD-M1J-N WL01CA32-41 WLCA32-41-N WLHL-LE WLCL-2NLE-N WLCA2-LD-M1GJ WLCA2-LD-M1GJ-N WLCA32-42 WLCA32-42-N WLHL-LD WLCL-2NLD-N WLCA2-55LD-M1GJ WLCA2-55LD-M1GJ-N WLCA32-43-N WLCL-2LE WLCL-2LE-N WLCA2-55LD-M1JB WLCA2-55LD-M1JB-N WL01CA32-43 WLCA32-43-N WLCL-2LD WLCL-2LD-N WLCA2-LD-DGJ03 WLCA2-LD-DGJ-N WLCA32-44 WLCA32-44-N WLCL-2NLE WLCL-2NLE-N WLCA2-55LD-DGJ03 WLCA2-55LD-DGJ-N WLCL-2NLD-N WLCA2-LD-DK1EJ03 WLCA2-LD-DK1EJ-N WL01H2 WLCA12-2 WLCL-2 WLCA32-43 WLNJ-N WLD3-LD WLD38-LD-N WLNJ-N WLD28-LE WLD28-LE-N WLCA32-44-N WLCL-2NLD WLD WLD18-N WLHAL4-LE WLCAL4-LE-N WLCA2-55LD-DK1EJ03 WLCA2-55LD-DK1EJ-N WL01D WLD18-N WLHAL4-LD WLCAL4-LD-N WLD2-LD-M1J WLD28-LD-M1J-N WLD2 WLD28-N WLHAL5-LE WLCAL5-LE-N WLD2-55LD-M1J WLD28-55LD-M1J-N WL01D2 WLD28-N WLHAL5-LD WLCAL5-LD-N WLD2-LD-M1GJ WLD28-LD-M1GJ-N WLCA32-41LE-N WLD2-55LD-M1GJ WLD28-55LD-M1GJ-N WL01CA32-44 WLD3 WLD38-N WLCA32-41LE WL01D3 WLD38-N WLCA32-41LD WLCA32-41LD-N WLD2-55LD-M1JB WLD28-55LD-M1JB-N WLD28 WLD28-N WLCA32-42LE WLCA32-42LE-N WLD2-LD-DGJ03 WLD28-LD-DGJ-N WLD28-N WLCA32-43LE WLCA32-43LE-N WLD2-LD-DK1EJ03 WLD28-LD-DK1EJ-N WLSD WLSD-N WLCA32-43LD WLCA32-43LD-N WLD2-55LD-DK1EJ03 WLD28-55LD-DK1EJ-N WL01SD WLSD-N WLD-LE WLD18-LE-N WLH2-LD-M1J WLCA2-LD-M1J-N WLSD2 WLSD2-N WLD-LD WLD18-LD-N WLH2-LD-M1GJ WLCA2-LD-M1GJ-N WL01SD2 WLSD2-N WLD2-LE WLD28-LE-N WLH2-LD-DGJ03 WLCA2-LD-DGJ-N WLSD3 WLSD3-N WLD2-LD WLD28-LD-N WLCA2-55 WLCA2-55-N WL01SD3 WLSD3-N WLD3-LE WLD38-LE-N WLCA2-55LD WLCA2-55LD-N WL01D28 58 WL WL-N WL-N/WL WL WL-N WL WL-N WL WL-N WLCA2-55LE WLCA2-55LE-N WLCA12-RP60 WLCA12-RP60-N WLSD-TH WLSD-TH-N WLCA2-139 WLCA2-139-N WLCA12-TH WLCA12-TH-N WLSD-TC WLSD-TC-N WLCA2-139LD2 WLCA2-139LD2-N WLCA12-TC WLCA12-TC-N WLSD-RP WLSD-RP-N WLCA2-139LD3 WLCA2-139LD3-N WLCA12-RP WLCA12-RP-N WLSD2-55 WLSD2-55-N WLCA2-140 WLCA2-140-N WLCA12-P1 WLCA12-P1-N WLSD2-55LD WLSD2-55LD-N WLCA2-141 WLCA2-141-N WLH12-TH WLCA12-TH-N WLSD2-139 WLSD2-139-N WLCA2-141LD2 WLCA2-141LD2-N WLH12-TC WLCA12-TC-N WLSD2-140 WLSD2-140-N WLCA2-141LD3 WLCA2-141LD3-N WLH12-RP WLCA12-RP-N WLSD2-RP60 WLSD2-RP60-N WLCA2-RP60 WLCA2-RP60-N WLH12-P1 WLCA12-P1-N WLSD2-TH WLSD2-TH-N WLCA2-RP60LD2 WLCA2-RP60LD2-N WLCA12-2TH WLCA12-2TH-N WLSD2-TC WLSD2-TC-N WLCA2-RP60LD3 WLCA2-RP60LD3-N WLCA12-2TC WLCA12-2TC-N WLSD2-RP WLSD2-RP-N WLCA2-TH WLCA2-TH-N WLCA12-2NTH WLCA12-2NTH-N WLNJ-55 WLNJ-55-N WLCA2-TC WLCA2-TC-N WLCA12-2NTC WLCA12-2NTC-N WLNJ-55LD WLNJ-55LD-N WLCA2-RP WLCA2-RP-N WLCL-55 WLCL-55-N WLNJ-139 WLNJ-139-N WLCA2-P1 WLCA2-P1-N WLCL-55LD WLCL-55LD-N WLNJ-140 WLNJ-140-N WLH2-55 WLCA2-55-N WLCL-139 WLCL-139-N WLNJ-RP60 WLNJ-RP60-N WLH2-55LD WLCA2-55LD-N WLCL-140 WLCL-140-N WLNJ-TH WLNJ-TH-N WLH2-55LE WLCA2-55LE-N WLCL-RP60 WLCL-RP60-N WLNJ-TC WLNJ-TC-N WLH2-139 WLCA2-139-N WLCL-TH WLCL-TH-N WLNJ-RP WLNJ-RP-N WLH2-140 WLCA2-140-N WLCL-TC WLCL-TC-N WLNJ-255 WLNJ-255-N WLH2-141 WLCA2-141-N WLCL-RP WLCL-RP-N WLNJ-255LD WLNJ-255LD-N WLH2-141LD3 WLCA2-141LD3-N WLCL-P1 WLCL-P1-N WLNJ-2140 WLNJ-2140-N WLH2-RP60 WLCA2-RP60-N WLHL-TH WLCL-2NTH-N WLNJ-2RP60 WLNJ-2RP60-N WLH2-RP60LD3 WLCA2-RP60LD3-N WLHL-TC WLCL-2NTC-N WLNJ-2RP WLNJ-2RP-N WLH2-TH WLCA2-TH-N WLHL-RP WLCL-2NRP-N WLCA2-LEAS WLCA2-LEAS-N WLH2-TC WLCA2-TC-N WLHL-P1 WLCL-2NP1-N WLH2-LEAS WLCA2-LEAS-N WLH2-RP WLCA2-RP-N WLGL-TH WLGL-TH-N WLCA2-LDAS WLCA2-LDAS-N WLH2-P1 WLCA2-P1-N WLCL-2TH WLCL-2TH-N WLH2-LDAS WLCA2-LDAS-N WLCA2-255 WLCA2-255-N WLCL-2TC WLCL-2TC-N WLCA2-LES WLCA2-LES-N WLCA2-255LD WLCA2-255LD-N WLCL-2RP WLCL-2RP-N WLH2-LES WLCA2-LES-N WLCA2-255LE WLCA2-255LE-N WLCL-2NTH WLCL-2NTH-N WLCA2-LDS WLCA2-LDS-N WLCA2-2139 WLCA2-2139-N WLCL-2NTC WLCL-2NTC-N WLH2-LDS WLCA2-LDS-N WLCA2-2139LD2 WLCA2-2139LD2-N WLD2-55 WLD28-55-N WLD28-LES WLD28-LES-N WLCA2-2139LD3 WLCA2-2139LD3-N WLD2-55LD WLD28-55LD-N WLD28-LDS WLD28-LDS-N WLCA2-2RP60 WLCA2-2RP60-N WLD2-55LE WLD28-55LE-N WLMCA2-LD WLMCA2-LD-N WLCA2-2RP60LD2 WLCA2-2RP60LD2-N WLD2-139 WLD28-139-N WLMCA2-LDK13A WLMCA2-LDK13A-N WLCA2-2RP60LD3 WLCA2-2RP60LD3-N WLD2-RP60 WLD28-RP60-N WLMCA2-LDK13 WLMCA2-LDK13-N WLCA2-2TH WLCA2-2TH-N WLD2-TH WLD28-TH-N WLMCA2-LDK43A WLMCA2-LDK43A-N WLCA2-2TC WLCA2-2TC-N WLD2-TC WLD28-TC-N WLMCA2-LDK43 WLMCA2-LDK43-N WLCA2-2N55 WLCA2-2N55-N WLD2-RP WLD28-RP-N WLMCA2-LD-M1J WLMCA2-LD-M1J-N WLCA2-2N55LD WLCA2-2N55LD-N WLD28-55 WLD28-55-N WLMCA2-LD-DGJ03 WLMCA2-LD-DGJ-N WLCA2-2N55LE WLCA2-2N55LE-N WLD28-55LD WLD28-55LD-N WLMH2-LD WLMCA2-LD-N WLCA2-2N139 WLCA2-2N139-N WLD28-55LE WLD28-55LE-N WLMH2-LDK13A WLMCA2-LDK13A-N WLCA2-2N140 WLCA2-2N140-N WLD28-139 WLD28-139-N WLMH2-LDK13 WLMCA2-LDK13-N WLCA2-2NTH WLCA2-2NTH-N WLD28-140 WLD28-140-N WLMH2-LDK43A WLMCA2-LDK43A-N WLCA2-2NTC WLCA2-2NTC-N WLD28-RP60 WLD28-RP60-N WLMH2-LDK43 WLMCA2-LDK43-N WLCA12-55 WLCA12-55-N WLD28-TH WLD28-TH-N WLMH2-LD-M1J WLMCA2-LD-M1J-N WLCA12-55LD WLCA12-55LD-N WLD28-RP WLD28-RP-N WLMH2-LD-DGJ03 WLMCA2-LD-DGJ-N WLCA12-55LE WLCA12-55LE-N WLSD-55 WLSD-55-N WLRCA2 WLRCA2-N WLCA12-139 WLCA12-139-N WLSD-55LD WLSD-55LD-N WLRH2 WLRCA2-N WLCA12-140 WLCA12-140-N WLSD-139 WLSD-139-N WLRCA2-2 WLRCA2-2-N WLCA12-141 WLCA12-141-N WLSD-RP60 WLSD-RP60-N WLRCA2-2N WLRCA2-2N-N 59 WL-N/WL WL 60 WL-N WLRCA2 WLRCA2-N WLRH2 WLRCA2-N WLRCA2-2 WLRCA2-2-N WLRCA2-2N WLRCA2-2N-N WLRCL WLRCA2-N WLRCA2-2 WLRCA2-2-N WLRCA2-2N WLRCA2-2N-N WLRCA32 WLRCA32-N WLRCA2-LDS WLRCA2-LDS-N WLRH2-LES WLRCA2-LES-N WLRH2-LDS WLRCA2-LDS-N WL-N/WL Model Replacement Table (Replacing WL-N High-sensitivity and Highprecision Models with WL High-sensitivity and High-precision Models) The WL-N high-sensitivity and high-precision models have been integrated into the WL Series. To use a WL-N high-sensitivity or high-precision model, find the corresponding WL high-sensitivity or high-precision model in the following model replacement table, and order the switch with the WL model number. WL-N WLG2-TH-N WLG2-N WLG2-LDS-N WLG2-LD-N WL WL-N WL WL-N WL01G2-TH-F WLGCA2-LDS-N WLGCA2-LDS WLG2-55LD-M1JB-N WLG2-TH-F WLGCA2-LDS-M1J-1-N WLGCA2-LDS-M1J-1 WLG2-55LD-M1GJ-N WLG2-TH WLGCA2-LDS-M1GJ-1-N WLGCA2-LDS-M1GJ-1 WL01G2 WLGCA2-LD-N WLG2 WL01GCA2-LD WLGCA2-LD WL01G2-LDS WLGCA2-LD-M1J-N WLGCA2-LD-M1J WLG2-LDS WLGCA2-LD-M1GJ-N WLGCA2-LD-M1GJ 0.3M WL01G2-LD WLGCA2-LDK43-N WLG2-LD WLG2-55LDK43-N WLG2-55LDK13CE WLGCA2-LDK43 WLG2-55LD-DK1EJ-N WLG2-55LD-DK1EJ03 WLGCA2-LDK13 WLGCA2-LD-DGJ-N WLGCA2-LD-DGJ03 WLG2-LD-M1JB-N WLG2-LD-M1JB 0.3M WLGCA2-55-N WLGCA2-55 WLG2-141-N 5M WLG2-LD-M1GJ-N WLG2-LD-M1GJ 0.3M WLGCA2-55LE-N WLGCA2-55LE WLG2-141-N 2M WLG12-TH-N WLGCA2-55LD-N WLG2-LD-DGJ03 WLG2-55LDK13 WLG2-55LD-DTK1EJ-N WLGCA2-LDK13-N WLG2-LD-DGJ-N WLG2-55LDK43 WL01GCA2-LDK43 WLG2-LD-M1J WL01G2-LD-DGJ03 WLG2-55LD-M1GJ 0.3M WL01G2-55LDK43 WL01G2-55LDK13 WLG2-55LDK13-N WL01G2-LD-M1J WLG2-LD-M1J-N WL WLG2-55LD-M1JB WL01GCA2-55LD WLGCA2-55LD WLG2-55LD-DGJ-N WLG2-141LD3-N 5M WLG2-55LD-DTK1EJ03 WL01G2-55LD-DGJ03 WLG2-55LD-DGJ03 WLG2-141 5M WLG2-141 2M WL01G2-141LD3 5M WLG2-141LD3 5M WL01G12-TH WLGCA2-55LD-M1J-N WLGCA2-55LD-M1J 0.3M WLG2-141LD2-N 5M WLG2-141LD2 5M WLG12-TH WLGCA2-55LD-M1JB-N WLGCA2-55LD-M1JB 0.3M WLG2-140-N 5M WLG2-140 5M WL01G12 WLGCA2-55LD-M1GJ-N WLGCA2-55LD-M1GJ 0.3M WLG2-139-N 5M WLG2-139 5M WL01GCA2-55LDK43 WLG2-139-N 3M WLG2-139 3M WLR01G2 WLGCA2-55LDK43 WLG2-139LD3-N 5M WLG2-139LD3 5M WLRG2 WL01GCA2-55LDK13 WLG12-TC-N WLG12-TC WLGCA2-55LDK13-N WLGCA2-55LDK13 WLG12-P1-N WLG12-P1 WLGCA2-55LDK13CE WLG12-LE-N WLG12-LE WLMGCA2-LD-M1J WLGCA2-55LD-DGJ-N WLGCA2-55LD-DGJ03 WLG12-LD-N WLG12-LD WLMGCA2-LDK43-N WLMGCA2-LDK43 WLGCA2-139-N 5M WLGCA2-139 5M None WLMGCA2-LDK13-N WLMGCA2-LDK13 WLGCA2-139-N 3M WLGCA2-139 3M WL-2H4100-N (FOR WLGL-N) WLMGCA2-LDK13A-N WLMGCA2-LDK13A WLGCA2-139-N 2M WLGCA2-139 2M WL-2H2100-N (FOR WLG12-N) None WLMG2-LD-N WLMG2-LD WLMG2-LD-M1J-N WLMG2-LD-M1J WLGCA2139LD3-N 5M WLGCA21395LD3 S-FLEX 5M WL-2H1100W-N (FOR WLG2-141-N) None WLMG2-LDK43-N WLMG2-LDK43 WLGCA2-139LD3-N 5M WLGCA2-139LD3 5M WLMG2-LDK13 WLGCA2-139LD2-N 5M WLGCA2-139LD2 5M WL-2H1100S-N (FOR WLG2-S-N) None WLMG2-LDK13-N WLMG2-LDK13A-N WLMG2-LDK13A WLG2-TC-N WLG2-TC None WLMG2-LD-DGJ03 WLG2-RP WL-2H1100-N (FOR WLG2-N) WLMG2-LD-DGJ-N WLG2-RP-N WLGL-TH-N WLGL-TH WLG12-N WLRG2-N WLG12 WLRG2-LDS-N WLRG2-LDS WLMGCA2-LD-N WLMGCA2-LD WLMGCA2-LD-M1J-N WLGL-TC-N WLGL-TC WLGL-P1-N WLGL-P1 WLGL-N WL01GL WLGL WLGL-LE-N WLGL-LE WLGL-LD-N WLGL-LD WL01GCA2-TH WLGCA2-TH-N WLGCA2-2TH WLGCA2-TC-N WLGCA2-TC WLGCA2-RP-N WLGCA2-RP WLGCA2-RP60-N 5M WLGCA2-RP60 WLGCA2-RP60LD3-N 5M WLGCA2-RP60LD3 WLGCA2-RP60LD2-N 5M WLGCA2-RP60LD2 WLGCA2-TH WLGCA2-N WLGCA2-LES-N WLGCA2-LE-N WL01GCA2 WLGCA2 WLGCA2-LES WL01GCA2-LE WLGCA2-LE WLGCA2-55LDK43-N WLG2-RP60-N 5M WLG2-RP60 WLG2-RP60-N 10M WLG2-RP60 10M WLG2-RP60LD3-N 5M WLG2-RP60LD3 WLG2-RP60LD2-N 5M WLG2-RP60LD2 WLG2-P1-N WLG2-P1 WLG2-LES-N WLG2-LES WLG2-LE-N WL01G2-LE WLG2-LE WLG2-LEAS-N WLG2-LEAS WLG2-LDK43-N WLG2-LDK43 WLG2-LDK13-N WL01G2-LDK13 WLG2-LDK13 WLG2-LD-DK1EJ-N WLG2-LD-DK1EJ03 WLG2-LDAS-N WLG2-LDAS WLG2-55-N WLG2-55LE-N WLG2-55LD-N WL01G2-55 WLG2-55 WLG2-55LE WL01G2-55LD WLG2-55LD WLG2-55LD-M1TJ-N WLG2-55LD-M1TJ WLG2-55LD-M1TJB-N WLG2-55LD-M1TJB 61 WL-N/WL Safety Precautions • Be sure to ground. Otherwise electric shock may result. • Do not touch charged switch terminals while the switch has carry current, Otherwise electric shock may result. • Do not disassemble the limit switch or touch inside of it under supplying power, Otherwise electric shock may result. • Do not disassemble the limit switch or touch inside of it under supplying power, otherwise there is the possibility that electrical shock occurs. • Do not touch the wire or rod type actuator in order to prevent injury. • Connect a fuse which has 1.5 to 2 times higher breaking current than the switch rated current to the switch in series in order to prevent the switch from short-circuit damage. • On the occasion when using the switch with GB ratings, use a 10A fuse that complies IEC60269, either type gG. • The durability of switch is depends on the operating condition Be sure to check the condition with actual using condition before using, and use with the number of times of operating without a performance problem. • Otherwise, there is the possibility of spoiling the normal operation. Do not drop the switch. • Do not connect a Single Limit Switch to two power supplies that are different in polarity or type. Risk of interference. • Be sure to keep the load current less than the rated value. Otherwise, there is the possibility that the switch may be damage and/or burnout. • Do not use the Switch by itself in atmospheres containing flammable or explosive gases. Arcs and heating resulting from switching may cause fire or explosion. • Be sure to prevent the foreign materials such like a scrapped cable intrusion in to the switch when wiring. Otherwise, there is the possibility of spoiling the normal operation. • Never wire to the wrong terminals. • Do not store or use the switch with following place. Where the temperature fluctuates greatly Where the humidity is very high and condensation may occur. Where the vibration is too much Where receiving direct sunshine. Where receiving salty wind. • Do not disassemble and/or modify the switch at anytime. Otherwise, there is the possibility of spoiling the normal operation. • Do not apply the force such like deformation and/or degeneration to the switch. Precautions for Correct Use Environment • Take special care to use where there is fine powder, mud and/or foreign materials stacking. And check the condition with actual using condition before using. Then use without a performance problem. • Do not keep the Switch in locations with corrosive gas, such as sulfuric gas (H2S or SO2), ammonium gas (NH3), nitric gas (HNO3), or chlorine gas (Cl2), or high temperature and humidity.Otherwise, contact failure or corrosion damage may result. • Seal material may deteriorate if a Switch is used outdoor or where subject to special cutting oils, solvents, or chemicals. Always appraise performance under actual application conditions and set suitable maintenance and replacement periods. • Install Switches where they will not be directly subject to cutting chips, dust, or dirt. The Actuator and Switch must also be protected from the accumulation of cutting chips or sludge. Not Suitable 62 Suitable • Constantly subjecting a Switch to vibration or shock can result in wear, which can lead to contact interference with contacts, operation failure, reduced durability, and other problems. Excessive vibration or shock can lead to false contact operation or damage. Install Switches in locations not subject to shock and vibration and in orientations that will not produce resonance. • The Switches have physical contacts. Using them in environments containing silicon gas will result in the formation of silicon oxide (SiO2) due to arc energy. If silicon oxide accumulates on the contacts, contact interference can occur. If silicon oil, silicon filling agents, silicon cables, or other silicon products are present near the Switch, suppress arcing with contact protective circuits (surge suppressor) or remove the source of silicon gas. Installing the Switch • To install the Switch, make a mounting panel, as shown in the following diagram, and tighten screws using the appropriate tightening torque. Front Mounting : Four, 5.2 +0.2 0 dia. holes or M5 tapped holes 58.7±0.15 Rear Mounting : Four, 6.2 +0.2 0 dia. holes 30.2 ±0.15 Using Switches for Micro Loads Contact faults may occur if a Switch for a general-load is used to switch a micro load circuit. Use switches in the ranges shown in the diagram below. However, even when using microload models within the operating range shown here, if inrush current occurs when the contact is opened or closed, it may increase contact wear and so decrease durability. Therefore, insert a contact protection circuit where necessary. For the WL-N, the P level is at the min. operating load of 5 VDC and 1 mA resistive load. Note: The P level indicates the standard malfunction level at a reliability level of 60% (λ60). (JISC5003) λ60 =0.1×10-6/operations indicates that the estimated malfunction rate is less than 1/10,000,000 operations with a reliability level of 60%. For the WL01G@, the N level is a reference value at the min. operating load of 5 VDC and 1 mA resistive load. An estimated malfunction rate of 1/2,000,000 operations at a reliability level of 60% is indicated as a reference value. Voltage (V) Precautions for Safe Use 5 mW 800 mW 0.16 mA 30 26 mA 24 Operating range for micro-load models Operating range for standard models 12 Unusable range 5 1 mA 100 mA 160 mA 0 0.1 1 10 100 1,000 Current (mA) WL-N/WL Tightening Torque • If screws are too loose they can lead to an early malfunction of the Switch, so ensure that all screws are tightened using the appropriate tightening torque. • In particular, when changing the direction of the Head, make sure that all screws are tightened again to the appropriate tightening torque. Do not allow foreign objects to fall into the Switch. In the case of prewired connector and direct connector (1) How to handle (3) (6) Built-in Switch (5) Type Torque Screw type Head mounting screw 0.78 to 0.88 N•m M3.5 screw (2) Cover mounting screw 1.18 to 1.37 N•m M4 screw (3) Allen-head bolt (for securing the roller lever) 4.90 to 5.88 N•m M5 hexagon socket head cap screw (3) Allen-head bolt (for securing the adjustable rod lever) 0.88 to 1.08 N•m M8 hexagon socket set screw (4) Terminal screw 0.59 to 0.78 N•m M3.5 screw (5) Connector 1.77 to 2.16 N•m G1/2orPg13.5orM20or 1/2-14NPT Unit mounting screw 4.90 to 5.88 N•m M5 screw Back mounting screws 4.90 to 5.88 N•m M6 screw (1) (6) Wring In the case of mounting screw Basic Switches • Use M3.5-nylon insulation covered crimp terminals (round type) for wiring. Ex.) V1.25-M3.5(RAP1.25-3.5) (J.S.T. Mfg. Co.,Ltd.) • Appropriate wire size is AWG16 (1.25 mm2). • Do not supply electric power when wiring. Otherwise electric shock may result. • Do not pull out the wires with excessive force. It may cause of coming off the wire. • Use crimp terminals for wiring. • In the case of indicator unit, to avoid interference between lump unit and crimp terminals, wire according to right wiring figure. Attach the indicator unit spring to terminal screw certainly, otherwise it's possible to be destroyed or shorted. • The ground terminal is only installed on models with ground terminals. High-sensitivity and High-precision Switches • Use 1.25-mm2 lead wires and M4-insulation covered crimp terminals for wiring. Crimp Terminal External Dimensions Wiring Method Switch Box Section L l Changing direction of the head • By removing two head screws or four head screws, mounting in any of four orientations is possible. Be sure to change the plunger for internal operations at the same time. (4) (2) No. • Holding the connector certainly when pulling connector. • Don’t pull the cable holding it. • Do not remove or replace the built-in switch. Risk of malfunctioning. Overtravel Markers • All Switches with Roller Lever Actuators except for Switches with Fork Lock Levers and Low-temperature Switches have a set position marker plate. • To allow the roller lever type actuator to travel properly, set the roller lever according to the dog or cam stroke so that the arrowhead of the lever is positioned within the overtravel markers (pages 36, 37). Connectors • Tighten the connector with the appropriate torque to prevent deformation. • Use the OMRON type SC connector series, which is prepared separately, suitable for outer diameter of cable and inner diameter of seal rubber. • Make sure to wrap the connector with the seal tape, except the connector which has O-ring, to keep the sealability. • To conform to CSA, use a CSA certified water tight treated conduit hub. • Even when the connector is assembled and set correctly, the end of the cable and the inside of the Switch may come in contact. This can lead to malfunction, leakage current, or fire, so be sure to protect the end of the cable from splashes of oil or water and corrosive gases. Microload Applications • The WL-N Basic Models contacts can be used both for standard loads and microloads, but once a contact has been used to open and close a load it can no longer be used for lower loads. Doing so will damage the contact surface and reduce contact reliability. • If an inrush current or other sudden load occurs during a switch operation, the switch will begin to degrade severely which can result in reduced durability. Use a contact protection circuit if required. Indicator Indicator-equipped switch has contacts and indicator in parallel. When contacts are open, leakage current flows through the indicator circuit and may cause load's malfunction. Leakage current may cause load malfunction (i.e., the load may remain ON). Make sure that the load operating current is higher than the leakage current. For countermeasures, refer to technical support on your OMRON website. Ground terminal F D dia. dz dia. : 4.3 D dia. : 4.5 B : 8.5 L : 21.0 F : 7.8 l : 9.0 (mm) B dz dia. NO terminal NC terminal • The ground terminal is only installed on models with ground terminals. 63 WL-N/WL Terminal Plate Basic Switches By using the Terminal Plate (sold separately), as shown in the following diagram, the Switch can be used as a single-polarity doublebreak switch. Attach the Terminal Plate so that the “COM” mark is oriented as shown on the left. Terminal Plate Model Terminal Plate Mounting Diagram (with Two Terminal Screws Removed) WL-N TERMINAL PLATE High-sensitivity/High-precision Switches By using a short circuit plate, as shown in the following diagram, the Switch can be fabricated into a single-polarity double-break switch. When ordering, specify WL Terminal Plate (product code: WL9662F). 9 2.5 +0.2 0 7.1 3R 9 ±0.2 COM 16 ±0.15 23 ±0.4 7 2R 3.5 2.1R t = 0.6 Brass plate 4.2 +0.1 0 Using a WL@-2N Switch Mounted from the Side If you replace a previous Switch with a WL@-2N-N Switch, a Mounting Plate (sold separately) is available to maintain mounting compatibility. If you use the Mounting Plate, the Switch mounting holes and actuator position will be compatible. (The position of the dog remains unchanged.) 64 58.7 Mounting Plate 23 30.2 WL@-2N Mounting Plate Replacing a Switch with the WL@-2N-N Plate mounting bolts (2) Set contents Plate (1) Model 64 WLN-P001 Switch mounting bolts (2) WL-N/WL Operation • Carefully determine the position and shape of the dog or cam so that the actuator will not abruptly snap back, thus causing shock. In order to operate the Limit Switch at a comparatively high speed, use a dog or cam that keeps the Limit Switch turned ON for a sufficient time so that the relay or valve will be sufficiently energized. • The method of operation, the shape of the cam or dog, the operating frequency, and the travel after operation have a large influence on the durability and operating accuracy of the Limit Switch. The cam or dog must be smooth in shape. Incorrect • Make sure that the actuator does not exceed the OT (overtravel) range, otherwise the Limit Switch may malfunction. When mounting the Limit Switch, be sure to adjust the Limit Switch carefully while considering the whole movement of the actuator. Operating body PT (Pretravel) Install a stopper. 70% of 100% of rated OT rated OT FP (Free position) OP (Operating position) OT (Overtravel) TTP (Total travel position) Correct Optimum setting range Distance to the optimum setting range. Snapped back Abruptly actuated Reference line Incorrect Correct • The Limit Switch may soon malfunction if the OT is excessive. Therefore, adjustments and careful consideration of the position of the Limit Switch and the expected OT of the operating body are necessary when mounting the Limit Switch. Correct Snapped back Abruptly actuated Stopper • Appropriate force must be imposed on the actuator by the cam or dog in both rotary operation and linear operation. If the dog touches the lever as shown below, the operating position will not be stable. Incorrect Correct Dog Dog • When using a pin-plunger actuator, make sure that the stroke of the actuator and the movement of the dog are located along a single straight line. Incorrect Correct Operating body Operating body • Unbalanced force must not be imposed on the actuator. Otherwise, wear and tear on the actuator may result. Incorrect Correct Dog Dog Roller Roller • With a roller actuator, the dog must touch the actuator at a right angle. The actuator or shaft may deform or break if the dog touches the actuator (roller) at an oblique angle. Incorrect Dog Others • For long term (over a year) storage, check according to Operating characteristics, Contact resistance and Dielectric strength at least. And check with using condition. • The durability of the Switch is greatly affected by operating conditions. Evaluate the Switch under actual working conditions before permanent installation and use the Switch within a number of switching operations that will not adversely affect the Switch’s performance. Correct Dog 65 WL-N/WL Using the Switches Item Changing the Installation Position of the Actuator By loosening the Allen-head bolt on the actuator lever, the position of the actuator can be set anywhere within the 360°. With Operation Indicator-equipped Switches, the actuator lever comes in contact with the top of the indicator cover, so use caution when rotating and setting the lever. When the lever only moves forwards and backwards, it will not contact the lamp cover. (This does not apply to Long-life Models.) Changing the Orientation of the Head By removing the head screws (two or four screws), mounting in any of four orientations is possible. Be sure to change the plunger for internal operations at the same time. The roller plunger can be set in either of two positions at 90°. Applicable models and Actuators Details Roller lever: (WLCA2-N, WLCA2-2-N, WLCA2-2N-N, WLG2, WLCA2-7-N, WLCA2-8-N, WLGCA2, WLMCA2-N, WLMG2, WLMGCA2) Adjustable Roller Lever: (WLCA12-N, WLCA12-2-N, WLCA12-2N-N, WLG12) Adjustable Rod Lever: (WLCL-N, WLCL-2-N, WLCL-2N-N, WLGL, WLCAL4-N, WLCAL5-N) Roller lever: (WLCA2-N, WLCA2-2-N, WLCA2-2N-N, WLG2, WLCA2-7-N, WLCA2-8-N, WLGCA2, WLMCA2-N, WLMG2, WLMGCA2) Adjustable Roller Lever: (WLCA12-N, WLCA12-2-N, WLCA12-2N-N, WLG12) Adjustable Rod Lever: (WLCL-N, WLCL-2-N, WLCL-2N-N, WLGL, WLCAL4-N, WLCAL5-N) Horizontal plunger: (WLSD@-N) Top-roller plunger: (WLD2-N) Sealed top-roller plunger: (WLD28-N) Fork lock lever: (WLCA32-4@-N) Loosen the Allen-head bolt, set the actuator's position and then tighten the bolt again. Loosen the screws. Head Note: Excludes the -RP60-series and 141-series. One-side Operation Roller lever: (WLCA2-N, WLCA2-2-N, WLCA2-2N-N, WLCA2-7-N, WLCA2-8-N, WLMCA2-N) Adjustable Roller Lever: (WLCA12-N, WLCA12-2-N, WLCA12-2N-N) Adjustable Rod Lever: (WLCL-N, WLCL-2-N, WLCL-2N-N, WLCAL4-N, WLCAL5-N) Changing the Operating Direction By removing the Head on models which can operate on one-side only, and then changing the direction of the operational plunger, one of three operating directions can be selected. The tightening torque for the screws on the Head is 0.78 to 0.88 N·m. The output of the Switch will be changed, regardless of which direction the lever is pushed. Operating Operating Operation in both directions The output of the Switch will only be changed when the lever is pushed in one direction. Not operating Operating Operating Clockwise operation Not operating Counterclockwise operation One-side Operation for High-sensitivity and High-precision Switches The output of the Switch will be changed, regardless of which direction the lever is pushed. The output of the Switch will only be changed when the lever is pushed in one direction. Operating Operating Not operating Operating Operating Not operating Roller lever: (WLGCA2, WLMGCA2) Operational plunger Operation in both directions 66 Clockwise operation Counterclockwise operation WL-N/WL Item Applicable models and Actuators Installing the Roller on the Inside By installing the roller lever in the opposite direction, the roller can be installed on the inside. (Set so that operation can be completed within a 180° level range.) Roller lever: (WLCA2-N, WLCA2-2-N, WLCA2-2N-N, WLG2, WLCA2-7-N, WLCA2-8-N, WLGCA2, WLMCA2-N, WLMG2, WLMGCA2) Fork Lock Lever: (WLCA32-4@-N) Details Loosen the Allen-head bolt. Adjustment range radius: 25 to 140 mm Adjustable Roller Lever: (WLCA12-N, WLCA12-2-N, Adjusting the Length of the Rod or Lever WLCA12-2N-N, WLG12) The length of the rod or lever can be adjustAdjustable Rod Lever: ed by loosening the Allen-head bolt. (WLCL-N, WLCL-2-N, WLCL-2N-N, WLGL, WLCAL4-N) Loosen this Allen-head bolt and adjust the length of the lever. Adjustment range radius: 25 to 89 mm Adjustable Roller Levers: Selecting the Roller Position There are four types of Switches with Fork Lock Levers for use depending on the roller position. Fork Lock Lever: (WLCA32-4@-N) Loosen this Allen-head bolt and adjust the length of the rod. Adjustable Rod Levers: WLCA32-41-N WLCA32-43-N WLCA32-42-N WLCA32-44-N An explanation of the operation of fork lock levers is provided after this table. Operation of Fork Lock Levers A Switch with a Fork Lock Lever is constructed so that the dog pushes the lever to invert the output and this inverted state is maintained even after the dog moves on. If the dog then pushes the lever from the opposite direction, the lever will return to its original position. Example NC terminal: ON NO terminal: ON NO terminal: ON 67 WL-N/WL Limit Switch Connectors Connectors (SC Series) Cabtire cables and flexible tubes with various diameters are used to connect machine tools and controllers with Limit Switches. To ensure the watertightness of the edges of the conduits, use an SC Connector that is suitable for the external diameter of cable and model of Limit Switch. Ordering Information Connector for Cabtire Cable Conduit Applicable cable Cabtire cable (generalpurpose) JIS B 0202 G½ Cabtire cable (anti-corrosive) ½-14NPT Cabtire cable Inner diameter (D) of seal rubber 7 mm 9 mm 12.5 mm 14 mm 11 mm 7 mm 9 mm 12.5 mm 14 mm 11 mm 7 mm 9 mm 12.5 mm 14 mm 11 mm External diameter of cable Min. Max. 5.5 mm 7.5 mm 7.5 mm 9.5 mm 11 mm 13 mm 12 mm 14 mm 9 mm 11 mm 5.5 mm 7.5 mm 7.5 mm 9.5 mm 11 mm 13 mm 12 mm 14 mm 9 mm 11 mm 5.5 mm 7.5 mm 7.5 mm 9.5 mm 11 mm 13 mm 12 mm 14 mm 9 mm 11 mm Model SC-1M SC-2M SC-3M SC-4M SC-5M SC-21 SC-22 SC-23 SC-24 SC-25 SC-1PT SC-2PT SC-3PT SC-4PT SC-5PT Applicable model WL-N, WL, D4A-@N, D4B-@N, ZE, ZV, ZV2, XE, XV, XV2 D4A-@N Note: Please use sealing tape with SC Connectors. SC-1M to SC-5M, however, are provided with an O-ring (NBR) and therefore sealing tape is not necessary to ensure a proper seal. Simple Connectors (Not Suitable for Locations Subject to Oil or Water) Conduit Applicable cable JIS B 0202 G½ Pg13.5 JIS B 0202 G½ Cabtire cable Inner diameter (D) of seal rubber External diameter of cable Min. Max. Model 10.6 mm 8.5 mm 10.5 mm SC-P2 9.6 mm 7.5 mm 9.5 mm SC-P3 9 mm 7.5 mm 9 mm SC-6 Applicable model WL-N, WL, D4A-@N, D4B-@N, ZE, ZV, ZV2, XE, XV, XV2 WL@-G-N WL-N, WL, D4A-@N, D4N *, D4N-@R *, D4B-@N, ZE, ZV, ZV2, XE, XV, XV2 Note: Simple connector are made of resin. If more sealing capability is required, use one of SC-1M to SC-5M, which have metal casings. Models marked with an asterisk (*) however, can only be used with resin connectors. 68 WL-N/WL Dimensions and Structure (Unit: mm) Connectors for Cabtire Cable As for models without an O-ring, please use sealing tape with SC Connectors. Metal Models without O-ring G½ SC-21 to 25 JIS B 0202 G½ 14.6 dia. *E 15 4.8 9 24 14 dia. 27.7 29.3 Ball head lock nut (brass and nickel plating) Washer (stainless steel) Sealing rubber (nitrile rubber) Connector (brass and nickel plating) *D (34) Metal Models with O-ring G½ SC-1M to 5M 14.6 dia. *E 15 JIS B 0202 G½ 5 9 29.3 27 14 dia. Ball head lock nut (zinc die-cast and zinc plating) Washer (stainless steel) *D 30 Sealing rubber (nitrile rubber) (34) Metal Models without O-ring ½-14NPT (U.S.-standard screws) SC-1PT to 5PT 14.6 dia. 14 dia. 15 5 Sealing rubber (nitrile rubber) Connector (zinc die-cast and zinc plating) 14 29.3 ½-14NPT 24 14 dia. Ball head lock nut (zinc die-cast and zinc plating) Washer (stainless steel) Sealing rubber (nitrile rubber) Connector (zinc die-cast and zinc plating) *D 27.7 (39) Note: Dimensions not shown in the above diagrams have a variation of ±0.4 mm. Simple Connectors (Not Suitable for Locations Subject to Oil or Water) Resin Models G½ SC-P2 15 22 5 18 dia. 12.6 dia. 25.4 Resin Models Pg13.5 SC-P3 15.5 5 21 Pg13.5 Hexagonal nut (polyacetal resin) 4.5 Hexagonal nut (polyacetal resin) Conduit washer (ferrous metal and zinc plating) Ring (chloroprene rubber) 18 dia. 10.6 dia. 1 Conduit washer (ferrous metal and zinc plating) 18 dia. 9.6 dia. 22.5 12 9 (30.6) 10 9 4.5 Ring (chloroprene rubber) 18 dia. 12 dia. 23.5 Resin Models G½ SC-6 JIS B 0202 1 G½ 12 5 9 Ball head lock nut (polyacetal resin) Washer (ferrous metal and zinc plating) Sealing rubber (nitrile rubber) Connector (polyacetal resin) *D 26 G½ M20 × 1.5 Note: Dimensions not shown in the above diagrams have a variation of ±0.4 mm. * Diameter of Part Marked with Asterisk Model SC-21, -1M, -1PT SC-22, -2M, -2PT SC-23, -3M, -3PT SC-24, -4M, 4PT SC-25, -5M, -5PT SC-6 Inner diameter (D) of sealed rubber 7 mm 9 mm 12.5 mm 14 mm 11 mm 9 mm Internal diameter (E) of washer 10.4 mm 13.2 mm 14.6 mm 14.6 mm 13.2 mm 10 mm Applicable cable 5.5 to 7.5-mm dia. 7.5 to 9.5-mm dia. 11 to 13-mm dia. 12 to 14-mm dia. 9 to 11-mm dia. 7.5 to 9-mm dia. 69 MEMO 70 Terms and Conditions Agreement Read and understand this catalog. Please read and understand this catalog before purchasing the products. Please consult your OMRON representative if you have any questions or comments. Warranties. (a) Exclusive Warranty. Omron’s exclusive warranty is that the Products will be free from defects in materials and workmanship for a period of twelve months from the date of sale by Omron (or such other period expressed in writing by Omron). Omron disclaims all other warranties, express or implied. (b) Limitations. OMRON MAKES NO WARRANTY OR REPRESENTATION, EXPRESS OR IMPLIED, ABOUT NON-INFRINGEMENT, MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE OF THE PRODUCTS. BUYER ACKNOWLEDGES THAT IT ALONE HAS DETERMINED THAT THE PRODUCTS WILL SUITABLY MEET THE REQUIREMENTS OF THEIR INTENDED USE. Omron further disclaims all warranties and responsibility of any type for claims or expenses based on infringement by the Products or otherwise of any intellectual property right. (c) Buyer Remedy. Omron’s sole obligation hereunder shall be, at Omron’s election, to (i) replace (in the form originally shipped with Buyer responsible for labor charges for removal or replacement thereof) the non-complying Product, (ii) repair the non-complying Product, or (iii) repay or credit Buyer an amount equal to the purchase price of the non-complying Product; provided that in no event shall Omron be responsible for warranty, repair, indemnity or any other claims or expenses regarding the Products unless Omron’s analysis confirms that the Products were properly handled, stored, installed and maintained and not subject to contamination, abuse, misuse or inappropriate modification. Return of any Products by Buyer must be approved in writing by Omron before shipment. Omron Companies shall not be liable for the suitability or unsuitability or the results from the use of Products in combination with any electrical or electronic components, circuits, system assemblies or any other materials or substances or environments. Any advice, recommendations or information given orally or in writing, are not to be construed as an amendment or addition to the above warranty. See http://www.omron.com/global/ or contact your Omron representative for published information. Limitation on Liability; Etc. OMRON COMPANIES SHALL NOT BE LIABLE FOR SPECIAL, INDIRECT, INCIDENTAL, OR CONSEQUENTIAL DAMAGES, LOSS OF PROFITS OR PRODUCTION OR COMMERCIAL LOSS IN ANY WAY CONNECTED WITH THE PRODUCTS, WHETHER SUCH CLAIM IS BASED IN CONTRACT, WARRANTY, NEGLIGENCE OR STRICT LIABILITY. Further, in no event shall liability of Omron Companies exceed the individual price of the Product on which liability is asserted. Suitability of Use. Omron Companies shall not be responsible for conformity with any standards, codes or regulations which apply to the combination of the Product in the Buyer’s application or use of the Product. At Buyer’s request, Omron will provide applicable third party certification documents identifying ratings and limitations of use which apply to the Product. This information by itself is not sufficient for a complete determination of the suitability of the Product in combination with the end product, machine, system, or other application or use. Buyer shall be solely responsible for determining appropriateness of the particular Product with respect to Buyer’s application, product or system. Buyer shall take application responsibility in all cases. NEVER USE THE PRODUCT FOR AN APPLICATION INVOLVING SERIOUS RISK TO LIFE OR PROPERTY OR IN LARGE QUANTITIES WITHOUT ENSURING THAT THE SYSTEM AS A WHOLE HAS BEEN DESIGNED TO ADDRESS THE RISKS, AND THAT THE OMRON PRODUCT(S) IS PROPERLY RATED AND INSTALLED FOR THE INTENDED USE WITHIN THE OVERALL EQUIPMENT OR SYSTEM. Programmable Products. Omron Companies shall not be responsible for the user’s programming of a programmable Product, or any consequence thereof. Performance Data. Data presented in Omron Company websites, catalogs and other materials is provided as a guide for the user in determining suitability and does not constitute a warranty. It may represent the result of Omron’s test conditions, and the user must correlate it to actual application requirements. Actual performance is subject to the Omron’s Warranty and Limitations of Liability. Change in Specifications. Product specifications and accessories may be changed at any time based on improvements and other reasons. It is our practice to change part numbers when published ratings or features are changed, or when significant construction changes are made. However, some specifications of the Product may be changed without any notice. When in doubt, special part numbers may be assigned to fix or establish key specifications for your application. Please consult with your Omron’s representative at any time to confirm actual specifications of purchased Product. Errors and Omissions. Information presented by Omron Companies has been checked and is believed to be accurate; however, no responsibility is assumed for clerical, typographical or proofreading errors or omissions. OMRON AUTOMATION AMERICAS HEADQUARTERS • Chicago, IL USA • 847.843.7900 • 800.556.6766 • www.omron247.com OMRON CANADA, INC. • HEAD OFFICE Toronto, ON, Canada • 416.286.6465 • 866.986.6766 • www.omron247.com OMRON ARGENTINA • SALES OFFICE Cono Sur • 54.11.4783.5300 OMRON ELECTRONICS DE MEXICO • HEAD OFFICE México DF • 52.55.59.01.43.00 • 01-800-226-6766 • mela@omron.com OMRON CHILE • SALES OFFICE Santiago • 56.9.9917.3920 OMRON ELECTRONICS DE MEXICO • SALES OFFICE Apodaca, N.L. • 52.81.11.56.99.20 • 01-800-226-6766 • mela@omron.com OTHER OMRON LATIN AMERICA SALES 54.11.4783.5300 OMRON ELETRÔNICA DO BRASIL LTDA • HEAD OFFICE São Paulo, SP, Brasil • 55.11.2101.6300 • www.omron.com.br OMRON EUROPE B.V. • Wegalaan 67-69, NL-2132 JD, Hoofddorp, The Netherlands. • +31 (0) 23 568 13 00 • www.industrial.omron.eu Controllers & I/O • Machine Automation Controllers (MAC) • Motion Controllers • Programmable Logic Controllers (PLC) • Temperature Controllers • Remote I/O Authorized Distributor: Robotics • Industrial Robots • Mobile Robots Operator Interfaces • Human Machine Interface (HMI) Motion & Drives • Machine Automation Controllers (MAC) • Motion Controllers • Servo Systems • Frequency Inverters Vision, Measurement & Identification • Vision Sensors & Systems • Measurement Sensors • Auto Identification Systems Sensing • Photoelectric Sensors • Fiber-Optic Sensors • Proximity Sensors • Rotary Encoders • Ultrasonic Sensors Safety • Safety Light Curtains • Safety Laser Scanners • Programmable Safety Systems • Safety Mats and Edges • Safety Door Switches • Emergency Stop Devices • Safety Switches & Operator Controls • Safety Monitoring/Force-guided Relays Control Components • Power Supplies • Timers • Counters • Programmable Relays • Digital Panel Meters • Monitoring Products Switches & Relays • Limit Switches • Pushbutton Switches • Electromechanical Relays • Solid State Relays Software • Programming & Configuration • Runtime C151-E1-01 03/17 Note: Specifications are subject to change. © 2017 Omron. All Rights Reserved. Printed on recycled paper. Printed in U.S.A.
WLCA122TSN 价格&库存

很抱歉,暂时无法提供与“WLCA122TSN”相匹配的价格&库存,您可以联系我们找货

免费人工找货
WLCA122TSN
    •  国内价格 香港价格
    • 1+1644.625211+212.02392

    库存:0