0
登录后你可以
  • 下载海量资料
  • 学习在线课程
  • 观看技术视频
  • 写文章/发帖/加入社区
创作中心
发布
  • 发文章

  • 发资料

  • 发帖

  • 提问

  • 发视频

创作活动
WLG12-TC-N

WLG12-TC-N

  • 厂商:

    OMRON(欧姆龙)

  • 封装:

    -

  • 描述:

    LIMITSWITCH

  • 数据手册
  • 价格&库存
WLG12-TC-N 数据手册
Two-circuit Limit Switch/Long-life Two-circuit Limit Switch WL-N/WLM-N Select the Best Two-circuit Switch for the Operating Environment and Application from a Wide Range of Models • A wide selection of models is available, including general-purpose, environment-resistant, and spatterprevention switches. • Standard-feature gold-clad crossbar contacts provide high reliability. • Applicable to either standard loads or microloads. • Switches with lever actuators provide 90° overtravel, one-side operation, and four-direction head mounting. • Approved standards: EN/IEC, UL, cUL, and CCC. Contact your OMRON representative for information on approved models. Be sure to read Safety Precautions on page 44 to 48 and Safety Precautions for All Limit Switches. Features Standard Switches Features Common to All Switches Many Variations in Standard Limit Switches DPDB Operation A Wide Range of Models The double-pole, double-break structure ensures circuit braking. The series includes includes many different actuators that you select to match the workpiece shape and motion, and a wide range of Switch variations, such as models with operation indicators for easier working and maintenance and models with different types of connectors. Za (NO)14 13(NO) (NC)12 11(NC) 11 13 12 14 Load Load Environment-resistant Switches Select from Six Types of Environment Resistance The series includes airtight switches, hermetic switches, heatresistant switches, low-temperature switches, corrosion-proof switches, and weather-proof switches. You can select the model based on the onsite environment. Spatter-prevention Switches Excellent Performance on Arc Welding Lines or Sites with Spattering Cutting Powder Ideal for Welding Sites These Switches use stainless steel or resin to prevent the adhesion of spatter. They can be used to reduce problems caused by zinc power generated during welding. Long-life Switches Mechanical Endurance of 30 Million Operations Long-life Models for High-frequency Applications A mechanical durability of 30 million operations minimum is provided. The head features a double-seal structure with a head cap and oil seal. Degree of Protection; IP67 Approved Standards to Aid Export Machines The Switches are certified for EN/IEC, UL, cUL, and CCC making them ideal for export machines. Applicable to Either Standard Loads or Microloads Standard-feature gold-clad contacts provide high reliability. The use of a high-contact-pressure crossbar structure also increases reliability. Easy to Work With Downsizing of the built-in switch has increased the space to house the wiring. The insulating paper that was often in the way when wiring has been eliminated. Nickle-plated steel screws are used for the terminal screws. The screws adhere to magnetized screwdrivers to prevent dropping and loosing them. Models with Connectors to Reduce Wiring A neon lamp or LED indicates the operating status. The 3D structure of the lamp cover disperses light so you can check the operating status from the side. 1 WL-N/WLM-N Product Configuration • Basic Switches WLC@-N • High-sensitivity Switches WLG@-N • High-precision Switches WLGCA2-N • Protective Switches WLCA32-@-N • Indicator-equipped Switches: Neon lamps WL@-LE-N • Indicator-equipped Switches: Light emitting diodes (LED) WL@-LD-N • Direct-wired Switches WL-@LDK@-N • Pre-wired Switches WL@-@LD-M1@-N WL@-@LD-AGJ-N WL@-@LD-DGJ-N WL@-@LD-DK1EJ-N • Airtight Switches WL@-55-N • Hermetic Switches WL@-139-N WL@-140-N WL@-141-N WL@-145-N WL@-RP40-N WL@-RP60-N • Heat-resistant Switches WL@-TH-N • Low-temperature Switches WL@-TC-N • Corrosion-proof Switches WL@-RP-N • Weather-proof Switches WL@-P1-N • Basic Switches WLC@-@S-N • High-sensitivity Switches WLG@-@S-N • High-precision Switches WLGCA2-@S-N • Basic Switches WLMCA2-@-N • High-sensitivity Switches WLMG2-@-N • High-precision Switches WLMGCA2-@-N Standard General-purpose Operation indicators Sensor I/O connectors Environment-resistant Spatter-prevention Long-life 2 WL-N/WLM-N Environment-resistant Switches Item Type Airtight seal Model Environment-resistant Application Environment-resistant construction Uses an airtight built-in switch. WL@-55-N Note: Use the SC Connector for the conduit opening. WL@-139-N For use in locations subWL@-140-N ject to cutting oil or water. WL@-141-N Hermetic seal (Molded terminals/ WL@-145-N Anti-coolant) WL@-RP40-N Applicable models All models except the lowtemperature and heat-resistant models Note: Models can be produced using standard actuators. All models except the lowtemperature and heat-resistant models Refer to page 29 for information on the environment-resistant construction of Switches with Hermetic Seals. WL@-RP60-N Note: Models can be produced using standard actuators. Only the WLCA2-N, WLGCA2-N, or WLG2-N can be produced for the WL@141-N and WL@-145-N. Low-temperature Can be used at a temperature of –40°C (operating WL@-TC-N temperature range: –40 to 40°C), but cannot withstand icing. Heat-resistant Can be used in temperatures of 120°C (operating WL@-TH-N temperature range: 5 to 120°C). • Fluorine rubber is used for rubber parts such as the O-ring, gasket, etc. All models except airtight seal, hermetic seal, heatresistant, corrosion-proof, and indicator-equipped, nylon roller (WLCA2-26N-N), seal roller models, and resin rod (WLNJ-2-N) models For use in locations subWL@-RP-N ject to corrosive gases and chemicals. • Diecast parts, such as the switch box, are made of corrosion-proof aluminum. • Rubber sealing parts are made of fluorine rubber, which aids in resisting oils and chemicals. • Exposed nuts and screws (except the actuator section) are made of stainless steel. • Moving and rotary parts such as rollers are made of sintered stainless steel or stainless steel. • The head, box, and cover are yellow. All models except fork lever lock (WLCA32-41 to -44N), low-temperature, heatresistant, and indicatorequipped models For use in parking lots and other outdoor locations. • Rubber parts are made from epichlorhydrin rubber, which has a high-tolerance to changes in temperature. • Rollers are made of stainless steel to improve corrosion resistance. • Exposed nuts and screws are made of stainless steel. Only basic (WLCA2-N/ CA12-N/CL-N), and highsensitivity overtravel (WLG2-N/G12-N/GL-N) models (excluding heat-resistant models). This does not apply to lowtemperature or heat-resistant, or indicatorequipped switches. Corrosion-proof Weather-proof WL@-P1-N • Uses a general-purpose built-in switch. • Epichlorhydrin rubber is used for rubber parts such as the O-ring, gasket, etc. All models except airtight seal, hermetic seal, heatresistant, corrosion-proof, and indicator-equipped models 3 WL-N/WLM-N Selection Guide With the WL-N Series, OMRON will combine the switch, actuator, and wiring method required to build the ideal switch for your application. The WL-N Series consists of four basic types: general-purpose, environment-resistant, spatter-protection, and long-life switches. WLCA2-N Switches can be used for the most common applications. According to Operating Environment Ambient operating temperature Environment −10°C +80°C Models WL@-N Normal WLM@-N Water-resistant to IP67. High-temperature WL@-TH-N Heat-resistant Switches *1 WL@-TC-N Low-temperature Switches *1 To increase heat resistance, the rubber material (fluorine rubber) and the plunger material (PEEK) have been changed. −40°C +40°C Low-temperature To increase resistance to cold, epichlorhydrin rubber and other measures are used. Chemicals and oil Water drops and mist Constant water drops and mist Rubber parts are made from epichlorhydrin rubber, which has a high-tolerance to changes in temperature. WL@-P1-N Stainless steel is used for the screws. Rollers are made of stainless steel to provide superior corrosion resistance. Corrosion-proof specifications have been used for the housing, fluorine rubber has been used for rubber parts, and stainless WL@-RP-N steel has been used for screws and nuts (except for the actuator) to increase resistance to oils, chemicals, and weather. Weather-proof Switches *1 Corrosion-proof Switches *1 Uses an airtight built-in switch. WL@-55-N Cables are attached. Uses a general-purpose built-in switch. The cover screws, case cover, and conduit opening are molded from epoxy resin to increase the seal. (The cover cannot be removed.) WL@-139-N Hermetic, Molded-terminal Switches *1, *2 Cables are attached. Uses an airtight built-in switch. The case cover and conduit opening are molded from epoxy resin to increase the seal. (The cover cannot be removed.) The SC connector can be removed, so it is possible to use flexible conduit for the cable. Cables are attached. Uses an airtight built-in switch. The cover screws, case cover, and conduit opening are molded from epoxy resin to increase the seal. (The cover cannot be removed.) Airtight Switches *1 WL@-RP40-N Hermetic, Molded-terminal Switches *1, *2 WL@-140-N Hermetic, Molded-terminal Switches *1, *2 Constant water drops or splattering cutting powder Cables are attached. Uses an airtight built-in switch. The cover screws, case cover, and conduit opening are molded from epoxy resin to increase the seal. (The cover cannot be removed.) Double seal against oil including head cap countermeasure for cutting chips and an oil seal. -141: The Head section is molded from epoxy resin; Head direction cannot be changed. -145: The Head section is molded from epoxy resin; Head can be in any of 4 directions. Coolant Cables are attached. Uses an airtight built-in switch. The cover screws, case cover, conduit opening, and head screws WL@-RP60-N are molded from epoxy resin to increase the seal. Hermetic, Molded-terminal (The cover and head cannot be removed.) Switches *1, *2 Rubber parts are made from fluorine rubber to increase resistance to coolant. Spattering from welding To prevent spatter during welding, a heat-resistant resin is used for the indicator cover and screws and rollers are all made from stainless steel. WL@-141-N, -145-N Hermetic, Molded-terminal Switches *1, *2 (Only the WLCA2-N, WLG2-N, and WLGCA2-N, can be produced.) WL@-S-N *1. Not all functions can be combined with environment-resistant switches. Refer to the applicable models on the previous page. *2. Refer to page 29 for information on the construction of Hermetic Switches. 4 General-purpose Switches Long-life Switches +120°C +5°C Outdoors Operating environment Key specifications Spatter-prevention Switches WL-N/WLM-N According to Application Conditions Conditions Durability Load Switching standard loads Key specifications 10 A at 125, 250, or 500 VAC 0.8 A at 125 VDC 0.4 A at 250 VDC Models Entire WL@-@-N Series Applicable to either standard loads or microloads. Switching microloads 0.1 A at 125 VAC, resistive load 0.1 A at 30 VDC, resistive load Normal durability Mechanical: 15 million operation min. (10 million operation min. for high-sensitivity models or flexible rod models) WL@-N WL@-S-N General-purpose Switches Spatter-prevention Switches Long-life Mechanical: 30 million operation min. WLM@-N Long-life Switches According to Ease of Installation and Maintenance Operation indicator Conditions Daily inspections and maintenance checks Wiring specification Screw tightening and installation Key specifications Neon lamp 125 to 250 VAC Switching light-ON between operating/not operating. (Switching is not possible for Switches with Molded Terminals.) WL@-LE-N General-purpose, Indicator-equipped (Neon Lamp) Switches WL@-LES-N Spatter-prevention, Indicator-equipped (Neon Lamp) Switches LED 10 to 115 VAC/DC Switching light-ON between operating/not operating. (Switching not possible for models with molded terminals.) WL@-LD-N General-purpose, Indicator-equipped (LED) Switches WL@-LDS-N Spatter-prevention, Indicator-equipped (LED) Switches Screw terminals. No ground terminal. Conduit size: G1/2 WL@-N WLM@-N General-purpose Switches Long-life Switches Screw terminals. Ground terminal. Conduit size: 4 sizes WL@-N General-purpose Switches Direct-wired connector, 2-conductor. Greatly reduces wiring work. WL@-@LDK13@-N General-purpose, Direct-wired Connector Switches WLM@-LDK13@-N Long-life, Direct-wired Connector Switches Direct-wired connector, 4-conductor. Greatly reduces wiring work. WL@-@LDK43@-N General-purpose, Direct-wired Connector Switches WLM@-LDK43@-N Long-life, Direct-wired Connector Switches Pre-wired connector, 2-conductor. Greatly reduces wiring work. Smartclick connectors for even easier maintenance. WL@-@LD-M1@J-N General-purpose, Pre-wired Connector Switches WL@-@S-M1@J-1-N Spatter-prevention, Pre-wired Connector Switches WLM@-LD-M1@J-N Long-life, Pre-wired Connector Switches Pre-wired connector, 4-conductor. Greatly reduces wiring work. Smartclick connectors for even easier maintenance. WL@-@LD-@GJ-N General-purpose, Pre-wired Connector Switches WL@-@S-@GJS-N Spatter-prevention, Pre-wired Connector Switches WLM@-LD-@GJ-N Long-life, Pre-wired Connector Switches One-touch connector attachment Connector attachment in control and relay boxes Models 5 WL-N/WLM-N According to Form of Operation Detection object General Key specifications TT (total travel) PT (pretravel) 15° Operation angles 90° Models 25° 20° 90° Passing dogs WLCA2-N WLCA2-2-N WLCA2-2N-N 10° Passing dogs, high sensitivity 90° 90° 90° 90° 5° High precision R38 Dogs and workpieces (Mounts in any of 4 directions) R50 R63 WLCA2-N WLCA2-2-N WLCA2-2N-N WLCA2-@S-N WLMCA2-N General-purpose Switches General-purpose Switches General-purpose Switches Spatter-prevention Switches Long-life Switches WLG2-N WLG2-@S-N WLMG2-N General-purpose Switches Spatter-prevention Switches Long-life Switches WLGCA2-N General-purpose Switches WLGCA2-@S-N Spatter-prevention Switches WLMGCA2-N Long-life Switches ● Short lever WL@2-N One-Horizontal operation possible. WL@2-@S-N ● Head mounts in any of 4 directions. WLM@2-N Roller Lever Actuators Roller Lever Actuators Roller Lever Actuators ● Medium lever One-side operation possible. WL@2-7-N ● Head mounts in any of 4 directions. Roller Lever Actuators Long lever WL@2-8-N One-side operation possible. ● Head mounts in any of 4 directions. Roller Lever Actuators ● ● ● ● R25 to 89 Adjustable between dog and lever One-Horizontal operation possible. WL@12-N Head mounts in any of 4 directions. Adjustable Roller Lever Actuators One-Horizontal operation possible. WLCL-N Head mounts in any of 4 directions. Adjustable Rod Lever Actuators One-side operation possible. WLCAL4-N Head mounts in any of 4 directions. Adjustable Rod Lever Actuator ● One-side operation possible. WLCAL5-N Head mounts in any of 4 directions. Rod Spring Lever Actuator ● Head mounts in any of 4 directions. WLCA32-41-N Fork Lever Lock Actuator ● Head mounts in any of 4 directions. WLCA32-42-N Fork Lever Lock Actuator ● Head mounts in any of 4 directions. WLCA32-43-N Fork Lever Lock Actuator ● Head mounts in any of 4 directions. WLCA32-44-N Fork Lever Lock Actuator ● Equipped with sealing boot. Sealed Top Plunger Actuator ● Head mounts in any of 4 directions. WLSD-N Horizontal Plunger Actuator ● Equipped with sealing boot. Sealed Top-ball Plunger Actuator ● Head mounts in any of 4 directions. WLSD3-N ● Equipped with sealing boot. ● Head mounts in any of 4 directions. WLSD2-N ● ● 25 to 140 ● ● Dogs or workpieces with large deflection 350 to 380 ● Actuators 427.5 Round-trip operation of passing dogs Cams or workpieces with vertical movement 6 ● ● WLD18-N WLD38-N WLD28-N Horizontal-ball Plunger Actuator Sealed Top-roller Plunger Actuator Horizontal-roller Plunger Actuator WL-N/WLM-N Application Examples Detection of Passing Pallets on Production Lines Detection of Work Table Origins (X, Y, and Z) on Machine Tools Detection of Forward and Reverse Movement of Hydraulic Cylinders on Molding Machines Detection of Arm Movement on Welding Robots Detection of Car Pallet Positions in Parking Towers Detection of Vertical Limits on Conveyor Systems 7 WL-N/WLM-N Model Number Structure Model Number Legend (Not all combinations are possible. Contact your OMRON representative for details.) General-purpose Switches WL@ - @ @ @ @ -N (1) (2) (3) (4) (5) (1) Actuator and Property Specifications Code (2) Built-in Switch Type Pretravel (PT) Code CA2 Roller lever: R38 mm Blank CA2-7 Roller lever: R50 mm 55 CA2-8 Roller lever: R63 mm CA12 Adjustable roller lever: R25 to 89 mm CL Adjustable rod lever: 25 to 140 mm CAL4 Adjustable rod lever: 350 to 380 mm CAL5 Rod spring lever CA2-2 Roller lever: R38 mm CA12-2 Adjustable roller lever: R25 to 89 mm CL-2 15±5° CA2-2N Roller lever: R38 mm Adjustable roller lever: R25 to 89 mm Airtight built-in switch (3) Conduit Size, Ground Terminal Specifications Specifications 25±5° Blank G1/2 G1 G1/2 G Pg13.5 Y M20 TS MAX 20° Conduit Size Ground terminal None Provided * 1/2-14NPT * Models with ground terminals are certified for EN/IEC (CE Marking). Adjustable rod lever: 25 to 140 mm G2 Roller lever, high sensitivity: R38 mm G12 Adjustable roller lever, high sensitivity: R25 to 89 mm GL Adjustable rod lever, high sensitivity: 25 to 140 mm GCA2 Roller lever, high precision: R38 mm CA32-41 Fork lever lock CA32-42 Fork lever lock CA32-43 (4) Indicator Type 10° +2° −1° 5° +2°0° 50±5° Code Blank LE Neon lamp: 125 to 250 VAC LED (10 to 115 VAC/DC) (5) Lever Type Fork lever lock Code Sealed top plunger Blank D28 Sealed top-roller plunger D38 Sealed top-ball plunger SD Horizontal plunger SD2 Horizontal-roller plunger SD3 Horizontal-ball plunger NJ Flexible rod: Coil spring Flexible rod: Coil spring, multi-wire NJ-2 Flexible rod: Resin rod NJ-S2 Flexible rod: Steel wire 1.7 mm 2.8 mm 20±10 mm 40±20 mm Specifications No indicator LD D18 NJ-30 Specification Standard built-in switch Code Adjustable rod lever: 25 to 140 mm CA12-2N CL-2N 8 Lever A Specifications Standard lever (Allen-head bolt) Double nut lever WL-N/WLM-N Model Number Legend (Not all combinations are possible. Contact your OMRON representative for details.) General-purpose Switches Sensor I/O Connector Switches WL@ - @ L D @ -N (1) (2) (3) (4) (1) Actuator and Property Specifications Code CA2 Lever (2) Built-in Switch Type Pretravel (PT) Code Roller lever: R38 mm 15±5° Blank G2 Roller lever, high sensitivity: R38 mm 10° +2° −1° 55 GCA2 Roller lever, high precision: R38 mm 5° +2°0° Sealed top-roller plunger 1.7 mm D28 Specification Standard built-in switch Airtight built-in switch (3) Indicator Type Code LD Specifications LED (10 to 115 VAC/DC) (4) Connector Type Code Specification Shape K13A K13 K43A Voltage used *1 AC Direct-wired connector Threaded (M12) Wiring locations NO only Connector pin No. *2 NO: 3 4 DC NO only NO: 3 4 AC NC+NO NC: 1 2 , NO: 3 4 NC: 1 2 , NO: 3 4 K43 DC NC+NO -M1J DC NO only NO: 3 4 -M1GJ DC NO only NO: 1 4 DC NC only NC: 2 3 AC NC+NO NC: 1 2 , NO: 3 4 DC NC+NO NC: 1 2 , NO: 3 4 DC NO only NC: 2 , NO: 3 4 DC NO only NO: 3 4 DC NO only NO: 1 4 DC NC only NC: 2 3 -DTGJ DC NC+NO NC: 1 2 , NO: 3 4 -DTK1EJ DC NO only NC: 2 , NO: 3 4 -M1JB Threaded (M12) -AGJ -DGJ -DK1EJ Pre-wired connector *3 -M1TJ -M1TGJ -M1TJB Smartclick *1. DC models are certified for EN/IEC (CE Marking). *2. Refer to Contact Forms on page 16 for details on connector pin numbers. *3. The standard cable length is 0.3 m. Contact your OMRON representative for information on other cable lengths. 9 WL-N/WLM-N Model Number Legend (Not all combinations are possible. Contact your OMRON representative for details.) Environment-resistant Switches WL@ - @ @ @ @ @ @ @ @ -N (1) (2) (3) (4) (5) (6) (7) (8) (9) (1) Actuator and Property Specifications Code Lever CA2 Roller lever: R38 mm CA2-7 Roller lever: R50 mm CA2-8 Roller lever: R63 mm CA12 Adjustable roller lever: R25 to 89 mm CL Adjustable rod lever: 350 to 380 mm Rod spring lever CA2-2 Roller lever: R38 mm CA12-2 Adjustable roller lever: R25 to 89 mm 25±5° Roller lever: R38 mm CA12-2N Adjustable roller lever: R25 to 89 mm Roller lever, high sensitivity: R38 mm G12 Adjustable roller lever, high sensitivity: R25 to 89 mm GL Adjustable rod lever, high sensitivity: 25 to 140 mm Roller lever, high precision: R38 mm CA32-41 Fork lever lock CA32-42 Fork lever lock CA32-43 Fork lever lock Sealed top plunger D28 Sealed top-roller plunger D38 Sealed top-ball plunger SD Horizontal plunger Horizontal-roller plunger SD3 Horizontal-ball plunger NJ Flexible rod: Coil spring NJ-30 Flexible rod: Coil spring, multi-wire NJ-2 Flexible rod: Resin rod NJ-S2 Flexible rod: Steel wire Code 5° 2.8 mm 20±10 mm 40±20 mm Specifications Blank RP60 Airtight built-in switch. Cables are attached. Molded conduit opening, cover, cover screws, and head screws. (The cover cannot be removed and the head direction cannot be changed.) Fluorine rubber is used for all rubber parts. Conduit Size Blank G1/2 G1 G1/2 G Pg13.5 Y M20 TS Ground terminal None Provided *2 1/2-14NPT *2. Models with ground terminals are certified for EN/IEC (CE Marking). (7) Indicator Type Blank Weather-proof Specifications Specifications No indicator LE Neon lamp: 125 to 250 VAC LD LED (10 to 115 VAC/DC) *3. Cannot be combined with Corrosion-proof (RP), Weather-proof (P1), Heat-resistant (TC), or Low-temperature (TC) Switches. Standard built-in switch (8) Indicator Wiring Specification Airtight built-in switch Specifications Standard: −10°C to +80°C TH Heat-resistant: +5°C to +120°C *1 TC Low-temperature: −40°C to +40°C *1 *1. Cannot be combined with Corrosion-proof (RP) or Weather-proof (P1) Switches. Code Specifications 2 NC connection: Light-ON when operating 3 NO connection: Light-ON when not operating *4. Always include the indicator wiring specification if you specify a (5) hermetic structure and an (7) indicator. (9) Lever Type Code Blank A 10 Specifications Code Code Corrosion-proof (4) Temperature Specifications Code RP40 Airtight built-in switch. Cable is attached. Molded conduit opening and cover. (The cover cannot be removed.) SC Connector can be removed, so it is possible to use flexible conduits for the cable. Standard Code 55 145 Airtight built-in switch. Cable is attached. Molded conduit opening, cover, and cover screws. (The cover cannot be removed. The head can be mounted in any of 4 directions.) Double seal against oil including head cap countermeasure for cutting chips and an oil seal. 1.7 mm (3) Built-in Switch Type Blank 141 Airtight built-in switch. Cable is attached. Molded conduit opening, cover, head, cover screws, and head screws. (The cover cannot be removed and the head direction cannot be changed.) Double seal against oil including head cap countermeasure for cutting chips and an oil seal. +2° 0° (2) Environment-resistant Model Specifications P1 Airtight built-in switch. Cable is attached. Molded conduit opening, cover, and cover screws. (The cover cannot be removed.) (6) Conduit Size, Ground Terminal Specifications SD2 RP 140 10° +2° −1° 55° D18 Blank Standard built-in switch. Cable is attached. Molded conduit opening and cover. (The cover cannot be removed.) MAX 20° Adjustable rod lever: 25 to 140 mm G2 Specifications No cable molding. 139 Adjustable rod lever: 25 to 140 mm CA2-2N GCA2 Code 15±5° Adjustable rod lever: 25 to 140 mm CAL5 CL-2N Pretravel (PT) Blank CAL4 CL-2 (5) Hermetic Specification Specifications Standard lever (Allen-head bolt) Double nut lever WL-N/WLM-N Model Number Legend (Not all combinations are possible. Contact your OMRON representative for details.) Spatter-prevention Switches WL@ - @ @ S@ -N (1) (2) (3) (4) (1) Actuator and Property Specifications Code CA2 Lever Pretravel (PT) Roller lever: R38 mm 15±5° G2 Roller lever, high sensitivity: R38 mm 10° +2° −1° GCA2 Roller lever, high precision: R38 mm 5° +2°0° Sealed top-roller plunger 1.7 mm D28 (2) Built-in Switch Type Code Blank 55 Specifications Standard built-in switch Airtight built-in switch (3) Indicator Type Code Specifications LE Neon lamp: 125 to 250 VAC *1 LD LED (10 to 115 VAC/DC) *1. Cannot be combined with a Switch with a Connector. (4) Connector Type Specifications Code Blank Shape No connector ---DC -M1J-1 -M1GJ-1 -DGJS -DTGJS Pre-wired Connector *4 Threaded (M12) Smartclick Voltage *2 Wiring locations ---- ---NO only Connector pin No. *3 ---NO: 3 4 DC NO only NO: 1 4 DC NC+NO NC: 1 2 , NO: 3 4 DC NC+NO NC: 1 2 , NO: 3 4 *2. DC models are certified for EN/IEC (CE Marking). *3. Refer to Contact Forms on page 16 for details on connector pin numbers. *4. The standard cable length is 0.3 m. Contact your OMRON representative for information on other cable lengths. 11 WL-N/WLM-N Model Number Legend (Not all combinations are possible. Contact your OMRON representative for details.) Long-life Switches WLM@ - LD @ -N (1) (2) (3) (1) Actuator and Property Specifications Code CA2 Lever Pretravel (PT) Roller lever: R38 mm 15±5° G2 Roller lever, high sensitivity: R38 mm 10° +2° −1° GCA2 Roller lever, high precision: R38 mm 5° +2°0° (2) Indicator Type Code LD Specifications LED (10 to 115 VAC/DC) (3) Connector Type Specifications Code Blank Shape Screw terminals: G1/2 conduit ---- K13A AC Voltage Wiring locations ---- ---NO only Connector pin No. ---NO: 3 4 DC NO only NO: 3 4 AC NC+NO NC: 1 2 , NO: 3 4 K43 DC NC+NO NC: 1 2 , NO: 3 4 -M1J DC NO only NO: 3 4 AC NC+NO NC: 1 2 , NO: 3 4 DC NC+NO NC: 1 2 , NO: 3 4 DC NO only NO: 3 4 AC NC+NO NC: 1 2 , NO: 3 4 DC NC+NO NC: 1 2 , NO: 3 4 K13 K43A Direct-wired connector Threaded (M12) -AGJ -DGJ -M1TJ -ATGJ -DTGJ Threaded (M12) Pre-wired connector *1 Smartclick *1. The standard cable length is 0.3 m. Contact your OMRON representative for information on other cable lengths. 12 WL-N/WLM-N Ordering Information General-purpose Switches Standard Switches Switches with Lever Actuators Actuator Roller lever R38 Item Pretravel (PT) Model Roller lever: R50 Roller lever: R63 Model Model WLCA2-7-N WLCA2-8-N 15±5° WLCA2-N 25±5° WLCA2-2-N ----- ----- MAX20° WLCA2-2N-N ----- ----- High-sensitivity 10° +2° -1° WLG2-N ----- ----- High-precision 5° +2°0° WLGCA2-N ----- ----- Basic Actuator Adjustable roller lever Item Basic High-sensitivity Pretravel (PT) Model Adjustable rod lever: 25 to 140mm Model Adjustable rod lever: 350 to 380mm Model WLCAL4-N Rod spring lever Model 15±5° WLCA12-N WLCL-N WLCAL5-N 25±5° WLCA12-2-N WLCL-2-N ----- MAX20° WLCA12-2N-N WLCL-2N-N ----- ----- 10° +2° -1° WLG12-N WLGL-N ----- ----- ----- Actuator Fork lever lock Item Protective Movement until the lever reverses Model 50±5° Fork lever lock Model Fork lever lock Model WLCA32-41-N WLCA32-42-N WLCA32-43-N Sealed top plunger Sealed top-roller plunger Sealed top-ball plunger Fork lever lock Model WLCA32-44-N Switches with Plunger Actuators Actuator Item Basic Pretravel (PT) 1.7 mm Model WLD18-N Actuator Horizontal plunger Item Basic Pretravel (PT) 2.8 mm Model WLSD-N Model WLD28-N Horizontal-roller plunger Model WLSD2-N Model WLD38-N Horizontal-ball plunger Model WLSD3-N Switches with Flexible Rod Actuators Actuator Item Basic Pretravel (PT) 20±10 mm Actuator Item Basic Pretravel (PT) 40±20 mm Coil spring (spring diameter: 6.5) Model WLNJ-N Resin rod (rod diameter: 8) Model WLNJ-2-N Coil spring (spring diameter: 4.8) Model WLNJ-30-N Steel wire (wire diameter: 1) Model WLNJ-S2-N 13 WL-N/WLM-N General-purpose Switches Operation Indicator Switches Switches with Lever Actuators Actuator Roller lever: R38 Indicator Item Pretravel (PT) Model Model WLCA2-LE-N 25±5° WLCA2-2LE-N ----- ----- MAX20° WLCA2-2NLE-N ----- ----- High-sensitivity 10° +2° -1° WLG2-LE-N ----- ----- High-precision 5° +2°0° WLGCA2-LE-N ----- ----- 15±5° WLCA2-LD-N 25±5° WLCA2-2LD-N ----- ----- MAX20° WLCA2-2NLD-N ----- ----- High-sensitivity 10° +2° -1° WLG2-LD-N ----- ----- High-precision 5° +2°0° WLGCA2-LD-N ----- ----- Basic Basic LED Actuator Adjustable roller lever: Indicator Item Basic High-sensitivity LED Model Basic High-sensitivity Pretravel (PT) Model WLCA2-7LE-N Roller lever: R63 15±5° Neon lamp Neon lamp Roller lever: R50 WLCA2-7LD-N Adjustable rod lever: 25 to 140mm Model WLCL-LE-N WLCA2-8LE-N WLCA2-8LD-N Adjustable rod lever: 350 to 380mm Model WLCAL4-LE-N WLCA12-LE-N 25±5° WLCA12-2LE-N WLCL-2LE-N ----- ----- MAX20° WLCA12-2NLE-N WLCL-2NLE-N ----- ----- 10° +2° -1° WLG12-LE-N WLGL-LE-N ----- 15±5° WLCA12-LD-N WLCL-LD-N 25±5° WLCA12-2LD-N WLCL-2LD-N ----- ----- MAX20° WLCA12-2NLD-N WLCL-2NLD-N ----- ----- 10° +2° -1° WLG12-LD-N WLGL-LD-N ----- ----- Fork lever lock Item Movement until the lever reverses Fork lever lock Model Model WLCA32-42LE-N Neon lamp Basic 50±5° WLCA32-41LE-N LED 50±5° WLCA32-41LD-N Basic WLCAL4-LD-N ----- Fork lever lock Model WLCA32-43LE-N WLCA32-43LD-N Switches with Plunger Actuators Actuator Sealed top plunger Indicator Item Pretravel (PT) Model Sealed top-roller plunger Model Model 1.7 mm WLD18-LE-N WLD28-LE-N WLD38-LE-N LED 1.7 mm WLD18-LD-N WLD28-LD-N WLD38-LD-N Horizontal plunger Horizontal-roller plunger Actuator Indicator Item Pretravel (PT) Model Model Horizontal-ball plunger Model Neon lamp Basic 2.8 mm WLSD-LE-N WLSD2-LE-N WLSD3-LE-N LED 2.8 mm WLSD-LD-N WLSD2-LD-N WLSD3-LD-N Basic Switches with Flexible Rod Actuators Actuator Indicator Item Pretravel (PT) Coil spring (spring diameter: 6.5) Model Coil spring (spring diameter: 4.8) Model Neon lamp Basic 20±10 mm WLNJ-LE-N WLNJ-30LE-N LED 20±10 mm WLNJ-LD-N WLNJ-30LD-N Basic Actuator Indicator 14 Sealed top-ball plunger Neon lamp Basic Basic Item Pretravel (PT) Resin rod (rod diameter: 8) Model Steel wire (wire diameter: 1) Model Neon lamp Basic 40±20 mm WLNJ-2LE-N WLNJ-S2LE-N LED 40±20 mm WLNJ-2LD-N WLNJ-S2LD-N Basic Model 15±5° Actuator Indicator Rod spring lever WLCAL5-LE-N ----WLCAL5-LD-N WL-N/WLM-N General-purpose Switches Sensor I/O Connector Switches Switches with Direct-wired Connectors Actuator Roller lever: R38 Item Connector shape Built-in switch type Voltage AC General-purpose Threaded (M12) DC Airtight AC Wiring locations Connector pin No. Basic High-sensitivity High-precision Model Model Model NO only NO 3 4 WLCA2-LDK13A-N ----- ----- NC + NO NC 1 2 NO 3 4 WLCA2-LDK43A-N ----- ----- NO only NO 3 4 WLCA2-LDK13-N NC + NO NC 1 2 NO 3 4 NO only NO 3 4 NC + NO NC 1 2 NO 3 4 WLG2-LDK13-N WLGCA2-LDK13-N WLCA2-LDK43-N WLG2-LDK43-N WLGCA2-LDK43-N WLCA2-55LDK13-N WLG2-55LDK13-N WLGCA2-55LDK13-N WLCA2-55LDK43-N WLG2-55LDK43-N WLGCA2-55LDK43-N Switches with Pre-wired Connectors Actuator Roller lever R38 Item Connector shape Built-in switch type Voltage Wiring locations NO only WLCA2-LD-M1J-N Model High-precision Model WLG2-LD-M1J-N WLGCA2-LD-M1J-N WLGCA2-LD-M1GJ-N WLCA2-LD-M1GJ-N WLG2-LD-M1GJ-N NC 2 3 WLCA2-LD-M1JB-N WLG2-LD-M1JB-N NC + NO NC 1 2 NO 3 4 WLCA2-LD-DGJ-N WLG2-LD-DGJ-N NO only NO 4 3 NC 2 WLCA2-LD-DK1EJ-N WLG2-LD-DK1EJ-N ----WLGCA2-LD-DGJ-N ----- NO 3 4 WLCA2-55LD-M1J-N NO 1 4 WLCA2-55LD-M1GJ-N WLG2-55LD-M1GJ-N WLGCA2-55LD-M1GJ-N NC only NC 2 3 WLCA2-55LD-M1JB-N WLG2-55LD-M1JB-N WLGCA2-55LD-M1JB-N NC + NO NC 1 2 NO 3 4 WLCA2-55LD-DGJ-N WLG2-55LD-DGJ-N WLGCA2-55LD-DGJ-N NO only NO 4 3 NC 2 WLCA2-55LD-DK1EJ-N WLG2-55LD-DK1EJ-N ----- NO only NO 3 4 ----- WLG2-LD-M1TJ-N ----- NO only NC 2 3 ----- WLG2-LD-M1TJB-N ----- NO only Airtight General-purpose Model NO 3 4 High-sensitivity NO 1 4 Threaded (M12) Smartclick Basic NC only General-purpose DC Connector pin No. ----- WLGCA2-55LD-M1J-N Note: The standard cable length for a pre-wired connector is 0.3 m. Contact your OMRON representative for information on other cable lengths. 15 WL-N/WLM-N Contact Forms Screw Terminal Switches Screw Terminal Switches Indicator-equipped (Light-ON when Not Operating) Switches *1 Za 14 (NO) Internal circuits 13 (NO) 12 (NC) Za 14 (NO) 11 (NC) 12 (NC) 13 (NO) 11 (NC) Direct-wired Connectors/Pre-wired Connectors Indicator-equipped (Light-ON when Not Operating) Switches *1 AC DC Internal circuits Internal circuits Za NO NC 4 WL@-@K13A-N WL@-@K43A-N WL@-@-AGJ-N 4 Za NC NO 3 1 2 NO NC 3 1 2 3 4 indicate the connector pin number. NC NO WL@-@K13-N WL@-@-M1J-N WL@-@-M1TJ-N 4 3 WL@-@-M1GJ-N WL@-@-M1TGJ-N 4 1 WL@-@-M1JB-N WL@-@-M1TJB-N WL@-@K43-N WL@-@DGJ-N WL@-@DTGJ-N 4 3 2 1 2 3 1 2 3 4 indicate the connector pin number. Connector Pin Layout Diagram AC Positioning piece *2 DC Positioning piece *2 2 2 3 1 3 1 4 4 Note: Leakage current from indicator circuit may cause load malfunction (i.e., the load may remain ON). Make sure that the load operating current is higher than the leakage current. For countermeasures, refer to technical support on your OMRON website. *1. Light-ON when not operating means the indicator is lit when the actuator is free and is not light when the Switch contacts (NO) close when the actuator rotates or is pushed down. *2. The position of the positioning piece is not always the same. If using an L-shaped connector causes problems in application, use a straight connector. Connecting Sensor I/O connector cable (Socket) Type AC/DC Type Number of cable cores 2 AC 4 M12 Screw (Straight) 2 DC Cable length L (m) Model 2m XS2F-A421-DB0-F 5m XS2F-A421-GB0-F 2m XS2F-A421-D90-F 5m XS2F-A421-G90-F 2m XS2F-D421-DD0 5m XS2F-D421-GD0 2m XS2F-D421-DA0-F 5m XS2F-D421-GA0-F 2m XS2F-D421-D80-F 5m XS2F-D421-G80-F 2m XS5F-D421-D80-F 5m XS5F-D421-G80-F 4 M12 Smart click type (Straight) DC 16 4 Applicable limit switch models WL@-@K13A-N WL@-@K43A-N WL@-@-AGJ-N WL@-@K13-N WL@-@-M1J-N WL@-@-M1GJ@-N WL@-@K43-N WL@-@-M1JB-N WL@-@DGJ-N WL@-@-M1TJ-N WL@-@-M1TJB-N WL-N/WLM-N Dimensions (Unit: mm) XS2F-@421-@@0-@ XS2F-D421-@D0 L (Cable length) 40.7 6 dia. 14.9 dia. DC AC 30 5 50 Wiring Diagram Two-core model AC/DC Type Model Terminal No. XS2F-A421-DB0-F XS2F-A421-GB0-F AC 1 2 3 4 Terminal No. XS2F-D421-DD0 XS2F-D421-GD0 1 2 3 4 DC Terminal No. XS2F-D421-DA0-F XS2F-D421-GA0-F 1 2 3 4 XS5F-D421-@80-F Model Wiring Diagram Cable color of core sheath Brown Blue XS2F-A421-D90-F XS2F-A421-G90-F Cable color of core sheath Terminal No. 1 2 3 4 Blue Brown Cable color of core sheath Cable color of core sheath Brown White Blue Black XS2F-D421-D80-F XS2F-D421-G80-F Brown Blue Wiring Diagram L (Cable length) 40.7 Four-core model Wiring Diagram AC/DC Type 6 dia. Model Four-core model Wiring Diagram Terminal No. 14.9 dia. 5 30 50 DC XS5F-D421-D80-F XS5F-D421-G80-F 1 2 3 4 Cable color of core sheath Brown White Blue Black 17 WL-N/WLM-N Environment-resistant Switches Standard Switches Actuator Item Pretravel (PT) Hermetic seal Molded terminals, -141 models Model WLCA2-255-N ----- ----- MAX20° WLCA2-2N55-N ----- ----- High-sensitivity 10° +2° -1° WLG2-55-N ----- ----- High-precision 5° +2°0° WLGCA2-55-N ----- 15±5° WLCA2-139-N 25±5° WLCA2-2139-N ----- ----- MAX20° WLCA2-2N139-N ----- ----- High-sensitivity 10° +2° -1° WLG2-139-N ----- ----- High-precision 5° +2°0° WLGCA2-139-N ----- 15±5° WLCA2-140-N Basic Basic 25±5° WLCA12-55-N Model 25±5° WLCA12-139-N WLCA12-140-N ----WLCL-139-N ----WLCL-140-N ----- ----- WLCA2-2N140-N ----- ----- High-sensitivity 10° +2° -1° WLG2-140-N ----- ----- High-precision 5° +2°0° Basic ----- WLCL-55-N MAX20° ----- ----- WLCA2-141-N 25±5° ----- ----- MAX20° ----- ----- ----- ----- ----- 10° +2° -1° High-precision 5° +2°0° WLGCA2-141-N 15±5° WLCA2-RP60-N 25±5° WLCA2-2RP60-N Basic ----- 15±5° High-sensitivity Anti-coolant WLCA12-141-N WLG2-141-N MAX20° --------- ----WLCA12-RP60-N ----WLCL-RP60-N ----- ----- ----- ----- ----- ----- ----- High-sensitivity 10° +2° -1° High-precision 5° +2°0° WLGCA2-RP60-N 15±5° WLCA2-TH-N WLCA12-TH-N WLCL-TH-N 25±5° WLCA2-2TH-N WLCA12-2TH-N WLCL-2TH-N MAX20° WLCA2-2NTH-N WLCA12-2NTH-N WLCL-2NTH-N High-sensitivity 10° +2° -1° WLG2-TH-N WLG12-TH-N WLGL-TH-N High-precision 5° +2°0° WLGCA2-TH-N 15±5° WLCA2-TC-N WLCA12-TC-N WLCL-TC-N 25±5° WLCA2-2TC-N WLCA12-2TC-N WLCL-2TC-N MAX20° WLCA2-2NTC-N WLCA12-2NTC-N WLCL-2NTC-N High-sensitivity 10° +2° -1° WLG2-TC-N WLG12-TC-N WLGL-TC-N High-precision 5° +2°0° WLGCA2-TC-N 15±5° WLCA2-RP-N 25±5° ----- ----- MAX20° ----- ----- ----- ----- ----- Basic Heat-resistant Basic Low-temperature Basic Corrosion-proof Weather-proof Model Adjustable rod lever 25 to 140mm WLCA2-55-N Basic Molded terminals, -140 models Adjustable roller lever 15±5° Airtight seal Molded terminals, -139 models Roller lever R38 WLG2-RP60-N High-sensitivity 10° +2° -1° High-precision 5° +2°0° WLGCA2-RP-N 15±5° WLCA2-P1-N 25±5° ----- MAX20° ----- Basic High-sensitivity 10° +2° -1° ----- ----- ----- ----WLCA12-RP-N WLG2-RP-N WLG2-P1-N ----- ----WLCL-RP-N ----- ----WLCA12-P1-N ----WLCL-P1-N --------- WLG12-P1-N WLGL-P1-N Note: The maximum cable length for a Hermetic Switch is 5 m. Actuator Sealed top-roller plunger Model Airtight Hermetic Horizontal plunger Model Model Coil spring (spring diameter: 6.5) Model Resin rod (rod diameter: 8) Model WLD28-55-N WLSD-55-N WLSD2-55-N WLNJ-55-N WLNJ-255-N Molded terminals, -139 models WLD28-139-N WLSD-139-N WLSD2-139-N WLNJ-139-N WLNJ-2139-N Molded terminals, -140 models WLD28-140-N WLSD2-140-N WLNJ-140-N WLNJ-2140-N WLNJ-2RP60-N Anti-coolant Heat-resistant Low-temperature Corrosion-proof ----- WLD28-RP60-N WLSD-RP60-N WLSD2-RP60-N WLNJ-RP60-N WLD28-TH-N WLSD-TH-N WLSD2-TH-N WLNJ-TH-N ----- ----- WLSD-TC-N WLSD2-TC-N WLNJ-TC-N ----- WLD28-RP-N WLSD-RP-N WLSD2-RP-N WLNJ-RP-N WLNJ-2RP-N Note: The maximum cable length for a Hermetic Switch is 5 m. 18 Horizontal-roller plunger WL-N/WLM-N Environment-resistant Switches Operation indicator Switches Airtight Switches Actuator Roller lever: R38 Indicator Item Basic Neon lamp Pretravel (PT) Adjustable roller lever Model Adjustable rod lever: 25 to 140mm Model Model 15±5° WLCA2-55LE-N WLCA12-55LE-N 25±5° WLCA2-255LE-N ----- --------- MAX20° WLCA2-2N55LE-N ----- ----- High-sensitivity 10° +2° -1° WLG2-55LE-N ----- ----- High-precision 5° +2°0° WLGCA2-55LE-N ----- ----- 15±5° WLCA2-55LD-N 25±5° WLCA2-255LD-N ----- ----- MAX20° WLCA2-2N55LD-N ----- ----- Basic LED WLCA12-55LD-N WLCL-55LD-N High-sensitivity 10° +2° -1° WLG2-55LD-N ----- ----- High-precision 5° +2°0° WLGCA2-55LD-N ----- ----- Horizontal plunger Horizontal-roller plunger Sealed top-roller plunger Actuator Indicator Item Model Neon lamp Basic WLD28-55LE-N LED Basic WLD28-55LD-N Coil spring (spring diameter: 6.5) Model Model Model ----- ----- ----- WLSD-55LD-N WLSD2-55LD-N WLNJ-55LD-N Resin rod (rod diameter: 8) Model ----WLNJ-255LD-N Hermetic Switches Actuator Item Molded terminals, -139 models Molded terminals, -141 models Basic Roller lever: R38 Wiring specification NC wiring Pretravel (PT) Model NO wiring Model 15±5° WLCA2-139LD2-N WLCA2-139LD3-N 25±5° WLCA2-2139LD2-N WLCA2-2139LD3-N MAX20° ----- High-sensitivity 10° +2° -1° ----- High-precision 5° +2°0° WLGCA2-139LD2-N WLGCA2-139LD3-N 15±5° WLCA2-141LD2-N WLCA2-141LD3-N Basic 25±5° ----- MAX20° ----- High-sensitivity 10° +2° -1° High-precision 5° +2°0° Basic Anti-coolant WLG2-141LD2-N ----- ----WLG2-139LD3-N --------WLG2-141LD3-N ----- 15±5° WLCA2-RP60LD2-N WLCA2-RP60LD3-N 25±5° WLCA2-2RP60LD2-N WLCA2-2RP60LD3-N MAX20° ----- ----- High-sensitivity 10° +2° -1° WLG2-RP60LD2-N WLG2-RP60LD3-N High-precision 5° +2°0° WLGCA2-RP60LD2-N WLGCA2-RP60LD3-N Note: The maximum cable length for a Hermetic Switch is 5 m. 19 WL-N/WLM-N Spatter-prevention Switches Actuator Roller lever: R38 Sealed top-roller plunger Double Nut Lever Indicator Neon lamp LED Item Pretravel (PT) Allen-head Lever Model Model WLCA2-LES-N Model Basic 15±5° WLCA2-LEAS-N High-sensitivity 10° +2° -1° WLG2-LEAS-N High-precision 5° +2°0° Basic 15±5° WLCA2-LDAS-N WLCA2-LDS-N High-sensitivity 10° +2° -1° WLG2-LDAS-N WLG2-LDS-N ----- High-precision 5° +2°0° WLGCA2-LDS-N ----- ----- ----- WLD28-LES-N WLG2-LES-N ----- WLGCA2-LES-N ----WLD28-LDS-N Long-life Switches Item Actuator Roller lever: R38, screw terminals Roller lever, direct-wired connector High-sensitivity 10° +2° -1° High-precision 5° +2°0° Model Model Model WLMCA2-LD-N 2 conductors WLMGCA2-LD-N AC WLMCA2-LDK13A-N WLMG2-LDK13A-N WLMGCA2-LDK13A-N DC WLMCA2-LDK13-N WLMG2-LDK13-N WLMGCA2-LDK13-N WLMCA2-LDK43A-N WLMG2-LDK43A-N DC WLMCA2-LDK43-N WLMG2-LDK43-N WLMGCA2-LDK43-N 2 conductors DC WLMCA2-LD-M1J-N WLMG2-LD-M1J-N WLMGCA2-LD-M1J-N 4 conductors DC WLMCA2-LD-DGJ-N WLMG2-LD-DGJ-N *1. The default setting is light-ON when not operating (NO wiring). Turn the lamp holder by 180° to change the setting to light-ON when operating (NC wiring). (Ask your OMRON representative for information on 2-conductor models.) *2. With 0.3-m cable. 20 WLMG2-LD-N AC 4 conductors Roller lever, pre-wired connector *2 Operation indicator (LED) *1 Basic 15±5° ----- ----- WL-N/WLM-N Individual Parts Switches without Levers, Heads, and Actuators General-purpose Parts Actuator Item Pretravel (PT) Set Switch without levers Model Basic Roller lever High-sensitivity Basic Adjustable roller lever High-sensitivity Variable rod lever High-sensitivity Fork lever lock Basic Top plunger Horizontal plunger 25±5° WLCA2-2-N WLRCA2-2-N WL-3H1100-N MAX20° WLCA2-2N-N WLRCA2-2N-N WL-1H1100-N WL-1H1100-N 10° +2° -1° WLG2-N WLRG2-N WL-2H1100-N 15±5° WLCA12-N WLRCA2-N WL-1H2100-N 25±5° WLCA12-2-N WLRCA2-2-N WL-3H2100-N MAX20° WLCA12-2N-N WLRCA2-2N-N WL-1H2100-N +2° -1° WLG12-N WLRG2-N WL-2H2100-N 15±5° WLCL-N WLRCA2-N WL-1H4100-N 25±5° WLCL-2-N WLRCA2-2-N WL-3H4100-N MAX20° WLCL-2N-N WLRCA2-2N-N WL-1H4100-N 10° +2° -1° WLGL-N WLRG2-N WL-2H4100-N MAX 2.8 mm 20±10 mm Flexible rod Model WLRCA2-N MAX 1.7 mm Basic Model WLCA2-N MAX55° Basic Actuator only *2 15±5° 10° Basic Head *1 (with Actuators) Basic 40±20 mm WL-1A100 WL-2A100 WL-4A100 WLCA32-41-N WL-5H5100-N WL-5A100 WLCA32-42-N WL-5H5102-N WL-5A102 WL-5H5104-N WL-5A104 WLCA32-44-N WL-5H5104-N WL-5A104 WLD18-N WL-7H100-N ----- WL-7H400-N ----- WLCA32-43-N WLD28-N WLRCA32-N ----- WLD38-N WL-7H300-N ----- WLSD-N WL-8H100-N ----- WL-8H200-N ----- WLSD2-N ----- WLSD3-N WL-8H300-N ----- WLNJ-N WL-9H100-N ----- WL-9H200-N ----- WL-9H300-N ----- WL-9H400-N ----- WLNJ-30-N WLNJ-2-N ----- WLNJ-S2-N *1. The heads are not compatible with WL-series switches. *2. The same actuators can be used for both WL and WL-N switches. Spatter-prevention Parts Actuator Lever Type Allen-head bolt lever Item Basic High-sensitivity Roller lever Double nut lever Basic High-sensitivity Set Switch without levers Head *1 (with Actuators) Actuator only *2 Model Model Model WLCA2-LES-N WLRCA2-LES-N WLCA2-LDS-N WLRCA2-LDS-N WLG2-LDS-N WLRG2-LDS-N WLCA2-LEAS-N WLRCA2-LES-N WLCA2-LDAS-N WLRCA2-LDS-N WLG2-LDAS-N WLRG2-LDS-N WL-1H1100S-N WL-1A103S WL-2H1100S-N WL-1A105S *1. The heads are not compatible with WL-series switches. *2. The same actuators can be used for both WL and WL-N switches. Covers with Indicators (See Note.) General-purpose Parts Cover Item Spatter-prevention Parts Cover only * Model Cover Item Cover only * Model Neon lamp WL-LE-N Neon lamp WL-LES-N LED WL-LD-N LED WL-LDS-N * The covers are not compatible with WL-series switches. Note: The default setting is for light-ON when not operating. Turn the lamp holder by 180° to change the setting to light-ON when operating. 21 WL-N/WLM-N Specifications General-purpose/ Environment-resistant Switches Ratings Screw Terminals Non-inductive load (A) Rated voltage (V) Item Resistive load NC Basic or high-precision High-sensitivity Switches Note: 1. 2. 3. 4. 5. NO Inductive load (A) Lamp load NC NO Inductive load NC NO Motor load NC NO 5 3 1.5 2.5 1.5 0.8 AC 125 250 500 10 10 10 3 2 1.5 1.5 1 0.8 10 10 3 DC 8 14 30 125 250 10 10 6 0.8 0.4 6 6 4 0.2 0.1 3 3 3 0.2 0.1 10 10 6 0.8 0.4 6 6 4 0.2 0.1 AC 125 250 5 5 ---- ---- ---- DC 125 250 0.4 0.2 ---- ---- ---- The above figures are for steady-state currents. Inductive loads have a power factor of 0.4 min. (AC) and a time constant of 7 ms max. (DC). A lamp load has an inrush current of 10 times the steady-state current. A motor load has an inrush current of 6 times the steady-state current. For PC loads, use the microload models. Inrush current NC 30 A max.(15 A max. *) NO 20 A max.(10 A max. *) * For high-sensitivity switches. Minimum applicable load 5 VDC 1 mA, resistive load, P level Operation indicator Switches Model WL-LE-N WL-LD-N Item Neon lamp LED Max. rated voltage Leakage current (mA) 125 AC Approx. 0.6 250 AC Approx. 1.9 10 to 24 VAC/DC Approx. 0.4 115 VAC/DC Approx. 0.5 Characteristics Degree of protection Durability *1 IP67 Mechanical 15,000,000 operations min. *2 Electrical 750,000 operations min. *3 Operating speed Operating frequency 1 mm/s to 1 m/s (in case of WLCA2-N) Mechanical 120 operations/minute min. Electrical 30 operations/minute min. Rated frequency 50/60 Hz Insulation resistance 100 MΩ min. (at 500 VDC) Contact resistance Dielectric strength 25 mΩ max. (initial value for the built-in switch when tested alone) Between terminals of the same polarity 1,000 VAC (600 VAC), 50/60 Hz for 1 min Between currentcarrying metal part and ground 2,200 VAC (1,500 VAC), 50/60 Hz for 1 min *4 Between each terminal and non-currentcarrying metal part 2,200 VAC (1,500 VAC), 50/60 Hz for 1 min *4 Vibration resistance Malfunction 10 to 55 Hz, 1.5-mm double amplitude *5 Shock resistance Destruction 1,000 m/s2 max. Malfunction 300 m/s2 *5 Ambient operating temperature -10 to +80°C (with no icing) *6 Ambient operating humidity 35% to 95% RH Weight Approx. 255 g (in case of WLCA2-N) Note: 1. The above figures are initial values. 2. The figures in parentheses for dielectric strength are those for the high-sensitivity switches models. *1. The values are calculated at an operating temperature of +5°C to +35°C and an operating humidity of 40% to 70% RH. Contact your OMRON sales representative for more detailed information on other operating environments. *2. High-sensitivity switches and switches with flexible rod actuators: 10 million operations min. 500,000 operations min. for weather-proof models. *3. Durability is 500,000 operations min. for high-sensitivity models. 500,000 operations min. for weather-proof models. Contact your OMRON representative for information on environment-resistant switches. *4. Switches with Connectors: 1,500 V. *5. Except switches with flexible rod actuators. *6. For low-temperature models this is -40°C to +40°C (with no icing). For heat-resistant models the range is +5°C to +120°C. 22 WL-N/WLM-N Spatter-prevention Switches Ratings Screw Terminals Non-inductive load (A) Rated voltage (V) Item Resistive load NC WL@-LES-N (Without high-sensitivity overtravel models) WL@-LDS-N (Without high-sensitivity overtravel models) Note: 1. 2. 3. 4. NO Inductive load (A) Lamp load NC NO 3 2 1.5 1 Inductive load NC NO Motor load NC NO 10 10 5 3 2.5 1.5 5 AC 125 250 10 10 AC 115 10 3 1.5 10 DC 12 24 115 10 6 0.8 6 4 0.2 3 3 0.2 10 6 0.8 2.5 6 4 0.2 The above figures are for steady-state currents. Inductive loads have a power factor of 0.4 min. (AC) and a time constant of 7 ms max. (DC). A lamp load has an inrush current of 10 times the steady-state current. A motor load has an inrush current of 6 times the steady-state current. * Refer to the rating of a General-purpose / Weather-proof Switches type for the rating of a high-sensitivity overtravel type. Inrush current NC 30 A max.(15 A max. *) NO 20 A max.(10 A max. *) * For high-sensitivity switches. Minimum applicable load 5 VDC 1 mA, resistive load, P level Characteristics Degree of protection Durability *1 IP67 Mechanical Electrical Operating speed Operating frequency 15,000,000 operations min. *2 750,000 operations min. (3 A at 250 VAC, resistive load) *3 1 mm/s to 1 m/s (in case of WLCA2-LDS-N) Mechanical Electrical 120 operations/minute min. 30 operations/minute min. Rated frequency 50/60 Hz Insulation resistance 100 MΩ min. (at 500 VDC) Contact resistance Dielectric strength 25 mΩ max. (initial value for the built-in switch when tested alone) Between terminals of the same polarity 1,000 VAC (600 VAC), 50/60 Hz for 1 min Between currentcarrying metal part and ground 2,200 VAC (1,500 VAC), 50/60 Hz for 1 min *4 Between each terminal and non-currentcarrying metal part 2,200 VAC (1,500 VAC), 50/60 Hz for 1 min *4 Vibration resistance Malfunction 10 to 55 Hz, 1.5-mm double amplitude Shock resistance Destruction 1,000 m/s2 max. Malfunction 300 m/s2 Ambient operating temperature -10 to +80°C (with no icing) Ambient operating humidity 35% to 95% RH Weight Approx. 255 g (in case of WLCA2-LDS-N) Note: 1. The above figures are initial values. 2. The figures in parentheses for dielectric strength are those for the highsensitivity overtravel models. *1. The values are calculated at an operating temperature of +5°C to +35°C and an operating humidity of 40% to 70% RH. Contact your OMRON sales representative for more detailed information on other operating environments. *2. Durability is 10,000,000 operations min. for high-sensitivity models. *3. Durability is 500,000 operations min. for high-sensitivity models. 500,000 operations min. for weather-proof models. Contact your OMRON representative for information on Airtight Switches. *4. Switches with Connectors: 1,500 V. 23 WL-N/WLM-N Long-life Switches Ratings Screw Terminal Switches Direct-wired Connector and Pre-wired Connector Switches Non-inductive load (A) Rated voltage (V) Item Resistive load NC Basic or high-precision High-sensitivity Inrush current NO Lamp load Inductive load (A) Inductive load NC NO Motor load NC NO 115 AC 10 3 1.5 10 NC NO 5 2.5 12 DC 24 DC 115 DC 10 6 0.8 6 4 0.2 3 3 0.2 10 6 0.8 6 4 0.2 115 AC 5 — — — 115 DC 0.4 — — — NC 30 A max. (15 A max. *) NO 20 A max. (10 A max. *) * For high-sensitivity overtravel models. Minimum applicable load 5 VDC 1 mA, resistive load, P level Characteristics Degree of protection Durability *1 30,000,000 operations min. Electrical 30,000,000 operations min. (10 mA at 24 VDC, resistive load) 750,000 operations min. (3 A at 115 VAC, resistive load) High-sensitivity Switches: 500,000 operations min. (3 A at 115 VAC, resistive load) Operating speed Operating frequency IP67 Mechanical Mechanical Electrical 1 mm/s to 1 m/s (for WLMCA2-LD-N) 120 operations/minute 30 operations/minute Rated frequency 50/60 Hz Insulation resistance 100 MΩ min. (at 500 VDC) Contact resistance 25 mΩ max. (initial value for the built-in switch when tested alone) Between terminals of the 1,000 VAC (600 VAC), 50/60 Hz for 1 min same polarity Dielectric strength (50/ 60 Hz for 1 min) Vibration resistance Shock resistance Between current-carrying metal part and ground 2,200 VAC (1,500 VAC), 50/60 Hz for 1 min *2 Between each terminal 2,200 VAC (1,500 VAC), 50/60 Hz for 1 min and non-cur*2 rent-carrying metal part Malfunction 10 to 55 Hz, 1.5-mm double amplitude Destruction 1,000 m/s2 max. Malfunction 300 m/s2 max. Ambient operating temperature –10°C to +80°C (with no icing) Ambient operating humidity 35% to 95%RH Weight Approx. 255 g (for WLMCA2-LD-N) Note: 1. The above figures are initial values. 2. The figures in parentheses for dielectric strength are for the High-sensitivity Switches. *1. The values are calculated at an operating temperature of +5°C to +35°C, and an operating humidity of 40% to 70%RH. Contact your OMRON sales representative for more detailed information on other operating environments. *2. Switches with Connectors: 1,500 V. 24 Non-inductive load (A) Model Rated voltage (V) Resistive load NC Basic or high-precision High-sensitivity NO 115 AC 3 12 DC 24 DC 115 DC 3 3 0.8 Lamp load NC NO 3 1.5 Inductive load (A) Inductive load NC NO 3 Motor load NC NO 3 2.5 3 3 0.2 3 3 0.8 3 3 0.2 115 AC 3 — — — 115 DC 0.4 — — — Note: 1. The above figures are for steady-state currents. 2. Inductive loads have a power factor of 0.4 min. (AC) and a time constant of 7 ms max. (DC). 3. A lamp load has an inrush current of 10 times the steadystate current. 4. A motor load has an inrush current of 6 times the steadystate current. WL-N/WLM-N General-purpose/ Environment-resistant/ Spatter-prevention Switches Approved Standards Agency Standard File No. Approved models Contact your OMRON representative for information Contact your OMRON representative for information UL508 UL CSA C22.2 No.14 TÜV Rheinland EN60947-5-1 CCC (CQC) GB14048.5 Approved Standard Ratings UL/cUL (UL508, CSA C22.2 No.14) Specifications Indicator Sensor I/O connectors Approved Standards Item Basic Switches A600 1 A, 125 VDC High-sensitivity or high-precision B600 0.5 A, 125 VDC Pre-wired Connector (AC) Basic, high-sensitivity, or high-precision C300 3 A, 250 VAC Pre-wired Connector (DC) Direct-wired Connector (DC) Basic Switches 1 A, 125 VDC No Connector No indicator High-sensitivity or high-precision 0.5 A, 125 VDC Basic Switches A300 10 A, 250 VAC High-sensitivity or high-precision B300 5 A, 250 VAC Basic, high-sensitivity, or high-precision C300 3 A, 250 VAC Basic Switches A150 10 A, 115 VAC 1 A, 115 VDC High-sensitivity or high-precision B150 5 A, 115 VAC 0.5 A, 115 VDC Pre-wired Connector (AC) Basic, high-sensitivity, or high-precision C150 3 A, 115 VAC Pre-wired Connector (DC) Direct-wired Connector (DC) Basic Switches 1 A, 115 VDC High-sensitivity or high-precision 0.5 A, 115 VDC No Connector Neon lamp Pre-wired Connector (AC) No Connector LED A600 Authentication conditions Rated voltage 120 VAC 240 VAC 480 VAC 600 VAC Energizing current 10 A Current (A) Volt-ampere (VA) Make Break Make Break 60 30 15 12 6 3 1.5 1.2 7,200 720 B600 Authentication conditions Rated voltage 120 VAC 240 VAC 480 VAC 600 VAC Energizing current 5A Current (A) Volt-ampere (VA) Make Break Make Break 30 15 7.5 6 3 1.5 0.75 0.6 3,600 360 C300 Authentication conditions Rated voltage 120 VAC 240 VAC Energizing current 2.5 A Current (A) Volt-ampere (VA) Make Break Make Break 15 7.5 1.5 0.75 1,800 180 A300 Authentication conditions Rated voltage 120 VAC 240 VAC Energizing current 10 A Current (A) Make 60 30 Break 6 3 Volt-ampere (VA) Make Break 7,200 720 25 WL-N/WLM-N B300 Authentication conditions Rated voltage Energizing current 120 VAC 240 VAC 5A Current (A) Volt-ampere (VA) Make Break Make Break 30 15 3 1.5 3,600 360 A150 Authentication conditions Rated voltage Energizing current 120 VAC 10 A Current (A) Volt-ampere (VA) Make Break Make Break 60 6 7,200 720 Make Break Make Break 30 3 3,600 360 Make Break Make Break 15 1.5 1,800 180 B150 Authentication conditions Rated voltage Energizing current 120 VAC 5A Current (A) Volt-ampere (VA) C150 Authentication conditions Rated voltage Energizing current 120 VAC 2.5 A Current (A) Volt-ampere (VA) TÜV (EN 60947-5-1) (Certification Only for Switches with Ground Terminals and DC Switches with Connectors) Specification Authentication conditions With ground terminals No indicator Neon lamp With DC Connector LED Working load category AC-15 DC-12 AC-15 AC-15 DC-12 DC-12 Rated working voltage (Ue) 250 V 48 V 250 V 115 V 48 V 48 V Rated working current (Ie) 2A Conditional short-circuit current 100 A Short-circuit protective device (SCPD) 10 A, fuse type gG Rated insulation voltage (Ui) Rated impulse dielectric strength (Uimp) 250 V 48 V 4 kV 800 V Pollution degree 3 Class I Electric shock protection class Class III CCC (GB14048.5) Authentication conditions LED Neon lamp With DC Connector With AC Connector Working load category AC-15 DC-13 AC-15 AC-15 DC-13 DC-13 AC-15 Rated working voltage (Ue) 250 V 48 V 250 V 250 V 48 V 48 V 250 V Rated working current (Ie) Conditional short-circuit current Short-circuit protective device (SCPD) Rated insulation voltage (Ui) 26 Specification No indicator 2A 1000 A 10 A, fuse type gG 250 V WL-N/WLM-N Structure and Nomenclature Structure General-purpose Switches: WLCA2-N Actuator Head-mounting Screws Roller The roller is made of self-lubricating sintered stainless steel and boasts high resistance to wear. Head Lever The lever is forged from corrosion-resistant aluminum alloy. It provides superior corrosion resistance and outstanding strength. With roller lever, adjustable rod and flexible rod models, the actuator position can be set anywhere within 360°. (The lever cannot be mounted in the opposite direction.) You can remove the two screws to mount the switch in any of the four possible orientations. Shaft Section Seal An oil seal is fitted on the inlet of the shaft section to maintain a tight seal. Roller Lever Bolt Operational Plunger Set Position Marker Plate Set the indicator needle so that it is between protrusions on the bearing section on the marker plate after operation. Head Set position marker plate You can change the direction of the operational plunger to electrically switch the direction of operation between both sides, left only, or right only. Built-in Switch Built-in switch with SPST-NO+NC contact form. Requires maintenance (excessive overtravel) Proper range Requires maintenance (insufficient overtravel) Proper range Terminal Screws Four, M3.5 screws Requires maintenance (excessive overtravel) Cover Setscrew A combination Philips-slotted screw is used. A retainer prevents the screw from falling from the cover even when the screw is loose. Cover Conduit Opening *1 The conduit screw is a parallel screw for G1/2 piping, and is used together with an SC connector to maintain a tight seal. Cover Seal High sealing performance is achieved. The seal also serves as a spacer. There is no troublesome insulating paper, making it easy to work with the switch. *1. The available conduit screws are Pg 13.5, M20 and 1/2-14 NPT. 27 WL-N/WLM-N Indicators Indicator Covers Indicator The indicator covered if outsert molded from diecast aluminum and has outstanding sealing properties. The indicator is either a neon lamp or an LED. Switches with LED indicators have a built-in rectifier stack, so there is no connection polarity. Indicator Windows Operating status (i.e., light-ON when operating or light-ON when not operating) depends on whether a neon lamp or an LED is used. Contact Spring Light-ON when Operating/Not Operating Lamp Holder Indicators can be switched from light-ON when operating and light-ON when not operating, by simply rotating the indicator holder by 180°. Light-ON when Operating Use the terminal screws on the built-in switch to connect to the lamp terminals. A coil spring is used to make contact, so connecting to the lamp terminals is not necessary. Light-ON when Not Operating LED at top Light-ON when not operating LED at bottom Operation Internal Circuits Power Neon lamp Built-in switch 14 Light-ON when operating *1 Za 13 Contact spring WL-LE-N 12 11 Resistor Load Internal circuits WL-LE-N WL-LD-N Power Rectifier stack Contact spring Internal circuits Resistor Light-ON when not operating *2 Za 14 13 12 11 Built-in switch Load WL-LD-N Zener diode Rated current diode Resistor LED Note: 1. Leakage current from indicator circuit may cause load malfunction (i.e., the load may remain ON). Make sure that the load operating current is higher than the leakage current. For countermeasures, refer to technical support on your OMRON website. *1. Light-ON when operating means that the lamp lights when the limit switch contacts (NC) release, or when the actuator rotates or is pushed down. *2. Light-ON when not in operation means that the lamp remains lit when the actuator is free, or when the limit switch contacts (NO) close when the actuator rotates or is pushed down. 28 WL-N/WLM-N Environment-resistant Switches Molding Specifications for Hermetic Switches WL@-139-N : Molded parts WL@-140-N WL@-141-N Head cap Airtight built-in switch Standard built-in switch WL@-145-N Head cap Oil seal WL@-RP40-N Airtight built-in switch WL@-RP60-N Oil seal Airtight built-in switch Airtight built-in switch Airtight built-in switch * Fluorine rubber is used for all rubber parts. Model Cable specifications WL@-139-N WL@-140-N WL@-141-N WL@-145-N WL@-RP40-N WL@-RP60-N Connector type Resin cap Standard 5-m VCT cable, with high flexibility and good anti-oil properties attached. Finished outer diameter: 11.5 mm, 4 conductors. Metal connector Resin connector * Resin cap * The connector can be removed, so it is possible to use flexible conduit for the cable. 29 WL-N/WLM-N Spatter-prevention Switches: WLCA2-LES-N Actuator Roller, Roller Axis Using stainless steel prevents spatter from adhering. Operating Lever A baking finish is applied to the surface so that any adhering spatter is easily removed. Roller Lever Bolt Stainless steel construction to prevent spatter adherence. Double nut models are also available. Screws Externally visible screws on the head and cover are made of stainless steel to prevent spatter adherence. Head Cap Using fluororesin prevents spatter from adhering. * Spatter means the zinc powder produced when welding. Adhering spatter to the limit switch may cause malfunction of lever or lamp cover. The lack of gap prevents spatter powder from clogging. 30 WL-N/WLM-N Long-life Switches Head Cap Head The head cap helps prevent the entry of cutting chips.You can use the protrusion on the cap to confirm the set position. You can remove the two screws to mount the head in any of the four possible directions. Actuator Shield Structure Roller A head cap and oil seal form a double-seal structure. Excellent durability and reliability are ensured. The roller is made of self-lubricating sintered stainless steel. It provides superior resistance to wear. Lever The lever is forged from anti-corrosive aluminum alloy. It provides superior corrosion resistance and outstanding strength. With a roller lever actuator, the actuator position can be set anywhere within 360°. (The lever cannot be mounted in the opposite direction.) Oil seal Head cap Operating Plunger PEEK resin is used. It provides superior resistance to wear. You can change the mounting direction to use any one of the three operating directions (both sides, left side, or right side). Built-in Switch Built-in switch with an SPST-NO+NC contact form. Cover Seal High sealing performance is achieved. The seal also serves as a spacer. There is no troublesome insulating paper, making it easy to work with the Switch. Terminal Screws Four, M3.5 screws. Cover Setscrew Conduit Opening In addition to parallel threads for G1/2 tubing, direct-wired and pre-wired connectors have been added to the series. Cover A combination Philips-slotted screw is used. A retainer prevents the screw from falling from the cover even when the screw is loose. 31 WL-N/WLM-N Dimensions and Operating Characteristics (Unit: mm) General-purpose Switches Standard Switches Switches with Roller Lever Actuators Basic, High-sensitivity, and High-precision Switches Roller lever R38 Basic High-sensitivity WLCA2-N WLG2-N WLCA2-2-N WLCA2-2N-N 17.5×7 dia. * Roller lever R50 Basic WLCA2-7-N High-precision WLGCA2-N 60 max. 53±1.5 41.5±1.5 40±1.5 25.4 13.1 Two, M3.5 17.5×15 dia. * 12.7 12.7 Four, 5.2 dia. holes 25.4 M5 Allen-head bolt 14.7 (137) 14.7 68.7 Three, M4 21.6 (15.1) 29.2±1.2 42 max. 53.2±0.8 JIS B 0202 G½ 30.2±0.2 40±0.7 68.7 58.7±0.2 5 (4.9) 25.4 M5 Allen-head bolt Four, 5.2 dia. holes 58.7±0.2 25.4 13.1 Two, M3.5 R50 R38 (125) 67.2 max. 58.1±1.5 41.5±1.5 36±1.5 Three, M4 5 Four, M6 Depth: 15 min. 21.6 (4.9) JIS B 0202 G½ (15.1) 29.2±1.2 42 max. 53.2±0.8 30.2±0.2 40±0.7 * Stainless sintered roller Four, M6 Depth: 15 min * Stainless sintered roller The only difference in the shape for High-sensitivity and High-precision Switches is the set position marker plate. Roller lever R63 Basic WLCA2-8-N 60 max. 53±1.5 41.5±1.5 40±1.5 17.5×7 dia. * 25.4 13.1 R63 Two, M3.5 14.7 Adjustable range: 25 to 89 25.4 58.7±0.2 5 (4.9) 21.6 (15.1) 30.2±0.2 JIS B 0202 G½ 40±0.7 25.4 M5 Allen-head bolt 68.7 Three, M4 5 (4.9) 12.7 Four, 5.2 dia. holes 14.7 58.7±0.2 41.5±1.5 25.4 13.1 Two, M3.5 12.7 M5 Allen-head bolt Four, 5.2 dia. holes (150) Adjustable roller lever Basic High-sensitivity WLCA12-N WLG12-N WLCA12-2-N 67 max. 17.5×7 dia. * 60±1.5 WLCA12-2N-N 29.2±1.2 42 max. 53.2±0.8 Four, M6 Depth: 15 min 68.7 Three, M4 (15.1) 30.2±0.2 40±0.7 JIS B 0202 G½ 21.6 29.2±1.2 42 max. 65.2±0.8 Four, M6 Depth: 15 min * Stainless sintered roller * Stainless sintered roller Only the external appearance of the set position indicator plate varies on high-sensitivity models. Note: Unless otherwise indicated, a tolerance of ±0.4 mm applies to all dimensions. Model Operating characteristics Operating force Release force Pretravel Overtravel Movement Differential OF RF PT OT MD max. min. min. max. Model Operating characteristics Operating force Release force Pretravel Overtravel Movement Differential OF RF PT OT MD max. min. min. max. WLCA2-N WLCA2-2-N WLCA2-2N-N WLG2-N WLCA2-7-N WLCA2-8-N WLGCA2-N 13.34 N 1.18 N 15±5° 70° 12° 13.34 N 1.18 N 25±5° 60° 16° 13.34 N 1.18 N 20° max. 70° 10° 13.34 N 1.18 N +2° 10° −1° 80° 7° 10.2 N 0.9 N 15±5° 70° 12° 8.04 N 0.71 N 15±5° 70° 12° 13.34 N 1.18 N +2° 5° 0° 85° 3° WLCA12-N *1 WLCA12-2-N *1 WLG12-2N-N *1 WLG12-N *1 13.34 N 1.18 N 15±5° 70° 12° 13.34 N 1.18 N 25±5° 60° 16° 13.34 N 1.18 N 20° max. 70° 10° 13.34 N 1.18 N +2° 10° −1° 80° 7° *1. The operating characteristics for WLCA12-N, WLCA12-2-N, WLCA12-2N-N, and WLG12-N are measured at the lever length of 38 mm. 32 WL-N/WLM-N Switches with Roller Lever Actuators Basic, High-sensitivity, and Protective Switches Adjustable rod lever 25 to 140 mm Basic High-sensitivity WLCL-N WLGL-N WLCL-2-N 9 WLCL-2N-N Adjustable rod lever Basic WLCAL4-N 67 max. 8 3.2 dia. * 55 max. 46±1.5 3±0.2 dia. (length:160) * Adjustable range: 25 to 140 Two, M3.5 M8 Allen-head set screw 41.5±1.5 25.4 13.1 12.7 Adjustable range: 350 to 380 12.7 Four, 5.2 dia. holes 65 25.4 14.7 68.7 58.7±0.2 5 25.4 M5 Allen-head set screw Four, 5.2 dia. holes 14.7 M5 Allen-head set screw Three, M4 58.7±0.2 54.5±1.5 12.8 41.5±1.5 25.4 13.1 68.7 Three, M4 5 (4.9) (15.1) 30.2±0.2 40±0.7 JIS B 0202 G½ (4.9) 21.6 Four, M6 Depth: 15 min. 29.2±1.2 42 max. JIS B 0202 G½ (15.1) 30.2±0.2 40±0.7 21.6 29.2±1.2 42 max. Four, M6 Depth: 15 min. * Stainless steel rod * Stainless steel rod Only the external appearance of the set position indicator plate varies on high-sensitivity models. Rod spring lever Basic WLCAL5-N Fork lever lock Protective Switches WLCA32-41-N WLCA32-42-N WLCA32-43-N WLCA32-44-N 67max. 7.5 2.3 dia. * The WLCA32-41-N is shown in the following diagram. 428.5±2 54.5±1.5 Two, 17.5×7 dia. * 90°±3° 41.5±1.5 25.4 65 R38 Two, M3.5 13.1 12.7 14.7 Four, 5.2 dia. holes 11 14.7 34.1 M5 Allen-head set screw Four, 5.2 dia. holes Three, M4 (125) 25.4 M5 Allen-head bolt 62.5 max. 56.4±3.5 42.8±3.5 25.4 13.1 12.7 58.7±0.2 68.7 68.7 58.7±0.2 Three, M4 5 (15.1) 21.6 JIS B 0202 G½ (4.9) 5 (4.9) (15.1) 30.2±0.2 40±0.7 JIS B 0202 G½ 21.6 29.2±1.2 42 max. Four, M6 Depth: 15 min. 30.2±0.2 29.2±1.2 40±0.7 42 max. 4-M6 Four, M6 Depth: 15 min. * Plastic Roller (The WLCA32-041-N to WLCA32-044-N have stainless steel rollers.) * Piano wire Note: 1. Unless otherwise indicated, a tolerance of ±0.4 mm applies to all dimensions. Model Operating characteristics Operating force Release force Pretravel Overtravel Movement Differential OF RF PT OT MD max. min. min. max. WLCL-N *1 WLCL-2-N *1 WLCL-2N-N *1 WLGL-N *1 WLCAL4-N *2 WLCAL5-N 1.39 N 0.27 N 15±5° 70° 12° 1.39 N 0.27 N 25±5° 60° 16° 1.39 N 0.27 N 20° max. 70° 10° 2.84 N 0.25 N +2° 10° −1° 80° 7° 0.98 N 0.15 N 15±5° 70° 12° 0.9 N 0.09 N 15±5° 70° 12° Note: The actuator on the WLCAL4-N and WLCAL5-N is heavy, which may result in resetting problems depending on the direction the Switch is mounted. Mount the Switch so that the actuator is facing downwards to prevent this problem from occurring. *1. The operating characteristics for WLCL-N, WLCL-2-N, WLCL-2N-N, and WLGL-N are measured at the lever length of 140 mm. *2. The operating characteristics of WLCAL4-N are measured at a rod length of 380 mm. Model Operating characteristics Force necessary to reverse the direction of the lever Movement until the lever reverses Movement until switch operation Movement after switch operation max. max. min. WLCA32-41 to 44-N 11.77 N 50±5° 55° 35° 33 WL-N/WLM-N Switches with Plunger Actuators Basic Switches Sealed Top Plunger WLD18-N 10 dia. 13.1 R1 * 12.9 PT Horizontal Plunger WLSD-N 13.1 Two, M3.5 12.7 25 dia. *2 R1 Two, M3.5 OP 27.5 17.8 9.3 dia. *1 (96.2) Four, 5.2 dia. holes 58.7±0.2 Four, 5.2 dia. holes 58.7±0.2 68.7 68.7 Three, M4 Three, M4 5 (4.9) * Stainless steel plunger OP 46.6±0.8 PT 25.4 (15.1) 30.2±0.2 JIS B 0202 G½ 40±0.7 Sealed Top-roller Plunger WLD28-N PT 21.6 29.2±1.2 42 max. Four, M6 Depth: 15 min (4.9) (15.1) 30.2±0.2 JIS B 0202 G½ 40±0.7 13.1 14.3 dia.×5 * 5 *1. Stainless steel plunger *2. Cosmetic nuts 12.9 Horizontal-roller Plunger WLSD2-N 25.4 PT Two, M3.5 21.6 29.2±1.2 42 max. Four, M6 Depth: 15 min OP 55.7±0.8 13.1 12.7 25 dia. *2 Two, M3.5 OP 27.5 17.8 17 dia.×4.6 *1 (96.2) Four, 5.2 dia. holes 58.7±0.2 Four, 5.2 dia. holes 58.7±0.2 68.7 68.7 Three, M4 Three, M4 5 (4.9) *Stainless sintered roller (15.1) 30.2±0.2 JIS B 0202 G½ 40±0.7 Sealed Top-ball Plunger 15.5 dia. WLD38-N PT 1/2" dia. 21.6 29.2±1.2 42 max. 5 Four, M6 Depth: 15 min (4.9) (15.1) 30.2±0.2 JIS B 0202 G½ 40±0.7 13.1 12.9 * *1. Stainless sintered roller *2. Cosmetic nuts Horizontal-ball Plunger WLSD3-N 25.4 PT Two, M3.5 21.6 29.2±1.2 42 max. OP 46.6±0.8 25 dia. *2 Four, M6 Depth: 15 min 13.1 12.7 Two, M3.5 OP 15.5 dia. 27.5 17.8 1/2" dia. *1 (96.2) Four, 5.2 dia. holes 58.7±0.2 Four, 5.2 dia. holes 58.7±0.2 68.7 68.7 Three, M4 Three, M4 5 * Stainless steel ball (4.9) (15.1) 30.2±0.2 40±0.7 JIS B0202 G½ 21.6 29.2±1.2 42 max. Four, M6 Depth: 15 min * 1. Stainless steel ball * 2. Cosmetic nuts 5 (4.9) (15.1) 30.2±0.2 JIS B0202 G½ 40±0.7 21.6 29.2±1.2 42 max. Four, M6 Depth: 15 min Note: Unless otherwise indicated, a tolerance of ±0.4 mm applies to all dimensions. Model Operating characteristics 34 WLD18-N WLD28-N WLD38-N WLSD-N WLSD2-N WLSD3-N Operating force Release force Pretravel Overtravel Movement Differential OF RF PT OT MD max. min. max. min. max. 26.67 N 8.92 N 1.7 mm 6.4 mm 1 mm 16.67 N 4.41 N 1.7 mm 5.6 mm 1 mm 16.67 N 4.41 N 1.7 mm 5.6 mm 1 mm 40.03 N 8.89 N 2.8 mm 6.4 mm 1 mm 40.03 N 8.89 N 2.8 mm 5.6 mm 1 mm 40.03 N 8.89 N 2.8 mm 4 mm 1 mm Operating position Total travel position OP TTP max. 34±0.8 mm 29.5 mm 44±0.8 mm 39.5 mm 44.5±0.8 mm 41 mm 40.6±0.8 mm — 54.2±0.8 mm — 54.1±0.8 mm — WL-N/WLM-N Switches with Flexible Rod Actuators Basic Switches Coil Spring WLNJ-N Coil Spring (Multi-wire) WLNJ-30-N *1 PT *1 6.5 dia. PT *3 4.8 dia. *3 *2 *2 (107) (107) 140±2.5 140±2.5 13.1 12.9 13.1 12.9 Two, M3.5 Two, M3.5 33.7±0.8 33.7±0.8 Four, 5.2 dia. holes Four, 5.2 dia. holes 58.7±0.2 68.7 58.7±0.2 68.7 Three, M4 Three, M4 5 (4.9) (15.1) 30.2±0.2 JIS B 0202 G½ 40±0.7 21.6 29.2±1.2 42 max. Four, M6 Depth: 15 min (4.9) (15.1) 30.2±0.2 21.6 29.2±1.2 42 max. Four, M6 Depth: 15 min *1. Do not operate the Switch in the direction of the axial center. *2. Piano wire coil spring. *3. The range for operation is 1/3rd of the overall spring length from the end of the spring. Steel Wire WLNJ-S2-N *1 PT JIS B 0202 G½ 40±0.7 *1. Do not operate the Switch in the direction of the axial center. *2. Stainless steel coil spring. *3. The range for operation is 1/3rd of the overall spring length from the end of the spring. Resin Rod WLNJ-2-N 5 *1 *3 1 dia PT 8 dia. *3 *2 (95.4) (159) 140±2.5 13.1 12.9 26 dia. *2 193±2.5 13.1 12.9 Two, M3.5 44.6±0.8 Two, M3.5 33.7±0.8 Four, 5.2 dia. holes 58.7±0.2 Four, 5.2 dia. holes 68.7 58.7±0.2 Three, M4 5 (4.9) (15.1) 30.2±0.2 JIS B0202 G½ 40±0.7 68.7 Three, M4 21.6 29.2±1.2 42 max. Four, M6 Depth: 15 min 5 (4.9) (15.1) 30.2±0.2 JIS B 0202 G½ 40±0.7 *1. Do not operate the Switch in the direction of the axial center. *2. Polyamide Resin Rod *3. The range for operation is 1/3rd of the overall rod length from the end of the rod. 21.6 29.2±1.2 42 max. Four, M6 Depth: 15 min *1. Do not operate the Switch in the direction of the axial center. *2. Stainless steel wire. *3. The range for operation is 1/3rd of the overall wire length from the end of the wire. Note: Unless otherwise indicated, a tolerance of ±0.4 mm applies to all dimensions. Model Operating characteristics Operating force Pretravel OF PT Max. WLNJ-N WLNJ-30-N WLNJ-2-N WLNJ-S2-N 1.47 N 20±10 mm 1.47 N 20±10 mm 1.47 N 40±20 mm 0.28 N 40±20 mm * These values are for the top end of the spring, rod, or wire. 35 WL-N/WLM-N Sensor I/O connector Switches (For details about applicable cables, refer to Connecting Sensor I/O Connectors Cable and Socket on page 16.) Switches with Roller Lever Actuators Switches with Direct-wired Connectors Basic Switches WLCA2-LDK13-N High-sensitivity Switches WLG2-LDK13-N High-precision Switches WLGCA2-LDK13-N Switches with Pre-wired Connectors Basic Switches WLCA2-LD-M1J-N High-sensitivity Switches WLG2-LD-M1J-N High-precision Switches WLGCA2-LD-M1J-N 17.5×7 dia. * 60 max. 53±1.5 41.5±1.5 40±1.5 25.4 13.1 12.7 17.5×7 dia. * Two, M3.5 Two, M3.5 R38 M5 Allen-head bolt 14.7 Four, 5.2 dia. holes M5 Allen-head bolt (125) 12.7 Four, 5.2 dia. holes 25.4 R38 14.7 60 max. 53±1.5 41.5±1.5 40±1.5 25.4 13.1 (125) 25.4 58.7±0.2 68.7 Three, M4 68.7 58.7±0.2 5 Three, M4 (4.9) (15.1) 5 12.5 (4.9) (15.1) 30.2±0.2 40±0.7 29.2±1.2 42 max. 53.2±0.8 M12×1 Four, M6 Depth: 15 min SC-1M Four, M6 Depth: 15 min. 300 +100 −50 XS2H-D421 * Stainless sintered roller 29.2±1.2 30.2±0.2 40±0.7 42 max. 53.2±0.8 * Stainless sintered roller The only difference in the shape for High-sensitivity and High-precision Switches is the set position marker plate. The only difference in the shape for High-sensitivity and High-precision Switches is the set position marker plate. Note: 1. Unless otherwise indicated, a tolerance of ±0.4 mm applies to all dimensions. 2. The following diagrams are for a indicator-equipped models. Model Operating force Release force Pretravel Overtravel Movement Differential OF RF PT OT MD High-sensitivity Switches Basic Switches Operating characteristics max. min. 13.34 N 1.18 N 15±5° 70° 12° min. max. High-precision Switches 13.34 N 1.18 N +2° 10° −1° 80° 7° 13.34 N 1.18 N +2° 5° 0° 80° 3° Operation indicator Switches Roller lever WLCA2-LD-N WLCA2-LE-N 17.5×7 dia. * Two, M3.5 R38 60 max. 53±1.5 41.5±1.5 40±1.5 25.4 13.1 12.7 Four, 5.2 dia. holes 25.4 (125) 14.7 M5 Allen-head bolt 58.7±0.2 68.7 Three, M4 5 21.6 (4.9) (15.1) JIS B 0202 G½ 30.2±0.2 40±0.7 * Stainless sintered roller 29.2±1.5 Four, M6 42 max. Depth: 15 min 53.2±0.8 Operating force Release force Pretravel Overtravel Movement Differential Note: 1. Unless otherwise indicated, a tolerance of ±0.4 mm applies to all dimensions. 36 Model WLCA2-LD-N WLCA2-LE-N max. min. 13.34 N 1.18 N 15±5° 70° 12° Operating characteristics OF RF PT OT MD min. max. WL-N/WLM-N Spatter-prevention Switches Switches with Roller Lever Actuators Switches with Screw Terminals Basic Switches WLCA2-@S-N High-sensitivity Switches WLG2-@S-N High-precision Switches 17.5×7 dia. * WLGCA2-@S-N Switches with Pre-wired Connectors WLCA2-@S-M1J-N 60 max. 53±1.5 41.5±1.5 40±1.5 25.4 13.1 12.7 Two, M3.5 R38 Two, M3.5 R38 12.7 Four, 5.2 dia. holes 25.4 M5 Allen-head bolt 14.7 (125) Four, 5.2 dia. holes 25.4 (125) 60 max. 53±1.5 41.5±1.5 40±1.5 25.4 13.1 17.5×7 dia. * 14.7 M5 Allen-head bolt Fluorine resin cap Three, M4 58.7±0.2 58.7±0.2 Three, M4 Fluorine resin cap 68.7 5 68.7 (4.9) (15.1) Four, M6 Depth: 15 min SC-1M 5 (4.9) (15.1) 30.2±0.2 40±0.7 21.6 29.2±1.2 42 max. 53.2±0.8 JIS B 0202 G½ 300 +100 −50 Four, M6 Depth: 15 min XS2H-D421 * Stainless sintered roller 29.2±1.2 30.2±0.2 40±0.7 The only difference in the shape for High-sensitivity and High-precision Switches is the set position marker plate. 42 max. 53.2±0.8 * Stainless sintered roller Switches with Sealed Top-roller Plungers Switches with Screw Terminals WLD28-@S-N Switches with Pre-wired Connectors WLD28-@S-M1J-N PT 14.3 dia.×5 * PT 13.1 12.9 Rubber cap (fluorine rubber) Rubber cap (fluorine rubber) 14.3 dia.×5 * 13.1 12.9 Two, M3.5 OP Two, M3.5 OP Four, 5.2 dia. holes 58.7±0.2 68.7 Three, M4 Four, 5.2 dia. holes 58.7±0.2 68.7 5 Three, M4 Four, M6 Depth: 15 min SC-1M 5 (15.1) 21.6 JIS B 0202 G½ (4.9) 30.2±0.2 29.2±1.2 40±0.7 42 max. Four, M6 Depth: 15 min 300 +100 −50 XS2H-D421 *Stainless sintered roller (15.1) 29.2±1.2 (4.9) 30.2±0.2 42 max. 40±0.7 *Stainless sintered roller Note: 1. Unless otherwise indicated, a tolerance of ±0.4 mm applies to all dimensions. 2. The above diagrams are for Indicator-equipped Switches. Actuator Operating characteristics Operating force Release force Pretravel Overtravel Movement Differential OF RF PT OT MD max. min. Operating position Total travel position OT TTP max. min. max. Switches with Roller Lever Actuators Switches with Sealed Toproller Plungers Basic Switches High-sensitivity Switches High-precision Switches 13.34 N 1.18 N 15±5° 70° 12° 13.34 N 1.18 N +2° 10° −1° 80° 7° 13.34 N 1.18 N +2° 5° 0° 80° 3° 16.67 N 4.41 N Max.1.7 mm 5.6 mm 1 mm — — — — — — 44±0.8 mm 39.5 mm 37 WL-N/WLM-N Long-life Switches Switches with Roller Lever Actuators Switches with Screw Terminals Basic Switches WLMCA2-LD-N High-sensitivity Switches WLMG2-LD-N High-precision Switches WLMGCA2-LD-N 60 max. 53±1.5 41.5±1.5 40±1.5 25.4 17.5 dia.×7 * Switches with Direct-wired Connectors Basic Switches WLMCA2-LDK13-N High-sensitivity Switches WLMG2-LDK13-N High-precision Switches WLMGCA2-LDK13-N 17.5 dia.×7 * 13.1 12.7 Two, M3.5 R38 14.7 25.4 Four, 5.2 dia. holes 14.7 M5 Allen-head bolt Fluorine resin cap 68.7 58.7±0.2 68.7 Three, M4 Three, M4 21.6 (15.1) Four, M6 Depth: 15 min (4.9) 30.2±0.2 5 12.5 (15.1) 29.2±1.2 JIS B 0202 G½ 29.2±1.2 30.2±0.2 53.2±0.8 40±0.7 *Stainless sintered roller Switches with Pre-wired Connectors Basic Switches WLMCA2-LD-M1J-N High-sensitivity Switches WLMG2-LD-M1J-N High-precision Switches WLMGCA2-LD-M1J-N 17.5 dia.×7 * 60 max. 53±1.5 41.5±1.5 40±1.5 25.4 The only difference in the shape for High-sensitivity and High-precision Switches is the set position marker plate. 13.1 12.7 Two, M3.5 Four, 5.2 dia. holes 25.4 M5 Allen-head bolt Fluorine resin cap 58.7±0.2 68.7 Three, M4 5 Four, M6 Depth: 15 min SC-1M 300 +100 −50 XS2H-D421 (15.1) 29.2±1.2 (4.9) 42 max. 30.2±0.2 40±0.7 53.2±0.8 *Stainless sintered roller The only difference in the shape for High-sensitivity and High-precision Switches is the set position marker plate. Note: 1. Unless otherwise indicated, a tolerance of ±0.4 mm applies to all dimensions. 2. The above diagrams are for Indicator-equipped Switches. Actuator Operating characteristics Operating force Release force Pretravel Overtravel Movement Differential 38 OF RF PT OT MD max. min. min. max. 42 max. 53.2±0.8 *Stainless sintered roller The only difference in the shape for High-sensitivity and High-precision Switches is the set position marker plate. 14.7 Four, M6 Depth: 15 min M12×1 (4.9) 42 max. 40±0.7 R38 25.4 M5 Allen-head bolt Fluorine resin cap 58.7±0.2 5 13.1 12.7 Two, M3.5 R38 Four, 5.2 dia. holes 60 max. 53±1.5 41.5±1.5 40±1.5 25.4 Switches with Roller Lever Actuators Basic Switches High-sensitivity Switches High-precision Switches 13.34 N 1.18 N 15±5° 70° 12° 13.34 N 1.18 N +2° 10° −1° 80° 7° 13.34 N 1.18 N +2° 5° 0° 80° 3° WL-N/WLM-N Actuators (Levers Only) Lever: Only rotating lever models are illustrated. WL-1A100 Standard Lever WL-1A115 Resin Roller 17.9 17.5 dia. × 7, sintered stainless steel roller 7.3-dia. mounting holes 12.6 WL-1A105 Double Nuts 7.3-dia. mounting holes 17.9 7.3-dia. mounting holes 12.6 Two, M5 Allenhead nut 11.4 and arm set screw 38 17.9 7.3-dia. mounting holes 54.8 7.3-dia. mounting 16 holes 24.9±0.8 19.7±0.8 17.5 dia. × 7, sintered stainless steel roller 7.3-dia. mounting holes 63 M5 Allen-head bolt 11.4 Adjustable lever: stainless steel WL-2A107 Double Nuts 24.9±0.8 19.7±0.8 17.5 dia. (length: 7) resin roller Adjustable lever: stainless steel Adjustable range: 25 to 89 105.75 17.5 dia. × 7, 24.9±0.8 sintered stainless M5 steel roller Allen-head 19.7±0.8 bolt Adjustable lever: stainless steel Adjustable range: 28 to 88 105.75 7.3-dia. mounting holes 7.3-dia. mounting holes M5 Allen-head bolt 12 16 12 16 12 16 79.8 M5 Allen-head bolt 11.4 17.5 dia. (length: 7) resin roller Adjustable lever: stainless steel 24.9±0.8 M5 Allen-head 19.7±0.8 bolt 23 23 Adjustable range: 25 to 140 105.75 7.3-dia. mounting holes 7.3-dia. mounting holes M5 Allen-head bolt 12.6 WL-2A108 Resin Roller 23 23 Adjustable range: 25 to 89 17.9 50 66.8 16 WL-2A111 Resin Roller M5 Allen-head bolt 11.4 17.5 dia. × 7, sintered stainless steel roller 25.7 16.6 16 WL-2A100 23.6 WL-1A300 Lever Length: 63 17.5 dia. × 15, sintered stainless steel roller 12.6 40.2±0.8 54.8 38 M5 Allen-head bolt 11.4 16 M5 Allen-head bolt 11.4 16 12.1 WL-1A200 Lever Length: 50 Roller Width: 15 17.5 dia. (length: 7) stainless steel roller 7.3-dia. mounting holes 38 54.8 17.5 dia. (length: 30) Nylon roller 16.9 38 54.8 M5 Allen-head bolt 11.4 WL-1A103S Spatter 17.5 dia. × 7, sintered stainless steel roller 16 16 WL-1A118 Nylon Roller: Roller Width: 30 mm 17 dia. (length: 6) bearing roller 12.6 38 54.8 M5 Allen-head bolt 11.4 16 17.9 17.5 dia. (length: 7) resin roller 7.3-dia. mounting holes 38 54.8 WL-1A400 Bearing Roller 155.75 Two, M5 Allen-head nut and arm set screw 6.2 (15.8) WL-2A122 WL-2A106 17.5 dia. × 7, M5 sintered stainless Allen-head steel roller bolt Adjustable lever: stainless steel 24.9±0.8 19.7±0.8 23 9.1 24.7±0.8 19.5±0.8 17.5 dia. × 7, sintered stainless steel roller 24.9±0.8 19.7±0.8 50 dia. (length: 6) Nylon roller 3 Adjustable lever: stainless steel 23 Adjustable range: 25 to 89 (10) R89.5 (10) 105.75 155.75 7.3-dia. mounting holes 15.9 * Can be installed on the rear side. Adjustable from 42 to 89 Three, 5.3 +0.2 0 dia. holes 7.3 dia. mounting holes (112) M5 Allen-head bolt 16 20 6.2 24.9±0.8 19.7±0.8 17.5 dia. × 7, sintered stainless steel roller WL-2A104 (21.8) Adjustable range: 25 to 140 7.3-dia. mounting holes WL-2A130 7.3-dia. mounting holes M5 Allen-head bolt 23 20 M5 Allen-head bolt 12 16 23 (15.8) Note: 1. Unless otherwise indicated, a tolerance of ±0.4 mm applies to all dimensions. Lever: Only rotating lever models are illustrated. 39 WL-N/WLM-N WL-2A110 WL-2A105 WL-1A106 WL-1A110 34.2 34.5 50 dia. (length: 15) Nylon roller 24.2 49 dia. rubber roller Material: NBR 24.4 50 dia. (length: 6) Nylon roller 6 35 dia. (length: 6) Nylon roller 20.1±0.8 20.1±0.8 R38 Adjustable from 41 to 78.5 23 122 M5 Allen-head bolt 7.3-dia. mounting holes R38 23 Adjustable from 41 to 89 M5 Allen-head bolt 16 M5 Allen-head bolt 7.3-dia. mounting holes 7.3 dia. mounting holes 16 11.5 11.5 M5 Allen-head bolt 7.3-dia. mounting holes 16 16 WL-4A100 WL-4A201 9 9 3-dia. stainless steel rod 7.3-dia. mounting holes M5 Allen-head bolt Adjustable from 25 to 140 160 WL-3A100 3.2-dia. stainless steel rod 2-dia. stainless steel for spring 13 Adjustable from 270 to 290 Adjustable from 350 to 380 7.3-dia. mounting holes M8 Allen-head set screw 3.2-dia. stainless steel rod Adjustable from 350 to 380 8 400±2 M5 Allen-head bolt 19 WL-3A106 Double Nut 400±2 Actuator's center of rotation M8 Allen-head set screw 8 M5 Allen-head bolt 11 65±2 7.5 6 11 65±2 7.5 6 11 7.3-dia. mounting 12.8 holes 11 WL-3A108 WL-3A200 WL-3A203 2.3-dia. operation rod 3.2-dia. stainless steel rod M5 13.4 Allen-head bolt 25.5 max. 7.3-dia. mounting 12.8 holes 9 8 dia. Cap Adjustable up to 141 417.5±2 8 437.5±2 450±4 680±0.4 Adhesive 7.3-dia. mounting 12.8 holes M5 Allen-head bolt 7.3-dia. mounting holes 7.5 25.5 max. WL-2A129 15.8 Marking (95) 11 7.5 6 13.4 WL-5A101 6.7 17.7 12.4 84 95.3 (108) 7.3 dia. 7.3 dia. mounting hole 10 15.9 20 M5 Allen-head bolt 22.1 13 24.6 max. WL-5A105 Two, 17.5 dia. × 7, sintered stainless steel rollers Two, 17.5 dia. × 7, sintered stainless steel rollers 17.7 6.7 12.4 1.3 11 WL-5A100 has a plastic roller 7.3 dia. R38 54.8 M5 Allen-head bolt 11 WL-5A102 has a plastic roller Note: 1. Unless otherwise indicated, a tolerance of ±0.4 mm applies to all dimensions. 2. When using the adjustable roller (rod) lever, make sure that the lever is facing downwards. Use caution, as telegraphing (the Switch turns ON and OFF repeatedly due to inertia) may occur. 40 17.7 12.4 90° 7.3 dia. R38 54.8 M5 Allen-head bolt 10 11.3 11 90° 90° Three, 5.2 dia. holes 7.3-dia. M5 mounting 7.5 Allen-head holes bolt WL-5A103 1.3 (18.5) M8 Allen-head set screw 11 7.5 6 M5 13 Allen-head bolt 24.6 max. Two, 17.5 dia. × 7, sintered stainless steel rollers 3 R8 19 12.5 dia. max. 2.3 dia. rod (95) 11 65±2 7.5 6 4-dia. stainless steel rod 7.3-dia. mounting holes M5 Allen-head bolt 160±1.5 470±4 12.5 dia. max. 13.4 25.5 max. WL-4A112 50 Adjustable from 650 to 660 Two, M5 Allenhead nut and arm set screw R38 54.8 M5 Allen-head bolt 11 WL-5A104 has a plastic roller WL-N/WLM-N Model Replacement Table WL WL-N WL WL-N WL WL-N WLCA2 WLCA2-N WLSD WLSD-N WLHAL5-LE WLCAL5-LE-N WL01CA2 WLCA2-N WL01SD WLSD-N WLHAL5-LD WLCAL5-LD-N WLH2 WLCA2-N WLSD2 WLSD2-N WLCA32-41LE WLCA32-41LE-N WL01H2 WLCA2-N WL01SD2 WLSD2-N WLCA32-41LD WLCA32-41LD-N WLG2 WLG2-N WLSD3 WLSD3-N WLCA32-42LE WLCA32-42LE-N WL01G2 WLG2-N WL01SD3 WLSD3-N WLCA32-43LE WLCA32-43LE-N WLCA2-2 WLCA2-2-N WLNJ WLNJ-N WLCA32-43LD WLCA32-43LD-N WL01CA2-2 WLCA2-2-N WL01NJ WLNJ-N WLD-LE WLD18-LE-N WLCA2-2N WLCA2-2N-N WLNJ-30 WLNJ-30-N WLD-LD WLD18-LD-N WL01CA2-2N WLCA2-2N-N WL01NJ-30 WLNJ-30-N WLD2-LE WLD28-LE-N WLGCA2 WLGCA2-N WLNJ-2 WLNJ-2-N WLD2-LD WLD28-LD-N WL01GCA2 WLGCA2-N WL01NJ-2 WLNJ-2-N WLD3-LE WLD38-LE-N WLCA2-7 WLCA2-7-N WLNJ-S2 WLNJ-S2-N WLD3-LD WLD38-LD-N WL01CA2-7 WLCA2-7-N WL01NJ-S2 WLNJ-S2-N WLD28-LE WLD28-LE-N WLCA2-8 WLCA2-8-N WLCA2-LE WLCA2-LE-N WLD28-LD WLD28-LD-N WL01CA2-8 WLCA2-8-N WLCA2-LD WLCA2-LD-N WLSD-LE WLSD-LE-N WLCA12 WLCA12-N WLH2-LE WLCA2-LE-N WLSD-LD WLSD-LD-N WL01CA12 WLCA12-N WLH2-LD WLCA2-LD-N WLSD2-LE WLSD2-LE-N WLH12 WLCA12-N WLG2-LE WLG2-LE-N WLSD2-LD WLSD2-LD-N WL01H12 WLCA12-N WLG2-LD WLG2-LD-N WLSD3-LE WLSD3-LE-N WLG12 WLG12-N WLCA2-2LE WLCA2-2LE-N WLSD3-LD WLSD3-LD-N WL01G12 WLG12-N WLCA2-2LD WLCA2-2LD-N WLNJ-LE WLNJ-LE-N WLCA12-2 WLCA12-2-N WLCA2-2NLE WLCA2-2NLE-N WLNJ-LD WLNJ-LD-N WL01CA12-2 WLCA12-2-N WLCA2-2NLD WLCA2-2NLD-N WLNJ-30LE WLNJ-30LE-N WLCA12-2N WLCA12-2N-N WLGCA2-LE WLGCA2-LE-N WLNJ-30LD WLNJ-30LD-N WL01CA12-2N WLCA12-2N-N WLGCA2-LD WLGCA2-LD-N WLNJ-2LE WLNJ-2LE-N WLCL WLCL-N WLCA2-7LE WLCA2-7LE-N WLNJ-2LD WLNJ-2LD-N WL01CL WLCL-N WLCA2-7LD WLCA2-7LD-N WLNJ-S2LE WLNJ-S2LE-N WLHL WLCL-N WLCA2-8LE WLCA2-8LE-N WLNJ-S2LD WLNJ-S2LD-N WL01HL WLCL-N WLCA2-8LD WLCA2-8LD-N WLCA2-LDK13 WLCA2-LDK13-N WLGL WLGL-N WLCA12-LE WLCA12-LE-N WLCA2-55LDK13 WLCA2-55LDK13-N WL01GL WLGL-N WLCA12-LD WLCA12-LD-N WLCA2-LDK43 WLCA2-LDK43-N WLCL-2 WLCL-2-N WLH12-LE WLCA12-LE-N WLCA2-55LDK43 WLCA2-55LDK43-N WLCL-2N WLCL-2N-N WLH12-LD WLCA12-LD-N WLD2-LDK13 WLD28-LDK13-N WL01CL-2N WLCL-2N-N WLG12-LE WLG12-LE-N WLD2-55LDK13 WLD28-55LDK13-N WLHAL4 WLCAL4-N WLG12-LD WLG12-LD-N WLD2-LDK43 WLD28-LDK43-N WLHAL5 WLCAL5-N WLCA12-2LE WLCA12-2LE-N WLD2-55LDK43 WLD28-55LDK43-N WLCA32-41 WLCA32-41-N WLCA12-2LD WLCA12-2LD-N WLH2-LDK13 WLCA2-LDK13-N WL01CA32-41 WLCA32-41-N WLCA12-2NLE WLCA12-2NLE-N WLH2-55LDK13 WLCA2-55LDK13-N WLCA32-42 WLCA32-42-N WLCA12-2NLD WLCA12-2NLD-N WLH2-LDK43 WLCA2-LDK43-N WLCA32-43 WLCA32-43-N WLCL-LE WLCL-LE-N WLH2-55LDK43 WLCA2-55LDK43-N WL01CA32-43 WLCA32-43-N WLCL-LD WLCL-LD-N WLG2-LDK13 WLG2-LDK13-N WLCA32-44 WLCA32-44-N WLHL-LE WLCL-LE-N WLG2-55LDK13 WLG2-55LDK13-N WL01CA32-44 WLCA32-44-N WLHL-LD WLCL-LD-N WLG2-LDK43 WLG2-LDK43-N WLD WLD18-N WLGL-LE WLGL-LE-N WLG2-55LDK43 WLG2-55LDK43-N WL01D WLD18-N WLGL-LD WLGL-LD-N WLGCA2-LDK13 WLGCA2-LDK13-N WLD2 WLD28-N WLCL-2LE WLCL-2LE-N WLGCA2-55LDK13 WLGCA2-55LDK13-N WL01D2 WLD28-N WLCL-2LD WLCL-2LD-N WLGCA2-LDK43 WLGCA2-LDK43-N WLD3 WLD38-N WLCL-2NLE WLCL-2NLE-N WLGCA2-55LDK43 WLGCA2-55LDK43-N WL01D3 WLD38-N WLCL-2NLD WLCL-2NLD-N WLCA2-LD-M1J WLCA2-LD-M1J-N WLD28 WLD28-N WLHAL4-LE WLCAL4-LE-N WLCA2-55LD-M1J WLCA2-55LD-M1J-N WL01D28 WLD28-N WLHAL4-LD WLCAL4-LD-N WLCA2-LD-M1GJ WLCA2-LD-M1GJ-N 41 WL-N/WLM-N WL 42 WL-N WL WL-N WL WL-N WLCA2-55LD-M1GJ WLCA2-55LD-M1GJ-N WLH2-55LE WLCA2-55LE-N WLGCA2-139LD3 WLGCA2-139LD3-N WLCA2-55LD-M1JB WLCA2-55LD-M1JB-N WLH2-139 WLCA2-139-N WLGCA2-140 Ask your OMRON representative. WLCA2-LD-DGJ03 WLCA2-LD-DGJ-N WLH2-140 WLCA2-140-N WLGCA2-140LD2 Ask your OMRON representative. WLCA2-55LD-DGJ03 WLCA2-55LD-DGJ-N WLH2-141 WLCA2-141-N WLGCA2-140LD3 Ask your OMRON representative. WLCA2-LD-DK1EJ03 WLCA2-LD-DK1EJ-N WLH2-141LD3 WLCA2-141LD3-N WLGCA2-141 WLGCA2-141-N WLCA2-55LD-DK1EJ03 WLCA2-55LD-DK1EJ-N WLH2-RP60 WLCA2-RP60-N WLGCA2-141LD3 WLGCA2-141LD3-N WLD2-LD-M1J WLD28-LD-M1J-N WLH2-RP60LD3 WLCA2-RP60LD3-N WLGCA2-RP60 WLGCA2-RP60-N WLD2-55LD-M1J WLD28-55LD-M1J-N WLH2-TH WLCA2-TH-N WLGCA2-RP60LD2 WLGCA2-RP60LD2-N WLD2-LD-M1GJ WLD28-LD-M1GJ-N WLH2-TC WLCA2-TC-N WLGCA2-RP60LD3 WLGCA2-RP60LD3-N WLD2-55LD-M1GJ WLD28-55LD-M1GJ-N WLH2-RP WLCA2-RP-N WLGCA2-TH WLGCA2-TH-N WLD2-55LD-M1JB WLD28-55LD-M1JB-N WLH2-P1 WLCA2-P1-N WLGCA2-TC WLGCA2-TC-N WLD2-LD-DGJ03 WLD28-LD-DGJ-N WLG2-55 WLG2-55-N WLGCA2-RP WLGCA2-RP-N WLD2-LD-DK1EJ03 WLD28-LD-DK1EJ-N WLG2-55LD WLG2-55LD-N WLCA12-55 WLCA12-55-N WLD2-55LD-DK1EJ03 WLD28-55LD-DK1EJ-N WLG2-55LE WLG2-55LE-N WLCA12-55LD WLCA12-55LD-N WLH2-LD-M1J WLCA2-LD-M1J-N WLG2-139 WLG2-139-N WLCA12-55LE WLCA12-55LE-N WLH2-LD-M1GJ WLCA2-LD-M1GJ-N WLG2-139LD3 WLG2-139LD3-N WLCA12-139 WLCA12-139-N WLH2-LD-DGJ03 WLCA2-LD-DGJ-N WLG2-140 WLG2-140-N WLCA12-140 WLCA12-140-N WLG2-LD-M1J WLG2-LD-M1J-N WLG2-140LD2 Ask your OMRON representative. WLCA12-141 WLCA12-141-N WLG2-LD-M1GJ WLG2-LD-M1GJ-N WLG2-140LD3 Ask your OMRON representative. WLCA12-RP60 WLCA12-RP60-N WLG2-55LD-M1GJ WLG2-55LD-M1GJ-N WLG2-141 WLG2-141-N WLCA12-TH WLCA12-TH-N WLG2-LD-M1JB WLG2-LD-M1JB-N WLG2-141LD2 WLG2-141LD2-N WLCA12-TC WLCA12-TC-N WLG2-55LD-M1JB WLG2-55LD-M1JB-N WLG2-141LD3 WLG2-141LD3-N WLCA12-RP WLCA12-RP-N WLG2-LD-DGJ03 WLG2-LD-DGJ-N WLG2-RP60 WLG2-RP60-N WLCA12-P1 WLCA12-P1-N WLG2-55LD-DGJ03 WLG2-55LD-DGJ-N WLG2-RP60LD2 WLG2-RP60LD2-N WLH12-TH WLCA12-TH-N WLG2-LD-DK1EJ03 WLG2-LD-DK1EJ-N WLG2-RP60LD3 WLG2-RP60LD3-N WLH12-TC WLCA12-TC-N WLG2-55LD-DK1EJ03 WLG2-55LD-DK1EJ-N WLG2-TH WLG2-TH-N WLH12-RP WLCA12-RP-N WLGCA2-LD-M1J WLGCA2-LD-M1J-N WLG2-TC WLG2-TC-N WLH12-P1 WLCA12-P1-N WLGCA2-55LD-M1J WLGCA2-55LD-M1J-N WLG2-RP WLG2-RP-N WLG12-TH WLG12-TH-N WLGCA2-LD-M1GJ WLGCA2-LD-M1GJ-N WLG2-P1 WLG2-P1-N WLG12-TC WLG12-TC-N WLGCA2-55LD-M1JB WLGCA2-55LD-M1JB-N WLCA2-255 WLCA2-255-N WLG12-RP WLG12-RP-N WLGCA2-55LD-DGJ03 WLGCA2-55LD-DGJ-N WLCA2-255LD WLCA2-255LD-N WLG12-P1 WLG12-P1-N WLCA2-55 WLCA2-55-N WLCA2-255LE WLCA2-255LE-N WLCA12-2TH WLCA12-2TH-N WLCA2-55LD WLCA2-55LD-N WLCA2-2139 WLCA2-2139-N WLCA12-2TC WLCA12-2TC-N WLCA2-55LE WLCA2-55LE-N WLCA2-2139LD2 WLCA2-2139LD2-N WLCA12-2NTH WLCA12-2NTH-N WLCA2-139 WLCA2-139-N WLCA2-2139LD3 WLCA2-2139LD3-N WLCA12-2NTC WLCA12-2NTC-N WLCA2-139LD2 WLCA2-139LD2-N WLCA2-2RP60 WLCA2-2RP60-N WLCL-55 WLCL-55-N WLCA2-139LD3 WLCA2-139LD3-N WLCA2-2RP60LD2 WLCA2-2RP60LD2-N WLCL-55LD WLCL-55LD-N WLCA2-140 WLCA2-140-N WLCA2-2RP60LD3 WLCA2-2RP60LD3-N WLCL-139 WLCL-139-N WLCA2-140LD2 Ask your OMRON representative. WLCA2-2TH WLCA2-2TH-N WLCL-140 WLCL-140-N WLCA2-140LD3 Ask your OMRON representative. WLCA2-2TC WLCA2-2TC-N WLCL-RP60 WLCL-RP60-N WLCA2-141 WLCA2-141-N WLCA2-2N55 WLCA2-2N55-N WLCL-TH WLCL-TH-N WLCA2-141LD2 WLCA2-141LD2-N WLCA2-2N55LD WLCA2-2N55LD-N WLCL-TC WLCL-TC-N WLCA2-141LD3 WLCA2-141LD3-N WLCA2-2N55LE WLCA2-2N55LE-N WLCL-RP WLCL-RP-N WLCA2-RP60 WLCA2-RP60-N WLCA2-2N139 WLCA2-2N139-N WLCL-P1 WLCL-P1-N WLCA2-RP60LD2 WLCA2-RP60LD2-N WLCA2-2N140 WLCA2-2N140-N WLHL-TH WLCL-TH-N WLCA2-RP60LD3 WLCA2-RP60LD3-N WLCA2-2NTH WLCA2-2NTH-N WLHL-TC WLCL-TC-N WLCA2-TH WLCA2-TH-N WLCA2-2NTC WLCA2-2NTC-N WLHL-RP WLCL-RP-N WLCA2-TC WLCA2-TC-N WLGCA2-55 WLGCA2-55-N WLHL-P1 WLCL-P1-N WLCA2-RP WLCA2-RP-N WLGCA2-55LD WLGCA2-55LD-N WLGL-TH WLGL-TH-N WLCA2-P1 WLCA2-P1-N WLGCA2-55LE WLGCA2-55LE-N WLGL-TC WLGL-TC-N WLH2-55 WLCA2-55-N WLGCA2-139 WLGCA2-139-N WLGL-RP WLGL-RP-N WLH2-55LD WLCA2-55LD-N WLGCA2-139LD2 WLGCA2-139LD2-N WLGL-P1 WLGL-P1-N WL-N/WLM-N WL WL-N WL WL-N WL WL-N WLCL-2TH WLCL-2TH-N WLG2-LEAS WLG2-LEAS-N WLRCL WLCL-2TC WLCL-2TC-N WLCA2-LDAS WLCA2-LDAS-N WLRG2 WLRG2-N WLCL-2RP WLCL-2RP-N WLH2-LDAS WLCA2-LDAS-N WLRCA2-2 WLRCA2-2-N WLCL-2NTH WLCL-2NTH-N WLG2-LDAS WLG2-LDAS-N WLRCA2-2N WLRCA2-2N-N WLCL-2NTC WLCL-2NTC-N WLCA2-LES WLCA2-LES-N WLRCA32 WLRCA32-N WLD2-55 WLD28-55-N WLH2-LES WLCA2-LES-N WLRCA2-LDS WLRCA2-LDS-N WLD2-55LD WLD28-55LD-N WLG2-LES WLG2-LES-N WLRH2-LES WLRCA2-LES-N WLD2-55LE WLD28-55LE-N WLGCA2-LES WLGCA2-LES-N WLRH2-LDS WLRCA2-LDS-N WLD2-139 WLD28-139-N WLCA2-LDS WLCA2-LDS-N WLRG2-LDS WLRG2-LDS-N WLD2-RP60 WLD28-RP60-N WLH2-LDS WLCA2-LDS-N WLRGCA2-LES WLRGCA2-LES-N WLD2-TH WLD28-TH-N WLG2-LDS WLG2-LDS-N WLD2-TC WLD28-TC-N WLGCA2-LDS WLGCA2-LDS-N WLD2-RP WLD28-RP-N WLD28-LES WLD28-LES-N WLD28-55 WLD28-55-N WLD28-LDS WLD28-LDS-N WLD28-55LD WLD28-55LD-N WLMCA2-LD WLMCA2-LD-N WLD28-55LE WLD28-55LE-N WLMCA2-LDK13A WLMCA2-LDK13A-N WLD28-139 WLD28-139-N WLMCA2-LDK13 WLMCA2-LDK13-N WLD28-140 WLD28-140-N WLMCA2-LDK43A WLMCA2-LDK43A-N WLD28-RP60 WLD28-RP60-N WLMCA2-LDK43 WLMCA2-LDK43-N WLD28-TH WLD28-TH-N WLMCA2-LD-M1J WLMCA2-LD-M1J-N WLD28-RP WLD28-RP-N WLMCA2-LD-DGJ03 WLMCA2-LD-DGJ-N WLSD-55 WLSD-55-N WLMGCA2-LD WLMGCA2-LD-N WLSD-55LD WLSD-55LD-N WLMGCA2-LDK13A WLMGCA2-LDK13A-N WLSD-139 WLSD-139-N WLMGCA2-LDK13 WLMGCA2-LDK13-N WLSD-RP60 WLSD-RP60-N WLMGCA2-LDK43A WLMGCA2-LDK43A-N WLSD-TH WLSD-TH-N WLMGCA2-LDK43 WLMGCA2-LDK43-N WLSD-TC WLSD-TC-N WLMGCA2-LD-M1J WLMGCA2-LD-M1J-N WLSD-RP WLSD-RP-N WLMH2-LD WLMCA2-LD-N WLSD2-55 WLSD2-55-N WLMH2-LDK13A WLMCA2-LDK13A-N WLSD2-55LD WLSD2-55LD-N WLMH2-LDK13 WLMCA2-LDK13-N WLSD2-139 WLSD2-139-N WLMH2-LDK43A WLMCA2-LDK43A-N WLSD2-140 WLSD2-140-N WLMH2-LDK43 WLMCA2-LDK43-N WLSD2-RP60 WLSD2-RP60-N WLMH2-LD-M1J WLMCA2-LD-M1J-N WLSD2-TH WLSD2-TH-N WLMH2-LD-DGJ03 WLMCA2-LD-DGJ-N WLSD2-TC WLSD2-TC-N WLMG2-LD WLMG2-LD-N WLSD2-RP WLSD2-RP-N WLMG2-LDK13A WLMG2-LDK13A-N WLNJ-55 WLNJ-55-N WLMG2-LDK13 WLMG2-LDK13-N WLNJ-55LD WLNJ-55LD-N WLMG2-LDK43A Ask your OMRON representative. WLNJ-139 WLNJ-139-N WLMG2-LDK43 WLMG2-LDK43-N WLNJ-140 WLNJ-140-N WLMG2-LD-M1J WLMG2-LD-M1J-N WLNJ-RP60 WLNJ-RP60-N WLMG2-LD-DGJ03 WLMG2-LD-DGJ-N WLNJ-TH WLNJ-TH-N WLRCA2 WLRCA2-N WLNJ-TC WLNJ-TC-N WLRGCA2 WLRGCA2-N WLNJ-RP WLNJ-RP-N WLRG2 WLRG2-N WLNJ-255 WLNJ-255-N WLRH2 WLRCA2-N WLNJ-255LD-N WLRCA2-2 WLRCA2-2-N WLNJ-2140 WLNJ-2140-N WLRCA2-2N WLRCA2-2N-N WLNJ-2RP60 WLNJ-2RP60-N WLRCA2 WLRCA2-N WLNJ-2TC Ask your OMRON representative. WLRG2 WLRG2-N WLNJ-2RP WLNJ-2RP-N WLRH2 WLRCA2-N WLCA2-LEAS WLCA2-LEAS-N WLRCA2-2 WLRCA2-2-N WLH2-LEAS WLCA2-LEAS-N WLRCA2-2N WLRCA2-2N-N WLNJ-255LD WLRCA2-N 43 WL-N/WLM-N Safety Precautions Precautions for Safe Use • Be sure to ground. If not, there is the possibility that electrical shock occurs. • Do not touch charged switch terminals while the switch has carry current, otherwise there is the possibility that electrical shock occurs. • Do not disassemble the limit switch or touch inside of it under supplying power, otherwise there is the possibility that electrical shock occurs. • Do not touch the wire or rod type actuator in order to prevent injury. • Connect a fuse which has 1.5 to 2 times higher breaking current than the switch rated current to the switch in series in order to prevent the switch from short-circuit damage. On the occasion when using the switch with GB ratings, use a 10A fuse that complies IEC60269, either type gG. • The durability of switch is depends on the operating condition. Be sure to check the condition with actual using condition before using, and use with the number of times of operating without a performance problem. • Do not drop the switch. Otherwise, there is the possibility that the switch functions may be spoiled. • Do not connect a Single Limit Switch to two power supplies that are different in polarity or type. • Be sure to keep the load current less than the rated value. Otherwise, there is the possibility that the switch may be damage and/or burnout. • Minimum operating load: 5 VDC 1 mA, resistive load, P level Note: The P level indicates the standard malfunction level at a reliability level of 60% (λ60). (JISC5003) λ60 = 0.1 × 10-6 per operation, which indicates an estimated malfunction of 1 out of every 10,000,000 operations at a reliability level of 60%. • Do not use the Switch by itself in atmospheres containing flammable or explosive gases. Arcs and heating resulting from switching may cause fire or explosion. • Be sure to prevent the foreign materials such like a scrapped cable intrusion in to the switch when wiring. Otherwise, there is the possibility of spoiling the normal operation. • Never wire to the wrong terminals. • Do not store or use the switch with following place. Where the temperature fluctuates greatly Where the humidity is very high and condensation may occur. Where the vibration is too much Where receiving direct sunshine. Where receiving salty wind. • Do not disassemble and/or modify the switch at anytime. Otherwise, there is the possibility of spoiling the normal operation. • Do not apply the force such like deformation and/or degeneration to the switch. Otherwise, there is the possibility that the switch functions may be spoiled. 44 Precautions for Correct Use Environment • Take special care to use where there is fine powder, mud and/or foreign materials stacking. And check the condition with actual using condition before using. Then use without a performance problem. • This switch is only for indoor use. If it is used in outdoor, it may be cause of switch failure. • Do not keep the Switch in locations with corrosive gas, such as sulfuric gas (H2S or SO2), ammonium gas (NH3), nitric gas (HNO3), or chlorine gas (Cl2), or high temperature and humidity. Otherwise, contact failure or corrosion damage may result. • Seal material may deteriorate if a Switch is used outdoor or where subject to special cutting oils, solvents, or chemicals. Always appraise performance under actual application conditions and set suitable maintenance and replacement periods. • Install Switches where they will not be directly subject to cutting chips, dust, or dirt. The Actuator and Switch must also be protected from the accumulation of cutting chips or sludge. Not Suitable Suitable • Constantly subjecting a Switch to vibration or shock can result in wear, which can lead to contact interference with contacts, operation failure, reduced durability, and other problems. Excessive vibration or shock can lead to false contact operation or damage. Install Switches in locations not subject to shock and vibration and in orientations that will not produce resonance. • The Switches have physical contacts. Using them in environments containing silicon gas will result in the formation of silicon oxide (SiO2) due to arc energy. If silicon oxide accumulates on the contacts, contact interference can occur. If silicon oil, silicon filling agents, silicon cables, or other silicon products are present near the Switch, suppress arcing with contact protective circuits (surge killers) or remove the source of silicon gas. Installing the Switch • To install the Switch, make a mounting panel, as shown in the following diagram, and tighten screws using the correct torque. Front Mountig : Four, 5.2 +0.2 0 dia. holes or M5 tapped holes 58.7±0.15 Rear Mountig : Four, 6.2 +0.2 0 dia. holes 30.2 ±0.15 WL-N/WLM-N Tightening Torque Overtravel Markers • If screws are too loose they can lead to an early malfunction of the Switch, so ensure that all screws are tightened using the correct torque. • In particular, when changing the direction of the Head, make sure that all screws are tightened again to the correct torque. Do not allow foreign objects to fall into the Switch. (1) (3) (6) • All Switches with Roller Lever Actuators except for Switches with Fork Lever Locks and Low-temperature Switches have a set position marker plate. • To allow the roller lever type actuator to travel properly, set the roller lever according to the dog or cam stroke so that the arrowhead of the lever is positioned within overtravel markers as shown. Head (4) Screw down Arrowhead (2) Excessive OT Setting range Shortage OT Setting range Excessive OT (5) No. Type Torque Screw type Head mounting screw 0.78 to 0.88 N•m M3.5 screw (2) Cover mounting screw 1.18 to 1.37 N•m M4 screw (3) Allen-head bolt (for securing the roller lever) 4.90 to 5.88 N•m M5 hexagon socket head cap screw (3) Allen-head bolt (for securing the adjustable rod lever) 0.88 to 1.08 N•m M8 hexagon socket set screw (4) Terminal screw 0.59 to 0.78 N•m M3.5 screw (5) Connector 1.77 to 2.16 N•m G1/2orPg13.5orM20or 1/2-14NPT (6) Unit mounting screw 4.90 to 5.88 N•m M5 hexagon socket head cap screw (1) Wring In the case of mounting screw • Use M3.5-nylon insulation covered crimp terminals (round type) for wiring. Ex.) V1.25-M3.5(RAP1.25-3.5) (J.S.T. Mfg. Co.,Ltd.) • Appropriate wire size is AWG16 (1.25mm2). • Do not supply electric power when wiring. Otherwise electric shock may result. • Do not pull out the wires with excessive force. It may cause of coming off the wire. • Use crimp terminals for wiring. • In the case of lump unit, to avoid interference between lump unit and crimp terminals, wire according to right wiring figure. Attach the lump unit spring to terminal screw certainly otherwise itÅfs possible to be destroyed or shorted. • The ground terminal is only installed on models with ground terminals. In the case of prewired connecter and direct connecter • Holding the connecter certainly when pulling connecter. • Don’t pull the cable holding it. How to handle Connectors • Tighten the connector with the appropriate torque to prevent deformation. • Use the OMRON type SC connector series, which is prepared separately, suitable for outer diameter of cable and inner diameter of seal rubber. • Make sure to wrap the connector with the seal tape, except the connector which has O-ring, to keep the sealability. • To conform to CSA, use a CSA certified water tight treated conduit hub. • Even when the connector is assembled and set correctly, the end of the cable and the inside of the Switch may come in contact. This can lead to malfunction, leakage current, or fire, so be sure to protect the end of the cable from splashes of oil or water and corrosive gases. Microload Applications • The switch contacts can be used both for standard loads and microloads, but once a contact has been used to open and close a load it can no longer be used for lower loads. Doing so will damage the contact surface and reduce contact reliability. • If an inrush current or other sudden load occurs during a switch operation, the switch will begin to degrade severely which can result in reduced durability. Use a contact protection circuit if required. Indicator Indicator-equipped switch has contacts and indicator in parallel. When contacts are open, leakage current flows through the indicator circuit and may cause load's malfunction. Please check the load's OFF current before use the indicatorequipped switch. Leakage current may cause load malfunction (i.e., the load may remain ON). Make sure that the load operating current is higher than the leakage current. For countermeasures, refer to technical support on your OMRON website. Terminal Plate • By using the Terminal Plate (sold separately), as shown in the following diagram, the Switch can be used as a single-polarity double-break switch. Changing direction of the head Attach the Terminal Plate so that the “COM” mark is oriented as shown on the left. • By removing the screws in the two corners of the head, the head can be set any of four directions. Be sure to change the plunger for internal operations at the same time. Built-in Switch • Do not remove or replace the built-in switch. Terminal Plate Model WL-N TERMINAL PLATE Terminal Plate Mounting Diagram (with Two Terminal Screws Removed) 45 WL-N/WLM-N Using a WL@-2N Switch Mounted from the Side If you replace a previous Switch with a WL@-2N-N Switch, a Mounting Plate (sold separately) is available to maintain mounting compatibility. If you use the Mounting Plate, the Switch mounting holes and actuator position will be compatible. (The position of the dog will not need to be changed.) • With a roller actuator, the dog must touch the actuator at a right angle. The actuator or shaft may deform or break if the dog touches the actuator (roller) at an oblique angle. Incorrect Correct Dog Dog 64 58.7 Mounting Plate Plate mounting bolts (2) Set contents • Make sure that the actuator does not exceed the OT (overtravel) range, otherwise the Limit Switch may malfunction. When mounting the Limit Switch, be sure to adjust the Limit Switch carefully while considering the whole movement of the actuator. Operating body 23 30.2 WL@-2N Mounting Plate Replacing a Switch with the WL@-2N-N Plate (1) Model PT (Pretravel) Switch mounting bolts (2) Install a stopper. WLN-P001 70% of 100% of rated OT rated OT Operation • Carefully determine the position and shape of the dog or cam so that the actuator will not abruptly snap back, thus causing shock. In order to operate the Limit Switch at a comparatively high speed, use a dog or cam that keeps the Limit Switch turned ON for a sufficient time so that the relay or valve will be sufficiently energized. • The method of operation, the shape of the cam or dog, the operating frequency, and the travel after operation have a large influence on the durability and operating accuracy of the Limit Switch. The cam or dog must be smooth in shape. Incorrect Correct FP (Free position) OP (Operating position) OT (Overtravel) TTP (Total travel position) Optimum setting range Distance to the optimum setting range. Reference line • The Limit Switch may soon malfunction if the OT is excessive. Therefore, adjustments and careful consideration of the position of the Limit Switch and the expected OT of the operating body are necessary when mounting the Limit Switch. Correct Snapped back Abruptly actuated Incorrect Stopper Correct • When using a pin-plunger actuator, make sure that the stroke of the actuator and the movement of the dog are located along a single straight line. Incorrect Snapped back Abruptly Correct actuated Operating body Operating body • Appropriate force must be imposed on the actuator by the cam or dog in both rotary operation and linear operation. If the dog touches the lever as shown below, the operating position will not be stable. Incorrect Dog Correct Dog Others • Unbalanced force must not be imposed on the actuator. Otherwise, wear and tear on the actuator may result. Incorrect Dog Roller 46 Correct Dog Roller • For long term (over a year) storage, check according to Operating characteristics, Contact resistance and Dielectric strength at least. And check with using condition. • The durability of the Switch is greatly affected by operating conditions. Evaluate the Switch under actual working conditions before permanent installation and use the Switch within a number of switching operations that will not adversely affect the SwitchÅfs performance. WL-N/WLM-N Using the Switches Item Applicable models and Actuators Changing the Installation Position of the Actuator By loosening the Allen-head bolt on the actuator lever, the position of the actuator can be set anywhere within the 360°. With Indicator-equipped Switches, the actuator lever comes in contact with the top of the indicator cover, so use caution when rotating and setting the lever. When the lever only moves forwards and backwards, it will not contact the lamp cover. (This does not apply to Long-life Switches.) Roller Levers: (WLCA2-N, WLCA2-2-N, WLCA2-2N-N, WLG2-N, WLCA2-7-N, WLCA2-8-N, WLGCA2-N, WLMCA2-N, WLMG2-N, WLMGCA2-N) Adjustable Roller Levers: (WLCA12-N, WLCA12-2-N, WLCA12-2N-N, WLG12-N) Adjustable rod lever: (WLCL-N, WLCL-2-N, WLCL-2N-N, WLGL-N, WLCAL4-N, WLCAL5-N) Changing the Orientation of the Head By removing the two screws of the Head, the Head can be set in any of the four directions. Be sure to change the plunger for internal operations at the same time. The roller plunger can be set in either of two positions at 90° Roller Levers: (WLCA2-N, WLCA2-2-N, WLCA2-2N-N, WLG2-N, WLCA2-7-N, WLCA2-8-N, WLGCA2-N, WLMCA2-N, WLMG2-N, WLMGCA2-N) Adjustable Roller Levers: (WLCA12-N, WLCA12-2-N, WLCA12-2N-N, WLG12-N) Adjustable rod lever: (WLCL-N, WLCL-2-N, WLCL-2N-N, WLGL-N, WLCAL4-N, WLCAL5-N) Horizontal plunger (WLSD@-N) Sealed top-roller plunger (WLD28-N) Note: Does not include the -RP60 Series or -141 Series. Details Loosen the Allen-head bolt, set the actuator's position and then tighten the bolt again. Head Loosen the screws. p Changing the Operating Direction By removing the Head on models which can operate on one-side only, and then changing the direction of the operational plunger, one of three operating directions can be selected. Roller Levers: (WLCA2-N, WLCA2-2-N, WLCA2-2N-N, WLG2-N, WLCA2-7-N, WLCA2-8-N, WLGCA2-N, WLMCA2-N, WLMG2-N, WLMGCA2-N) Adjustable Roller Levers: (WLCA12-N, WLCA12-2-N, WLCA12-2N-N, WLG12-N) Adjustable rod lever: (WLCL-N, WLCL-2-N, WLCL-2N-N, WLGL-N, WLCAL4-N, WLCAL5-N) The output of the Switch will be changed, regardless of which direction the lever is pushed. Operating Operating Operation in both directions Installing the Roller on the Inside By installing the roller lever in the opposite direction, the roller can be installed on the inside. (Set so that operation can be completed within a 180° level range.) Roller Levers: (WLCA2-N, WLCA2-2-N, WLCA2-2N-N, WLG2-N, WLCA2-7-N, WLCA2-8-N, WLGCA2-N, WLMCA2-N, WLMG2-N, WLMGCA2-N) Fork lever lock: (WLCA32-4@-N) Note: Except for Switches with variable roller levers. The output of the Switch will only be changed when the lever is pushed in one direction. Not operating Operating Clockwise operation Operating Not operating Counterclockwise operation Loosen the Allen-head bolt. 47 WL-N/WLM-N Item Applicable models and Actuators Details Adjustment range radius: 24 to 140 mm Adjusting the Length of the Rod or Lever The length of the rod or lever can be adjusted by loosening the Allen-head bolt. Adjustable Roller Levers: (WLCA12-N, WLCA12-2-N, WLCA12-2N-N, WLG12-N) Adjustable rod lever: (WLCL-N, WLCL-2-N, WLCL-2N-N, WLGL-N, WLCAL4-N) Loosen this Allen-head bolt and adjust the length of the lever. Adjustment range radius: 25 to 89 mm Adjustable Roller Levers: Selecting the Roller Position There are four types of Switches with Fork lever lock: Fork Lever Locks for use depending on (WLCA32-4@-N) the roller position. Loosen this Allen-head bolt and adjust the length of the rod. Adjustable Rod Levers: WLCA32-41-N WLCA32-43-N WLCA32-42-N WLCA32-44-N An explanation of the operation of fork lever locks is provided after this table. Operation of Fork Lever Locks A Switch with a Fork Lever Lock is constructed so that the dog pushes the lever to invert the output and this inverted state is maintained even after the dog moves on. If the dog then pushes the lever from the opposite direction, the lever will return to its original position. Example NC terminal: ON 48 NO terminal: ON NO terminal: ON WL-N/WLM-N Limit Switch Connectors Connectors (SC Series) Cabtire cables and flexible tubes with various diameters are used to connect machine tools and controllers with Limit Switches. To ensure the watertightness of the edges of the conduits, use an SC Connector that is suitable for the external diameter of cable and model of Limit Switch. Ordering Information Connector for Cabtire Cable Conduit Applicable cable Cabtire cable (generalpurpose) JIS B 0202 G½ Cabtire cable (anticorrosive) ½-14NPT Cabtire cable Inner diameter (D) of seal rubber 7 mm 9 mm 12.5 mm 14 mm 11 mm 7 mm 9 mm 12.5 mm 14 mm 11 mm 7 mm 9 mm 12.5 mm 14 mm 11 mm External diameter of cable Min. Max. 5.5 mm 7.5 mm 7.5 mm 9.5 mm 11 mm 13 mm 12 mm 14 mm 9 mm 11 mm 5.5 mm 7.5 mm 7.5 mm 9.5 mm 11 mm 13 mm 12 mm 14 mm 9 mm 11 mm 5.5 mm 7.5 mm 7.5 mm 9.5 mm 11 mm 13 mm 12 mm 14 mm 9 mm 11 mm Model SC-1M SC-2M SC-3M SC-4M SC-5M SC-21 SC-22 SC-23 SC-24 SC-25 SC-1PT SC-2PT SC-3PT SC-4PT SC-5PT Applicable model WL-N, D4A-@N, D4B-@N, ZE, ZV, ZV2, XE, XV, XV2 D4A-@N Note: Please use sealling tape with SC Connectors. SC-1M to SC-5M, however, are provided with an O-ring (NBR) and therefore sealing tape is not necessary to ensure a proper seal. Simple Connectors (Not Suitable for Locations Subject to Oil or Water) Conduit Applicable cable JIS B 0202 G½ Pg13.5 JIS B 0202 G½ Cabtire cable Inner diameter (D) of seal rubber External diameter of cable Min. Max. Model 10.6 mm 8.5 mm 10.5 mm SC-P2 9.6 mm 7.5 mm 9.5 mm SC-P3 9 mm 7.5 mm 9 mm SC-6 Applicable model WL-N, D4A-@N, D4B-@N, ZE, ZV, ZV2, XE, XV, XV2 WL@-G-N WL-N, D4A-@N, D4N *, D4N-@R *, D4B-@N, ZE, ZV, ZV2, XE, XV, XV2 Note: Simple connector are made of resin. If more sealing capability is required, use one of SC-1M to SC-5M, which have metal casings. Models marked with an asterisk (*) however, can only be used with resin connectors. 49 WL-N/WLM-N Dimensions and Structure (Unit: mm) Connectors for Cabtire Cable As for models without an O-ring, please use sealing tape with SC Connectors. Metal Models without O-ring G½ SC-21 to 25 JIS B 0202 G½ 14.6 dia. *E 15 4.8 9 24 14 dia. 27.7 29.3 Ball head lock nut (brass and nickel plating) Washer (stainless steel) Sealing rubber (nitrile rubber) Connector (brass and nickel plating) *D (34) Metal Models with O-ring G½ SC-1M to 5M 14.6 dia. *E 15 JIS B 0202 G½ 5 9 29.3 27 14 dia. Ball head lock nut (zinc die-cast and zinc plating) Washer (stainless steel) *D 30 Sealing rubber (nitrile rubber) (34) Metal Models without O-ring ½-14NPT (U.S.-standard screws) SC-1PT to 5PT 14.6 dia. 14 dia. 15 Sealing rubber (nitrile rubber) Connector (zinc die-cast and zinc plating) 5 14 29.3 ½-14NPT 24 14 dia. Ball head lock nut (zinc die-cast and zinc plating) Washer (stainless steel) Sealing rubber (nitrile rubber) Connector (zinc die-cast and zinc plating) *D 27.7 (39) Note: Dimensions not shown in the above diagrams have a variation of ±0.4 mm. Simple Connectors (Not Suitable for Locations Subject to Oil or Water) Resin Models G½ SC-P2 15 22 5 18 dia. 12.6 dia. 25.4 Resin Models Pg13.5 SC-P3 15.5 5 21 Pg13.5 1 22.5 12 9 12 5 9 Note: Dimensions not shown in the above diagrams have a variation of ±0.4 mm. * Diameter of Part Marked with Asterisk SC-21, -1M, -1PT SC-22, -2M, -2PT SC-23, -3M, -3PT SC-24, -4M, 4PT SC-25, -5M, -5PT SC-6 50 Internal diameter (E) of washer 10.4 mm 13.2 mm 14.6 mm 14.6 mm 13.2 mm 10 mm Ball head lock nut (polyacetal resin) Washer (ferrous metal and zinc plating) *D G½ Inner diameter (D) of sealed rubber 7 mm 9 mm 12.5 mm 14 mm 11 mm 9 mm 4.5 Hexagonal nut (polyacetal resin) Conduit washer (ferrous metal and zinc plating) Ring (chloroprene rubber) Conduit washer (ferrous metal and zinc plating) 18 dia. 9.6 dia. 26 Model Hexagonal nut (polyacetal resin) 18 dia. 10.6 dia. (30.6) 10 9 4.5 Ring (chloroprene rubber) 18 dia. 12 dia. 23.5 Resin Models G½ SC-6 JIS B 0202 1 G½ Applicable cable 5.5 to 7.5-mm dia. 7.5 to 9.5-mm dia. 11 to 13-mm dia. 12 to 14-mm dia. 9 to 11-mm dia. 7.5 to 9-mm dia. M20 × 1.5 Sealing rubber (nitrile rubber) Connector (polyacetal resin) Terms and Conditions of Sale 1. Offer; Acceptance. These terms and conditions (these "Terms") are deemed part of all quotes, agreements, purchase orders, acknowledgments, price lists, catalogs, manuals, brochures and other documents, whether electronic or in writing, relating to the sale of products or services (collectively, the "Products") by Omron Electronics LLC and its subsidiary companies (“Omron”). Omron objects to any terms or conditions proposed in Buyer’s purchase order or other documents which are inconsistent with, or in addition to, these Terms. 2. Prices; Payment Terms. All prices stated are current, subject to change without notice by Omron. Omron reserves the right to increase or decrease prices on any unshipped portions of outstanding orders. Payments for Products are due net 30 days unless otherwise stated in the invoice. 3. Discounts. Cash discounts, if any, will apply only on the net amount of invoices sent to Buyer after deducting transportation charges, taxes and duties, and will be allowed only if (i) the invoice is paid according to Omron’s payment terms and (ii) Buyer has no past due amounts. 4. Interest. Omron, at its option, may charge Buyer 1-1/2% interest per month or the maximum legal rate, whichever is less, on any balance not paid within the stated terms. 5. Orders. Omron will accept no order less than $200 net billing. 6. Governmental Approvals. Buyer shall be responsible for, and shall bear all costs involved in, obtaining any government approvals required for the importation or sale of the Products. 7. Taxes. All taxes, duties and other governmental charges (other than general real property and income taxes), including any interest or penalties thereon, imposed directly or indirectly on Omron or required to be collected directly or indirectly by Omron for the manufacture, production, sale, delivery, importation, consumption or use of the Products sold hereunder (including customs duties and sales, excise, use, turnover and license taxes) shall be charged to and remitted by Buyer to Omron. 8. Financial. If the financial position of Buyer at any time becomes unsatisfactory to Omron, Omron reserves the right to stop shipments or require satisfactory security or payment in advance. If Buyer fails to make payment or otherwise comply with these Terms or any related agreement, Omron may (without liability and in addition to other remedies) cancel any unshipped portion of Products sold hereunder and stop any Products in transit until Buyer pays all amounts, including amounts payable hereunder, whether or not then due, which are owing to it by Buyer. Buyer shall in any event remain liable for all unpaid accounts. 9. Cancellation; Etc. Orders are not subject to rescheduling or cancellation unless Buyer indemnifies Omron against all related costs or expenses. 10. Force Majeure. Omron shall not be liable for any delay or failure in delivery resulting from causes beyond its control, including earthquakes, fires, floods, strikes or other labor disputes, shortage of labor or materials, accidents to machinery, acts of sabotage, riots, delay in or lack of transportation or the requirements of any government authority. 11. Shipping; Delivery. Unless otherwise expressly agreed in writing by Omron: a. Shipments shall be by a carrier selected by Omron; Omron will not drop ship except in “break down” situations. b. Such carrier shall act as the agent of Buyer and delivery to such carrier shall constitute delivery to Buyer; c. All sales and shipments of Products shall be FOB shipping point (unless otherwise stated in writing by Omron), at which point title and risk of loss shall pass from Omron to Buyer; provided that Omron shall retain a security interest in the Products until the full purchase price is paid; d. Delivery and shipping dates are estimates only; and e. Omron will package Products as it deems proper for protection against normal handling and extra charges apply to special conditions. 12. Claims. Any claim by Buyer against Omron for shortage or damage to the Products occurring before delivery to the carrier must be presented in writing to Omron within 30 days of receipt of shipment and include the original transportation bill signed by the carrier noting that the carrier received the Products from Omron in the condition claimed. 13. Warranties. (a) Exclusive Warranty. Omron’s exclusive warranty is that the Products will be free from defects in materials and workmanship for a period of twelve months from the date of sale by Omron (or such other period expressed in writing by Omron). Omron disclaims all other warranties, express or implied. (b) Limitations. OMRON MAKES NO WARRANTY OR REPRESENTATION, EXPRESS OR IMPLIED, ABOUT NON-INFRINGEMENT, MERCHANTABIL- 14. 15. 16. 17. 18. ITY OR FITNESS FOR A PARTICULAR PURPOSE OF THE PRODUCTS. BUYER ACKNOWLEDGES THAT IT ALONE HAS DETERMINED THAT THE PRODUCTS WILL SUITABLY MEET THE REQUIREMENTS OF THEIR INTENDED USE. Omron further disclaims all warranties and responsibility of any type for claims or expenses based on infringement by the Products or otherwise of any intellectual property right. (c) Buyer Remedy. Omron’s sole obligation hereunder shall be, at Omron’s election, to (i) replace (in the form originally shipped with Buyer responsible for labor charges for removal or replacement thereof) the non-complying Product, (ii) repair the non-complying Product, or (iii) repay or credit Buyer an amount equal to the purchase price of the non-complying Product; provided that in no event shall Omron be responsible for warranty, repair, indemnity or any other claims or expenses regarding the Products unless Omron’s analysis confirms that the Products were properly handled, stored, installed and maintained and not subject to contamination, abuse, misuse or inappropriate modification. Return of any Products by Buyer must be approved in writing by Omron before shipment. Omron Companies shall not be liable for the suitability or unsuitability or the results from the use of Products in combination with any electrical or electronic components, circuits, system assemblies or any other materials or substances or environments. Any advice, recommendations or information given orally or in writing, are not to be construed as an amendment or addition to the above warranty. See http://www.omron247.com or contact your Omron representative for published information. Limitation on Liability; Etc. OMRON COMPANIES SHALL NOT BE LIABLE FOR SPECIAL, INDIRECT, INCIDENTAL, OR CONSEQUENTIAL DAMAGES, LOSS OF PROFITS OR PRODUCTION OR COMMERCIAL LOSS IN ANY WAY CONNECTED WITH THE PRODUCTS, WHETHER SUCH CLAIM IS BASED IN CONTRACT, WARRANTY, NEGLIGENCE OR STRICT LIABILITY. Further, in no event shall liability of Omron Companies exceed the individual price of the Product on which liability is asserted. Indemnities. Buyer shall indemnify and hold harmless Omron Companies and their employees from and against all liabilities, losses, claims, costs and expenses (including attorney's fees and expenses) related to any claim, investigation, litigation or proceeding (whether or not Omron is a party) which arises or is alleged to arise from Buyer's acts or omissions under these Terms or in any way with respect to the Products. Without limiting the foregoing, Buyer (at its own expense) shall indemnify and hold harmless Omron and defend or settle any action brought against such Companies to the extent based on a claim that any Product made to Buyer specifications infringed intellectual property rights of another party. Property; Confidentiality. Any intellectual property in the Products is the exclusive property of Omron Companies and Buyer shall not attempt to duplicate it in any way without the written permission of Omron. Notwithstanding any charges to Buyer for engineering or tooling, all engineering and tooling shall remain the exclusive property of Omron. All information and materials supplied by Omron to Buyer relating to the Products are confidential and proprietary, and Buyer shall limit distribution thereof to its trusted employees and strictly prevent disclosure to any third party. Export Controls. Buyer shall comply with all applicable laws, regulations and licenses regarding (i) export of products or information; (iii) sale of products to “forbidden” or other proscribed persons; and (ii) disclosure to non-citizens of regulated technology or information. Miscellaneous. (a) Waiver. No failure or delay by Omron in exercising any right and no course of dealing between Buyer and Omron shall operate as a waiver of rights by Omron. (b) Assignment. Buyer may not assign its rights hereunder without Omron's written consent. (c) Law. These Terms are governed by the law of the jurisdiction of the home office of the Omron company from which Buyer is purchasing the Products (without regard to conflict of law principles). (d) Amendment. These Terms constitute the entire agreement between Buyer and Omron relating to the Products, and no provision may be changed or waived unless in writing signed by the parties. (e) Severability. If any provision hereof is rendered ineffective or invalid, such provision shall not invalidate any other provision. (f) Setoff. Buyer shall have no right to set off any amounts against the amount owing in respect of this invoice. (g) Definitions. As used herein, “including” means “including without limitation”; and “Omron Companies” (or similar words) mean Omron Corporation and any direct or indirect subsidiary or affiliate thereof. Certain Precautions on Specifications and Use 1. Suitability of Use. Omron Companies shall not be responsible for conformity with any standards, codes or regulations which apply to the combination of the Product in the Buyer’s application or use of the Product. At Buyer’s request, Omron will provide applicable third party certification documents identifying ratings and limitations of use which apply to the Product. This information by itself is not sufficient for a complete determination of the suitability of the Product in combination with the end product, machine, system, or other application or use. Buyer shall be solely responsible for determining appropriateness of the particular Product with respect to Buyer’s application, product or system. Buyer shall take application responsibility in all cases but the following is a non-exhaustive list of applications for which particular attention must be given: (i) Outdoor use, uses involving potential chemical contamination or electrical interference, or conditions or uses not described in this document. (ii) Use in consumer products or any use in significant quantities. (iii) Energy control systems, combustion systems, railroad systems, aviation systems, medical equipment, amusement machines, vehicles, safety equipment, and installations subject to separate industry or government regulations. (iv) Systems, machines and equipment that could present a risk to life or property. Please know and observe all prohibitions of use applicable to this Product. NEVER USE THE PRODUCT FOR AN APPLICATION INVOLVING SERIOUS RISK TO LIFE OR PROPERTY OR IN LARGE QUANTITIES WITHOUT ENSURING THAT THE SYSTEM AS A WHOLE HAS BEEN DESIGNED TO 2. 3. 4. 5. ADDRESS THE RISKS, AND THAT THE OMRON’S PRODUCT IS PROPERLY RATED AND INSTALLED FOR THE INTENDED USE WITHIN THE OVERALL EQUIPMENT OR SYSTEM. Programmable Products. Omron Companies shall not be responsible for the user’s programming of a programmable Product, or any consequence thereof. Performance Data. Data presented in Omron Company websites, catalogs and other materials is provided as a guide for the user in determining suitability and does not constitute a warranty. It may represent the result of Omron’s test conditions, and the user must correlate it to actual application requirements. Actual performance is subject to the Omron’s Warranty and Limitations of Liability. Change in Specifications. Product specifications and accessories may be changed at any time based on improvements and other reasons. It is our practice to change part numbers when published ratings or features are changed, or when significant construction changes are made. However, some specifications of the Product may be changed without any notice. When in doubt, special part numbers may be assigned to fix or establish key specifications for your application. Please consult with your Omron’s representative at any time to confirm actual specifications of purchased Product. Errors and Omissions. Information presented by Omron Companies has been checked and is believed to be accurate; however, no responsibility is assumed for clerical, typographical or proofreading errors or omissions. OMRON AUTOMATION AND SAFETY • THE AMERICAS HEADQUARTERS • Chicago, IL USA • 847.843.7900 • 800.556.6766 • www.omron247.com OMRON CANADA, INC. • HEAD OFFICE Toronto, ON, Canada • 416.286.6465 • 866.986.6766 • www.omron247.com OMRON ARGENTINA • SALES OFFICE Cono Sur • 54.11.4783.5300 OMRON ELECTRONICS DE MEXICO • HEAD OFFICE México DF • 52.55.59.01.43.00 • 01-800-226-6766 • mela@omron.com OMRON CHILE • SALES OFFICE Santiago • 56.9.9917.3920 OMRON ELECTRONICS DE MEXICO • SALES OFFICE Apodaca, N.L. • 52.81.11.56.99.20 • 01-800-226-6766 • mela@omron.com OTHER OMRON LATIN AMERICA SALES 54.11.4783.5300 OMRON ELETRÔNICA DO BRASIL LTDA • HEAD OFFICE São Paulo, SP, Brasil • 55.11.2101.6300 • www.omron.com.br OMRON EUROPE B.V. • Wegalaan 67-69, NL-2132 JD, Hoofddorp, The Netherlands. • +31 (0) 23 568 13 00 • www.industrial.omron.eu Authorized Distributor: Automation Control Systems • Machine Automation Controllers (MAC) • Programmable Controllers (PLC) • Operator interfaces (HMI) • Distributed I/O • Software Drives & Motion Controls • Servo & AC Drives • Motion Controllers & Encoders Temperature & Process Controllers • Single and Multi-loop Controllers Sensors & Vision • Proximity Sensors • Photoelectric Sensors • Fiber-Optic Sensors • Amplified Photomicrosensors • Measurement Sensors • Ultrasonic Sensors • Vision Sensors Industrial Components • RFID/Code Readers • Relays • Pushbuttons & Indicators • Limit and Basic Switches • Timers • Counters • Metering Devices • Power Supplies Safety • Laser Scanners • Safety Mats • Edges and Bumpers • Programmable Safety Controllers • Light Curtains • Safety Relays • Safety Interlock Switches $&@@ 0/14 Note: Specifications are subject to change. Printed on recycled paper. © 2014 Omron Electronics LLC Printed in U.S.A.
WLG12-TC-N 价格&库存

很抱歉,暂时无法提供与“WLG12-TC-N”相匹配的价格&库存,您可以联系我们找货

免费人工找货