Two-circuit Limit Switch/Long-life Two-circuit Limit Switch
WL-N/WLM-N
Select the Best Two-circuit Switch for the
Operating Environment and Application
from a Wide Range of Models
• A wide selection of models is available, including
general-purpose, environment-resistant, and spatterprevention switches.
• Standard-feature gold-clad crossbar contacts provide
high reliability.
• Applicable to either standard loads or microloads.
• Switches with lever actuators provide 90° overtravel,
one-side operation, and four-direction head mounting.
• Approved standards: EN/IEC, UL, cUL, and CCC.
Contact your OMRON representative for information on
approved models.
Be sure to read Safety Precautions on page 44 to 48 and
Safety Precautions for All Limit Switches.
Features
Standard Switches
Features Common to All Switches
Many Variations in Standard Limit Switches
DPDB Operation
A Wide Range of Models
The double-pole, double-break structure ensures circuit braking.
The series includes includes many different actuators that you select
to match the workpiece shape and motion, and a wide range of Switch
variations, such as models with operation indicators for easier
working and maintenance and models with different types of
connectors.
Za
(NO)14
13(NO)
(NC)12
11(NC)
11
13
12
14
Load
Load
Environment-resistant Switches
Select from Six Types of Environment Resistance
The series includes airtight switches, hermetic switches, heatresistant switches, low-temperature switches, corrosion-proof
switches, and weather-proof switches. You can select the model
based on the onsite environment.
Spatter-prevention Switches
Excellent Performance on Arc Welding Lines or Sites with
Spattering Cutting Powder
Ideal for Welding Sites
These Switches use stainless steel or resin to prevent the adhesion
of spatter.
They can be used to reduce problems caused by zinc power
generated during welding.
Long-life Switches
Mechanical Endurance of 30 Million Operations
Long-life Models for High-frequency Applications
A mechanical durability of 30 million operations minimum is provided.
The head features a double-seal structure with a head cap and oil
seal.
Degree of Protection; IP67
Approved Standards to Aid Export Machines
The Switches are certified for EN/IEC, UL, cUL, and CCC making
them ideal for export machines.
Applicable to Either Standard Loads or Microloads
Standard-feature gold-clad contacts provide high reliability.
The use of a high-contact-pressure crossbar structure also increases
reliability.
Easy to Work With
Downsizing of the built-in switch has increased the space to house the
wiring.
The insulating paper that was often in the way when wiring has been
eliminated.
Nickle-plated steel screws are used for the terminal screws.
The screws adhere to magnetized screwdrivers to prevent dropping and
loosing them.
Models with Connectors to Reduce Wiring
A neon lamp or LED indicates the operating status.
The 3D structure of the lamp cover disperses light so you can check
the operating status from the side.
1
WL-N/WLM-N
Product Configuration
• Basic Switches
WLC@-N
• High-sensitivity Switches
WLG@-N
• High-precision Switches
WLGCA2-N
• Protective Switches
WLCA32-@-N
• Indicator-equipped Switches:
Neon lamps
WL@-LE-N
• Indicator-equipped Switches:
Light emitting diodes (LED)
WL@-LD-N
• Direct-wired Switches
WL-@LDK@-N
• Pre-wired Switches
WL@-@LD-M1@-N
WL@-@LD-AGJ-N
WL@-@LD-DGJ-N
WL@-@LD-DK1EJ-N
• Airtight Switches
WL@-55-N
• Hermetic Switches
WL@-139-N
WL@-140-N
WL@-141-N
WL@-145-N
WL@-RP40-N
WL@-RP60-N
• Heat-resistant Switches
WL@-TH-N
• Low-temperature Switches
WL@-TC-N
• Corrosion-proof Switches
WL@-RP-N
• Weather-proof Switches
WL@-P1-N
• Basic Switches
WLC@-@S-N
• High-sensitivity Switches
WLG@-@S-N
• High-precision Switches
WLGCA2-@S-N
• Basic Switches
WLMCA2-@-N
• High-sensitivity Switches
WLMG2-@-N
• High-precision Switches
WLMGCA2-@-N
Standard
General-purpose
Operation indicators
Sensor I/O connectors
Environment-resistant
Spatter-prevention
Long-life
2
WL-N/WLM-N
Environment-resistant Switches
Item
Type
Airtight seal
Model
Environment-resistant
Application
Environment-resistant construction
Uses an airtight built-in switch.
WL@-55-N
Note: Use the SC Connector for the conduit opening.
WL@-139-N
For use in locations subWL@-140-N ject to cutting oil or water.
WL@-141-N
Hermetic seal
(Molded terminals/ WL@-145-N
Anti-coolant)
WL@-RP40-N
Applicable models
All models except the lowtemperature and heat-resistant models
Note: Models can be produced
using standard
actuators.
All models except the lowtemperature and heat-resistant models
Refer to page 29 for information on the environment-resistant construction of Switches with Hermetic Seals.
WL@-RP60-N
Note: Models can be produced
using standard
actuators. Only the
WLCA2-N, WLGCA2-N,
or WLG2-N can be
produced for the WL@141-N and WL@-145-N.
Low-temperature
Can be used at a temperature of –40°C (operating
WL@-TC-N temperature range: –40 to
40°C), but cannot withstand icing.
Heat-resistant
Can be used in temperatures of 120°C (operating
WL@-TH-N
temperature range: 5 to
120°C).
• Fluorine rubber is used for rubber parts such as
the O-ring, gasket, etc.
All models except airtight
seal, hermetic seal, heatresistant, corrosion-proof,
and indicator-equipped, nylon roller (WLCA2-26N-N),
seal roller models, and resin rod (WLNJ-2-N) models
For use in locations subWL@-RP-N ject to corrosive gases and
chemicals.
• Diecast parts, such as the switch box, are made
of corrosion-proof aluminum.
• Rubber sealing parts are made of fluorine
rubber, which aids in resisting oils and
chemicals.
• Exposed nuts and screws (except the actuator
section) are made of stainless steel.
• Moving and rotary parts such as rollers are
made of sintered stainless steel or stainless
steel.
• The head, box, and cover are yellow.
All models except fork lever
lock (WLCA32-41 to -44N), low-temperature, heatresistant, and indicatorequipped models
For use in parking lots and
other outdoor locations.
• Rubber parts are made from epichlorhydrin
rubber, which has a high-tolerance to changes in
temperature.
• Rollers are made of stainless steel to improve
corrosion resistance.
• Exposed nuts and screws are made of stainless
steel.
Only basic (WLCA2-N/
CA12-N/CL-N), and highsensitivity overtravel
(WLG2-N/G12-N/GL-N)
models (excluding heat-resistant models).
This does not apply to lowtemperature or heat-resistant, or indicatorequipped switches.
Corrosion-proof
Weather-proof
WL@-P1-N
• Uses a general-purpose built-in switch.
• Epichlorhydrin rubber is used for rubber parts
such as the O-ring, gasket, etc.
All models except airtight
seal, hermetic seal, heatresistant, corrosion-proof,
and indicator-equipped
models
3
WL-N/WLM-N
Selection Guide
With the WL-N Series, OMRON will combine the switch, actuator, and wiring method required to build the ideal switch for
your application.
The WL-N Series consists of four basic types: general-purpose, environment-resistant, spatter-protection, and long-life switches. WLCA2-N Switches can be used for the most common applications.
According to Operating Environment
Ambient operating temperature
Environment
−10°C
+80°C
Models
WL@-N
Normal
WLM@-N
Water-resistant to IP67.
High-temperature
WL@-TH-N
Heat-resistant
Switches *1
WL@-TC-N
Low-temperature
Switches *1
To increase heat resistance, the rubber material (fluorine rubber)
and the plunger material (PEEK) have been changed.
−40°C
+40°C
Low-temperature
To increase resistance to cold, epichlorhydrin rubber and other
measures are used.
Chemicals and oil
Water drops and mist
Constant water
drops and mist
Rubber parts are made from epichlorhydrin rubber, which has a
high-tolerance to changes in temperature.
WL@-P1-N
Stainless steel is used for the screws.
Rollers are made of stainless steel to provide superior corrosion
resistance.
Corrosion-proof specifications have been used for the housing,
fluorine rubber has been used for rubber parts, and stainless
WL@-RP-N
steel has been used for screws and nuts (except for the actuator)
to increase resistance to oils, chemicals, and weather.
Weather-proof
Switches *1
Corrosion-proof
Switches *1
Uses an airtight built-in switch.
WL@-55-N
Cables are attached. Uses a general-purpose built-in switch.
The cover screws, case cover, and conduit opening are molded
from epoxy resin to increase the seal.
(The cover cannot be removed.)
WL@-139-N
Hermetic, Molded-terminal
Switches *1, *2
Cables are attached. Uses an airtight built-in switch.
The case cover and conduit opening are molded from epoxy
resin to increase the seal. (The cover cannot be removed.)
The SC connector can be removed, so it is possible to use
flexible conduit for the cable.
Cables are attached. Uses an airtight built-in switch.
The cover screws, case cover, and conduit opening are molded
from epoxy resin to increase the seal.
(The cover cannot be removed.)
Airtight Switches *1
WL@-RP40-N
Hermetic, Molded-terminal
Switches *1, *2
WL@-140-N
Hermetic, Molded-terminal
Switches *1, *2
Constant water
drops or splattering
cutting powder
Cables are attached. Uses an airtight built-in switch.
The cover screws, case cover, and conduit opening are molded
from epoxy resin to increase the seal.
(The cover cannot be removed.)
Double seal against oil including head cap countermeasure for
cutting chips and an oil seal.
-141: The Head section is molded from epoxy resin;
Head direction cannot be changed.
-145: The Head section is molded from epoxy resin;
Head can be in any of 4 directions.
Coolant
Cables are attached. Uses an airtight built-in switch.
The cover screws, case cover, conduit opening, and head screws
WL@-RP60-N
are molded from epoxy resin to increase the seal.
Hermetic, Molded-terminal
(The cover and head cannot be removed.)
Switches *1, *2
Rubber parts are made from fluorine rubber to increase
resistance to coolant.
Spattering from
welding
To prevent spatter during welding, a heat-resistant resin is used
for the indicator cover and screws and rollers are all made from
stainless steel.
WL@-141-N, -145-N
Hermetic, Molded-terminal
Switches *1, *2
(Only the WLCA2-N, WLG2-N, and
WLGCA2-N, can be produced.)
WL@-S-N
*1. Not all functions can be combined with environment-resistant switches. Refer to the applicable models on the previous page.
*2. Refer to page 29 for information on the construction of Hermetic Switches.
4
General-purpose
Switches
Long-life Switches
+120°C
+5°C
Outdoors
Operating environment
Key specifications
Spatter-prevention
Switches
WL-N/WLM-N
According to Application Conditions
Conditions
Durability
Load
Switching standard
loads
Key specifications
10 A at 125, 250, or 500 VAC
0.8 A at 125 VDC
0.4 A at 250 VDC
Models
Entire WL@-@-N Series
Applicable to either standard loads or microloads.
Switching
microloads
0.1 A at 125 VAC, resistive load
0.1 A at 30 VDC, resistive load
Normal durability
Mechanical: 15 million operation min.
(10 million operation min. for high-sensitivity
models or flexible rod models)
WL@-N
WL@-S-N
General-purpose Switches
Spatter-prevention Switches
Long-life
Mechanical: 30 million operation min.
WLM@-N
Long-life Switches
According to Ease of Installation and Maintenance
Operation indicator
Conditions
Daily inspections
and maintenance
checks
Wiring specification
Screw tightening
and installation
Key specifications
Neon lamp
125 to 250 VAC
Switching light-ON between operating/not
operating. (Switching is not possible for
Switches with Molded Terminals.)
WL@-LE-N
General-purpose, Indicator-equipped (Neon Lamp) Switches
WL@-LES-N
Spatter-prevention, Indicator-equipped (Neon Lamp) Switches
LED
10 to 115 VAC/DC
Switching light-ON between operating/not
operating. (Switching not possible for models
with molded terminals.)
WL@-LD-N
General-purpose, Indicator-equipped (LED) Switches
WL@-LDS-N
Spatter-prevention, Indicator-equipped (LED) Switches
Screw terminals. No ground terminal.
Conduit size: G1/2
WL@-N
WLM@-N
General-purpose Switches
Long-life Switches
Screw terminals. Ground terminal.
Conduit size: 4 sizes
WL@-N
General-purpose Switches
Direct-wired connector, 2-conductor.
Greatly reduces wiring work.
WL@-@LDK13@-N
General-purpose, Direct-wired Connector Switches
WLM@-LDK13@-N
Long-life, Direct-wired Connector Switches
Direct-wired connector, 4-conductor.
Greatly reduces wiring work.
WL@-@LDK43@-N
General-purpose, Direct-wired Connector Switches
WLM@-LDK43@-N
Long-life, Direct-wired Connector Switches
Pre-wired connector, 2-conductor.
Greatly reduces wiring work.
Smartclick connectors for even easier
maintenance.
WL@-@LD-M1@J-N
General-purpose, Pre-wired Connector Switches
WL@-@S-M1@J-1-N
Spatter-prevention, Pre-wired Connector Switches
WLM@-LD-M1@J-N
Long-life, Pre-wired Connector Switches
Pre-wired connector, 4-conductor.
Greatly reduces wiring work.
Smartclick connectors for even easier
maintenance.
WL@-@LD-@GJ-N
General-purpose, Pre-wired Connector Switches
WL@-@S-@GJS-N
Spatter-prevention, Pre-wired Connector Switches
WLM@-LD-@GJ-N
Long-life, Pre-wired Connector Switches
One-touch
connector
attachment
Connector
attachment in
control and relay
boxes
Models
5
WL-N/WLM-N
According to Form of Operation
Detection object
General
Key specifications
TT (total travel)
PT (pretravel)
15°
Operation angles
90°
Models
25°
20°
90°
Passing dogs
WLCA2-N
WLCA2-2-N
WLCA2-2N-N
10°
Passing dogs,
high sensitivity
90°
90°
90°
90°
5°
High precision
R38
Dogs and
workpieces
(Mounts in any of
4 directions)
R50
R63
WLCA2-N
WLCA2-2-N
WLCA2-2N-N
WLCA2-@S-N
WLMCA2-N
General-purpose Switches
General-purpose Switches
General-purpose Switches
Spatter-prevention Switches
Long-life Switches
WLG2-N
WLG2-@S-N
WLMG2-N
General-purpose Switches
Spatter-prevention Switches
Long-life Switches
WLGCA2-N
General-purpose Switches
WLGCA2-@S-N Spatter-prevention Switches
WLMGCA2-N
Long-life Switches
●
Short lever
WL@2-N
One-Horizontal operation possible. WL@2-@S-N
● Head mounts in any of 4 directions. WLM@2-N
Roller Lever Actuators
Roller Lever Actuators
Roller Lever Actuators
●
Medium lever
One-side operation possible.
WL@2-7-N
● Head mounts in any of 4 directions.
Roller Lever Actuators
Long lever
WL@2-8-N
One-side operation possible.
● Head mounts in any of 4 directions.
Roller Lever Actuators
●
●
●
●
R25 to 89
Adjustable between
dog and lever
One-Horizontal operation possible.
WL@12-N
Head mounts in any of 4 directions.
Adjustable Roller Lever Actuators
One-Horizontal operation possible.
WLCL-N
Head mounts in any of 4 directions.
Adjustable Rod Lever Actuators
One-side operation possible.
WLCAL4-N
Head mounts in any of 4 directions.
Adjustable Rod Lever Actuator
●
One-side operation possible.
WLCAL5-N
Head mounts in any of 4 directions.
Rod Spring Lever Actuator
●
Head mounts in any of 4 directions. WLCA32-41-N
Fork Lever Lock Actuator
●
Head mounts in any of 4 directions. WLCA32-42-N
Fork Lever Lock Actuator
●
Head mounts in any of 4 directions. WLCA32-43-N
Fork Lever Lock Actuator
●
Head mounts in any of 4 directions. WLCA32-44-N
Fork Lever Lock Actuator
●
Equipped with sealing boot.
Sealed Top Plunger Actuator
●
Head mounts in any of 4 directions. WLSD-N
Horizontal Plunger Actuator
●
Equipped with sealing boot.
Sealed Top-ball Plunger Actuator
●
Head mounts in any of 4 directions. WLSD3-N
●
Equipped with sealing boot.
●
Head mounts in any of 4 directions. WLSD2-N
●
●
25 to 140
●
●
Dogs or workpieces
with large
deflection
350 to 380
●
Actuators
427.5
Round-trip
operation of
passing dogs
Cams or
workpieces with
vertical movement
6
●
●
WLD18-N
WLD38-N
WLD28-N
Horizontal-ball Plunger Actuator
Sealed Top-roller Plunger Actuator
Horizontal-roller Plunger Actuator
WL-N/WLM-N
Application Examples
Detection of Passing Pallets on Production
Lines
Detection of Work Table Origins (X, Y, and Z)
on Machine Tools
Detection of Forward and Reverse Movement
of Hydraulic Cylinders on Molding Machines
Detection of Arm Movement on Welding
Robots
Detection of Car Pallet Positions in Parking
Towers
Detection of Vertical Limits on Conveyor
Systems
7
WL-N/WLM-N
Model Number Structure
Model Number Legend (Not all combinations are possible. Contact your OMRON representative for details.)
General-purpose Switches
WL@ - @ @ @ @ -N
(1)
(2) (3) (4) (5)
(1) Actuator and Property Specifications
Code
(2) Built-in Switch Type
Pretravel (PT)
Code
CA2
Roller lever: R38 mm
Blank
CA2-7
Roller lever: R50 mm
55
CA2-8
Roller lever: R63 mm
CA12
Adjustable roller lever: R25 to 89 mm
CL
Adjustable rod lever: 25 to 140 mm
CAL4
Adjustable rod lever: 350 to 380 mm
CAL5
Rod spring lever
CA2-2
Roller lever: R38 mm
CA12-2
Adjustable roller lever: R25 to 89 mm
CL-2
15±5°
CA2-2N
Roller lever: R38 mm
Adjustable roller lever: R25 to 89 mm
Airtight built-in switch
(3) Conduit Size, Ground Terminal Specifications
Specifications
25±5°
Blank
G1/2
G1
G1/2
G
Pg13.5
Y
M20
TS
MAX 20°
Conduit Size
Ground terminal
None
Provided *
1/2-14NPT
* Models with ground terminals are certified for EN/IEC (CE Marking).
Adjustable rod lever: 25 to 140 mm
G2
Roller lever, high sensitivity: R38 mm
G12
Adjustable roller lever, high sensitivity:
R25 to 89 mm
GL
Adjustable rod lever, high sensitivity:
25 to 140 mm
GCA2
Roller lever, high precision: R38 mm
CA32-41
Fork lever lock
CA32-42
Fork lever lock
CA32-43
(4) Indicator Type
10° +2°
−1°
5° +2°0°
50±5°
Code
Blank
LE
Neon lamp: 125 to 250 VAC
LED (10 to 115 VAC/DC)
(5) Lever Type
Fork lever lock
Code
Sealed top plunger
Blank
D28
Sealed top-roller plunger
D38
Sealed top-ball plunger
SD
Horizontal plunger
SD2
Horizontal-roller plunger
SD3
Horizontal-ball plunger
NJ
Flexible rod: Coil spring
Flexible rod: Coil spring, multi-wire
NJ-2
Flexible rod: Resin rod
NJ-S2
Flexible rod: Steel wire
1.7 mm
2.8 mm
20±10 mm
40±20 mm
Specifications
No indicator
LD
D18
NJ-30
Specification
Standard built-in switch
Code
Adjustable rod lever: 25 to 140 mm
CA12-2N
CL-2N
8
Lever
A
Specifications
Standard lever (Allen-head bolt)
Double nut lever
WL-N/WLM-N
Model Number Legend (Not all combinations are possible. Contact your OMRON representative for details.)
General-purpose Switches
Sensor I/O Connector Switches
WL@ - @ L D @ -N
(1)
(2) (3) (4)
(1) Actuator and Property Specifications
Code
CA2
Lever
(2) Built-in Switch Type
Pretravel (PT)
Code
Roller lever: R38 mm
15±5°
Blank
G2
Roller lever, high sensitivity: R38 mm
10° +2°
−1°
55
GCA2
Roller lever, high precision: R38 mm
5° +2°0°
Sealed top-roller plunger
1.7 mm
D28
Specification
Standard built-in switch
Airtight built-in switch
(3) Indicator Type
Code
LD
Specifications
LED (10 to 115 VAC/DC)
(4) Connector Type
Code
Specification
Shape
K13A
K13
K43A
Voltage used *1
AC
Direct-wired connector Threaded (M12)
Wiring locations
NO only
Connector pin No. *2
NO: 3 4
DC
NO only
NO: 3 4
AC
NC+NO
NC: 1 2 , NO: 3 4
NC: 1 2 , NO: 3 4
K43
DC
NC+NO
-M1J
DC
NO only
NO: 3 4
-M1GJ
DC
NO only
NO: 1 4
DC
NC only
NC: 2 3
AC
NC+NO
NC: 1 2 , NO: 3 4
DC
NC+NO
NC: 1 2 , NO: 3 4
DC
NO only
NC: 2 , NO: 3 4
DC
NO only
NO: 3 4
DC
NO only
NO: 1 4
DC
NC only
NC: 2 3
-DTGJ
DC
NC+NO
NC: 1 2 , NO: 3 4
-DTK1EJ
DC
NO only
NC: 2 , NO: 3 4
-M1JB
Threaded (M12)
-AGJ
-DGJ
-DK1EJ
Pre-wired connector *3
-M1TJ
-M1TGJ
-M1TJB
Smartclick
*1. DC models are certified for EN/IEC (CE Marking).
*2. Refer to Contact Forms on page 16 for details on connector pin numbers.
*3. The standard cable length is 0.3 m. Contact your OMRON representative for information on other cable lengths.
9
WL-N/WLM-N
Model Number Legend (Not all combinations are possible. Contact your OMRON representative for details.)
Environment-resistant Switches
WL@ - @ @ @ @ @ @ @ @ -N
(1)
(2) (3) (4) (5) (6) (7) (8) (9)
(1) Actuator and Property Specifications
Code
Lever
CA2
Roller lever: R38 mm
CA2-7
Roller lever: R50 mm
CA2-8
Roller lever: R63 mm
CA12
Adjustable roller lever: R25 to 89 mm
CL
Adjustable rod lever: 350 to 380 mm
Rod spring lever
CA2-2
Roller lever: R38 mm
CA12-2
Adjustable roller lever: R25 to 89 mm
25±5°
Roller lever: R38 mm
CA12-2N
Adjustable roller lever: R25 to 89 mm
Roller lever, high sensitivity: R38 mm
G12
Adjustable roller lever, high sensitivity: R25
to 89 mm
GL
Adjustable rod lever, high sensitivity: 25 to
140 mm
Roller lever, high precision: R38 mm
CA32-41
Fork lever lock
CA32-42
Fork lever lock
CA32-43
Fork lever lock
Sealed top plunger
D28
Sealed top-roller plunger
D38
Sealed top-ball plunger
SD
Horizontal plunger
Horizontal-roller plunger
SD3
Horizontal-ball plunger
NJ
Flexible rod: Coil spring
NJ-30
Flexible rod: Coil spring, multi-wire
NJ-2
Flexible rod: Resin rod
NJ-S2
Flexible rod: Steel wire
Code
5°
2.8 mm
20±10 mm
40±20 mm
Specifications
Blank
RP60
Airtight built-in switch. Cables are attached.
Molded conduit opening, cover, cover screws, and head
screws. (The cover cannot be removed and the head direction
cannot be changed.)
Fluorine rubber is used for all rubber parts.
Conduit Size
Blank
G1/2
G1
G1/2
G
Pg13.5
Y
M20
TS
Ground terminal
None
Provided *2
1/2-14NPT
*2. Models with ground terminals are certified for EN/IEC (CE
Marking).
(7) Indicator Type
Blank
Weather-proof
Specifications
Specifications
No indicator
LE
Neon lamp: 125 to 250 VAC
LD
LED (10 to 115 VAC/DC)
*3. Cannot be combined with Corrosion-proof (RP), Weather-proof
(P1), Heat-resistant (TC), or Low-temperature (TC) Switches.
Standard built-in switch
(8) Indicator Wiring Specification
Airtight built-in switch
Specifications
Standard: −10°C to +80°C
TH
Heat-resistant: +5°C to +120°C *1
TC
Low-temperature: −40°C to +40°C *1
*1. Cannot be combined with Corrosion-proof (RP) or Weather-proof
(P1) Switches.
Code
Specifications
2
NC connection: Light-ON when operating
3
NO connection: Light-ON when not operating
*4. Always include the indicator wiring specification if you specify a
(5) hermetic structure and an (7) indicator.
(9) Lever Type
Code
Blank
A
10
Specifications
Code
Code
Corrosion-proof
(4) Temperature Specifications
Code
RP40
Airtight built-in switch. Cable is attached.
Molded conduit opening and cover. (The cover cannot be removed.)
SC Connector can be removed, so it is possible to use flexible
conduits for the cable.
Standard
Code
55
145
Airtight built-in switch. Cable is attached.
Molded conduit opening, cover, and cover screws. (The cover
cannot be removed. The head can be mounted in any of 4 directions.)
Double seal against oil including head cap countermeasure for
cutting chips and an oil seal.
1.7 mm
(3) Built-in Switch Type
Blank
141
Airtight built-in switch. Cable is attached.
Molded conduit opening, cover, head, cover screws, and head
screws. (The cover cannot be removed and the head direction
cannot be changed.)
Double seal against oil including head cap countermeasure for
cutting chips and an oil seal.
+2°
0°
(2) Environment-resistant Model Specifications
P1
Airtight built-in switch. Cable is attached.
Molded conduit opening, cover, and cover screws. (The cover
cannot be removed.)
(6) Conduit Size, Ground Terminal Specifications
SD2
RP
140
10° +2°
−1°
55°
D18
Blank
Standard built-in switch. Cable is attached.
Molded conduit opening and cover. (The cover cannot be removed.)
MAX 20°
Adjustable rod lever: 25 to 140 mm
G2
Specifications
No cable molding.
139
Adjustable rod lever: 25 to 140 mm
CA2-2N
GCA2
Code
15±5°
Adjustable rod lever: 25 to 140 mm
CAL5
CL-2N
Pretravel (PT)
Blank
CAL4
CL-2
(5) Hermetic Specification
Specifications
Standard lever (Allen-head bolt)
Double nut lever
WL-N/WLM-N
Model Number Legend (Not all combinations are possible. Contact your OMRON representative for details.)
Spatter-prevention Switches
WL@ - @ @ S@ -N
(1)
(2) (3)
(4)
(1) Actuator and Property Specifications
Code
CA2
Lever
Pretravel (PT)
Roller lever: R38 mm
15±5°
G2
Roller lever, high sensitivity: R38 mm
10° +2°
−1°
GCA2
Roller lever, high precision: R38 mm
5° +2°0°
Sealed top-roller plunger
1.7 mm
D28
(2) Built-in Switch Type
Code
Blank
55
Specifications
Standard built-in switch
Airtight built-in switch
(3) Indicator Type
Code
Specifications
LE
Neon lamp: 125 to 250 VAC *1
LD
LED (10 to 115 VAC/DC)
*1. Cannot be combined with a Switch with a Connector.
(4) Connector Type
Specifications
Code
Blank
Shape
No connector
---DC
-M1J-1
-M1GJ-1
-DGJS
-DTGJS
Pre-wired Connector *4
Threaded (M12)
Smartclick
Voltage *2
Wiring locations
----
---NO only
Connector pin No. *3
---NO: 3 4
DC
NO only
NO: 1 4
DC
NC+NO
NC: 1 2 , NO: 3 4
DC
NC+NO
NC: 1 2 , NO: 3 4
*2. DC models are certified for EN/IEC (CE Marking).
*3. Refer to Contact Forms on page 16 for details on connector pin numbers.
*4. The standard cable length is 0.3 m. Contact your OMRON representative for information on other cable lengths.
11
WL-N/WLM-N
Model Number Legend (Not all combinations are possible. Contact your OMRON representative for details.)
Long-life Switches
WLM@ - LD @ -N
(1)
(2) (3)
(1) Actuator and Property Specifications
Code
CA2
Lever
Pretravel (PT)
Roller lever: R38 mm
15±5°
G2
Roller lever, high sensitivity: R38 mm
10° +2°
−1°
GCA2
Roller lever, high precision: R38 mm
5° +2°0°
(2) Indicator Type
Code
LD
Specifications
LED (10 to 115 VAC/DC)
(3) Connector Type
Specifications
Code
Blank
Shape
Screw terminals: G1/2 conduit
----
K13A
AC
Voltage
Wiring locations
----
---NO only
Connector pin No.
---NO: 3 4
DC
NO only
NO: 3 4
AC
NC+NO
NC: 1 2 , NO: 3 4
K43
DC
NC+NO
NC: 1 2 , NO: 3 4
-M1J
DC
NO only
NO: 3 4
AC
NC+NO
NC: 1 2 , NO: 3 4
DC
NC+NO
NC: 1 2 , NO: 3 4
DC
NO only
NO: 3 4
AC
NC+NO
NC: 1 2 , NO: 3 4
DC
NC+NO
NC: 1 2 , NO: 3 4
K13
K43A
Direct-wired connector
Threaded (M12)
-AGJ
-DGJ
-M1TJ
-ATGJ
-DTGJ
Threaded (M12)
Pre-wired connector *1
Smartclick
*1. The standard cable length is 0.3 m. Contact your OMRON representative for information on other cable lengths.
12
WL-N/WLM-N
Ordering Information
General-purpose Switches
Standard Switches
Switches with Lever Actuators
Actuator
Roller lever R38
Item
Pretravel (PT)
Model
Roller lever: R50
Roller lever: R63
Model
Model
WLCA2-7-N
WLCA2-8-N
15±5°
WLCA2-N
25±5°
WLCA2-2-N
-----
-----
MAX20°
WLCA2-2N-N
-----
-----
High-sensitivity
10° +2°
-1°
WLG2-N
-----
-----
High-precision
5° +2°0°
WLGCA2-N
-----
-----
Basic
Actuator
Adjustable roller lever
Item
Basic
High-sensitivity
Pretravel (PT)
Model
Adjustable rod lever:
25 to 140mm
Model
Adjustable rod lever:
350 to 380mm
Model
WLCAL4-N
Rod spring lever
Model
15±5°
WLCA12-N
WLCL-N
WLCAL5-N
25±5°
WLCA12-2-N
WLCL-2-N
-----
MAX20°
WLCA12-2N-N
WLCL-2N-N
-----
-----
10° +2°
-1°
WLG12-N
WLGL-N
-----
-----
-----
Actuator
Fork lever lock
Item
Protective
Movement until
the lever reverses
Model
50±5°
Fork lever lock
Model
Fork lever lock
Model
WLCA32-41-N
WLCA32-42-N
WLCA32-43-N
Sealed top plunger
Sealed top-roller
plunger
Sealed top-ball
plunger
Fork lever lock
Model
WLCA32-44-N
Switches with Plunger Actuators
Actuator
Item
Basic
Pretravel (PT)
1.7 mm
Model
WLD18-N
Actuator
Horizontal plunger
Item
Basic
Pretravel (PT)
2.8 mm
Model
WLSD-N
Model
WLD28-N
Horizontal-roller
plunger
Model
WLSD2-N
Model
WLD38-N
Horizontal-ball
plunger
Model
WLSD3-N
Switches with Flexible Rod Actuators
Actuator
Item
Basic
Pretravel (PT)
20±10 mm
Actuator
Item
Basic
Pretravel (PT)
40±20 mm
Coil spring
(spring diameter: 6.5)
Model
WLNJ-N
Resin rod
(rod diameter: 8)
Model
WLNJ-2-N
Coil spring
(spring diameter: 4.8)
Model
WLNJ-30-N
Steel wire
(wire diameter: 1)
Model
WLNJ-S2-N
13
WL-N/WLM-N
General-purpose Switches
Operation Indicator Switches
Switches with Lever Actuators
Actuator
Roller lever: R38
Indicator
Item
Pretravel (PT)
Model
Model
WLCA2-LE-N
25±5°
WLCA2-2LE-N
-----
-----
MAX20°
WLCA2-2NLE-N
-----
-----
High-sensitivity
10° +2°
-1°
WLG2-LE-N
-----
-----
High-precision
5° +2°0°
WLGCA2-LE-N
-----
-----
15±5°
WLCA2-LD-N
25±5°
WLCA2-2LD-N
-----
-----
MAX20°
WLCA2-2NLD-N
-----
-----
High-sensitivity
10° +2°
-1°
WLG2-LD-N
-----
-----
High-precision
5° +2°0°
WLGCA2-LD-N
-----
-----
Basic
Basic
LED
Actuator
Adjustable roller lever:
Indicator
Item
Basic
High-sensitivity
LED
Model
Basic
High-sensitivity
Pretravel (PT)
Model
WLCA2-7LE-N
Roller lever: R63
15±5°
Neon lamp
Neon lamp
Roller lever: R50
WLCA2-7LD-N
Adjustable rod lever:
25 to 140mm
Model
WLCL-LE-N
WLCA2-8LE-N
WLCA2-8LD-N
Adjustable rod lever:
350 to 380mm
Model
WLCAL4-LE-N
WLCA12-LE-N
25±5°
WLCA12-2LE-N
WLCL-2LE-N
-----
-----
MAX20°
WLCA12-2NLE-N
WLCL-2NLE-N
-----
-----
10° +2°
-1°
WLG12-LE-N
WLGL-LE-N
-----
15±5°
WLCA12-LD-N
WLCL-LD-N
25±5°
WLCA12-2LD-N
WLCL-2LD-N
-----
-----
MAX20°
WLCA12-2NLD-N
WLCL-2NLD-N
-----
-----
10° +2°
-1°
WLG12-LD-N
WLGL-LD-N
-----
-----
Fork lever lock
Item
Movement until
the lever reverses
Fork lever lock
Model
Model
WLCA32-42LE-N
Neon lamp Basic
50±5°
WLCA32-41LE-N
LED
50±5°
WLCA32-41LD-N
Basic
WLCAL4-LD-N
-----
Fork lever lock
Model
WLCA32-43LE-N
WLCA32-43LD-N
Switches with Plunger Actuators
Actuator
Sealed top plunger
Indicator
Item
Pretravel (PT)
Model
Sealed top-roller
plunger
Model
Model
1.7 mm
WLD18-LE-N
WLD28-LE-N
WLD38-LE-N
LED
1.7 mm
WLD18-LD-N
WLD28-LD-N
WLD38-LD-N
Horizontal plunger
Horizontal-roller
plunger
Actuator
Indicator
Item
Pretravel (PT)
Model
Model
Horizontal-ball
plunger
Model
Neon lamp Basic
2.8 mm
WLSD-LE-N
WLSD2-LE-N
WLSD3-LE-N
LED
2.8 mm
WLSD-LD-N
WLSD2-LD-N
WLSD3-LD-N
Basic
Switches with Flexible Rod Actuators
Actuator
Indicator
Item
Pretravel (PT)
Coil spring
(spring diameter: 6.5)
Model
Coil spring
(spring diameter: 4.8)
Model
Neon lamp Basic
20±10 mm
WLNJ-LE-N
WLNJ-30LE-N
LED
20±10 mm
WLNJ-LD-N
WLNJ-30LD-N
Basic
Actuator
Indicator
14
Sealed top-ball
plunger
Neon lamp Basic
Basic
Item
Pretravel (PT)
Resin rod
(rod diameter: 8)
Model
Steel wire
(wire diameter: 1)
Model
Neon lamp Basic
40±20 mm
WLNJ-2LE-N
WLNJ-S2LE-N
LED
40±20 mm
WLNJ-2LD-N
WLNJ-S2LD-N
Basic
Model
15±5°
Actuator
Indicator
Rod spring lever
WLCAL5-LE-N
----WLCAL5-LD-N
WL-N/WLM-N
General-purpose Switches
Sensor I/O Connector Switches
Switches with Direct-wired Connectors
Actuator
Roller lever: R38
Item
Connector shape
Built-in switch type
Voltage
AC
General-purpose
Threaded (M12)
DC
Airtight
AC
Wiring
locations
Connector
pin No.
Basic
High-sensitivity
High-precision
Model
Model
Model
NO only
NO 3 4
WLCA2-LDK13A-N
-----
-----
NC + NO
NC 1 2
NO 3 4
WLCA2-LDK43A-N
-----
-----
NO only
NO 3 4
WLCA2-LDK13-N
NC + NO
NC 1 2
NO 3 4
NO only
NO 3 4
NC + NO
NC 1 2
NO 3 4
WLG2-LDK13-N
WLGCA2-LDK13-N
WLCA2-LDK43-N
WLG2-LDK43-N
WLGCA2-LDK43-N
WLCA2-55LDK13-N
WLG2-55LDK13-N
WLGCA2-55LDK13-N
WLCA2-55LDK43-N
WLG2-55LDK43-N
WLGCA2-55LDK43-N
Switches with Pre-wired Connectors
Actuator
Roller lever R38
Item
Connector shape
Built-in switch type
Voltage
Wiring
locations
NO only
WLCA2-LD-M1J-N
Model
High-precision
Model
WLG2-LD-M1J-N
WLGCA2-LD-M1J-N
WLGCA2-LD-M1GJ-N
WLCA2-LD-M1GJ-N
WLG2-LD-M1GJ-N
NC 2 3
WLCA2-LD-M1JB-N
WLG2-LD-M1JB-N
NC + NO
NC 1 2
NO 3 4
WLCA2-LD-DGJ-N
WLG2-LD-DGJ-N
NO only
NO 4 3
NC 2
WLCA2-LD-DK1EJ-N
WLG2-LD-DK1EJ-N
----WLGCA2-LD-DGJ-N
-----
NO 3 4
WLCA2-55LD-M1J-N
NO 1 4
WLCA2-55LD-M1GJ-N
WLG2-55LD-M1GJ-N
WLGCA2-55LD-M1GJ-N
NC only
NC 2 3
WLCA2-55LD-M1JB-N
WLG2-55LD-M1JB-N
WLGCA2-55LD-M1JB-N
NC + NO
NC 1 2
NO 3 4
WLCA2-55LD-DGJ-N
WLG2-55LD-DGJ-N
WLGCA2-55LD-DGJ-N
NO only
NO 4 3
NC 2
WLCA2-55LD-DK1EJ-N
WLG2-55LD-DK1EJ-N
-----
NO only
NO 3 4
-----
WLG2-LD-M1TJ-N
-----
NO only
NC 2 3
-----
WLG2-LD-M1TJB-N
-----
NO only
Airtight
General-purpose
Model
NO 3 4
High-sensitivity
NO 1 4
Threaded (M12)
Smartclick
Basic
NC only
General-purpose
DC
Connector
pin No.
-----
WLGCA2-55LD-M1J-N
Note: The standard cable length for a pre-wired connector is 0.3 m. Contact your OMRON representative for information on other cable lengths.
15
WL-N/WLM-N
Contact Forms
Screw Terminal Switches
Screw Terminal Switches
Indicator-equipped (Light-ON when Not Operating) Switches *1
Za
14 (NO)
Internal
circuits
13 (NO)
12 (NC)
Za
14 (NO)
11 (NC)
12 (NC)
13 (NO)
11 (NC)
Direct-wired Connectors/Pre-wired Connectors
Indicator-equipped (Light-ON when Not Operating) Switches *1
AC
DC
Internal
circuits
Internal
circuits
Za
NO NC
4
WL@-@K13A-N
WL@-@K43A-N
WL@-@-AGJ-N
4
Za
NC NO
3
1
2
NO NC
3
1 2 3 4 indicate the connector pin number.
NC NO
WL@-@K13-N
WL@-@-M1J-N
WL@-@-M1TJ-N
4
3
WL@-@-M1GJ-N
WL@-@-M1TGJ-N
4
1
WL@-@-M1JB-N
WL@-@-M1TJB-N
WL@-@K43-N
WL@-@DGJ-N
WL@-@DTGJ-N
4
3
2
1
2
3
1 2 3 4 indicate the connector pin number.
Connector Pin Layout Diagram
AC
Positioning piece *2
DC
Positioning piece *2
2
2
3
1
3
1
4
4
Note: Leakage current from indicator circuit may cause load malfunction (i.e., the load may remain ON). Make sure that the load operating current is higher
than the leakage current. For countermeasures, refer to technical support on your OMRON website.
*1. Light-ON when not operating means the indicator is lit when the actuator is free and is not light when the Switch contacts (NO) close when the
actuator rotates or is pushed down.
*2. The position of the positioning piece is not always the same. If using an L-shaped connector causes problems in application, use a straight connector.
Connecting Sensor I/O connector cable (Socket)
Type
AC/DC Type
Number of cable cores
2
AC
4
M12 Screw (Straight)
2
DC
Cable length
L (m)
Model
2m
XS2F-A421-DB0-F
5m
XS2F-A421-GB0-F
2m
XS2F-A421-D90-F
5m
XS2F-A421-G90-F
2m
XS2F-D421-DD0
5m
XS2F-D421-GD0
2m
XS2F-D421-DA0-F
5m
XS2F-D421-GA0-F
2m
XS2F-D421-D80-F
5m
XS2F-D421-G80-F
2m
XS5F-D421-D80-F
5m
XS5F-D421-G80-F
4
M12 Smart click type (Straight)
DC
16
4
Applicable limit switch models
WL@-@K13A-N
WL@-@K43A-N
WL@-@-AGJ-N
WL@-@K13-N
WL@-@-M1J-N
WL@-@-M1GJ@-N
WL@-@K43-N
WL@-@-M1JB-N
WL@-@DGJ-N
WL@-@-M1TJ-N
WL@-@-M1TJB-N
WL-N/WLM-N
Dimensions (Unit: mm)
XS2F-@421-@@0-@
XS2F-D421-@D0
L (Cable length)
40.7
6 dia.
14.9 dia.
DC
AC
30
5
50
Wiring Diagram
Two-core model
AC/DC Type
Model
Terminal No.
XS2F-A421-DB0-F
XS2F-A421-GB0-F
AC
1
2
3
4
Terminal No.
XS2F-D421-DD0
XS2F-D421-GD0
1
2
3
4
DC
Terminal No.
XS2F-D421-DA0-F
XS2F-D421-GA0-F
1
2
3
4
XS5F-D421-@80-F
Model
Wiring Diagram
Cable color of
core sheath
Brown
Blue
XS2F-A421-D90-F
XS2F-A421-G90-F
Cable color of
core sheath
Terminal No.
1
2
3
4
Blue
Brown
Cable color of
core sheath
Cable color of
core sheath
Brown
White
Blue
Black
XS2F-D421-D80-F
XS2F-D421-G80-F
Brown
Blue
Wiring Diagram
L (Cable length)
40.7
Four-core model
Wiring Diagram
AC/DC Type
6 dia.
Model
Four-core model
Wiring Diagram
Terminal No.
14.9 dia.
5
30
50
DC
XS5F-D421-D80-F
XS5F-D421-G80-F
1
2
3
4
Cable color of
core sheath
Brown
White
Blue
Black
17
WL-N/WLM-N
Environment-resistant Switches
Standard Switches
Actuator
Item
Pretravel (PT)
Hermetic
seal
Molded
terminals,
-141 models
Model
WLCA2-255-N
-----
-----
MAX20°
WLCA2-2N55-N
-----
-----
High-sensitivity
10° +2°
-1°
WLG2-55-N
-----
-----
High-precision
5° +2°0°
WLGCA2-55-N
-----
15±5°
WLCA2-139-N
25±5°
WLCA2-2139-N
-----
-----
MAX20°
WLCA2-2N139-N
-----
-----
High-sensitivity
10° +2°
-1°
WLG2-139-N
-----
-----
High-precision
5° +2°0°
WLGCA2-139-N
-----
15±5°
WLCA2-140-N
Basic
Basic
25±5°
WLCA12-55-N
Model
25±5°
WLCA12-139-N
WLCA12-140-N
----WLCL-139-N
----WLCL-140-N
-----
-----
WLCA2-2N140-N
-----
-----
High-sensitivity
10° +2°
-1°
WLG2-140-N
-----
-----
High-precision
5° +2°0°
Basic
-----
WLCL-55-N
MAX20°
-----
-----
WLCA2-141-N
25±5°
-----
-----
MAX20°
-----
-----
-----
-----
-----
10° +2°
-1°
High-precision
5° +2°0°
WLGCA2-141-N
15±5°
WLCA2-RP60-N
25±5°
WLCA2-2RP60-N
Basic
-----
15±5°
High-sensitivity
Anti-coolant
WLCA12-141-N
WLG2-141-N
MAX20°
---------
----WLCA12-RP60-N
----WLCL-RP60-N
-----
-----
-----
-----
-----
-----
-----
High-sensitivity
10° +2°
-1°
High-precision
5° +2°0°
WLGCA2-RP60-N
15±5°
WLCA2-TH-N
WLCA12-TH-N
WLCL-TH-N
25±5°
WLCA2-2TH-N
WLCA12-2TH-N
WLCL-2TH-N
MAX20°
WLCA2-2NTH-N
WLCA12-2NTH-N
WLCL-2NTH-N
High-sensitivity
10° +2°
-1°
WLG2-TH-N
WLG12-TH-N
WLGL-TH-N
High-precision
5° +2°0°
WLGCA2-TH-N
15±5°
WLCA2-TC-N
WLCA12-TC-N
WLCL-TC-N
25±5°
WLCA2-2TC-N
WLCA12-2TC-N
WLCL-2TC-N
MAX20°
WLCA2-2NTC-N
WLCA12-2NTC-N
WLCL-2NTC-N
High-sensitivity
10° +2°
-1°
WLG2-TC-N
WLG12-TC-N
WLGL-TC-N
High-precision
5° +2°0°
WLGCA2-TC-N
15±5°
WLCA2-RP-N
25±5°
-----
-----
MAX20°
-----
-----
-----
-----
-----
Basic
Heat-resistant
Basic
Low-temperature
Basic
Corrosion-proof
Weather-proof
Model
Adjustable rod lever
25 to 140mm
WLCA2-55-N
Basic
Molded
terminals,
-140 models
Adjustable roller lever
15±5°
Airtight seal
Molded
terminals,
-139 models
Roller lever R38
WLG2-RP60-N
High-sensitivity
10° +2°
-1°
High-precision
5° +2°0°
WLGCA2-RP-N
15±5°
WLCA2-P1-N
25±5°
-----
MAX20°
-----
Basic
High-sensitivity
10° +2°
-1°
-----
-----
-----
----WLCA12-RP-N
WLG2-RP-N
WLG2-P1-N
-----
----WLCL-RP-N
-----
----WLCA12-P1-N
----WLCL-P1-N
---------
WLG12-P1-N
WLGL-P1-N
Note: The maximum cable length for a Hermetic Switch is 5 m.
Actuator
Sealed top-roller
plunger
Model
Airtight
Hermetic
Horizontal plunger
Model
Model
Coil spring
(spring diameter: 6.5)
Model
Resin rod
(rod diameter: 8)
Model
WLD28-55-N
WLSD-55-N
WLSD2-55-N
WLNJ-55-N
WLNJ-255-N
Molded
terminals,
-139 models
WLD28-139-N
WLSD-139-N
WLSD2-139-N
WLNJ-139-N
WLNJ-2139-N
Molded
terminals,
-140 models
WLD28-140-N
WLSD2-140-N
WLNJ-140-N
WLNJ-2140-N
WLNJ-2RP60-N
Anti-coolant
Heat-resistant
Low-temperature
Corrosion-proof
-----
WLD28-RP60-N
WLSD-RP60-N
WLSD2-RP60-N
WLNJ-RP60-N
WLD28-TH-N
WLSD-TH-N
WLSD2-TH-N
WLNJ-TH-N
-----
-----
WLSD-TC-N
WLSD2-TC-N
WLNJ-TC-N
-----
WLD28-RP-N
WLSD-RP-N
WLSD2-RP-N
WLNJ-RP-N
WLNJ-2RP-N
Note: The maximum cable length for a Hermetic Switch is 5 m.
18
Horizontal-roller
plunger
WL-N/WLM-N
Environment-resistant Switches
Operation indicator Switches
Airtight Switches
Actuator
Roller lever: R38
Indicator
Item
Basic
Neon lamp
Pretravel (PT)
Adjustable roller lever
Model
Adjustable rod lever:
25 to 140mm
Model
Model
15±5°
WLCA2-55LE-N
WLCA12-55LE-N
25±5°
WLCA2-255LE-N
-----
---------
MAX20°
WLCA2-2N55LE-N
-----
-----
High-sensitivity
10° +2°
-1°
WLG2-55LE-N
-----
-----
High-precision
5° +2°0°
WLGCA2-55LE-N
-----
-----
15±5°
WLCA2-55LD-N
25±5°
WLCA2-255LD-N
-----
-----
MAX20°
WLCA2-2N55LD-N
-----
-----
Basic
LED
WLCA12-55LD-N
WLCL-55LD-N
High-sensitivity
10° +2°
-1°
WLG2-55LD-N
-----
-----
High-precision
5° +2°0°
WLGCA2-55LD-N
-----
-----
Horizontal plunger
Horizontal-roller
plunger
Sealed top-roller
plunger
Actuator
Indicator
Item
Model
Neon lamp
Basic
WLD28-55LE-N
LED
Basic
WLD28-55LD-N
Coil spring
(spring diameter: 6.5)
Model
Model
Model
-----
-----
-----
WLSD-55LD-N
WLSD2-55LD-N
WLNJ-55LD-N
Resin rod
(rod diameter: 8)
Model
----WLNJ-255LD-N
Hermetic Switches
Actuator
Item
Molded
terminals,
-139 models
Molded
terminals,
-141 models
Basic
Roller lever: R38
Wiring specification
NC wiring
Pretravel (PT)
Model
NO wiring
Model
15±5°
WLCA2-139LD2-N
WLCA2-139LD3-N
25±5°
WLCA2-2139LD2-N
WLCA2-2139LD3-N
MAX20°
-----
High-sensitivity
10° +2°
-1°
-----
High-precision
5° +2°0°
WLGCA2-139LD2-N
WLGCA2-139LD3-N
15±5°
WLCA2-141LD2-N
WLCA2-141LD3-N
Basic
25±5°
-----
MAX20°
-----
High-sensitivity
10° +2°
-1°
High-precision
5° +2°0°
Basic
Anti-coolant
WLG2-141LD2-N
-----
----WLG2-139LD3-N
--------WLG2-141LD3-N
-----
15±5°
WLCA2-RP60LD2-N
WLCA2-RP60LD3-N
25±5°
WLCA2-2RP60LD2-N
WLCA2-2RP60LD3-N
MAX20°
-----
-----
High-sensitivity
10° +2°
-1°
WLG2-RP60LD2-N
WLG2-RP60LD3-N
High-precision
5° +2°0°
WLGCA2-RP60LD2-N
WLGCA2-RP60LD3-N
Note: The maximum cable length for a Hermetic Switch is 5 m.
19
WL-N/WLM-N
Spatter-prevention Switches
Actuator
Roller lever: R38
Sealed top-roller
plunger
Double Nut Lever
Indicator
Neon lamp
LED
Item
Pretravel (PT)
Allen-head Lever
Model
Model
WLCA2-LES-N
Model
Basic
15±5°
WLCA2-LEAS-N
High-sensitivity
10° +2°
-1°
WLG2-LEAS-N
High-precision
5° +2°0°
Basic
15±5°
WLCA2-LDAS-N
WLCA2-LDS-N
High-sensitivity
10° +2°
-1°
WLG2-LDAS-N
WLG2-LDS-N
-----
High-precision
5° +2°0°
WLGCA2-LDS-N
-----
-----
-----
WLD28-LES-N
WLG2-LES-N
-----
WLGCA2-LES-N
----WLD28-LDS-N
Long-life Switches
Item
Actuator
Roller lever: R38,
screw terminals
Roller lever,
direct-wired
connector
High-sensitivity 10° +2°
-1°
High-precision 5° +2°0°
Model
Model
Model
WLMCA2-LD-N
2 conductors
WLMGCA2-LD-N
AC
WLMCA2-LDK13A-N
WLMG2-LDK13A-N
WLMGCA2-LDK13A-N
DC
WLMCA2-LDK13-N
WLMG2-LDK13-N
WLMGCA2-LDK13-N
WLMCA2-LDK43A-N
WLMG2-LDK43A-N
DC
WLMCA2-LDK43-N
WLMG2-LDK43-N
WLMGCA2-LDK43-N
2 conductors
DC
WLMCA2-LD-M1J-N
WLMG2-LD-M1J-N
WLMGCA2-LD-M1J-N
4 conductors
DC
WLMCA2-LD-DGJ-N
WLMG2-LD-DGJ-N
*1. The default setting is light-ON when not operating (NO wiring).
Turn the lamp holder by 180° to change the setting to light-ON when operating (NC wiring).
(Ask your OMRON representative for information on 2-conductor models.)
*2. With 0.3-m cable.
20
WLMG2-LD-N
AC
4 conductors
Roller lever,
pre-wired connector
*2
Operation indicator (LED) *1
Basic 15±5°
-----
-----
WL-N/WLM-N
Individual Parts
Switches without Levers, Heads, and Actuators
General-purpose Parts
Actuator
Item
Pretravel (PT)
Set
Switch without
levers
Model
Basic
Roller lever
High-sensitivity
Basic
Adjustable roller
lever
High-sensitivity
Variable rod lever
High-sensitivity
Fork lever lock
Basic
Top plunger
Horizontal plunger
25±5°
WLCA2-2-N
WLRCA2-2-N
WL-3H1100-N
MAX20°
WLCA2-2N-N
WLRCA2-2N-N
WL-1H1100-N
WL-1H1100-N
10° +2°
-1°
WLG2-N
WLRG2-N
WL-2H1100-N
15±5°
WLCA12-N
WLRCA2-N
WL-1H2100-N
25±5°
WLCA12-2-N
WLRCA2-2-N
WL-3H2100-N
MAX20°
WLCA12-2N-N
WLRCA2-2N-N
WL-1H2100-N
+2°
-1°
WLG12-N
WLRG2-N
WL-2H2100-N
15±5°
WLCL-N
WLRCA2-N
WL-1H4100-N
25±5°
WLCL-2-N
WLRCA2-2-N
WL-3H4100-N
MAX20°
WLCL-2N-N
WLRCA2-2N-N
WL-1H4100-N
10° +2°
-1°
WLGL-N
WLRG2-N
WL-2H4100-N
MAX
2.8 mm
20±10 mm
Flexible rod
Model
WLRCA2-N
MAX
1.7 mm
Basic
Model
WLCA2-N
MAX55°
Basic
Actuator only *2
15±5°
10°
Basic
Head *1
(with Actuators)
Basic
40±20 mm
WL-1A100
WL-2A100
WL-4A100
WLCA32-41-N
WL-5H5100-N
WL-5A100
WLCA32-42-N
WL-5H5102-N
WL-5A102
WL-5H5104-N
WL-5A104
WLCA32-44-N
WL-5H5104-N
WL-5A104
WLD18-N
WL-7H100-N
-----
WL-7H400-N
-----
WLCA32-43-N
WLD28-N
WLRCA32-N
-----
WLD38-N
WL-7H300-N
-----
WLSD-N
WL-8H100-N
-----
WL-8H200-N
-----
WLSD2-N
-----
WLSD3-N
WL-8H300-N
-----
WLNJ-N
WL-9H100-N
-----
WL-9H200-N
-----
WL-9H300-N
-----
WL-9H400-N
-----
WLNJ-30-N
WLNJ-2-N
-----
WLNJ-S2-N
*1. The heads are not compatible with WL-series switches.
*2. The same actuators can be used for both WL and WL-N switches.
Spatter-prevention Parts
Actuator
Lever Type
Allen-head bolt
lever
Item
Basic
High-sensitivity
Roller lever
Double nut lever
Basic
High-sensitivity
Set
Switch without
levers
Head *1
(with Actuators)
Actuator only *2
Model
Model
Model
WLCA2-LES-N
WLRCA2-LES-N
WLCA2-LDS-N
WLRCA2-LDS-N
WLG2-LDS-N
WLRG2-LDS-N
WLCA2-LEAS-N
WLRCA2-LES-N
WLCA2-LDAS-N
WLRCA2-LDS-N
WLG2-LDAS-N
WLRG2-LDS-N
WL-1H1100S-N
WL-1A103S
WL-2H1100S-N
WL-1A105S
*1. The heads are not compatible with WL-series switches.
*2. The same actuators can be used for both WL and WL-N switches.
Covers with Indicators (See Note.)
General-purpose Parts
Cover
Item
Spatter-prevention Parts
Cover only *
Model
Cover
Item
Cover only *
Model
Neon lamp
WL-LE-N
Neon lamp
WL-LES-N
LED
WL-LD-N
LED
WL-LDS-N
* The covers are not compatible with WL-series switches.
Note: The default setting is for light-ON when not operating.
Turn the lamp holder by 180° to change the setting to light-ON
when operating.
21
WL-N/WLM-N
Specifications
General-purpose/ Environment-resistant Switches
Ratings
Screw Terminals
Non-inductive load (A)
Rated voltage
(V)
Item
Resistive load
NC
Basic or high-precision
High-sensitivity Switches
Note: 1.
2.
3.
4.
5.
NO
Inductive load (A)
Lamp load
NC
NO
Inductive load
NC
NO
Motor load
NC
NO
5
3
1.5
2.5
1.5
0.8
AC
125
250
500
10
10
10
3
2
1.5
1.5
1
0.8
10
10
3
DC
8
14
30
125
250
10
10
6
0.8
0.4
6
6
4
0.2
0.1
3
3
3
0.2
0.1
10
10
6
0.8
0.4
6
6
4
0.2
0.1
AC
125
250
5
5
----
----
----
DC
125
250
0.4
0.2
----
----
----
The above figures are for steady-state currents.
Inductive loads have a power factor of 0.4 min. (AC) and a time constant of 7 ms max. (DC).
A lamp load has an inrush current of 10 times the steady-state current.
A motor load has an inrush current of 6 times the steady-state current.
For PC loads, use the microload models.
Inrush current
NC
30 A max.(15 A max. *)
NO
20 A max.(10 A max. *)
* For high-sensitivity switches.
Minimum applicable load
5 VDC 1 mA, resistive load, P level
Operation indicator Switches
Model
WL-LE-N
WL-LD-N
Item
Neon lamp
LED
Max. rated voltage
Leakage current (mA)
125 AC
Approx. 0.6
250 AC
Approx. 1.9
10 to 24 VAC/DC
Approx. 0.4
115 VAC/DC
Approx. 0.5
Characteristics
Degree of protection
Durability *1
IP67
Mechanical
15,000,000 operations min. *2
Electrical
750,000 operations min. *3
Operating speed
Operating frequency
1 mm/s to 1 m/s (in case of WLCA2-N)
Mechanical
120 operations/minute min.
Electrical
30 operations/minute min.
Rated frequency
50/60 Hz
Insulation resistance
100 MΩ min. (at 500 VDC)
Contact resistance
Dielectric strength
25 mΩ max. (initial value for the built-in switch when tested alone)
Between terminals of the same polarity
1,000 VAC (600 VAC), 50/60 Hz for 1 min
Between currentcarrying metal part and ground
2,200 VAC (1,500 VAC), 50/60 Hz for 1 min *4
Between each terminal and non-currentcarrying metal part 2,200 VAC (1,500 VAC), 50/60 Hz for 1 min *4
Vibration resistance
Malfunction
10 to 55 Hz, 1.5-mm double amplitude *5
Shock
resistance
Destruction
1,000 m/s2 max.
Malfunction
300 m/s2 *5
Ambient operating temperature
-10 to +80°C (with no icing) *6
Ambient operating humidity
35% to 95% RH
Weight
Approx. 255 g (in case of WLCA2-N)
Note: 1. The above figures are initial values.
2. The figures in parentheses for dielectric strength are those for the high-sensitivity switches models.
*1. The values are calculated at an operating temperature of +5°C to +35°C and an operating humidity of 40% to 70% RH. Contact your OMRON
sales representative for more detailed information on other operating environments.
*2. High-sensitivity switches and switches with flexible rod actuators: 10 million operations min.
500,000 operations min. for weather-proof models.
*3. Durability is 500,000 operations min. for high-sensitivity models.
500,000 operations min. for weather-proof models.
Contact your OMRON representative for information on environment-resistant switches.
*4. Switches with Connectors: 1,500 V.
*5. Except switches with flexible rod actuators.
*6. For low-temperature models this is -40°C to +40°C (with no icing). For heat-resistant models the range is +5°C to +120°C.
22
WL-N/WLM-N
Spatter-prevention Switches
Ratings
Screw Terminals
Non-inductive load (A)
Rated voltage
(V)
Item
Resistive load
NC
WL@-LES-N
(Without high-sensitivity overtravel models)
WL@-LDS-N
(Without high-sensitivity overtravel models)
Note: 1.
2.
3.
4.
NO
Inductive load (A)
Lamp load
NC
NO
3
2
1.5
1
Inductive load
NC
NO
Motor load
NC
NO
10
10
5
3
2.5
1.5
5
AC
125
250
10
10
AC
115
10
3
1.5
10
DC
12
24
115
10
6
0.8
6
4
0.2
3
3
0.2
10
6
0.8
2.5
6
4
0.2
The above figures are for steady-state currents.
Inductive loads have a power factor of 0.4 min. (AC) and a time constant of 7 ms max. (DC).
A lamp load has an inrush current of 10 times the steady-state current.
A motor load has an inrush current of 6 times the steady-state current.
* Refer to the rating of a General-purpose / Weather-proof Switches type for the rating of a high-sensitivity overtravel type.
Inrush current
NC
30 A max.(15 A max. *)
NO
20 A max.(10 A max. *)
* For high-sensitivity switches.
Minimum applicable load
5 VDC 1 mA, resistive load, P level
Characteristics
Degree of protection
Durability *1
IP67
Mechanical
Electrical
Operating speed
Operating frequency
15,000,000 operations min. *2
750,000 operations min. (3 A at 250 VAC, resistive load) *3
1 mm/s to 1 m/s (in case of WLCA2-LDS-N)
Mechanical
Electrical
120 operations/minute min.
30 operations/minute min.
Rated frequency
50/60 Hz
Insulation resistance
100 MΩ min. (at 500 VDC)
Contact resistance
Dielectric strength
25 mΩ max. (initial value for the built-in switch when tested alone)
Between terminals of the same polarity
1,000 VAC (600 VAC), 50/60 Hz for 1 min
Between currentcarrying metal part and ground
2,200 VAC (1,500 VAC), 50/60 Hz for 1 min *4
Between each terminal and non-currentcarrying metal part 2,200 VAC (1,500 VAC), 50/60 Hz for 1 min *4
Vibration resistance
Malfunction
10 to 55 Hz, 1.5-mm double amplitude
Shock
resistance
Destruction
1,000 m/s2 max.
Malfunction
300 m/s2
Ambient operating temperature
-10 to +80°C (with no icing)
Ambient operating humidity
35% to 95% RH
Weight
Approx. 255 g (in case of WLCA2-LDS-N)
Note: 1. The above figures are initial values.
2. The figures in parentheses for dielectric strength are those for the highsensitivity overtravel models.
*1. The values are calculated at an operating temperature of +5°C to +35°C and an operating humidity of 40% to 70% RH. Contact your OMRON
sales representative for more detailed information on other operating environments.
*2. Durability is 10,000,000 operations min. for high-sensitivity models.
*3. Durability is 500,000 operations min. for high-sensitivity models.
500,000 operations min. for weather-proof models.
Contact your OMRON representative for information on Airtight Switches.
*4. Switches with Connectors: 1,500 V.
23
WL-N/WLM-N
Long-life Switches
Ratings
Screw Terminal Switches
Direct-wired Connector and Pre-wired Connector Switches
Non-inductive load (A)
Rated
voltage
(V)
Item
Resistive
load
NC
Basic or
high-precision
High-sensitivity
Inrush current
NO
Lamp
load
Inductive load (A)
Inductive
load
NC
NO
Motor
load
NC
NO
115 AC
10
3
1.5
10
NC
NO
5
2.5
12 DC
24 DC
115 DC
10
6
0.8
6
4
0.2
3
3
0.2
10
6
0.8
6
4
0.2
115 AC
5
—
—
—
115 DC
0.4
—
—
—
NC
30 A max. (15 A max. *)
NO
20 A max. (10 A max. *)
* For high-sensitivity overtravel models.
Minimum applicable load
5 VDC 1 mA, resistive load, P level
Characteristics
Degree of protection
Durability *1
30,000,000 operations min.
Electrical
30,000,000 operations min. (10 mA at 24
VDC, resistive load)
750,000 operations min. (3 A at 115 VAC,
resistive load)
High-sensitivity Switches: 500,000 operations min. (3 A at 115 VAC, resistive load)
Operating speed
Operating
frequency
IP67
Mechanical
Mechanical
Electrical
1 mm/s to 1 m/s (for WLMCA2-LD-N)
120 operations/minute
30 operations/minute
Rated frequency
50/60 Hz
Insulation resistance
100 MΩ min. (at 500 VDC)
Contact resistance
25 mΩ max. (initial value for the built-in
switch when tested alone)
Between terminals of the 1,000 VAC (600 VAC), 50/60 Hz for 1 min
same polarity
Dielectric
strength (50/
60 Hz for 1
min)
Vibration resistance
Shock resistance
Between current-carrying
metal part
and ground
2,200 VAC (1,500 VAC), 50/60 Hz for 1 min
*2
Between
each terminal
2,200 VAC (1,500 VAC), 50/60 Hz for 1 min
and non-cur*2
rent-carrying
metal part
Malfunction
10 to 55 Hz, 1.5-mm double amplitude
Destruction
1,000 m/s2 max.
Malfunction
300 m/s2 max.
Ambient operating temperature
–10°C to +80°C (with no icing)
Ambient operating humidity
35% to 95%RH
Weight
Approx. 255 g (for WLMCA2-LD-N)
Note: 1. The above figures are initial values.
2. The figures in parentheses for dielectric strength are for the
High-sensitivity Switches.
*1. The values are calculated at an operating temperature of +5°C to
+35°C, and an operating humidity of 40% to 70%RH. Contact
your OMRON sales representative for more detailed information
on other operating environments.
*2. Switches with Connectors: 1,500 V.
24
Non-inductive load (A)
Model
Rated
voltage
(V)
Resistive
load
NC
Basic or
high-precision
High-sensitivity
NO
115 AC
3
12 DC
24 DC
115 DC
3
3
0.8
Lamp
load
NC
NO
3
1.5
Inductive load (A)
Inductive
load
NC
NO
3
Motor
load
NC
NO
3
2.5
3
3
0.2
3
3
0.8
3
3
0.2
115 AC
3
—
—
—
115 DC
0.4
—
—
—
Note: 1. The above figures are for steady-state currents.
2. Inductive loads have a power factor of 0.4 min. (AC) and a
time constant of 7 ms max. (DC).
3. A lamp load has an inrush current of 10 times the steadystate current.
4. A motor load has an inrush current of 6 times the steadystate current.
WL-N/WLM-N
General-purpose/ Environment-resistant/ Spatter-prevention Switches
Approved Standards
Agency
Standard
File No.
Approved models
Contact your OMRON representative for information
Contact your OMRON representative for information
UL508
UL
CSA C22.2 No.14
TÜV Rheinland
EN60947-5-1
CCC (CQC)
GB14048.5
Approved Standard Ratings
UL/cUL (UL508, CSA C22.2 No.14)
Specifications
Indicator
Sensor I/O connectors
Approved Standards
Item
Basic Switches
A600
1 A, 125 VDC
High-sensitivity or high-precision
B600
0.5 A, 125 VDC
Pre-wired Connector (AC)
Basic, high-sensitivity, or high-precision
C300
3 A, 250 VAC
Pre-wired Connector (DC)
Direct-wired Connector (DC)
Basic Switches
1 A, 125 VDC
No Connector
No indicator
High-sensitivity or high-precision
0.5 A, 125 VDC
Basic Switches
A300
10 A, 250 VAC
High-sensitivity or high-precision
B300
5 A, 250 VAC
Basic, high-sensitivity, or high-precision
C300
3 A, 250 VAC
Basic Switches
A150
10 A, 115 VAC
1 A, 115 VDC
High-sensitivity or high-precision
B150
5 A, 115 VAC
0.5 A, 115 VDC
Pre-wired Connector (AC)
Basic, high-sensitivity, or high-precision
C150
3 A, 115 VAC
Pre-wired Connector (DC)
Direct-wired Connector (DC)
Basic Switches
1 A, 115 VDC
High-sensitivity or high-precision
0.5 A, 115 VDC
No Connector
Neon lamp
Pre-wired Connector (AC)
No Connector
LED
A600 Authentication conditions
Rated voltage
120 VAC
240 VAC
480 VAC
600 VAC
Energizing current
10 A
Current (A)
Volt-ampere (VA)
Make
Break
Make
Break
60
30
15
12
6
3
1.5
1.2
7,200
720
B600 Authentication conditions
Rated voltage
120 VAC
240 VAC
480 VAC
600 VAC
Energizing current
5A
Current (A)
Volt-ampere (VA)
Make
Break
Make
Break
30
15
7.5
6
3
1.5
0.75
0.6
3,600
360
C300 Authentication conditions
Rated voltage
120 VAC
240 VAC
Energizing current
2.5 A
Current (A)
Volt-ampere (VA)
Make
Break
Make
Break
15
7.5
1.5
0.75
1,800
180
A300 Authentication conditions
Rated voltage
120 VAC
240 VAC
Energizing current
10 A
Current (A)
Make
60
30
Break
6
3
Volt-ampere (VA)
Make
Break
7,200
720
25
WL-N/WLM-N
B300 Authentication conditions
Rated voltage
Energizing current
120 VAC
240 VAC
5A
Current (A)
Volt-ampere (VA)
Make
Break
Make
Break
30
15
3
1.5
3,600
360
A150 Authentication conditions
Rated voltage
Energizing current
120 VAC
10 A
Current (A)
Volt-ampere (VA)
Make
Break
Make
Break
60
6
7,200
720
Make
Break
Make
Break
30
3
3,600
360
Make
Break
Make
Break
15
1.5
1,800
180
B150 Authentication conditions
Rated voltage
Energizing current
120 VAC
5A
Current (A)
Volt-ampere (VA)
C150 Authentication conditions
Rated voltage
Energizing current
120 VAC
2.5 A
Current (A)
Volt-ampere (VA)
TÜV (EN 60947-5-1)
(Certification Only for Switches with Ground Terminals and DC Switches with Connectors)
Specification
Authentication conditions
With ground terminals
No indicator
Neon lamp
With DC Connector
LED
Working load category
AC-15
DC-12
AC-15
AC-15
DC-12
DC-12
Rated working voltage (Ue)
250 V
48 V
250 V
115 V
48 V
48 V
Rated working current (Ie)
2A
Conditional short-circuit current
100 A
Short-circuit protective device (SCPD)
10 A, fuse type gG
Rated insulation voltage (Ui)
Rated impulse dielectric strength (Uimp)
250 V
48 V
4 kV
800 V
Pollution degree
3
Class I
Electric shock protection class
Class III
CCC (GB14048.5)
Authentication conditions
LED
Neon lamp
With DC Connector With AC Connector
Working load category
AC-15
DC-13
AC-15
AC-15
DC-13
DC-13
AC-15
Rated working voltage (Ue)
250 V
48 V
250 V
250 V
48 V
48 V
250 V
Rated working current (Ie)
Conditional short-circuit current
Short-circuit protective device (SCPD)
Rated insulation voltage (Ui)
26
Specification
No indicator
2A
1000 A
10 A, fuse type gG
250 V
WL-N/WLM-N
Structure and Nomenclature
Structure
General-purpose Switches: WLCA2-N
Actuator
Head-mounting Screws
Roller
The roller is made of self-lubricating
sintered stainless steel and boasts high
resistance to wear.
Head
Lever
The lever is forged from corrosion-resistant
aluminum alloy. It provides superior
corrosion resistance and outstanding
strength.
With roller lever, adjustable rod and flexible
rod models, the actuator position can be set
anywhere within 360°. (The lever cannot be
mounted in the opposite direction.)
You can remove the two screws to
mount the switch in any of the four
possible orientations.
Shaft Section Seal
An oil seal is fitted on the inlet of the
shaft section to maintain a tight seal.
Roller Lever Bolt
Operational Plunger
Set Position Marker Plate
Set the indicator needle so
that it is between protrusions
on the bearing section on the
marker plate after operation.
Head
Set position marker plate
You can change the direction of the
operational plunger to electrically switch
the direction of operation between both
sides, left only, or right only.
Built-in Switch
Built-in switch with SPST-NO+NC
contact form.
Requires maintenance (excessive overtravel)
Proper range
Requires maintenance (insufficient overtravel)
Proper range
Terminal Screws
Four, M3.5 screws
Requires maintenance (excessive overtravel)
Cover Setscrew
A combination Philips-slotted screw is used.
A retainer prevents the screw from falling
from the cover even when the screw is loose.
Cover
Conduit Opening *1
The conduit screw is a parallel screw
for G1/2 piping, and is used together
with an SC connector to maintain a
tight seal.
Cover Seal
High sealing performance is achieved. The
seal also serves as a spacer.
There is no troublesome insulating paper,
making it easy to work with the switch.
*1. The available conduit screws are Pg 13.5, M20 and 1/2-14 NPT.
27
WL-N/WLM-N
Indicators
Indicator Covers
Indicator
The indicator covered if outsert molded
from diecast aluminum and has outstanding
sealing properties.
The indicator is either a neon lamp or an
LED. Switches with LED indicators have a
built-in rectifier stack, so there is no
connection polarity.
Indicator Windows
Operating status (i.e., light-ON when
operating or light-ON when not operating)
depends on whether a neon lamp or an
LED is used.
Contact Spring
Light-ON when Operating/Not Operating
Lamp Holder
Indicators can be switched from light-ON
when operating and light-ON when not
operating, by simply rotating the indicator
holder by 180°.
Light-ON when Operating
Use the terminal screws on the built-in
switch to connect to the lamp terminals.
A coil spring is used to make contact, so
connecting to the lamp terminals is not
necessary.
Light-ON when Not Operating
LED at top
Light-ON when not operating
LED at bottom
Operation
Internal Circuits
Power
Neon lamp
Built-in switch
14
Light-ON when
operating *1
Za
13
Contact spring
WL-LE-N
12
11
Resistor
Load
Internal
circuits
WL-LE-N
WL-LD-N
Power
Rectifier stack
Contact spring
Internal
circuits
Resistor
Light-ON when
not operating *2
Za
14
13
12
11
Built-in switch
Load
WL-LD-N
Zener
diode
Rated
current
diode
Resistor
LED
Note: 1. Leakage current from indicator circuit may cause load malfunction (i.e., the load may remain ON). Make sure that the load operating
current is higher than the leakage current.
For countermeasures, refer to technical support on your OMRON website.
*1. Light-ON when operating means that the lamp lights when the limit switch contacts (NC) release, or when the actuator rotates or is pushed
down.
*2. Light-ON when not in operation means that the lamp remains lit when the actuator is free, or when the limit switch contacts (NO) close when
the actuator rotates or is pushed down.
28
WL-N/WLM-N
Environment-resistant Switches
Molding Specifications for Hermetic Switches
WL@-139-N
: Molded parts
WL@-140-N
WL@-141-N
Head cap
Airtight
built-in switch
Standard
built-in switch
WL@-145-N
Head cap
Oil seal
WL@-RP40-N
Airtight
built-in switch
WL@-RP60-N
Oil seal
Airtight
built-in switch
Airtight
built-in switch
Airtight
built-in switch
* Fluorine rubber
is used for all
rubber parts.
Model
Cable specifications
WL@-139-N
WL@-140-N
WL@-141-N
WL@-145-N
WL@-RP40-N
WL@-RP60-N
Connector type
Resin cap
Standard 5-m VCT cable, with high flexibility and good
anti-oil properties attached. Finished outer diameter:
11.5 mm, 4 conductors.
Metal connector
Resin connector *
Resin cap
* The connector can be removed, so it is possible to use flexible conduit for the cable.
29
WL-N/WLM-N
Spatter-prevention Switches: WLCA2-LES-N
Actuator
Roller, Roller Axis
Using stainless steel prevents
spatter from adhering.
Operating Lever
A baking finish is applied to the surface
so that any adhering spatter is easily
removed.
Roller Lever Bolt
Stainless steel construction to prevent
spatter adherence.
Double nut models are also available.
Screws
Externally visible screws on the head and
cover are made of stainless steel to prevent
spatter adherence.
Head Cap
Using fluororesin prevents spatter from
adhering.
* Spatter means the zinc powder produced
when welding.
Adhering spatter to the limit switch may
cause malfunction of lever or lamp cover.
The lack of gap prevents spatter
powder from clogging.
30
WL-N/WLM-N
Long-life Switches
Head Cap
Head
The head cap helps prevent the entry of cutting
chips.You can use the protrusion on the cap to
confirm the set position.
You can remove the two screws to mount the head in
any of the four possible directions.
Actuator
Shield Structure
Roller
A head cap and oil seal form a double-seal structure.
Excellent durability and reliability are ensured.
The roller is made of self-lubricating sintered
stainless steel.
It provides superior resistance to wear.
Lever
The lever is forged from anti-corrosive aluminum
alloy. It provides superior corrosion resistance and
outstanding strength. With a roller lever actuator,
the actuator position can be set anywhere within
360°. (The lever cannot be mounted in the opposite
direction.)
Oil seal
Head cap
Operating Plunger
PEEK resin is used. It provides superior resistance to
wear. You can change the mounting direction to use
any one of the three operating directions (both sides,
left side, or right side).
Built-in Switch
Built-in switch with an
SPST-NO+NC contact form.
Cover Seal
High sealing performance is achieved. The seal also
serves as a spacer.
There is no troublesome insulating paper, making it
easy to work with the Switch.
Terminal Screws
Four, M3.5 screws.
Cover Setscrew
Conduit Opening
In addition to parallel threads for G1/2 tubing,
direct-wired and pre-wired connectors have been
added to the series.
Cover
A combination Philips-slotted screw is used.
A retainer prevents the screw from falling
from the cover even when the screw is loose.
31
WL-N/WLM-N
Dimensions and Operating Characteristics
(Unit: mm)
General-purpose Switches
Standard Switches
Switches with Roller Lever Actuators
Basic, High-sensitivity, and High-precision Switches
Roller lever R38
Basic
High-sensitivity
WLCA2-N
WLG2-N
WLCA2-2-N
WLCA2-2N-N
17.5×7 dia. *
Roller lever R50
Basic
WLCA2-7-N
High-precision
WLGCA2-N
60 max.
53±1.5
41.5±1.5
40±1.5
25.4
13.1
Two, M3.5
17.5×15 dia. *
12.7
12.7
Four, 5.2 dia.
holes
25.4
M5
Allen-head bolt
14.7
(137) 14.7
68.7
Three, M4
21.6
(15.1)
29.2±1.2
42 max.
53.2±0.8
JIS B 0202 G½
30.2±0.2
40±0.7
68.7
58.7±0.2
5
(4.9)
25.4
M5
Allen-head bolt
Four, 5.2 dia. holes
58.7±0.2
25.4
13.1
Two, M3.5
R50
R38
(125)
67.2 max.
58.1±1.5
41.5±1.5
36±1.5
Three, M4
5
Four, M6
Depth: 15 min.
21.6
(4.9)
JIS B 0202 G½
(15.1)
29.2±1.2
42 max.
53.2±0.8
30.2±0.2
40±0.7
* Stainless sintered roller
Four, M6
Depth: 15 min
* Stainless sintered roller
The only difference in the shape for High-sensitivity and
High-precision Switches is the set position marker plate.
Roller lever R63
Basic
WLCA2-8-N
60 max.
53±1.5
41.5±1.5
40±1.5
17.5×7 dia. *
25.4
13.1
R63
Two, M3.5
14.7
Adjustable range:
25 to 89
25.4
58.7±0.2
5
(4.9)
21.6
(15.1)
30.2±0.2
JIS B 0202 G½
40±0.7
25.4
M5
Allen-head
bolt
68.7
Three, M4
5
(4.9)
12.7
Four, 5.2 dia. holes
14.7
58.7±0.2
41.5±1.5
25.4
13.1
Two, M3.5
12.7
M5
Allen-head bolt
Four, 5.2 dia.
holes
(150)
Adjustable roller lever
Basic
High-sensitivity
WLCA12-N
WLG12-N
WLCA12-2-N
67 max.
17.5×7 dia. *
60±1.5
WLCA12-2N-N
29.2±1.2
42 max.
53.2±0.8
Four, M6
Depth: 15 min
68.7
Three, M4
(15.1)
30.2±0.2
40±0.7
JIS B 0202 G½
21.6
29.2±1.2
42 max.
65.2±0.8
Four, M6
Depth: 15 min
* Stainless sintered roller
* Stainless sintered roller
Only the external appearance of the set position
indicator plate varies on high-sensitivity models.
Note: Unless otherwise indicated, a tolerance of ±0.4 mm applies to all dimensions.
Model
Operating characteristics
Operating force
Release force
Pretravel
Overtravel
Movement Differential
OF
RF
PT
OT
MD
max.
min.
min.
max.
Model
Operating characteristics
Operating force
Release force
Pretravel
Overtravel
Movement Differential
OF
RF
PT
OT
MD
max.
min.
min.
max.
WLCA2-N
WLCA2-2-N
WLCA2-2N-N
WLG2-N
WLCA2-7-N
WLCA2-8-N
WLGCA2-N
13.34 N
1.18 N
15±5°
70°
12°
13.34 N
1.18 N
25±5°
60°
16°
13.34 N
1.18 N
20° max.
70°
10°
13.34 N
1.18 N
+2°
10° −1°
80°
7°
10.2 N
0.9 N
15±5°
70°
12°
8.04 N
0.71 N
15±5°
70°
12°
13.34 N
1.18 N
+2°
5° 0°
85°
3°
WLCA12-N *1
WLCA12-2-N
*1
WLG12-2N-N *1
WLG12-N *1
13.34 N
1.18 N
15±5°
70°
12°
13.34 N
1.18 N
25±5°
60°
16°
13.34 N
1.18 N
20° max.
70°
10°
13.34 N
1.18 N
+2°
10° −1°
80°
7°
*1. The operating characteristics for WLCA12-N, WLCA12-2-N, WLCA12-2N-N, and WLG12-N are measured at the lever length of 38 mm.
32
WL-N/WLM-N
Switches with Roller Lever Actuators
Basic, High-sensitivity, and Protective Switches
Adjustable rod lever 25 to 140 mm
Basic
High-sensitivity
WLCL-N
WLGL-N
WLCL-2-N
9
WLCL-2N-N
Adjustable rod lever
Basic
WLCAL4-N
67 max.
8
3.2 dia. *
55 max.
46±1.5
3±0.2
dia.
(length:160) *
Adjustable range:
25 to 140
Two, M3.5
M8
Allen-head
set screw
41.5±1.5
25.4
13.1
12.7
Adjustable range:
350 to 380
12.7
Four, 5.2 dia.
holes
65
25.4
14.7
68.7
58.7±0.2
5
25.4
M5
Allen-head
set screw
Four, 5.2 dia.
holes
14.7
M5
Allen-head
set screw
Three, M4
58.7±0.2
54.5±1.5
12.8
41.5±1.5
25.4
13.1
68.7
Three, M4
5
(4.9)
(15.1)
30.2±0.2
40±0.7
JIS B 0202 G½
(4.9)
21.6 Four, M6
Depth: 15 min.
29.2±1.2
42 max.
JIS B 0202 G½
(15.1)
30.2±0.2
40±0.7
21.6
29.2±1.2
42 max.
Four, M6
Depth: 15 min.
* Stainless steel rod
* Stainless steel rod
Only the external appearance of the set position
indicator plate varies on high-sensitivity models.
Rod spring lever
Basic
WLCAL5-N
Fork lever lock
Protective Switches
WLCA32-41-N
WLCA32-42-N
WLCA32-43-N
WLCA32-44-N
67max.
7.5
2.3 dia. *
The WLCA32-41-N is shown in the following
diagram.
428.5±2
54.5±1.5
Two, 17.5×7 dia. *
90°±3°
41.5±1.5
25.4
65
R38
Two, M3.5
13.1
12.7
14.7
Four, 5.2
dia. holes
11
14.7
34.1
M5 Allen-head
set screw
Four, 5.2 dia.
holes
Three, M4
(125)
25.4
M5
Allen-head
bolt
62.5 max.
56.4±3.5
42.8±3.5
25.4 13.1
12.7
58.7±0.2
68.7
68.7
58.7±0.2
Three, M4
5 (15.1)
21.6
JIS B 0202 G½
(4.9)
5
(4.9)
(15.1)
30.2±0.2
40±0.7
JIS B 0202 G½
21.6
29.2±1.2
42 max.
Four, M6
Depth: 15 min.
30.2±0.2
29.2±1.2
40±0.7
42 max.
4-M6
Four, M6
Depth: 15 min.
* Plastic Roller
(The WLCA32-041-N to WLCA32-044-N have stainless steel rollers.)
* Piano wire
Note: 1. Unless otherwise indicated, a tolerance of ±0.4 mm applies to all dimensions.
Model
Operating characteristics
Operating force
Release force
Pretravel
Overtravel
Movement Differential
OF
RF
PT
OT
MD
max.
min.
min.
max.
WLCL-N *1
WLCL-2-N *1
WLCL-2N-N *1
WLGL-N *1
WLCAL4-N *2
WLCAL5-N
1.39 N
0.27 N
15±5°
70°
12°
1.39 N
0.27 N
25±5°
60°
16°
1.39 N
0.27 N
20° max.
70°
10°
2.84 N
0.25 N
+2°
10° −1°
80°
7°
0.98 N
0.15 N
15±5°
70°
12°
0.9 N
0.09 N
15±5°
70°
12°
Note: The actuator on the WLCAL4-N and WLCAL5-N is heavy, which may result in resetting problems depending on the direction the Switch is
mounted. Mount the Switch so that the actuator is facing downwards to prevent this problem from occurring.
*1. The operating characteristics for WLCL-N, WLCL-2-N, WLCL-2N-N, and WLGL-N are measured at the lever length of 140 mm.
*2. The operating characteristics of WLCAL4-N are measured at a rod length of 380 mm.
Model
Operating characteristics
Force necessary to reverse the direction of the lever
Movement until the lever reverses
Movement until switch operation
Movement after switch operation
max.
max.
min.
WLCA32-41 to 44-N
11.77 N
50±5°
55°
35°
33
WL-N/WLM-N
Switches with Plunger Actuators
Basic Switches
Sealed Top Plunger
WLD18-N
10 dia.
13.1
R1 *
12.9
PT
Horizontal Plunger
WLSD-N
13.1
Two, M3.5
12.7
25 dia. *2 R1
Two, M3.5
OP
27.5
17.8
9.3 dia. *1
(96.2)
Four, 5.2 dia. holes
58.7±0.2
Four, 5.2 dia. holes
58.7±0.2
68.7
68.7
Three, M4
Three, M4
5
(4.9)
* Stainless steel plunger
OP
46.6±0.8
PT
25.4
(15.1)
30.2±0.2
JIS B 0202 G½
40±0.7
Sealed Top-roller Plunger
WLD28-N
PT
21.6
29.2±1.2
42 max.
Four, M6
Depth: 15 min
(4.9)
(15.1)
30.2±0.2
JIS B 0202 G½
40±0.7
13.1
14.3 dia.×5 *
5
*1. Stainless steel plunger
*2. Cosmetic nuts
12.9
Horizontal-roller Plunger
WLSD2-N
25.4
PT
Two, M3.5
21.6
29.2±1.2
42 max.
Four, M6
Depth: 15 min
OP
55.7±0.8
13.1
12.7
25 dia. *2
Two, M3.5
OP
27.5
17.8
17 dia.×4.6 *1
(96.2)
Four, 5.2 dia. holes
58.7±0.2
Four, 5.2 dia. holes
58.7±0.2
68.7
68.7
Three, M4
Three, M4
5
(4.9)
*Stainless sintered roller
(15.1)
30.2±0.2
JIS B 0202 G½
40±0.7
Sealed Top-ball Plunger
15.5 dia.
WLD38-N
PT
1/2" dia.
21.6
29.2±1.2
42 max.
5
Four, M6
Depth: 15 min
(4.9)
(15.1)
30.2±0.2
JIS B 0202 G½
40±0.7
13.1
12.9
*
*1. Stainless sintered roller
*2. Cosmetic nuts
Horizontal-ball Plunger
WLSD3-N
25.4
PT
Two, M3.5
21.6
29.2±1.2
42 max.
OP
46.6±0.8
25 dia. *2
Four, M6
Depth: 15 min
13.1
12.7
Two, M3.5
OP
15.5 dia.
27.5
17.8
1/2" dia. *1
(96.2)
Four, 5.2 dia. holes
58.7±0.2
Four, 5.2 dia. holes
58.7±0.2
68.7
68.7
Three, M4
Three, M4
5
* Stainless steel ball
(4.9)
(15.1)
30.2±0.2
40±0.7
JIS B0202 G½
21.6
29.2±1.2
42 max.
Four, M6
Depth: 15 min
* 1. Stainless steel ball
* 2. Cosmetic nuts
5
(4.9)
(15.1)
30.2±0.2
JIS B0202 G½
40±0.7
21.6
29.2±1.2
42 max.
Four, M6
Depth: 15 min
Note: Unless otherwise indicated, a tolerance of ±0.4 mm applies to all dimensions.
Model
Operating characteristics
34
WLD18-N
WLD28-N
WLD38-N
WLSD-N
WLSD2-N
WLSD3-N
Operating force
Release force
Pretravel
Overtravel
Movement Differential
OF
RF
PT
OT
MD
max.
min.
max.
min.
max.
26.67 N
8.92 N
1.7 mm
6.4 mm
1 mm
16.67 N
4.41 N
1.7 mm
5.6 mm
1 mm
16.67 N
4.41 N
1.7 mm
5.6 mm
1 mm
40.03 N
8.89 N
2.8 mm
6.4 mm
1 mm
40.03 N
8.89 N
2.8 mm
5.6 mm
1 mm
40.03 N
8.89 N
2.8 mm
4 mm
1 mm
Operating position
Total travel position
OP
TTP
max.
34±0.8 mm
29.5 mm
44±0.8 mm
39.5 mm
44.5±0.8 mm
41 mm
40.6±0.8 mm
—
54.2±0.8 mm
—
54.1±0.8 mm
—
WL-N/WLM-N
Switches with Flexible Rod Actuators
Basic Switches
Coil Spring
WLNJ-N
Coil Spring (Multi-wire)
WLNJ-30-N
*1
PT
*1
6.5 dia.
PT
*3
4.8 dia.
*3
*2
*2
(107)
(107)
140±2.5
140±2.5
13.1
12.9
13.1
12.9
Two, M3.5
Two, M3.5
33.7±0.8
33.7±0.8
Four, 5.2 dia. holes
Four, 5.2 dia. holes
58.7±0.2
68.7
58.7±0.2
68.7
Three, M4
Three, M4
5
(4.9)
(15.1)
30.2±0.2
JIS B 0202 G½
40±0.7
21.6
29.2±1.2
42 max.
Four, M6
Depth: 15 min
(4.9)
(15.1)
30.2±0.2
21.6
29.2±1.2
42 max.
Four, M6
Depth: 15 min
*1. Do not operate the Switch in the direction of the axial center.
*2. Piano wire coil spring.
*3. The range for operation is 1/3rd of the overall spring length from the end of the spring.
Steel Wire
WLNJ-S2-N
*1
PT
JIS B 0202 G½
40±0.7
*1. Do not operate the Switch in the direction of the axial center.
*2. Stainless steel coil spring.
*3. The range for operation is 1/3rd of the overall spring length from the end of the spring.
Resin Rod
WLNJ-2-N
5
*1
*3
1 dia
PT
8 dia.
*3
*2
(95.4)
(159)
140±2.5
13.1
12.9
26 dia.
*2
193±2.5
13.1
12.9
Two, M3.5
44.6±0.8
Two, M3.5
33.7±0.8
Four, 5.2 dia. holes
58.7±0.2
Four, 5.2 dia. holes
68.7
58.7±0.2
Three, M4
5
(4.9)
(15.1)
30.2±0.2
JIS B0202 G½
40±0.7
68.7
Three, M4
21.6
29.2±1.2
42 max.
Four, M6
Depth: 15 min
5
(4.9)
(15.1)
30.2±0.2
JIS B 0202 G½
40±0.7
*1. Do not operate the Switch in the direction of the axial center.
*2. Polyamide Resin Rod
*3. The range for operation is 1/3rd of the overall rod length from the end of the rod.
21.6
29.2±1.2
42 max.
Four, M6
Depth: 15 min
*1. Do not operate the Switch in the direction of the axial center.
*2. Stainless steel wire.
*3. The range for operation is 1/3rd of the overall wire length from the end of the wire.
Note: Unless otherwise indicated, a tolerance of ±0.4 mm applies to all dimensions.
Model
Operating characteristics
Operating force
Pretravel
OF
PT
Max.
WLNJ-N
WLNJ-30-N
WLNJ-2-N
WLNJ-S2-N
1.47 N
20±10 mm
1.47 N
20±10 mm
1.47 N
40±20 mm
0.28 N
40±20 mm
* These values are for the top end of the spring, rod, or wire.
35
WL-N/WLM-N
Sensor I/O connector Switches
(For details about applicable cables, refer to Connecting Sensor I/O Connectors Cable and Socket on page 16.)
Switches with Roller Lever Actuators
Switches with Direct-wired Connectors
Basic Switches
WLCA2-LDK13-N
High-sensitivity Switches
WLG2-LDK13-N
High-precision Switches
WLGCA2-LDK13-N
Switches with Pre-wired Connectors
Basic Switches
WLCA2-LD-M1J-N
High-sensitivity Switches
WLG2-LD-M1J-N
High-precision Switches
WLGCA2-LD-M1J-N
17.5×7 dia. *
60 max.
53±1.5
41.5±1.5
40±1.5
25.4
13.1
12.7
17.5×7 dia. *
Two, M3.5
Two, M3.5
R38
M5
Allen-head bolt
14.7
Four, 5.2 dia. holes
M5
Allen-head
bolt
(125)
12.7
Four, 5.2 dia. holes
25.4
R38
14.7
60 max.
53±1.5
41.5±1.5
40±1.5
25.4
13.1
(125)
25.4
58.7±0.2
68.7
Three, M4
68.7
58.7±0.2
5
Three, M4
(4.9)
(15.1)
5
12.5
(4.9)
(15.1)
30.2±0.2
40±0.7
29.2±1.2
42 max.
53.2±0.8
M12×1
Four, M6
Depth: 15 min
SC-1M
Four, M6
Depth: 15 min.
300 +100
−50
XS2H-D421
* Stainless sintered roller
29.2±1.2
30.2±0.2
40±0.7
42 max.
53.2±0.8
* Stainless sintered roller
The only difference in the shape for High-sensitivity and
High-precision Switches is the set position marker plate.
The only difference in the shape for High-sensitivity and
High-precision Switches is the set position marker plate.
Note: 1. Unless otherwise indicated, a tolerance of ±0.4 mm applies to all dimensions.
2. The following diagrams are for a indicator-equipped models.
Model
Operating force
Release force
Pretravel
Overtravel
Movement Differential
OF
RF
PT
OT
MD
High-sensitivity
Switches
Basic Switches
Operating characteristics
max.
min.
13.34 N
1.18 N
15±5°
70°
12°
min.
max.
High-precision
Switches
13.34 N
1.18 N
+2°
10° −1°
80°
7°
13.34 N
1.18 N
+2°
5° 0°
80°
3°
Operation indicator Switches
Roller lever
WLCA2-LD-N
WLCA2-LE-N
17.5×7 dia. *
Two, M3.5
R38
60 max.
53±1.5
41.5±1.5
40±1.5
25.4
13.1
12.7
Four, 5.2 dia. holes
25.4
(125)
14.7
M5
Allen-head bolt
58.7±0.2
68.7
Three, M4
5
21.6
(4.9)
(15.1)
JIS B 0202 G½
30.2±0.2
40±0.7
* Stainless sintered roller
29.2±1.5 Four, M6
42 max. Depth: 15 min
53.2±0.8
Operating force
Release force
Pretravel
Overtravel
Movement Differential
Note: 1. Unless otherwise indicated, a tolerance of ±0.4 mm applies to all dimensions.
36
Model
WLCA2-LD-N
WLCA2-LE-N
max.
min.
13.34 N
1.18 N
15±5°
70°
12°
Operating characteristics
OF
RF
PT
OT
MD
min.
max.
WL-N/WLM-N
Spatter-prevention Switches
Switches with Roller Lever Actuators
Switches with Screw Terminals
Basic Switches
WLCA2-@S-N
High-sensitivity Switches
WLG2-@S-N
High-precision Switches
17.5×7 dia. *
WLGCA2-@S-N
Switches with Pre-wired Connectors
WLCA2-@S-M1J-N
60 max.
53±1.5
41.5±1.5
40±1.5
25.4
13.1
12.7
Two, M3.5
R38
Two, M3.5
R38
12.7
Four, 5.2 dia. holes
25.4
M5
Allen-head bolt
14.7
(125)
Four, 5.2 dia. holes
25.4
(125)
60 max.
53±1.5
41.5±1.5
40±1.5
25.4
13.1
17.5×7 dia. *
14.7
M5
Allen-head bolt
Fluorine
resin cap
Three, M4
58.7±0.2
58.7±0.2
Three, M4
Fluorine
resin cap
68.7
5
68.7
(4.9)
(15.1)
Four, M6
Depth: 15 min
SC-1M
5
(4.9)
(15.1)
30.2±0.2
40±0.7
21.6
29.2±1.2
42 max.
53.2±0.8
JIS B 0202 G½
300 +100
−50
Four, M6
Depth: 15 min
XS2H-D421
* Stainless sintered roller
29.2±1.2
30.2±0.2
40±0.7
The only difference in the shape for High-sensitivity and
High-precision Switches is the set position marker plate.
42 max.
53.2±0.8
* Stainless sintered roller
Switches with Sealed Top-roller Plungers
Switches with Screw Terminals
WLD28-@S-N
Switches with Pre-wired Connectors
WLD28-@S-M1J-N
PT
14.3 dia.×5 *
PT
13.1
12.9
Rubber cap
(fluorine rubber)
Rubber cap
(fluorine rubber)
14.3 dia.×5 *
13.1
12.9
Two, M3.5
OP
Two, M3.5
OP
Four, 5.2 dia. holes
58.7±0.2
68.7
Three, M4
Four, 5.2 dia. holes
58.7±0.2
68.7
5
Three, M4
Four, M6
Depth: 15 min
SC-1M
5
(15.1)
21.6
JIS B 0202 G½
(4.9)
30.2±0.2
29.2±1.2
40±0.7
42 max.
Four, M6
Depth: 15 min
300
+100
−50
XS2H-D421
*Stainless sintered roller
(15.1)
29.2±1.2
(4.9)
30.2±0.2
42 max.
40±0.7
*Stainless sintered roller
Note: 1. Unless otherwise indicated, a tolerance of ±0.4 mm applies to all dimensions.
2. The above diagrams are for Indicator-equipped Switches.
Actuator
Operating characteristics
Operating force
Release force
Pretravel
Overtravel
Movement Differential
OF
RF
PT
OT
MD
max.
min.
Operating position
Total travel position
OT
TTP max.
min.
max.
Switches with Roller Lever Actuators
Switches with Sealed Toproller Plungers
Basic Switches
High-sensitivity
Switches
High-precision
Switches
13.34 N
1.18 N
15±5°
70°
12°
13.34 N
1.18 N
+2°
10° −1°
80°
7°
13.34 N
1.18 N
+2°
5° 0°
80°
3°
16.67 N
4.41 N
Max.1.7 mm
5.6 mm
1 mm
—
—
—
—
—
—
44±0.8 mm
39.5 mm
37
WL-N/WLM-N
Long-life Switches
Switches with Roller Lever Actuators
Switches with Screw Terminals
Basic Switches
WLMCA2-LD-N
High-sensitivity Switches
WLMG2-LD-N
High-precision Switches
WLMGCA2-LD-N
60 max.
53±1.5
41.5±1.5
40±1.5
25.4
17.5 dia.×7 *
Switches with Direct-wired Connectors
Basic Switches
WLMCA2-LDK13-N
High-sensitivity Switches
WLMG2-LDK13-N
High-precision Switches
WLMGCA2-LDK13-N
17.5 dia.×7 *
13.1
12.7
Two, M3.5
R38
14.7
25.4
Four, 5.2 dia. holes
14.7
M5 Allen-head bolt
Fluorine resin cap
68.7
58.7±0.2
68.7
Three, M4
Three, M4
21.6
(15.1)
Four, M6
Depth: 15 min
(4.9)
30.2±0.2
5
12.5
(15.1)
29.2±1.2
JIS B 0202 G½
29.2±1.2
30.2±0.2
53.2±0.8
40±0.7
*Stainless sintered roller
Switches with Pre-wired Connectors
Basic Switches
WLMCA2-LD-M1J-N
High-sensitivity Switches
WLMG2-LD-M1J-N
High-precision Switches
WLMGCA2-LD-M1J-N 17.5 dia.×7 *
60 max.
53±1.5
41.5±1.5
40±1.5
25.4
The only difference in the shape for High-sensitivity and
High-precision Switches is the set position marker plate.
13.1
12.7
Two, M3.5
Four, 5.2 dia. holes
25.4
M5 Allen-head bolt
Fluorine resin cap
58.7±0.2
68.7
Three, M4
5
Four, M6
Depth: 15 min
SC-1M
300
+100
−50
XS2H-D421
(15.1)
29.2±1.2
(4.9)
42 max.
30.2±0.2
40±0.7
53.2±0.8
*Stainless sintered roller
The only difference in the shape for High-sensitivity and
High-precision Switches is the set position marker plate.
Note: 1. Unless otherwise indicated, a tolerance of ±0.4 mm applies to all dimensions.
2. The above diagrams are for Indicator-equipped Switches.
Actuator
Operating characteristics
Operating force
Release force
Pretravel
Overtravel
Movement Differential
38
OF
RF
PT
OT
MD
max.
min.
min.
max.
42 max.
53.2±0.8
*Stainless sintered roller
The only difference in the shape for High-sensitivity and
High-precision Switches is the set position marker plate.
14.7
Four, M6
Depth: 15 min
M12×1
(4.9)
42 max.
40±0.7
R38
25.4
M5 Allen-head bolt
Fluorine resin cap
58.7±0.2
5
13.1
12.7
Two, M3.5
R38
Four, 5.2 dia. holes
60 max.
53±1.5
41.5±1.5
40±1.5
25.4
Switches with Roller Lever Actuators
Basic Switches
High-sensitivity
Switches
High-precision
Switches
13.34 N
1.18 N
15±5°
70°
12°
13.34 N
1.18 N
+2°
10° −1°
80°
7°
13.34 N
1.18 N
+2°
5° 0°
80°
3°
WL-N/WLM-N
Actuators (Levers Only)
Lever: Only rotating lever models are illustrated.
WL-1A100
Standard Lever
WL-1A115
Resin Roller
17.9
17.5 dia. × 7,
sintered stainless steel roller
7.3-dia.
mounting
holes
12.6
WL-1A105
Double Nuts
7.3-dia.
mounting
holes
17.9
7.3-dia.
mounting
holes
12.6
Two, M5
Allenhead nut
11.4
and arm set screw
38
17.9
7.3-dia.
mounting
holes
54.8
7.3-dia.
mounting 16
holes
24.9±0.8
19.7±0.8
17.5 dia. × 7,
sintered stainless steel roller
7.3-dia.
mounting
holes
63
M5
Allen-head bolt 11.4
Adjustable lever:
stainless steel
WL-2A107
Double Nuts
24.9±0.8
19.7±0.8
17.5 dia. (length: 7)
resin roller
Adjustable lever:
stainless steel
Adjustable
range:
25 to 89
105.75
17.5 dia. × 7,
24.9±0.8
sintered stainless M5
steel roller
Allen-head 19.7±0.8
bolt
Adjustable lever:
stainless steel
Adjustable
range:
28 to 88
105.75
7.3-dia.
mounting
holes
7.3-dia.
mounting
holes
M5
Allen-head
bolt
12
16
12
16
12
16
79.8
M5
Allen-head bolt 11.4
17.5 dia. (length: 7)
resin roller
Adjustable lever:
stainless steel
24.9±0.8
M5
Allen-head 19.7±0.8
bolt
23
23
Adjustable
range:
25 to 140
105.75
7.3-dia.
mounting
holes
7.3-dia.
mounting
holes
M5
Allen-head
bolt
12.6
WL-2A108
Resin Roller
23
23
Adjustable
range:
25 to 89
17.9
50 66.8
16
WL-2A111
Resin Roller
M5
Allen-head bolt 11.4
17.5 dia. × 7,
sintered stainless steel roller
25.7
16.6
16
WL-2A100
23.6
WL-1A300
Lever Length: 63
17.5 dia. × 15,
sintered stainless steel roller
12.6
40.2±0.8
54.8
38
M5
Allen-head bolt 11.4
16
M5
Allen-head bolt 11.4
16
12.1
WL-1A200
Lever Length: 50
Roller Width: 15
17.5 dia. (length: 7)
stainless steel roller
7.3-dia.
mounting
holes
38 54.8
17.5 dia. (length: 30)
Nylon roller
16.9
38 54.8
M5
Allen-head bolt 11.4
WL-1A103S
Spatter
17.5 dia. × 7,
sintered stainless steel roller
16
16
WL-1A118
Nylon Roller:
Roller Width: 30 mm
17 dia. (length: 6)
bearing roller
12.6
38 54.8
M5
Allen-head bolt 11.4
16
17.9
17.5 dia. (length: 7)
resin roller
7.3-dia.
mounting
holes
38 54.8
WL-1A400
Bearing Roller
155.75
Two, M5 Allen-head nut
and arm set screw
6.2
(15.8)
WL-2A122
WL-2A106
17.5 dia. × 7,
M5
sintered stainless
Allen-head
steel roller
bolt
Adjustable lever:
stainless steel
24.9±0.8
19.7±0.8
23
9.1
24.7±0.8
19.5±0.8
17.5 dia. × 7,
sintered stainless
steel roller
24.9±0.8
19.7±0.8
50 dia. (length: 6)
Nylon roller
3
Adjustable lever:
stainless steel
23
Adjustable
range:
25 to 89
(10)
R89.5
(10)
105.75
155.75
7.3-dia.
mounting
holes
15.9
* Can be installed
on the rear side.
Adjustable
from 42 to 89
Three, 5.3 +0.2
0
dia. holes
7.3 dia.
mounting holes
(112)
M5
Allen-head
bolt
16
20
6.2
24.9±0.8
19.7±0.8
17.5 dia. × 7,
sintered stainless
steel roller
WL-2A104
(21.8)
Adjustable
range:
25 to 140
7.3-dia.
mounting
holes
WL-2A130
7.3-dia.
mounting
holes
M5
Allen-head bolt
23
20
M5
Allen-head
bolt
12
16
23
(15.8)
Note: 1. Unless otherwise indicated, a tolerance of ±0.4 mm applies to all dimensions.
Lever: Only rotating lever models are illustrated.
39
WL-N/WLM-N
WL-2A110
WL-2A105
WL-1A106
WL-1A110
34.2
34.5
50 dia. (length: 15)
Nylon roller
24.2
49 dia. rubber roller
Material: NBR
24.4
50 dia. (length: 6)
Nylon roller
6
35 dia. (length: 6)
Nylon roller
20.1±0.8
20.1±0.8
R38
Adjustable
from 41 to
78.5
23
122
M5
Allen-head
bolt
7.3-dia.
mounting
holes
R38
23
Adjustable
from 41 to
89
M5
Allen-head
bolt
16
M5
Allen-head
bolt
7.3-dia.
mounting
holes
7.3 dia.
mounting
holes
16
11.5
11.5
M5
Allen-head
bolt
7.3-dia.
mounting
holes
16
16
WL-4A100
WL-4A201
9
9
3-dia. stainless
steel rod
7.3-dia. mounting
holes
M5
Allen-head
bolt
Adjustable
from
25 to 140
160
WL-3A100
3.2-dia.
stainless
steel rod
2-dia. stainless
steel for spring
13
Adjustable
from 270 to
290
Adjustable
from 350
to 380
7.3-dia.
mounting holes
M8
Allen-head
set screw
3.2-dia.
stainless steel rod
Adjustable
from 350
to 380
8
400±2
M5
Allen-head
bolt
19
WL-3A106
Double Nut
400±2
Actuator's
center of
rotation
M8
Allen-head
set screw
8
M5
Allen-head
bolt
11 65±2
7.5
6
11 65±2
7.5
6
11
7.3-dia.
mounting 12.8
holes
11
WL-3A108
WL-3A200
WL-3A203
2.3-dia.
operation rod
3.2-dia.
stainless steel rod
M5
13.4
Allen-head
bolt
25.5 max.
7.3-dia.
mounting
12.8
holes
9
8 dia.
Cap
Adjustable
up to 141
417.5±2
8
437.5±2
450±4
680±0.4
Adhesive
7.3-dia.
mounting 12.8
holes
M5
Allen-head
bolt
7.3-dia.
mounting
holes
7.5
25.5 max.
WL-2A129
15.8
Marking
(95)
11
7.5
6
13.4
WL-5A101
6.7
17.7
12.4
84
95.3
(108)
7.3 dia.
7.3 dia.
mounting
hole
10
15.9
20
M5
Allen-head
bolt
22.1
13
24.6 max.
WL-5A105
Two, 17.5 dia. × 7,
sintered stainless steel rollers
Two, 17.5 dia. × 7,
sintered stainless steel rollers
17.7 6.7
12.4
1.3
11
WL-5A100 has a plastic roller
7.3 dia.
R38
54.8
M5 Allen-head
bolt
11
WL-5A102 has a plastic roller
Note: 1. Unless otherwise indicated, a tolerance of ±0.4 mm applies to all dimensions.
2. When using the adjustable roller (rod) lever, make sure that the lever is facing downwards.
Use caution, as telegraphing (the Switch turns ON and OFF repeatedly due to inertia) may occur.
40
17.7
12.4
90°
7.3 dia.
R38
54.8
M5 Allen-head
bolt
10
11.3
11
90°
90°
Three, 5.2
dia. holes
7.3-dia.
M5
mounting 7.5 Allen-head
holes
bolt
WL-5A103
1.3
(18.5)
M8
Allen-head
set screw
11
7.5
6
M5
13
Allen-head
bolt
24.6 max.
Two, 17.5 dia. × 7,
sintered stainless steel rollers
3
R8
19
12.5
dia.
max.
2.3 dia.
rod
(95)
11 65±2
7.5
6
4-dia. stainless
steel rod
7.3-dia.
mounting holes
M5
Allen-head
bolt
160±1.5
470±4
12.5 dia. max.
13.4
25.5 max.
WL-4A112
50
Adjustable
from 650
to 660
Two, M5
Allenhead
nut and arm
set screw
R38
54.8
M5 Allen-head
bolt
11
WL-5A104 has a plastic roller
WL-N/WLM-N
Model Replacement Table
WL
WL-N
WL
WL-N
WL
WL-N
WLCA2
WLCA2-N
WLSD
WLSD-N
WLHAL5-LE
WLCAL5-LE-N
WL01CA2
WLCA2-N
WL01SD
WLSD-N
WLHAL5-LD
WLCAL5-LD-N
WLH2
WLCA2-N
WLSD2
WLSD2-N
WLCA32-41LE
WLCA32-41LE-N
WL01H2
WLCA2-N
WL01SD2
WLSD2-N
WLCA32-41LD
WLCA32-41LD-N
WLG2
WLG2-N
WLSD3
WLSD3-N
WLCA32-42LE
WLCA32-42LE-N
WL01G2
WLG2-N
WL01SD3
WLSD3-N
WLCA32-43LE
WLCA32-43LE-N
WLCA2-2
WLCA2-2-N
WLNJ
WLNJ-N
WLCA32-43LD
WLCA32-43LD-N
WL01CA2-2
WLCA2-2-N
WL01NJ
WLNJ-N
WLD-LE
WLD18-LE-N
WLCA2-2N
WLCA2-2N-N
WLNJ-30
WLNJ-30-N
WLD-LD
WLD18-LD-N
WL01CA2-2N
WLCA2-2N-N
WL01NJ-30
WLNJ-30-N
WLD2-LE
WLD28-LE-N
WLGCA2
WLGCA2-N
WLNJ-2
WLNJ-2-N
WLD2-LD
WLD28-LD-N
WL01GCA2
WLGCA2-N
WL01NJ-2
WLNJ-2-N
WLD3-LE
WLD38-LE-N
WLCA2-7
WLCA2-7-N
WLNJ-S2
WLNJ-S2-N
WLD3-LD
WLD38-LD-N
WL01CA2-7
WLCA2-7-N
WL01NJ-S2
WLNJ-S2-N
WLD28-LE
WLD28-LE-N
WLCA2-8
WLCA2-8-N
WLCA2-LE
WLCA2-LE-N
WLD28-LD
WLD28-LD-N
WL01CA2-8
WLCA2-8-N
WLCA2-LD
WLCA2-LD-N
WLSD-LE
WLSD-LE-N
WLCA12
WLCA12-N
WLH2-LE
WLCA2-LE-N
WLSD-LD
WLSD-LD-N
WL01CA12
WLCA12-N
WLH2-LD
WLCA2-LD-N
WLSD2-LE
WLSD2-LE-N
WLH12
WLCA12-N
WLG2-LE
WLG2-LE-N
WLSD2-LD
WLSD2-LD-N
WL01H12
WLCA12-N
WLG2-LD
WLG2-LD-N
WLSD3-LE
WLSD3-LE-N
WLG12
WLG12-N
WLCA2-2LE
WLCA2-2LE-N
WLSD3-LD
WLSD3-LD-N
WL01G12
WLG12-N
WLCA2-2LD
WLCA2-2LD-N
WLNJ-LE
WLNJ-LE-N
WLCA12-2
WLCA12-2-N
WLCA2-2NLE
WLCA2-2NLE-N
WLNJ-LD
WLNJ-LD-N
WL01CA12-2
WLCA12-2-N
WLCA2-2NLD
WLCA2-2NLD-N
WLNJ-30LE
WLNJ-30LE-N
WLCA12-2N
WLCA12-2N-N
WLGCA2-LE
WLGCA2-LE-N
WLNJ-30LD
WLNJ-30LD-N
WL01CA12-2N
WLCA12-2N-N
WLGCA2-LD
WLGCA2-LD-N
WLNJ-2LE
WLNJ-2LE-N
WLCL
WLCL-N
WLCA2-7LE
WLCA2-7LE-N
WLNJ-2LD
WLNJ-2LD-N
WL01CL
WLCL-N
WLCA2-7LD
WLCA2-7LD-N
WLNJ-S2LE
WLNJ-S2LE-N
WLHL
WLCL-N
WLCA2-8LE
WLCA2-8LE-N
WLNJ-S2LD
WLNJ-S2LD-N
WL01HL
WLCL-N
WLCA2-8LD
WLCA2-8LD-N
WLCA2-LDK13
WLCA2-LDK13-N
WLGL
WLGL-N
WLCA12-LE
WLCA12-LE-N
WLCA2-55LDK13
WLCA2-55LDK13-N
WL01GL
WLGL-N
WLCA12-LD
WLCA12-LD-N
WLCA2-LDK43
WLCA2-LDK43-N
WLCL-2
WLCL-2-N
WLH12-LE
WLCA12-LE-N
WLCA2-55LDK43
WLCA2-55LDK43-N
WLCL-2N
WLCL-2N-N
WLH12-LD
WLCA12-LD-N
WLD2-LDK13
WLD28-LDK13-N
WL01CL-2N
WLCL-2N-N
WLG12-LE
WLG12-LE-N
WLD2-55LDK13
WLD28-55LDK13-N
WLHAL4
WLCAL4-N
WLG12-LD
WLG12-LD-N
WLD2-LDK43
WLD28-LDK43-N
WLHAL5
WLCAL5-N
WLCA12-2LE
WLCA12-2LE-N
WLD2-55LDK43
WLD28-55LDK43-N
WLCA32-41
WLCA32-41-N
WLCA12-2LD
WLCA12-2LD-N
WLH2-LDK13
WLCA2-LDK13-N
WL01CA32-41
WLCA32-41-N
WLCA12-2NLE
WLCA12-2NLE-N
WLH2-55LDK13
WLCA2-55LDK13-N
WLCA32-42
WLCA32-42-N
WLCA12-2NLD
WLCA12-2NLD-N
WLH2-LDK43
WLCA2-LDK43-N
WLCA32-43
WLCA32-43-N
WLCL-LE
WLCL-LE-N
WLH2-55LDK43
WLCA2-55LDK43-N
WL01CA32-43
WLCA32-43-N
WLCL-LD
WLCL-LD-N
WLG2-LDK13
WLG2-LDK13-N
WLCA32-44
WLCA32-44-N
WLHL-LE
WLCL-LE-N
WLG2-55LDK13
WLG2-55LDK13-N
WL01CA32-44
WLCA32-44-N
WLHL-LD
WLCL-LD-N
WLG2-LDK43
WLG2-LDK43-N
WLD
WLD18-N
WLGL-LE
WLGL-LE-N
WLG2-55LDK43
WLG2-55LDK43-N
WL01D
WLD18-N
WLGL-LD
WLGL-LD-N
WLGCA2-LDK13
WLGCA2-LDK13-N
WLD2
WLD28-N
WLCL-2LE
WLCL-2LE-N
WLGCA2-55LDK13
WLGCA2-55LDK13-N
WL01D2
WLD28-N
WLCL-2LD
WLCL-2LD-N
WLGCA2-LDK43
WLGCA2-LDK43-N
WLD3
WLD38-N
WLCL-2NLE
WLCL-2NLE-N
WLGCA2-55LDK43
WLGCA2-55LDK43-N
WL01D3
WLD38-N
WLCL-2NLD
WLCL-2NLD-N
WLCA2-LD-M1J
WLCA2-LD-M1J-N
WLD28
WLD28-N
WLHAL4-LE
WLCAL4-LE-N
WLCA2-55LD-M1J
WLCA2-55LD-M1J-N
WL01D28
WLD28-N
WLHAL4-LD
WLCAL4-LD-N
WLCA2-LD-M1GJ
WLCA2-LD-M1GJ-N
41
WL-N/WLM-N
WL
42
WL-N
WL
WL-N
WL
WL-N
WLCA2-55LD-M1GJ
WLCA2-55LD-M1GJ-N
WLH2-55LE
WLCA2-55LE-N
WLGCA2-139LD3
WLGCA2-139LD3-N
WLCA2-55LD-M1JB
WLCA2-55LD-M1JB-N
WLH2-139
WLCA2-139-N
WLGCA2-140
Ask your OMRON representative.
WLCA2-LD-DGJ03
WLCA2-LD-DGJ-N
WLH2-140
WLCA2-140-N
WLGCA2-140LD2
Ask your OMRON representative.
WLCA2-55LD-DGJ03
WLCA2-55LD-DGJ-N
WLH2-141
WLCA2-141-N
WLGCA2-140LD3
Ask your OMRON representative.
WLCA2-LD-DK1EJ03
WLCA2-LD-DK1EJ-N
WLH2-141LD3
WLCA2-141LD3-N
WLGCA2-141
WLGCA2-141-N
WLCA2-55LD-DK1EJ03
WLCA2-55LD-DK1EJ-N
WLH2-RP60
WLCA2-RP60-N
WLGCA2-141LD3
WLGCA2-141LD3-N
WLD2-LD-M1J
WLD28-LD-M1J-N
WLH2-RP60LD3
WLCA2-RP60LD3-N
WLGCA2-RP60
WLGCA2-RP60-N
WLD2-55LD-M1J
WLD28-55LD-M1J-N
WLH2-TH
WLCA2-TH-N
WLGCA2-RP60LD2
WLGCA2-RP60LD2-N
WLD2-LD-M1GJ
WLD28-LD-M1GJ-N
WLH2-TC
WLCA2-TC-N
WLGCA2-RP60LD3
WLGCA2-RP60LD3-N
WLD2-55LD-M1GJ
WLD28-55LD-M1GJ-N
WLH2-RP
WLCA2-RP-N
WLGCA2-TH
WLGCA2-TH-N
WLD2-55LD-M1JB
WLD28-55LD-M1JB-N
WLH2-P1
WLCA2-P1-N
WLGCA2-TC
WLGCA2-TC-N
WLD2-LD-DGJ03
WLD28-LD-DGJ-N
WLG2-55
WLG2-55-N
WLGCA2-RP
WLGCA2-RP-N
WLD2-LD-DK1EJ03
WLD28-LD-DK1EJ-N
WLG2-55LD
WLG2-55LD-N
WLCA12-55
WLCA12-55-N
WLD2-55LD-DK1EJ03 WLD28-55LD-DK1EJ-N
WLG2-55LE
WLG2-55LE-N
WLCA12-55LD
WLCA12-55LD-N
WLH2-LD-M1J
WLCA2-LD-M1J-N
WLG2-139
WLG2-139-N
WLCA12-55LE
WLCA12-55LE-N
WLH2-LD-M1GJ
WLCA2-LD-M1GJ-N
WLG2-139LD3
WLG2-139LD3-N
WLCA12-139
WLCA12-139-N
WLH2-LD-DGJ03
WLCA2-LD-DGJ-N
WLG2-140
WLG2-140-N
WLCA12-140
WLCA12-140-N
WLG2-LD-M1J
WLG2-LD-M1J-N
WLG2-140LD2
Ask your OMRON representative.
WLCA12-141
WLCA12-141-N
WLG2-LD-M1GJ
WLG2-LD-M1GJ-N
WLG2-140LD3
Ask your OMRON representative.
WLCA12-RP60
WLCA12-RP60-N
WLG2-55LD-M1GJ
WLG2-55LD-M1GJ-N
WLG2-141
WLG2-141-N
WLCA12-TH
WLCA12-TH-N
WLG2-LD-M1JB
WLG2-LD-M1JB-N
WLG2-141LD2
WLG2-141LD2-N
WLCA12-TC
WLCA12-TC-N
WLG2-55LD-M1JB
WLG2-55LD-M1JB-N
WLG2-141LD3
WLG2-141LD3-N
WLCA12-RP
WLCA12-RP-N
WLG2-LD-DGJ03
WLG2-LD-DGJ-N
WLG2-RP60
WLG2-RP60-N
WLCA12-P1
WLCA12-P1-N
WLG2-55LD-DGJ03
WLG2-55LD-DGJ-N
WLG2-RP60LD2
WLG2-RP60LD2-N
WLH12-TH
WLCA12-TH-N
WLG2-LD-DK1EJ03
WLG2-LD-DK1EJ-N
WLG2-RP60LD3
WLG2-RP60LD3-N
WLH12-TC
WLCA12-TC-N
WLG2-55LD-DK1EJ03
WLG2-55LD-DK1EJ-N
WLG2-TH
WLG2-TH-N
WLH12-RP
WLCA12-RP-N
WLGCA2-LD-M1J
WLGCA2-LD-M1J-N
WLG2-TC
WLG2-TC-N
WLH12-P1
WLCA12-P1-N
WLGCA2-55LD-M1J
WLGCA2-55LD-M1J-N
WLG2-RP
WLG2-RP-N
WLG12-TH
WLG12-TH-N
WLGCA2-LD-M1GJ
WLGCA2-LD-M1GJ-N
WLG2-P1
WLG2-P1-N
WLG12-TC
WLG12-TC-N
WLGCA2-55LD-M1JB
WLGCA2-55LD-M1JB-N
WLCA2-255
WLCA2-255-N
WLG12-RP
WLG12-RP-N
WLGCA2-55LD-DGJ03
WLGCA2-55LD-DGJ-N
WLCA2-255LD
WLCA2-255LD-N
WLG12-P1
WLG12-P1-N
WLCA2-55
WLCA2-55-N
WLCA2-255LE
WLCA2-255LE-N
WLCA12-2TH
WLCA12-2TH-N
WLCA2-55LD
WLCA2-55LD-N
WLCA2-2139
WLCA2-2139-N
WLCA12-2TC
WLCA12-2TC-N
WLCA2-55LE
WLCA2-55LE-N
WLCA2-2139LD2
WLCA2-2139LD2-N
WLCA12-2NTH
WLCA12-2NTH-N
WLCA2-139
WLCA2-139-N
WLCA2-2139LD3
WLCA2-2139LD3-N
WLCA12-2NTC
WLCA12-2NTC-N
WLCA2-139LD2
WLCA2-139LD2-N
WLCA2-2RP60
WLCA2-2RP60-N
WLCL-55
WLCL-55-N
WLCA2-139LD3
WLCA2-139LD3-N
WLCA2-2RP60LD2
WLCA2-2RP60LD2-N
WLCL-55LD
WLCL-55LD-N
WLCA2-140
WLCA2-140-N
WLCA2-2RP60LD3
WLCA2-2RP60LD3-N
WLCL-139
WLCL-139-N
WLCA2-140LD2
Ask your OMRON representative.
WLCA2-2TH
WLCA2-2TH-N
WLCL-140
WLCL-140-N
WLCA2-140LD3
Ask your OMRON representative.
WLCA2-2TC
WLCA2-2TC-N
WLCL-RP60
WLCL-RP60-N
WLCA2-141
WLCA2-141-N
WLCA2-2N55
WLCA2-2N55-N
WLCL-TH
WLCL-TH-N
WLCA2-141LD2
WLCA2-141LD2-N
WLCA2-2N55LD
WLCA2-2N55LD-N
WLCL-TC
WLCL-TC-N
WLCA2-141LD3
WLCA2-141LD3-N
WLCA2-2N55LE
WLCA2-2N55LE-N
WLCL-RP
WLCL-RP-N
WLCA2-RP60
WLCA2-RP60-N
WLCA2-2N139
WLCA2-2N139-N
WLCL-P1
WLCL-P1-N
WLCA2-RP60LD2
WLCA2-RP60LD2-N
WLCA2-2N140
WLCA2-2N140-N
WLHL-TH
WLCL-TH-N
WLCA2-RP60LD3
WLCA2-RP60LD3-N
WLCA2-2NTH
WLCA2-2NTH-N
WLHL-TC
WLCL-TC-N
WLCA2-TH
WLCA2-TH-N
WLCA2-2NTC
WLCA2-2NTC-N
WLHL-RP
WLCL-RP-N
WLCA2-TC
WLCA2-TC-N
WLGCA2-55
WLGCA2-55-N
WLHL-P1
WLCL-P1-N
WLCA2-RP
WLCA2-RP-N
WLGCA2-55LD
WLGCA2-55LD-N
WLGL-TH
WLGL-TH-N
WLCA2-P1
WLCA2-P1-N
WLGCA2-55LE
WLGCA2-55LE-N
WLGL-TC
WLGL-TC-N
WLH2-55
WLCA2-55-N
WLGCA2-139
WLGCA2-139-N
WLGL-RP
WLGL-RP-N
WLH2-55LD
WLCA2-55LD-N
WLGCA2-139LD2
WLGCA2-139LD2-N
WLGL-P1
WLGL-P1-N
WL-N/WLM-N
WL
WL-N
WL
WL-N
WL
WL-N
WLCL-2TH
WLCL-2TH-N
WLG2-LEAS
WLG2-LEAS-N
WLRCL
WLCL-2TC
WLCL-2TC-N
WLCA2-LDAS
WLCA2-LDAS-N
WLRG2
WLRG2-N
WLCL-2RP
WLCL-2RP-N
WLH2-LDAS
WLCA2-LDAS-N
WLRCA2-2
WLRCA2-2-N
WLCL-2NTH
WLCL-2NTH-N
WLG2-LDAS
WLG2-LDAS-N
WLRCA2-2N
WLRCA2-2N-N
WLCL-2NTC
WLCL-2NTC-N
WLCA2-LES
WLCA2-LES-N
WLRCA32
WLRCA32-N
WLD2-55
WLD28-55-N
WLH2-LES
WLCA2-LES-N
WLRCA2-LDS
WLRCA2-LDS-N
WLD2-55LD
WLD28-55LD-N
WLG2-LES
WLG2-LES-N
WLRH2-LES
WLRCA2-LES-N
WLD2-55LE
WLD28-55LE-N
WLGCA2-LES
WLGCA2-LES-N
WLRH2-LDS
WLRCA2-LDS-N
WLD2-139
WLD28-139-N
WLCA2-LDS
WLCA2-LDS-N
WLRG2-LDS
WLRG2-LDS-N
WLD2-RP60
WLD28-RP60-N
WLH2-LDS
WLCA2-LDS-N
WLRGCA2-LES
WLRGCA2-LES-N
WLD2-TH
WLD28-TH-N
WLG2-LDS
WLG2-LDS-N
WLD2-TC
WLD28-TC-N
WLGCA2-LDS
WLGCA2-LDS-N
WLD2-RP
WLD28-RP-N
WLD28-LES
WLD28-LES-N
WLD28-55
WLD28-55-N
WLD28-LDS
WLD28-LDS-N
WLD28-55LD
WLD28-55LD-N
WLMCA2-LD
WLMCA2-LD-N
WLD28-55LE
WLD28-55LE-N
WLMCA2-LDK13A
WLMCA2-LDK13A-N
WLD28-139
WLD28-139-N
WLMCA2-LDK13
WLMCA2-LDK13-N
WLD28-140
WLD28-140-N
WLMCA2-LDK43A
WLMCA2-LDK43A-N
WLD28-RP60
WLD28-RP60-N
WLMCA2-LDK43
WLMCA2-LDK43-N
WLD28-TH
WLD28-TH-N
WLMCA2-LD-M1J
WLMCA2-LD-M1J-N
WLD28-RP
WLD28-RP-N
WLMCA2-LD-DGJ03
WLMCA2-LD-DGJ-N
WLSD-55
WLSD-55-N
WLMGCA2-LD
WLMGCA2-LD-N
WLSD-55LD
WLSD-55LD-N
WLMGCA2-LDK13A
WLMGCA2-LDK13A-N
WLSD-139
WLSD-139-N
WLMGCA2-LDK13
WLMGCA2-LDK13-N
WLSD-RP60
WLSD-RP60-N
WLMGCA2-LDK43A
WLMGCA2-LDK43A-N
WLSD-TH
WLSD-TH-N
WLMGCA2-LDK43
WLMGCA2-LDK43-N
WLSD-TC
WLSD-TC-N
WLMGCA2-LD-M1J
WLMGCA2-LD-M1J-N
WLSD-RP
WLSD-RP-N
WLMH2-LD
WLMCA2-LD-N
WLSD2-55
WLSD2-55-N
WLMH2-LDK13A
WLMCA2-LDK13A-N
WLSD2-55LD
WLSD2-55LD-N
WLMH2-LDK13
WLMCA2-LDK13-N
WLSD2-139
WLSD2-139-N
WLMH2-LDK43A
WLMCA2-LDK43A-N
WLSD2-140
WLSD2-140-N
WLMH2-LDK43
WLMCA2-LDK43-N
WLSD2-RP60
WLSD2-RP60-N
WLMH2-LD-M1J
WLMCA2-LD-M1J-N
WLSD2-TH
WLSD2-TH-N
WLMH2-LD-DGJ03
WLMCA2-LD-DGJ-N
WLSD2-TC
WLSD2-TC-N
WLMG2-LD
WLMG2-LD-N
WLSD2-RP
WLSD2-RP-N
WLMG2-LDK13A
WLMG2-LDK13A-N
WLNJ-55
WLNJ-55-N
WLMG2-LDK13
WLMG2-LDK13-N
WLNJ-55LD
WLNJ-55LD-N
WLMG2-LDK43A
Ask your OMRON representative.
WLNJ-139
WLNJ-139-N
WLMG2-LDK43
WLMG2-LDK43-N
WLNJ-140
WLNJ-140-N
WLMG2-LD-M1J
WLMG2-LD-M1J-N
WLNJ-RP60
WLNJ-RP60-N
WLMG2-LD-DGJ03
WLMG2-LD-DGJ-N
WLNJ-TH
WLNJ-TH-N
WLRCA2
WLRCA2-N
WLNJ-TC
WLNJ-TC-N
WLRGCA2
WLRGCA2-N
WLNJ-RP
WLNJ-RP-N
WLRG2
WLRG2-N
WLNJ-255
WLNJ-255-N
WLRH2
WLRCA2-N
WLNJ-255LD-N
WLRCA2-2
WLRCA2-2-N
WLNJ-2140
WLNJ-2140-N
WLRCA2-2N
WLRCA2-2N-N
WLNJ-2RP60
WLNJ-2RP60-N
WLRCA2
WLRCA2-N
WLNJ-2TC
Ask your OMRON representative.
WLRG2
WLRG2-N
WLNJ-2RP
WLNJ-2RP-N
WLRH2
WLRCA2-N
WLCA2-LEAS
WLCA2-LEAS-N
WLRCA2-2
WLRCA2-2-N
WLH2-LEAS
WLCA2-LEAS-N
WLRCA2-2N
WLRCA2-2N-N
WLNJ-255LD
WLRCA2-N
43
WL-N/WLM-N
Safety Precautions
Precautions for Safe Use
• Be sure to ground. If not, there is the possibility that electrical shock
occurs.
• Do not touch charged switch terminals while the switch has carry
current, otherwise there is the possibility that electrical shock
occurs.
• Do not disassemble the limit switch or touch inside of it under
supplying power, otherwise there is the possibility that electrical
shock occurs.
• Do not touch the wire or rod type actuator in order to prevent injury.
• Connect a fuse which has 1.5 to 2 times higher breaking current
than the switch rated current to the switch in series in order to
prevent the switch from short-circuit damage.
On the occasion when using the switch with GB ratings, use a 10A
fuse that complies IEC60269, either type gG.
• The durability of switch is depends on the operating condition.
Be sure to check the condition with actual using condition before
using, and use with the number of times of operating without a
performance problem.
• Do not drop the switch. Otherwise, there is the possibility that the
switch functions may be spoiled.
• Do not connect a Single Limit Switch to two power supplies that are
different in polarity or type.
• Be sure to keep the load current less than the rated value.
Otherwise, there is the possibility that the switch may be damage
and/or burnout.
• Minimum operating load: 5 VDC 1 mA, resistive load, P level
Note: The P level indicates the standard malfunction level at a
reliability level of 60% (λ60).
(JISC5003) λ60 = 0.1 × 10-6 per operation, which indicates an
estimated malfunction of 1 out of every 10,000,000 operations
at a reliability level of 60%.
• Do not use the Switch by itself in atmospheres containing
flammable or explosive gases. Arcs and heating resulting from
switching may cause fire or explosion.
• Be sure to prevent the foreign materials such like a scrapped cable
intrusion in to the switch when wiring. Otherwise, there is the
possibility of spoiling the normal operation.
• Never wire to the wrong terminals.
• Do not store or use the switch with following place.
Where the temperature fluctuates greatly
Where the humidity is very high and condensation may occur.
Where the vibration is too much
Where receiving direct sunshine.
Where receiving salty wind.
• Do not disassemble and/or modify the switch at anytime.
Otherwise, there is the possibility of spoiling the normal operation.
• Do not apply the force such like deformation and/or degeneration
to the switch. Otherwise, there is the possibility that the switch
functions may be spoiled.
44
Precautions for Correct Use
Environment
• Take special care to use where there is fine powder, mud and/or
foreign materials stacking. And check the condition with actual
using condition before using. Then use without a performance
problem.
• This switch is only for indoor use. If it is used in outdoor, it may be
cause of switch failure.
• Do not keep the Switch in locations with corrosive gas, such as
sulfuric gas (H2S or SO2), ammonium gas (NH3), nitric gas (HNO3),
or chlorine gas (Cl2), or high temperature and humidity. Otherwise,
contact failure or corrosion damage may result.
• Seal material may deteriorate if a Switch is used outdoor or where
subject to special cutting oils, solvents, or chemicals. Always
appraise performance under actual application conditions and set
suitable maintenance and replacement periods.
• Install Switches where they will not be directly subject to cutting
chips, dust, or dirt. The Actuator and Switch must also be protected
from the accumulation of cutting chips or sludge.
Not Suitable
Suitable
• Constantly subjecting a Switch to vibration or shock can result in
wear, which can lead to contact interference with contacts,
operation failure, reduced durability, and other problems.
Excessive vibration or shock can lead to false contact operation or
damage. Install Switches in locations not subject to shock and
vibration and in orientations that will not produce resonance.
• The Switches have physical contacts. Using them in environments
containing silicon gas will result in the formation of silicon oxide
(SiO2) due to arc energy. If silicon oxide accumulates on the
contacts, contact interference can occur. If silicon oil, silicon filling
agents, silicon cables, or other silicon products are present near
the Switch, suppress arcing with contact protective circuits (surge
killers) or remove the source of silicon gas.
Installing the Switch
• To install the Switch, make a mounting panel, as shown in the
following diagram, and tighten screws using the correct torque.
Front Mountig : Four, 5.2 +0.2
0 dia. holes
or M5 tapped holes
58.7±0.15
Rear Mountig : Four, 6.2 +0.2
0 dia. holes
30.2 ±0.15
WL-N/WLM-N
Tightening Torque
Overtravel Markers
• If screws are too loose they can lead
to an early malfunction of the Switch,
so ensure that all screws are
tightened using the correct torque.
• In particular, when changing the
direction of the Head, make sure that
all screws are tightened again to the
correct torque. Do not allow foreign
objects to fall into the Switch.
(1)
(3)
(6)
• All Switches with Roller Lever Actuators except for Switches with
Fork Lever Locks and Low-temperature Switches have a set
position marker plate.
• To allow the roller lever type actuator to travel properly, set the
roller lever according to the dog or cam stroke so that the
arrowhead of the lever is positioned within overtravel markers as
shown.
Head
(4)
Screw down
Arrowhead
(2)
Excessive OT
Setting range
Shortage OT
Setting range
Excessive OT
(5)
No.
Type
Torque
Screw type
Head mounting screw
0.78 to 0.88
N•m
M3.5 screw
(2)
Cover mounting screw
1.18 to 1.37
N•m
M4 screw
(3)
Allen-head bolt
(for securing the roller lever)
4.90 to 5.88
N•m
M5 hexagon socket
head cap screw
(3)
Allen-head bolt
(for securing the adjustable
rod lever)
0.88 to 1.08
N•m
M8 hexagon socket set
screw
(4)
Terminal screw
0.59 to 0.78
N•m
M3.5 screw
(5)
Connector
1.77 to 2.16
N•m
G1/2orPg13.5orM20or
1/2-14NPT
(6)
Unit mounting screw
4.90 to 5.88
N•m
M5 hexagon socket
head cap screw
(1)
Wring
In the case of mounting screw
• Use M3.5-nylon insulation covered crimp terminals (round type) for
wiring.
Ex.) V1.25-M3.5(RAP1.25-3.5) (J.S.T. Mfg. Co.,Ltd.)
• Appropriate wire size is AWG16 (1.25mm2).
• Do not supply electric power when wiring.
Otherwise electric shock may result.
• Do not pull out the wires with excessive force.
It may cause of coming off the wire.
• Use crimp terminals for wiring.
• In the case of lump unit, to avoid interference
between lump unit and crimp terminals, wire
according to right wiring figure.
Attach the lump unit spring to terminal screw
certainly otherwise itÅfs possible to be destroyed
or shorted.
• The ground terminal is only installed on models
with ground terminals.
In the case of prewired connecter and direct connecter
• Holding the connecter certainly when pulling connecter.
• Don’t pull the cable holding it.
How to handle
Connectors
• Tighten the connector with the appropriate torque to prevent
deformation.
• Use the OMRON type SC connector series, which is prepared
separately, suitable for outer diameter of cable and inner diameter
of seal rubber.
• Make sure to wrap the connector with the seal tape, except the
connector which has O-ring, to keep the sealability.
• To conform to CSA, use a CSA certified water tight treated conduit
hub.
• Even when the connector is assembled and set correctly, the end
of the cable and the inside of the Switch may come in contact. This
can lead to malfunction, leakage current, or fire, so be sure to
protect the end of the cable from splashes of oil or water and
corrosive gases.
Microload Applications
• The switch contacts can be used both for standard loads and
microloads, but once a contact has been used to open and close a
load it can no longer be used for lower loads. Doing so will damage
the contact surface and reduce contact reliability.
• If an inrush current or other sudden load occurs during a switch
operation, the switch will begin to degrade severely which can
result in reduced durability.
Use a contact protection circuit if required.
Indicator
Indicator-equipped switch has contacts and indicator in parallel.
When contacts are open, leakage current flows through the indicator
circuit and may cause load's malfunction.
Please check the load's OFF current before use the indicatorequipped
switch. Leakage current may cause load malfunction (i.e., the load
may remain ON). Make sure that the load operating current is higher
than the leakage current.
For countermeasures, refer to technical support on your OMRON
website.
Terminal Plate
• By using the Terminal Plate (sold separately), as shown in the
following diagram, the Switch can be used as a single-polarity
double-break switch.
Changing direction of the head
Attach the Terminal Plate
so that the “COM” mark is
oriented as shown on the left.
• By removing the screws in the two corners of the head, the head
can be set any of four directions. Be sure to change the plunger for
internal operations at the same time.
Built-in Switch
• Do not remove or replace the built-in switch.
Terminal Plate
Model
WL-N TERMINAL PLATE
Terminal Plate Mounting Diagram
(with Two Terminal Screws Removed)
45
WL-N/WLM-N
Using a WL@-2N Switch Mounted from the Side
If you replace a previous Switch with a WL@-2N-N Switch, a Mounting
Plate (sold separately) is available to maintain mounting compatibility.
If you use the Mounting Plate, the Switch mounting holes and actuator
position will be compatible. (The position of the dog will not need to
be changed.)
• With a roller actuator, the dog must touch the actuator at a right
angle. The actuator or shaft may deform or break if the dog touches
the actuator (roller) at an oblique angle.
Incorrect
Correct
Dog
Dog
64
58.7
Mounting Plate
Plate mounting
bolts (2)
Set
contents
• Make sure that the actuator does not exceed the OT (overtravel)
range, otherwise the Limit Switch may malfunction. When mounting
the Limit Switch, be sure to adjust the Limit Switch carefully while
considering the whole movement of the actuator.
Operating
body
23
30.2
WL@-2N
Mounting Plate
Replacing a Switch
with the WL@-2N-N
Plate (1)
Model
PT (Pretravel)
Switch mounting
bolts (2)
Install a stopper.
WLN-P001
70% of
100% of
rated OT
rated OT
Operation
• Carefully determine the position and shape of the dog or cam so that
the actuator will not abruptly snap back, thus causing shock. In order
to operate the Limit Switch at a comparatively high speed, use a dog
or cam that keeps the Limit Switch turned ON for a sufficient time so
that the relay or valve will be sufficiently energized.
• The method of operation, the shape of the cam or dog, the
operating frequency, and the travel after operation have a large
influence on the durability and operating accuracy of the Limit
Switch. The cam or dog must be smooth in shape.
Incorrect
Correct
FP (Free position)
OP (Operating position)
OT (Overtravel)
TTP (Total travel position)
Optimum setting range
Distance to the
optimum setting range.
Reference line
• The Limit Switch may soon malfunction if the OT is excessive.
Therefore, adjustments and careful consideration of the position of
the Limit Switch and the expected OT of the operating body are
necessary when mounting the Limit Switch.
Correct
Snapped
back
Abruptly
actuated
Incorrect
Stopper
Correct
• When using a pin-plunger actuator, make sure that the stroke of the
actuator and the movement of the dog are located along a single
straight line.
Incorrect
Snapped
back Abruptly
Correct
actuated
Operating
body
Operating
body
• Appropriate force must be imposed on the actuator by the cam or
dog in both rotary operation and linear operation.
If the dog touches the lever as shown below, the operating position
will not be stable.
Incorrect
Dog
Correct
Dog
Others
• Unbalanced force must not be imposed on the actuator. Otherwise,
wear and tear on the actuator may result.
Incorrect
Dog
Roller
46
Correct
Dog
Roller
• For long term (over a year) storage, check according to Operating
characteristics, Contact resistance and Dielectric strength at least.
And check with using condition.
• The durability of the Switch is greatly affected by operating
conditions.
Evaluate the Switch under actual working conditions before
permanent installation and use the Switch within a number of
switching operations that will not adversely affect the SwitchÅfs
performance.
WL-N/WLM-N
Using the Switches
Item
Applicable models and Actuators
Changing the Installation Position
of the Actuator
By loosening the Allen-head bolt on
the actuator lever, the position of the
actuator can be set anywhere within
the 360°.
With Indicator-equipped Switches, the
actuator lever comes in contact with
the top of the indicator cover, so use
caution when rotating and setting the
lever.
When the lever only moves forwards
and backwards, it will not contact the
lamp cover.
(This does not apply to Long-life
Switches.)
Roller Levers:
(WLCA2-N, WLCA2-2-N,
WLCA2-2N-N, WLG2-N,
WLCA2-7-N, WLCA2-8-N,
WLGCA2-N, WLMCA2-N,
WLMG2-N, WLMGCA2-N)
Adjustable Roller Levers:
(WLCA12-N, WLCA12-2-N,
WLCA12-2N-N, WLG12-N)
Adjustable rod lever:
(WLCL-N, WLCL-2-N,
WLCL-2N-N, WLGL-N,
WLCAL4-N, WLCAL5-N)
Changing the Orientation of the
Head
By removing the two screws of the
Head, the Head can be set in any of
the four directions.
Be sure to change the plunger for
internal operations at the same time.
The roller plunger can be set in either
of two positions at 90°
Roller Levers:
(WLCA2-N, WLCA2-2-N,
WLCA2-2N-N, WLG2-N,
WLCA2-7-N, WLCA2-8-N,
WLGCA2-N, WLMCA2-N,
WLMG2-N, WLMGCA2-N)
Adjustable Roller Levers:
(WLCA12-N, WLCA12-2-N,
WLCA12-2N-N, WLG12-N)
Adjustable rod lever:
(WLCL-N, WLCL-2-N,
WLCL-2N-N, WLGL-N,
WLCAL4-N, WLCAL5-N)
Horizontal plunger
(WLSD@-N)
Sealed top-roller plunger
(WLD28-N)
Note: Does not include the -RP60
Series or -141 Series.
Details
Loosen the Allen-head bolt, set
the actuator's position and then
tighten the bolt again.
Head
Loosen the screws.
p
Changing the Operating Direction
By removing the Head on models
which can operate on one-side only,
and then changing the direction of the
operational plunger, one of three
operating directions can be selected.
Roller Levers:
(WLCA2-N, WLCA2-2-N,
WLCA2-2N-N, WLG2-N,
WLCA2-7-N, WLCA2-8-N,
WLGCA2-N, WLMCA2-N,
WLMG2-N, WLMGCA2-N)
Adjustable Roller Levers:
(WLCA12-N, WLCA12-2-N,
WLCA12-2N-N, WLG12-N)
Adjustable rod lever:
(WLCL-N, WLCL-2-N,
WLCL-2N-N, WLGL-N,
WLCAL4-N, WLCAL5-N)
The output of the Switch will be
changed, regardless of which
direction the lever is pushed.
Operating
Operating
Operation in both
directions
Installing the Roller on the Inside
By installing the roller lever in the
opposite direction, the roller can be
installed on the inside.
(Set so that operation can be
completed within a 180° level range.)
Roller Levers:
(WLCA2-N, WLCA2-2-N,
WLCA2-2N-N, WLG2-N,
WLCA2-7-N, WLCA2-8-N,
WLGCA2-N, WLMCA2-N,
WLMG2-N, WLMGCA2-N)
Fork lever lock:
(WLCA32-4@-N)
Note: Except for Switches with
variable roller levers.
The output of the Switch will
only be changed when the lever
is pushed in one direction.
Not operating Operating
Clockwise operation
Operating
Not operating
Counterclockwise
operation
Loosen the
Allen-head bolt.
47
WL-N/WLM-N
Item
Applicable models and Actuators
Details
Adjustment
range radius:
24 to 140 mm
Adjusting the Length of the Rod or
Lever
The length of the rod or lever can be
adjusted by loosening the Allen-head
bolt.
Adjustable Roller Levers:
(WLCA12-N, WLCA12-2-N,
WLCA12-2N-N, WLG12-N)
Adjustable rod lever:
(WLCL-N, WLCL-2-N,
WLCL-2N-N, WLGL-N, WLCAL4-N)
Loosen this
Allen-head bolt
and adjust the
length of the
lever.
Adjustment
range radius:
25 to 89 mm
Adjustable Roller Levers:
Selecting the Roller Position
There are four types of Switches with Fork lever lock:
Fork Lever Locks for use depending on (WLCA32-4@-N)
the roller position.
Loosen this
Allen-head bolt
and adjust the
length of the rod.
Adjustable Rod Levers:
WLCA32-41-N
WLCA32-43-N
WLCA32-42-N
WLCA32-44-N
An explanation of the operation of fork lever locks is provided after this
table.
Operation of Fork Lever Locks
A Switch with a Fork Lever Lock is constructed so that the dog pushes the lever to invert the output and this inverted state is maintained even after
the dog moves on.
If the dog then pushes the lever from the opposite direction, the lever will return to its original position.
Example
NC terminal: ON
48
NO terminal: ON
NO terminal: ON
WL-N/WLM-N
Limit Switch Connectors
Connectors (SC Series)
Cabtire cables and flexible tubes with various diameters are used to
connect machine tools and controllers with Limit Switches. To ensure
the watertightness of the edges of the conduits, use an SC Connector
that is suitable for the external diameter of cable and model of Limit
Switch.
Ordering Information
Connector for Cabtire Cable
Conduit
Applicable cable
Cabtire cable (generalpurpose)
JIS B 0202 G½
Cabtire cable (anticorrosive)
½-14NPT
Cabtire cable
Inner diameter (D)
of seal rubber
7 mm
9 mm
12.5 mm
14 mm
11 mm
7 mm
9 mm
12.5 mm
14 mm
11 mm
7 mm
9 mm
12.5 mm
14 mm
11 mm
External diameter of cable
Min.
Max.
5.5 mm
7.5 mm
7.5 mm
9.5 mm
11 mm
13 mm
12 mm
14 mm
9 mm
11 mm
5.5 mm
7.5 mm
7.5 mm
9.5 mm
11 mm
13 mm
12 mm
14 mm
9 mm
11 mm
5.5 mm
7.5 mm
7.5 mm
9.5 mm
11 mm
13 mm
12 mm
14 mm
9 mm
11 mm
Model
SC-1M
SC-2M
SC-3M
SC-4M
SC-5M
SC-21
SC-22
SC-23
SC-24
SC-25
SC-1PT
SC-2PT
SC-3PT
SC-4PT
SC-5PT
Applicable model
WL-N, D4A-@N, D4B-@N, ZE,
ZV, ZV2, XE, XV, XV2
D4A-@N
Note: Please use sealling tape with SC Connectors. SC-1M to SC-5M, however, are provided with an O-ring (NBR) and therefore sealing tape is not necessary to
ensure a proper seal.
Simple Connectors (Not Suitable for Locations Subject to Oil or Water)
Conduit
Applicable cable
JIS B 0202 G½
Pg13.5
JIS B 0202 G½
Cabtire cable
Inner diameter (D)
of seal rubber
External diameter of cable
Min.
Max.
Model
10.6 mm
8.5 mm
10.5 mm
SC-P2
9.6 mm
7.5 mm
9.5 mm
SC-P3
9 mm
7.5 mm
9 mm
SC-6
Applicable model
WL-N, D4A-@N, D4B-@N, ZE,
ZV, ZV2, XE, XV, XV2
WL@-G-N
WL-N, D4A-@N, D4N *,
D4N-@R *, D4B-@N, ZE, ZV,
ZV2, XE, XV, XV2
Note: Simple connector are made of resin. If more sealing capability is required, use one of SC-1M to SC-5M, which have metal casings.
Models marked with an asterisk (*) however, can only be used with resin connectors.
49
WL-N/WLM-N
Dimensions and Structure
(Unit: mm)
Connectors for Cabtire Cable
As for models without an O-ring, please use sealing tape with SC Connectors.
Metal Models without O-ring
G½
SC-21 to 25
JIS B 0202 G½
14.6 dia.
*E
15
4.8
9
24
14 dia.
27.7
29.3
Ball head lock nut
(brass and nickel plating)
Washer (stainless steel)
Sealing rubber
(nitrile rubber)
Connector
(brass and nickel plating)
*D
(34)
Metal Models with O-ring
G½
SC-1M to 5M
14.6 dia.
*E
15
JIS B 0202 G½
5 9
29.3
27
14 dia.
Ball head lock nut
(zinc die-cast and zinc plating)
Washer (stainless steel)
*D
30
Sealing rubber (nitrile rubber)
(34)
Metal Models without O-ring
½-14NPT
(U.S.-standard screws)
SC-1PT to 5PT
14.6 dia.
14 dia.
15
Sealing rubber
(nitrile rubber)
Connector
(zinc die-cast and
zinc plating)
5
14
29.3
½-14NPT
24
14 dia.
Ball head lock nut
(zinc die-cast and zinc plating)
Washer (stainless steel)
Sealing rubber (nitrile rubber)
Connector
(zinc die-cast and
zinc plating)
*D
27.7
(39)
Note: Dimensions not shown in the above diagrams have a variation of ±0.4 mm.
Simple Connectors (Not Suitable for Locations Subject to Oil or Water)
Resin Models
G½
SC-P2
15
22
5
18 dia.
12.6 dia.
25.4
Resin Models
Pg13.5
SC-P3
15.5
5
21
Pg13.5
1
22.5
12
9
12
5
9
Note: Dimensions not shown in the above diagrams have a variation of ±0.4 mm.
* Diameter of Part Marked with Asterisk
SC-21, -1M, -1PT
SC-22, -2M, -2PT
SC-23, -3M, -3PT
SC-24, -4M, 4PT
SC-25, -5M, -5PT
SC-6
50
Internal diameter
(E) of washer
10.4 mm
13.2 mm
14.6 mm
14.6 mm
13.2 mm
10 mm
Ball head lock nut
(polyacetal resin)
Washer
(ferrous metal and
zinc plating)
*D
G½
Inner diameter (D)
of sealed rubber
7 mm
9 mm
12.5 mm
14 mm
11 mm
9 mm
4.5
Hexagonal nut
(polyacetal resin)
Conduit washer
(ferrous metal and
zinc plating)
Ring (chloroprene rubber)
Conduit washer
(ferrous metal and
zinc plating)
18 dia.
9.6 dia.
26
Model
Hexagonal nut
(polyacetal resin)
18 dia.
10.6 dia.
(30.6)
10
9
4.5
Ring (chloroprene rubber)
18 dia.
12 dia.
23.5
Resin Models
G½
SC-6
JIS B 0202
1
G½
Applicable cable
5.5 to 7.5-mm dia.
7.5 to 9.5-mm dia.
11 to 13-mm dia.
12 to 14-mm dia.
9 to 11-mm dia.
7.5 to 9-mm dia.
M20 × 1.5
Sealing rubber (nitrile rubber)
Connector
(polyacetal resin)
Terms and Conditions of Sale
1. Offer; Acceptance. These terms and conditions (these "Terms") are deemed
part of all quotes, agreements, purchase orders, acknowledgments, price lists,
catalogs, manuals, brochures and other documents, whether electronic or in
writing, relating to the sale of products or services (collectively, the "Products")
by Omron Electronics LLC and its subsidiary companies (“Omron”). Omron
objects to any terms or conditions proposed in Buyer’s purchase order or other
documents which are inconsistent with, or in addition to, these Terms.
2. Prices; Payment Terms. All prices stated are current, subject to change without notice by Omron. Omron reserves the right to increase or decrease prices
on any unshipped portions of outstanding orders. Payments for Products are
due net 30 days unless otherwise stated in the invoice.
3. Discounts. Cash discounts, if any, will apply only on the net amount of invoices
sent to Buyer after deducting transportation charges, taxes and duties, and will
be allowed only if (i) the invoice is paid according to Omron’s payment terms
and (ii) Buyer has no past due amounts.
4. Interest. Omron, at its option, may charge Buyer 1-1/2% interest per month or
the maximum legal rate, whichever is less, on any balance not paid within the
stated terms.
5. Orders. Omron will accept no order less than $200 net billing.
6. Governmental Approvals. Buyer shall be responsible for, and shall bear all
costs involved in, obtaining any government approvals required for the importation or sale of the Products.
7. Taxes. All taxes, duties and other governmental charges (other than general
real property and income taxes), including any interest or penalties thereon,
imposed directly or indirectly on Omron or required to be collected directly or
indirectly by Omron for the manufacture, production, sale, delivery, importation, consumption or use of the Products sold hereunder (including customs
duties and sales, excise, use, turnover and license taxes) shall be charged to
and remitted by Buyer to Omron.
8. Financial. If the financial position of Buyer at any time becomes unsatisfactory
to Omron, Omron reserves the right to stop shipments or require satisfactory
security or payment in advance. If Buyer fails to make payment or otherwise
comply with these Terms or any related agreement, Omron may (without liability and in addition to other remedies) cancel any unshipped portion of Products sold hereunder and stop any Products in transit until Buyer pays all
amounts, including amounts payable hereunder, whether or not then due,
which are owing to it by Buyer. Buyer shall in any event remain liable for all
unpaid accounts.
9. Cancellation; Etc. Orders are not subject to rescheduling or cancellation
unless Buyer indemnifies Omron against all related costs or expenses.
10. Force Majeure. Omron shall not be liable for any delay or failure in delivery
resulting from causes beyond its control, including earthquakes, fires, floods,
strikes or other labor disputes, shortage of labor or materials, accidents to
machinery, acts of sabotage, riots, delay in or lack of transportation or the
requirements of any government authority.
11. Shipping; Delivery. Unless otherwise expressly agreed in writing by Omron:
a. Shipments shall be by a carrier selected by Omron; Omron will not drop ship
except in “break down” situations.
b. Such carrier shall act as the agent of Buyer and delivery to such carrier shall
constitute delivery to Buyer;
c. All sales and shipments of Products shall be FOB shipping point (unless otherwise stated in writing by Omron), at which point title and risk of loss shall
pass from Omron to Buyer; provided that Omron shall retain a security interest in the Products until the full purchase price is paid;
d. Delivery and shipping dates are estimates only; and
e. Omron will package Products as it deems proper for protection against normal handling and extra charges apply to special conditions.
12. Claims. Any claim by Buyer against Omron for shortage or damage to the
Products occurring before delivery to the carrier must be presented in writing
to Omron within 30 days of receipt of shipment and include the original transportation bill signed by the carrier noting that the carrier received the Products
from Omron in the condition claimed.
13. Warranties. (a) Exclusive Warranty. Omron’s exclusive warranty is that the
Products will be free from defects in materials and workmanship for a period of
twelve months from the date of sale by Omron (or such other period expressed
in writing by Omron). Omron disclaims all other warranties, express or implied.
(b) Limitations. OMRON MAKES NO WARRANTY OR REPRESENTATION,
EXPRESS OR IMPLIED, ABOUT NON-INFRINGEMENT, MERCHANTABIL-
14.
15.
16.
17.
18.
ITY OR FITNESS FOR A PARTICULAR PURPOSE OF THE PRODUCTS.
BUYER ACKNOWLEDGES THAT IT ALONE HAS DETERMINED THAT THE
PRODUCTS WILL SUITABLY MEET THE REQUIREMENTS OF THEIR
INTENDED USE. Omron further disclaims all warranties and responsibility of
any type for claims or expenses based on infringement by the Products or otherwise of any intellectual property right. (c) Buyer Remedy. Omron’s sole obligation hereunder shall be, at Omron’s election, to (i) replace (in the form
originally shipped with Buyer responsible for labor charges for removal or
replacement thereof) the non-complying Product, (ii) repair the non-complying
Product, or (iii) repay or credit Buyer an amount equal to the purchase price of
the non-complying Product; provided that in no event shall Omron be responsible for warranty, repair, indemnity or any other claims or expenses regarding
the Products unless Omron’s analysis confirms that the Products were properly handled, stored, installed and maintained and not subject to contamination, abuse, misuse or inappropriate modification. Return of any Products by
Buyer must be approved in writing by Omron before shipment. Omron Companies shall not be liable for the suitability or unsuitability or the results from the
use of Products in combination with any electrical or electronic components,
circuits, system assemblies or any other materials or substances or environments. Any advice, recommendations or information given orally or in writing,
are not to be construed as an amendment or addition to the above warranty.
See http://www.omron247.com or contact your Omron representative for published information.
Limitation on Liability; Etc. OMRON COMPANIES SHALL NOT BE LIABLE
FOR SPECIAL, INDIRECT, INCIDENTAL, OR CONSEQUENTIAL DAMAGES,
LOSS OF PROFITS OR PRODUCTION OR COMMERCIAL LOSS IN ANY
WAY CONNECTED WITH THE PRODUCTS, WHETHER SUCH CLAIM IS
BASED IN CONTRACT, WARRANTY, NEGLIGENCE OR STRICT LIABILITY.
Further, in no event shall liability of Omron Companies exceed the individual
price of the Product on which liability is asserted.
Indemnities. Buyer shall indemnify and hold harmless Omron Companies and
their employees from and against all liabilities, losses, claims, costs and
expenses (including attorney's fees and expenses) related to any claim, investigation, litigation or proceeding (whether or not Omron is a party) which arises
or is alleged to arise from Buyer's acts or omissions under these Terms or in
any way with respect to the Products. Without limiting the foregoing, Buyer (at
its own expense) shall indemnify and hold harmless Omron and defend or settle any action brought against such Companies to the extent based on a claim
that any Product made to Buyer specifications infringed intellectual property
rights of another party.
Property; Confidentiality. Any intellectual property in the Products is the exclusive property of Omron Companies and Buyer shall not attempt to duplicate it
in any way without the written permission of Omron. Notwithstanding any
charges to Buyer for engineering or tooling, all engineering and tooling shall
remain the exclusive property of Omron. All information and materials supplied
by Omron to Buyer relating to the Products are confidential and proprietary,
and Buyer shall limit distribution thereof to its trusted employees and strictly
prevent disclosure to any third party.
Export Controls. Buyer shall comply with all applicable laws, regulations and
licenses regarding (i) export of products or information; (iii) sale of products to
“forbidden” or other proscribed persons; and (ii) disclosure to non-citizens of
regulated technology or information.
Miscellaneous. (a) Waiver. No failure or delay by Omron in exercising any right
and no course of dealing between Buyer and Omron shall operate as a waiver
of rights by Omron. (b) Assignment. Buyer may not assign its rights hereunder
without Omron's written consent. (c) Law. These Terms are governed by the
law of the jurisdiction of the home office of the Omron company from which
Buyer is purchasing the Products (without regard to conflict of law principles). (d) Amendment. These Terms constitute the entire agreement between
Buyer and Omron relating to the Products, and no provision may be changed
or waived unless in writing signed by the parties. (e) Severability. If any provision hereof is rendered ineffective or invalid, such provision shall not invalidate
any other provision. (f) Setoff. Buyer shall have no right to set off any amounts
against the amount owing in respect of this invoice. (g) Definitions. As used
herein, “including” means “including without limitation”; and “Omron Companies” (or similar words) mean Omron Corporation and any direct or indirect
subsidiary or affiliate thereof.
Certain Precautions on Specifications and Use
1. Suitability of Use. Omron Companies shall not be responsible for conformity
with any standards, codes or regulations which apply to the combination of the
Product in the Buyer’s application or use of the Product. At Buyer’s request,
Omron will provide applicable third party certification documents identifying
ratings and limitations of use which apply to the Product. This information by
itself is not sufficient for a complete determination of the suitability of the Product in combination with the end product, machine, system, or other application
or use. Buyer shall be solely responsible for determining appropriateness of
the particular Product with respect to Buyer’s application, product or system.
Buyer shall take application responsibility in all cases but the following is a
non-exhaustive list of applications for which particular attention must be given:
(i) Outdoor use, uses involving potential chemical contamination or electrical
interference, or conditions or uses not described in this document.
(ii) Use in consumer products or any use in significant quantities.
(iii) Energy control systems, combustion systems, railroad systems, aviation
systems, medical equipment, amusement machines, vehicles, safety equipment, and installations subject to separate industry or government regulations.
(iv) Systems, machines and equipment that could present a risk to life or property. Please know and observe all prohibitions of use applicable to this Product.
NEVER USE THE PRODUCT FOR AN APPLICATION INVOLVING SERIOUS
RISK TO LIFE OR PROPERTY OR IN LARGE QUANTITIES WITHOUT
ENSURING THAT THE SYSTEM AS A WHOLE HAS BEEN DESIGNED TO
2.
3.
4.
5.
ADDRESS THE RISKS, AND THAT THE OMRON’S PRODUCT IS PROPERLY RATED AND INSTALLED FOR THE INTENDED USE WITHIN THE
OVERALL EQUIPMENT OR SYSTEM.
Programmable Products. Omron Companies shall not be responsible for the
user’s programming of a programmable Product, or any consequence thereof.
Performance Data. Data presented in Omron Company websites, catalogs
and other materials is provided as a guide for the user in determining suitability and does not constitute a warranty. It may represent the result of Omron’s
test conditions, and the user must correlate it to actual application requirements. Actual performance is subject to the Omron’s Warranty and Limitations
of Liability.
Change in Specifications. Product specifications and accessories may be
changed at any time based on improvements and other reasons. It is our practice to change part numbers when published ratings or features are changed,
or when significant construction changes are made. However, some specifications of the Product may be changed without any notice. When in doubt, special part numbers may be assigned to fix or establish key specifications for
your application. Please consult with your Omron’s representative at any time
to confirm actual specifications of purchased Product.
Errors and Omissions. Information presented by Omron Companies has been
checked and is believed to be accurate; however, no responsibility is assumed
for clerical, typographical or proofreading errors or omissions.
OMRON AUTOMATION AND SAFETY • THE AMERICAS HEADQUARTERS • Chicago, IL USA • 847.843.7900 • 800.556.6766 • www.omron247.com
OMRON CANADA, INC. • HEAD OFFICE
Toronto, ON, Canada • 416.286.6465 • 866.986.6766 • www.omron247.com
OMRON ARGENTINA • SALES OFFICE
Cono Sur • 54.11.4783.5300
OMRON ELECTRONICS DE MEXICO • HEAD OFFICE
México DF • 52.55.59.01.43.00 • 01-800-226-6766 • mela@omron.com
OMRON CHILE • SALES OFFICE
Santiago • 56.9.9917.3920
OMRON ELECTRONICS DE MEXICO • SALES OFFICE
Apodaca, N.L. • 52.81.11.56.99.20 • 01-800-226-6766 • mela@omron.com
OTHER OMRON LATIN AMERICA SALES
54.11.4783.5300
OMRON ELETRÔNICA DO BRASIL LTDA • HEAD OFFICE
São Paulo, SP, Brasil • 55.11.2101.6300 • www.omron.com.br
OMRON EUROPE B.V. • Wegalaan 67-69, NL-2132 JD, Hoofddorp, The Netherlands. • +31 (0) 23 568 13 00 • www.industrial.omron.eu
Authorized Distributor:
Automation Control Systems
• Machine Automation Controllers (MAC) • Programmable Controllers (PLC)
• Operator interfaces (HMI) • Distributed I/O • Software
Drives & Motion Controls
• Servo & AC Drives • Motion Controllers & Encoders
Temperature & Process Controllers
• Single and Multi-loop Controllers
Sensors & Vision
• Proximity Sensors • Photoelectric Sensors • Fiber-Optic Sensors
• Amplified Photomicrosensors • Measurement Sensors
• Ultrasonic Sensors • Vision Sensors
Industrial Components
• RFID/Code Readers • Relays • Pushbuttons & Indicators
• Limit and Basic Switches • Timers • Counters • Metering Devices
• Power Supplies
Safety
• Laser Scanners • Safety Mats • Edges and Bumpers • Programmable Safety
Controllers • Light Curtains • Safety Relays • Safety Interlock Switches
$&@@
0/14
Note: Specifications are subject to change.
Printed on recycled paper.
© 2014 Omron Electronics LLC
Printed in U.S.A.