Standard-type Connector-Terminal Block Conversion Units
XW2B
CSM_XW2B_DS_E_4_2
Simplifies Connector and terminal
block replacement, and requires less
in-panel wiring.
• Mount to DIN Track or via screws.
• MIL Flat Cable Connectors and Multi-pole, Square
Connectors are standard.
• Terminal blocks available with either M3 or M3.5 screws.
• Connecting Cables for Programmable Controllers
available (sold separately).
Ordering Information
Connectors
Type
Terminal Block
Connector
Terminal block with
M3 screws
Flat Cable
Terminal block with
M3.5 screws
Flat Cable Connectors
*1
Twin-connector
No. of poles
Appearance
Model
20
XW2B-20G4
34
XW2B-34G4
40
XW2B-40G4
50
XW2B-50G4
60
XW2B-60G4
20
XW2B-20G5
34
XW2B-34G5
40
XW2B-40G5
50
XW2B-50G5
60
XW2B-60G5
40
XW2B-40G5-T
20
XW2B-20G5-D
20
XW2B-20Y4
34
XW2B-34Y4
50
XW2B-50Y4
50
XW2B-50Y5
Terminal block with
M3.5 screws
Daisy Chain
Terminal block with
M3 screws
Multi-pole, Square
Connector
Terminal block with
M3.5 screws
Multi-pole, Square Connector
Plugs
*2
*1. Flat Cable Connectors have one polarity slot.
*2. These Plugs and Sockets are made by Honda Tsushin Kogyo.
Accessories (Order Separately)
Connecting Cables for Connector-Terminal Block Conversion Units
For details on the Connecting Cable used between XW2B Daisy Chain-type Connectors, refer to the XW2Z datasheet.
1
XW2B
Ratings and Specifications
Type XW2B-@@G@
Flat Cable Units
Item
XW2B-@@Y@
XW2B-40F5-P
Multi-pole, Square-connector Units Board I/O Unit
Rated current
1A
Rated voltage
125 VAC
Insulation resistance
100 MΩ min. (at 500 VDC)
Dielectric strength
500 VAC for 1 min (leakage current: 1 mA max.)
Ambient operating
temperature
0 to 55°C
Dimensions
(Unit: mm)
Flat Cable Units with a Terminal Block with M3 Screws
XW2B-@@G4
Flat Cable Connector (MIL Plug)
A
3.5
3.5
15.5
29.5
45
Two,
3.5 dia.
5.08
Terminal Block
(45.3)
38.1
Wiring Diagram
Flat Cable
Connector
(mating side)
20.5
2
4
N-2
N
1
3
N-3
N-1
DIN Track lock
Dimensions
Triangular mark
Model
N-3
3
1
N-1
Terminal Block
(terminal side)
2
4
N-2
N
Note: All pins on the Flat Cable Connector correspond
1-to-1 to the terminal of the same number on the
terminal block as shown above.
No. of poles Dimension A (mm) Applicable Connector models *1
XW2B-20G4
20
67.5
XG4A-2031
XW2B-34G4
34
112.5
XG4A-3431
XW2B-40G4
40
135.0
XG4A-4031
XW2B-50G4
50
157.5
XG4A-5031
XW2B-60G4
60
180.0
XG4A-6031
*Flat Cable Connectors have one polarity slot.
Note: Terminal block pitch is 5.08 mm.
Use a wire size between 0.3 and 1.25 mm2 (AWG22 to AWG16).
The wire insertion holes are 1.8 × 2.5 (H × W) mm.
Applicable Connectors
Applicable Connectors (order separately)
Model
Flat Cable Connectors, MIL Sockets with
Strain Reliefs
Discrete-wire IDC Connectors, Double-row Sockets
Connectors *1
Semi-covers *2
XG5S-1001
XW2B-20G4
XG4M-2030-T
XG5M-2032-N
XG5M-2035-N
XW2B-34G4
XG4M-3430-T
XG5M-3432-N
XG5M-3435-N
XG5S-1701
XW2B-40G4
XG4M-4030-T
XG5M-4032-N
XG5M-4035-N
XG5S-2001
XW2B-50G4
XG4M-5030-T
XG5M-5032-N
XG5M-5035-N
XG5S-2501
XW2B-60G4
XG4M-6030-T
XG5M-6032-N
XG5M-6035-N
XG5S-3001
*1. Either the XG5M-@@32-N or the XG5M-@@35-N may be used.
*2. Each Connector requires two Semi-covers.
2
XW2B
Flat Cable Units with a Terminal Block with M3.5 Screws
XW2B-@@G5
Flat Cable Connector (MIL Plug)
3.5
3.5
15.5
29.5
45
Two,
3.5 dia.
7
8.5
7.3
Terminal
Block
7
43.5 (45.3)
Wiring Diagram
Flat Cable
Connector
(mating side)
2
4
1
3
20.5
N-2
N
N-3
N-1
DIN Track lock
Dimensions
Triangular mark
Model
N-3
3
1
N-1
Terminal Block
(terminal side)
2
4
N-2
N
Note: All pins on the Flat Cable Connector correspond
1-to-1 to the terminal of the same number on the
terminal block as shown above.
No. of poles Dimension A (mm)
Applicable Connector models *
XW2B-20G5
20
112.5
XW2B-34G5
34
180.0
XG4A-2031
XG4A-3431
XW2B-40G5
40
202.5
XG4A-4031
XW2B-50G5
50
247.5
XG4A-5031
XW2B-60G5
60
292.5
XG4A-6031
*Flat Cable Connectors have one polarity slot.
Note: Terminal block pitch is 8.5 mm.
Applicable Connectors
Applicable Connectors (order separately)
Model
Flat Cable Connectors, MIL Sockets with
Strain Reliefs
Discrete-wire IDC Connectors, Double-row Sockets
Connectors *1
Semi-covers *2
XW2B-20G5
XG4M-2030-T
XG5M-2032-N
XG5M-2035-N
XG5S-1001
XW2B-34G5
XG4M-3430-T
XG5M-3432-N
XG5M-3435-N
XG5S-1701
XW2B-40G5
XG4M-4030-T
XG5M-4032-N
XG5M-4035-N
XG5S-2001
XW2B-50G5
XG4M-5030-T
XG5M-5032-N
XG5M-5035-N
XG5S-2501
XW2B-60G5
XG4M-6030-T
XG5M-6032-N
XG5M-6035-N
XG5S-3001
*1. Either the XG5M-@@32-N or the XG5M-@@35-N may be used.
*2. Each Connector requires two Semi-covers.
3
XW2B
Twin-connector Units with a Terminal Block with M3.5 Screws
XW2B-40G5-T
Flat Cable Connector (MIL Plug: XG4A-2031 × 2)
3.5
202.5
3.5
15.5
29.5
45
Two,
3.5 dia.
7
8.5
7.3
7
Terminal Block
43.8 (45.3)
2
20.5
Wiring Diagram
DIN Track lock
Flat Cable
Connector
(mating side)
2
4
20
22
38
40
1
3
19
21
37
39
37
39
Triangular
mark
Triangular mark
Terminal Block
(terminal side)
3
1
2
21
19
4
20
38
22
40
Note: All pins on the Flat Cable Connector correspond 1-to-1 to the terminal of
the same number on the terminal block as shown above.
Applicable Connectors
Applicable Connectors (order separately)
Model
XW2B-40G5-T
Flat Cable Connectors, MIL Sockets with
Strain Reliefs
XG4M-2030-T
Discrete-wire IDC Connectors, Double-row Sockets
Connectors *1
Semi-covers *2
XG5M-2032-N
XG5M-2035-N
XG5S-1001
*1. Either the XG5M-@@32-N or the XG5M-@@35-N may be used.
*2. Each Connector requires two Semi-covers.
4
XW2B
Daisy Chain Units with a Terminal Block with M3.5 Screws
XW2B-20G5-D
3.5
Flat Cable Connector (MIL Plug: XG4A-2031 × 2)
135
3.5
15.5
29.5
45
Two,
3.5 dia.
7
7.3
8.5
7
Terminal Block
43.8 (45.3)
2
20.5
Wiring Diagram
DIN Track lock
Flat Cable
Connector
(mating side)
2
20
2
20
1
19
1
19
Triangular mark
Triangular mark
Terminal Block
(terminal side)
19
1
2
20
Note: All pins on the Flat Cable Connector correspond 1-to-1 to the terminal
of the same number on the terminal block as shown above.
Applicable Connectors
Applicable Connectors (order separately)
Model
XW2B-20G5-D
Flat Cable Connectors, MIL Sockets with
Strain Reliefs
XG4M-2030-T
Discrete-wire IDC Connectors, Double-row Sockets
Connectors *1
Semi-covers *2
XG5M-2032-N
XG5M-2035-N
XG5S-1001
*1. Either the XG5M-@@32-N or the XG5M-@@35-N may be used.
*2. Each Connector requires two Semi-covers.
5
XW2B
Multi-pole, Square-connector Plug Units with a Terminal Block with M3 Screws
XW2B-@@Y4
Multi-contact Connector (Plug)
A
3.5
3.5
15.5
29.5
45
Two,
3.5 dia.
Terminal Block
5.08
Wiring Diagram (Example for Terminal
Block with 50 Poles)
2
38.1
20.5
DIN Track lock
2
1
Multi-contact,
Square Connector
(mating side)
16
3
34
48
35
3
1
18
49
50
Dimensions
32
19
33
17
19
17
47
Model
4
16
18
49
48
Applicable Connector
models *
XW2B-20Y4
20
67.5
MR-20RMD2
XW2B-34Y4
34
112.5
MR-34RMD2
XW2B-50Y4
50
157.5
MR-50RMD2
*These Connectors are made by Honda Tsushin Kogyo.
Note: Terminal block pitch is 5.08 mm.
Use a wire size between 0.3 and 1.25 mm2 (AWG22 to AWG16).
The wire insertion holes are 1.8 × 2.5 (H × W) mm.
Terminal Block
(terminal side)
2
No. of poles Dimension A (mm)
50
Note: All pins on the Multi-pole, Square Connector correspond 1-to1 to the terminal of the same number on the terminal block as
shown above.
Applicable Connectors
Model
Applicable Connectors *1
Hood *1
XW2B-20Y4
MR-20F (soldered)
MRP-20F01 (crimped) *2
MR-20FW (wrapped)
MR-20L
XW2B-34Y4
MR-34F (soldered)
MRP-34F01 (crimped) *2
MR-34FW (wrapped)
MR-34L
XW2B-50Y4
MR-50F (soldered)
MRP-50F01 (crimped) *2
MR-50FW (wrapped)
MR-50L
*1. All applicable Connector Hoods are made by Honda Tsushin Kogyo.
*2. Use MRP-F113 or MRP-F103 crimp terminals made by Honda Tsushin Kogyo.
6
XW2B
Multi-pole, Square-connector Plug Units with a Terminal Block with M3.5 Screws
XW2B-50Y5
Multi-contact, Square Connector (Plug)
3.5
A
3.5
15.5
29.5
45
Two,
3.5 dia.
8.5
7.3
Terminal Block
43.8
Wiring Diagram (Example for Terminal
Block with 50 Poles)
2
20.5
DIN Track lock
Dimensions
2
1
Multi-contact,
Square Connector
(mating side)
16
3
34
18
Model
No. of
poles
Dimension A
(mm)
Applicable Connector
models *
XW2B-50Y5
50
247.5
MR-50RMD2
32
19
33
17
48
35
49
50
*These Connectors are made by Honda Tsushin Kogyo.
Note: Terminal block pitch is 8.5 mm.
3
1
19
17
47
49
Terminal Block
(terminal side)
2
4
16
18
48
50
Note: All pins on the Multi-pole, Square Connector correspond
1-to-1 to the terminal of the same number on the terminal
block as shown above.
Applicable Connectors
Model
Applicable Connectors *1
Hood *1
XW2B-50Y5
MR-50F (soldered)
MRP-50F01 (crimped) *2
MR-50FW (wrapped)
MR-50L
*1. All applicable Connector Hoods are made by Honda Tsushin Kogyo.
*2. Use MRP-F113 or MRP-F103 crimp terminals made by Honda Tsushin Kogyo.
7
XW2B
Multi-pole, Square Connector Socket Units with a Terminal Block with M3.5 Screws
XW2B-@@X5
Multi-contact, Square Connector (Socket)
3.5
A
3.5
15.5
29.5
45
Two,
3.5 dia.
8.5
7.3
Terminal Block
43.8
2
Wiring Diagram (Example for
Terminal Block with 50 Poles)
20.5
DIN Track lock
Dimensions
48
35
34
33
Multi-contact,
Square Connector
(mating side)
50
49
Model
2
1
No. of poles Dimension A (mm)
Applicable Connector models *
32
19
16
3
17
18
XW2B-20X5
20
112.5
XW2B-34X5
34
180.0
MR-20RFD2
MR-34RFD2
XW2B-50X5
50
247.5
MR-50RFD2
*These Connectors are made by Honda Tsushin Kogyo.
Note: Terminal block pitch is 8.5 mm.
3
1
19
17
47
49
Terminal Block
(terminal side)
2
4
16
18
48
50
Note: All pins on the Multi-pole, Square Connector correspond 1to-1 to the terminal of the same number on the terminal
block as shown above.
Applicable Connectors
Model
Applicable Connectors *1
Hood *1
XW2B-20X5
MR-20M (soldered)
MRP-20M01 (crimped) *2
MR-20MW (wrapped)
MR-20L
XW2B-34X5
MR-34M (soldered)
MRP-34M01 (crimped) *2
MR-34MW (wrapped)
MR-34L
XW2B-50X5
MR-50M (soldered)
MRP-50M01 (crimped) *2
MR-50MW (wrapped)
MR-50L
*1. All applicable Connector Hoods are made by Honda Tsushin Kogyo.
*2. Use MRP-F113 or MRP-F103 crimp terminals made by Honda Tsushin Kogyo.
8
XW2B
Board I/O Units with a Terminal Block with M3.5 Screws
XW2B-40F5-P
M2.6
I/O Board Connectors (40-pin Plug)
202.5
3.5
3.5
15.5
29.5
45
Two,
3.5 dia.
7.3
7
8.5
7
Terminal Block
43.8
2
20.5
DIN Track lock
Wiring Diagram
Dimensions
FCN-364P040-AU Plug B
(mating side)
A
1
2
19
20
Model
No. of poles
Applicable Connectors and Circuits *
1
2
19
20
XW2B-40F5-P
40
FCN-364P40-AU (Connector)
FCN-360A1 (Anchor)
*These Connectors and circuits are made by Fujitsu component.
Note: Terminal block pitch is 8.5 mm.
Terminal Block
(terminal side)
1
3
2
37
4
39
38
40
Applicable Connectors
Model
Applicable Connectors *1
Hood *1
XW2B-40F5-P
FCN361J040-AU (soldered)
FCN363J040-AAU (crimped)
FCN360C040B
*1. All applicable Connectors and Covers are made by Fujitsu component.
*2. Refer to the OMNUC U Series user's manual for details on the Connecting Cable used between the XW2B-40F5-P and the U-series AC Servo Driver.
9
XW2B
Safety Precautions
Precautions for Correct Use
● Wiring
• Always turn OFF the power supply before wiring.
Otherwise, cables or other conductors can short the
terminals and cause the Unit to fail.
• Do not connect or disconnect Connectors with the power
turned ON. Otherwise, it may cause malfunctions.
● Wiring Terminal Blocks
• Direct Wire Connections with a Terminal Block with M3
Screws
1. Use a wire size between 0.3 and 1.25 mm2 (AWG22 to
AWG16).
2. Prepare the end of each wire as shown in the following
diagram.
● Terminal Screw Tightening Torque
• Select a tightening torque from the following table when
connecting wires or crimp terminals to the terminal block.
Terminal Block
Tightening torque
N⋅m
With M3 screws
0.40
With M3.5 screws
0.59
● Mounting Units to and Removing Units from DIN Track
• For terminal blocks with M3 screws, use a flat-heat
screwdriver like the one shown in the following diagram.
2.9- to 3.5-mm blade
6 mm
Screw slot width: 0.7
3. The wire insertion holes are 1.8 × 2.5 (H × W) mm on the
terminal block with M3 screws.
• Direct Wire Connections with a Terminal Block with M3.5
Screws
Round
Forked
3.7 mm dia.
3.7 mm 6.8 mm max.
6.8 mm max.
Applicable crimp terminals
Applicable wires
1.25-3.5
AWG22 to AWG16
(0.30 to 1.25 mm2)
2-3.5
AWG16 to AWG14
(1.25 to 2.0 mm2)
1.25Y-3.5
AWG22 to AWG16
(0.30 to 1.25 mm2)
2Y-3.5
AWG16 to AWG14
(1.25 to 2.0 mm2)
Round
Forked
• XW2B Connector-Terminal Block Conversion Units can be
mounted side-to-side on DIN Track. The flanges for
mounting screws are located on each side at the bottom of
the XW2B.
• Secure both ends of the XW2B with End Plates.
• When removing the Unit from a DIN Track, insert a flat-head
screwdriver into the slider and pull the lock out.
(With a Terminal Block with M3 Screws)
Round rod
Blade
Dia.
W
t = 0.75
Applicable crimp terminals
Rod
Blade
Applicable wires
TC-05
Dia. = 1
AWG22 to AWG18
(0.30 to 0.75 mm2)
TC-1.25S
Dia. = 1.5
AWG22 to AWG16
(0.30 to 1.25 mm2)
BT1.25-9-1
BT1.25-10-1
W = 2.2
AWG22 to AWG16
(0.30 to 1.25 mm2)
Note: Round rod and blade crimp terminals are made by Nichifu.
10
Terms and Conditions Agreement
Read and understand this catalog.
Please read and understand this catalog before purchasing the products. Please consult your OMRON representative if you
have any questions or comments.
Warranties.
(a) Exclusive Warranty. Omron’s exclusive warranty is that the Products will be free from defects in materials and workmanship
for a period of twelve months from the date of sale by Omron (or such other period expressed in writing by Omron). Omron
disclaims all other warranties, express or implied.
(b) Limitations. OMRON MAKES NO WARRANTY OR REPRESENTATION, EXPRESS OR IMPLIED, ABOUT
NON-INFRINGEMENT, MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE OF THE PRODUCTS. BUYER
ACKNOWLEDGES THAT IT ALONE HAS DETERMINED THAT THE
PRODUCTS WILL SUITABLY MEET THE REQUIREMENTS OF THEIR INTENDED USE.
Omron further disclaims all warranties and responsibility of any type for claims or expenses based on infringement by the
Products or otherwise of any intellectual property right. (c) Buyer Remedy. Omron’s sole obligation hereunder shall be, at
Omron’s election, to (i) replace (in the form originally shipped with Buyer responsible for labor charges for removal or
replacement thereof) the non-complying Product, (ii) repair the non-complying Product, or (iii) repay or credit Buyer an amount
equal to the purchase price of the non-complying Product; provided that in no event shall Omron be responsible for warranty,
repair, indemnity or any other claims or expenses regarding the Products unless Omron’s analysis confirms that the Products
were properly handled, stored, installed and maintained and not subject to contamination, abuse, misuse or inappropriate
modification. Return of any Products by Buyer must be approved in writing by Omron before shipment. Omron Companies shall
not be liable for the suitability or unsuitability or the results from the use of Products in combination with any electrical or
electronic components, circuits, system assemblies or any other materials or substances or environments. Any advice,
recommendations or information given orally or in writing, are not to be construed as an amendment or addition to the above
warranty.
See http://www.omron.com/global/ or contact your Omron representative for published information.
Limitation on Liability; Etc.
OMRON COMPANIES SHALL NOT BE LIABLE FOR SPECIAL, INDIRECT, INCIDENTAL, OR CONSEQUENTIAL DAMAGES,
LOSS OF PROFITS OR PRODUCTION OR COMMERCIAL LOSS IN ANY WAY CONNECTED WITH THE PRODUCTS,
WHETHER SUCH CLAIM IS BASED IN CONTRACT, WARRANTY, NEGLIGENCE OR STRICT LIABILITY.
Further, in no event shall liability of Omron Companies exceed the individual price of the Product on which liability is asserted.
Suitability of Use.
Omron Companies shall not be responsible for conformity with any standards, codes or regulations which apply to the
combination of the Product in the Buyer’s application or use of the Product. At Buyer’s request, Omron will provide applicable
third party certification documents identifying ratings and limitations of use which apply to the Product. This information by itself
is not sufficient for a complete determination of the suitability of the Product in combination with the end product, machine,
system, or other application or use. Buyer shall be solely responsible for determining appropriateness of the particular Product
with respect to Buyer’s application, product or system. Buyer shall take application responsibility in all cases.
NEVER USE THE PRODUCT FOR AN APPLICATION INVOLVING SERIOUS RISK TO LIFE OR PROPERTY OR IN LARGE
QUANTITIES WITHOUT ENSURING THAT THE SYSTEM AS A WHOLE HAS BEEN DESIGNED TO ADDRESS THE RISKS,
AND THAT THE OMRON PRODUCT(S) IS PROPERLY RATED AND INSTALLED FOR THE INTENDED USE WITHIN THE
OVERALL EQUIPMENT OR SYSTEM.
Programmable Products.
Omron Companies shall not be responsible for the user’s programming of a programmable Product, or any consequence
thereof.
Performance Data.
Data presented in Omron Company websites, catalogs and other materials is provided as a guide for the user in determining
suitability and does not constitute a warranty. It may represent the result of Omron’s test conditions, and the user must correlate
it to actual application requirements. Actual performance is subject to the Omron’s Warranty and Limitations of Liability.
Change in Specifications.
Product specifications and accessories may be changed at any time based on improvements and other reasons. It is our
practice to change part numbers when published ratings or features are changed, or when significant construction changes are
made. However, some specifications of the Product may be changed without any notice. When in doubt, special part numbers
may be assigned to fix or establish key specifications for your application. Please consult with your Omron’s representative at
any time to confirm actual specifications of purchased Product.
Errors and Omissions.
Information presented by Omron Companies has been checked and is believed to be accurate; however, no responsibility is
assumed for clerical, typographical or proofreading errors or omissions.
2017.6
In the interest of product improvement, specifications are subject to change without notice.
OMRON Corporation
Industrial Automation Company
http://www.ia.omron.com/