DeviceNet Safety
CSM_DeviceNet_Safety_OP_E_3_1
Accessories
Terminal Blocks for the NE1A
Appearance
Specification
Applicable
Controllers
Screw terminal blocks
(4 pins)
Model
Remarks
Y9S-04T1B-02A
A set including two screw terminal
blocks (black) and six code marks to
prevent incorrect insertion
Y9S-04C1B-02A
A set including two spring-cage
terminal blocks (black) and six code
marks to prevent incorrect insertion
NE1A-SCPU01
NE1A-SCPU01-V1
NE1A-SCPU02
NE1A-EDR01
Spring-cage terminal
blocks (4 pins)
Note: The standard NE1A Controllers are equipped with spring-cage terminal blocks. Screw terminal blocks can be ordered if desired, e.g., to
replace previous terminals.
Terminal Blocks for the DST1
Appearance
Specification
Applicable Safety I/O
Terminals
Screw terminal blocks
(10 pins)
Model
Remarks
Y9S-10T1B-04B
A set including four screw terminal
blocks (black), six code marks to
prevent incorrect insertion, one set of
terminal labels *, and code mark
instructions
Y9S-10C1B-04B
A set including four spring-cage
terminal blocks (black), six code
marks to prevent incorrect insertion,
one set of terminal labels *, and code
mark instructions
DST1-ID12SL-1
DST1-MD16SL-1
DST1-XD0808SL-1
DST1-MRD08SL-1
Spring-cage terminal
blocks (10 pins)
Note: The standard DS1T Safety I/O Terminals are equipped with spring-cage terminal blocks. Screw terminal blocks can be ordered if desired,
e.g., to replace previous terminals.
* The set of terminal labels is one sheet containing four sets of labels required for one Terminal Block, i.e., [1, 2 ... 10], [11, 12 ... 20], [21, 22 ...
30] and [31, 32 ... 40].
1
DeviceNet Safety
Peripheral Devices for DeviceNet Communications
Product
Appearance
Model
DCN1-1NC
DCN1-1C
T-branch Tap for 1
branch line
DCN1-2C
Cable wiring direction: Toward top
Cable lock direction: From top
Connector screw direction: From top
Provided with 3 parallel connectors
with clamps (XW4G-05C1-H1-D),
standard terminating resistor
Cable wiring direction: Toward side
Cable screw direction: From top
Connector screw direction: From side Provided with 3 parallel connectors
with screws (XW4B-05C1-H1-D),
standard terminating resistor
Cable wiring direction: Toward top
Cable screw direction: From side
Connector screw direction: From top
DCN1-2R
Cable wiring direction: Toward side
Cable screw direction: From top
Connector screw direction: From top
Provided with 3 orthogonal
connectors with screws (XW4B05C1-V1R-D), standard terminating
resistor
DCN1-3NC
Cable wiring direction: Toward top
Cable lock direction: From top
Connector screw direction: From top
Provided with 5 parallel clamp
connectors with screws (XW4G05C1-H1-D), standard terminating
resistor
DCN1-3C
T-branch Tap for 3
branch lines
DCN1-4C
Power Supply Tap
Specification
Cable wiring direction: Toward side
Cable screw direction: From top
Connector screw direction: From side Provided with 5 parallel connectors
with screws (XW4B-05C1-H1-D),
standard terminating resistor
Cable wiring direction: Toward top
Cable screw direction: From side
Connector screw direction: From top
Provided with 5 orthogonal clamp
connectors with screws (XW4B05C1-V1R-D), standard terminating
resistor
DCN1-4R
Cable wiring direction: Toward side
Cable screw direction: From top
Connector screw direction: From top
DCN1-1P
One-branch tap provided with 2 connectors, standard terminating resistor,
and fuse
XW4G-05C1-H1-D
Parallel clamp connector with screws
Connector insertion and wiring both performed horizontally.
XW4G-05C4-TF-D
Parallel multi-branching clamp connector with screws
Connector insertion and wiring performed in same direction.
XW4B-05C1-H1-D
Parallel connector with screws
Connector insertion and wiring performed in same direction.
XW4B-05C4-T-D
Parallel, screw-less, multi-branching connector
Connector insertion and wiring performed in same direction.
XW4B-05C4-TF-D
Parallel, multi-branching connector with screws
Connector insertion and wiring performed in same direction.
XW4B-05C1-V1R-D
Orthogonal connector with screws
Connector insertion and wiring performed at a right angle.
DCA1-5C10 (-B)
Thin cable length: 100 m
DCA1-5C10-B: Cable color: Blue
DCA1-5C10: Cable color: Gray
DCA2-5C10 (-B)
Thick cable length: 100 m
DCA2-5C10-B: Cable color: Blue
DCA2-5C10: Cable color: Gray
DRS1-T
Resistance of 121 Ω
Connectors
DeviceNet Cables
Terminal-block
Terminator
2
Read and Understand This Catalog
Please read and understand this catalog before purchasing the products. Please consult your OMRON representative if you have any questions or
comments.
Warranty and Limitations of Liability
WARRANTY
OMRON's exclusive warranty is that the products are free from defects in materials and workmanship for a period of one year (or other period if specified)
from date of sale by OMRON.
OMRON MAKES NO WARRANTY OR REPRESENTATION, EXPRESS OR IMPLIED, REGARDING NON-INFRINGEMENT, MERCHANTABILITY, OR
FITNESS FOR PARTICULAR PURPOSE OF THE PRODUCTS. ANY BUYER OR USER ACKNOWLEDGES THAT THE BUYER OR USER ALONE HAS
DETERMINED THAT THE PRODUCTS WILL SUITABLY MEET THE REQUIREMENTS OF THEIR INTENDED USE. OMRON DISCLAIMS ALL OTHER
WARRANTIES, EXPRESS OR IMPLIED.
LIMITATIONS OF LIABILITY
OMRON SHALL NOT BE RESPONSIBLE FOR SPECIAL, INDIRECT, OR CONSEQUENTIAL DAMAGES, LOSS OF PROFITS OR COMMERCIAL LOSS
IN ANY WAY CONNECTED WITH THE PRODUCTS, WHETHER SUCH CLAIM IS BASED ON CONTRACT, WARRANTY, NEGLIGENCE, OR STRICT
LIABILITY.
In no event shall the responsibility of OMRON for any act exceed the individual price of the product on which liability is asserted.
IN NO EVENT SHALL OMRON BE RESPONSIBLE FOR WARRANTY, REPAIR, OR OTHER CLAIMS REGARDING THE PRODUCTS UNLESS
OMRON'S ANALYSIS CONFIRMS THAT THE PRODUCTS WERE PROPERLY HANDLED, STORED, INSTALLED, AND MAINTAINED AND NOT
SUBJECT TO CONTAMINATION, ABUSE, MISUSE, OR INAPPROPRIATE MODIFICATION OR REPAIR.
Application Considerations
SUITABILITY FOR USE
OMRON shall not be responsible for conformity with any standards, codes, or regulations that apply to the combination of products in the customer's
application or use of the products.
At the customer's request, OMRON will provide applicable third party certification documents identifying ratings and limitations of use that apply to the
products. This information by itself is not sufficient for a complete determination of the suitability of the products in combination with the end product,
machine, system, or other application or use.
The following are some examples of applications for which particular attention must be given. This is not intended to be an exhaustive list of all possible
uses of the products, nor is it intended to imply that the uses listed may be suitable for the products:
Outdoor use, uses involving potential chemical contamination or electrical interference, or conditions or uses not described in this catalog.
Nuclear energy control systems, combustion systems, railroad systems, aviation systems, medical equipment, amusement machines, vehicles,
safety equipment, and installations subject to separate industry or government regulations.
Systems, machines, and equipment that could present a risk to life or property.
Please know and observe all prohibitions of use applicable to the products.
NEVER USE THE PRODUCTS FOR AN APPLICATION INVOLVING SERIOUS RISK TO LIFE OR PROPERTY WITHOUT ENSURING THAT THE
SYSTEM AS A WHOLE HAS BEEN DESIGNED TO ADDRESS THE RISKS, AND THAT THE OMRON PRODUCTS ARE PROPERLY RATED AND
INSTALLED FOR THE INTENDED USE WITHIN THE OVERALL EQUIPMENT OR SYSTEM.
PROGRAMMABLE PRODUCTS
OMRON shall not be responsible for the user's programming of a programmable product, or any consequence thereof.
Disclaimers
CHANGE IN SPECIFICATIONS
Product specifications and accessories may be changed at any time based on improvements and other reasons.
It is our practice to change model numbers when published ratings or features are changed, or when significant construction changes are made.
However, some specifications of the products may be changed without any notice. When in doubt, special model numbers may be assigned to fix or
establish key specifications for your application on your request. Please consult with your OMRON representative at any time to confirm actual
specifications of purchased products.
DIMENSIONS AND WEIGHTS
Dimensions and weights are nominal and are not to be used for manufacturing purposes, even when tolerances are shown.
PERFORMANCE DATA
Performance data given in this catalog is provided as a guide for the user in determining suitability and does not constitute a warranty. It may represent the
result of OMRON’s test conditions, and the users must correlate it to actual application requirements. Actual performance is subject to the OMRON
Warranty and Limitations of Liability.
ERRORS AND OMISSIONS
The information in this document has been carefully checked and is believed to be accurate; however, no responsibility is assumed for clerical,
typographical, or proofreading errors, or omissions.
2012.9
In the interest of product improvement, specifications are subject to change without notice.
OMRON Corporation
Industrial Automation Company
http://www.ia.omron.com/
(c)Copyright OMRON Corporation 2012 All Right Reserved.
Mouser Electronics
Authorized Distributor
Click to View Pricing, Inventory, Delivery & Lifecycle Information:
Omron:
XW4B-05C4-TF-D