0
登录后你可以
  • 下载海量资料
  • 学习在线课程
  • 观看技术视频
  • 写文章/发帖/加入社区
会员中心
创作中心
发布
  • 发文章

  • 发资料

  • 发帖

  • 提问

  • 发视频

创作活动
Y92H-4

Y92H-4

  • 厂商:

    OMRON(欧姆龙)

  • 封装:

    -

  • 描述:

    CLIP HOLD DOWN FOR PY SOCKET

  • 数据手册
  • 价格&库存
Y92H-4 数据手册
Solid-state Timer H3Y CSM_H3Y_DS_E_4_1 Miniature Timer Compatible with the MY Relay • Semi-multi power supply voltage. • Large transparent time setting knob facilitates time setting. A flat-blade and Phillips screwdriver can also be used for time setting. • Pin configuration compatible with MY Power Relay. • LED indication for power and output statuses. • Conforms to EMC standards. • Conforms to EN61812-1 and approved by UL and CSA. LR Ordering Information Operation/ resetting system Time-limit contact Time ranges Supply voltage Mounting Surface/DIN-track mounting (with socket) Time-limit operation/ DPDT (for power self-resetting switching) 0.04 s to 3 h 4PDT 24, 100 to 120, 200 to 230 VAC H3Y-2 (50/60 Hz); 12, 24, 48, 125, 100 to H3Y-4 (See note 3.) 110 VDC Surface mounting (with PCB terminals) H3Y-2-0 H3Y-4-0 (See note 3.) Note: 1. Specify both the model number, supply voltage, and rated time when ordering. Ex. H3Y-2 100 to 120 VAC 0.5 s Rated time Supply voltage 2. Sockets and Hold-down Clips are not included with the H3Y. They must be ordered separately. 3. Use the H3Y-4 or H3Y-4-0 Series when switching micro loads. ■ Accessories (Order Separately) Adapter, Mounting Plate, Clip Socket Name/specification Timer Model Flush mounting adapter Y92F-78 Mounting Plate for Socket For 1 Socket PYP-1 For 18 Sockets PYP-18 Clip For PYF@A Y92H-3 For PY@ and PYF@M Y92H-4 Contact Square Sockets Model Pin Connection Terminal DIN track mounting DPDT H3Y-2 8-pin H3YN-2@ Back Solder Connecting terminal DIN track mounting 4PDT PYF08A DIN track Front mounting PYF08A-E Connecting (Fingersafe tyape) Screw mounting Note: For details, refer to Safety Precautions. Model PYF08F PY08 PYF14A Front DIN track Connecting mounting H3Y-4 14-pin PYF14A-E H3YN-4@ (Fingersafe tyape) Back Solder Connecting terminal PY14 Note: 1. Cannot be used with the H3Y-@-0 (PCB terminals). 2. The PYF@@A-E has a finger-protection structure. Round crimp terminals cannot be used. Use forked crimp terminals. 3. For details, refer to Socket and DIN Track Products. 1 H3Y Specifications ■ Time Ranges Rated time Time setting range Rated time Time setting range 0.5 s 0.04 to 0.5 s 3 min 0.1 to 3 min 1s 0.1 to 1 s 5 min 0.2 to 5 min 5s 0.2 to 5 s 10 min 0.5 to 10 min 10 s 0.5 to 10 s 30 min 1 to 30 min 30 s 1.0 to 30 s 60 min 2 to 60 min 60 s 2.0 to 60 s 3h 0.1 to 3 h 120 s 5.0 to 120 s --- --- ■ Ratings Item H3Y-2(-0)/H3Y-4(-0) Rated supply voltage (See note 6.) 24, 100 to 120 (50/60 Hz), 200 to 230 VAC (50/60 Hz) (See note 1.), 12, 24, 48, 125, 100 to 110 VDC (See notes 2 and 3.) Operating voltage range All rated voltages except 12 VDC: 85% to 110% of rated supply voltage 12 VDC: 90% to 110% of rated supply voltage (See note 4.) Reset voltage 10% min. of rated supply voltage (See note 5.) Power consumption 100 to 120 VAC: 200 to 230 VAC: 24 VAC: 12 VDC: 24 VDC: 48 VDC: 100 to 110 VDC: 125 VDC: Control outputs Relay ON: Approx. 1.8 VA (1.6 W) at 120 VAC, 60 Hz Relay OFF: Approx. 1 VA (0.6 W) at 120 VAC, 60 Hz Relay ON: Approx. 2.2 VA (1.8 W) at 230 VAC, 60 Hz Relay OFF: Approx. 1.5 VA (1.1 W) at 230 VAC, 60 Hz Relay ON: Approx. 1.8 VA (1.4 W) at 24 VAC, 60 Hz Relay OFF: Approx. 0.3 VA (0.2 W) at 24 VAC, 60 Hz Relay ON: Approx. 1.1 W at 12 VDC Relay OFF: Approx. 0.1 W at 12 VDC Relay ON: Approx. 1.1 W at 24 VDC Relay OFF: Approx. 0.1 W at 24 VDC Relay ON: Approx. 1.2 W at 48 VDC Relay OFF: Approx. 0.3 W at 48 VDC Relay ON: Approx. 1.6 W at 110 VDC Relay OFF: Approx. 0.4 W at 110 VDC Relay ON: Approx. 1.6 W at 125 VDC Relay OFF: Approx. 0.4 W at 125 VDC H3Y-2(-0): 5 A at 250 VAC, resistive load (cosφ = 1) H3Y-4(-0): 3 A at 250 VAC, resistive load (cosφ = 1) Note: 1. 2. 3. 4. Do not use the output from an inverter as the power supply. Refer to Safety Precautions for All Times for details. With DC ratings, single-phase full-wave rectified power sources may be used. Only the H3Y-2 and H3Y-2-0 Series include 2-VDC models. Use the Timer within 90% to 110% of the rated supply voltage (95% to 110% for 12 VDC) when using it continuously under an ambient operating temperature of 50°C. 5. Set the reset voltage as follows to ensure proper resetting. 100 to 120 VAC:10 VAC max. 200 to 230 VAC:20 VAC max. 100 to 110 VDC:10 VDC max. 6. Refer to Safety Precautions for All Times when combining the Timer with an AC 2-wire proximity sensor. 2 H3Y ■ Characteristics Accuracy of operating time ±1% FS max. (0.5 s range: ±1%±10 ms max.) Setting error (see note 1) ±10%±50 ms FS max. Reset time Min. power-opening time: 0.1 s max. (including halfway reset) Reset voltage 10% max. of rated supply voltage Influence of voltage (see note 1) ±2% FS max. Influence of temperature (see note 1) ±2% FS max. Insulation resistance 100 MΩ min. (at 500 VDC) Dielectric strength 2,000 VAC, 50/60 Hz for 1 min (between current-carrying terminals and exposed non-current-carrying metal parts) (see note 2) 2,000 VAC, 50/60 Hz for 1 min (between operating power circuit and control output) (see note 2) 2,000 VAC, 50/60 Hz for 1 min (between different pole contacts; 2-pole model) (see note 2) 1,500 VAC, 50/60 Hz for 1 min (between different pole contacts; 4-pole model) 1,000 VAC, 50/60 Hz for 1 min (between non-continuous contacts) Vibration resistance Destruction: 10 to 55 Hz, 0.75-mm single amplitude Malfunction: 10 to 55 Hz, 0.5-mm single amplitude Shock resistance Destruction: 1,000 m/s2 (approx. 100G) Malfunction: 100 m/s2 (approx. 10G) Ambient temperature Operating: Storage: –10°C to 50°C (with no icing) –25°C to 65°C (with no icing) Ambient humidity Operating: 35% to 85% Life expectancy Mechanical:10,000,000 operations min. (under no load at 1,800 operations/h) Electrical: H3Y-2: 500,000 operations min. (5 A at 250 VAC, resistive load at 1800 operations/h) H3Y-4: 200,000 operations min. (3 A at 250 VAC, resistive load at 1800 operations/h) Impulse withstand voltage Between power terminals: 3 kV for 100 to 120 VAC, 200 to 230 VAC, 100 to 110 VDC, 125 VDC 1 kV for 12 VDC, 24 VDC, 48 VDC Between exposed non-current-carrying metal parts: 4.5 kV for 100 to 120 VAC, 200 to 230 VAC, 100 to 110 VDC, 125 VDC 1.5 kV for 12 VDC, 24 VDC, 48 VDC Noise immunity ±1.5 kV, square-wave noise by noise simulator (pulse width: 100 ns/1 μs, 1-ns rise) Static immunity Destruction: 8 kV Malfunction: 4 kV Enclosure rating IP40 Weight Approx. 50 g EMC (EMI) EN61812-1 Emission Enclosure: EN55011 Group 1 class A Emission AC Mains: EN55011 Group 1 class A (EMS) EN61812-1 Immunity ESD: EN61000-4-2: 8 kV air discharge (level 3) Immunity RF-interference from AM Radio Waves: EN61000-4-3: 10 V/m (80 MHz to 1 GHz) (level 3) Immunity Burst: EN61000-4-4: 2 kV power-line (level 3) 2 kV I/O signal-line (level 4) Immunity Surge: EN61000-4-5: 2 kV line to ground (level 3) 1 kV line to line (level 3) Approved standards UL508, CSA C22.2 No. 14, Lloyds Conforms to EN61812-1 and IEC60664-1. (2.5 kV/2 for H3Y-2/-2-0, 2.5 kV/1 for H3Y-4/-4-0) Output category according to EN60947-5-1. Note: 1. Add ±10 mS to the above value for the 0.5-S range model. 2. Terminal screw sections are excluded. 3 H3Y Engineering Data H3Y-2, H3Y-2-0 Switching operations (×103) 250 VAC, cosφ = 1 24 VDC, cosφ = 1 Switching operations (×103) H3Y-2, H3Y-2-0 Load current (A) 250 VAC, cosφ = 0.4 24 VDC, L/R = 7 ms Load current (A) Reference: A maximum current of 0.6 A can be switched at 125 VDC (cosφ = 1). Maximum current of 0.2 A can be switched if L/R is 7 ms. In both cases, a life of 100,000 operations can be expected.The minimum applicable load is 1 mA at 5 VDC (P reference value). H3Y-4, H3Y-4-0 250 VAC, cosφ = 1 24 VDC, cosφ = 1 Load current (A) Switching operations (×103) Switching operations (×103) H3Y-4, H3Y-4-0 250 VAC, cosφ = 0.4 24 VDC, L/R = 7 ms Load current (A) Reference: A maximum current of 0.5 A can be switched at 125 VDC (cosφ = 1). Maximum current of 0.2 A can be switched if L/R is 7 ms. In both cases, a life of 100,000 operations can be expected.The minimum applicable load is 1 mA at 1 VDC (P reference value). Operation ■ Timing Chart H3Y-2, H3Y-2-0 NC H3Y-4, H3Y-4-0 NC 4 H3Y Dimensions Note: All units are in millimeters unless otherwise indicated. ■ Timers H3Y-2 H3Y-4 28 max. 28 max. 6.3 6.3 6.4 21.5 max. 6.4 21.5 max. (63.0) (63.0) H3Y-2-0 H3Y-4-0 28 max. 28 max. 6.3 6.3 21.5 max. (60.7) 21.5 max. (60.7) Mounting Holes Pin 1 Mounting Holes Pin 1 Eight, 1.3-dia. holes Fourteen, 1.3-dia. holes 5 H3Y ■ Accessories (Order Separately) Use the PYF@A, PY@, PY@-02, or PY@QN(2) to mount the H3Y. When ordering any one of these sockets, replace “@” with “08” or “14.” Track Mounting/Front Connecting Sockets PYF08A Two, 4.2 × 5 mounting holes Eight, M3 × 8 sems 6 Terminal Arrangement (Top View) 3.4 Mounting Holes Two, 4.5 dia. M4 or M3 H3Y Series 35.4 72 max. 90.5 86.6 59±0.3 4 PYF@A 6 23 max. 15±0.2 16.5 30 max. PYF14A Two, 4.2 × 5 mounting holes Terminal Arrangement (Top View) 3.4 6 Fourteen, M3 × 8 sems Mounting Holes Two, 4.5 dia. M4 or M3 35.4 72 max. 59±0.3 4 29.5 max. 22±0.2 6 16.5 30 max. PYF08A-N Terminal Arrangement 22 max. 4 1 42 12 8 5 44 14 42 4 44 8 Mounting Holes (for Surface Mounting) 12 1 14 5 3.2 dia. 66.5 max. 3.6 dia. 19.8 PYF-08A-N 41 11 12 9 9 12 41 A2 A2 A1 14 14 13 11 14 14 13 A2 A2 A1 30 max. PYF14A-N Terminal Arrangement 4 3 2 1 42 32 22 12 8 7 6 5 44 34 24 14 42 4 44 8 32 3 34 7 22 2 24 6 12 1 14 5 Mounting Holes (for Surface Mounting) Two, 3.5 dia. 66.5 max. PYF-14A-N 41 31 21 12 11 10 A2 A2 A1 11 14 14 13 9 30 max. 29.5 max. 12 11 10 9 41 31 21 11 13 14 14 A2 A2 20.8 A1 6 H3Y PYF08A-E Two, 4.2 × 5 mounting holes (Top View) Two, 4.5 dia. M4 or M3 Eight, M3 × 8 sems 72 max. 23 max. 31 max. PYF14A-E (Top View) Two, 4.2 × 5 mounting holes Two, 4.5 dia. M4 or M3 Eight, M3 × 8 sems 72 max. 29.5 max. 31 max. Back Connecting Sockets PY08, PY14 Terminal Arrangement (Bottom View) Eight, 3 × 1.2 dia. holes only for PY08 (Fourteen, 3 × 1.2 dia. holes) 24 max. 0.3 2.7 21.4+0.2 0 25.5 29.5 max. max. 59.3 H3Y Series 25.8+0.2 0 2.6 7.7 PY08 20 max. Terminal Arrangement (Bottom View) 24 max. 22 max. 25 max. * (See note) PY14 PY@, PY@-02, PY@QN(2) PY08QN, PY14QN PY08QN(2), PY14QN(2) 2.7 Panel Cutout 29.5 max. 1×1 ** 41.5 max. (see note) Note: With PY@QN(2), dimension * should read 20 max. and dimension ** 36.5 max. PY08-02, PY14-02 4.3 2.7 PY14QN PY14QN(2) Terminal Arrangement (Bottom View) 22 max. 0.3 PY08QN PY08QN(2) 25.5 29.5 max. max. 2 16.5 max. PY08-02 PY14-02 7 H3Y Socket Mounting Plates (t = 1.6) Applicable socket PY08, PY14, PY08QN(2), PY14QN(2) For mounting 1 socket PYP-1 For mounting 18 sockets PYP-18 Note: PYP-18 may be cut to any desired length. PYP-1 PYP-18 Two, 3.4-dia. holes Relay Hold-down Clips Y92H-3 for PYF@A Socket (Set of Two Clips) Mounting Track End Plate PFP-100N/PFP-50N (see note 1) PFP-M Y92H-4 for PY@ Socket 1000 (500) (See note 2) Note: 1. Meets DIN EN50022 2. This dimension applies to PFP-50N. Spacer PFP-S 8 H3Y Installation ■ Connection H3Y-2, H3Y-2-0 H3Y-4, H3Y-4-0 Connect the DC power supply to terminals 13 and 14 according to the polarity marks. (Bottom View) Connect the DC power supply to terminals 13 and 14 according to the polarity marks. (Bottom View) 9 H3Y Safety Precautions Refer to Safety Precautions for All Timers. Lead Wire Screw Connections Precautions for Safe Use Tighten lead wire screws to the following torque. PYF socket: 0.78 to 1.18 N·m The values are recommended when crimp terminals are used. If the screws connecting a panel-mounting socket are not sufficiently tightened, the lead wire can become detached and abnormal heating or fire can be caused by the contact failure. Conversely, excessive tightening can strip the threads. Confirm that the setting dial, indicators and plastic parts are operating normally. Depending on the operating environment, the setting dial, indicators and plastic parts may deteriorate faster than expected, causing the indicators to fail. Periodically perform inspections and replacements. Precautions for Correct Use When selecting a control output, use the H3Y-2 for switching ON and OFF the power and the H3Y-4 for switching ON and OFF the minute load. The operating voltage will increase when using the H3Y in any place where the ambient temperature is more than 50°C. Supply 90% to 110% of the rated voltages (at 12 VDC: 95% to 110%) when operating at 45°C or higher. Do not leave the H3Y in time-up condition for a long period of time (for example, more than one month in any place where the ambient temperature is high), otherwise the internal parts (aluminum electrolytic capacitor) may become damaged. Therefore, the use of the H3Y with a relay as shown in the following circuit diagram is recommended to extend the service life of the H3Y. Use the same type of wiring for all Timer wiring. When disposing of the Timer, observe all local ordinances as they apply. Connect the DC power supply to terminals 13 and 14 according to the polarity marks. Precautions for EN61812-1 Conformance The H3Y as a built-in timer conforms to EN61812-1 provided that the following conditions are satisfied. Handling Before dismounting the H3Y from the socket, make sure that no voltage is imposed on any terminal of the H3Y. Wiring The power supply for the H3Y must be protected with equipment such as a breaker approved by VDE. Basic insulation is ensured between the H3Y’s operating circuit and control output. Auxiliary relay such as MY Relay Do not connect the H3Y as shown in the following circuit diagram on the right hand side, otherwise the H3Y’s internal contacts different from each other in polarity may become short-circuited. Correct Insulation requirement: Overvoltage category II, pollution degree 1 (H3Y-4/-4-0), pollution degree 2 (H3Y-2/-2-0) (with a clearance of 1.5 mm and a creepage distance of 2.5 mm at 240 VAC) Output terminals next to each other on the H3Y-4 or H3Y-4-0 must have the same polarity. Incorrect L2 L1 L2 L1 Use the following safety circuit when building a self-holding or selfresetting circuit with the H3Y and an auxiliary relay, such as an MY Relay, in combination. : H3Y Auxiliary relay: MY Relay Do not use the H3Y in places where there is excessive dust, corrosive gas, or direct sunlight. Do not mount more than one H3Y closely together, otherwise the internal parts may become damaged. Make sure that there is a space of 5 mm or more between any H3Y Models next to each other to allow heat radiation. The internal parts may become damaged if a supply voltage other than the rated ones is imposed on the H3Y. When more than 100 V is applied to 12- or 24-VDC models, the internal element (varistor) may break. ALL DIMENSIONS SHOWN ARE IN MILLIMETERS. To convert millimeters into inches, multiply by 0.03937. To convert grams into ounces, multiply by 0.03527. In the interest of product improvement, specifications are subject to change without notice. 10 Read and Understand This Catalog Please read and understand this catalog before purchasing the products. Please consult your OMRON representative if you have any questions or comments. Warranty and Limitations of Liability WARRANTY OMRON's exclusive warranty is that the products are free from defects in materials and workmanship for a period of one year (or other period if specified) from date of sale by OMRON. OMRON MAKES NO WARRANTY OR REPRESENTATION, EXPRESS OR IMPLIED, REGARDING NON-INFRINGEMENT, MERCHANTABILITY, OR FITNESS FOR PARTICULAR PURPOSE OF THE PRODUCTS. ANY BUYER OR USER ACKNOWLEDGES THAT THE BUYER OR USER ALONE HAS DETERMINED THAT THE PRODUCTS WILL SUITABLY MEET THE REQUIREMENTS OF THEIR INTENDED USE. OMRON DISCLAIMS ALL OTHER WARRANTIES, EXPRESS OR IMPLIED. LIMITATIONS OF LIABILITY OMRON SHALL NOT BE RESPONSIBLE FOR SPECIAL, INDIRECT, OR CONSEQUENTIAL DAMAGES, LOSS OF PROFITS OR COMMERCIAL LOSS IN ANY WAY CONNECTED WITH THE PRODUCTS, WHETHER SUCH CLAIM IS BASED ON CONTRACT, WARRANTY, NEGLIGENCE, OR STRICT LIABILITY. In no event shall the responsibility of OMRON for any act exceed the individual price of the product on which liability is asserted. IN NO EVENT SHALL OMRON BE RESPONSIBLE FOR WARRANTY, REPAIR, OR OTHER CLAIMS REGARDING THE PRODUCTS UNLESS OMRON'S ANALYSIS CONFIRMS THAT THE PRODUCTS WERE PROPERLY HANDLED, STORED, INSTALLED, AND MAINTAINED AND NOT SUBJECT TO CONTAMINATION, ABUSE, MISUSE, OR INAPPROPRIATE MODIFICATION OR REPAIR. Application Considerations SUITABILITY FOR USE OMRON shall not be responsible for conformity with any standards, codes, or regulations that apply to the combination of products in the customer's application or use of the products. At the customer's request, OMRON will provide applicable third party certification documents identifying ratings and limitations of use that apply to the products. This information by itself is not sufficient for a complete determination of the suitability of the products in combination with the end product, machine, system, or other application or use. The following are some examples of applications for which particular attention must be given. This is not intended to be an exhaustive list of all possible uses of the products, nor is it intended to imply that the uses listed may be suitable for the products:  Outdoor use, uses involving potential chemical contamination or electrical interference, or conditions or uses not described in this catalog.  Nuclear energy control systems, combustion systems, railroad systems, aviation systems, medical equipment, amusement machines, vehicles, safety equipment, and installations subject to separate industry or government regulations.  Systems, machines, and equipment that could present a risk to life or property. Please know and observe all prohibitions of use applicable to the products. NEVER USE THE PRODUCTS FOR AN APPLICATION INVOLVING SERIOUS RISK TO LIFE OR PROPERTY WITHOUT ENSURING THAT THE SYSTEM AS A WHOLE HAS BEEN DESIGNED TO ADDRESS THE RISKS, AND THAT THE OMRON PRODUCTS ARE PROPERLY RATED AND INSTALLED FOR THE INTENDED USE WITHIN THE OVERALL EQUIPMENT OR SYSTEM. PROGRAMMABLE PRODUCTS OMRON shall not be responsible for the user's programming of a programmable product, or any consequence thereof. Disclaimers CHANGE IN SPECIFICATIONS Product specifications and accessories may be changed at any time based on improvements and other reasons. It is our practice to change model numbers when published ratings or features are changed, or when significant construction changes are made. However, some specifications of the products may be changed without any notice. When in doubt, special model numbers may be assigned to fix or establish key specifications for your application on your request. Please consult with your OMRON representative at any time to confirm actual specifications of purchased products. DIMENSIONS AND WEIGHTS Dimensions and weights are nominal and are not to be used for manufacturing purposes, even when tolerances are shown. PERFORMANCE DATA Performance data given in this catalog is provided as a guide for the user in determining suitability and does not constitute a warranty. It may represent the result of OMRON’s test conditions, and the users must correlate it to actual application requirements. Actual performance is subject to the OMRON Warranty and Limitations of Liability. ERRORS AND OMISSIONS The information in this document has been carefully checked and is believed to be accurate; however, no responsibility is assumed for clerical, typographical, or proofreading errors, or omissions. 2011.10 In the interest of product improvement, specifications are subject to change without notice. OMRON Corporation Industrial Automation Company http://www.ia.omron.com/ (c)Copyright OMRON Corporation 2011 All Right Reserved. Mouser Electronics Authorized Distributor Click to View Pricing, Inventory, Delivery & Lifecycle Information: Omron: Y92H-4
Y92H-4 价格&库存

很抱歉,暂时无法提供与“Y92H-4”相匹配的价格&库存,您可以联系我们找货

免费人工找货