0
登录后你可以
  • 下载海量资料
  • 学习在线课程
  • 观看技术视频
  • 写文章/发帖/加入社区
创作中心
发布
  • 发文章

  • 发资料

  • 发帖

  • 提问

  • 发视频

创作活动
NCP1075SOTGEVB

NCP1075SOTGEVB

  • 厂商:

    ONSEMI(安森美)

  • 封装:

    -

  • 描述:

    NCP1075 - AC/DC, Primary Side 1, Isolated Outputs Evaluation Board

  • 数据手册
  • 价格&库存
NCP1075SOTGEVB 数据手册
Test Procedure for the NCP1075SOTGEVB Evaluation Board Introduction: The NCP1075 EVAL demo board is a universal input, off-line, 10 watt output, constant voltage power supply for powering E-meters or white goods applications. The output can be configured easily with a few component changes for 12Vout or 5Vout. The switching topology is a discontinuous mode flyback converter utilizing the ON Semi NCP1075 monolithic controller with internal MOSFET. The specific default demo board has an output rating of 12 volts at 0.8 amps max. Info for modification and testing for a 5Vout board is below. Equipment Required: 1. Adjustable, isolated AC power source capable of zero to 265 Vac output up to 500 mA. AC source should have the capability of measuring input power in watts. If not, an AC line analyzer or AC wattmeter should be used. Wattmeter should be capable if reading down to 50 mW (for standby power measurements.) 2. Digital volt/amp meters to measure output current and voltage to the electronic load. 3. A variable electronic load or rheostat capable of up to a 3 amp load. If an electronic load is used it is preferable to have a constant resistance load mode. The current meter on the electronic load can be used in lieu of a series, in-line ammeter. 4. Oscilloscope with probe to monitor output ripple on the demo converter. 5/22/2012 -1- www.onsemi.com Setup Procedure: Set the equipment as shown in the diagram below so that the output voltage and current to the demo board can be measured and the output ripple can be monitored. AC Source volts 115 Vac DVM - + AC out Vadj Iaj O'scope Board Under Test WATTS (Required if not in AC source) AC in + DC out Electronic Load amps + DVM - + Adj Note: Indicated output polarity on above drawing of demo board may not correspond to actual demo board. Please note output polarity as marked on demo board. Test Procedure: 1. Switch the electronic load on and set to zero load; switch all of the digital meters on (assuming they are wired properly for voltage and current sensing); turn the oscilloscope on with sensing in AC mode and 100 mV per division vertical and a sweep rate of 5 uS per division. Connect the scope probe to the demo board’s output terminals. 2. With the AC source OFF, set the current limit on the AC source to 250 mA and the output voltage to 120 Vac. 3. Turn on the AC source and the power supply output voltage should be 12 Vdc + 0.3 V, - 0.2V on the DVM (11.8 to 12.3 V is default output voltage setup for this demo board). 4. Adjust the electronic load from no load slowly up to 0.8A (full load). The output voltage should remain within 120 mV (1%) of nominal if properly regulating. The output ripple (switching frequency) on the oscilloscope should be less than 150 mV peak-to-peak at full load. (Note – scope probe tip should be decoupled with a 5/22/2012 -2- www.onsemi.com 0.1uF ceramic capacitor and ground wire should not be used to get best accuracy and max attenuation of switching noise pickup.) 5. Adjust the AC source down to 90 Vac and the power supply output should still be in spec. Return the AC source to 120 Vac. 6. While at full load, check the efficiency. Effic = (Vout x Iout)/Pin. It should be greater than 76%. 7. Continue to increase the load slowly and the over-current protection should kick in between 1 and 2 amps. This should result in a “hick-up” start-stop type of operation or a de-regulation of Vout below nominal, particularly with 240Vac input. 8. Set the load back to 0.8 amps and the power supply should recover with proper output voltage. 9. Adjust the electronic load to back to zero (do not switch it off!) and check the input power (standby power). It should be below 100 mW (note: this may not be measurable with test equipment when supply in skip mode.) 10. Adjust the AC input to 230 Vac and repeat tests (3) through (8) with the exception of (5). 11. Switch the AC source off and disconnect the demo board. End of Test. Parts Change for 5Vout Version (See BOM) from 12V Board: Vout set: R6 to 240 ohms; R8 to 21.5K Output Rectifier: D7 to MBRS2040L Transformer: T1 to Wurth #750312596 Test Parameter Limits for 5Vout demo board: Vout nominal = 5.0V +/- 100mV; ripple < 200mV Full load = 2.0 amps Efficiency = > 75% (at full load) Overcurrent = 2.5 to 3.8 amps Standby power = < 100 mW 5/22/2012 -3- www.onsemi.com
NCP1075SOTGEVB 价格&库存

很抱歉,暂时无法提供与“NCP1075SOTGEVB”相匹配的价格&库存,您可以联系我们找货

免费人工找货