Test Procedure for the NCP1236 Demoboard
NCP1236B65NBGEVB
05/31/2011
Required Equipment:
Current limited 90 ÷ 265 Vrms AC source (current limited to avoid board destruction in
case of defective part) (e.g. AGILENT 6811) ……………………………...…… 1pc
AC Volt-Meter able to measure up to 300 V AC (e.g. KEITHLEY 2000) ….… 1pc
AC Amp-Meter able to measure up to 3 A AC (e.g. KEITHLEY 2000) …….... 1pc
DC Amp-Meter able to measure up to 5 A DC (e.g. FLUKE 89 IV)……….….
1pc
DC Volt-Meter able to measure up to 30 V DC (e.g. KEITHLEY 2000) …...… 1pc
DC Electronic Load (e.g. AGILENT 6060B) …………………………………... 1pc
A
V
A
AC source
90 ÷ 265 Vac
V
Figure 1: Test Setup
The following steps describe the test procedure for all these boards:
Test Procedure:
1. Connect the test setup as shown in Figure 1.
2. Apply an input voltage, VIN = 90 ÷ 265 Vac
3. Apply IOUT(load) = 0 A
4. Check that VOUT = 19 Vdc
5. Set IOUT to 3.5 A
6. Check that VOUT = 19 Vdc
7. Turn off the load
8. Turn off VIN
9. End of the test
Be careful when manipulating the boards in operation, lethal voltages up to 425V are
present on the primary side. An isolation transformer is also recommended for safer
manipulations.