Test Procedure for the NCP702MX28TCGEVB Evaluation
Board
04-JUN-12
Test Setup 1:
Electronic
Electronic
Power Supply
- VIN
Load
+ VIN
VOLTMETER2
+ VOUT
- VOUT
V
V
VOLTMETER1
Figure 1. Test setup for the measurements of basic regulation
characteristics
Required Equipment:
2 x Voltmeters
DC Power Supply – Max. 5.5V
Electronic Load
5/14/2012
-1-
www.onsemi.com
Test Procedure for the Measurement of Line Regulation parameter
using Test Setup 1:
1. Connect the test setup as shown on Figure 1,
2. Set the electronic load for the required load current e.g. IOUT = 10mA,
3. Apply the required minimum input voltage e.g. VIN_MIN = VOUT_NOM + 0.3V (1),
4. Note the output voltage reading VOUT1 indicated by VOTLMETER2,
5. Apply the required maximum input voltage e.g. VIN_MAX = VOUT_NOM + 1.3V (1),
6. Note the output voltage reading VOUT2 indicated by VOTLMETER2,
7. Calculate the Line Regulation parameter as:
RegLINE = (VOUT2 – VOUT1) / (VIN_MAX – VIN_MIN) [V/V]
8. Turn off the electronic load. Turn off the input power supply,
9. End of the test.
Test Procedure for the Measurement of Load Regulation parameter
using Test Setup 1:
1. Connect the test setup as shown on Figure 1,
2. Set the electronic load for the required minimum output current e.g. IOUT_MIN = 1mA,
3. Apply the desired input voltage e.g. VIN = VOUT_NOM + 0.3V (1),
4. Note the output voltage reading VOUT1 indicated by VOTLMETER2,
5. Set the electronic load for the required maximum output current e.g. IOUT_MAX =
150mA,
6. Note the output voltage reading VOUT2 indicated by VOTLMETER2,
7. Calculate the Load Regulation parameter as:
RegLOAD = (VOUT2 – VOUT1) / (IOUT_MAX – IOUT_MIN) [V/A]
5. Turn off the electronic load. Turn off the input power supply,
6. End of the test.
(1)
VOUT_NOM is the nominal output voltage level of the regulator. NCP702 operating
VIN must be in the range 2.0V ≤ VIN ≤ 5.5V
5/14/2012
-2-
www.onsemi.com
Test Setup 2:
Oscilloscope
Square Pulse
Generator
- VEN
CH1
CH2
+ VEN
Electronic
Electronic
Power Supply
Load
- VIN
+ VIN
+ VOUT
- VOUT
V
VOLTMETER1
Figure 2. Test setup for the measurements of the Enable functionality
Required Equipment:
DC Power Supply – Max. 5.5V
Electronic Load, Voltmeter, Oscilloscope
5/14/2012
-3-
www.onsemi.com
Test Procedure for the measurements of the Enable functionality
using Test Setup 2:
1. Connect the test setup as shown on Figure 2,
2. Apply the required input voltage e.g. VIN = VOUT_NOM + 0.3V (1)
3. Set the electronic load for the required load current e.g. IOUT = 10mA,
4. Set the square wave generator to generate the following pulse
waveform:
5. Verify with the oscilloscope that the output voltage VOUT turns ON/OFF.
6. Turn off the pulse generator.
7. Turn off the electronic load.
8. Turn off the input power supply
9. End of the test
(1)
VOUT_NOM is the nominal output voltage level of the regulator. NCP702 operating VIN
must be in the range 2.0V ≤ VIN ≤ 5.5V
5/14/2012
-4-
www.onsemi.com
Test Setup 3:
Electronic
Power Supply
- VIN
+ VIN
A
V
NANOAMP
METER
VOLTMETER2
V
VOLTMETER1
Figure 3. Test setup for the measurements of the disable current
Required Equipment:
DC Power Supply – Max. 5.5V
2 x Voltmeter, Nanoampere meter
5/14/2012
-5-
www.onsemi.com
Test Procedure for the measurements of the disable current using
Test Setup 3:
1. Connect the test setup as shown on Figure 3,
2. Apply the required input voltage e.g. so that Voltmeter1 indicates VIN =
VOUT_NOM + 0.3V (1)
3. Verify that the output voltage measured by Voltmeter2 is very close to
0V,
4. Read the disable current measured by the nanoampere meter.
5. Turn off the input power supply
6. End of the test
(1)
VOUT_NOM is the nominal output voltage level of the regulator. NCP702 operating VIN
must be in the range 2.0V ≤ VIN ≤ 5.5V.
5/14/2012
-6-
www.onsemi.com
很抱歉,暂时无法提供与“NCP702MX28TCGEVB”相匹配的价格&库存,您可以联系我们找货
免费人工找货