Test Procedure for the NCP729FC28GEVB Evaluation Board
10-MAY-2012
Test Setup 1:
Figure 1. Test setup for the measurements of basic regulation
characteristics
Required Equipment:
2 x Voltmeters
2 x Ampere meters
DC Power Supply – Max. 5.5V
Electronic Load
Test Procedure for the Measurement of Line Regulation parameter using
Test Setup 1:
1. Connect the test setup as shown on Figure 1
2. Set the electronic load for the required load current e.g. IOUT = 10mA
3. Apply the required minimum input voltage e.g. VIN_MIN = VOUT_NOM + 0.3V (1)
6/11/2012
-1-
www.onsemi.com
4. Note the output voltage reading VOUT1 indicated by VOTLMETER2
5. Apply the required maximum input voltage e.g. VIN_MAX = VOUT_NOM + 1.3V (1)
6. Note the output voltage reading VOUT2 indicated by VOTLMETER2,
7. Calculate the Line Regulation parameter as:
RegLINE = (VOUT2 – VOUT1) / (VIN_MAX – VIN_MIN) [V/V]
8. Turn off the electronic load. Turn off the input power supply
9. End of the test
Test Procedure for the Measurement of Load Regulation parameter using
Test Setup 1:
1. Connect the test setup as shown on Figure 1
2. Set the electronic load for the required minimum output current e.g. IOUT_MIN =
1mA
3. Apply the desired input voltage e.g. VIN = VOUT_NOM + 0.3V (1)
4. Note the output voltage reading VOUT1 indicated by VOTLMETER2
5. Set the electronic load for the required maximum output current e.g. IOUT_MAX
= 150mA
6. Note the output voltage reading VOUT2 indicated by VOTLMETER2
7. Calculate the Load Regulation parameter as:
RegLOAD = (VOUT2 – VOUT1) / (IOUT_MAX – IOUT_MIN) [V/A]
8. Turn off the electronic load. Turn off the input power supply
9. End of the test
(1) VOUT_NOM is the nominal output voltage level of the regulator. NCP729 operating VIN must be in the
range 2.0V ≤ VIN ≤ 5.5V
6/11/2012
-2-
www.onsemi.com