Multi-rate OC-48/STM-16 LR-2/L-16.2 SFP DWDM Transceivers with Digital Diagnostics
TRPW48L2/E2 DWDM
Product Description The TRPW48L2/E2 DWDM SFP series of multi-rate fiber optic transceivers with digital diagnostics monitoring functionality provide a quick and reliable interface for long reach applications. Diagnostics monitoring functionality (alarm and warning features) is integrated into the design via an I2C serial interface per the Multi-Source Agreement (MSA) on DWDM SFP transceivers (Rev. 1.0, October 2005). Products under this series are compatible with SONET/SDH standards for OC-48/STM-16 (2.67Gb/s) Forward Error Correction and OC-48/STM-16 (2.488Gb/s) LR-2/L-16.2 long reach applications, OC-3/STM-1 (156Mb/s) and OC-12/STM-4 (622Mb/s) SR/I-1 and I-4 short reach applications; Gigabit Ethernet LX (1.25Gb/s) applications per IEEE 802.3; and Fibre Channel 200-SM-LC-L (2.125Gb/s) and 100-SMLC-L (1.062Gb/s) applications per FC-PI standards. The transmitter incorporates a highly reliable 1550nm DFB laser with an operating wavelength in full compliance with 100GHz (0.8nm) spacing per ITU-grid. All transceivers are Class I Laser products per U.S. FDA/CDRH and international IEC-60825 standards. The TRPW48L2/E2 DWDM transceivers connect to standard 20-pad SFP connectors for hot plug capability. This allows the system designer to make configuration changes or maintenance by simply plugging in different types of transceivers without removing the power supply from the host system. The transceivers have blue bail-type latches, which offer an easy and convenient way to release the modules. The latch is compliant with the SFP MSA. The transmitter and receiver DATA interfaces are AC-coupled internally. LV-TTL Transmitter Disable control input and Loss of Signal (LOS) output interfaces are also provided. The transceivers operate from a single +3.3V power supply over an operating case temperature range of -5°C to +70°C (Commercial) or -5°C to +85°C (Extended). The housing is made of metal designed for optimum thermal performance and electromagnetic compatibility. Absolute Maximum Ratings
Parameter Storage Temperature Operating Case Temperature1 Supply Voltage Maximum Input Optical Power (30 seconds max.) Input Voltage
1
Features Compliant with DWDM SFP MSA Multi-rate Operations from 125Mb/s to 2.67Gb/s Support 2.67Gb/s OC-48 FEC Rate 1550nm DFB Laser Transmitter & APD Receiver Long Haul Transmission Distance of 80km or 120km Compliant with G.692 100GHz Channel Spacing Optical Link Power Budget of 28dB Minimum Digital Diagnostics through Serial Interface Internal Calibration for Digital Diagnostics Eye Safe (Class I Laser Safety) Hot-pluggable TX Fault & Loss of Signal Outputs TX Disable Input Temperature option of -5°C to +85°C
Symbol TST Commercial Extended TOP VCC Pin, max VIN
Minimum - 40 -5 -5 0 0
Maximum + 85 + 70 + 85 + 4.5 + 3.0 VCC
Units °C °C V dBm V
Measured on top side of SFP module at the front center vent hole of the cage.
An Oplink Company
Rev7.2008.07.17
TRPW48L2/E2 DWDM
Transmitter Performance Characteristics
All parameters guaranteed only at typical data rate Parameter1 Operating Data Rate Average Optical Output Power (coupled into single mode fiber), 50% duty cycle Extinction Ratio Center Wavelength
2 3
(Over Operating Case Temperature. VCC = 3.13 to 3.47V)
Symbol B PO Phi /Plo λC Δλ20 POFF SMSR t r , tf RIN OC-48 JG -
Minimum 0.125 0 8.2 30 -
Typical -
Maximum 2.67 + 4.0 0.4 - 45.0 0.16 - 117 0.07 2.0 2.0
Units Gb/s dBm dB nm dBm dB ns dB/Hz UIp-p dB
see Ordering Information Table -
Spectral Width (-20dB)
Optical Output Power of OFF Transmitter Side Mode Suppression Ratio Optical Rise/Fall Time (20% to 80%) Relative Intensity Noise Jitter Generation Dispersion Penalty4 Optical Output Eye
1 2
1600ps/nm (80km) 2400ps/nm (120km)
Compliant with Telcordia GR-253-CORE and ITU-T Recommendation G.957
Specified through EOL. BOL: +/-0.05nm from ITU grid. EOL: +/-0.1nm from ITU grid. 3 Measured with OSA and 0.1nm resolution bandwidth. 4 Corresponds to the approximate worst-case dispersion for G.652/G.654 fiber over the center wavelength range of 1528.77-1563.86nm.
Receiver Performance Characteristics
All parameters guaranteed only at typical data rate Parameter1 Operating Data Rate Receiver Sensitivity (10 -10 BER) 2 Receiver Sensitivity (10 -12 BER) 3 OC-3/12/48, 2.67Gb/s 2.125Gb/s, 1.25Gb/s, 1.062Gb/s, 0.125Gb/s Increasing Light Input Decreasing Light Input Increasing Light Input Decreasing Light Input
(Over Operating Case Temperature. VCC = 3.13 to 3.47V) Symbol B Pmin Pmin Pmax Plos+ Plost_loss_off t_loss_on λ Minimum 0.125 - 28.0 - 28.0 - 8.0 - 45.0 2.3 0.5 1260 Typical 1.5 Maximum 2.67 - 28.0 100 100 1570 -27.0 Units Gb/s dBm dBm dBm dBm µs dB nm dB
Maximum Input Optical Power (10-12 BER) LOS Thresholds LOS Timing Delay LOS Hysteresis Wavelength of Operation Receiver Reflectance
1 2 3
Specified through EOL. Measured with 223-1 PRBS. Measured with 27-1 PRBS.
Laser Safety: All transceivers are Class I Laser products per FDA/CDRH and IEC-60825 standards. They must be operated under specified operating conditions.
Oplink Communications, Inc.
DATE OF MANUFACTURE: This product complies with 21 CFR 1040.10 and 1040.11 Meets Class I Laser Safety Requirements
Oplink Communications, Inc.
2
Rev7.2008.07.17
TRPW48L2/E2 DWDM
Transmitter Performance Characteristics
Parameter Input Voltage Swing (TD+ & TD-) 1 Input HIGH Voltage (TX Disable)
2
(Over Operating Case Temperature. VCC = 3.13 to 3.47V) Minimum 0.35 2.0 0 2.0 0 Typical Maximum 1.75 VCC 0.8 VCC + 0.3 0.8 Units V V V V V
Symbol VPP-DIF VIH VIL VOH VOL
Input LOW Voltage (TX Disable) 2 Output HIGH Voltage (TX Fault) 3 Output LOW Voltage (TX Fault)
1 2 3
3
Differential peak-to-peak voltage. There is an internal 4.7 to 10kΩ pull-up resistor to VccT. Open collector compatible, 4.7 to 10kΩ pull-up resistor to Vcc (Host Supply Voltage).
Receiver Electrical Interface
Parameter Output Voltage Swing (RD+ & RD-) 1 Output HIGH Voltage (LOS) Output LOW Voltage (LOS))
1 2
(Over Operating Case Temperature. VCC = 3.13 to 3.47V)) Symbol VPP-DIF VOH VOL Minimum 0.40 VCC - 1.3 0 Typical Maximum 1.75 VCC + 0.3 0.5 Units V V V
2 2
Differential peak-to-peak voltage across external 100Ω load. Open collector compatible, 4.7 to 10kΩ pull-up resistor to Vcc (Host Supply Voltage).
Electrical Power Supply Characteristics
Parameter Supply Voltage Supply Current VCC ICC
(Over Operating Case Temperature. VCC = 3.13 to 3.47V)) Minimum 3.13 Typical 3.3 Maximum 3.47 345 Units V mA
Symbol
Module Definition
MOD_DEF(0) pin 6 MOD_DEF(1) pin 5 MOD_DEF(2) pin 4 Interpretation by Host
TTL LOW
SCL
SDA
Serial module definition protocol
Electrical Pad Layout
20 19 18 17 16 15 14 13 12 11
TX GND TD- (TX DATA IN-) TD+ (TX DATA IN+) TX GND VccTX VccRX RX GND RD+ (RX DATA OUT+) RD- (RX DATA OUT-) RX GND
Host Board Connector Pad Layout
20 19 18 17 16 15 14 13 12 11
Toward ASIC
1 2 3 4 5 6 7 8 9 10
TX GND TX Fault TX Disable MOD_DEF(2) MOD_DEF(1) MOD_DEF(0) NO CONNECTION LOS RX GND RX GND
1 2 3
Toward Bezel
4 5 6 7 8 9 10
Top of Board
Bottom of Board (as viewed thru top of board)
Oplink Communications, Inc.
3
Rev7.2008.07.17
TRPW48L2/E2 DWDM
Example of SFP host board schematic
Vcc 3.3V
1μH coil or ferrite bead (