SPB-9840ARLWG

SPB-9840ARLWG

  • 厂商:

    OPTOWAY

  • 封装:

  • 描述:

    SPB-9840ARLWG - 1310 nm TX / 1490 nm RX , 3.3V / 3.2 Gb/s Digital Diagnostic Single-Fiber SFP Transc...

  • 详情介绍
  • 数据手册
  • 价格&库存
SPB-9840ARLWG 数据手册
Optoway SPB-9840RWG / SPB-9840BRWG / SPB-9840ARWG SPB-9840RLWG / SPB-9840BRLWG / SPB-9840ARLWG (SC BIDI SFP) (LC BIDI SFP) SPB-9840RWG (RoHS Compliant) 1 *********************************************************************************************************************************************************************** 1310 nm TX / 1490 nm RX , 3.3V / 3.2 Gb/s Digital Diagnostic Single-Fiber SFP Transceiver ********************************************************************************************************************************************************************** FEATURES DESCRIPTION l l l l l l l l l l l l l l l Multirate up to 3.2 Gb/s 1 -Fiber Bi-Directional SFP Optical Transceiver Simplex SC Connector: SPB-9840RWG Simplex LC Connector: SPB-9840RLWG SFF-8472 Digital Diagnostic Function 1310 nm DFB LD Transmitter 1490 nm Receiver D istance Up to 40 km AC/AC Coupling according to MSA Single +3.3 V Power Supply RoHS Compliant 0 to 70oC Operating: SPB-9840RWG -10 to 85oC Operating: SPB-9840BRWG -40 to 85oC Operating: SPB-9840ARWG Class 1 Laser International Safety Standard IEC 60825 Compliant The SPB-9840RWG series is high performance module for 10GBASE LX-4, Serial ATA/ATA2, SONET OC-48 / SDH STM-16, Gigabit Ethernet 1000BASE-LX and 1x/2x Fibre Channel single fiber communications by using 1310 nm transmitter and 1490 nm receiver. It is with the SFP 20-pin connector to allow hot plug capability. Digital diagnostic functions are available via an I2C. The transmitter section uses a multiple quantum well 1310 nm DFB laser and is a class 1 laser compliant according to International Safety Standard IEC 60825. The receiver section is designed to receive 1490 nm signal. The receiver section uses an integrated 1490 nm detector preamplifier (IDP) mounted in an optical header and a limiting post-amplifier IC. LASER SAFETY This single mode transceiver is a Class 1 laser product. It complies with IEC 60825 and FDA 21 CFR 1040.10 and 1040.11. The transceiver must be operated within the specified temperature and voltage limits. The optical ports of the module shall be terminated with an optical connector or with a dust plug. APPLICATIONS l l l l l l 10GBASE LX-4 Serial ATA / ATA2 SONET OC-48 / SDH STM-16 SONET OC-12 / SDH STM-4 SONET OC-3 / SDH STM-1 Gigabit Ethernet / 1X/2X Fibre Channel ORDER INFORMATION P/No. Bit Rate (Gb/s) Multirate* Multirate* Multirate* Distance (km) 40 40 40 40 40 40 TX (nm) 1310DFB 1310DFB 1310DFB 1310DFB 1310DFB 1310DFB RX (nm) 1490 1490 1490 1490 1490 1490 Package Temp (oC) SPB-9840RWG SPB-9840BRWG SPB-9840ARWG SC SFP with DMI 0 to 70 SC SFP with DMI -10 to 85 SC SFP with DMI -40 to 85 LC SFP with DMI 0 to 70 LC SFP with DMI -10 to 85 LC SFP with DMI -40 to 85 TX Power (dBm) 3 to -2 3 to -2 3 to -2 3 to -2 3 to -2 3 to -2 RX Sens. RoHS (dBm) Compliant -20 -20 -20 -20 -20 -20 Yes Yes Yes Yes Yes Yes SPB-9840RLWG Multirate* SPB-9840BRLWG Multirate* SPB-9840ARLWG Multirate* Multirate*: 3.185Gb/s, 3.125Gb/s, 2.67 Gb/s / OC-48 / 2X FC / GbE / 1X FC / OC-12 / OC-3 *********************************************************************************************************************************************************************** OPTOWAY TECHNOLOGY INC. No.38, Kuang Fu S. Road, Hu Kou, Hsin Chu Industrial Park, Hsin Chu, Taiwan 303 Tel: 886-3-5979798 Fax: 886-3-5979737 E-mail: sales@optoway.com.tw http: // www.optoway.com.tw 1 /1/2008 V1.0 Optoway Absolute Maximum Ratings Parameter Storage Temperature Operating Case Temperature Symbol Tstg Topr Min -40 0 -10 -40 0 0 GND 0 Max 85 70 85 85 85 3.6 Vcc 30 Units o C o C SPB-9840RWG Notes SPB-9840RWG SPB-9840BRWG SPB-9840ARWG Non condensing 2 ********************************************************************************************************************************************************************** Relative Humidity Power Supply Voltage Input Voltage Output Current RH Vcc --Iout % V V mA Recommended Operating Conditions Parameter Power Supply Voltage Power Supply Current Operating Case Temperature Symbol Vcc ICC (TX+RX) Topr Min 3.13 0 -10 -40 125 Typ 3.3 200 Max 3.47 300 70 85 85 3200 Units / Notes V mA o C / SPB-9840RWG o C / SPB-9840BRWG o C / SPB-9840ARWG Mb/s Data Rate 3125 Transmitter Specifications (0 oC < Topr < 70 oC, 3.13V < Vcc < 3. 47V) Parameter Symbol Min Typ Max Units Notes Optical Optical Transmit Power Po -2 3 dBm 1 Output Center Wavelength 1261 1360 nm λ Output Spectrum Width 1 nm -20 dB width σλ Side Mode Suppression Ratio SMSR 30 dB Extinction Ratio ER 8.2 dB Output Eye Compliant with Telecordia GR-253-GORE and ITU-T Recommendation G.957 Optical Rise Time tr 150 ps 20 % to 80% Values Optical Fall Time tf 150 ps 20 % to 80% Values Relative Intensity Noise RIN -120 dB/Hz Electrical Data Input Current – Low IIL -350 µA Data Input Current – High IIH 350 µA Differential Input Voltage VIH - VIL 0.5 2.4 V Peak-to-Peak TX Disable Input Voltage – Low TDIS, L 0 0.5 V 2 TX Disable Input Voltage – High TDIS, H 2.0 Vcc V 2 TX Disable Assert Time TASSERT 10 µs TX Disable Deassert Time T DEASSERT 1 ms TX Fault Output Voltage -- Low TFaultL 0 0.5 V 3 TX Fault Output Voltage -- High TFaultH 2.0 Vcc+0.3 V 3 Notes: 1. Output power is power coupled into a 9/125 µm single mode fiber. 2. There is an internal 4.7K to 10K ohm pull-up resistor to VccTX. 3. Open collector compatible, 4.7K to 10K ohm pull-up to Vcc (Host Supply Voltage). ********************************************************************************************************************************************************************* OPTOWAY TECHNOLOGY INC. No.38, Kuang Fu S. Road, Hu Kou, Hsin Chu Industrial Park, Hsin Chu, Taiwan 303 Tel: 886-3-5979798 Fax: 886-3-5979737 E-mail: sales@optoway.com.tw http: // www.optoway.com.tw 1/1/2008 V1.0 Optoway Receiver Specifications (0oC < Topr < 70oC, 3.13 V < Vcc < 3.47V) Parameter Optical Sensitivity Maximum Input Power Signal Detect -- Asserted Signal Detect -- Deasserted Signal detect -- Hysteresis Wavelength of Operation Electrical Differential Output Voltage Output LOS Voltage -- Low Output LOS Voltage – High Signal Detect Assert Time Signal Detect Deassert Time Symbol --Pin Pa Pd Min --0 ---31 1.0 1480 0.6 0 2.0 Typ ----------Max -20 ---20 --1500 2.0 0.5 Vcc+0.3 100 300 Units dBm dBm dBm dBm dB nm V V V µs µs SPB-9840RWG Notes 4 Transition: low to high Transition: high to low 5 3 ********************************************************************************************************************************************************************** VOH – VOL VOL V OH ASMAX ANSMAX 6 6 OFF to ON ON to OFF Notes: 4. Minimum sensitivity and saturation levels at BER 1E-10 for a 223-1 PRBS. 5. At least 30 dB optical isolation for the wavelength 1260 to 1360 nm. 6. Open collector compatible, 4.7K to 10K ohm pull-up to Vcc (Host Supply Voltage). RECOMMENDED CIRCUIT SCHEMATIC VeeT Tx_DISABLE T x_FAULT (1,17,20) 3 2 4.7K to 10KΩ TD + 18 Z=50Ω TD 19 Z=50Ω VccT 16 10nF 1μH Vcc 3.3V 10μF 10nF 1μH VccR 15 10nF 10μF 10μF TD TD + Tx_DISABLE Tx_FAULT LD Driver 100Ω SerDes IC Protocol IC RD - 12 Z=50Ω 100Ω RD - POST Amp RD + 13 Z=50Ω 4.7K to 10KΩ RD + depending on SERDES LOSS OF SINGAL LOS VeeR MOD_DEF(0) 8 (9,10,11,14) 6 5 4 4.7K to 10KΩ 4.7K to 10KΩ 4.7K to 10KΩ Vcc 3.3V MODULE DETECT SCL SDA EEPROM MOD_DEF(1) MOD_DEF(2) SFP module ********************************************************************************************************************************************************************* OPTOWAY TECHNOLOGY INC. No.38, Kuang Fu S. Road, Hu Kou, Hsin Chu Industrial Park, Hsin Chu, Taiwan 303 Tel: 886-3-5979798 Fax: 886-3-5979737 E-mail: sales@optoway.com.tw http: // www.optoway.com.tw 1/1/2008 V1.0 Optoway CONNECTION DIAGRAM SPB-9840RWG 4 ********************************************************************************************************************************************************************** PIN 1 2 3 4 5 6 7 8 9 10 Signal Name TX GND TX Fault TX Disable MOD-DFE2 MOD-DEF1 MOD-DEF0 N/C LOS RX GND RX GND Description Transmitter Ground Transmitter Fault Indication T ransmitter Disable (Module disables on high or open) Modulation Definition 2 – Two wires serial ID Interface Modulation Definition 1 – Two wires serial ID Interface Modulation Definition 0 – Ground in Module Not Connected Loss of Signal Receiver Ground Receiver Ground PIN 11 12 13 14 15 16 17 18 19 20 Signal Name Description RX GND Receiver Ground RX DATA OUT- Inverse Receiver Data Out RX DATA OUT+ Receiver Data Out RX GND Vcc RX Vcc TX TX GND TX DATA IN+ TX DATA INTX GND Receiver Ground Receiver Power – 3 .3V±5% Transmitter Power – 3 .3V±5% Transmitter Ground Transmitter Data In Inverse Transmitter Data In Transmitter Ground MODULE DEFINITION Module Definition 4 MOD-DEF2 PIN 4 SDA MOD-DEF1 PIN 5 SCL MOD-DEF0 PIN 6 LV-TTL Low Interpretation by Host Serial module definition protocol Module Definition 4 specifies a serial definition protocol. For this definition, upon power up, MOD-DEF(1:2) appear as no connector (NC) and MOD-DEF(0) is TTL LOW. When the host system detects this condition, it activates the serial protocol. The protocol uses the 2-wire serial CMOS E 2PROM protocol of the ATMEL AT24C01A/02/04 family of components. ********************************************************************************************************************************************************************* OPTOWAY TECHNOLOGY INC. No.38, Kuang Fu S. Road, Hu Kou, Hsin Chu Industrial Park, Hsin Chu, Taiwan 303 Tel: 886-3-5979798 Fax: 886-3-5979737 E-mail: sales@optoway.com.tw http: // www.optoway.com.tw 1/1/2008 V1.0 Optoway PACKAGE DIAGRAM Units in mm A) SC SFP SPB-9840RWG 5 ********************************************************************************************************************************************************************** B) LC SFP Note: Specifications subject to change without notice. ********************************************************************************************************************************************************************* OPTOWAY TECHNOLOGY INC. No.38, Kuang Fu S. Road, Hu Kou, Hsin Chu Industrial Park, Hsin Chu, Taiwan 303 Tel: 886-3-5979798 Fax: 886-3-5979737 E-mail: sales@optoway.com.tw http: // www.optoway.com.tw 1/1/2008 V1.0 Optoway REVISION HISTORY V ersion 1 .0 Initial datasheet SPB-9840RWG 6 ********************************************************************************************************************************************************************** Subject Release Date 2008/1/1 ********************************************************************************************************************************************************************* OPTOWAY TECHNOLOGY INC. No.38, Kuang Fu S. Road, Hu Kou, Hsin Chu Industrial Park, Hsin Chu, Taiwan 303 Tel: 886-3-5979798 Fax: 886-3-5979737 E-mail: sales@optoway.com.tw http: // www.optoway.com.tw 1/1/2008 V1.0
SPB-9840ARLWG
1. 物料型号: - SPB-9840RWG:1310 nm TX / 1490 nm RX,3.3V / 3.2 Gb/s Digital Diagnostic Single-Fiber SFP Transceiver,使用SC连接器。 - SPB-9840RLWG:与SPB-9840RWG类似,但使用LC连接器。 - 其他型号包括SPB-9840BRWG、SPB-9840ARWG、SPB-9840BRLWG、SPB-9840ARLWG,它们的主要区别在于工作温度范围。

2. 器件简介: - SPB-9840RWG系列是一款用于10GBASE LX-4、Serial ATA/ATA2、SONET OC-48/SDH STM-16等高速通信的高性能模块,使用1310 nm发射器和1490 nm接收器,支持单光纤通信。

3. 引脚分配: - TX GND:发射器地。 - RX GND:接收器地。 - TX Fault:发射器故障指示。 - TX Disable:发射器禁用。 - MOD-DFE2、MOD-DEF1、MOD-DEF0:模块定义引脚,用于模块定义协议。 - LOS:信号丢失。 - Vcc:电源。

4. 参数特性: - 支持高达3.2 Gb/s的多速率。 - 使用SFF-8472数字诊断功能。 - 1310 nm DFB LD发射器,1490 nm接收器,传输距离可达40公里。 - 符合国际安全标准IEC 60825。

5. 功能详解: - 该模块支持多种通信标准,包括10GBASE LX-4、Serial ATA/ATA2、SONET OC-48/SDH STM-16等。 - 发射器部分使用多量子阱1310 nm DFB激光器,接收器部分使用集成的1490 nm探测器前置放大器。

6. 应用信息: - 适用于10GBASE LX-4、Serial ATA/ATA2、SONET OC-48/SDH STM-16、SONET OC-12/SDH STM-4、SONET OC-3/SDH STM-1、Gigabit Ethernet和Fibre Channel等应用。

7. 封装信息: - 提供SC和LC两种接口的SFP封装,带有数字诊断接口(DMI)。 - 工作温度范围从0到70°C(SPB-9840RWG),-10到85°C(SPB-9840BRWG)和-40到85°C(SPB-9840ARWG)。
SPB-9840ARLWG 价格&库存

很抱歉,暂时无法提供与“SPB-9840ARLWG”相匹配的价格&库存,您可以联系我们找货

免费人工找货