0
登录后你可以
  • 下载海量资料
  • 学习在线课程
  • 观看技术视频
  • 写文章/发帖/加入社区
创作中心
发布
  • 发文章

  • 发资料

  • 发帖

  • 提问

  • 发视频

创作活动
F-51373GNC-FW-AH

F-51373GNC-FW-AH

  • 厂商:

    OPTREX(京瓷)

  • 封装:

    -

  • 描述:

    LCD GRAPHIC MOD COLOR 240X320

  • 数据手册
  • 价格&库存
F-51373GNC-FW-AH 数据手册
First Edition May 7, 2003 LCD Module Technical Specification Final Revision ****** Type No. F-51373GNC-FW-AH Approved by (Quality Assurance Division) ) Checked by (ACI Engineering Division) ) Prepared by (Module Administration Group) Table of Contents 1. General Specifications .................................................................................................................................. 2 2. Electrical Specifications ............................................................................................................................... 3 3. Optical Specifications ................................................................................................................................... 9 4. I/O Terminal .................................................................................................................................................... 11 5. Test ................................................................................................................................................................... 13 6. Appearance Standards ............................................................................................................................... 14 7. Code System of Production Lot ............................................................................................................... 17 8. Type Number.................................................................................................................................................. 17 9. Applying Precautions .................................................................................................................................. 17 10. Precautions Relating Product Handling................................................................................................ 18 11. Warranty ........................................................................................................................................................ 19 Revision History Rev. Date Page F-51373GNC-FW-AH (AH) No. 2003-0066 Comment OPTREX CORPORATION Page 1/19 1. General Specifications Operating Temp. : min. 0°C ~max. 50°C Storage Temp. : min. -20°C ~max. 70°C Dot Pixels : 240×3 [R.G.B] (W) × 320 (H) dots Dot Size : 0.070 (W) × 0.225 (H) mm Dot Pitch : 0.24 (W) × 0.24 (H) mm Viewing Area : 59.0 (W) × 80.3 (H) mm Outline Dimensions : 73.0 (W) × 94.4* (H) × 7.3max. (D) mm * Without CFL Cable Weight : 62.8g max. LCD Type : CTD-21398 ( F-STN / Color-mode / Transmissive ) Viewing Angle : 6:00 Data Transfer : 8-bit parallel data transfer Backlight : Cold Cathode Fluorescent Lamp (CFL) × 1 Drawings : Dimensional Outline F-51373GNC-FW-AH (AH) No. 2003-0066 UE-310580C OPTREX CORPORATION Page 2/19 2. Electrical Specifications 2.1. Absolute Maximum Ratings VSS=0V Parameter Symbol Conditions Min. Max. Units Supply Voltage VCC -V SS - -0.3 7.0 V VLCD-V SS - -0.3 30.0 V VI - -0.3 VCC +0.3 V (Logic) Supply Voltage (LCD Drive) Input Voltage 2.2. DC Characteristics Ta=25°C, VSS=0V Parameter Symbol Conditions Min. Typ. Max. Units Supply Voltage VCC -V SS - 2.7 - 5.5 V (Logic) Supply Voltage VLCD-V SS Shown in 3.1 V (LCD Drive) High Level VIH VCC =2.7~5.5V 0.8×VCC - - V VOH IOH =-0.4mA VCC-0.4 - - V VIL VCC =2.7~5.5V 0 - 0.2×VCC V VOL IOH =0.4mA - - 0.4 V ICC VCC -V SS=4.1V - 0.4 0.6 mA ILCD VLCD-V SS=23.6V - 3.7 5.5 mA Input Voltage High Level output Voltage Low Level Input Voltage Low Level output Voltage Supply Current F-51373GNC-FW-AH (AH) No. 2003-0066 OPTREX CORPORATION Page 3/19 2.3. AC Characteristics VCC =4.5~5.5V Parameter Shift Clock Period Shift Clock “H” Pulse Width Shift Clock “L” Pulse Width Data Setup Time Data Hold Time Latch Pulse “H” Pulse Width Shift Clock Rise to Latch Pulse Rise Time Shift Clock Fall to Latch Pulse Fall Time Latch Pulse Rise to Shift Clock Rise Time Latch Pulse Fall to Shift Clock Rise Time Input Signal Rise,Fall Time DISPOFF Removal Time DISPOFF Enable Pulse Width Output Delay Time Symbol Min. Max. Units tWCK tWCKH tWCKL tDS tDH tWLPH tLD tSL tLS tLH tr, tf tSD tWDL tDL 50 - ns 15 - ns 15 - ns 10 - ns 12 - ns 15 - ns 0 - ns 30 - ns 25 - ns 25 - ns - 50 Note.1 ns 100 - ns 1.2 - µs - 200 Note.2 ns Note.1 : (tCK – twckll - twckl)/2 is the maximum in case of high speed operation. Note.2 : CL=15pF VCC =3.0~4.5V Parameter Shift Clock Period Shift Clock “H” Pulse Width Shift Clock “L” Pulse Width Data Setup Time Data Hold Time Latch Pulse “H” Pulse Width Shift Clock Rise to Latch Pulse Rise Time Shift Clock Fall to Latch Pulse Fall Time Latch Pulse Rise to Shift Clock Rise Time Latch Pulse Fall to Shift Clock Rise Time Input Signal Rise,Fall Time DISPOFF Removal Time DISPOFF Enable Pulse Width Output Delay Time Symbol Min. Max. Units tWCK tWCKH tWCKL tDS tDH tWLPH tLD tSL tLS tLH tr, tf tSD tWDL tDL 66 - ns 23 - ns 23 - ns 15 - ns 23 - ns 30 - ns 0 - ns 50 - ns 30 - ns 30 - ns - 50 Note.1 ns 100 - ns 1.2 - µs - 200 Note.2 ns Note.1 : (tCK – twckll - twckl)/2 is the maximum in case of high speed operation. Note.2 : CL=15Pf F-51373GNC-FW-AH (AH) No. 2003-0066 OPTREX CORPORATION Page 4/19 VCC =2.7~3.0V Parameter Shift Clock Period Shift Clock “H” Pulse Width Shift Clock “L” Pulse Width Data Setup Time Data Hold Time Latch Pulse “H” Pulse Width Shift Clock Rise to Latch Pulse Rise Time Shift Clock Fall to Latch Pulse Fall Time Latch Pulse Rise to Shift Clock Rise Time Latch Pulse Fall to Shift Clock Rise Time Input Signal Rise,Fall Time DISPOFF Removal Time DISPOFF Enable Pulse Width Output Delay Time Symbol Min. Max. Units tWCK tWCKH tWCKL tDS tDH tWLPH tLD tSL tLS tLH tr, tf tSD tWDL tDL 82 - ns 28 - ns 28 - ns 20 - ns 23 - ns 30 - ns 0 - ns 65 - ns 30 - ns 30 - ns - 50 Note.1 ns 100 - ns 1.2 - µs - 200 Note.2 ns Note.1 : (tCK – twckll - twckl)/2 is the maximum in case of high speed operation. Note.2 : CL=15pF FLM tDL t WLPH LP t SL t LD t LS t LH t WCKL t WCKH CP tr tf t WCK D0~D7 t DS LAST DATA t WDL t DH TOP DATA t SD DISPOFF F-51373GNC-FW-AH (AH) No. 2003-0066 OPTREX CORPORATION Page 5/19 2.4. Timing Chart T=0.04464ms typ. LP CP D0 SEG D7 705 ~ 712 SEG 713~ 720 SEG SEG 1~ 8 9~ 16 SEG #1 DATA 705~ 712 SEG 713 ~ 720 SEG SEG 1~ 8 9~ 16 FLM LP (Reduction) 320xT FLM (Reduction) 2.5. Comparison of Display and Data SEG720 SEG1 #1 D7 D6 D5 D0 TOP VIEW D0~D7 #320 F-51373GNC-FW-AH (AH) No. 2003-0066 OPTREX CORPORATION Page 6/19 2.6. Power Supply ON/OFF Sequence 2.6.1. ON Sequence SIGNAL LEVEL VCC VCC VSS 0≤ t VCC SIGNAL VSS 0≤ t VLCD VLCD VSS 0≤ t VCC DISPOFF VSS 2.6.2. OFF Sequence LEVEL SIGNAL VCC VSS VCC 0≤ t VCC VSS SIGNAL 0≤ t VLCD VSS VCC VLCD 0≤ t VSS DISPOFF Please maintain the above sequence when turning on and off the power supply of the module. If DISPOFF is supplied to the module while internal alternate signal for LCD driving (M) is unstable, DC component will be supplied to the LCD panel. This may cause damage the LCD module. F-51373GNC-FW-AH (AH) No. 2003-0066 OPTREX CORPORATION Page 7/19 2.7. Lighting Specifications Ta=25°C Parameter Symbol Conditions Min. Typ. Max. Units Notes Lamp Voltage VL - - 280 - Vrms 1 Lamp Current IL - 2.0 3.0 4.0 mArms 2 VS - - - 500 Vrms 3 2 4 Starting Voltage Surface Luminance L IL=3.0mA - 2000 - cd/m TAL IL=3.0mA - 50,000 - hrs 5 Parameter Symbol Conditions Min. Typ. Max. Units Notes Luminance of Module L IL=3.0mA 70 90 - cd/m2 4 Average Life Note 1 :The voltage ( r.m.s. ) to maintain the electric discharge of the lamp. It is measured after lighting for 3 minutes . Note 2 :The current ( r.m.s. ) to flow through the lamp with the electric discharge. It is measured after lighting for 3 minutes. Note 3 :The voltage at starting the electric discharge when the voltage is increased gradually from 0V. Note 4 :Surface Luminance is specified by the initial data of luminance measured at the center of display surface after 20 minutes power on. ( All ON pattern ) Note 5 : CFL Life is defined as time period that the actual luminance becomes 50% or lower of its initial value. The Average life time of CFL is defined as the time when half or more of the testing CFLs have become less bright than 50% of the initial brightness at continuous operation. I N C VS VL V F L IL CFL Testing Circuit F-51373GNC-FW-AH (AH) No. 2003-0066 OPTREX CORPORATION Page 8/19 3. Optical Specifications 3.1. LCD Driving Voltage Parameter Symbol Recommended LCD Driving Voltage VLCD-V SS Note 1 Conditions Min. Typ. Max. Units Ta= 0°C - - 26.1 V Ta=25°C 22.5 24.2 25.9 V Ta=50°C 21.9 - - V Note 1 : Voltage (Applied actual waveform to LCD Module) for the best contrast. The range of minimum and maximum shows tolerance of the operating voltage. The specified contrast ratio and response time are not guaranteed over the entire range. 3.2. Optical Characteristics Ta=25°C, 1/320 Duty, 1/15 Bias, VOD =24.2V (Note 4), θ= 0°, φ=270° Parameter Contrast Ratio Note 1 Symbol Conditions Min. Typ. Max. CR θ= 0°C , φ=270° - 45 - Viewing Angle Response Time Units Shown in 3.3 Rise Note 2 TON - - 400 600 ms Decay Note 3 TOFF - - 250 380 ms Note 1 :Contrast ratio is definded as follows. (CR = LON / LOFF) LON : Luminance of the ON segments LOFF: Luminance of the OFF segments Measuring Spot : 3.0mmφ Note 2 :The time that the luminance level reaches 90% of the saturation level from 0% when ON signal is applied. Note 3 :The time that the luminance level reaches 10% of the saturation level from 100% when OFF signal is applied. Note 4 :Definition of Driving Voltage VOD Assuming that the typical driving waveforms shown below are applied to the LCD Panel at 1/A Duty - 1/B Bias (A: Duty Number, B: Bias Number). Driving voltage VOD is definded as the voltage VO-P when the contrast ratio (CR=LON / LOFF) is at its maximum. VO-P ( B-2 )×VO-P / B 1 / ( f F× A ) F-51373GNC-FW-AH (AH) No. 2003-0066 1 / fF OPTREX CORPORATION Page 9/19 3.3. Definition of Viewing Angle and Optimum Viewing Area *Point • shows the point where contrast ratio is measured. : θ= 0°, φ=270° *Driving condition: 1/320 Duty, 1/15 Bias, VOD =24.2V, fF =70Hz 90° 45° 135° θ φ 180° 10 20 30 40 50 90° ( φ = 0°) θ φ 180° 225° 0° 315° 270° 270° *Area   shows typ. CR≥5 (Measuring Spot : 3.0mmφ) 3.4. System Block Diagram Temperature Chamber Rotation Table ( θ,φ ) Photometer #1980A WB φ LCD Optical Fiber θ Computer Control Unit & Waveform Generator Halogen bulb F-51373GNC-FW-AH (AH) No. 2003-0066 OPTREX CORPORATION Page 10/19 4. I/O Terminal 4.1. Pin Assignment CN1 No. Symbol Function 1 VSS Power Supply (0V, GND) 2 VSS Power Supply (0V, GND) 3 FLM First Line Marker 4 LP Data Latch Signal 5 CP Clock Signal for Shifting Data 6 DISPOFF 7 D7 Display Data 8 D6 Display Data 9 D5 Display Data 10 D4 Display Data 11 VCC 12 D3 Display Data 13 D2 Display Data 14 D1 Display Data 15 D0 Display Data 16 VSS Power Supply (0V, GND) 17 VLCD Power Supply for LCD Drive 18 NC Non-connection 19 NC Non-connection 20 NC Non-connection 21 NC Non-connection 22 VSS Power Supply (0V, GND) Display Control Signal H : Display on L : Display off Power Supply for Logic CN2 No. Symbol Function 1 H.V Power Supply for CFL (HOT) 2 NC Non-connection 3 GND Power Supply for CFL (GND) F-51373GNC-FW-AH (AH) No. 2003-0066 OPTREX CORPORATION Page 11/19 4.2. Example of Power Supply It is recommended to apply a potentiometer for the contrast adjust due to the tolerance of the driving voltage and its temperature dependence. VLCD VLCD(+Voltage) R1 Tr VR MODULE R2 VSS VSS (0V) VCC VCC (+Voltage) R1+R2+VR=10~ 20 KΩ 4.3. Block Diagram Row Driver NT7703 × 2 or equivalent FLM 320 LCDP 240(RGB) × 320 dots 720 LP Column Driver NT7704 × 3 or equivalent DISPOFF CP 8 D0~D7 M Circuit VLCD VCC Bias Circuit To LSI VSS H.V CFL Backlight GND F-51373GNC-FW-AH (AH) No. 2003-0066 OPTREX CORPORATION Page 12/19 5. Test No change on display and in operation under the following test condition. Conditions: No. Unless otherwise specified, tests will be conducted under the following condition. Temperature: 20±5°C Humidity : 65±5%RH tests will be not conducted under functioning state. Parameter Conditions Notes 1 High Temperature Operating 50°C±2°C, 96hrs (operation state) 2 Low Temperature Operating 0°C±2°C, 96hrs (operation state) 1 3 High Temperature Storage 70°C±2°C, 96hrs 2 4 Low Temperature Storage -20°C±2°C, 96hrs 1,2 5 Damp Proof Test 40°C±2°C,90~95%RH, 96hrs 1,2 6 Vibration Test Total fixed amplitude : 1.5mm 3 Vibration Frequency : 10~55Hz One cycle 60 seconds to 3 directions of X, Y, Z for each 15 minutes 7 Shock Test To be measured after dropping from 60cm high on the concrete surface in packing state. Dropping method corner dropping F E G B D A corner : once Edge dropping C A 60cm B,C,D edge : once Face dropping E,F,G face : once Concrete Surface Note 1 :No dew condensation to be observed. Note 2 :The function test shall be conducted after 4 hours storage at the normal Temperature and humidity after removed from the test chamber. Note 3 :Vibration test will be conducted to the product itself without putting it in a container. F-51373GNC-FW-AH (AH) No. 2003-0066 OPTREX CORPORATION Page 13/19 6. Appearance Standards 6.1. Inspection conditions The LCD shall be inspected under 40W white fluorescent light. The distance between the eyes and the sample shall be more than 30cm. All directions for inspecting the sample should be within 45°against perpendicular line. 45° 6.2. Definition of applicable Zones A Zone Bezel Flame B Zone C Zone A Zone : Active display area B Zone : Area from outside of "A Zone" to validity viewing area C Zone : Rest parts A Zone + B Zone = Validity viewing area F-51373GNC-FW-AH (AH) No. 2003-0066 OPTREX CORPORATION Page 14/19 6.3. Standards No. 1 Parameter Black and Criteria (1) Round Shape White Spots, Foreign Substances Zone Acceptable Number Dimension (mm) A B C D ≤ 0.1 * * * 0.1 < D ≤ 0.2 3 5 * 0.2 < D ≤ 0.25 2 3 * 0.25< D ≤ 0.3 0 1 * 0.3 < D 0 0 * D = ( Long + Short ) / 2 * : Disregard (2) Line Shape Zone X (mm) Acceptable Number Y (mm) A B C - 0.03 ≥ W * * * 2.0 ≥ L 0.05 ≥ W 3 3 * 1.0 ≥ L 0.1 ≥ W 3 3 * - 0.1 < W X : Length Y : Width In the same way (1) * : Disregard Total defects shall not exceed 5. 2 Air Bubbles (between glass & polarizer) Zone Dimension (mm) Acceptable Number A B C D ≤ 0.3 * * * 0.3 < D ≤ 0.4 3 * * 0.4 < D ≤ 0.6 2 3 * 0.6 < D 0 0 * * : Disregard Total defects shall not exceed 3. F-51373GNC-FW-AH (AH) No. 2003-0066 OPTREX CORPORATION Page 15/19 No. 3 Parameter The Shape of Dot Criteria (1) Dot Shape (with Dent) 0.15 ≥ As per the sketch of left hand. (2) Dot Shape (with Projection) Should not be connected to next dot. (3) Pin Hole X (X+Y) / 2 ≤ 0.2mm Y (Less than 0.1mm is no counted.) (4) Deformation (X+Y) / 2 ≤ 0.2mm Y X Total acceptable number : 1/dot, 5/cell (Defect number of (4) : 1pc.) 4 Polarizer Scratches Not to be conspicuous defects. 5 Polarizer Dirts If the stains are removed easily from LCDP surface, the module is not defective. 6 7 Complex Foreign Black spots, line shaped foreign substances or air bubbles between Substance Defects glass & polarizer should be 5pcs maximum in total. Distance between D ≤ 0.2 : 20mm or more Different Foreign 0.2 < D : 40mm or more Substance Defects F-51373GNC-FW-AH (AH) No. 2003-0066 OPTREX CORPORATION Page 16/19 7. Code System of Production Lot The production lot of module is specified as follows. Factory Control Number (0~9) Date of the week (A~G) Factory Number (0~9) Factory Code (Alphabet) Production Week (1~5) Production Month (1~9, X, Y, Z) Production Year (Lower 2 digits) 8. Type Number The type number of module is specified as follows. F-51373GNC-FW-AH 9. Applying Precautions Please contact us when questions and/or new problems not specified in this Specifications arise. F-51373GNC-FW-AH (AH) No. 2003-0066 OPTREX CORPORATION Page 17/19 10. Precautions Relating Product Handling The Following precautions will guide you in handling our product correctly. 1) Liquid crystal display devices 1. The liquid crystal display device panel used in the liquid crystal display module is made of plate glass. Avoid any strong mechanical shock. Should the glass break handle it with care. 2. The polarizer adhering to the surface of the LCD is made of a soft material. Guard against scratching it. 2) Care of the liquid crystal display module against static electricity discharge. 1. When working with the module, be sure to ground your body and any electrical equipment you may be using. We strongly recommend the use of anti static mats ( made of rubber ), to protect work tables against the hazards of electrical shock. 2. Avoid the use of work clothing made of synthetic fibers. We recommend cotton clothing or other conductivity-treated fibers. 3. Slowly and carefully remove the protective film from the LCD module, since this operation can generate static electricity. 3) When the LCD module alone must be stored for long periods of time: 1. Protect the modules from high temperature and humidity. 2. Keep the modules out of direct sunlight or direct exposure to ultraviolet rays. 3. Protect the modules from excessive external forces. 4) Use the module with a power supply that is equipped with an overcurrent protector circuit,since the module is not provided with this protective feature. 5) Do not ingest the LCD fluid itself should it leak out of a damaged LCD module. Should hands or clothing come in contact with LCD fluid, wash immediately with soap. 6) Conductivity is not guaranteed for models that use metal holders where solder connections between the metal holder and the PCB are not used. Please contact us to discuss appropriate ways to assure conductivity. 7) For models which use CFL: 1. High voltage of 1000V or greater is applied to the CFL cable connector area. Care should be taken not to touch connection areas to avoid burns. 2. Protect CFL cables from rubbing against the unit and thus causing the wire jacket to become worn. 3. The use of CFLs for extended periods of time at low temperatures will significantly shorten their service life. 8) For models which use touch panels: 1. Do not stack up modules since they can be damaged by components on neighboring modules. 2. Do not place heavy objects on top of the product. This could cause glass breakage. 9) For models which use COG,TAB,or COF: 1. The mechanical strength of the product is low since the IC chip faces out unprotected from the rear. Be sure to protect the rear of the IC chip from external forces. 2. Given the fact that the rear of the IC chip is left exposed, in order to protect the unit from electrical damage, avoid installation configurations in which the rear of the IC chip runs the risk of making any electrical contact. F-51373GNC-FW-AH (AH) No. 2003-0066 OPTREX CORPORATION Page 18/19 10) Models which use flexible cable, heat seal, or TAB: 1. In order to maintain reliability, do not touch or hold by the connector area. 2. Avoid any bending, pulling, or other excessive force, which can result in broken connections. 11) have an adverse effect on connecting parts ( LCD panel-TCP / HEAT SEAL / FPC / etc., PCB-TCP / HEAT SEAL / FPC etc., TCP-HEAT SEAL, TCP-FPC, HEAT SEAL-FPC, etc.,) depending on its materials. Please check and evaluate these materials carefully before use. 12) In case of acrylic plate is attached to front side of LCD panel, cloudiness ( very small cracks ) can occur on acrylic plate, being influenced by some components generated from polarizer film.. Please check and evaluate those acrylic materials carefully before use. 11. Warranty This product has been manufactured to your company’s specifications as a part for use in your company’s general electronic products. It is guaranteed to perform according to delivery specifications. For any other use apart from general electronic equipment, we cannot take responsibility if the product is used in medical devices, nuclear power control equipment, aerospace equipment, fire and security systems, or any other applications in which there is a direct risk to human life and where extremely high levels of reliability are required. If the product is to be used in any of the above applications, we will need to enter into a separate product liability agreement. 1. We cannot accept responsibility for any defect, which may arise from additional manufacturing of the product (including disassembly and reassembly), after product delivery. 2. We cannot accept responsibility for any defect, which may arise after the application of strong external force to the product. 3. We cannot accept responsibility for any defect, which may arise due to the application of static electricity after the product has passed your company’s acceptance inspection procedures. 4. When the product is in CFL models, CFL service life and brightness will vary According to the performance of the inverter used, leaks, etc. We cannot accept responsibility for product performance, reliability, or defect, which may arise. 5. We cannot accept responsibility for intellectual property of a third party, which may arise through the application of our product to your assembly with exception to those issues relating directly to the structure or method of manufacturing of our product. 6. Optrex will not be held responsible for any quality guarantee issue for defect products judged as Optrex-origin longer than 2 (two) years from Optrex production or 1(one) year from Optrex, Optrex America, Optrex Europe delivery which ever comes later. F-51373GNC-FW-AH (AH) No. 2003-0066 OPTREX CORPORATION Page 19/19
F-51373GNC-FW-AH 价格&库存

很抱歉,暂时无法提供与“F-51373GNC-FW-AH”相匹配的价格&库存,您可以联系我们找货

免费人工找货