Data Sheet
LINEARlight Flex
LM10A
Benefits
Picture for Datasheet is missing !!!
Technical Operating Data
Product Color Number of LEDs 600 600 600 600 600 600 600 600 600 600 600 Voltage [V DC]* 24 24 24 24 24 24 24 24 24 24 24
Linear separable LED strip on flexible printed circuit board with self-adhesive back Low profile Available in various colors Minimal heat generation Applications Edge-lighting of transparent or diffused materials Path & contour marking Illuminated signs
Power [W]* 86,4 57,6 86,4 57,6 86,4 57,6 86,4 72,0 72,0 72,0 72,0
Current [A]* 3,6 2,4 3,6 2,4 3,6 2,4 3,6 3 3 3 3
Radiance Angle [°]* 120 120 120 120 120 120 120 120 120 120 120
Wavelength [nm] Color Temp [K]* 6500 K 6500 K 5400 K 5400 K 4700 K 4700 K 2700 K 617 nm 587 nm 525 nm 470 nm
Lum. Flux [lm]* 1290 540 1290 540 1290 540 1440 1620 1290 1200 170
LM10A-W2-865 white LM10A-W1-865 white LM10A-W2-854 white LM10A-W1-854 white LM10A-W2-847 white LM10A-W1-847 white LM10A-W3-727 white LM10A-A1 red LM10A-Y1 yellow LM10A-T2 green LM10A-B1 blue *) All Data are related to the entire module
Due to the special conditions of the manufacturing processes of LED the typical data of technical parameters can only reflect statistical figures and do not necessarily correspond to the actual parameters of each single product which could differ from the typical data. +) Preliminary Data
Technical Features
One reel comes with one LED-band Light emission vertical to the mounting surface Entire Module consists of 600 LEDs Size of printed circuit board (L x W x H): 8400 mm x 10 mm x 3 mm Size of smallest unit 10 LED (L x W): 140 mm x 10 mm Smallest unit of 10 LEDs can be cut out at regular intervals without damaging the rest of the module Adhesive tape on backside Easy connection with CONNECTsystem LM-xx Flex: Feeder LM-2PIN Flex and Connector LM-CONN-10 Flex Dimmable by pulse width modulation (PWM) with the electronic controller OT DIM Only parallel connection allowed Modules optimized for use with OSRAM OPTOTRONIC® power supplies.
LM10A - 20.07.2007
Page 1 of 4
Minimum and Maximum Ratings
Product LM10A-W2-865 LM10A-W1-865 LM10A-W2-854 LM10A-W1-854 LM10A-W2-847 LM10A-W1-847 LM10A-W3-727 LM10A-A1 LM10A-Y1 LM10A-T2 LM10A-B1 *) Operating Temperature at Tc-Point [ °C ] * -30 ... 75 -30 ... 75 -30 ... 75 -30 ... 75 -30 ... 75 -30 ... 75 -30 ... 75 -30 ... 85 -30 ... 85 -30 ... 75 -30 ... 75 Storage Temperature [ °C ] * -40 ... 85 -40 ... 85 -40 ... 85 -40 ... 85 -40 ... 85 -40 ... 85 -40 ... 85 -40 ... 85 -40 ... 85 -40 ... 85 -40 ... 85 Voltage Range [ V dc ] * 23 ... 25 23 ... 25 23 ... 25 23 ... 25 23 ... 25 23 ... 25 23 ... 25 23 ... 25 23 ... 25 23 ... 25 23 ... 25 Reverse Voltage [ V dc ] * 25 25 25 25 25 25 25 25 25 25 25
Exceeding maximum ratings for operating and storage temperature will reduce expected life time or destroy the LED Module. Exceeding maximum ratings for operating voltage will cause hazardous overload and will likely destroy the LED Module. The temperature of the LED module must be measured at the Tc-point according to EN60598-1 in a thermally constant status with a temperature sensor or a temperature sensitive label. For exact location of the Tc-point see drawing below.
Drawing
Drawing is missing !!!
LM10A - 20.07.2007
Page 2 of 4
Safety Information
The LED module itself and all its components must not be mechanically stressed. Assembly must not damage or destroy conducting paths on the circuit board.
The LED Module incorporates no protection against short circuits, overload or overheating. Therefore it is absolutely necessary to operate the modules with a electronically stabilised power supply offering protection against the above mentioned safety risks. For dimming applications attention should be paid to specific references in "OPTOTRONIC ® Technical Guide".
OSRAM OPTOTRONIC ® power supplies are specifically designed with protection features for safe operation.
W hen using power supplies other than OPTOTRONIC ® the following basic safety features are required, in addition to any other application specific concerns and local safety codes: Short circuit protection Overload protection Overheat protection Installation of LED modules (with power supplies) needs to be made with regard to all applicable electrical and safety standards. Only qualified personnel should be allowed to perform installations. Correct electrical polarity needs to be observed. Wrong polarity will result in no light emission. Parallel connection is highly recommended as safe electrical operation mode. Serial connection is not recommended. Unbalanced voltage drop can cause hazardous overload and damage the LED module. Please ensure that the power supply is of adequate power to operate the total load. The maximum current of 3 A for the module or its subunits is not be exeeded. W hen mounting on metallic or otherwise conductive surfaces, there needs to be a electrical isolation at soldering points between module and the mounting surface. The maximum length of LINEARlight Flex LM10A is 4200 mm (3500 mm for "W2" and "W3") with power feed at one end. The complete module 8400 mm can be operated with a two pole power feed in the middle of the module or from both ends, when only one power supply is used ("W2" / "W3" are limited to 7000 mm). Pay attention to standard ESD precautions when installing the module. The module, as manufactured, has no conformal coating and therefore offers no inherent protection against corrosion. The ability to customize the length of the module by cutting at specifically marked points is a key feature of the product and hence the reason for no factory installed conformal coating. For these reasons, it is recommended that the user complete all module modifications first (cutting, wiring) and then apply a conformal coating in the final stages of installation. Damage by corrosion will not be honored as a materials defect claim. It is the user´s responsibility to provide suitable protection against corrosive agents such as moisture and condensation and other harmful elements. For applications involving exposure to humidity and dust the module must be protected by a fixture or housing with a suitable protection class. The module can be protected against condensation water by treatment with an appropriate circuit board grade conformal coating. The conformal coating should have the following features: - Optical transparency - UV-resistance - thermal expansion matching the thermal expansion of the module 15-30*10^-6 cm/cm/K - low permeability of steam for all climatic conditions - resistance against corrosive environment The lacquer APL of the company Electrolube http://www.electrolube.com met the conditions for the LINEARlight Flex in our tests.
LM10A - 20.07.2007
Page 3 of 4
Assembly Information
Connection with soldering wires on unmounted module: Do not pretin the solderpads but pretin the wires and solder for max 4 s at 300 °C. Allow solderpoints to completely cool down before the next soldering. Prevent shear- or peel forces. Soldering of wires with the module mounted on a heatsink: Pretin solderpads and wires and solder for max 3 s at 350 °C. Allow solderpoints to completely cool down before the next soldering. Prevent shear- or peel forces. The smallest unit (140 mm- 10 LEDs) can be removed by cutting with scissors between the designated solder pads. The mounting of the module is facilitated by means of the double-sided adhesive on the back-surface of the module. Care must be taken to provide a clean and dry mounting surface, free of oils or silicone coatings as well as dirt particle. The mounting substrate must have sufficient structural integrity. Take care to completely remove the protective backing. Once the module is appropriately positioned, press on the module with about 20N/cm² (refer to application techniques of 3M adhesive transfer tapes). In difficult cases the use of a primer may help. The minimum bending radius is 2 cm. The module may be bent over a smaller radius but only in regions of the circuit board containing no electronic components and such bends should be made once and fixed in position to avoid cyclic fatigue. The thermal length expansion coefficient of the modul is 17*10^-6cm/cm/K. When installing in environments with large variations in temperature (e.g. outdoor applications) and operating length of more than 2 m, the use of metallic mounting surfaces is necessary. Otherwise it is advisable to use an additional thicker adhesive tape to absorb the stress of any mismatch in expansion coefficients.
Ordering Guide
Productgroup LINEARlight Flex LINEARlight Flex LINEARlight Flex LINEARlight Flex LINEARlight Flex LINEARlight Flex LINEARlight Flex LINEARlight Flex LINEARlight Flex LINEARlight Flex LINEARlight Flex
*) EAN: Ordering number per single module S-Unit: Modules per shipping unit
Productname LM10A-W2-865 LM10A-W1-865 LM10A-W2-854 LM10A-W1-854 LM10A-W2-847 LM10A-W1-847 LM10A-W3-727 LM10A-A1 LM10A-Y1 LM10A-T2 LM10A-B1
EAN * 4050300887265 4050300873817 4050300887289 4050300817170 4008321040145 4050300817156 4008321186171 4008321040060 4050300946030 4008321168832 4050300945491
S-Unit * 8 8 8 8 8 8 8 8 8 8 8
Note: Typical performance data are subject to change without any further notice, particularly as LED technology evolves.
Sales and Technical Support
OSRAM GmbH Hellabrunner Strasse 1 D - 81536 München Germany www.osram.com +49 (0)89 6213-0 Sales and technical support is given by the local OSRAM subsidiaries. On our world wide homepage all OSRAM subsidiaries are listed with complete address and phone numbers.
Related and Further Information
The new dimension of light New creativity in lighting design LED Modules for illuminated signs OPTOTRONIC® Technical Guide OPTOTRONIC® Data Sheets OSRAM LED systems Datasheet CONNECTsystem LM-xx Flex LM10A - 20.07.2007 153 S006 GB 138 W002 GB 130 T008 GB http://catalog.myosram.com www.osram.com/led-systems www.osram.com/led-systems-downloads Page 4 of 4
很抱歉,暂时无法提供与“LM10A-Y1”相匹配的价格&库存,您可以联系我们找货
免费人工找货